Search NASA⌕ Search

SEARCH · Search NASA

Results for “Microprobe”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

1,755 records · Page 98

Laser nitriding for niobium superconducting radio-frequency accelerator cavities

Particle accelerators are a key tool for scientific research ranging from fundamental studies of matter to analytical studies at light sources. Cost-forperformance is critical, both in terms of initial capital outlay and ongoing operating expense, especially for electricity. It depends on the niobium superconducting radiofrequency (SRF) accelerator cavities at the heart of most of these machines. Presently Nb SRF cavities operate near 1.9 K, well (and expensively) below the 4.2 K atmospheric boiling point of liquid He. Transforming the 40 nm thick active interior surface layer from Nb to delta NbN (Tc = 17 K instead of 9.2 K) appears to be a promising approach. Traditional furnace nitriding appears to have not been successful for this. Further, exposing a complete SRF cavity to the time-temperature history required for nitriding risks mechanical distortion. Gas laser nitriding instead has been applied successfully to other metals [P.Schaaf, Prog. Mat. Sci. 47 (2002) 1]. The beam dimensions and thermal diffusion length permit modeling in one dimension to predict the time course of the surface temperature for a range of per-pulse energy densities. As with the earlier work, we chose conditions just sufficient for boiling as a reference point. We used a Spectra Physics HIPPO nanosecond laser (l = 1064 nm, Emax= 0.392 mJ, beam spot@ 34 microns, PRF =15 – 30 kHz) to obtain an incident fluence of 1.73 - 2.15 J/cm2 for each laser pulse at the target. The target was a 50 mm diameter SRF-grade Nb disk maintained in a nitrogen atmosphere at a pressure of 550 – 625 torr and rotated at a constant speed of 9 rpm. The materials were examined by scanning electron microscopy (SEM), electron probe microanalysis (EPMA) and x-ray diffraction (XRD). The SEM images show a sharp transition with fluence from a smooth, undulating topography to significant roughening, interpreted here as the onset of ablation. EPMA measurements of N/Nb atom ratio as a function of depth found a constant value to depths greater than the SRF active layer thickness. Certain irradiation conditions resulted in values consistent with formation of delta NbN. Under certain irradiation conditions, XRD data were consistent only with delta NbN on top of Nb metal. Funding: authored by Jefferson Science Associates LLC under US DOE Contract De-AC05-06OR23177. We are indebted to Prof. P. Schaaf (Goettingen) for the simulation code and helpful discussions.

36 MATERIALS SCIENCE↗

Synthesis and characterization of PuPO4—a potential analytical standard for EPMA actinide quantification

Transmutation nuclear fuels contain weight percentage quantities of actinide elements, including Pu, Am and Np. Because of the complex spectra presented by actinide elements using electron probe microanalysis (EPMA), it is necessary to have relatively pure actinide element standards to facilitate overlap correction and accurate quantitation. Synthesis of actinide oxide standards is complicated by their multiple oxidation states, which can result in inhomogeneous standards or standards that are not stable at atmospheric conditions. Synthesis of PuPO4 results in a specimen that exhibits stable oxidation-reduction chemistry, is beam stable, and is sufficiently homogenous to serve as an EPMA standard. This approach shows promise as a method for producing viable actinide standards for microanalysis.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Flux growth and magnetic properties of FeVO{sub 4} single crystals

FeVO{sub 4} (I) single crystals are grown by the flux method using V{sub 2}O{sub 5} as the self-flux. The grown crystals exhibit a characteristic morphology with natural facets. The quality of the crystals is confirmed by X-ray diffraction and EPMA techniques. Magnetic properties are investigated by means of magnetic susceptibility, magnetization, and heat capacity measurements. Two magnetic phase transitions are observed at {approx}13 and {approx}20 K. Such unusual magnetic behaviors are suggested to originate from two different Fe ligand environments of octahedral FeO{sub 6} and trigonal bipyramidal FeO{sub 5} in a six-column doubly bent chain. - Graphical abstract: FeVO{sub 4} (I) single crystals are grown by the flux method using V{sub 2}O{sub 5} as the self-flux. Magnetic properties are investigated by means of magnetic susceptibility, magnetization, and heat capacity measurements, showing two magnetic phase transitions at {approx}13 and {approx}20 K.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Magnetic properties of Co{sub 2}V{sub 2}O{sub 7} single crystals grown by flux method

Based on the phase diagram of CoO-V{sub 2}O{sub 5} system, single crystals of Co{sub 2}V{sub 2}O{sub 7} are grown using V{sub 2}O{sub 5} as self-flux at a slow cooling rate. The quality of grown crystals is analyzed by X-ray powder diffraction and electron probe microanalysis techniques. Magnetic properties are investigated by means of susceptibility, magnetization, and heat capacity measurements. Our experimental results suggest that Co{sub 2}V{sub 2}O{sub 7} is a three-dimensional antiferromagnet, in which two magnetic transitions may occur at low temperature and a spin-flop-like transition may occur at the applied field along the b-axis. By contrast to Ni{sub 2}V{sub 2}O{sub 7}, it is suggested that similar and different magnetic properties may arise from their similar crystal structures and different magnetic ions, respectively. - Abstract: Single crystals of Co{sub 2}V{sub 2}O{sub 7} are grown using V{sub 2}O{sub 5} as self-flux at a slow cooling rate. Magnetic properties are investigated by means of susceptibility, magnetization, and heat capacity measurements, showing that Co{sub 2}V{sub 2}O{sub 7} is likely to be a three-dimensional antiferromagnet with two magnetic transitions at low temperature. Display Omitted

36 MATERIALS SCIENCE↗

Chemical Characterization and Removal of Carbon-14 from Irradiated Graphite II - 13023

Approximately 250,000 tonnes of irradiated graphite waste exists worldwide and that quantity is expected to increase with decommissioning of Generation II reactors and deployment of Generation IV gas-cooled, graphite moderated reactors. This situation indicates the need for a graphite waste management strategy. Of greatest concern for long-term disposal of irradiated graphite is carbon-14 (C-14), with a half-life of 5730 years. Study of irradiated graphite from some nuclear reactors indicates C-14 is concentrated on the outer 5 mm of the graphite structure. The aim of the research presented last year and updated here is to identify the chemical form of C-14 in irradiated graphite and develop a practical method by which C-14 can be removed. A nuclear-grade graphite, NBG-18, and a high-surface-area graphite foam, POCOFoam{sup R}, were exposed to liquid nitrogen (to increase the quantity of C-14 precursor) and neutron-irradiated (10{sup 13} neutrons/cm{sup 2}/s). Finer grained NBG-25 was not exposed to liquid nitrogen prior to irradiation at a neutron flux on the order of 10{sup 14} /cm{sup 2}/s. Characterization of pre- and post-irradiation graphite was conducted to determine the chemical environment and quantity of C-14 and its precursors via the use of surface sensitive characterization techniques. Scanning Electron Microscopy (SEM) was used to evaluate the morphological features of graphite samples. The concentration, chemical composition, and bonding characteristics of C-14 and its precursors were determined through X-ray Photoelectron Spectroscopy (XPS), Time-of-Flight Secondary Ion Mass Spectrometry (SIMS), and Energy Dispersive X-ray Analysis Spectroscopy (EDX). Results of post-irradiation characterization of these materials indicate a variety of surface functional groups containing carbon, oxygen, nitrogen and hydrogen. During thermal treatment, irradiated graphite samples are heated in the presence of an inert carrier gas (with or without oxidant gas), which carries off gaseous products released during treatment. Graphite gasification occurs via interaction with adsorbed oxygen complexes. Experiments in argon were performed at 900 deg. C and 1400 deg. C to evaluate the selective removal of C-14. Thermal treatment also was performed with the addition of 3 and 5 volume % oxygen at temperatures 700 deg. C and 1400 deg. C. Thermal treatment experiments were evaluated for the effective selective removal of C-14. Lower temperatures and oxygen levels correlated to more efficient C-14 removal. (authors)

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Partitioning of fission products from irradiated nitride fuel using inductive vaporization

Irradiated nitride fuel (Pu{sub 0.3}Zr{sub 0.7})N fabricated at PSI in frame of the CONFIRM project and having a burn-up of 10.4 % FIMA (Fission per Initial Metal Atom) has been investigated by means of inductive vaporization. The study of thermal stability and release behavior of Pu, Am, Zr and fission products (FPs) was performed in a wide temperature range (up to 2300 C. degrees) and on different redox conditions. On-line monitoring by ICP-MS detected low nitride stability and significant loss of Pu and Am at T>1900 C. degrees during annealing under inert atmosphere (Ar). The oxidative pre-treatment of nitride fuel on air at 1000 C. degrees resulted in strong retention of Pu and Am in the solid, as well as of most FPs. Thermodynamic modelling of elemental speciation using GEM-Selektor v.3 code (Gibbs Energy Minimization Selektor), supported by a comprehensive literature review on thermodynamics of actinides and FPs, revealed a number of binary compounds of Cs, Mo, Te, Sr and Ba to occur in the solid. Speciation of some FPs in the fuel is discussed and compared to earlier results of electron probe microanalysis (EPMA). Predominant vapor species predicted by GEM-Selektor calculations were Pu(g), Am(g) and N{sub 2}. Nitrogen can be completely released from the fuel after complete oxidation at 1000 C. degrees. With regard to the irradiated nitride reprocessing technology, this result can have an important practical application as an alternative way for {sup 15}N recovery. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Chemical Characterization and Removal of C-14 from Irradiated Graphite-12010

Quantities of irradiated graphite waste are expected to drastically increase, which indicates the need for a graphite waste management strategy. Of greatest concern for long-term disposal of irradiated graphite is carbon-14 (C-14), with a half-life of 5730 years. Study of irradiated graphite from nuclear reactors indicates C-14 is concentrated on the outer 5 mm of the graphite structure. The aim of the research described here is to identify the chemical form of C-14 in irradiated graphite and develop a practical method by which C-14 can be removed. Characterization of pre- and post-irradiation graphite was conducted to determine bond type, functional groups, location and concentration of C-14 and its precursors via the use of surface sensitive characterization techniques. Because most surface C-14 originates from neutron activation of nitrogen, an understanding of nitrogen bonding to graphite may lead to a greater understanding of the formation pathway of C-14. However, no single technique provides a complete picture. Therefore, a portfolio of techniques has been developed, with each technique providing another piece to the puzzle that is the chemical nature of the C-14. Scanning Electron Microscopy (SEM), X-Ray Diffraction (XRD), and Raman Spectroscopy were used to evaluate the morphological features of graphite samples. The concentration, chemical composition, and bonding characteristics of C-14 and its precursors were determined through X-ray Photoelectron Spectroscopy (XPS), Time-of-Flight Secondary Ion Mass Spectrometry (SIMS), and Auger and Energy Dispersive X-ray Analysis Spectroscopy (EDX). High-surface-area graphite foam, POCOFoam{sup R}, was exposed to liquid nitrogen and irradiated. Characterization of this material has shown C-14 to C-12 ratios of 0.035. This information was used to optimize the thermal treatment of graphite. Thermal treatment of irradiated graphite as reported by Fachinger et al. (2007) uses naturally adsorbed oxygen complexes to gasify graphite, thus its effectiveness is highly dependent on the availability of adsorbed oxygen compounds. In research presented, the quantity and form of adsorbed oxygen complexes in pre- and post irradiated graphite was studied using SIMS and XPS. SIMS and XPS detected adsorbed oxygen compounds on both irradiated and unirradiated graphite. During thermal treatment graphite samples are heated in the presence of inert argon gas, which carries off gaseous products released during treatment. Experiments were performed at 900 deg. C and 1400 deg. C to evaluate the selective removal of C-14. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Nuclear fuel behavior at high temperature: new insights from post-test examinations on the VERDON-1 sample

In order to reduce the uncertainties concerning Source Term assessment under Light Water Reactor (LWR) severe accident conditions, 4 VERDON tests were recently performed. They have been defined in the framework of the International Source Term Program and carried out at CEA Cadarache, in the LECA-STAR facility. Among these 4 VERDON tests, VERDON-1 test was devoted to high burn-up UO{sub 2} fuel behavior and FP release under H{sub 2} reducing conditions at very high temperature. This test was performed with the Release Circuit, which is devoted to the precise characterization of the FP release, in terms of FP release kinetics and fission products (FPs) released fraction. The main components of the circuits are a furnace heating the fuel sample, a filter trapping the emitted aerosols and gamma spectrometry detectors for online and post-test measurements. VERDON-1 test was conducted up to about 2600 Celsius degrees without reaching global fuel relocation, allowing thereby post-test micro-analyses. After a brief description of the fuel sample nature and the experimental set-up, we present the progress of the experimental sequence and the associated gamma spectrometry measurements. We then focus on the major results of the VERDON-1 tests regarding the fuel global behavior. These results are obtained by two complementary techniques. First, the fuel sight gamma station can be used either on-line to detect fuel relocation or just after the test, as a longitudinal bench, to get preliminary information on the global shape of the fuel sample inside the furnace. Secondly, these information are completed by post-test examinations performed on the fuel sample after extraction from the furnace. Complete qualitative and quantitative characterizations, including EPMA (Electron Probe Micro-Analysis) and SEM (Scanning Electron Microscopy) analysis, were performed for the first time at the CEA Cadarache on a sample that has been submitted to such severe accident conditions. These results show an advanced state of sample degradation, with locally previously molten areas, meaning that fuel global relocation was imminent by the end of thermal-hydraulic sequence. The relocation temperature is compared to that of previous VERCORS tests and discussed regarding the atmosphere of the test and possible UO{sub 2}-ZrO{sub 2} interaction. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Managing age-related changes in device radiation-response.

Aging effects in silicon electronics are a concern for systems with prolonged service lives that contain electronics not easily accessible for testing and replacement. Such effects are especially difficult to assess for components that must be exposed to, and function in, transient radiation environments. A methodology has been developed that utilizes electrical parametric and non-destructive laser testing techniques, charge collection microscopy, and controlled-environment storage to permit periodic reassessment of the state of health of such electronics. The use of a scanned, focused laser, charge collection microscopy technique, developed to detect the onset of change and then track these changes in charge collection efficiency with micron resolution, will be described. These results are then used to direct subsequent failure analyses using high-sensitivity, high spatial resolution materials analysis techniques, (such as Time-of-Flight SIMS), in order to identify the underlying material driver of the aging. It will be shown how the results of this methodology are used to create finite-element, charge transport, device models of age-affected devices, and how the time-dependence of the underlying material change is incorporated into the device aging model, so as to predict the future rate, and end-state, of the identified device aging process. Lastly the model is validated using wavelength-dependent charge collection microscopy measurements of the device's response.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗