Search NASA⌕ Search

SEARCH · Search NASA

Results for “MAGNETIC RESONANCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,765 records · Page 98

Initial Aging Studies of Unfilled VCE

This report presents initial data on the effects of temperature, oxygen, and radiation on the chemical and structural properties of newly formulated, unfilled VCE. This initial effort focused on a pristine sample, and a replicate sample irradiated in air at a dose of 25MR. Thermal degradation was investigated by performing Thermogravimetric Analysis (TGA), and radiation-induced degradation was investigated using Differential Scanning Calorimetry (DSC), X-ray Diffraction (XRD), Solid Phase MicroExtraction--Gas Chromatography/Mass Spectrometry (SPME-GC/MS), as well as various Nuclear Magnetic Resonance (NMR) techniques including: {sup 13}C, {sup 13}C {sup 1}H cross polarization (CP), and {sup 1}H magic angle spinning (MAS) NMR.

36 MATERIALS SCIENCE↗

Lumbar spine disc heights and curvature: upright posture vs. supine compression harness

INTRODUCTION: Spinal lengthening in microgravity is thought to cause back pain in astronauts. A spinal compression harness can compress the spine to eliminate lengthening but the loading condition with harness is different than physiologic conditions. Our purpose was to compare the effect of spine compression with a harness in supine position on disk height and spinal curvature in the lumbar spine to that of upright position as measured using a vertically open magnetic resonance imaging system. METHODS: Fifteen healthy subjects volunteered. On day 1, each subject lay supine for an hour and a baseline scan of the lumbar spine was performed. After applying a load of fifty percent of body weight with the harness for thirty minutes, the lumbar spine was scanned again. On day 2, after a baseline scan, a follow up scan was performed after kneeling for thirty minutes within the gap between two vertically oriented magnetic coils. Anterior and posterior disk heights, posterior disk bulging, and spinal curvature were measured from the baseline and follow up scans. RESULTS: Anterior disk heights increased and posterior disk heights decreased compared with baseline scans both after spinal compression with harness and upright posture. The spinal curvature increased by both loading conditions of the spine. DISCUSSION: The spinal compression with specially designed harness has the same effect as the physiologic loading of the spine in the kneeling upright position. The harness shows some promise as a tool to increase the diagnostic capabilities of a conventional MR system.

Non-NASA Center↗

Characterization of Highly Nonlinear and Anisotropic Vascular Tissues from Experimental Inflation Data: a Validation Study Towards the Use of Clinical Data for In-vivo Modeling and Analysis

A new ¯nite element (FE) modeling approach is proposed to model blood vessel by using data from blood vessel during in°ation instead of using data from biaxial test to estimate the tissue property. A particular constitutive equation is used to model the tissue property as a dispersed transverse isotropic hyperelastic material under both single-layer and multi-layer assumption for comparison. In order to compensate the drawback of using this type of data that does not provide su±cient information to estimate the tissue property in axial direction, the axial/circumferential elastic moduli ratio is being constrained in a typical range. The semi-global inverse method is applied with the pressure-diameter test data from porcine thoracic aorta to esti- mate the optimal tissue property. The simulated data of all cases is then compared with the biaxial test data. It is found that the single-layer model without the con- straint ¯ts well with the pressure-diameter test data but not with the biaxial test data at the axial direction, so it is suitable only for pressure-diameter analysis. The multi-layer model with the constraint ¯ts well with the pressure-diameter data and also the biaxial test data, so it is suitable to estimate the tissue property and for stress-strain analysis. The constitutive equation and the semi-global inverse method are found e±cient in this study. We believe that this new approach that uses this type of data, such as magnetic resonance imaging (MRI) data that could be ob- tained non-invasive in vivo, is time-e±cient and would be bene¯cial for pre-surgical analysis.

59 BASIC BIOLOGICAL SCIENCES↗

A compact, multichannel, and low noise arbitrary waveform generator

A new type of high functionality, fast, compact, and easy programmable arbitrary waveform generator for low noise physical measurements is presented. The generator provides 7 fast differential waveform channels with a maximum bandwidth up to 200 MHz frequency. There are 6 fast pulse generators on the generator board with 78 ps time resolution in both duration and delay, 3 of them with amplitude control. The arbitrary waveform generator is additionally equipped with two auxiliary slow 16 bit analog-to-digital converters and four 16 bit digital-to-analog converters for low frequency applications. Electromagnetic shields are introduced to the power supply, digital, and analog compartments and with a proper filter design perform more than 110 dB digital noise isolation to the output signals. All the output channels of the board have 50 Ω SubMiniature version A termination. The generator board is suitable for use as a part of a high sensitive physical equipment, e.g., fast read out and manipulation of nuclear magnetic resonance or superconducting quantum systems and any other application, which requires electromagnetic interference free fast pulse and arbitrary waveform generation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Hydrogenation of liquid natural rubber via diimide reduction in hydrazine hydrate/hydrogen peroxide system

Liquid natural rubber (LNR) with molecular weight of lower than 10{sup 5} and shorter polymeric chain than natural rubber was prepared. LNR was then hydrogenated via diimide reduction by oxidation of hydrazine hydrate with hydrogen peroxide. The unsaturated units of the rubber were converted into saturated hydrocarbon to strengthen the backbone of the polymer so it was able to resist thermal degradation. The results indicated that hydrogenation degree of the product (HLNR) could be extended to 91.2% conversion under appropriate conditions. The hydrogenated LNR (HLNR) was characterized using Fourier-Transform Infrared (FTIR) and Nuclear Magnetic Resonance (NMR) spectroscopy. The physical characteristics of HLNR were analyzed with Termogravimetric Analysis (TGA)

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

COMBINING NEUTRAL AND ACIDIC EXTRACTANTS FOR RECOVERING TRANSURANIC ELEMENTS FROM NUCLEAR FUEL

We have been investigating a solvent extraction system that combines a neutral extractant--octyl(phenyl)-N,N-diisobutyl-carbamoylmethylphosphine oxide (CMPO)--with an acidic extractant--bis(2-ethylhexyl)phosphoric acid (HDEHP)--to form a single process solvent for separating Am and Cm from the other components of irradiated nuclear fuel. It was originally hypothesized that the extraction chemistry of CMPO would dominate under conditions of high acidity (> 1 M HNO3), resulting in co-extraction of the transuranic and lanthanide elements into the organic phase. Contacting the loaded solvent with a solution of diethylenetriaminepentaacetate (DTPA) buffered with lactic or citric acid at pH {approx}3 to 4 would result in a condition in which the HDEHP chemistry dominates. Although the data somewhat support this hypothesis, it is clear that there are interactions between the two extractants such that they do not act independently in the extraction and stripping regimes. We report here studies directed at determining the nature and extent of interaction between CMPO and HDEHP, the synergistic behavior of CMPO and HDEHP in the extraction of americium and neodymium, and progress towards determining the thermodynamics of this extraction system. Neodymium and americium behave similarly in the combined solvent system, with a significant synergy between CMPO and HDEHP in the extraction of both of these trivalent elements from lactate-buffered DTPA solutions. In contrast, a much weaker synergistic behaviour is observed for europium. Thus, investigations into the fundamental chemistry involved in this system have focused on the neodymium extraction. The extraction of neodymium has been systematically investigated, individually varying the HDEHP concentration, the CMPO concentration, or the aqueous phase composition. Thermodynamic modeling of the neodymium extraction system has been initiated. Interactions between CMPO and HDEHP in the organic phase must be taken into account in the thermodynamic modeling; such interactions have been quantified by nuclear magnetic resonance measurements.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Local structures of polar wurtzites Zn1-xMgxO studied by raman and 67Zn/25Mg NMR spectroscopies and by total neutron scattering

Research in the area of polar semiconductor heterostructures has been growing rapidly, driven in large part by interest in two-dimensional electron gas (2DEG) systems. 2DEGs are known to form at heterojunction interfaces that bear polarization gradients. They can display extremely high electron mobilities, especially at low temperatures, owing to spatial confinement of carrier motions. Recent reports of 2DEG behaviors in Ga{sub 1-x}Al{sub x}N/GaN and Zn{sub 1-x}Mg{sub x}O/ZnO heterostructures have great significance for the development of quantum Hall devices and novel high-electron-mobility transistors (HEMTs). 2DEG structures are usually designed by interfacing a polar semiconductor with its less or more polar alloys in an epitaxial manner. Since the quality of the 2DEG depends critically on interface perfection, as well as the polarization gradient at the heterojunction, understanding compositional and structural details of the parent and alloy semiconductors is an important component in 2DEG design and fabrication. Zn{sub 1-x}Mg{sub x}O/ZnO is one of the most promising heterostructure types for studies of 2DEGs, due to the large polarization of ZnO, the relatively small lattice mismatch, and the large conduction band offsets in the Zn{sub 1-x}Mg{sub x}O/ZnO heterointerface. Although 2DEG formation in Zn{sub 1-x}Mg{sub x}O/ZnO heterostructures have been researched for some time, a clear understanding of the alloy structure of Zn{sub 1-x}Mg{sub x}O is currently lacking. Here, we conduct a detailed and more precise study of the local structure of Zn{sub 1-x}Mg{sub x}O alloys using Raman and solid-state nuclear magnetic resonance (NMR), in conjunction with neutron diffraction techniques.

36 MATERIALS SCIENCE↗

Parallel high-frequency magnetic sensing with an array of flux transformers and multi-channel optically pumped magnetometer for hand MRI application

Here, we investigate an approach for parallel high-frequency magnetic sensing based on a multi-channel radio frequency (RF) optically pumped magnetometer (OPM) coupled to multiple flux transformers (FTs) with a focus on hand magnetic resonance imaging (MRI) application at ultra-low field (ULF). Multiple RF OPM sensing channels are realized by using a single large-area alkali-metal vapor cell and two laser beams for pumping and probing, shared for all the channels. This design leads to significant cost reduction when multi-channel sensing is desirable, as in the case of ULF MRI. The FT, composed of two connected coils, serves as a transmitter of a target magnetic field to the OPM, while decoupling the OPM from untargeted magnetic fields in the sensing area that can limit the OPM performance. For hand MRI application, theoretical and numerical analysis is performed to determine an optimal geometry for the FT array that could improve signal-to-noise ratio (SNR) and sufficiently reduce crosstalk between FTs. We estimate that the optimized multi-channel FT-OPM sensor can achieve a magnetic field sensitivity of the order of 1 fT / Hz 1 / 2 above 100 kHz, which would be sufficient for 1 mm resolution MRI. In general, the multi-channel capability enables simultaneous magnetic measurements, thus reducing the sensing time and improving the SNR, and we anticipate many applications of the multi-channel FT-OPM sensor beyond the targeted here hand MRI: anatomical parallel ULF MRI of the human brain and other parts of the body, airport security screening, magnetic material imaging, and many others.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Calorimetric measurement of nuclear spin-lattice relaxation rate in metals

The quasiparticle density of states in correlated and quantum-critical metals directly probes the effect of electronic correlations on the Fermi surface. Measurements of the nuclear spin-lattice relaxation rate provide one such experimental probe of quasiparticle mass through the electronic density of states. By far the most common way of accessing the spin-lattice relaxation rate is via nuclear magnetic resonance and nuclear quadrupole resonance experiments, which require resonant excitation of nuclear spin transitions. Here we report nonresonant access to spin-lattice relaxation dynamics in AC-calorimetric measurements. The nuclear spin-lattice relaxation rate is inferred in our measurements from its effect on the frequency dispersion of the thermal response of the calorimeter-sample assembly. Further, we use fast, lithographically defined nanocalorimeters to access the nuclear spin-lattice relaxation times in metallic indium from 0.3 to 7 K and in magnetic fields up to 35 T.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Synthesis and characterization of carboxymethyl cellulose from office waste paper: A greener approach towards waste management

Highlights: • Carboxymethyl cellulose (CMC) was successfully prepared from waste paper. • CMC had maximum degree of substitution (DS) 1.07. • Rheological studies of CMC (DS, 1.07) showed non-Newtonian pseudoplastic behavior. • Characterization of CMC was done by FT-IR and NMR techniques. • Morphology of prepared CMC was studied by SEM. - Abstract: In the present study, functionalization of mixed office waste (MOW) paper has been carried out to synthesize carboxymethyl cellulose, a most widely used product for various applications. MOW was pulped and deinked prior to carboxymethylation. The deinked pulp yield was 80.62 ± 2.0% with 72.30 ± 1.50% deinkability factor. The deinked pulp was converted to CMC by alkalization followed by etherification using NaOH and ClCH{sub 2}COONa respectively, in an alcoholic medium. Maximum degree of substitution (DS) (1.07) of prepared CMC was achieved at 50 °C with 0.094 M and 0.108 M concentrations of NaOH and ClCH{sub 2}COONa respectively for 3 h reaction time. The rheological characteristics of 1–3% aqueous solution of optimized CMC product showed the non-Newtonian pseudoplastic behavior. Fourier transform infra red (FTIR), nuclear magnetic resonance (NMR) and scanning electron microscope (SEM) study were used to characterize the CMC product.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Nanotesla Magnetometry with the Silicon Vacancy in Silicon Carbide

Silicon carbide is a promising host material for spin-defect-based quantum sensors owing to its commercial availability and established techniques for electrical and optical microfabricated device integration. The negatively charged silicon vacancy is one of the leading spin defects studied in silicon carbide owing to its near-telecom photoemission, high spin number, and nearly temperature-independent ground-state zero-field splitting. We report the realization of nanotesla shot-noise-limited ensemble magnetometry based on optically detected magnetic resonance with the silicon vacancy in 4H silicon carbide. By coarsely optimizing the anneal parameters and minimizing power broadening, we achieve a sensitivity of 50 nT/√Hz and a theoretical shot-noise-limited sensitivity of 3.5 nT/√Hz. This is accomplished without utilizing complex photonic engineering, control protocols, or applying excitation powers greater than a watt. This work demonstrates that the silicon vacancy in silicon carbide provides a low-cost and simple approach to quantum sensing of magnetic fields.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Effect of longitudinal magnetic fields on a simulated in-line 6 MV linac

Purpose: Linac-magnetic resonance (MR) systems have been proposed in order to achieve real-time image guided radiotherapy. The design of a new linac-MR system with the in-line 6 MV linac generating x-rays along the symmetry axis of an open MR imager is outlined. This new design allows for a greater MR field strength to achieve better quality images while reducing hot and cold spots in treatment planning. An investigation of linac's performance in the longitudinal fringe magnetic fields of the MR imager is given. Methods: The open MR imager fringe magnetic field was modeled using the analytic solution of the magnetic field generated from current carrying loops. The derived solution was matched to the magnetic fringe field isolines provided for a 0.5 T open MR imager through Monte Carlo optimization. The optimized field solution was then added to the previously validated 6 MV linac simulation to quantify linac's performance in the fringe magnetic field of a 0.5 T MR imager. To further the investigation, linac's performance in large fringe fields expected from other imagers was investigated through the addition of homogeneous longitudinal fields. Results: The Monte Carlo optimization of the analytic current loop solution provided good agreement with the magnetic fringe field isolines supplied by the manufacturer. The range of magnetic fields the linac is expected to experience when coupled to the 0.5 T MR imager was determined to be from 0.0022 to 0.011 T (as calculated at the electron gun cathode). The effect of the longitudinal magnetic field on the electron beam was observed to be only in the electron gun. The longitudinal field changed the electron gun optics, affecting beam characteristics, such as a slight increase in the injection current and beam diameter, and an increasingly nonlaminar transverse phase space. Although the target phase space showed little change in its energy spectrum from the altered injection phase space, a reduction in the target current and spatial distribution peak intensity was observed. Despite these changes, the target phase space had little effect on the depth dose curves or dose profiles calculated for a 40x40 cm{sup 2} field at 1.5 cm depth. At longitudinal fields larger than 0.012 T, a drastic reduction in the injection current from the electron gun was observed due to a large fraction of electrons striking the anode. This further reduced the target current, which reached a minimum of 28{+-}2 mA at 0.06 T. A slow increase in the injection and target currents was observed at fields larger than 0.06 T due to greater beam collimation in the anode beam tube. Conclusions: In an effort to achieve higher quality images and a reduction in hot and cold spots in the treatment plan, a parallel configuration linac-MR system is presented. The longitudinal magnetic fields of the MR imager caused large beam losses within the electron gun. These losses may be eliminated through a redesign of the electron gun optics incorporating a longitudinal magnetic field, or through magnetic shielding, which has already been proven successful for the transverse configuration.

61 RADIATION PROTECTION AND DOSIMETRY↗

Polarized Solid Targets - Present and Future

The development, in the early 1960s, of the dynamic nuclear polarization scheme in solid diamagnetic materials, doped with paramagnetic radicals, led to the use of solid polarized H and D targets in numerous nuclear and particle physics experiments. Since then steady progress has been made in all contributing sub-systems so that proton polarization values around 90% and deuteron polarization values between 40% and 80% have been achieved in various set-ups. These polarization values have been measured with a relative accuracy of {+-}5% or better using nuclear magnetic resonance techniques. Many experiments with reasonably high luminosities have taken advantage of these developments and many more are being planned, especially with electromagnetic probes. Latest developments open up the possibility to use DNP hyperpolarized substances for medical applications.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Equatorial Electronic Structure in the Uranyl Ion: Cs 2 UO 2 Cl 4 and Cs 2 UO 2 Br 4

Electric field gradient (EFG) tensors in the equatorial plane of the linear UO 2 2+ ion have been measured by nuclear magnetic resonance (NMR) and nuclear quadrupole resonance (NQR) experiments and computed by relativistic Kohn–Sham methods with and without environment embedding for Cs 2 UO 2 Cl 4 and Cs 2 UO 2 Br 4 . This approach expands the possibilities for probing the electronic structure in uranyl complexes beyond the strongly covalent U–O bonds. The combined analyses find that one of the two largest principal EFG tensor components at the halogen sites points along the U–X bond (X = Cl, Br), and the second is parallel to the UO 2 2+ ion; in Cs 2 UO 2 Cl 4 , the components are nearly equal in magnitude, whereas in Cs 2 UO 2 Br 4 , due to short-range bromide–cesium interactions, the equatorial component is dominant for one pair of Br sites and the axial component is larger for the second pair. Additionally, the directions and relative magnitudes of the field gradient principal axes are found to be sensitive to the σ and π electron donation by the ligands and the model of the environment. Chlorine-35 NQR spectra of 235 U-depleted and 235 U-enriched Cs 2 UO 2 Cl 4 exhibited no uranium-isotope-dependent shift, but the resonance of the depleted sample displayed a 58% broader line width.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Effect of low-damage inductively coupled plasma on shallow nitrogen-vacancy centers in diamond

Near-surface nitrogen-vacancy (NV) centers in diamond have been successfully employed as atomic-sized magnetic field sensors for external spins over the last years. A key challenge is still to develop a method to bring NV centers at nanometer proximity to the diamond surface while preserving their optical and spin properties. To that aim we present a method of controlled diamond etching with nanometric precision using an oxygen inductively coupled plasma process. Importantly, no traces of plasma-induced damages to the etched surface could be detected by X-ray photoelectron spectroscopy and confocal photoluminescence microscopy techniques. In addition, by profiling the depth of NV centers created by 5.0 keV of nitrogen implantation energy, no plasma-induced quenching in their fluorescence could be observed. Moreover, the developed etching process allowed even the channeling tail in their depth distribution to be resolved. Furthermore, treating a {sup 12}C isotopically purified diamond revealed a threefold increase in T{sub 2} times for NV centers with <4 nm of depth (measured by nuclear magnetic resonance signal from protons at the diamond surface) in comparison to the initial oxygen-terminated surface.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Characterizing Radiation-Aged Polysiloxane-Silica Composites: Identifying Changes in Network Topology via 1H NMR

Characterizing and quantifying changes in elastomeric materials upon exposure to harsh environments is important in the estimation of device lifetimes. Nuclear magnetic resonance (NMR) spectroscopy has been used effectively in the analysis of such materials and has proved to be both sensitive to micro- and macroscopic changes associated with material 'aging'. Traditional analyses, however, rely on empirical formulae containing a large number of (often arbitrary) independent variables. This ambiguity can be circumvented largely by developing models of NMR observables that are based on basic polymer physics. We compare two such models, one previously published and one derived herein, along with empirical expressions that describe the proton transverse magnetization decay associated with complex polymer networks. One particular extracted parameter, the proton-proton residual dipolar coupling (RDC), can be directly related to network topology, and a comparison of the extracted RDCs reveals high consistency among the models. An expression derived from the properties of a static Gaussian chain can minimize the number of parameters necessarily to describe the solid-like, networked proton population to a single independent parameter, the average residual dipolar coupling, D{sub avg}.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

In-situ pore size investigations of loaded porous concrete with non-destructive methods

Subject of this investigation is the in-situ evolution of pore volume and pore size distribution in Ytong (a porous concrete material) under increasing pressure with two different non-destructive analytical methods: Nuclear Magnetic Resonance (NMR) and X-ray Computed Tomography (CT). For both methods special strain devices to apply external pressure were constructed. The results from the two techniques yield complementary information on the pore size distribution and allows covering different pore size regions.

36 MATERIALS SCIENCE↗

Effects of ionic liquids on cation dynamics in amorphous polyethylene oxide electrolytes

We perform extensive molecular dynamics simulations of a poly(ethylene oxide)-based polymer electrolyte material containing lithium bis(trifluoromethanesulfonyl)imide salt for a wide temperature regime above and below the experimental crystallization temperature with and without N-methyl-N-propylpyrrolidinium bis(trifluoromethanesulfonyl)imide ionic liquid (IL). The impact of the IL-concentration on the cation dynamics is studied. The increase of the cation mobility upon addition of IL is significant but temperature-independent. This can be related to distinct variations of the underlying transport properties as expressed within the previously introduced transport model of polymer electrolytes. Even for the largest IL concentration the transport model perfectly predicts the non-trivial time-dependence of the cationic mean square displacement for all temperatures. Finally, we compare our numerical and theoretical findings with the results of recent nuclear magnetic resonance experiments. In this way we can exclusively relate the strong experimentally observed dependence of the low-temperature Li-diffusivity on the IL concentration to the impact of IL on crystallization.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗