Search NASA⌕ Search

SEARCH · Search NASA

Results for “Method development”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,765 records · Page 98

THE M31 NEAR-INFRARED PERIOD-LUMINOSITY RELATION AND ITS NON-LINEARITY FOR δ Cep VARIABLES WITH 0.5 ≤ log (P) ≤ 1.7

We present the largest M31 near-infrared (F110W (close to J band), F160W (H band)) Cepheid sample so far. The sample consists of 371 Cepheids with photometry obtained from the Hubble Space Telescope PHAT program. The sample of 319 fundamental mode Cepheids, 16 first overtone Cepheids, and 36 type II Cepheids was identified using the median absolute deviation outlier rejection method we develop here. This method does not rely on priors and allows us to obtain this clean Cepheid sample without rejecting a large fraction of Cepheids. The obtained period-luminosity relations (PLRs) have a very small dispersion, i.e., 0.155 mag in F160W, despite using random phased observations. This remarkably small dispersion allows us to determine that the PLRs are significantly better described by a broken slope at 10 days than a linear slope. The use of our sample as an anchor to determine the Hubble constant gives a 3.2% larger Hubble constant compared to the Riess et al. sample.

79 ASTRONOMY AND ASTROPHYSICS↗

DEVELOPMENT OF A METHOD FOR THE OBSERVATION OF LIGHTNING IN PROTOPLANETARY DISKS USING ION LINES

In this paper, we propose observational methods for detecting lightning in protoplanetary disks. We do so by calculating the critical electric field strength in the lightning matrix gas (LMG), the parts of the disk where the electric field is strong enough to cause lightning. That electric field accelerates multiple positive ion species to characteristic terminal velocities. In this paper, we present three distinct discharge models with corresponding critical electric fields. We simulate the position–velocity diagrams and the integrated emission maps for the models. We calculate the measure-of-sensitivity values for detection of the models and for distinguishing between the models. At the distance of TW Hya (54 pc), LMG that occupies 2π in azimuth and has 25 AU < r < 50 AU is detectable at 1200σ to 4000σ. The lower limits of the radii of 5σ-detectable LMG clumps are between 1.6 AU and 5.3 AU, depending on the models.

79 ASTRONOMY AND ASTROPHYSICS↗

Development of a Method for Shape Optimization for a Gas Turbine Fuel Injector Design Using Metal-Additive Manufacturing

Adjoint shape optimization has enabled physics-based optimal designs for aerodynamic surfaces. Additive manufacturing (AM) makes it possible to manufacture complex shapes. However, there has been a gap between optimal and manufacturable surfaces due to the inherent limitations of commercial computational fluid dynamics (CFD) codes to implement geometric constraints during adjoint computation. In such cases, the design sensitivities are exported and used to perform constrained shape modifications using parametric information stored in computer aided design (CAD) files to satisfy manufacturability constraints. However, modifying the design using adjoint methods in CFD solvers and performing constrained shape modification in CAD can lead to inconsistencies due to different shape parameterization schemes. This paper describes a method to enable the simultaneous optimization of the fluid domain and impose AM manufacturability constraints, resolving one of the key issues of geometry definition for isogeometric analysis. Similar to a grid convergence study, the proposed method verifies the consistencies between shape parameterization techniques present within commercial CAD and CFD software during mesh movement as a part of the adjoint shape optimization routine. By identifying the appropriate parameters essential to a shape optimization study, the error metric between the different parameterization techniques converges to demonstrate sufficient consistencies for justifiable exchange of data between CAD and CFD. For the identified shape optimization parameters, the error metric to measure the deviation between the two parameterization schemes lies within the AM laser-powder bed fusion (L-PBF) process tolerance. Additionally, comparison for subsequent objective function calculations between iterations of the optimization loop showed acceptable differences within 1% variation between the modified geometries obtained using the two parameterization schemes. This method provides justification for the use of multiphysics guided adjoint design sensitivities computed in CFD software to perform shape modifications in CAD to incorporate AM manufacturability constraints during the shape optimization loop such that optimal designs are also additively manufacturable.

33 ADVANCED PROPULSION SYSTEMS↗

WE-F-16A-05: Use of 3D-Printers to Create a Tissue Equivalent 3D-Bolus for External Beam Therapy

Purpose: The purpose of this project is to demonstrate that a non-expensive 3D-printer can be used to manufacture a 3D-bolus for external beam therapy. The printed bolus then can be modeled in our treatment planning system to ensure accurate dose delivery to the patient. Methods: We developed a simple method to manufacture a patient-specific custom 3Dbolus. The bolus is designed using Eclipse Treatment Planning System, contoured onto the patients CT images. The bolus file is exported from Eclipse to 3D-printer software, and then printed using a 3D printer. Various tests were completed to determine the properties of the printing material. Percent depth dose curves in this material were measured with electron and photon beams for comparison to other materials. In order to test the validity of the 3D printed bolus for treatment planning, a custom bolus was printed and tested on the Rando phantom using film for a dose plane comparison. We compared the dose plane measured on the film to the same dose plane exported from our treatment planning system using Film QA software. The gamma-dose distribution tool was used in our film analysis. Results: We compared point measurements throughout the dose plane and were able to achieve greater than 95% passing rate at 3% dose difference and 3 mm distance to agreement, which is our departments acceptable gamma pixel parameters. Conclusion: The printed 3D bolus has proven to be accurately modeled in our treatment planning system, it is more conformal to the patient surface and more durable than other bolus currently used (wax, superflab etc.). It is also more convenient and less costly than comparable bolus from milling machine companies.

60 APPLIED LIFE SCIENCES↗

WE-G-BRF-09: Force- and Image-Adaptive Strategies for Robotised Placement of 4D Ultrasound Probes

Purpose: To allow continuous acquisition of high quality 4D ultrasound images for non-invasive live tracking of tumours for IGRT, image- and force-adaptive strategies for robotised placement of 4D ultrasound probes are developed and evaluated. Methods: The developed robotised ultrasound system is based on a 6-axes industrial robot (adept Viper s850) carrying a 4D ultrasound transducer with a mounted force-torque sensor. The force-adaptive placement strategies include probe position control using artificial potential fields and contact pressure regulation by a PD controller strategy. The basis for live target tracking is a continuous minimum contact pressure to ensure good image quality and high patient comfort. This contact pressure can be significantly disturbed by respiratory movements and has to be compensated. All measurements were performed on human subjects under realistic conditions. When performing cardiac ultrasound, rib- and lung shadows are a common source of interference and can disrupt the tracking. To ensure continuous tracking, these artefacts had to be detected to automatically realign the probe. The detection is realised by multiple algorithms based on entropy calculations as well as a determination of the image quality. Results: Through active contact pressure regulation it was possible to reduce the variance of the contact pressure by 89.79% despite respiratory motion of the chest. The results regarding the image processing clearly demonstrate the feasibility to detect image artefacts like rib shadows in real-time. Conclusion: In all cases, it was possible to stabilise the image quality by active contact pressure control and automatically detected image artefacts. This fact enables the possibility to compensate for such interferences by realigning the probe and thus continuously optimising the ultrasound images. This is a huge step towards fully automated transducer positioning and opens the possibility for stable target tracking in ultrasoundguided radiation therapy requiring contact pressure of 5–10 N. This work was supported by the Graduate School for Computing in Medicine and Life Sciences funded by Germany's Excellence Initiative [DFG GSC 235/1].

60 APPLIED LIFE SCIENCES↗

3D/3D registration of coronary CTA and biplane XA reconstructions for improved image guidance

Purpose: The authors aim to improve image guidance during percutaneous coronary interventions of chronic total occlusions (CTO) by providing information obtained from computed tomography angiography (CTA) to the cardiac interventionist. To this end, the authors investigate a method to register a 3D CTA model to biplane reconstructions. Methods: The authors developed a method for registering preoperative coronary CTA with intraoperative biplane x-ray angiography (XA) images via 3D models of the coronary arteries. The models are extracted from the CTA and biplane XA images, and are temporally aligned based on CTA reconstruction phase and XA ECG signals. Rigid spatial alignment is achieved with a robust probabilistic point set registration approach using Gaussian mixture models (GMMs). This approach is extended by including orientation in the Gaussian mixtures and by weighting bifurcation points. The method is evaluated on retrospectively acquired coronary CTA datasets of 23 CTO patients for which biplane XA images are available. Results: The Gaussian mixture model approach achieved a median registration accuracy of 1.7 mm. The extended GMM approach including orientation was not significantly different (P > 0.1) but did improve robustness with regards to the initialization of the 3D models. Conclusions: The authors demonstrated that the GMM approach can effectively be applied to register CTA to biplane XA images for the purpose of improving image guidance in percutaneous coronary interventions.

60 APPLIED LIFE SCIENCES↗

SU-F-T-547: Off-Isocenter Winston-Lutz Test for Stereotactic Radiosurgery/stereotactic Body Radiotherapy

Purpose: To perform a quantitative study to verify that the mechanical field center coincides with the radiation field center when both are off from the isocenter during the single-isocenter technique in linear accelerator-based SRS/SBRT procedure to treat multiple lesions. Methods: We developed an innovative method to measure this accuracy, called the off-isocenter Winston-Lutz test, and here we provide a practical clinical guideline to implement this technique. We used ImagePro V.6 to analyze images of a Winston-Lutz phantom obtained using a Varian 21EX linear accelerator with an electronic portal imaging device, set up as for single-isocenter SRS/SBRT for multiple lesions. We investigated asymmetry field centers that were 3 cm and 5 cm away from the isocenter, as well as performing the standard Winston-Lutz test. We used a special beam configuration to acquire images while avoiding collision, and we investigated both jaw and multileaf collimation. Results: For the jaw collimator setting, at 3 cm off-isocenter, the mechanical field deviated from the radiation field by about 2.5 mm; at 5 cm, the deviation was above 3 mm, up to 4.27 mm. For the multileaf collimator setting, at 3 cm off-isocenter, the deviation was below 1 mm; at 5 cm, the deviation was above 1 mm, up to 1.72 mm, which is 72% higher than the tolerance threshold. Conclusion: These results indicated that the further the asymmetry field center is from the machine isocenter, the larger the deviation of the mechanical field from the radiation field, and the distance between the center of the asymmetry field and the isocenter should not exceed 3 cm in of our clinic. We recommend that every clinic that uses linear accelerator, multileaf collimator-based SRS/SBRT perform the off-isocenter Winston-Lutz test in addition to the standard Winston-Lutz test and use their own deviation data to design the treatment plan.

60 APPLIED LIFE SCIENCES↗

Methods for studying the coherent 4D structural dynamics of free molecules and condensed state of matter

Studies in the coupled 4D spatial and temporal continuum are necessary for understanding the dynamic features of molecular systems with a complex profile of the potential energy surface. The introduction of time sweep into diffraction methods and the development of principles for studying coherent processes have revealed new approaches to the analysis of the dynamics of wave packets, the intermediate products and the transition state of the reaction center, and short-lived compounds in gaseous and condensed media. The use of picosecond and femtosecond electron probe pulses, synchronized with excitation laser pulses, determined the development of ultrafast electron crystallography, time-resolved X-ray diffraction, and dynamic transmission electron microscopy (DTEM). One of the most promising applications of the developed diffraction methods is the characterization and visualization of the processes occurring upon the photoexcitation of free molecules and biological objects and the analysis of surface and thin films. The whole set of spectral and diffraction methods based on different physical principles, which are complementary and make it possible to perform the photoexcitation of nuclei and electrons and carry out diagnostics of their dynamics at ultrashort time sequences, reveal new possibilities for studies with the necessary integration of the 'structure-dynamics-function' triad in chemistry, biology, and materials science.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Sequentially calibrating a Bayesian microsimulation model to incorporate new information and assumptions

Background: Microsimulation models are mathematical models that simulate event histories for individual members of a population. They are useful for policy decisions because they simulate a large number of individuals from an idealized population, with features that change over time, and the resulting event histories can be summarized to describe key population-level outcomes. Model calibration is the process of incorporating evidence into the model. Calibrated models can be used to make predictions about population trends in disease outcomes and effectiveness of interventions, but calibration can be challenging and computationally expensive. Methods: This paper develops a technique for sequentially updating models to take full advantage of earlier calibration results, to ultimately speed up the calibration process. A Bayesian approach to calibration is used because it combines different sources of evidence and enables uncertainty quantification which is appealing for decision-making. We develop this method in order to re-calibrate a microsimulation model for the natural history of colorectal cancer to include new targets that better inform the time from initiation of preclinical cancer to presentation with clinical cancer (sojourn time), because model exploration and validation revealed that more information was needed on sojourn time, and that the predicted percentage of patients with cancers detected via colonoscopy screening was too low. Results: The sequential approach to calibration was more efficient than recalibrating the model from scratch. Incorporating new information on the percentage of patients with cancers detected upon screening changed the estimated sojourn time parameters significantly, increasing the estimated mean sojourn time for cancers in the colon and rectum, providing results with more validity. Conclusions: A sequential approach to recalibration can be used to efficiently recalibrate a microsimulation model when new information becomes available that requires the original targets to be supplemented with additional targets.

60 APPLIED LIFE SCIENCES↗

Progress in Development of Electrochemical Methods in Corrosion Science and Engineering

The role and impact of four electrochemical techniques in the study of various corrosion applications are discussed, these are: scanning vibrating electrode technique (SVET), coupled multi-electrode array (CMEA) technique, scanning electrochemical microscope (SECM) and atomic emission spectroelectrochemistry (AESEC). A common theme is an ability to monitor corrosion phenomena in situ on a local electrochemical scale with high resolution of electrochemical and, in some cases, chemical reaction rates. In all cases, the techniques presented here are discussed in the context of specific corrosion problems carried out in full immersion conditions. Examples taken from the current literature, and new data, are presented to demonstrate the use and advantages of these techniques, or a combination of these techniques, as powerful tools for industrially important applications. Here, this includes: assessment of the galvanic interactions and throwing-power of metal-rich primer coatings for active corrosion protection, corrosion/corrosion resistance mechanisms of new metal alloys, the effect of pretreatments on coating integrity, current distributions within a crevice and pitting corrosion.

AESEC↗

Metal-to-Ceramic Joining Methods to Support Development of Advanced Ceramic-Based CSP Components

The National Renewable Energy Laboratory, Missouri University of Science and Technology (MS&T), Massachusetts Institute of Technology (MIT), and Colorado School of Mines (CSM) collaborated to design, develop, and test a material concept at bench scale which will be used to achieve a ceramic-to-metal (C2M) joint between a selected metal HTF loop material and a selected ceramic material used by the Gen3 CSP technology pathway. The final joint assembly will need to possess sufficient mechanical properties to withstand static high-temperature (650 degrees-700 degrees C) and high-pressure (20 MPa) and thermal cycling (between 650 degrees C and 100 degrees C) conditions. The material concept consists of three key components: (1) a ceramic matrix composite (CMC) that serves as a compliant transition material aiming to mitigate the stresses due to the mismatch of coefficient of thermal expansion (CTE) from a direct ceramic-to-metal joint, (2) a metal-end joint utilizing a multi-principal element alloy (MPEA) with changing percentage of particle loading to bond the candidate metal to the CMC, and (3) a ceramic-end joint utilizing a glass ceramic to bond the candidate ceramic to the CMC.

14 SOLAR ENERGY↗

Selecting the Gear Ratio of the Final Drive in Light Caterpillar Vehicles

Analysis of kinematic systems, final-drive designs, and the characteristics of the components permits the development of a method of selecting the gear ratio of the final drive and computer calculation of the strength of its components in a light caterpillar vehicle as a function of the gear ratio of the final drive and the speed of its components. A method is developed for assessing the calculations in terms of the basic strength parameters, so as to ensure rapid calculations with changes in the components, materials, speeds, and loads.

42 ENGINEERING↗

Sampling Microbial Dynamics in the Salish Sea Estuary: Evaluating Methods to Capture Cyanobacteria and Cyanophage

Introduction: Picocyanobacteria from the genera Prochlorococcus and Synechococcus thrive across the globe in aquatic environments, have relatively small genomes, and have growth dynamics regulated by both viral interactions and abiotic conditions, making them excellent model organisms for exploring host-pathogencoevolution. Methods: We developed and refined methods to sample and sequence cyanobacteria, cyanophages, and measured features of their abiotic environment. Results: The protocol described herein can successfully discriminate large-cell eukaryotic organisms, but size fractionation of picocyanobacteria appears to be affected by the presence of free DNA, multicellular structures, and abundant tycheposons. Our preferred final protocol from this exploratory effort included a combination of in-line and single vacuum flask filtrations, which reduced filtration processing time by over threefold in some cases compared to other tested methods, such as a fully in-line sequence or in-site filtrations. We successfully extracted an average of approximately 400–1200 ng for all filter fractions, with some variations between kits. Discussion: The protocol described herein can successfully discriminate large-cell eukaryotic organisms, but size fractionation of picocyanobacteria appears to be affected by the presence of free DNA, multicellular structures, and abundant tycheposons.

Salish Sea↗

Evolutionary optimization of interatomic potentials using genetic programming.

After more than 50 years of molecular simulations, accurate empirical models are still the bottleneck in the wide adoption of simulation techniques. Addressing this issue with a fresh paradigm is the need of the day. In this study, we outline a new genetic-programming based method to develop empirical models for a system purely from its energy and/or forces. While the approach was initially developed for the development of classical force-fields from ab-initio calculations, we also discuss its application to the molecular coarse-graining of methanol. Two models, one representing methanol by a single site and the other via two sites will be developed using this method. They will be validated against existing coarse-grained potentials for methanol by comparing thermophysical properties.

10 SYNTHETIC FUELS↗