Search NASA⌕ Search

SEARCH · Search NASA

Results for “Performance Deviation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,765 records · Page 98

TU-FG-BRB-06: A Prompt Gamma-Ray Spectroscopy System for Clinical Studies of in Vivo Proton Range Verification

Purpose: We present a new system to perform prompt gamma-ray spectroscopy during proton pencil-beam scanning treatments, which enables in vivo verification of the proton range. This system will be used for the first clinical studies of this technology. Methods: After successful pre-clinical testing of prompt gamma-ray spectroscopy, a full scale system for clinical studies is now being assembled. Prompt gamma-rays will be detected during patient treatment using an array of 8 detector modules arranged behind a tungsten collimator. Each detector module consists of a lanthanum(III) bromide scintillator, a photomultiplier tube, and custom electronics for stable high voltage supply and signal amplification. A new real-time data acquisition and control system samples the signals from the detectors with analog-to-digital converters, analyses events of interest, and communicates with the beam delivery systems. The timing of the detected events was synchronized to the cyclotron radiofrequency and the pencil-beam delivery. Range verification is performed by matching measured energy- and timeresolved gamma-ray spectra to nuclear reaction models based on the clinical treatment plan. Experiments in phantoms were performed using clinical beams in order to assess the performance of the systems. Results: The experiments showed reliable real-time analysis of more than 10 million detector events per second. The individual detector modules acquired accurate energy- and time-resolved gamma-ray measurements at a rate of 1 million events per second, which is typical for beams delivered with a clinical dose rate. The data acquisition system successfully tracked the delivery of the scanned pencil-beams to determine the location of range deviations within the treatment field. Conclusion: A clinical system for proton range verification using prompt gamma-ray spectroscopy has been designed and is being prepared for use during patient treatments. We anticipate to start a first clinical study in the near future. This work was supported by the Federal Share of program income earned by Massachusetts; General Hospital on C06-CA059267, Proton Therapy Research and Treatment Center.

60 APPLIED LIFE SCIENCES↗

Measurements of electroweak production of a photon in association with two jets in proton-proton collisions at $\sqrt{s}=13$ TeV

The first observation of electroweak production of a photon in association with two forward jets in proton-proton collisions is presented. The measurement uses data recorded by the CMS experiment at the LHC during 2016–2018 at a center-of-mass energy of 13 TeV, corresponding to an integrated luminosity of 138 fb −1 . The analysis is performed in a region enriched in photon production via vector boson fusion, with a requirement on the transverse momentum of the photon to exceed 200 GeV. The cross section is measured to be ${202}_{-32}^{+36}$ fb, at a significance with respect to the null hypothesis that exceeds five standard deviations. This is in agreement with the standard model prediction of ${177}_{-12}^{+13}$ fb. Differential cross sections are measured as a function of various observables. Limits are set on dimension-6 effective field theory operators that contribute to the WW γ interaction. The observed 95% confidence intervals for the corresponding Warsaw basis Wilson coefficients c W and c HWB are [−0.11, 0.16] and [−1.6, 1.5], respectively.

electroweak interaction↗

A Deep-Learning System for Fully-Automated Peripherally Inserted Central Catheter (PICC) Tip Detection

A peripherally inserted central catheter (PICC) is a thin catheter that is inserted via arm veins and threaded near the heart, providing intravenous access. The final catheter tip position is always confirmed on a chest radiograph (CXR) immediately after insertion since malpositioned PICCs can cause potentially life-threatening complications. Although radiologists interpret PICC tip location with high accuracy, delays in interpretation can be significant. In this study, we proposed a fully-automated, deep-learning system with a cascading segmentation AI system containing two fully convolutional neural networks for detecting a PICC line and its tip location. A preprocessing module performed image quality and dimension normalization, and a post-processing module found the PICC tip accurately by pruning false positives. Our best model, trained on 400 training cases and selectively tuned on 50 validation cases, obtained absolute distances from ground truth with a mean of 3.10 mm, a standard deviation of 2.03 mm, and a root mean squares error (RMSE) of 3.71 mm on 150 held-out test cases. This system could help speed confirmation of PICC position and further be generalized to include other types of vascular access and therapeutic support devices.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effect of loading path on grain misorientation and geometrically necessary dislocation density in polycrystalline aluminum under reciprocating shear

Solid phase processing (SPP) is a promising alloy fabrication technique to produce fine and homogeneous grain structures for high-performance alloys. However, there is very limited modeling capability to understand and predict the grain refinement during SPP. In this work, the crystal plasticity theory was used to study elastic-plastic deformation in polycrystalline aluminums under large shear deformation. Two approaches, kernel averaged misorientation (KAM) and grain reference orientation deviation (GROD), were used to assess the grain misorientations. The geometrically necessary dislocation (GND) density was computed with the plastic strain rate. The deformation simulations were carried out under two loading conditions to investigate the effect of loading paths on the evolutions of grain misorientation and GND density. The results show that the regions with high misorientation and GND density first appear near grain boundaries. These regions then extend toward interior grains. The loading path affects dislocation system activation and dislocation recovery, hence dislocation evolution and misorientation. In conclusion, both two- and three-dimensional simulations showed that the spatial and temporal evolutions of GROD, KAM, and GND density in are closely correlated, which indicates they all can be used as criteria of grain refinement or recrystallization.

36 MATERIALS SCIENCE↗

Inexact convex relaxations for AC optimal power flow: Towards AC feasibility

Convex relaxations of AC optimal power flow (AC-OPF) problems have attracted significant interest as in several instances they provably yield the global optimum to the original non-convex problem. If, however, the relaxation is inexact, the obtained solution is not AC-feasible. The quality of the obtained solution is essential for several practical applications of AC-OPF, but detailed analyses are lacking in existing literature. Here, this paper aims to cover this gap. We provide an in-depth investigation of the solution characteristics when convex relaxations are inexact, we assess the most promising AC feasibility recovery methods for large-scale systems, and we propose two new metrics that lead to a better understanding of the quality of the identified solutions. We perform a comprehensive assessment on 96 different test cases, ranging from 14 to 3120 buses, and we show the following: (i) Despite an optimality gap of less than 1%, several test cases still exhibit substantial distances to both AC feasibility and local optimality and the newly proposed metrics characterize these deviations. (ii) Penalization methods fail to recover an AC-feasible solution in 15 out of 45 test cases. (iii) The computational benefits of warm-starting non-convex solvers have significant variation, but a computational speedup exists in over 75% of cases.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Simulation of Taylor flow evaporation for bubble-pump applications

Single-pressure absorption systems incorporate bubble-pump generators (BPGs) for refrigerant separation and passive fluid circulation. In conventional spot-heated BPGs, heat is transferred over a small area, requiring high source temperatures. Distributed-heated BPGs receive thermal input over most of the component surface, enabling low temperature operation. In this investigation, a Volume-of-Fluid phase-change simulation formulation is developed and validated. Here this approach is applied to the evaporating Taylor flow pattern in distributed-heated BPGs. A 2-D axisymmetric simulation is performed, which yields detailed information about the developing heat transfer and two-phase flow phenomena. Results are used to assess predicted trends and sub-models from a 1-D segmented BPG model. Close agreement is obtained between segmented model and simulation results for bubble rise velocity (5–7% deviation), bubble and slug lengths, void fraction (3%), and hydrodynamic pressure drop (18%). Specifying average Taylor bubble lengths from the simulation as an input to the segmented model reduces hydrodynamic pressure drop deviation to 6%. Simulated flow-evaporation heat transfer coefficients are significantly higher than those predicted using analytic models from the literature. A new flow evaporation heat transfer correlation that accounts for developing slug flow effects is proposed, and yields close agreement with simulation results for heat transfer coefficient (AAD = 11%) and overall heat transfer rate (2%). Overall, this investigation provides validation for a distributed-heated BPG modeling approach, which can enable passive refrigeration for diverse applications.

42 ENGINEERING↗

Evaluation and development of flow condensation correlations using the data from low GWP refrigerants in an axial micro-fin aluminum tube

To mitigate global warming, the world is transitioning to refrigerants with low global warming potential (GWP). Supporting this shift requires a model that can accurately predict the heat transfer and pressure drop of new refrigerants, crucial for designing efficient heat exchangers. Existing models, however, are largely based on currently deployed refrigerants and primarily developed for unexpanded micro-fin tubes with spiral angles of 6° to 30°. Their applicability to new refrigerants, especially in expanded micro-fin tubes, is uncertain. This study assesses the performance of four well-known condensation models for six emerging refrigerants—R-32, R-454B, R-454C, R-455A, R-1234yf, and R-1234ze(E)—against experimental data. Initially, the Han and Lee (2005) model shows the best prediction accuracy with a mean absolute deviation (MAD) of 22.1 %. To enhance the accuracy of heat transfer models for new refrigerants and geometries with large temperature glides, two approaches are proposed. Here, the first approach applies a simple correction factor, reducing the MAD of the Cavallini et al. (2009) model from 68.2 % to 15.4 %. The second approach uses the variable metric method for minimization, fitting new constants to the data. This optimization results in the Kedzierski and Goncalves (1997) model achieving the highest accuracy, with a MAD of 13.1 %. For pressure drop models, the Cavallini et al. (1997) model is the most accurate with a MAD of 6.4 %, followed by the Haraguchi et al. (1993) model with a MAD of 9.4 %. Due to its simplicity, the Haraguchi et al. (1993) model is a practical option for predicting frictional pressure drop.

Axial micro-fin tubes↗

Combined quantitative ultrasonic and time-resolved interaction force AFM imaging

The authors describe a method where quantitative ultrasonic atomic force microscopy (UAFM) is achieved during time-resolved interaction force (TRIF) imaging in intermittent contact mode. The method uses a calibration procedure for quantitative UAFM. It improves elasticity measurements of stiff regions of surfaces while retaining the capabilities of the TRIF mode for topography, adhesion, dissipation, and elasticity measurements on soft regions of sample surfaces. This combination is especially advantageous when measuring and imaging samples with broad stiffness range in a nondestructive manner. The experiments utilize an active AFM probe with high bandwidth and the UAFM calibration is performed by measuring the magnitude of the time-resolved UAFM signal at a judiciously chosen frequency for different contact stiffness values during individual taps. Improved sensitivity to stiff surface elasticity is demonstrated on a special sample. The results show that combining UAFM with TRIF provides 2.5 GPa (5%) standard deviation on the silicon surface reduced Young's modulus, representing 5x improvement over using only TRIF mode imaging.

42 ENGINEERING↗

Detection and imaging of the oxygen deficiency in single crystalline YBa{sub 2}Cu{sub 3}O{sub 7−δ} thin films using a scanning positron beam

Single crystalline YBa{sub 2}Cu{sub 3}O{sub 7−δ} (YBCO) thin films were grown by pulsed laser deposition in order to probe the oxygen deficiency δ using a mono-energetic positron beam. The sample set covered a large range of δ (0.191 < δ < 0.791) yielding a variation of the critical temperature T{sub c} between 25 and 90 K. We found a linear correlation between the Doppler broadening of the positron electron annihilation line and δ determined by X-ray diffraction. Ab-initio calculations have been performed in order to exclude the presence of Y vacancies and to ensure the negligible influence of potentially present Ba or Cu vacancies to the found correlation. Moreover, scanning with the positron beam allowed us to analyze the spatial variation of δ, which was found to fluctuate with a standard deviation of up to 0.079(5) within a single YBCO film.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Convection in Scaled Turbine Internal Cooling Passages With Additive Manufacturing Roughness

Abstract Additive manufacturing processes, such as direct metal laser sintering (DMLS), enable the creation of novel turbine cooling internal passages and systems. However, the DMLS method produces a significant and unique surface roughness. Previous work in scaled passages analyzed pressure losses and friction factors associated with the rough surfaces, as well as investigated the velocity profiles and turbulent flow characteristics within the passage. In this study, the heat transfer characteristics of scaled additively manufactured surfaces were measured using infrared (IR) thermography. Roughness panels were CNC machined from plates of aluminum 6061 to create near isothermal roughness elements when heated. Fluid resistance differences between the aluminum roughness panels and roughness panels constructed from ABS plastic using the same roughness patterns from McClain et al. (2020, “Flow in a Simulated Turbine Blade Cooling Channel With Spatially Varying Roughness Caused by Additive Manufacturing Orientation,” ASME Turbo Expo 2020, Turbomachinery Technical Conference and Exposition, Virtual Conference, Sept. 21–25, GT2020-16069) were investigated. Finally, the overall thermal performance enhancements and friction losses were assessed through the calculation of surface averaged “global thermal performance” ratios. The global thermal performance characterizations indicate results in-line with those found for traditional commercial roughness and slightly below traditional internal passage convection enhancement methods such as swirl chambers, dimples, and ribs. The passages investigated in this study do not include compressibility effects or the long-wavelength artifacts and channel geometric deviations observed by Wildgoose et al. (2020, “Impact of Additive Manufacturing on Internal Cooling Channels with Varying Diameters and Build Directions,” ASME Turbo Expo 2020, Turbomachinery Technical Conference and Exposition, Virtual Conference, Sept. 21–25, GT2020-15049). However, the results of this study indicate that, based on the roughness augmentation alone, artificial convective cooling enhancers such as turbulators or dimples may still be required for additively manufactured turbine component cooling.

Engineering↗

SU-E-T-120: Dosimetric Characteristics Study of NanoDotâ,,¢ for In-Vivo Dosimetry

Purpose: The purpose of the study was to analyze the dosimetric characteristics (energy dependence, reproducibility and dose linearity) of nanoDot™ optically stimulated luminescence dosimeters (OSLDs) and validate their potential use during in-vivo dosimetry, specifically TBI. The manufacturer stated accuracy is ±10% for standard nanoDot™. Methods: At AKUH, the InLight microStar OSL dosimetry system for patient in-vivo dosimetry is in use since 2012. Twenty-five standard nanoDot™ were used in the analysis. Sensitivity and reproducibility was tested in the first part with 6MV and 18 MV Varian x-ray beams. Each OSLD was irradiated to 100cGy dose at nominal SSD (100 cm). All the OSLDs were read 3 times for average reading. Dose linearity and calibration were also performed with same beams in common clinical dose range of 0 - 500 cGy. In addition, verification of TBI absolute dose at extended SSD (500cm) was also performed. Results: The reproducibility observed with the OSLD was better than the manufacturer stated limits. Measured doses vary less than ±2% in 19(76%) OSLDs, whereas less than ±3% in 6(24%) OSLDs. Their sensitivity was approximately 525 counts per cGy. Better agreement was observed between measurements, with a standard deviation of 1.8%. A linear dose response was observed with OSLDs for both 6 and 18MV beams in 0 - 500 cGy dose range. TBI measured doses at 500 cm SSD were also confirmed to be within ±0.5% and ±1.3% of the ion chamber measured doses for 6 and 18MV beams respectively. Conclusion: The dosimetric results demonstrate that nanoDot™ can be potentially used for in-vivo dosimetry verification in various clinical situations, with a high degree of accuracy and precision. In addition OSLDs exhibit better dose reproducibility with standard deviation of 1.8%. There was no significant difference in their response to 6 and 18MV beams. The dose response was also linear.

60 APPLIED LIFE SCIENCES↗

TH-AB-201-07: Filmless Treatment Localization QA for the CyberKnife System

Purpose: Accuray recommends daily evaluation of the treatment localization and delivery systems (TLS/TDS) of the CyberKnife. The vendor-provided solution is a Winston-Lutz-type test that evaluates film shadows from an orthogonal beam pair (known as AQA). Since film-based techniques are inherently inefficient and potentially inconsistent and uncertain, this study explores a method which provides a comparable test with greater efficiency, consistency, and certainty. This test uses the QAStereoChecker (QASC, Standard Imaging, Inc., Middleton, WI), a high-resolution flat-panel detector with coupled fiducial markers for automated alignment. Fiducial tracking is used to achieve high translational and rotational position accuracy. Methods: A plan is generated delivering five circular beams, with varying orientation and angular incidence. Several numeric quantities are calculated for each beam: eccentricity, centroid location, area, major-axis length, minor-axis length, and orientation angle. Baseline values were acquired and repeatability of baselines analyzed. Next, errors were induced in the path calibration of the CK, and the test repeated. A correlative study was performed between the induced errors and quantities measured using the QASC. Based on vendor recommendations, this test should be able to detect a TLS/TDS offset of 0.5mm. Results: Centroid shifts correlated well with induced plane-perpendicular offsets (p < 0.01). Induced vertical shifts correlated best with the absolute average deviation of eccentricities (p < 0.05). The values of these metrics which correlated with the threshold of 0.5mm induced deviation were used as individual pass/fail criteria. These were then used to evaluate induced offsets which shifted the CK in all axes (a clinically-realistic offset), with a total offset of 0.5mm. This test provided high and specificity and sensitivity. Conclusion: From setup to analysis, this filmless TLS/TDS test requires 4 minutes, as opposed to 15–20 minutes for film-based methods. The techniques introduced can potentially isolate errors in individual joints of the CK robot. Spectrum Medical Physics, LLC of Greenville, SC has a consulting contract with Standard Imaging of Middleton, WI.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neuroevolution Application to Collaborative and Heuristics-Based Connected and Autonomous Vehicle Cohort Simulation at Uncontrolled Intersection

Artificial intelligence is gaining tremendous attractiveness and showing great success in solving various problems, such as simplifying optimal control derivation. This work focuses on the application of Neuroevolution to the control of Connected and Autonomous Vehicle (CAV) cohorts operating at uncontrolled intersections. The proposed method implementation’s simplicity, thanks to the inclusion of heuristics and effective real-time performance are demonstrated. The resulting architecture achieves nearly ideal operating conditions in keeping the average speeds close to the speed limit. It achieves twice as high mean speed throughput as a controlled intersection, hence enabling lower travel time and mitigating energy inefficiencies from stop-and-go vehicle dynamics. Low deviation from the road speed limit is hence continuously sustained for cohorts of at most 50 m long. This limitation can be mitigated with additional lanes that the cohorts can split into. The concept also allows the testing and implementation of fast-turning lanes by simply replicating and reconnecting the control architecture at each new road crossing, enabling high scalability for complex road network analysis. The controller is also successfully validated within a high-fidelity vehicle dynamic environment, showing its potential for driverless vehicle control in addition to offering a new traffic control simulation model for future autonomous operation studies.

Jacquelin, Frederic (ORCID:0000000183154344)↗

Land Surface Temperature Measurements form EOS MODIS Data

We have developed a physics-based land-surface temperature (LST) algorithm for simultaneously retrieving surface band-averaged emissivities and temperatures from day/night pairs of MODIS (Moderate Resolution Imaging Spectroradiometer) data in seven thermal infrared bands. The set of 14 nonlinear equations in the algorithm is solved with the statistical regression method and the least-squares fit method. This new LST algorithm was tested with simulated MODIS data for 80 sets of band-averaged emissivities calculated from published spectral data of terrestrial materials in wide ranges of atmospheric and surface temperature conditions. Comprehensive sensitivity and error analysis has been made to evaluate the performance of the new LST algorithm and its dependence on variations in surface emissivity and temperature, upon atmospheric conditions, as well as the noise-equivalent temperature difference (NE(Delta)T) and calibration accuracy specifications of the MODIS instrument. In cases with a systematic calibration error of 0.5%, the standard deviations of errors in retrieved surface daytime and nighttime temperatures fall between 0.4-0.5 K over a wide range of surface temperatures for mid-latitude summer conditions. The standard deviations of errors in retrieved emissivities in bands 31 and 32 (in the 10-12.5 micrometer IR spectral window region) are 0.009, and the maximum error in retrieved LST values falls between 2-3 K. Several issues related to the day/night LST algorithm (uncertainties in the day/night registration and in surface emissivity changes caused by dew occurrence, and the cloud cover) have been investigated. The LST algorithms have been validated with MODIS Airborne Simulator (MAS) dada and ground-based measurement data in two field campaigns conducted in Railroad Valley playa, NV in 1995 and 1996. The MODIS LST version 1 software has been delivered.

Wan, Zhengming↗

Performance of quantum Monte Carlo for calculating molecular bond lengths

This work investigates the accuracy of real-space quantum Monte Carlo (QMC) methods for calculating molecular geometries. We present the equilibrium bond lengths of a test set of 30 diatomic molecules calculated using variational Monte Carlo (VMC) and diffusion Monte Carlo (DMC) methods. The effect of different trial wavefunctions is investigated using single determinants constructed from Hartree-Fock (HF) and Density Functional Theory (DFT) orbitals with LDA, PBE, and B3LYP functionals, as well as small multi-configurational self-consistent field (MCSCF) multi-determinant expansions. When compared to experimental geometries, all DMC methods exhibit smaller mean-absolute deviations (MADs) than those given by HF, DFT, and MCSCF. The most accurate MAD of 3 ± 2 × 10{sup −3} Å is achieved using DMC with a small multi-determinant expansion. However, the more computationally efficient multi-determinant VMC method has a similar MAD of only 4.0 ± 0.9 × 10{sup −3} Å, suggesting that QMC forces calculated from the relatively simple VMC algorithm may often be sufficient for accurate molecular geometries.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Nonylphenol in pregnant women and their matching fetuses: Placental transfer and potential risks of infants

As the predominant environmental biodegradation product of nonylphenol (NP) ethoxylates and with proven estrogenic effects, NP is formed during the alkylation process of phenols. The purposes of this study were (1) to examine maternal and prenatal exposure to NP in Taiwan, (2) to determine the level of placental protection against NP exposure as well as the level of NP in breast milk, and (3) to assess the potential risk for breastfed newborns exposed to NP through the milk. Thirty pairs of maternal and fetal blood samples, placenta, and breast milk during the 1st and the 3rd months of lactation were collected. External NP exposures of these specimens were then analyzed by using high-performance liquid chromatography coupling with fluorescence detection. Next, the socio-demographics, lifestyle, delivery method, dietary and work history were collected using a questionnaire. In addition, the daily intake of NP from consuming breast milk in the 1st and 3rd months for newborns was studied through deterministic and probabilistic risk assessment methods. The geometric means and geometric standard deviation of NP levels in maternal blood, fetal cord blood, placenta, and breast milk in the 1st and 3rd months were 14.6 (1.7) ng/ml, 18.8 (1.8) ng/ml, 19.8 (1.9) ng/g, 23.5 (3.2) ng/ml, and 57.3 (1.4) ng/ml, respectively. The probabilistic percentiles (50th, 75th, and 95th) of daily intake NP in breast milk were 4.33, 7.79, and 18.39 μg/kg-bw/day in the 1st month, respectively, and were 8.11, 10.78, 16.08 μg/kg-bw/day in the 3rd month, respectively. The probabilistic distributions (5th, 25th, and 50th) of risk for infants aged 1 month old were 0.27, 0.64, and 1.15, respectively, and that for infants aged 3 month old were 0.31, 0.46, and 0.62, respectively. Through repeated exposure from the dietary intake of expectant mothers, fetuses could encounter a high NP exposure level due to transplacental absorption, partitioning between the maternal and fetal compartments. Daily NP intake via breast milk in three month-old babies exceeded the tolerable daily intake (TDI) of 5 µg/kg bw/day indicated a potential risk for Taiwan infants. - Highlights: • A cohort of pregnant women was established and followed until delivery. • The pregnant and lactating mothers and their infants were exposed to NP. • Fetuses in Taiwan showed high NP milk level. • Daily NP intake via breast milk indicated a potential risk for Taiwan infants.

60 APPLIED LIFE SCIENCES↗

Modeling and Experimental Validation of a Direct-Contact Counter-Flow Fluidized Bed Heat Exchanger for Thermal Energy Storage (TES) Applications

Particle-based thermal energy storage (TES) systems are an emerging energy storage technology. The technological advances have reduced costs, making TES more competitive and reliable in the marketplace but an efficient and reliable operation is heavily dependent on coherent heat transfer between air to particles or vice versa. The particle-based TES technologies provide an intermediate system that can store energy for short (0-10 h), long (10-200 h) and seasonal (> 200 h) timescales. The TES systems store energy by converting electricity to thermal energy; electricity can be directly sourced intermittent generation technologies and/or the grid, helping manage peak loads and other mismatches in supply and demand. The overall efficiency of the TES system depends on the performance of system components (particle storage silos and particle transfer mechanism etc.). The particle heat exchanger is one of the key system components that affects the system efficiency. The pressurized fluidized bed heat exchanger (PFB HX) performance is challenging to predict due to the chaotic behavior of particle and fluid interaction. This research presents a computational study of a novel direct-contact, counter-flow and air-to-particles PFB HX, that contributes in advancing the particle-based long-duration TES technologies. For the current analysis an unsteady Eulerian-Eulerian CFD model was developed and validated against experiments performed at the National Laboratory of the Rockies for two particle sizes (600 ..mu..m and 825 ..mu..m ). Following validation, parametric simulations were conducted to evaluate the effects of interphase drag models (Syamlal-O'Brien and Gidaspow), particle size, bed height and the influence of a frictional-viscosity term on hydrodynamics and heat transfer between the air & particles. The key findings from the analysis are: (1) for the studied operating window Syamlal-O'Brien provides superior agreement with measured gas temperatures (errors generally < 10%) while Gidaspow shows large deviations for the coarse particle case; (2) model predictions are most sensitive in the lower 0.2 m above the air distributor where bubble initiation and local mixing dominate interphase heat transfer; (3) representation of the distributor (number of inlet ports) materially affects predicted local mixing and temperature stratification; and (4) the Eulerian-Eulerian framework reproduces bulk thermal trends but shows regime dependent limitations for coarse particles, motivating mesoscale informed closures for scale-up analysis for future studies. These results provide validated guidance for drag selection and distributor design in particle-based thermal energy storage applications. Collectively, the validated model and parametric results quantify key drivers of PHB-HX performance and provide practical guidance for design and optimization. The results provide confidence in the model predictability and provide a step forward to improve on heat exchange performance. The demonstrated performance and modeling approach support the deployment and further development of this novel PHB-HX concept for robust, particle-based long-duration thermal energy storage systems.

25 ENERGY STORAGE↗

Towards an Enhanced Droplet Activation Scheme for Multi-Moment Bulk Microphysics Schemes

Initial droplet spectra produced upon activation impact the ensuing chain of microphysical processes andtherefore play a crucial role in cloud evolution. This work re-examines dependencies of newly formed clouddroplet size distribution (CDSD) characteristics on environmental and aerosol properties via parcel model simulationsthat serve as the basis for a multi-moment bulk microphysics droplet activation scheme suitable for acloud-resolving model (CRM). It is found that applying a fixed size threshold to define activated droplets versusemploying physical considerations can lead to erroneous activation and overly broad CDSDs for high aerosolconcentration and weak updraft conditions. Aerosol distributions characterized by larger median sizes and/orincreased solubility can result in greater activated droplet numbers, whereas impacts of these parameters onCDSD spectral width depend on both aerosol number concentration and updraft velocity. An expansion of theactivation scheme to include CDSD spectral width is proposed to aid efforts to extend high-order momentprediction to cloud droplet categories in CRMs as well as better represent variability in the activation process onthe cloud scale.simulations to investigate the regime dependence of the relative dispersion(d)1 of newly activated CDSDs, where d is the ratio of dropletradius standard deviation (σ) to the mean radius (r ). C16 demonstratedthat increasing Na resulted in increasing (decreasing) d values via reducedcondensational narrowing (spectral broadening) rates within theAL (UL) regime, with d values peaking in the TR regime. Their findingssuggest a similar regime dependence for d as R09 noted for Nc and helpexplain reportedly conflicting relationships between Na and CDSDspectral characteristics (cf. Hudson and Noble, 2014; Liu et al., 2014),although the applicability of these results within bulk microphysicalschemes was not addressed.Simulating aerosol-cloud interactions with CRMs employing bulkmicrophysics requires that the scheme minimally predict two CDSDparameters, namely mass and number concentrations, and represent thedroplet activation process. Various activation schemes aim to determineNc from aerosol and environmental properties and include analyticalexpressions (e.g., Abdul-Razzak et al., 1998; Morrison et al., 2005) aswell as lookup tables (LUTs) based on detailed parcel model calculations(e.g., Saleeby and Cotton, 2004, hereafter SC04; Segal and Khain,2006; Thompson and Eidhammer, 2014). Expressions to diagnose CDSDspectral width from Nc (Grabowski, 1998; Liu et al., 2006; Morrison andGrabowski, 2007) or cloud water content (Geoffroy et al., 2010) havealso been developed, although more robust methods to obtain CDSDspectral width upon activation are presently lacking. This latter point isrelevant for triple-moment (3 M) bulk microphysics that aim to predictdistribution spectral width alongside number and mass concentrations(e.g., Loftus et al., 2014; Milbrandt and Yau, 2005).The current work extends the findings of C16 to the current LUTbasedaerosol activation scheme used in the Regional AtmosphericModeling System (RAMS) (Cotton et al., 2003; SC04; Saleeby and vanden Heever, 2013, hereafter SvdH13) and additionally examinesaerosol size and solubility impacts on newly activated CDSD properties.Because early cloud development processes such as condensationalgrowth, evaporation, and droplet self-collection depend on and impactCDSD spectral width (Hudson and Yum, 1997; Seifert and Beheng 2001;Lu and Seinfeld, 2006; Igel and van den Heever, 2017), an expansion ofthe activation LUTs to include CDSD spectral width is proposed as apreliminary step for extending 3M prediction to CDSDs in CRMs forimproved simulations of aerosol-cloud interactions.2. MethodologyThe current RAMS two-moment microphysics module determinesthe fractional number of aerosol particles that activate to cloud dropletsfrom five-dimensional LUTs based on model predicted air temperature(T), w, Na, and the geometric median radius (rg) and soluble fraction (ε)of the aerosol size distribution (SvdH13). These LUTs are created offlineusing a one-dimensional Lagrangian adiabatic parcel model (Feingoldand Heymsfield, 1992; Heymsfield and Sabin, 1989; SC04) to simulateexplicit droplet activation and initial CDSD growth for a range of ambientatmospheric conditions [T, w] and binned lognormal aerosol sizedistributions given by= ⎡⎣ ⎢− ⎤⎦ ⎥N r Nr π σr rσ( )2 lnexp[ln( / )]2(ln )aggg22 (1)where r is the dry aerosol particle bin radius and σg is the geometricstandard deviation of the distribution. As the parcel model simulationsfocus on the activation process, other processes such as coalescence,sedimentation, and mixing are not considered. Details of the parcelmodel can be found in SC04 and SvdH13, and only a brief description isprovided here. At the onset of parcel model calculations, the initiallydry aerosol particles in all bins first deliquesce and reach theirequilibrium diameters in a sub-saturated environment based on theKöhler equation for solution droplets. The parcel is then lifted at a fixedupward velocity w, and particle growth by vapor diffusion, along withconcurrent changes in the ambient environment, are iteratively computedusing the Variable-coefficient Ordinary Differential Equation(VODE) solver (Brown et al., 1989). The time resolution of these calculationsis determined within the VODE solver, and the frequency atwhich the solver is called is controlled by a longer model time stepbased on fixed upward parcel displacement increments (Δz) at thespecified w (Δt=Δz/w). Model calculations proceed until the parcelreaches a height 50m beyond the level of maximum saturation ratio(Smax) or total parcel displacement exceeds 2 km. Upon model termination,Smax and the fractional number of aerosols (factv) resulting innewly formed cloud droplets, defined as particles having diameters of atleast 2 μm, are cataloged in the LUTs according to the specified T, w, Na,rg, and ε parameter values.A critical point regarding the creation of these LUTs is the use of afixed minimum diameter (Dmin) to define cloud droplets in the parcelmodel, which can produce erroneous CDSD characteristics, particularlywithin the UL regime. For aerosol distributions with large rg valuesunder low SS conditions, for example, deliquesced aerosols within thelarge tail of the distribution can exceed 2 μm in diameter yet remainunactivated as ‘haze’ particles (Levin and Cotton, 2009; McFigganset al., 2006). For this study, aerosol particles activate to cloud dropletsbased on the critical diameter Dcrit as a function of parcel supersaturationratio (Sr) as in R09:D = σ MS RTρ83 ln( ) critsol wr w (2)where σsol is the surface tension of a solution droplet, Mw and ρw are themolar mass and density of liquid water, respectively, and R is theuniversal gas constant. Additionally, at relatively large w values withinthe AL regime, Nc stabilizes shortly after reaching supersaturation.However, parcel ascent and condensational growth continue beyondthe level of Smax, potentially causing additional narrowing of the CDSD.In the current work, model calculations terminate upon reaching Smaxas changes in Nc are negligible with continued ascent (Peng et al., 2007;R09).Parcel model simulations are performed to examine the sensitivitiesof CDSD characteristics to w, Na, rg, and ε, with the ranges for theseparameters listed in Table 1. Aerosols are assumed to be a mix of solubleand insoluble material of equal density, specified by ε, where fullysoluble aerosols correspond to ammonium sulfate with hygroscopicityparameter κ=0.61 (Petters and Kreidenweis, 2007). FollowingSvdH13, aerosol geometric standard deviation is fixed at σg=1.8, andaerosol distributions (Eq. 1) are partitioned into 100 logarithmicallyspacedbins spanning a size range specific to each rg value. For all simulations,Δz=1 m, and initial values of relative humidity, air temperatureand pressure are set to RH=0.99, T=10 °C and p=900 hPa,respectively.

Loftus, Adrian M.↗