Search NASA⌕ Search

SEARCH · Search NASA

Results for “RESIDENTIAL”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,765 records · Page 98

LandScan HD: a high-resolution gridded ambient population methodology for the world

Unwarned population distributions accounting for routine human activities are needed to address many global human security challenges, including disasters, conflict, and infrastructure demand. LandScan High Definition (LSHD) supports this need through gridded ambient population estimates that measure average human presence between daytime and nighttime at a high spatial resolution of 3 arcseconds (approximately 90 m). Although LSHD has traditionally been produced on a country-specific basis, advances in global foundational data and computational resources now enable scaling its methodology to the world. Combining aspects of top-down and bottom-up gridded population methods, LSHD allocates subnational population totals from authoritative statistics to built-up areas based on occupancy estimates for multiple facility types (e.g., residential, commercial) and then reaggregates these estimates to a global population grid. We scale this approach by organizing the LSHD data stack into a 1° resolution tileset of vector analytic features, enabling an efficient and repeatable workflow for all countries worldwide. Examining the Philippines as an output of the global LSHD baseline dataset, we contrast unwarned and residential (WorldPop) population distributions by (1) exploring a practical application of flood risk assessment and (2) evaluating their congruence with outcomes of collective human activities (subnational CO 2 emissions). Finally, we discuss plans to address current LSHD limitations through data/modeling and uncertainty quantification improvements and provide outlook for workflow automation and extending the model to social, demographic and economic population characteristics.

Building morphology↗

A hybrid building thermal modeling approach for predicting temperatures in typical, detached, two-story houses

Within the residential building sector, the air-conditioning (AC) load is the main target for peak load shifting and reduction since it is the largest contributor to peak demand. By leveraging its power flexibility, residential AC is a good candidate to provide building demand response and peak load shifting. For realization of accurate and reliable control of AC loads, a building thermal model, which characterizes the properties of a building’s envelope and its thermal mass, is an essential component for accurate indoor temperature or cooling/heating demand prediction. Building thermal models include two types: “Forward” and “Data-Driven”. Due to time-saving and cost-effective characteristics, different data-driven models have been developed in a number of research studies. However, few developed models can predict temperatures in respective zones of a multiple-zone building with an open air path between zones e.g., an open stairwell connecting two floors of a home. In this research, a novel hybrid modeling approach is proposed to predict the average indoor air temperatures of both the upstairs and downstairs. This “hybrid” solution integrates both gray-box, i.e. RC model and black-box models. A developed RC model is used to predict the building mean temperature, and black-box model, in which the supervised machine learning algorithms are leveraged, is used to predict the temperature difference between the downstairs and upstairs. Compared with the measured data from a real house, the results obtained have acceptable/satisfactory accuracy. The method proposed in this study integrates the advantages of black-box and gray-box modeling. As a result, it can be used as a reliable alternative to predict the average temperatures in respective floors of typical detached two-story houses.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Distributed energy management for community microgrids considering network operational constraints and building thermal dynamics

A distributed energy management system for community microgrids is developed here. Unlike a centralized optimization-based energy management system, it schedules distributed energy resources and energy storage systems, as well as residential appliances, indirectly through iterative interaction between the microgrid central controller and home energy management systems, based on price signals. In each iteration, the microgrid central controller adjusts the scheduling of distributed energy resources and energy storage systems at the microgrid level. Meanwhile, the home energy management system of each house adjusts the scheduling of residential appliances. Then, the energy price at each bus is updated according to the unbalanced power between generation and demand. The optimization converges when the unbalanced power of all buses is close to zero, i.e., the microgrid central controller and home energy management systems reach an agreement on the energy price and generation/consumption. In particular, a detailed thermal dynamic model of the house is integrated into the HEMS scheduling for intelligent control of the heating, ventilation, and air-conditioning system by customers. Lastly, the distribution network is also considered to make the energy price signal locational. Results of case studies validate the efficacy of the proposed distributed energy management system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Impact of installation faults in air conditioners and heat pumps in single-family homes on U.S. energy usage

To ensure that new residential air conditioners and heat pumps operate optimally, care must be taken during the initial system design and installation to avoid missteps that immediately degrade a system’s performance. Laboratory and simulation studies have quantified the impact that faults can have on capacity and efficiency. Field studies have demonstrated that installation-related faults are commonplace. However, the national impact of installation-related faults cannot be accurately estimated by only simulating a limited number of homes at several fault levels because of the variety of home characteristics and climates involved. In our analysis, we use an improved residential building stock simulation tool to predict the annual energy increase and additional utility costs resulting from two common installation faults: indoor airflow rate and refrigerant charge level. Our method considers the wide range of building characteristics and climate zones of the U.S. housing stock. We use existing field data to develop fault intensity probability distributions to inform our analysis. The study shows that these two faults result in approximately 20.7 TWh/y of additional energy use for central air conditioners and air-source heat pumps in U.S. single-family detached homes, which is a 9% increase over baseline (no-fault) usage, costing homeowners approximately $2.5 billion annually on utility bills. Air-source heat pumps are responsible for a disproportionate fraction of this energy use increase because of the larger number of operating hours compared to central air conditioners and the sensitivity of heating mode performance to the faults analyzed compared to cooling mode.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Multiscale Effects Masked the Impact of the COVID-19 Pandemic on Electricity Demand in the United States

Shelter-in-place orders and business closures related to COVID-19 changed the hourly profile of electricity demand and created an unprecedented source of uncertainty for the grid. The potential for continued shifts in electricity profiles has implications for electricity sector investment and operating decisions that maintain reserve margins and provide grid reliability. This study reveals that understanding this uncertainty requires an understanding of the underlying drivers at the customer-class scale. This paper utilizes three datasets to compare the impacts of COVID-19 on electricity consumption across a range of spatiotemporal and customer scales. At the utility/customer-class scale, COVID-19-induced shutdowns in the spring of 2020 shifted weekday residential load profiles to resemble weekend profiles from previous years. Total commercial loads declined, but the commercial diurnal load profile was unchanged. With only total loads available at the balancing authority scale, the apparent impact of COVID-19 was smaller during the summer due in part to phased re-opening and spatial variability in re-opening, but there were still clear variations once total loads were broken down zonally. Monthly data at the state scale showed an increase in state-level residential electricity sales, a decrease in commercial sales, and a small net decrease in total sales in most states from April-August 2020. Analyses that focus on total load or a single scale may miss important changes that become apparent when the load is broken down regionally or by customer class.

COVID-19, electricity demand, multiscale, Commonwe↗

Heating performance of a vapor compression heat pump cascaded with a thermoelectric heat pump

Air source heat pumps (ASHPs) are widely utilized for heating and cooling in residential buildings; however, their effectiveness in heating mode is compromised during extreme weather conditions. Extensive research endeavors have been undertaken to develop, test, and assess a cost-effective vapor compression ASHP suitable for cold climate regions. Further, this study takes an innovative approach by developing component and system prototypes for a cold climate heat pump. This design combines a thermoelectric heat pump (TEHP) with a traditional residential split ASHP to augment heating capacity in low ambient temperature conditions. The component and system prototypes underwent experimental testing in the psychrometric chambers. The experimental findings revealed a 13.6% to 13.7% increase in total heat pump heating capacity, accompanied by a 3.1% to 5.0% decrease in the coefficient of performance (COP) at ambient temperatures of -15°C and -19°C, when compared to the original ASHP. The COP of the TEHP is relatively constant, ranging from 1.63 to 1.76. This prototype offers a solution to address the challenges associated with reduced heat pump capacity at low ambient temperatures. The experimental results indicated that the lower the ambient temperature, thermoelectric heat pump auxiliary heating can increase the heating efficiency 60% in comparison to electric resistance.

42 ENGINEERING↗

Black carbon emissions from biomass and coal in rural China

Residential solid fuel combustion makes a major contribution to black carbon (BC) emissions in China. A new estimation of BC emissions from rural solid biomass and coal consumption has been derived from field survey data. The following new contributions are made: (1) emission factors are collected and reviewed; (2) household energy data are collected from field survey data and from the literature; (3) a new extrapolation method is developed to extend the field survey data to other locations; (4) the ownership and usage of two stove types are estimated and considered in the emission calculations; and (5) uncertainties associated with the estimation results are quantified. It is shown that rural households with higher income will consume less biomass but more coal. Agricultural acreage and temperature also significantly influence the amount of solid fuel consumed in rural areas. It is estimated that 640±245 Gg BC/y were emitted to the atmosphere due to residential solid fuel consumption in rural China in 2014. Emissions of BC from straw, wood, and coal contributed 42±13%, 36±15%, and 22±10% of the total, respectively. As a result, we show that effective BC mitigation (a reduction of 47%) could be obtained through widespread introduction of improved stoves in rural households

01 COAL, LIGNITE, AND PEAT↗

Developing a landscape of urban building energy use with improved spatiotemporal representations in a cool-humid climate

Urban buildings account for up to 75% of total energy use in the United States (U.S.). Understanding urban building energy use is important for developing feasible options to mitigate energy use and greenhouse gas emissions. In this study, an improved bottom-up building energy use model, named City Building Energy Use Model (City-BEUM), was developed to estimate building energy use for all buildings in Polk County, Iowa. First, 28 commercial and 6 residential building prototypes were designed by combing Assessor's parcel data and building footprint data. Then, the EnergyPlus in the CityBEUM was calibrated for all building prototypes using the U.S. Energy Information Administration's survey data, monthly utility meter data, and actual weather data. Finally, spatial and temporal variations of building energy use in the study area were estimated using the CityBEUM. Results indicate that the spatial variation of building energy use in the study area can be captured using the CityBEUM. With the monthly-calibrated model, the temporal pattern of urban building energy use can be well represented. The comparison of building energy use using the Typical Meteorological Year and actual weather data demonstrates the importance of using actual weather data in building energy modeling for an improved temporal representation.

CityBEUM, Urban building energy use, High spatiote↗

Sensitivity of occupant comfort models to humidity and their effect on cooling energy use

Residential building energy consumption in the United States has decreased steadily during the last several decades largely because of advances in building codes as well as voluntary efficiency and labeling programs, which have resulted in the reduction in building sensible loads. Building latent loads have not decreased by the same amount, and field and analytical research studies have concluded that high-efficiency, low-load homes often have elevated indoor humidity levels, possibly leading to occupant discomfort. There are discrepancies in the literature on occupant comfort as it relates to indoor humidity and recommended upper humidity limits. The choice of humidity limit could potentially change results and conclusions on the energy impacts of a new air conditioner or dehumidifier technology, changing ventilation rates, or an improved building envelope. In this study, we use building simulations to explore the impact of humidity control on cooling energy use in efficient residential buildings for different humidity limits. We look at limits based on humidity ratio (or dew point temperature), wet-bulb temperature, relative humidity, and constant slope lines based on the popular comfort models of both Fanger and Gagge. We quantify the additional energy use required to control humidity below these limits. We look at the sensitivity of the results to different temperature and humidity set points, occupant internal gains, moisture buffering levels, evaporator airflow rates, and dehumidifier energy factors. High-efficiency home predicted energy savings are more sensitive to the assumed humidity limit and cooling and dehumidification set points than the other parameters investigated in this paper.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A simulation-based assessment of technologies to reduce heat emissions from buildings

Heat emissions from buildings are part of anthropogenic heat leading to urban overheating. This paper aims to assess how technologies (i.e., energy conservation measures - ECMs), used to decrease energy use, may also reduce heat emissions from buildings. This study employs the physics-based engine EnergyPlus to simulate the main components of heat emissions from buildings to ambient air: envelope, zone, and systems. Hourly simulations are run for IECC single- and multi-family reference models with three representative climates: Miami, Baltimore, and Chicago. The results show that the performance of ECMs varies among weather, seasons, and residential typologies. Particularly, some ECMs (i.e., cool coatings, heat pumps, additional insulation, energy-awareness occupants) show a strong decrease in heat emissions, yet they are not always correlated with proportional decreases in energy use. When all ECMs are combined, the reductions are larger on heat emissions (89%) than on site energy (65%) from the base cases. During summer in Miami, the combination of ECMs shows a decrease in heat emissions from the building surface component of 80% during daytime, 92% for the HVAC component and a counterbalanced increase in the zone component of 88%, bringing to a daily decrease in total heat emissions. The main contributions of this study are quantifying how typical ECMs influence residential building heat emissions using EnergyPlus simulations and informing urban planners and stakeholders on prioritizing measures for mitigating urban overheating problems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluation of energy savings potential of variable refrigerant flow (VRF) from variable air volume (VAV) in the U.S. climate locations

Variable refrigerant flow (VRF) systems are known for their high energy performance and thus can improve energy efficiency both in residential and commercial buildings. The energy savings potential of this system has been demonstrated in several studies by comparing the system performance with conventional HVAC systems such as rooftop variable air volume systems (RTU-VAV) and central chiller and boiler systems. This paper evaluates the performance of VRF and RTU-VAV systems in a simulation environment using widely-accepted whole building energy modeling software, EnergyPlus. A medium office prototype building model, developed by the U.S. Department of Energy (DOE), is used to assess the performance of VRF and RTU-VAV systems. Each system is placed in 16 different locations, representing all U.S. climate zones, to evaluate the performance variations. Both models are compliant with the minimum energy code requirements prescribed in ASHRAE standard 90.1-2010 — energy standard for buildings except low-rise residential buildings. Finally, a comparison study between the simulation results of VRF and RTU-VAV models is made to demonstrate energy savings potential of VRF systems. The simulation results show that the VRF systems would save around 15–42% and 18–33% for HVAC site and source energy uses compared to the RTU-VAV systems. In addition, calculated results for annual HVAC cost savings point out that hot and mild climates show higher percentage cost savings for the VRF systems than cold climates mainly due to the differences in electricity and gas use for heating sources.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Health impact assessment of air pollution using a dynamic exposure profile: Implications for exposure and health impact estimates

In both ambient air pollution epidemiology and health impact assessment an accurate assessment of the population exposure is crucial. Although considerable advances have been made in assessing human exposure outdoors, the assessments often do not consider the impact of individual travel behavior on such exposures. Population-based exposures to NO{sub 2} and O{sub 3} using only home addresses were compared with models that integrate all time-activity patterns-including time in commute-for Flanders and Brussels. The exposure estimates were used to estimate the air pollution impact on years of life lost due to respiratory mortality. Health impact of NO{sub 2} using an exposure that integrates time-activity information was on average 1.2% higher than when assuming that people are always at their home address. For ozone the overall estimated health impact was 0.8% lower. Local differences could be much larger, with estimates that differ up to 12% from the exposure using residential addresses only. Depending on age and gender, deviations from the population average were seen. Our results showed modest differences on a regional level. At the local level, however, time-activity patterns indicated larger differences in exposure and health impact estimates, mainly for people living in more rural areas. These results suggest that for local analyses the dynamic approach can contribute to an improved assessment of the health impact of various types of pollution and to the understanding of exposure differences between population groups. - Highlights: Black-Right-Pointing-Pointer Exposure to ambient air pollution was assessed integrating population mobility. Black-Right-Pointing-Pointer This dynamic exposure was integrated into a health impact assessment. Black-Right-Pointing-Pointer Differences between the dynamic and residential exposure were quantified. Black-Right-Pointing-Pointer Modest differences in health impact were found at a regional level. Black-Right-Pointing-Pointer At municipal level larger differences were found, influenced by gender and age.

54 ENVIRONMENTAL SCIENCES↗

Unanticipated potential cancer risk near metal recycling facilities

Metal recycling is an important growing industry. Prior to this study, area sources consisting of metal recycling facilities fell in a category of limited regulatory scrutiny because of assumed low levels of annual emissions. Initiating with community complaints of nuisance from smoke, dust and odor, the Houston Department of Health and Human Services (HDHHS) began a monitoring program outside metal recycler facilities and found metal particulates in outdoor ambient air at levels which could pose a carcinogenic human health risk. In a study of five similar metal recycler facilities which used a torch cutting process, air downwind and outside the facility was sampled for eight hours between 6 and 10 times each over 18 months using a mobile laboratory. Ten background locations were also sampled. Iron, manganese, copper, chromium, nickel, lead, cobalt, cadmium and mercury were detected downwind of the metal recyclers at frequencies ranging from 100% of the time for iron to 2% of the time for mercury. Of these metals, chromium, nickel, lead, cobalt, cadmium and mercury were not detected in any sample in the background. Two pairs of samples were analyzed for total chromium and hexavalent chromium to establish a ratio of the fraction of hexavalent chromium in total chromium. This fraction was used to estimate hexavalent chromium at all locations. The carcinogenic risk posed to a residential receptor from metal particulate matter concentrations in the ambient air attributed to the metal recyclers was estimated from each of the five facilities in an effort to rank the importance of this source and inform the need for further investigation. The total risk from these area sources ranged from an increased cancer risk of 1 in 1,000,000 to 6 in 10,000 using the 95th upper confidence limit of the mean of the carcinogenic metal particulate matter concentration, assuming the point of the exposure is the sample location for a residential receptor after accounting for wind direction and the number of shifts that could operate a year. Further study is warranted to better understand the metal air pollution levels in the community and if necessary, to evaluate the feasibility of emission controls and identify operational improvements and best management practices for this industry. This research adds two new aspects to the literature: identification of types and magnitude of metal particulate matter air pollutants associated with a previously unrecognized area source, metal recyclers and their potential risk to health. -- Highlights: • Air monitoring study in response to community complaints found metal contamination. • Metal recyclers found to potentially pose cancer from metal particulates • Chromium, nickel, cobalt and cadmium samples were detected in five metal recyclers. • These metals were not detected in background air samples. • Estimated increased cancer risk ranges from 1 in 1,000,000 to 8 in 10,000.

54 ENVIRONMENTAL SCIENCES↗

A program-level management system for the life cycle environmental and economic assessment of complex building projects

Climate change has become one of the most significant environmental issues, of which about 40% come from the building sector. In particular, complex building projects with various functions have increased, which should be managed from a program-level perspective. Therefore, this study aimed to develop a program-level management system for the life-cycle environmental and economic assessment of complex building projects. The developed system consists of three parts: (i) input part: database server and input data; (ii) analysis part: life cycle assessment and life cycle cost; and (iii) result part: microscopic analysis and macroscopic analysis. To analyze the applicability of the developed system, this study selected ‘U’ University, a complex building project consisting of research facility and residential facility. Through value engineering with experts, a total of 137 design alternatives were established. Based on these alternatives, the macroscopic analysis results were as follows: (i) at the program-level, the life-cycle environmental and economic cost in ‘U’ University were reduced by 6.22% and 2.11%, respectively; (ii) at the project-level, the life-cycle environmental and economic cost in research facility were reduced 6.01% and 1.87%, respectively; and those in residential facility, 12.01% and 3.83%, respective; and (iii) for the mechanical work at the work-type-level, the initial cost was increased 2.9%; but the operation and maintenance phase was reduced by 20.0%. As a result, the developed system can allow the facility managers to establish the operation and maintenance strategies for the environmental and economic aspects from a program-level perspective. - Highlights: • A program-level management system for complex building projects was developed. • Life-cycle environmental and economic assessment can be conducted using the system. • The design alternatives can be analyzed from the microscopic perspective. • The system can be used to establish the optimal O&M strategy at the program-level. • It can be applied to any other country or sector in the global environment.

54 ENVIRONMENTAL SCIENCES↗

Developing micro-level urban ecosystem indicators for sustainability assessment

Sustainability assessment is increasingly being viewed as an important tool to aid in the shift towards sustainable urban ecosystems. An urban ecosystem is a dynamic system and requires regular monitoring and assessment through a set of relevant indicators. An indicator is a parameter which provides information about the state of the environment by producing a quantitative value. Indicator-based sustainability assessment needs to be considered on all spatial scales to provide efficient information of urban ecosystem sustainability. The detailed data is necessary to assess environmental change in urban ecosystems at local scale and easily transfer this information to the national and global scales. This paper proposes a set of key micro-level urban ecosystem indicators for monitoring the sustainability of residential developments. The proposed indicator framework measures the sustainability performance of urban ecosystem in 3 main categories including: natural environment, built environment, and socio-economic environment which are made up of 9 sub-categories, consisting of 23 indicators. This paper also describes theoretical foundations for the selection of each indicator with reference to the literature [Turkish] Highlights: • As the impacts of environmental problems have multi-scale characteristics, sustainability assessment needs to be considered on all scales. • The detailed data is necessary to assess local environmental change in urban ecosystems to provide insights into the national and global scales. • This paper proposes a set of key micro-level urban ecosystem indicators for monitoring the sustainability of residential developments. • This paper also describes theoretical foundations for the selection of each indicator with reference to the literature.

54 ENVIRONMENTAL SCIENCES↗

High-performance windows improve thermal survivability of occupants during cold snaps

Exposure to low indoor air temperature is a major contributor to temperature-related mortality during extreme cold events, especially when power outages disrupt operation of space heating systems. This study explores the impact of high-performance windows on the thermal resilience of residential buildings during extreme cold weather and grid power outages, as well as their long-term benefits through energy efficiency and reduced risk of property damage. Building performance simulations were conducted for reference residential buildings in three construction vintages and two major U.S. cities located in cold climate zones, considering two types of extreme cold events: short and severe, and long and milder. Our research found that even houses compliant with current energy codes struggle to maintain safe indoor temperatures for more than a few hours during power outages, necessitating rapid evacuations. High-performance windows can extend the thermal survivability time by up to 3.8 days within a 7-day cold snap and significantly reduce risk of bursting frozen water pipes, depending on the building’s insulation and infiltration level, cold event severity, and occupant vulnerability. This extended thermal safety time is crucial in scenarios where reduced mobility complicates emergency responses in senior housing. In addition to boosting thermal resilience, upgrading older homes with high-performance windows can reduce heating energy consumption by over 18% and cooling energy by 15%. Our findings highlight the need to incorporate thermal resilience assessments into new designs or major retrofits, including the use of typical and extreme weather scenarios and advanced technologies like high-performance windows.

Krelling, Amanda F↗

Numerical simulation of buoyancy-driven turbulent ventilation in attic space under winter conditions

Attic design and construction have significant impacts on residential buildings’ energy performance. In order to understand how passive ventilation rates affect ridge-vent attic's performance, a two-dimensional steady-state finite volume model is employed to simulate the buoyancy-driven turbulent ventilation and heat transfer in a triangular attic space of a gable-roof residential building under winter conditions. The modeled attic has a pitch of 5/12 and a passive ventilation system, consisting of continuous ridge and soffit vents. The v2f model is used to analyze the turbulent air flow and natural convection heat transfer inside the attic. The effects of ambient air temperature, vent size, and ceiling insulation on heating load and ice dam formation are investigated. The thermal performance of the vented attic is compared with a sealed attic as well. Here, the simulation results reveal that symmetrical air flow patterns exist in a vented attic, in contrast to the asymmetrical air flow patterns found in a sealed attic. In addition, it is suggested that increasing vent size results in higher ventilation air flow rate but barely affects the attic heating load, and that both sufficient ventilation and insulation are needed to ensure the proper functions of the attic and its energy efficiency.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗