Search NASA⌕ Search

SEARCH · Search NASA

Results for “Nuclear Science”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,765 records · Page 98

Low background techniques in XMASS

The XMASS project aims to detect pp and {sup 7}Be solar neutrinos, neutrino-less double beta decay, and dark matter searches using ultra-pure liquid xenon. The first stage of XMASS project is concentrated on dark matter searches using 800 kg liquid xenon detector which requires low background and low threshold. Several techniques applied to XMASS detector for low background will be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Investigation Of Exotic Shapes, Correlations And Isomers In Nuclei With Large Compton Suppressed Clover Array

An array is designed for 24 Compton suppressed clover detectors. Recent results from the array will be presented which highlights the structure of nuclei in A {approx} 110 and 130 region and investigation of different reactions dynamics. The perspectives offered by the forthcoming operation of the clover array coupled to a new digital data acquisition system are also discussed briefly.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multi-Channel Integrated Circuits For Use In Research With Radioactive Ion Beams

The Integrated Circuits Design Research Laboratory at Southern Illinois University Edwardsville (SIUE) has been collaborating over the past several years with the Nuclear Reactions Group at Washington University (WU) on the development of a family of custom, multi-channel Integrated Circuits (ICs). To date, the collaboration has successfully produced two micro-chips. The first was an analog shaped and peak sensing chip known as HINP16C (Heavy Ion Nuclear Physics--16 Channel). The second chip, christened PSD8C (Pulse Shape Discrimination--8 Channel), was designed to logically complement (in terms of detector types) the HINP16C chip. The HINP16C chip, for use with solid-state detectors, produces sparsified analog pulse trains for both linear (pulse height) and timing (relative to an external reference) signals. A shaper and peak detector are implemented in the linear branch, and a pseudo Constant-Fraction Discriminator (CFD) and Time-to-Voltage Converter (TVC) are implemented in the logic/timing branch. The internal and external gain options make the chip suitable for use in a wide variety of applications. PSD8C greatly simplifies the pulse-processing electronics needed for large arrays of scintillation detectors. As the PSD8C employs user-controlled, multi-region charge integration, particle identification is inherent in the design. Each of the three pulse-height sub-channels consists of a gated integrator with eight programmable charging rates and an externally programmable gate generator that defines the start (with 4 time ranges) and the width (with 4 time ranges) of the gate, relative to an external discriminator signal. Moreover, each channel on the chip also contains a TVC. This paper describes the design, capabilities, and features of the HINP16C and PSD8C ICs along with a description of how the chips are being used. It also discusses modifications and enhancements which have been made to both chips and their associated prototypical systems in order to improve ease of use and increase performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Lessons Learned In Developing The VACIS Products

SAIC's development of VACIS provides useful 'lessons learned' in bridging the gap from an idea to a security or contraband detection product. From a gamma densitometer idea for solving a specific Customs Service (CS) requirement (detection of drugs in near-empty tanker trucks) in mid-1990's, SAIC developed a broad line of vehicle and cargo inspections systems (over 500 systems deployed to date) based on a gamma-ray radiographic imaging technique. This paper analyzes the reasons for the successful development of VACIS and attempts to identify ''lessons learned'' useful for future security and contraband detection product developments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MUSETT and the Spectroscopy of Heavy Elements at GANIL

The new MUSETT silicon-wall has been built to study and obtain detailed spectroscopic information on the transfermium and transactinide elements. MUSETT is located at GANIL at the detection plane of VAMOS, the latter coupled with the EXOGAM germanium array. Results from the in-beam commissioning are reported and an overview of our future experimental program will be given.

43 PARTICLE ACCELERATORS↗

Development of a Micromegas TPC for Low Energy Heavy Ions Measurement for Nuclear Fission and Astrophysics Applications

Time Projection Chambers are widely used since many years for tracking and identification of charged particles in high energy physics. We present a new R and D project to investigate the feasibility of a Micromegas TPC for low energy heavy ions detection. Two physics cases are relevant for this project. The first is the study of the nuclear fission of actinides by measuring the fission fragments properties (mass, nuclear charge, kinetic energy) that will be performed at different installations and in particular at the NFS facility to be built in the framework of the SPIRAL2 project in GANIL. The second physics case is the study of heavy ion reactions, like ({alpha},{gamma}), ({alpha},p), ({alpha},n) and all the inverse reactions in the energy range between 1.5 and 3 AMeV using both stable and radioactive beams. These reactions have a key role in p process in nuclear astrophysics to explain the synthesis of heavy proton-rich nuclei. Within the project, a large effort is devoted to Monte-Carlo simulations and a detailed benchmark of different simulation codes on the energy loss and range in gas of heavy ions at low energy has been performed. A new approach for simulating the ion charge state evolution in GEANT4 is also presented. Finally, preliminary results of an experimental test campaign on prototype are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nuclear Fission Investigation with Twin Ionization Chamber

The purpose of the present paper was to report the recent results, obtained in development of digital pulse processing mathematics for prompt fission neutron (PFN) investigation using twin ionization chamber (TIC) along with fast neutron time-of-flight detector (ND). Due to well known ambiguities in literature (see refs. [4, 6, 9 and 11]), concerning a pulse induction on TIC electrodes by FF ionization, we first presented detailed mathematical analysis of fission fragment (FF) signal formation on TIC anode. The analysis was done using Ramo-Shockley theorem, which gives relation between charged particle motion between TIC electrodes and so called weighting potential. Weighting potential was calculated by direct numerical solution of Laplace equation (neglecting space charge) for the TIC geometry and ionization, caused by FF. Formulae for grid inefficiency (GI) correction and digital pulse processing algorithms for PFN time-of-flight measurements and pulse shape analysis are presented and discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and Fabrication of Cherenkov Counters for the Detection of SNM

The need for large-size detectors for long-range active interrogation (AI) detection of SNM has generated interest in water-based detector technologies. Water Cherenkov Detectors (WCD) were selected for this research because of their transportability, scalability, and an inherent energy threshold. The detector design and analysis was completed using the Geant4 toolkit. It was demonstrated both computationally and experimentally that it is possible to use WCD to detect and characterize gamma rays. Absolute efficiency of the detector (with no energy cuts applied) was determined to be around 30% for a {sup 60}Co source.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of Monoenergetic Low Energy Neutron Fields with the {mu}TPC Detector

The AMANDE facility produces monoenergetic neutron fields from 2 keV to 20 MeV for metrological purposes. To be considered as a reference facility, fluence and energy distributions of neutron fields have to be determined by primary measurement standards. For this purpose, a micro Time Projection Chamber is being developed to be dedicated to measure neutron fields with energy ranging from 2 keV up to 1 MeV. We present simulations showing that such a detector, which allows the measurement of the ionization energy and the 3D reconstruction of the recoil nucleus, provides the determination of neutron energy and fluence of such low energy neutron fields.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Recent Developments in Fast Neutron Detection and Multiplicity Counting with Liquid Scintillator

For many years, LLNL researchers have been developing time-correlated neutron detection techniques and algorithms for applications such as Arms Control, Threat Detection and Nuclear Material Assay. Many of the techniques have been developed specifically for the relatively low efficiency (a few percent) attainable by detector systems limited to man-portability. Historically, thermal neutron detectors (mainly {sup 3}He) were used, taking advantage of the high thermal neutron interaction cross sections. More recently, we have been investigating the use of fast neutron detection with liquid scintillators, inorganic crystals, and in the near future, pulse-shape discriminating plastics that respond over 1000 times faster (ns versus tens of {mu}s) than thermal neutron detectors. Fast neutron detection offers considerable advantages since the inherent ns production timescales of spontaneous fission and neutron-induced fission are preserved and measured instead of being lost by thermalization required for thermal neutron detectors. We are now applying fast neutron technology to the safeguards regime in the form of fast portable digital electronics as well as faster and less hazardous scintillator formulations. Faster detector response times and sensitivity to neutron momentum show promise for measuring, differentiating, and assaying samples that have modest to very high count rates, as well as mixed fission sources like Cm and Pu. We report on measured results with our existing liquid scintillator array and progress on the design of a nuclear material assay system that incorporates fast neutron detection, including the surprising result that fast liquid scintillator detectors become competitive and even surpass the precision of {sup 3}He-based counters measuring correlated pairs in modest (kg) samples of plutonium.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Deuterated Liquid Scintillators: A New Tool for Neutron Measurements

The response of large (4x6) deuterated liquid scintillators (up to 10 cm diameter by 15 cm) to neutrons in the energy range from 0.5 MeV to 20 MeV has been studied using several nuclear reactions, including d(d,n), and {sup 12}C(d,n){sup 13}N, at the University of Notre Dame FN tandem accelerator. The latter two reactions utilized 9 MeV and 16 MeV deuteron beams, including a pulsed beam that also permitted time-of-flight (ToF) measurements. Combining pulse-shape discrimination and (ToF) allows gating on specific neutron energy groups to determine the detector response to specific neutron energies. Newly-obtained and optimized pulse shape discrimination using digitized pulse analysis from these detectors will be presented in this paper. These measurements confirmed the ability of these detectors to provide useful neutron spectra without ToF.

43 PARTICLE ACCELERATORS↗

Noble Gas Excimer Detectors for Security and Safeguards Applications

Noble gas excimer detectors are a technology that is common in particle physics research and less common in applications for security and international safeguards. These detectors offer the capability to detect gammas with an energy resolution similar to NaI and to detect neutrons with good energy resolution as well. Depending on the noble gas selected and whether or not it is in a gaseous or liquid state, the sensitivity to gammas and neutrons can be tuned according to the needs of the application. All of this flexibility can be available at a significant cost saving over alternative technologies. This paper will review this detector technology and its applicability to security and safeguards.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nondestructive identification of isotopes using nuclear resonance fluorescence

Nondestructive identification of heavy isotopes concealed in a thick iron box has been demonstrated by using nuclear resonance fluorescence. A quasi-monochromatic photon beam produced by the collision of laser quanta with high energy electrons was used for resonant excitation of nuclear levels in {sup 206}Pb and {sup 208}Pb. By measuring the resonant {gamma} rays emitted from {sup 206}Pb and {sup 208}Pb, each of these isotopes were clearly identified. The ratio of the effective thickness, i.e., concentration distribution, of these isotopes was deduced from the relative intensities of the measured nuclear resonance fluorescence strengths.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A neutron diagnostic for high current deuterium beams

A neutron diagnostic for high current deuterium beams is proposed for installation on the spectral shear interferometry for direct electric field reconstruction (SPIDER, Source for Production of Ion of Deuterium Extracted from RF plasma) test beam facility. The proposed detection system is called Close-contact Neutron Emission Surface Mapping (CNESM). The diagnostic aims at providing the map of the neutron emission on the beam dump surface by placing a detector in close contact, right behind the dump. CNESM uses gas electron multiplier detectors equipped with a cathode that also serves as neutron-proton converter foil. The cathode is made of a thin polythene film and an aluminium film; it is designed for detection of neutrons of energy >2.2 MeV with an incidence angle < 45 deg. CNESM was designed on the basis of simulations of the different steps from the deuteron beam interaction with the beam dump to the neutron detection in the nGEM. Neutron scattering was simulated with the MCNPX code. CNESM on SPIDER is a first step towards the application of this diagnostic technique to the MITICA beam test facility, where it will be used to resolve the horizontal profile of the beam intensity.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Extreme ultraviolet spectroscopy and modeling of Cu on the SSPX Spheromak and laser plasma 'Sparky'

Impurities play a critical role in magnetic fusion research. In large quantities, impurities can cool and dilute plasma creating problems for achieving ignition and burn; however in smaller amounts the impurities could provide valuable information about several plasma parameters through the use of spectroscopy. Many impurity ions radiate within the extreme ultraviolet (EUV) range. Here, we report on spectra from the silver flat field spectrometer, which was implemented at the Sustained Spheromak Physics experiment (SSPX) to monitor ion impurity emissions. The chamber within the SSPX was made of Cu, which makes M-shell Cu a prominent impurity signature. The Spect3D spectral analysis code was utilized to identify spectral features in the range of 115-315 A and to more fully understand the plasma conditions. A second set of experiments was carried out on the compact laser-plasma x-ray/EUV facility 'Sparky' at UNR, with Cu flat targets used. The EUV spectra were recorded between 40-300 A and compared with results from SSPX.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multi-shot analysis of the gamma reaction history diagnostic

The gamma reaction history diagnostic at the National Ignition Facility has the capability to determine a number of important performance metrics for cryogenic deuterium-tritium implosions: the fusion burn width, bang time and yield, as well as the areal density of the compressed ablator. Extracting those values from the measured {gamma} rays of an implosion, requires accounting for a {gamma}-ray background in addition to the impulse response function of the instrument. To address these complications, we have constructed a model of the {gamma}-ray signal, and are developing a simultaneous multi-shot fitting routine to constrain its parameter space.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗