Search NASA⌕ Search

SEARCH · Search NASA

Results for “Positioning System”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,765 records · Page 98

A spatial beam property analyzer based on dispersive crystal diffraction for low-emittance X-ray light sources

Abstract The advent of low-emittance synchrotron X-ray sources and free-electron lasers urges the development of novel diagnostic techniques for measuring and monitoring the spatial source properties, especially the source sizes. This work introduces an X-ray beam property analyzer based on a multi-crystal diffraction geometry, including a crystal-based monochromator and a Laue crystal in a dispersive setting to the monochromator. By measuring the flat beam and the transmitted beam profiles, the system can provide a simultaneous high-sensitivity characterization of the source size, divergence, position, and angle in the diffraction plane of the multi-crystal system. Detailed theoretical modeling predicts the system’s feasibility as a versatile characterization tool for monitoring the X-ray source and beam properties. The experimental validation was conducted at a bending magnet beamline at the Swiss Light Source by varying the machine parameters. A measurement sensitivity of less than 10% of a source size of around 12 µm is demonstrated. The proposed system offers a compact setup with simple X-ray optics and can also be utilized for monitoring the electron source.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Target and orbit feedback simulations of a muSR beam line at BNL

Well-polarized positive surface muons are a tool to measure the magnetic properties of materials since the precession rate of the spin can be determined from the observation of the positron directions when the muons decay. For a dc beam an ideal µSR flux for surface µ + should be about 40 kHz/mm 2 . In this report we show how this flux could be achieved in a beam line using the AGS complex at BNL for a source of protons. We also determined that an orbit feedback system with a pair of thin silicon position monitors and kickers would miss the desired flux by at least an order of magnitude, even with perfect time resolution and no multiple scattering.

43 PARTICLE ACCELERATORS↗

Relative importance between biogeochemical and biogeophysical effects in regulating terrestrial ecosystem-climate feedback in northern high latitudes

Warming-induced changes in structures and functions of northern terrestrial ecosystems (NTEs), including their regulation on terrestrial biogeochemistry and surface energy balance, may exert positive or negative feedback to the climate system. However, the relative importance among these biogeochemical and biogeophysical feedback is not well understood. Here we use a terrestrial ecosystem model to quantify spatially explicit ecosystem-climate feedback over NTEs (north of 50°N) under four climate change scenarios from 2010 to 2100, including biogeochemical feedback from climate-induced changes in net CH4 exchanges (NME) and net CO 2 exchanges (NCE) and biogeophysical feedback from changes in surface energy partitioning associated with snow cover and vegetation biomass dynamics. Our results indicate that (1) biogeochemical and biogeophysical feedback are attributed more to the changes in NME and snow cover dynamics, respectively; (2) net biogeophysical feedback is much larger than net biogeochemical feedback; (3) NTEs will cause a net positive radiative forcing of 0.04–0.26 Wm -2 between 2010 and 2100. Our findings support the notion that NTEs will exert positive net climate feedback; however, our estimation of positive net biogeochemical feedback including NME- and NCE-induced effects is contrary to previous studies showing negative net biogeochemical feedback including NCE-induced effect only. In conclusion, this study highlights the importance of NME-induced biogeochemical effect in regulating ecosystem-climate feedback in NTEs and implies that previous studies without considering NME-induced effect might have underestimated the intensity of total terrestrial feedback to the climate system.

54 ENVIRONMENTAL SCIENCES↗

Stereo-Optic High Definition Imaging: A New Technology to Understand Bird and Bat Avoidance of Wind Turbines

There is a critical need to develop monitoring tools to track aerofauna (birds and bats) in three dimensions around wind turbines. New monitoring systems will reduce permitting uncertainty by increasing the understanding of how birds and bats are interacting with wind turbines, which will improve the accuracy of impact predictions. Biodiversity Research Institute (BRI), The University of Maine Orono School of Computing and Information Science (UMaine SCIS), HiDef Aerial Surveying Limited (HiDef), and SunEdison, Inc. (formerly First Wind) responded to this need by using stereo-optic cameras with near-infrared (nIR) technology to investigate new methods for documenting aerofauna behavior around wind turbines. The stereo-optic camera system used two synchronized high-definition video cameras with fisheye lenses and processing software that detected moving objects, which could be identified in post-processing. The stereo- optic imaging system offered the ability to extract 3-D position information from pairs of images captured from different viewpoints. Fisheye lenses allowed for a greater field of view, but required more complex image rectification to contend with fisheye distortion. The ability to obtain 3-D positions provided crucial data on the trajectory (speed and direction) of a target, which, when the technology is fully developed, will provide data on how animals are responding to and interacting with wind turbines. This project was focused on testing the performance of the camera system, improving video review processing time, advancing the 3-D tracking technology, and moving the system from Technology Readiness Level 4 to 5. To achieve these objectives, we determined the size and distance at which aerofauna (particularly eagles) could be detected and identified, created efficient data management systems, improved the video post-processing viewer, and attempted refinement of 3-D modeling with respect to fisheye lenses. The 29-megapixel camera system successfully captured 16,173 five-minute video segments in the field. During nighttime field trials using nIR, we found that bat-sized objects could not be detected more than 60 m from the camera system. This led to a decision to focus research efforts exclusively on daytime monitoring and to redirect resources towards improving the video post- processing viewer. We redesigned the bird event post-processing viewer, which substantially decreased the review time necessary to detect and identify flying objects. During daytime field trials, we determine that eagles could be detected up to 500 m away using the fisheye wide-angle lenses, and eagle-sized targets could be identified to species within 350 m of the camera system. We used distance sampling survey methods to describe the probability of detecting and identifying eagles and other aerofauna as a function of distance from the system. The previously developed 3-D algorithm for object isolation and tracking was tested, but the image rectification (flattening) required to obtain accurate distance measurements with fish-eye lenses was determined to be insufficient for distant eagles. We used MATLAB and OpenCV to improve fisheye lens rectification towards the center of the image, but accurate measurements towards the image corners could not be achieved. We believe that changing the fisheye lens to rectilinear lens would greatly improve position estimation, but doing so would result in a decrease in viewing angle and depth of field. Finally, we generated simplified shape profiles of birds to look for similarities between unknown animals and known species. With further development, this method could provide a mechanism for filtering large numbers of shapes to reduce data storage and processing. These advancements further refined the camera system and brought this new technology closer to market. Once commercialized, the stereo-optic camera system technology could be used to: a) research how different species interact with wind turbines in order to refine collision risk models and inform mitigation solutions; and b) monitor aerofauna interactions with terrestrial and offshore wind farms replacing costly human observers and allowing for long-term monitoring in the offshore environment. The camera system will provide developers and regulators with data on the risk that wind turbines present to aerofauna, which will reduce uncertainty in the environmental permitting process.

Adams, Evan↗

Hopping conduction in p-type MoS{sub 2} near the critical regime of the metal-insulator transition

We report on temperature-dependent charge and magneto transport of chemically doped MoS{sub 2}, p-type molybdenum disulfide degenerately doped with niobium (MoS{sub 2}:Nb). The temperature dependence of the electrical resistivity is characterized by a power law, ρ(T) ∼ T{sup −0.25}, which indicates that the system resides within the critical regime of the metal-insulator (M-I) transition. By applying high magnetic field (∼7 T), we observed a 20% increase in the resistivity at 2 K. The positive magnetoresistance shows that charge transport in this system is governed by the Mott-like three-dimensional variable range hopping (VRH) at low temperatures. According to relationship between magnetic-field and temperature dependencies of VRH resistivity, we extracted a characteristic localization length of 19.8 nm for MoS{sub 2}:Nb on the insulating side of the M-I transition.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Current nonclinical testing paradigm enables safe entry to First-In-Human clinical trials: The IQ consortium nonclinical to clinical translational database

The contribution of animal testing in drug development has been widely debated and challenged. An industry-wide nonclinical to clinical translational database was created to determine how safety assessments in animal models translate to First-In-Human clinical risk. The blinded database was composed of 182 molecules and contained animal toxicology data coupled with clinical observations from phase I human studies. Animal and clinical data were categorized by organ system and correlations determined. The 2 × 2 contingency table (true positive, false positive, true negative, false negative) was used for statistical analysis. Sensitivity was 48% with a 43% positive predictive value (PPV). The nonhuman primate had the strongest performance in predicting adverse effects, especially for gastrointestinal and nervous system categories. When the same target organ was identified in both the rodent and nonrodent, the PPV increased. Specificity was 84% with an 86% negative predictive value (NPV). The beagle dog had the strongest performance in predicting an absence of clinical adverse effects. If no target organ toxicity was observed in either test species, the NPV increased. While nonclinical studies can demonstrate great value in the PPV for certain species and organ categories, the NPV was the stronger predictive performance measure across test species and target organs indicating that an absence of toxicity in animal studies strongly predicts a similar outcome in the clinic. These results support the current regulatory paradigm of animal testing in supporting safe entry to clinical trials and provide context for emerging alternate models. - Highlights: • Translational database created to determine animal to human safety concordance. • 182 molecules with animal and clinical data; concordance parameters determined • Positive predictive value of 43%; Negative predictive value of 86% • Absence of toxicity in animal study strongly predicts similar outcome in the clinic. • Database supports animal testing to ensure human safety in the clinic.

60 APPLIED LIFE SCIENCES↗

SU-E-T-571: Newly Emerging Integrated Transmission Detector Systems Provide Online Quality Assurance of External Beam Radiation Therapy

Purpose: Two newly emerging transmission detectors positioned upstream from the patient have been evaluated for online quality assurance of external beam radiotherapy. The prototype for the Integral Quality Monitor (IQM), developed by iRT Systems GmbH (Koblenz, Germany) is a large-area ion chamber mounted on the linac accessory tray to monitor photon fluence, energy, beam shape, and gantry position during treatment. The ion chamber utilizes a thickness gradient which records variable response dependent on beam position. The prototype of Delta4 Discover™, developed by ScandiDos (Uppsala, Sweden) is a linac accessory tray mounted 4040 diode array that measures photon fluence during patient treatment. Both systems are employable for patient specific QA prior to treatment delivery. Methods: Our institution evaluated the reproducibility of measurements using various beam types, including VMAT treatment plans with both the IQM ion chamber and the Delta4 Discover diode array. Additionally, the IQM’s effect on photon fluence, dose response, simulated beam error detection, and the accuracy of the integrated barometer, thermometer, and inclinometer were characterized. The evaluated photon beam errors are based on the annual tolerances specified in AAPM TG-142. Results: Repeated VMAT treatments were measured with 0.16% reproducibility by the IQM and 0.55% reproducibility by the Delta4 Discover. The IQM attenuated 6, 10, and 15 MV photon beams by 5.43±0.02%, 4.60±0.02%, and 4.21±0.03% respectively. Photon beam profiles were affected <1.5% in the non-penumbra regions. The IQM’s ion chamber’s dose response was linear and the thermometer, barometer, and inclinometer agreed with other calibrated devices. The device detected variations in monitor units delivered (1%), field position (3mm), single MLC leaf positions (13mm), and photon energy. Conclusion: We have characterized two new transmissions detector systems designed to provide in-vivo like measurements upstream from the patient. Both systems demonstrate substantial utility for online treatment verification and QA of photon external beam radiotherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Assessment of Spatial Uncertainties in the Radiotherapy Process With the Novalis System

Purpose: The purpose of this study was to evaluate the accuracy of a new version of the ExacTrac X-ray (ETX) system with statistical analysis retrospectively in order to determine the tolerance of systematic components of spatial uncertainties with the Novalis system. Methods and Materials: Three factors of geometrical accuracy related to the ETX system were evaluated by phantom studies. First, location dependency of the detection ability of the infrared system was evaluated. Second, accuracy of the automated calculation by the image fusion algorithm in the patient registration software was evaluated. Third, deviation of the coordinate scale between the ETX isocenter and the mechanical isocenter was evaluated. From the values of these examinations and clinical experiences, the total spatial uncertainty with the Novalis system was evaluated. Results: As to the location dependency of the detection ability of the infrared system, the detection errors between the actual position and the detected position were 1% in translation shift and 0.1{sup o} in rotational angle, respectively. As to the accuracy of patient verification software, the repeatability and the coincidence of the calculation value by image fusion were good when the contrast of the X-ray image was high. The deviation of coordinates between the ETX isocenter and the mechanical isocenter was 0.313 {+-} 0.024 mm, in a suitable procedure. Conclusions: The spatial uncertainty will be less than 2 mm when suitable treatment planning, optimal patient setup, and daily quality assurance for the Novalis system are achieved in the routine workload.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-P-41: Imaging Coordination of Cone Beam CT, On-Board Image Conjunction with Optical Image Guidance for SBRT Treatment with Respiratory Motion Management

Purpose: To spare normal tissue for SBRT lung/liver patients, especially for patients with significant tumor motion, image guided respiratory motion management has been widely implemented in clinical practice. The purpose of this study was to evaluate imaging coordination of cone beam CT, on-board X-ray image conjunction with optical image guidance for SBRT treatment with motion management. Methods: Currently in our clinic a Varian Novlis Tx was utilized for treating SBRT patients implementing CBCT. A BrainLAB X-ray ExacTrac imaging system in conjunction with optical guidance was primarily used for SRS patients. CBCT and X-ray imaging system were independently calibrated with 1.0 mm tolerance. For SBRT lung/liver patients, the magnitude of tumor motion was measured based-on 4DCT and the measurement was analyzed to determine if patients would be beneficial with respiratory motion management. For patients eligible for motion management, an additional CT with breath holding would be scanned and used as primary planning CT and as reference images for Cone beam CT. During the SBRT treatment, a CBCT with pause and continuing technology would be performed with patients holding breath, which may require 3–4 partially scanned CBCT to combine as a whole CBCT depending on how long patients capable of holding breath. After patients being setup by CBCT images, the ExactTrac X-ray imaging system was implemented with patients’ on-board X-ray images compared to breath holding CT-based DRR. Results: For breath holding patients SBRT treatment, after initially localizing patients with CBCT, we then position patients with ExacTrac X-ray and optical imaging system. The observed deviations of real-time optical guided position average at 3.0, 2.5 and 1.5 mm in longitudinal, vertical and lateral respectively based on 35 treatments. Conclusion: The respiratory motion management clinical practice improved our physician confidence level to give tighter tumor margin for sparing normal tissue for SBRT lung/liver patients.

60 APPLIED LIFE SCIENCES↗

Identifying Wave-Packet Fractional Revivals by Means of Information Entropy

Wave-packet fractional revivals is a relevant feature in the long time-scale evolution of a wide range of physical systems, including atoms, molecules, and nonlinear systems. We show that the sum of information entropies in both position and momentum conjugate spaces is an indicator of fractional revivals by analyzing three different model systems: (i) the infinite square well, (ii) a particle bouncing vertically against a wall in a gravitational field, and (iii) the vibrational dynamics of hydrogen iodide molecules. This description in terms of information entropies complements the usual one in terms of the autocorrelation function.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Connectors for multicore optical fibers and methods thereof

The present invention relates to optical coupling systems that employ a multicore optical fiber. The system can be employed with two multicore optical fibers or with a single multicore optical fiber for use with an optical device. In particular, the system includes connectors having a lens assembly configured to relay optical signals and a ferrule to position the lens assembly. Additional details for making and using such systems are described herein.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Structural, electronic and magnetic properties of carbon doped boron nitride nanowire: Ab initio study

Using spin-polarized density functional theory calculations, we demonstrated that carbon doped boron nitride nanowire (C-doped BNNW) has diverse electronic and magnetic properties depending on position of carbon atoms and their percentages. Our results show that only when one carbon atom is situated on the edge of the nanowire, C-doped BNNW is transformed into half-metal. The calculated electronic structure of the C-doped BNNW suggests that doping carbon can induce localized edge states around the Fermi level, and the interaction among localized edge states leads to semiconductor to half-metal transition. Overall, the bond reconstruction causes of appearance of different electronic behavior such as semiconducting, half-metallicity, nonmagnetic metallic, and ferromagnetic metallic characters. The formation energy of the system shows that when a C atom is doped on surface boron site, system is more stable than the other positions of carbon impurity. Our calculations show that C-doped BNNW may offer unique opportunities for developing nanoscale spintronic materials.

36 MATERIALS SCIENCE↗

Dosimetric evaluation of two treatment planning systems for high dose rate brachytherapy applications

Various treatment planning systems are used to design plans for the treatment of cervical cancer using high-dose-rate brachytherapy. The purpose of this study was to make a dosimetric comparison of the 2 treatment planning systems from Varian medical systems, namely ABACUS and BrachyVision. The dose distribution of Ir-192 source generated with a single dwell position was compared using ABACUS (version 3.1) and BrachyVision (version 6.5) planning systems. Ten patients with intracavitary applications were planned on both systems using orthogonal radiographs. Doses were calculated at the prescription points (point A, right and left) and reference points RU, LU, RM, LM, bladder, and rectum. For single dwell position, little difference was observed in the doses to points along the perpendicular bisector. The mean difference between ABACUS and BrachyVision for these points was 1.88%. The mean difference in the dose calculated toward the distal end of the cable by ABACUS and BrachyVision was 3.78%, whereas along the proximal end the difference was 19.82%. For the patient case there was approximately 2% difference between ABACUS and BrachyVision planning for dose to the prescription points. The dose difference for the reference points ranged from 0.4-1.5%. For bladder and rectum, the differences were 5.2% and 13.5%, respectively. The dose difference between the rectum points was statistically significant. There is considerable difference between the dose calculations performed by the 2 treatment planning systems. It is seen that these discrepancies are caused by the differences in the calculation methodology adopted by the 2 systems.

61 RADIATION PROTECTION AND DOSIMETRY↗

Enabling Situation Awareness Under High Levels of Automation: Results From An Experimental Study

The Department of Energy’s Advanced Reactor Technologies (ART) program sponsors research, development and deployment activities through its Next Generation Nuclear Plant, Advanced Reactor Concepts, and Advanced Small Modular Reactor (aSMR) programs to promote safety, technical, economical, and environmental advancements of innovative Generation IV nuclear energy technologies. The Human Automation Collaboration (HAC) research project is located under the aSMR program, which identifies developing advanced instrumentation and controls and human-machine interfaces as one of four key research areas. New nuclear plants are expected to employ significantly more advanced technology than the systems in the current reactor fleet as well as utilize automation to a greater extent. However, advancing technology and increasing automation does not necessarily imply improved efficiency and safety of the plant. Instead, a number of concerns about how these technologies will affect human performance and the overall safety of the plant need to be addressed. More specifically, it is important to investigate how the operator and the automation work as a team to ensure effective and safe plant operation, also known as the human-automation collaboration (HAC). The HAC project at INL, investigates collaboration methods between a system’s automation and human operators and how that collaboration impacts the performance and reliability of overall system performance. Some well documented human performance issues associated with typical human automation collaboration methods include reduced operator situation awareness (SA), complacency, and over reliance on the system automation (Endsley, 1995, 1996, 1997; Endsley & Kaber, 1999; Kaber & Endsley, 1997, 2004; Parasuraman et al., 2000; Sheridan, 2002; Wickens & Hollands, 2000; Wright & Kaber, 2005). The HAC research effort addresses how to best design the collaboration between the operators and the automated systems in a manner that has the greatest positive impact on overall plant performance and reliability, hence addressing many of the documented issues. The ultimate goal of the HAC research effort is to develop design guidance that supports optimal interaction between humans and automated systems.

99 GENERAL AND MISCELLANEOUS↗

Molecular Investigation of Oxidized Graphene: Anatomy of the Double-Layer Structure and Ion Dynamics

We investigated the influence of surface oxidization of planar graphene electrodes on charge storage and ion dynamics of supercapacitors. Our approach compared two distinct ionic liquid (IL) electrolytes: tetraethylammonium tetrafluoroborate solvated in acetonitrile (TEA-BF4/ACN) and 1-ethyl-3-methylimidazolium bis(trifluoromethylsulfonyl)imide solvated in acetonitrile (EMIm-TFSI/ACN). Both experimental electrochemical tests and molecular dynamics (MD) simulations showed positive, electrolyte-specific influences of hydroxyl-free electrode interfaces on capacitance. In the EMIm-TFSI/ACN system, the hydroxylated surface, because of its strong interaction with anions, impeded surface charge storage. On the other hand, in the case of TEA-BF4/ACN, the distribution and orientation of ACN across the system exerted vital influence on the capacitance, especially on the positive hydroxyl-free electrode. Furthermore, MD simulations of ion mobility with respect to the electrode surface in the lateral and perpendicular directions revealed significantly slower diffusion performance on the oxidized surface. Our efforts enhanced the level of fundamental understanding of the effects of hydroxyl groups on electrode–electrolyte interfaces and resulting supercapacitor performance.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Dynamic performance of a passively self-adjusting floating wind farm layout to increase the annual energy production

One of the main differences between floating offshore wind turbines (FOWTs) and fixed-bottom turbines is the angular and translational motions of FOWTs. When it comes to planning a floating wind farm (FWF), the translational motions introduce an additional layer of complexity to the FWF layout. The ability of a FOWT to relocate its position represents an opportunity to mitigate wake losses within an FWF. By passively relocating downwind turbines out of the wake generated by upwind turbines, we can reduce wake-induced energy losses and enhance overall energy production. The translational movements of FOWTs are governed by the mooring system attached to it. The way a FOWT relocates its position changes if the design of the mooring system attached to it changes. Additionally, the translational motion of a FOWT attached to a given mooring system is different for different wind directions. Hence, we can tailor a mooring system design for a FOWT to passively control its motions according to the wind direction. In this work, we present a new self-adjusting FWF layout design and assess its performance using both static and dynamic methods. The results show that relocating the FOWTs in an FWF can increase the energy production by 3 % using a steady-state wake model and 1.4 % using a dynamic wake model at a wind speed of 10 m s -1 . Moreover, we compare the fatigue and ultimate loads of the mooring systems of the self-adjusting FWF layout design to the mooring systems in a current state-of-the-art FWF baseline design. The comparison shows that with smaller mooring system diameters, the self-adjusting FWF design has similar fatigue damage compared to the baseline design with bigger mooring system diameters at rated wind speed. Finally, the ultimate loads on the mooring systems of the self-adjusting FWF design are lower than those on the mooring systems of the baseline design.

17 WIND ENERGY↗

Functional but not taxonomic diversity increases productivity of Populus in the southeastern United States

Plant interactions like competition and facilitation impact ecosystem function and resilience. Improving our understanding of the relationships between these interactions and community productivity has important implications for managers of production systems in forestry and agriculture as well as conservation science. Populus spp. are an excellent model system for exploring how inter‐ and intraspecific interactions impact ecosystem functions, such as productivity, in forest plantations. In this study, we compared aboveground productivity of six Populus clones from three different taxa grown in monoclonal and mixed‐clonal plots. The different mixture treatments were intended to experimentally test aboveground biomass response to contrasting levels of taxonomic diversity and functional diversity based on nitrogen use characteristics of Populus clones. We hypothesize that functional diversity would be more important than taxonomic diversity in increasing aboveground productivity of mixed‐clonal plantings compared to monocultures. In addition, a subset of treatments was carried out on additional sites representing a productivity gradient in order to determine if the relationship between biodiversity and productivity in these systems diminished at more productive sites as suggested by the stress‐gradient hypothesis. We found that functionally diverse mixtures of clones had greater yield of aboveground biomass than the average of their constituent monocultures, while more taxonomically diverse mixes of clones did not differ from the average of their constituent monocultures. However, when reestablished on sites with extremely high or low productivity, the best performing clone mixture also did not differ from the average of its constituent monocultures. Our results suggest that intimate clone mixtures of Populus have the potential to significantly increase productivity, but results vary by mixture and by site. To capitalize on positive biodiversity effects on yield in production systems, targeted mixtures based on divergent functional traits linked to different use and acquisition strategies for site‐specific limiting resources are most likely to be successful.

BEF↗

DCS - A high flux beamline for time resolved dynamic compression science – Design highlights

The Dynamic Compression Sector (DCS) beamline, a national user facility for time resolved dynamic compression science supported by the National Nuclear Security Administration (NNSA) of the Department of Energy (DOE), has recently completed construction and is being commissioned at Sector 35 of the Advanced Photon Source (APS) at Argonne National Laboratory (ANL). The beamline consists of a First Optics Enclosure (FOE) and four experimental enclosures. A Kirkpatrick–Baez focusing mirror system with 2.2 mrad incident angles in the FOE delivers pink beam to the experimental stations. A refocusing Kirkpatrick–Baez mirror system is situated in each of the two most downstream enclosures. Experiments can be conducted in either white, monochromatic, pink or monochromatic-reflected beam mode in any of the experimental stations by changing the position of two interlocked components in the FOE. The beamline Radiation Safety System (RSS) components have been designed to handle the continuous beam provided by two in-line revolver undulators with periods of 27 and 30 mm, at closed gap, 150 mA beam current, and passing through a power limiting aperture of 1.5 x 1.0 mm{sup 2}. A novel pink beam end station stop [1] is used to stop the continuous and focused pink beam which can achieve a peak heat flux of 105 kW/mm{sup 2}. A new millisecond shutter design [2] is used to deliver a quick pulse of beam to the sample, synchronized with the dynamic event, the microsecond shutter, and the storage ring clock.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗