Search NASA⌕ Search

SEARCH · Search NASA

Results for “LOSSES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,765 records · Page 98

A Low Loss, Fast Ramp HTS Solenoid Prototype for Compact Spherical Tokamaks

To explore AC loss characteristics of commercial Bi-2212 conductors made in the USA, a small ohmic heating (OH) prototype coil is being developed for compact tokamaks using high performance Bi-2212 wires newly manufactured by Bruker EST. Here, the goal is to build and test Bi-2212 prototype coils for fast ramp central solenoid (CS) operation of spherical tokamaks (ST). For a ST pilot plant, one of the key challenges is the tight space available for CS in a center column where in-board legs of the toroidal field (TF) and OH coils are assembled into a cryostat with a few millimeters clearance. A high current density Rutherford cable consisting of 17 legacy Bi-2212 wires, a contribution of the US Magnet Development Program (MDP), was fabricated at the Lawrence Berkeley National Laboratory (LBNL) for the development of fast ramp CS magnets in the ST Advanced Reactor (STAR) designed by PPPL. Characterization of the new and legacy HTS wires is presented, along with the coil design wound directly with new wire, and a Rutherford cable-wound solenoid using the legacy wire. A comparison of AC losses is made based on expected performance for a fast ramp ST operation. The HTS cable and cabled coil fabrication issues such as the heat treatment, coil mandrel design, assembly and 2212 quench characteristics are discussed, along with a test plan for CS design validation.

Zhai, Yuhu [Princeton Plasma Physics Laboratory (P↗

Evaluating the Loss of Communications in Distribution Protection Systems using GridLAB-D

Protection in distribution systems is vital for maintaining reliability and ensuring proper power quality is provided to the end-use customer. As more switching devices are deployed on distribution systems, traditional protection schemes are giving way to more advanced, and sometimes centrally coordinated, protection schemes that rely on communications infrastructure. With these communications-dependent systems, the behaviors of the protection with and without the communications infrastructure must be examined. This work has evaluated the impacts of loss of communication in centrally coordinated protection schemes. Two test cases were examined: a sequence of similar faults on a feeder before and after a topology reconfiguration, and a feeder with a photovoltaic (PV) fault current contribution. Both simulations are run in the GridLAB-D™ simulation environment. A simple connectivity model is used to represent communication status. The results reveal that a failure of the communication system can cause significantly different protection behavior. This analysis can be used as a basis for utility engineers to make an informed decision on the impacts of communication losses on their system, as well as evaluating ways to mitigate its impact on the resiliency of the system.

GridLAB-D, Distribution Analysis↗

Novel Quadratic High Gain Boost Converter With Adaptive Soft-Switching Scheme and Reduced Conduction Loss

In this article, an improved soft-switching quadratic boost converter is proposed. Instead of inserting an additional active clamp or auxiliary zero-voltage transition circuit at the switching node, the proposed topology connects the high-voltage switching node to the input diode node by replacing one of the input diodes with a low-rated switch. The proposed topology can attain soft-switching condition for all the switches and input diode turns- off under zero-current switching (ZCS). The operation of input-side switch not only aids zero-voltage switching (ZVS) turn- on for the main switch but also helps in reducing the conduction loss. Also, the input-side switch operates under ZCS turn- on and ZVS turn- off , making it a loss economical solution. An adaptive timing scheme for driving the input switch is proposed, which can ensure soft-switching condition under varying gain and load range. The detailed operational modes, analysis, and design considerations of the proposed topology are presented. A 250 W hardware prototype is built to validate the performance of the proposed converter operating at 100 kHz switching frequency. Results with adaptive soft-switching scheme shows that the converter is modulated to achieve its best efficiency condition under various system conditions. Furthermore, a peak efficiency of 96.1% at 155 W and efficiencies above 95.75% over a wide load range are achieved using all Si devices.

14 SOLAR ENERGY↗

Tomographic Sparse View Selection Using the View Covariance Loss

Standard computed tomography (CT) reconstruction algorithms such as filtered back projection (FBP) and Feldkamp-Davis-Kress (FDK) require many views for producing high-quality reconstructions, which can slow image acquisition and increase cost in non-destructive evaluation (NDE) applications. Over the past 20 years, a variety of methods have been developed for computing high-quality CT reconstructions from sparse views. However, the problem of how to select the best views for CT reconstruction remains open. In this paper, we present a novel view covariance loss (VCL) function that measures the joint information of a set of views by approximating the normalized mean squared error (NMSE) of the reconstruction. We present fast algorithms for computing the VCL along with an algorithm for selecting a subset of views that approximately minimizes its value. Our experiments on simulated and measured data indicate that for a fixed number of views our proposed view covariance loss selection (VCLS) algorithm results in reconstructions with lower NRMSE, fewer artifacts, and greater accuracy than current alternative approaches.

Lin, Jingsong [Purdue University]↗

Loss Minimization With Optimal Power Dispatch in Multi-Frequency HVac Power Systems

Low-frequency high-voltage ac transmission scheme has recently been proposed as an alternative approach for bulk power transmission. This paper proposes a multi-period optimal power flow (OPF) for a multi-frequency HVac transmission system that interconnects both conventional 50/60-Hz and low-frequency grids using back-to-back converters with a centralized control scheme. The OPF objective is to minimize system losses by determining the optimal dispatch for generators, shunt capacitors, and converters. The OPF constraints include the operational constraints of all HVac grid and converter stations. The resulting mixed-integer nonlinear programing problem is solved using a proposed framework based on the predictor-corrector primal-dual interior-point method. The proposed OPF formulation and solution approach are verified using a multi-frequency HVac transmission system that is modified from the IEEE 57-bus system. Here, the results with the optimal dispatch from the proposed method during a simulated day show a significant loss reduction and an improved voltage regulation compared to those when an arbitrary dispatch is chosen.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Fungi rather than bacteria drive early mass loss from fungal necromass regardless of particle size

Microbial necromass is increasingly recognized as an important fast-cycling component of the long-term carbon present in soils. To better understand how fungi and bacteria individually contribute to the decomposition of fungal necromass, three particle sizes (>500, 250–500, and <250 μm) of Hyaloscypha bicolor necromass were incubated in laboratory microcosms inoculated with individual strains of two fungi and two bacteria. Decomposition was assessed after 15 and 28 days via necromass loss, microbial respiration, and changes in necromass pH, water content, and chemistry. To examine how fungal–bacterial interactions impact microbial growth on necromass, single and paired cultures of bacteria and fungi were grown in microplates containing necromass-infused media. Microbial growth was measured after 5 days through quantitative PCR. Regardless of particle size, necromass colonized by fungi had higher mass loss and respiration than both bacteria and uninoculated controls. Fungal colonization increased necromass pH, water content, and altered chemistry, while necromass colonized by bacteria remained mostly unaltered. Bacteria grew significantly more when co-cultured with a fungus, while fungal growth was not significantly affected by bacteria. Collectively, our results suggest that fungi act as key early decomposers of fungal necromass and that bacteria may require the presence of fungi to actively participate in necromass decomposition.

59 BASIC BIOLOGICAL SCIENCES↗

Biotic responses buffer warming-induced soil organic carbon loss in Arctic tundra

Climate warming can result in both abiotic (e.g., permafrost thaw) and biotic (e.g., microbial functional genes) changes in Arctic tundra. Recent research has incorporated dynamic permafrost thaw in Earth system models (ESMs) and indicates that Arctic tundra could be a significant future carbon (C) source due to the enhanced decomposition of thawed deep soil C. However, warming-induced biotic changes may influence biologically related parameters and the consequent projections in ESMs. How model parameters associated with biotic responses will change under warming and to what extent these changes affect projected C budgets have not been carefully examined. Here in this study, we synthesized six data sets over 5 years from a soil warming experiment at the Eight Mile Lake, Alaska, into the Terrestrial ECOsystem (TECO) model with a probabilistic inversion approach. The TECO model used multiple soil layers to track dynamics of thawed soil under different treatments. Our results show that warming increased light use efficiency of vegetation photosynthesis but decreased baseline (i.e., environment-corrected) turnover rates of SOC in both the fast and slow pools in comparison with those under control. Moreover, the parameter changes generally amplified over time, suggesting processes of gradual physiological acclimation and functional gene shifts of both plants and microbes. The TECO model predicted that field warming from 2009 to 2013 resulted in cumulative C losses of 224 or 87 g/m 2 , respectively, without or with changes in those parameters. Thus, warming-induced parameter changes reduced predicted soil C loss by 61%. Our study suggests that it is critical to incorporate biotic changes in ESMs to improve the model performance in predicting C dynamics in permafrost regions.

54 ENVIRONMENTAL SCIENCES↗

Evolutionary innovations through gain and loss of genes in the ectomycorrhizal Boletales

Summary We aimed to identify genomic traits of transitions to ectomycorrhizal ecology within the Boletales by comparing the genomes of 21 symbiotrophic species with their saprotrophic brown‐rot relatives. Gene duplication rate is constant along the backbone of Boletales phylogeny with large loss events in several lineages, while gene family expansion sharply increased in the late Miocene, mostly in the Boletaceae. Ectomycorrhizal Boletales have a reduced set of plant cell‐wall‐degrading enzymes (PCWDEs) compared with their brown‐rot relatives. However, the various lineages retain distinct sets of PCWDEs, suggesting that, over their evolutionary history, symbiotic Boletales have become functionally diverse. A smaller PCWDE repertoire was found in Sclerodermatineae. The gene repertoire of several lignocellulose oxidoreductases (e.g. laccases) is similar in brown‐rot and ectomycorrhizal species, suggesting that symbiotic Boletales are capable of mild lignocellulose decomposition. Transposable element (TE) proliferation contributed to the higher evolutionary rate of genes encoding effector‐like small secreted proteins, proteases, and lipases. On the other hand, we showed that the loss of secreted CAZymes was not related to TE activity but to DNA decay. This study provides novel insights on our understanding of the mechanisms influencing the evolutionary diversification of symbiotic boletes.

Wu, Gang↗

Heat Transfer and Pressure Loss of Additively Manufactured Internal Cooling Channels With Various Shapes

Abstract Additive manufacturing (AM) provides the ability to fabricate highly customized internal cooling passages that are relevant to gas turbine components. This experimental study examines the pressure loss and heat transfer performance of a range of fundamental channel shapes that were produced using direct metal laser sintering. Circular, hexagonal, pentagonal, elliptical, diamond, square, rectangular, trapezoidal, and triangular channel cross sections were investigated. To maintain the same convective surface area between shapes, the wetted perimeters of the channel cross sections were kept constant. Parallel computational fluid dynamic simulations were performed to understand the relationships in cooling performance between several channel shapes. Several characteristic length scales were evaluated to scale the pressure loss and heat transfer measurements. Among the channel shapes investigated, the diamond channel showed the lowest Nusselt number and friction factor. The pentagon exhibited a similar Nusselt number as the circular channel despite having a lower friction factor. There was no difference in scaling the friction factor or Nusselt number results of the different channel shapes between using the square root of cross-sectional area compared to hydraulic diameter as the characteristic length scale

Engineering↗

Are Capacity and Energy Loss Equivalent Metrics for Battery Aging Reporting?

Battery aging in research publications and manufacturer specification sheets for individual cells is commonly reported as capacity (Ah) versus cycle number. However, the key measured quantity in battery-powered devices is energy (Wh), which is derived from integrating capacity with voltage. In this work, we compare the rate of capacity and energy loss across a wide range of Li-ion single-cell cycling studies with different positive electrode chemistries, charge–discharge rates, and temperatures. We find that the relative rate of discharge energy loss varies with cycling conditions. For many cells cycled under moderate conditions, the rate of discharge energy fade is only slightly faster than the rate of discharge capacity fade. However, some cells demonstrated up to a 15% decline in cycle count when 80% energy retention rather than 80% capacity retention was used as the end-of-life metric. These results highlight the importance of reporting cell aging based on energy fade to avoid overestimating battery lifetime in full systems.

batteries↗

Gain and loss mechanisms for neutral species in low pressure fluorocarbon plasmas by infrared spectroscopy

This article examines the chemical reaction pathways of stable neutral species in fluorocarbon plasmas. Octafluorocyclobutane (c-C{sub 4}F{sub 8}) inductively coupled plasma discharges were found to primarily produce stable and metastable products downstream from the discharge, including c-C{sub 4}F{sub 8}, C{sub 2}F{sub 4}, C{sub 2}F{sub 6}, CF{sub 4}, C{sub 3}F{sub 8}, C{sub 4}F{sub 10}, C{sub 3}F{sub 6}, and CF{sub 2}. A novel analysis technique allows the estimation of gain and loss rates for neutral species in the steady state as functions of residence time, pressure, and discharge power. The gain and loss rates show that CF{sub 4}, C{sub 2}F{sub 6}, C{sub 3}F{sub 8}, and C{sub 4}F{sub 10} share related gain mechanisms, speculated to occur at the surface. Further analysis confirms that CF{sub 2} is predominantly produced at the chamber walls through electron impact dissociation of C{sub 2}F{sub 4} and lost through gas-phase addition reactions to form C{sub 2}F{sub 4}. Additionally, time-resolved FTIR spectra provide a second-order rate coefficient of 1.8 Multiplication-Sign 10{sup -14} cm{sup 3}/s for the gas-phase addition of CF{sub 2} to form C{sub 2}F{sub 4}. Finally, C{sub 2}F{sub 4,} which is much more abundant than CF{sub 2} in the discharge, is shown to be dominantly produced through electron impact dissociation of c-C{sub 4}F{sub 8} and lost through either surface or gas-phase addition reactions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Testing a Model of IR Radiative Losses: Preprint

Thermopile pyranometers exhibit IR radiative losses that affect global and diffuse shortwave measurements made with first class thermopile based instruments. Pyrgeometers can be used to measure the sky temperature and are used to calculate the pyranometer?s IR radiative losses.

14 SOLAR ENERGY↗

Sci—Fri PM: Topics — 06: The influence of regional dose sensitivity on salivary loss and recovery in the parotid gland

Purpose: The Quantitative Analyses of Normal Tissue Effects in the Clinic (QUANTEC 2010) survey of radiation dose-volume effects on salivary gland function has called for improved understanding of intragland dose sensitivity and the effectiveness of partial sparing in salivary glands. Regional dose susceptibility of sagittally- and coronally-sub-segmented parotid gland has been studied. Specifically, we examine whether individual consideration of sub-segments leads to improved prediction of xerostomia compared with whole parotid mean dose. Methods: Data from 102 patients treated for head-and-neck cancers at the BC Cancer Agency were used in this study. Whole mouth stimulated saliva was collected before (baseline), three months, and one year after cessation of radiotherapy. Organ volumes were contoured using treatment planning CT images and sub-segmented into regional portions. Both non-parametric (local regression) and parametric (mean dose exponential fitting) methods were employed. A bootstrap technique was used for reliability estimation and cross-comparison. Results: Salivary loss is described well using non-parametric and mean dose models. Parametric fits suggest a significant distinction in dose response between medial-lateral and anterior-posterior aspects of the parotid (p<0.01). Least-squares and least-median squares estimates differ significantly (p<0.00001), indicating fits may be skewed by noise or outliers. Salivary recovery exhibits a weakly arched dose response: the highest recovery is seen at intermediate doses. Conclusions: Salivary function loss is strongly dose dependent. In contrast no useful dose dependence was observed for function recovery. Regional dose dependence was observed, but may have resulted from a bias in dose distributions.

60 APPLIED LIFE SCIENCES↗

Dependence of the energy lifetime on the type of anomalous losses in stellarators

A relatively simple model of transport process in stellarators that was proposed earlier by the author on the basis of neoclassical theory makes it possible to determine the density and temperature profiles of the plasma components, the ambipolar electric field profile, and the particle and energy lifetimes from the given device parameters and given particle and energy sources with allowance for anomalous losses. The results of numerical simulations carried out with this model for the L-2M, ATF, CHS, and LHD stellarators over broad ranges of plasma densities and absorbed powers showed that the plasma energy lifetimes in these devices coincide to within factors on the order of two with those found from empirical scalings. A specific model of anomalous losses was chosen for calculations. Results are presented from simulations with a more general form of the anomalous thermal conductivity. Namely, the thermal conductivity is chosen to be K{sub j}{sup (a)} {approx} N{sup {alpha}T}{sub j}{sup {beta}B}{sub 0}{sup -{gamma}}, where N(r) is the plasma density and T{sub j}(r) is the temperature of the jth plasma component (j = e, i). The parameters {alpha}, {beta}, and {gamma} are set equal to {alpha} = 1, {beta} = 2, and {gamma} = 1; {alpha} = 0.5, {beta} = 2.5, and {gamma} = 1; {alpha} = 1.5, {beta} = 2, and {gamma} = 2; {alpha} = 1, {beta} = 2.5, and {gamma} = 2; and {alpha} = 1.5, {beta} = 2.5, and {gamma} = 2. The simulations have been done for the L-2M and LHD stellarators. It is found that, in all the five models, the calculated energy lifetimes {tau}{sub c} are essentially independent of the functional form of the anomalous thermal conductivity and coincide to within a factor on the order of two with those following from the LHD scaling.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Suppression of longitudinal losses in a gas-dynamic trap by using an ambipolar mirror

The efficiency of utilizing ambipolar mirrors for suppression of longitudinal losses of particles and energy in a gas-dynamic trap (GDT) was investigated. An additional relatively small axisymmetric mirror cell was installed in one of the facility ends. Hydrogen or deuterium atomic beams with an energy of 22 keV and equivalent current density of up to 1 A/cm{sup 2} were injected into the additional cell at an angle of 90{sup o} to the facility axis. Trapping of the beams with a total power of 800 kW by the plasma in the additional cell leads to the formation of a hot ion population with an anisotropic velocity distribution, a mean energy of 13 keV, and a density of up to 4.5 x 10{sup 13} cm{sup -3}. It is shown that the confinement of hot ions in the additional cell is determined by classical processes, such as charge exchange on the beam atoms and collisional deceleration by electrons, in spite of the onset of Alfven ion-cyclotron instability at fast ion densities higher than 2.5 x 10{sup 13} cm{sup -3}. The effect of ambipolar confinement manifests itself in that, at hot ion densities higher than 3 x 10{sup 13} cm{sup -3}, the flux density of ions escaping from the trap in the mode with beam injection decreases fivefold as compared to that without injection. In this case, the density of the Maxwellian plasma component in the central cell is about 2.5 x 10{sup 13} cm{sup -3}. The efficiency of suppression of longitudinal particle losses by the ambipolar mirror substantially exceeds estimates obtained for both collisional (gas-dynamic) and collisionless (adiabatic) confinement modes. Qualitatively, this is because, in the GDT experiments, the mode of warm plasma confinement is transitional between the gas-dynamic and adiabatic modes and the use of an ambipolar mirror facilitates a transition from the lossy gas-dynamic mode into a nearly adiabatic one.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Determination of energy release zones arising due to current losses in the convolution region of the magnetically insulated transmission lines of the ANGARA-5-1 facility

Among the factors limiting electromagnetic pulse transmission to the load in high-power electro-physical facilities, current losses in magnetically insulated transmission lines (MITLs) are of significant importance. One of such facilities is ANGARA-5-1—a multimodule facility with an output electric power of up to 6 TW. A fairly complicated configuration of the magnetic field in the convolution region of several MITLs makes it difficult to fix the places of current losses there. In this work, these places were determined by detecting the positions of IR sources in the convolution region of the MITLs of the ANGARA-5-1 facility.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Surface Plasmon Resonances of an Axially Magnetized Plasma Column in the Presence of Collisional Loss

Surface plasmon resonances arising in the course of scattering of an H-polarized plane electromagnetic wave by an axially magnetized plasma column are analyzed. Main attention is paid to the behavior of these resonances in the presence of collisional loss in the magnetoplasma filling the scatterer. The frequencies, Q factors, and amplitude coefficients of the electromagnetic field of multipole surface plasmon resonances of different orders are found, and conditions under which the collisional loss in the plasma completely suppresses a given resonance are determined.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Electroluminescence and absorption spectra of low-optical-loss semiconductor lasers based on InGaAs/AlGaAs/GaAs QW heterostructures

Spontaneous emission, optical loss, and gain spectra of a laser heterostructure with a quantum-well InGaAs active region have been studied at various optical and electrical pumping levels. It is shown that carrier accumulation in the active region under open-circuit conditions for the photocurrent leads to disappearance of the long-wavelength edge peak in the absorption spectrum. It is found that flowing photocurrent precludes accumulation of photogenerated carriers, with the result that the absorption spectrum retains its shape, irrespective of the optical pumping level. It is shown that many-particle effects of carrier interaction lead to a temperature-unrelated narrowing of the band gap in the InGaAs quantum-well active region by up to 30 meV and to tailing of the long-wavelength edge of the gain spectrum. As a result, a spectral range can be found for mesa-stripe laser diodes in which the gain in the region under the stripe contact is positive and the loss in passive regions is close to zero.

36 MATERIALS SCIENCE↗