Search NASA⌕ Search

SEARCH · Search NASA

Results for “Scanning techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,765 records · Page 98

Curved grating fabrication techniques for concentric-circle grating, surface-emitting semiconductor lasers

We describe the fabrication and operational characteristics of a novel, surface-emitting semiconductor laser that makes use of a concentric-circle grating to both define its resonant cavity and to provide surface emission. A properly fabricated circular grating causes the laser to operate in radially inward- and outward-going circular waves in the waveguide, thus, introducing the circular symmetry needed for the laser to emit a beam with a circular cross-section. The basic circular-grating-resonator concept can be implemented in any materials system; an AlGaAs/GaAs graded-index, separate confinement heterostructure (GRINSCH), single-quantum-well (SQW) semiconductor laser, grown by molecular beam epitaxy (MBE), was used for the experiments discussed here. Each concentric-circle grating was fabricated on the surface of the AlGaAs/GaAs semiconductor laser. The circular pattern was first defined by electron-beam (e-beam) lithography in a layer of polymethylmethacrylate (PMMA) and subsequently etched into the semiconductor surface using chemically-assisted (chlorine) ion-beam etching (CAIBE). We consider issues that affect the fabrication and quality of the gratings. These issues include grating design requirements, data representation of the grating pattern, and e-beam scan method. We provide examples of how these techniques can be implemented and their impact on the resulting laser performance. A comparison is made of the results obtained using two fundamentally different electron-beam writing systems. Circular gratings with period lambda = 0.25 microns and overall diameters ranging from 80 microns to 500 microns were fabricated. We also report our successful demonstration of an optically pumped, concentric-circle grating, semiconductor laser that emits a beam with a far-field divergence angle that is less than one degree. The emission spectrum is quite narrow (less than 0.1 nm) and is centered at wavelength lambda = 0.8175 microns.

Jordan, Rebecca H.↗

SU-E-T-161: Characterization and Validation of CT Simulator Hounsfield Units to Relative Stopping Power Values for Proton Treatment Planning

Purpose: To develop a calibration curve that includes and minimizes the variations of Hounsfield Unit (HU) from a CT scanner to Relative Stopping Power (RSP) of tissues along the proton beam path. The variations are due to scanner and proton energy, technique, phantom size and placement, and tissue arrangement. Methods: A CIRS 062 M phantom with 10 plugs of known relative electron density (RED) was scanned through a 16 slice GE Discovery CT Simulator scanner. Three setup combinations of plug distributions and techniques clinically implemented for five treatment regions were scanned with energies of 100, 120, and 140 kV. Volumetric HU values were measured for each plug and scan. The RSP values derived through the Bethe-Bloch formula are currently being verified with parallel-plate ionization chamber measurements in water using 80, 150, and 225 MeV proton beam. Typical treatment plans for treatment regions of brain, head-&-neck, chest, abdomen, and pelvis are being planned and dose delivered will be compared with film and Optically Stimulated Luminescence (OSL) measurements. Results: Percentage variations were determined for each variable. For tissues close to water, variations were <1% from any given parameter. Tissues far from water equivalence (lung and bone) showed the greatest sensitivity to change (7.4% maximum) with scanner energy and up to 5.3% with positioning of the phantom. No major variations were observed for proton energies within the treatment range. Conclusion: When deriving a calibration curve, attention should be placed to low and high HU values. A thorough verification process of calculated vs. water-phantom measured RSP values at different proton energies, followed by dose validation of planned vs. measured doses in phantom with film and OSL detectors are currently being undertaken.

60 APPLIED LIFE SCIENCES↗

Correlation between Antimicrobial Activity and Bioactivity of Na-Mica and Na-Mica/Fluorapatite Glass and Glass-Ceramics and Their Corrosion Protection of Titanium in Simulated Body Fluid

The improvement in bioactivity of titanium (Ti) surface was achieved via coating it with Na-mica and Na-mica/fluorapatite glass and glass-ceramic using the low-cost electrophoretic deposition technique. Two compositions from pure Na-mica (M) and 80 Na-mica/20 fluorapatite glasses (MF) were prepared in the system SiO{sub 2}-Al{sub 2}O{sub 3}-MgO-MgF{sub 2}-Na{sub 2}O-B{sub 2}O{sub 3} using melting–quenching technique. Characterization of the as-prepared glasses and their counterpart glass-ceramics was studied using differential thermal analysis (DTA), x-ray diffraction (XRD), Scanning Electron Microscopy (SEM) and Fourier Transform-IR (FTIR) spectroscopy techniques. The bioactivity behavior was proved by studying the XRD, FTIR and SEM after immersing both glass and glass-ceramic samples in simulated body fluid (SBF). Both M and MF glasses and glass-ceramics showed high microhardness measurements and good antibacterial behavior. In vitro biodegradation was studied by using electrochemical corrosion behavior of the prepared glass- and glass-ceramic-coated Ti in SBF. The prepared coated Ti showed good corrosion resistance in SBF at 37 °C using potentiodynamic polarization technique, and the impedance data fitting explained the structure of the coating and the adsorption of SBF ions on the Ti surface. The MFGC provides the best corrosion-resistant coating, especially after sintering it.

36 MATERIALS SCIENCE↗

Double perovskite oxides Sr{sub 2}MMoO{sub 6} (M = Fe and Co) as cathode materials for oxygen reduction in alkaline medium

Graphical abstract: The oxygen reduction over the surface of the electrocatalysts exhibiting high currents shows that SCMO/C electrocatalyst is slightly more active than the SFMO/C one. The relatively high electrochemical activity of the first may be ascribed to its high specific surface area providing a higher electrode current. Highlights: Black-Right-Pointing-Pointer SCMO/C and SFMO/C as catalysts for oxygen reduction were studied. Black-Right-Pointing-Pointer SCMO/C catalyst showed a relatively high activity. Black-Right-Pointing-Pointer A change in the reaction mechanism from a direct 'four-electron pathway' to a 'peroxide pathway' was observed. -- Abstract: The oxygen reduction reaction (ORR) was studied on Sr{sub 2}MMoO{sub 6} (M = Fe and Co) double perovskites, prepared by a solid-state reaction, in 0.5 M NaOH at 25 Degree-Sign C with a rotating disk electrode (RDE). The two oxide powders were characterized by X-ray diffraction, scanning electron microscopy and BET analysis. The electrochemical techniques considered are linear voltammetry, steady state polarization and ac impedance spectroscopy. The electrocatalysts (SFMO/C, SCMO/C) consisting of the double perovskite oxides and carbon (Vulcan XC-72) were mixed and spread out into a thin layer on a glassy carbon substrate. At room temperature, a significantly electrocatalytic activity is observed for both electrocatalysts. Compared to SFMO/C, the SCMO/C electrocatalyst was found to show a relatively high electrocatalytic activity for O{sub 2} reduction, which agrees well with the results obtained using the ac impedance spectroscopy.

36 MATERIALS SCIENCE↗

Revisiting matrix-based inversion of scanning mobility particle sizer (SMPS) and humidified tandem differential mobility analyzer (HTDMA) data

Abstract. Tikhonov regularization is a tool for reducing noise amplification during data inversion. This work introduces RegularizationTools.jl, a general-purpose software package for applying Tikhonov regularization to data. The package implements well-established numerical algorithms and is suitable for systems of up to ∼ 1000 equations. Included is an abstraction to systematically categorize specific inversion configurations and their associated hyperparameters. A generic interface translates arbitrary linear forward models defined by a computer function into the corresponding design matrix. This obviates the need to explicitly write out and discretize the Fredholm integral equation, thus facilitating fast prototyping of new regularization schemes associated with measurement techniques. Example applications include the inversion involving data from scanning mobility particle sizers (SMPSs) and humidified tandem differential mobility analyzers (HTDMAs). Inversion of SMPS size distributions reported in this work builds upon the freely available software DifferentialMobilityAnalyzers.jl. The speed of inversion is improved by a factor of ∼ 200, now requiring between 2 and 5 ms per SMPS scan when using 120 size bins. Previously reported occasional failure to converge to a valid solution is reduced by switching from the L-curve method to generalized cross-validation as the metric to search for the optimal regularization parameter. Higher-order inversions resulting in smooth, denoised reconstructions of size distributions are now included in DifferentialMobilityAnalyzers.jl. This work also demonstrates that an SMPS-style matrix-based inversion can be applied to find the growth factor frequency distribution from raw HTDMA data while also accounting for multiply charged particles. The outcome of the aerosol-related inversion methods is showcased by inverting multi-week SMPS and HTDMA datasets from ground-based observations, including SMPS data obtained at Bodega Marine Laboratory during the CalWater 2/ACAPEX campaign and co-located SMPS and HTDMA data collected at the US Department of Energy observatory located at the Southern Great Plains site in Oklahoma, USA. Results show that the proposed approaches are suitable for unsupervised, nonparametric inversion of large-scale datasets as well as inversion in real time during data acquisition on low-cost reduced-instruction-set architectures used in single-board computers. The included software implementation of Tikhonov regularization is freely available, general, and domain-independent and thus can be applied to many other inverse problems arising in atmospheric measurement techniques and beyond.

54 ENVIRONMENTAL SCIENCES↗

Growth mechanism and surface atomic structure of AgInSe{sub 2}

The growth of (112)A-oriented AgInSe{sub 2} on GaAs (111)A and its surface reconstruction were studied by scanning tunneling microscopy, atomic force microscopy, and other techniques. Films were grown by a sputtering and evaporation method. Topographic STM images reveal that the film grew by atomic incorporation into surface steps resulting from screw dislocations on the surface. The screw dislocation density was {approx}10{sup 10} cm{sup 2}. Atomically resolved images also show that the surface atomic arrangement appears to be similar to that of the bulk, with a spacing of 0.35-0.41 nm. There is no observable reconstruction, which is unexpected for a polar semiconductor surface.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

SU-E-I-51: Use of Blade Sequences in Cervical Spine MR Imaging for Eliminating Motion, Truncation and Flow Artifacts

Purpose: To assess the efficacy of the BLADE technique to eliminate motion, truncation, flow and other artifacts in Cervical Spine MRI compared to the conventional technique. To study the ability of the examined sequences to reduce the indetention and wrap artifacts, which have been reported in BLADE sagittal sequences. Methods: Forty consecutive subjects, who had been routinely scanned for cervical spine examination using four different image acquisition techniques, were analyzed. More specifically, the following pairs of sequences were compared: a) T2 TSE SAG vs. T2 TSE SAG BLADE and b) T2 TIRM SAG vs. T2 TIRM SAG BLADE. A quantitative analysis was performed using the signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) and relative contrast (ReCon) measures. A qualitative analysis was also performed by two radiologists, who graded seven image characteristics on a 5-point scale (0:non-visualization; 1:poor; 2:average; 3:good; 4:excellent). The observers also evaluated the presence of image artifacts (motion, truncation, flow, indentation). Results: Based on the findings of the quantitative analysis, the ReCON values of the CSF (cerebrospinal fluid)/SC (spinal cord) between TIRM SAG and TIRM SAG BLADE were found to present statistical significant differences (p<0.001). Regarding motion and truncation artifacts, the T2 TSE SAG BLADE was superior compared to the T2 TSE SAG and the T2 TIRM SAG BLADE was superior compared to the T2 TIRM SAG. Regarding flow artifacts, T2 TIRM SAG BLADE eliminated more artifacts compared to the T2 TIRM SAG. Conclusion: The use of BLADE sequences in cervical spine MR examinations appears to be capable of potentially eliminating motion, pulsatile flow and trancation artifacts. Furthermore, BLADE sequences are proposed to be used in the standard examination protocols based on the fact that a significantly improved image quality could be achieved.

60 APPLIED LIFE SCIENCES↗

Preparation and Determination of Antimicrobial Property of Cation-Exchanged Ecuadorian Natural Zeolite to be Used as Filler for Polyethylene and Polypropylene Matrices

Zeolites are crystalline aluminosilicates with nanoporous structure, tasteless and non-toxic materials. In this study, silver ion-exchanged zeolite, which was prepared from the natural Ecuadorian zeolites was used as reinforcement material in low-density polyethylene (LDPE) and polypropylene (PP). Polymers were filled with 1, 2 and 3 wt% concentrations of natural zeolite (Z) and silver ion exchanged zeolite (ZA). Zeolites and composites were characterized by X-ray diffractometry, Fourier transform infrared spectroscopy, scanning electron microscope, thermogravimetric analysis and mechanical analysis techniques. Microbiological analysis of silver ion exchanged zeolite showed effective antibacterial property against Escherichia coli bacteria. PP/ZA composites showed better tensile strengths in all mixes comparing to pure PP. ZAPE2 and ZAPP1 showed the best mechanical properties among all the composites based on polyethylene and PP, respectively. The composites prepared are potential candidates to be used in food packaging, and ZA type zeolites can be used as filler for the preparation of various composites.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Synthesis of TiO{sub 2} core/RuO{sub 2} shell particles using multistep ultrasonic spray pyrolysis

Graphical abstract: - Highlights: • TiO{sub 2} core/RuO{sub 2} shell submicron-particles were prepared via a sequential spray pyrolysis. • Spherical particles have the mean particle diameters between 200 and 400 nm. • This method is promising for synthesis of core–shell and core–multishell materials. - Abstract: Spherical submicron-particles with TiO{sub 2} core–RuO{sub 2} shell structure have been synthesized by employing sequential ultrasonic spray pyrolysis. The particles have been investigated by X-ray powder diffraction, scanning electron microscopy and different transmission electron microscopy techniques. The quality of the core–shell structure of the particles has been confirmed by comparison of the experimental data with those generated on the basis of a hard sphere core–shell model. It has been found that the mixing of the Ru-containing aerosol with the TiO{sub 2} particle stream has a significant impact on the core–shell formation. The method introduced in this study can probably be applied for preparation of core–shell and core–multishell materials that are difficult to synthesize in a single step spray pyrolysis process.

36 MATERIALS SCIENCE↗

One-Dimensional Scanning Approach to Shock Sensing

Measurement tools for high speed air flow are sought both in industry and academia. Particular interest is shown in air flows that exhibit aerodynamic shocks. Shocks are accompanied by sudden changes in density, pressure, and temperature. Optical detection and characterization of such shocks can be difficult because the medium is normally transparent air. A variety of techniques to analyze these flows are available, but they often require large windows and optical components as in the case of Schlieren measurements and/or large operating powers which precludes their use for in-flight monitoring and applications. The one-dimensional scanning approach in this work is a compact low power technique that can be used to non-intrusively detect shocks. The shock is detected by analyzing the optical pattern generated by a small diameter laser beam as it passes through the shock. The optical properties of a shock result in diffraction and spreading of the beam as well as interference fringes. To investigate the feasibility of this technique a shock is simulated by a 426 m diameter optical fiber. Analysis of results revealed a direct correlation between the optical fiber or shock location and the beam s diffraction pattern. A plot of the width of the diffraction pattern vs. optical fiber location reveals that the width of the diffraction pattern was maximized when the laser beam is directed at the center of the optical fiber. This work indicates that the one-dimensional scanning approach may be able to determine the location of an actual shock. Near and far field effects associated with a small diameter laser beam striking an optical fiber used as a simulated shock are investigated allowing a proper one-dimensional scanning beam technique.

Tokars, Roger↗

Structural dependence of piezoelectric, dielectric and ferroelectric properties of K{sub 0.5}Na{sub 0.5}(Nb{sub 1−2x/5}Cu{sub x})O{sub 3} lead-free ceramics with high Q{sub m}

Graphical abstract: Display Omitted Highlights: ► Double hysteresis loops were observed in K{sub 0.5}Na{sub 0.5}(Nb{sub 1−2x/5}Cu{sub x})O{sub 3}. ► Cu substitution caused structural discontinuity in KNNC. ► Dimeric defect complex (Cu{sup ‴}{sub Nb}–V{sub O}··){sup ′} with a dipole moment was formed in KNNC. -- Abstract: (K{sub 0.5}Na{sub 0.5})(Nb{sub 1−2x/5}Cu{sub x})O{sub 3} (abbreviated as KNNC, x = 0–2%) lead-free ceramics were synthetized by the solid state solution method. Pure perovskite phase with orthorhombic symmetry was observed. The evolution of the structure of KNNC was examined by X-ray diffraction (XRD), scanning electron microscopy (SEM) and Raman scattering spectra techniques. Our results revealed that, defect dipoles (Cu{sup ‴}{sub Nb}–V{sub O}··){sup ′} were formed and provided a restoring force to reverse the switched polarization, which resulted in double P–E hysteresis loops in KNNC with Cu doping at x = 0.75% and 1%. However, non-polar defect complex (V{sub O}··–Cu{sup ‴}{sub Nb}–V{sub O}··)· caused a lattice shrinkage and the observed square shaped P–E loops in KNNC ceramics under high doping levels (x > 1%).

36 MATERIALS SCIENCE↗

Thermodynamic studies on lithium ferrites

Thermodynamic studies on ternary oxides of Li-Fe-O systems were carried out using differential scanning calorimetry, Knudsen effusion mass spectrometry, and solid-state electrochemical technique based on fluoride electrolyte. Heat capacities of LiFe{sub 5}O{sub 8}(s) and LiFeO{sub 2}(s) were determined in the temperature range 127-861 K using differential scanning calorimetry. Gibbs energies of formation of LiFe{sub 5}O{sub 8}(s) and LiFeO{sub 2}(s) were determined using Knudsen effusion mass spectrometry and solid-state galvanic cell technique. The combined least squares fits can be represented as {Delta}{sub f}G{sub m}{sup o}(LiFe{sub 5}O{sub 8},s,T)/kJ mol{sup -1} ({+-}6)=-2341+0.6764(T/K) (588{<=}T/K{<=}971) {Delta}{sub f}G{sub m}{sup o}(LiFeO{sub 2},s,T)/kJ mol{sup -1} ({+-}3)=-708+0.1656(T/K) (569{<=}T/K{<=}1021) The temperature independent term of the above equations represents {Delta}{sub f}H{sup o}{sub m}(T{sub av}) and temperature dependent term represents negative change in entropy of the respective compounds. Thermodynamic analysis shows that LiFe{sub 5}O{sub 8}(s) is more stable compared to LiFeO{sub 2}(s). -- Graphical abstract: Comparison of {Delta}{sub f}G{sub m}{sup o}(T) of lithium ferrites determined using different techniques. Display Omitted Highlights: {yields} Thermodynamic studies on Li-Fe-O system using DSC, KEQMS and galvanic cell. {yields} Heat capacities of LiFe{sub 5}O{sub 8}(s) and LiFeO{sub 2}(s) were determined using DSC 127-861 K. {yields} {Delta}{sub f}G{sup o}{sub m} of these compounds were determined and compared. {yields} Thermodynamic tables for LiFe{sub 5}O{sub 8}(s) and LiFeO{sub 2}(s) were constructed.

36 MATERIALS SCIENCE↗

Stable isotope analysis using tunable diode laser spectroscopy

Ratios of C-12/C-13 in CO2 have been measured using a tunable diode laser (TDL) spectrometer to an accuracy of better than 0.4 percent. These results were made possible by the use of state-of-the-art high-temperature TDLs, an etalon and wavenumber calibration technique, high-speed assembly language controlled data acquisition, and the ratioing of absorbances from simultaneously acquired sample and reference data scans. The dual beam spectrometer that is employed uses the sweep integration technique in a spectral region where adjacent spectral lines are of approximately equal absorbance at the expected isotopic abundances.

Becker, Joseph F.↗

Technical Note: Radiological properties of tissue surrogates used in a multimodality deformable pelvic phantom for MR-guided radiotherapy

Purpose: Phantom surrogates were developed to allow multimodal [computed tomography (CT), magnetic resonance imaging (MRI), and teletherapy] and anthropomorphic tissue simulation as well as materials and methods to construct deformable organ shapes and anthropomorphic bone models. Methods: Agarose gels of variable concentrations and loadings were investigated to simulate various soft tissue types. Oils, fats, and Vaseline were investigated as surrogates for adipose tissue and bone marrow. Anthropomorphic shapes of bone and organs were realized using 3D-printing techniques based on segmentations of patient CT-scans. All materials were characterized in dual energy CT and MRI to adapt CT numbers, electron density, effective atomic number, as well as T1- and T2-relaxation times to patient and literature values. Results: Soft tissue simulation could be achieved with agarose gels in combination with a gadolinium-based contrast agent and NaF to simulate muscle, prostate, and tumor tissues. Vegetable oils were shown to be a good representation for adipose tissue in all modalities. Inner bone was realized using a mixture of Vaseline and K{sub 2}HPO{sub 4}, resulting in both a fatty bone marrow signal in MRI and inhomogeneous areas of low and high attenuation in CT. The high attenuation of outer bone was additionally adapted by applying gypsum bandages to the 3D-printed hollow bone case with values up to 1200 HU. Deformable hollow organs were manufactured using silicone. Signal loss in the MR images based on the conductivity of the gels needs to be further investigated. Conclusions: The presented surrogates and techniques allow the customized construction of multimodality, anthropomorphic, and deformable phantoms as exemplarily shown for a pelvic phantom, which is intended to study adaptive treatment scenarios in MR-guided radiation therapy.

61 RADIATION PROTECTION AND DOSIMETRY↗

Key Role of M.G. Nakhodkin’s Insight and Inspiration in Development of UHV STM-Related Techniques and Methods

In this contribution I briefly describe my joint efforts and experiences with M.G. Nakhodkin in the field of scanning tunneling microscopy (STM) including a construction of the home-built microscopes, application of this technique in various scientific endevours, as well as fruitfull and enlightening discusions. Our co-operation was focused on the novel aspects of STM probes preparation and conditioning, coupling the STM junction with laser irradiation, STM-based nanolithography, and also on collaboration at the international scale with M.G. Nakhodkin and members of his scientific group.

Environmental Molecular Sciences Laboratory↗

Model electrode structures for studies of electrocatalyst degradation.

Proton exchange membrane fuel cells are being extensively studied as power sources because of their technological advantages such as high energy efficiency and environmental friendliness. The most effective catalyst in these systems consists of nanoparticles of Pt or Pt-based alloys on carbon supports. Understanding the role of the nanoparticle size and structure on the catalytic activity and degradation is needed to optimize the fuel cell performance and reduce the noble metal loading. One of the more significant causes of fuel cell performance degradation is the cathode catalyst deactivation. There are four mechanisms considered relevant to the loss of electrochemically active surface area of Pt in the fuel cell electrodes that contribute to cathode catalyst degradation including: catalyst particle sintering such as Ostwald ripening, migration and coalescence, carbon corrosion and catalyst dissolution. Most approaches to study this catalyst degradation utilize membrane electrode assemblies (MEAs), which results in a complex system where it is difficult to deconvolute the effects of the metal nanoparticles. Our research addresses catalyst degradation by taking a fundamental approach to study electrocatalyst using model supports. Nanostructured particle arrays are engineered directly onto planar glassy carbon electrodes. These model electrocatalyst structures are applied to electrochemical activity measurements using a rotating disk electrode and surface characterization by scanning electron microscopy. Sample transfer between these measurement techniques enables examination of the same catalyst area before and after electrochemical cycling. This is useful to probe relationships between electrochemical activity and catalyst structure such as particle size and spacing. These model systems are applied to accelerated aging studies of activity degradation. We will present our work demonstrating the mechanistic aspects of catalyst degradation using this simplified geometric system. The active surface area loss observed in repeated cyclic voltammetry is explained through characterization and imaging of the same RDE electrode structures throughout the aging process.

30 DIRECT ENERGY CONVERSION↗

Preparation of LiNi{sub 0.5}Mn{sub 1.5}O{sub 4} for Lithium Batteries Via Solid-State Redox Method using Nitrate and Acetate Based Reactants

LiNi{sub 0.5}Mn{sub 1.5}O{sub 4} is a potential cathode material for 5 V batteries. This material was prepared by the solid-state redox method using nitrate and acetate based reactants. The precursor material was obtained when the mixture reactants was heated at 500 deg. C for 10 hours and calcined at different temperatures in the range between 650 and 950 deg. C for 12 hours. The structures of the synthesized materials were verified with X- ray diffraction (XRD) measurement and Scanning Electron Microscope (SEM). The charge-discharge technique was determined using Solartron 1470. As calcination temperature increases, the well-ordered crystal growth oriented to [1 1 1] direction shows a clear octahedral morphology, which is the characteristic of the typical cubic spinel. The Li/LiNi{sub 0.5}Mn{sub 1.5}O{sub 4} prepared from acetate based reactants calcined at 750 deg. C for 12 h delivered the discharge capacity of 140 mAh/g.

36 MATERIALS SCIENCE↗