Search NASA⌕ Search

SEARCH · Search NASA

Results for “Positioning Resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,765 records · Page 98

A search for the H2 /3, 0/ S1 line in the spectrum of Titan

Results are reported for measurements of the quadrupole S1 line of the (3, 0) absorption band of H2 in spectra of Titan, which were performed at an effective resolution of 0.09 A by scanning with a PEPSIOS spectrometer over a range of 0.85 A centered at the expected position of the investigated line and sampling in 80 contiguous channels. No statistically significant H2 (3, 0) S1 feature is found in the spectra, but a three-sigma upper limit of 3 mA is set for the equivalent width of the S1 line that might be present in a co-added spectrum. It is concluded that these measurements do not provide any evidence for the presence of H2 in the atmosphere of Titan.

Muench, G.↗

Crossed grid anode and its image partitioning

Measurements on an imaging crossed grid anode following a pair of microchannel plates indicate fast charge propagation via wire-to-wire capacitances, suggesting a temporal resolution of 100 ns. A figure of merit for partitioned systems has been suggested that provides an estimate of the position uncertainty of photoelectrons in the image plane of an anode. Solutions for two-, three-, and four-amplifier position algorithms are given, and basic system requirements are discussed.

Knapp, G.↗

Quadrispherical LEPEDEAS for ISEE's-1 and -2 plasma measurements

A new generation of spaceflight instrumentation for comprehensive measurements of plasmas within the earth's magnetosphere and its environs is described. These quadrispherical low energy proton and electron differential energy analyzers (LEPEDEAS) for the ISEE's-1 and -2 spacecraft are capable of determining the directional intensities of positive ions and electrons over all but 2 percent of the 4 pi sr solid angle for charged-particle velocity vectors at the spacecraft positions. The energy range of this instrumentation is E/Q of 1 eV to 45 keV with good energy and angular resolutions. An example of inflight observations within the earth's magnetosheath is presented.

Frank, L. A.↗

Infrared methane spectra between 1120 per cm and 1800 per cm - A new atlas

A new atlas of CH4 lines in the 1120-1800-per cm region has been generated, based on laboratory spectra taken with a Nicolet interferometer at 0.06-per cm resolution with 635-cm path length at pressures of 0.98 torr, 4.86 torr, and 19.97 torr. A compilation of line positions and line intensities includes 1339 CH4 lines, several hundred of which have not been previously observed.

Blatherwick, R. D.↗

Two-dimensional inversion technique for satellite airglow data

A technique is described which inverts satellite airglow data producing volume emission rates as functions of altitude and position. The inversion is applied to data obtained when the spacecraft spins in the orbital plane. The altitude and height resolutions are constrained by the geometry chosen to simplify the inversion. The limitations of the method and its implementation on data from the Visual Airglow Experiment onboard the Atmosphere Explorer satellite are discussed. Sample maps of brightness and volume emission rates are shown.

Fesen, C. G.↗

Dark streaks on talus slopes, Mars

High-resolution pictures of talus slopes on Mars show small, dark streaks that characteristically widen downward. These streaks are different from the thin and even streaks of various albedos that stream from cliffs on talus slopes, but gradations between the two streak types occur and not all streaks can be classified with confidence. In order to study the nature and origin of the small, widening, dark streaks, all Viking pictures with a resolution of less than 100 m/pixel were surveyed. To date several hundred streaks were located, but only few are of high enough resolution to be confidently identified as widening downwards. The approximate dimensions of the streaks were measured and their shapes, numbers, position, and spacing on slopes were noted. They were plotted on a topographic map, and their relation to topography, geologic units, and regions of distinct thermal inertia and albedo were studied. Also noted was the season at which images containing streaks were acquired and the direction of illumination. Albedo measurements are in progress. Several streaks can be seen stereoscopically, but none are observed on color images. The observation of small dark streaks on talus slopes on Mars is compatible with an interpretation of their origin as eruptions of small masses of wet debris in places where steep walls intersect aquifers or where seasonal equatorial warming permits the local melting of ground ice.

Ferguson, H. M.↗

Measurements of thermospheric response to auroral activities

The Joule heating produced by auroral electrojets and its thermospheric response can be studied by monitoring the thermospheric temperatures by optical methods; simultaneously, the concurrent auroral electrojet activities can be investigated by using geomagnetic records obtained from stations along a meridian close to the observation site of optical measurements. The measurements are reported of thermospheric response to auroral activities which were made at Albany (42.68 deg N, 73.82 deg W), New York on September 2, 1978 (UT) when an isolated substorm occured. The thermospheric temperatures were measured by using a high resolution Fabry-Perot interferometer that determines the line profiles of the (OI) 6300A line emission. The intensities and latitudinal positions of auroral electrojets were obtained by the analysis of magnetograms from the IMS Fort Churchill meridian chain stations.

Okano, S.↗

Subminiature Hot-Wire Probes

Class of improved subminiature hot-wire flow-measuring probes developed. Smaller sizes yield improved resolution in measurements of practical aerodynamic flows. Probe made in one-wire, two-perpendicular-wire, and three-perpendicular-wire version for measurement of one, two, or all three components of flow. Oriented and positioned on micromanipulator stage and viewed under microscope during fabrication. Tested by taking measurements in constant-pressure turbulent boundary layer. New probes give improved measurements of turbulence quantities near surfaces and anisotropies of flows strongly influence relative errors caused by phenomena related to spatial resolution.

Westphal, R. V.↗

Application of a two-stream radiative transfer model for leaf lignin and cellulose concentrations from spectral reflectance measurements, part 2

We used the Kubelka-Munk theory of diffuse spectral reflectance in layers to analyze influences of multiple chemical components in leaves. As opposed to empirical approaches to estimation of plant chemistry, the full spectral resolution of laboratory reflectance data was retained in an attempt to estimate lignin or other constituent concentrations from spectral band positions. A leaf water reflectance spectrum was derived from theoretical mixing rules, reflectance observations, and calculations from theory of intrinsic k- and s-functions. Residual reflectance bands were then isolated from spectra of fresh green leaves. These proved hard to interpret for composition in terms of simple two component mixtures such as lignin and cellulose. We next investigated spectral and dilution influences of other possible components (starch, protein). These components, among others, added to cellulose in hypothetical mixtures, produce band displacements similar to lignin, but will disguise by dilution the actual abundance of lignin present in a multicomponent system. This renders interpretation of band positions problematical. Knowledge of end-members and their spectra, and a more elaborate mixture analysis procedure may be called for. Good observational atmospheric and instrumental conditions and knowledge thereof are required for retrieval of expected subtle reflectance variations present in spectra of green vegetation.

Conel, James E.↗

Flexcam Image Capture Viewing and Spot Tracking

Flexcam software was designed to allow continuous monitoring of the mechanical deformation of the telescope structure at Palomar Observatory. Flexcam allows the user to watch the motion of a star with a low-cost astronomical camera, to measure the motion of the star on the image plane, and to feed this data back into the telescope s control system. This automatic interaction between the camera and a user interface facilitates integration and testing. Flexcam is a CCD image capture and analysis tool for the ST-402 camera from Santa Barbara Instruments Group (SBIG). This program will automatically take a dark exposure and then continuously display corrected images. The image size, bit depth, magnification, exposure time, resolution, and filter are always displayed on the title bar. Flexcam locates the brightest pixel and then computes the centroid position of the pixels falling in a box around that pixel. This tool continuously writes the centroid position to a network file that can be used by other instruments.

Rao, Shanti↗

The General Antiparticle Spectrometer (GAPS) Antarctic Balloon Payload

The General Antiparticle Spectrometer (GAPS) is an Antarctic stratospheric balloon mission designed to provide unmatched sensitivity to low-energy (<0.25 GeV/n) cosmic-ray antiprotons, antideuterons, and antihelium nuclei as signatures of dark matter. The distinctive GAPS particle identification technique relies on measuring the energy loss along the track of an incoming antinucleus as it slows down and is captured into an exotic atom, and then detecting the de-excitation X-rays and the nuclear annihilation products. This measurement is realized using a Tracker composed of more than 1000 custom silicon strip detectors and a plastic scintillator time-of-flight (TOF) system instrumenting more than 40m$^2$. Together, these subsystems provide the velocity and energy resolution, stopping power, particle tracking, and X-ray identification necessary to distinguish rare antinucleus signals from the abundant positive-nucleus backgrounds, all within the constraints of a high-altitude mission. A multi-loop capillary heat pipe system has been developed to maintain the tracker operating temperature with significant mass and power savings over a conventional pump-based system. The first GAPS science payload flew for 25 days during the 2025/26 NASA Antarctic balloon campaign. We detail the design, integration, and commissioning of the payload prior to flight.

Aoyama, Kazutaka [JAXA, Sagamihara]↗

WEAK GRAVITATIONAL LENSING AS A PROBE OF PHYSICAL PROPERTIES OF SUBSTRUCTURES IN DARK MATTER HALOS

We propose a novel method to select satellite galaxies in outer regions of galaxy groups or clusters using weak gravitational lensing. The method is based on the theoretical expectation that the tangential shear pattern around satellite galaxies would appear with negative values at an offset distance from the center of the main halo. We can thus locate the satellite galaxies statistically with an offset distance of several lensing smoothing scales by using the standard reconstruction of surface mass density maps from weak lensing observation. We test the idea using high-resolution cosmological simulations. We show that subhalos separated from the center of the host halo are successfully located even without assuming the position of the center. For a number of such subhalos, the characteristic mass and offset length can be also estimated on a statistical basis. We perform a Fisher analysis to show how well upcoming weak lensing surveys can constrain the mass density profile of satellite galaxies. In the case of the Large Synoptic Survey Telescope with a sky coverage of 20,000 deg{sup 2}, the mass of the member galaxies in the outer region of galaxy clusters can be constrained with an accuracy of ∼0.1 dex for galaxy clusters with mass 10{sup 14} h {sup –1} M {sub ☉} at z = 0.15. Finally we explore the detectability of tidal stripping features for subhalos having a wide range of masses of 10{sup 11}-10{sup 13} h {sup –1} M {sub ☉}.

79 ASTRONOMY AND ASTROPHYSICS↗

Optimizing the spatial resolution and gamma discrimination of SiPM-based Anger cameras

SiPM Anger cameras have been designed for use as 2-dimensional thermal neutron detectors for scientific applications such as at single crystal diffraction instruments. These cameras utilize a neutron sensitive scintillator and an array of SiPM photosensors, separated by a light spreading glass. While this optics package is very effective at detecting and positioning neutrons, it is also sensitive to gamma rays, which are a source of unwanted noise. In this work, we underwent a search of scintillator and spreader glass thicknesses to determine the optimal combination for maximizing spatial resolution. Both experimental results and GEANT4 simulations are presented. Further, to address the issue of gamma ray detection, we have also designed and presented a multi-layer scintillator that reduces the amount of scintillation light produced via gamma-ray energy deposition, allowing for easier pulse-height discrimination. A sample of this geometry has been produced that results in a factor of 2 improvement over an equivalent thickness monolithic scintillator.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-C-201-03: Coded Aperture Gamma-Ray Imaging Using Pixelated Semiconductor Detectors

Purpose: Improved localization of gamma-ray emissions from radiotracers is essential to the progress of nuclear medicine. Polaris is a portable, room-temperature operated gamma-ray imaging spectrometer composed of two 3×3 arrays of thick CdZnTe (CZT) detectors, which detect gammas between 30keV and 3MeV with energy resolution of <1% FWHM at 662keV. Compton imaging is used to map out source distributions in 4-pi space; however, is only effective above 300keV where Compton scatter is dominant. This work extends imaging to photoelectric energies (<300keV) using coded aperture imaging (CAI), which is essential for localization of Tc-99m (140keV). Methods: CAI, similar to the pinhole camera, relies on an attenuating mask, with open/closed elements, placed between the source and position-sensitive detectors. Partial attenuation of the source results in a “shadow” or count distribution that closely matches a portion of the mask pattern. Ideally, each source direction corresponds to a unique count distribution. Using backprojection reconstruction, the source direction is determined within the field of view. The knowledge of 3D position of interaction results in improved image quality. Results: Using a single array of detectors, a coded aperture mask, and multiple Co-57 (122keV) point sources, image reconstruction is performed in real-time, on an event-by-event basis, resulting in images with an angular resolution of ∼6 degrees. Although material nonuniformities contribute to image degradation, the superposition of images from individual detectors results in improved SNR. CAI was integrated with Compton imaging for a seamless transition between energy regimes. Conclusion: For the first time, CAI has been applied to thick, 3D position sensitive CZT detectors. Real-time, combined CAI and Compton imaging is performed using two 3×3 detector arrays, resulting in a source distribution in space. This system has been commercialized by H3D, Inc. and is being acquired for various applications worldwide, including proton therapy imaging R&D.

60 APPLIED LIFE SCIENCES↗

A comparison of water vapor derived from GPS occultations and global weather analyses

Occultation measurements from the Global Positioning System (GPS) should improve upon this situation. Individual occultations yield profiles of specific humidity accurate to 0.2 to 0.5 g/kg providing sensitive measurements of lower and middle tropospheric water vapor with global coverage in a unique, all-weather, limb-viewing geometry with several hundred metres to a kilometre vertical resolution. The authors have derived water vapor profiles from June 21 to July 4, 1995

global↗

Towards the spatial resolution of metalloprotein charge states by detailed modeling of XFEL crystallographic diffraction

Oxidation states of individual metal atoms within a metalloprotein can be assigned by examining X-ray absorption edges, which shift to higher energy for progressively more positive valence numbers. Indeed, X-ray crystallography is well suited for such a measurement, owing to its ability to spatially resolve the scattering contributions of individual metal atoms that have distinct electronic environments contributing to protein function. However, as the magnitude of the shift is quite small, about +2 eV per valence state for iron, it has only been possible to measure the effect when performed with monochromated X-ray sources at synchrotron facilities with energy resolutions in the range 2–3 × 10 −4 (Δ E / E ). This paper tests whether X-ray free-electron laser (XFEL) pulses, which have a broader bandpass (Δ E / E = 3 × 10 −3 ) when used without a monochromator, might also be useful for such studies. The program nanoBragg is used to simulate serial femtosecond crystallography (SFX) diffraction images with sufficient granularity to model the XFEL spectrum, the crystal mosaicity and the wavelength-dependent anomalous scattering factors contributed by two differently charged iron centers in the 110-amino-acid protein, ferredoxin. Bayesian methods are then used to deduce, from the simulated data, the most likely X-ray absorption curves for each metal atom in the protein, which agree well with the curves chosen for the simulation. The data analysis relies critically on the ability to measure the incident spectrum for each pulse, and also on the nanoBragg simulator to predict the size, shape and intensity profile of Bragg spots based on an underlying physical model that includes the absorption curves, which are then modified to produce the best agreement with the simulated data. This inference methodology potentially enables the use of SFX diffraction for the study of metalloenzyme mechanisms and, in general, offers a more detailed approach to Bragg spot data reduction.

59 BASIC BIOLOGICAL SCIENCES↗