Numerical investigation of vortex tubes with extended vortex chambers

Ranque–Hilsch vortex tubes are often utilized to produce cooling when a compressed air source is readily available. In comparison with traditional cooling technologies, vortex-tube devices are much simpler, since they do not have moving parts. However, their thermal efficiencies are also lower, so they are used primarily for industrial spot cooling. Several options to modify and improve vortex tube performance exist. While a lot of previous research efforts addressed optimization of the inlet and outlet components, the main tube variations have not been thoroughly explored beyond simple tapered tubes. In this paper we numerically investigate augmenting vortex tubes with cyclonic-type extensions of the vortex chambers. The computational fluid dynamics software STAR-CCM+ was utilized to simulate a typical counter-flow vortex tube operating with air. The numerical approach was validated via comparison to experimental studies available in the literature. A reasonably efficient high-capacity vortex tube design was parametrically analyzed. This setup and its several modifications were numerically modeled under selected external conditions. The configuration with an intermediate-size vortex chamber extension demonstrated the highest performance among the studied setups. This variant of the vortex tube was also predicted to perform better than the original system by about 15% in a range of cold-flow fractions.

08 HYDROGEN↗

Adverse Events Involving Radiation Oncology Medical Devices: Comprehensive Analysis of US Food and Drug Administration Data, 1991 to 2015

Purpose: Radiation oncology relies on rapidly evolving technology and highly complex processes. The US Food and Drug Administration collects reports of adverse events related to medical devices. We sought to characterize all events involving radiation oncology devices (RODs) from the US Food and Drug Administration's postmarket surveillance Manufacturer and User Facility Device Experience (MAUDE) database, comparing these with non–radiation oncology devices. Methods and Materials: MAUDE data on RODs from 1991 to 2015 were sorted into 4 product categories (external beam, brachytherapy, planning systems, and simulation systems) and 5 device problem categories (software, mechanical, electrical, user error, and dose delivery impact). Outcomes included whether the device was evaluated by the manufacturer, adverse event type, remedial action, problem code, device age, and time since 510(k) approval. Descriptive statistics were performed with linear regression of time-series data. Results for RODs were compared with those for other devices by the Pearson χ{sup 2} test for categorical data and 2-sample Kolmogorov-Smirnov test for distributions. Results: There were 4234 ROD and 4,985,698 other device adverse event reports. Adverse event reports increased over time, and events involving RODs peaked in 2011. Most ROD reports involved external beam therapy (50.8%), followed by brachytherapy (24.9%) and treatment planning systems (21.6%). The top problem types were software (30.4%), mechanical (20.9%), and user error (20.4%). RODs differed significantly from other devices in each outcome (P<.001). RODs were more likely to be evaluated by the manufacturer after an event (46.9% vs 33.0%) but less likely to be recalled (10.5% vs 37.9%) (P<.001). Device age and time since 510(k) approval were shorter among RODs (P<.001). Conclusions: Compared with other devices, RODs may experience adverse events sooner after manufacture and market approval. Close postmarket surveillance, improved software design, and manufacturer–user training may help mitigate these events.

07 ISOTOPE AND RADIATION SOURCES↗

Modeling extreme ultraviolet suppression of electrostatic analyzers

In addition to analyzing energy-per-charge ratios of incident ions, electrostatic analyzers (ESAs) for spaceborne time-of-flight mass spectrometers must also protect detectors from extreme ultraviolet (EUV) photons from the Sun. The required suppression rate often exceeds 1:10{sup 7} and is generally established in tests upon instrument design and integration. This paper describes a novel technique to model the EUV suppression of ESAs using photon ray tracing integrated into SIMION, the most commonly used ion optics design software for such instruments. The paper compares simulation results with measurements taken from the ESA of the Mass instrument flying onboard the Wind spacecraft. This novel technique enables an active inclusion of EUV suppression requirements in the ESA design process. Furthermore, the simulation results also motivate design rules for such instruments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Verification of Floating Offshore Wind Linearization Functionality in OpenFAST

The wind engineering community relies on multiphysics engineering software to run nonlinear time-domain simulations, e.g., for design standards-based loads analysis. Although most physics involved in wind energy are nonlinear, linearization of the underlying nonlinear system equations is often advantageous to understand the system properties and exploit well-established methods and tools for analyzing linear systems. Previous work in this area has focused on the development of the new linearization functionality of the open-source engineering tool OpenFAST for floating offshore wind turbines, as well as the concepts and mathematical background needed to understand and apply it correctly. This paper focuses on the verification of this new linearization functionality, which is carried out by comparing results to previous stable versions of FAST. A nonlinear time-domain simulation for a floating offshore platform is also compared to the time-domain response of the linearized state-space model. The linearized results show good alignment between OpenFAST and previous versions of FAST, as well as with the time-domain simulations, thereby showing the accuracy of the new features in OpenFAST.

17 WIND ENERGY↗

Fidelity Comparison of Time-Bin and Fock State Encoding in Hybrid Quantum Systems Under Channel and Transduction Effects

Future quantum networks are expected to integrate a heterogeneous combination of quantum systems, owing to the diverse advantages offered by different physical platforms in terms of scalability, coherence times, and interfacing capabilities. Within the context of this emerging quantum communication paradigm, this paper presents an analytical comparison of two photonic encoding schemes—time-bin and Fock state (single rail)—in hybrid quantum systems where flying qubits are entangled with stationary matter qubits. We evaluate their resilience against fiber channel and quantum transduction effects by calculating the fidelity of the final states relative to their ideal forms. Employing the characteristic function approach, we derive analytical fidelity expressions and investigate their dependence on parameters such as transmissivity, noise levels, fiber length, and source generation success probability. Additionally, we simulate the scenario with a dedicated QuTiP software implementation to verify the validity of the theoretical models. Our findings reveal that due to its inherent single-mode structure, the Fock state encoding consistently outperforms time-bin encoding in fidelity, as this structure significantly minimizes susceptibility to losses compared to the two-mode nature of the time-bin scheme. This analysis offers valuable insights for future hybrid quantum communication and information processing applications.

Fiorini, Francesco [Pisa U.]↗

Coupled Electro-Thermal Analysis of Permanent Magnet Synchronous Motor for Electric Vehicles

Permanent magnet synchronous motors (PMSM) are extensively used in electric vehicles. However, high internal heat generation and inefficient heat dissipation often limit the operational reliability, and longevity of the PMSM. Therefore, proper quantification of heat generation in electric motor and advanced embedded motor cooling techniques remain topics of immense interest. In order to accurately predict electro-magnetic performance, i.e., efficiency, component-wise heat losses and the corresponding temperature distribution of a jacket cooled machine, this paper presents a two-way iteratively coupled electro-thermal modeling framework. Finite element based software Motor-CAD has been utilized for electro-magnetic performance calculation of BMW i3 PMSM. Finite volume based computational fluid dynamics/heat transfer (CFD/HT) software ANSYS® FLUENT® has been employed to simulate the temperature distribution of the PMSM, using the electro-magnetic losses as heat input. Computed heat losses, stator, winding, rotor, and magnet temperatures are utilized as coupling parameters between the electro-magnetic and thermal models. A conventional one-way coupling algorithm has also been developed and compared to the newly proposed two-way coupling algorithm. Numerical results confirm that at high current density, one-way coupling algorithm significantly over-predicts the motor temperature compared to the two-way algorithm. A comprehensive analysis has been carried out to characterize the influences of current density, speed, and forced convection heat transfer coefficient on the heat losses, overall efficiency, and maximum temperature of the PMSM. Lastly, an efficiency map has been interpreted from the coupled electro-magnetic simulation.

42 ENGINEERING↗

A domain-specific compiler for a parallel multiresolution adaptive numerical simulation environment

This paper describes the design and implementation of a layered domain-specific compiler to support MADNESS---Multiresolution ADaptive Numerical Environment for Scientific Simulation. MADNESS is a high-level software environment for the solution of integral and differential equations in many dimensions, using adaptive and fast harmonic analysis methods with guaranteed precision. MADNESS uses k-d trees to represent spatial functions and implements operators like addition, multiplication, differentiation, and integration on the numerical representation of functions. The MADNESS runtime system provides global namespace support and a task-based execution model including futures. MADNESS is currently deployed on massively parallel supercomputers and has enabled many science advances. Due to the highly irregular and statically unpredictable structure of the k-d trees representing the spatial functions encountered in MADNESS applications, only purely runtime approaches to optimization have previously been implemented in the MADNESS framework. This paper describes a layered domain-specific compiler developed to address some performance bottlenecks in MADNESS. The newly developed static compile-time optimizations, in conjunction with the MADNESS runtime support, enable significant performance improvement for the MADNESS framework.

Rajbhandari, Samyam↗

Full-System Linearization for Floating Offshore Wind Turbines in OpenFAST

The wind engineering community relies on multiphysics engineering software to run nonlinear time-domain simulations (e.g., for design-standards-based loads analysis). Although most physics involved in wind energy are nonlinear, linearization of the underlying nonlinear system equations is often advantageous to understand the system properties and exploit well-established methods and tools for analyzing linear systems. This paper presents the development of the new linearization functionality of the open-source engineering tool OpenFAST for floating offshore wind turbines, as well as the concepts and mathematical background needed to understand and apply it.

17 WIND ENERGY↗

Effects of breathing variation on gating window internal target volume in respiratory gated radiation therapy

Purpose: To investigate the effects of breathing variation on gating window internal target volume (ITV{sub GW}) in respiratory gated radiation therapy. Method and Materials: Two-dimensional dynamic MRI (dMRI) of lung motion was acquired in ten volunteers and eight lung cancer patients. Resorted dMRI using 4DCT acquisition method (RedCAM) was generated for selected subjects by simulating the image rebinning process. A dynamic software generated phantom (dSGP) was created by moving a solid circle (to mimic the ''tumor'') with dMRI-determined motion trajectories. The gating window internal target area (ITA{sub GW}, 2D counterpart of ITV{sub GW}) was determined from both RedCAM and dSGP/dMRI. Its area (A), major axis (L1), minor axis (L2), and similarity (S) were calculated and compared. Results: In the phantom study of 3 cm tumor, measurements of the ITA{sub GW} from dSGP (A=10.0{+-}1.3 cm{sup 2}, L1=3.8{+-}0.4 cm, and L2=3.3{+-}0.1 cm) are significantly (p<0.001) greater than those from RedCAM (A=8.5{+-}0.7 cm{sup 2}, L1=3.5{+-}0.2 cm, and L2=3.1{+-}0.1 cm). Similarly, the differences are significantly greater (p<0.001) for the 1 cm tumor (A=1.9{+-}0.5 cm{sup 2}, L1=1.9{+-}0.4 cm, and L2=1.3{+-}0.1 cm in dSGP; A=1.3{+-}0.1 cm{sup 2}, L1=1.5{+-}0.2 cm, and L2=1.1{+-}0.1 cm in RedCAM). In patient studies, measurements of the ITA{sub GW} from dMRI (A=15.5{+-}8.2 cm{sup 2}, L1=5.0{+-}1.1 cm, and L2=3.8{+-}1.2 cm) are also significantly greater (p<0.05) than those from RedCAM (A=13.2{+-}8.5 cm{sup 2}, L1=4.3{+-}1.4 cm, and L2=3.7{+-}1.2 cm). Similarities were 0.9{+-}0.1, 0.8{+-}0.1, and 0.8{+-}0.1 in the 3 cm tumor phantom, 1 cm tumor phantom, and patient studies, respectively. Conclusion: ITV{sub GW} can be underestimated by 4DCT due to breathing variations. An additional margin may be needed to account for this potential error in generating a PTV{sub GW}. Cautions need to be taken when generating ITV{sub GW} from 4DCT in respiratory gated radiation therapy, especially for small tumors (<3 cm) with a large motion range (>1 cm).

60 APPLIED LIFE SCIENCES↗

TU-F-CAMPUS-I-01: Investigation of the Effective Dose From Bolus Tracking Acquisitions at Different Anatomical Locations in the Chest for CT

Purpose: Stationary table acquisitions (Bolus tracking) in X-ray Computed Tomography (CT) can Result in dose length products (DLP) comparable to spiral scans. It is today unclear whether or not the effective dose (E) for Bolus Tracking can be approximated using target region specific conversion factors (E/DLP). The purpose of this study was to investigate how E depends on the anatomical location of the Bolus Tracking in relation to Chest CT scans with the same DLP. Methods: Effective doses were approximated for the ICRP 110 adult Reference Male (AM) and adult Reference Female (FM) computational voxel phantoms using software for CT dose approximations (pre-simulated MC data). The effective dose was first approximated for a Chest CT scan using spiral technique and a CTDIvol (32 cm) of 6 mGy. The effective dose from the spiral scan was then compared to E approximated for contiguous Bolus Tracking acquisitions (1 cm separation), with a total collimation of 1 cm, over different locations of the chest of the voxel phantoms. The number of rotations used for the Bolus Tracking acquisitions was adjusted to yield the same DLP (32 cm) as the spiral scan. Results: Depending on the anatomical location of the Bolus Tracking, E ranged by factors of 1.3 to 6.8 for the AM phantom and 1.4 to 3.3 for the AF phantom, compared to the effective dose of the spiral scans. The greatest E for the Bolus Tracking acquisitions was observed for anatomical locations coinciding with breast tissue. This can be expected as breast tissue has a high tissue weighting factor in the calculation of E. Conclusion: For Chest CT scans, the effective dose from Bolus Tracking is highly dependent on the anatomical location where the scan is administered and will not always accurately be represented using target region specific conversion factors.

60 APPLIED LIFE SCIENCES↗

SU-F-I-27: Measurement of SAR and Temperature Elevation During MRI Scans

Purpose: The poor reliability and repeatability of the manufacturer-reported SAR values on clinical MRI systems have been acknowledged. The purpose of this study is to not only measure SAR values, but also RF-induced temperature elevation at 1.5 and 3T MRI systems. Methods: SAR measurement experiment was performed at 1.5 and 3T. Three MRI RF sequences (T1w TSE, T1w inversion recovery, and T2w TSE) with imaging parameters were selected. A hydroxyl-ethylcelluose (HEC) gelled saline phantom mimicking human body tissue was made. Human torso phantom were constructed, based on Korean adult standard anthropometric reference data (Fig.1). FDTD method was utilized to calculate the SAR distribution using Sim4Life software. Based on the results of the simulation, 4 electrical field (E-field) sensors were located inside the phantom. 55 Fiber Bragg Grating (FBG) temperature sensors (27 sensors in upper and lower cover lids, and one sensor located in the center as a reference) were located inside the phantom to measure temperature change during MRI scan (Fig.2). Results: Simulation shows that SAR value is 0.4 W/kg in the periphery and 0.001 W/kg in the center (Fig.2). One 1.5T and one of two 3T MRI systems represent that the measured SAR values were lower than MRI scanner-reported SAR values. However, the other 3T MRI scanner shows that the averaged SAR values measured by probe 2, 3, and 4 are 6.83, 7.59, and 6.01 W/kg, compared to MRI scanner-reported whole body SAR value (<1.5 W/kg) for T2w TSE (Table 1). The temperature elevation measured by FBG sensors is 5.2°C in the lateral shoulder, 5.1°C in the underarm, 4.7°C in the anterior axilla, 4.8°C in the posterior axilla, and 4.8°C in the lateral waist for T2w TSE (Fig.3). Conclusion: It is essential to assess the safety of MRI system for patient by measuring accurate SAR deposited in the body during clinical MRI.

60 APPLIED LIFE SCIENCES↗

MO-FG-CAMPUS-IeP3-01: Evaluation of Specific Absorption Rate and Temperature Increase Induced by Artificial Medical Implants During MRI Scan

Purpose: Heating of patients or burning of biological tissues around medical implants by RF power during MRI scan is a significant patient safety concern. The purpose of this study is to not only measure SAR values, but also RF-induced temperature elevation due to artificial hip joints during MRI scans. Methods: SAR measurement experiment was performed on three discrete manufacturers at 1.5 and 3T. Three MRI RF sequences (T1w TSE, T2w inversion recovery, and T2w TSE) with imaging parameters were selected. A gelled saline phantom mimicking human body tissue was made (Fig.1). FDTD method was utilized to calculate the SAR distribution using Sim4Life software. Based on the results of the simulation, 4 electrical field (E-field) sensors were located around two artificial hip joints inside the phantom. 56 Fiber Bragg Grating (FBG) temperature sensors (28 sensors on each artificial hip joint) were located on both left and right artificial hip joints to measure temperature change during MRI scan (Fig.1). Both E-field and FBG temperature sensors were calibrated with traceability at Korea Research Institute of Standards and Science (KRISS). Results: Simulation shows that high SAR values occur in the head and tail of the implanted artificial hip joints (Fig.1 lower right). 3T MRI scanner shows that the local averaged-SAR values measured by probe 1, 2, and 3 are 2.30, 2.77, and 1.68 W/kg, compared to MRI scanner-reported whole body SAR value (≤1.5 W/kg) for T1w TSE and T2w-IR (Table 1). The maximum temperature elevation measured by FBG sensors is 1.49°C at 1.5 T, 2.0°C at 3 T, and 2.56°C at 3 T for T1w TSE, respectively (Table 2). Conclusion: It is essential to assess the safety of MRI system for patient with medical implant by measuring not only accurate SAR deposited in the body, but also temperature elevation due to the deposited SAR during clinical MRI.

60 APPLIED LIFE SCIENCES↗

CryoModule On Chip (CMOC) v1.0

The software, titled Cryomodule-On-Chip (CMOC), simulates a cryomodule used for low-level RF acceleration in superconducting cavities. The model includes a state-space model of the accelerating fields inside the cavity, the mechanical resonances inside a cryomodule, and their interactions.

Pareja, CarlosSerrano↗

HPCGraph v. 0.1

Graphs occur in several places in real world from road networks, social networks and scientific simulations. HPC Graph is a graph analysis software to analyze the properties such as connectivity, communities etc in extreme scale graphs.

Slota, George↗

Learning Planar Ising Models Software

Learning Planar Ising Models is a software package written in Matlab for learning relationships among variable in a dataset using graphical models. The software package implements a generally-applicable algorithm for learning planar Ising models from any multivariate dataset. The code provides an algorithm for learning the best planar Ising model to approximate an arbitrary collection of binary random variables (possibly from sample data). Given the set of all pairwise correlations among variables, we select a planar graph and optimal planar Ising model defined on this graph to best approximate that set of correlations. The software includes demonstrations of the algorithm in simulations and for applications on publicly available datasets. Details of the algorithm, demonstration simulations, and applications are given in Johnson, et al; 2016. Reference: Johnson, J. K., Oyen, D., Chertkov, M., and Netrapalli, P. (2016). Learning planar Ising models. Journal of Machine Learning Research.

Oyen, Diane↗

Flash-X

Flash-X is a highly composable multiphysics software system that can be used to simulate physical phenomena in several scientific domains. It is derived from FLASH, which has been a community code for several communities over the last 20 years. The Flash-X architecture has been redesigned to be compatible with increasingly heterogeneous hardware platforms. A part of the redesign is a utilizing a newly designed performance portability layer that is language agnostic.

Dubey, Anshu [Argonne National Laboratory (ANL), A↗

Code for Experiment in Publication “Sensitivity Analysis in the Presence of Intrinsic Stochasticity for Discrete Fracture Network Simulations”

Following the Open Research requirements for AGU journals, we must release the code used to perform the experiment described in our recent publication, posted at (https://arxiv.org/abs/2312.04722). This code fits a joint emulator to data from a Discrete Fracture Network (DFN) simulation, performed using the open-source software DFNworks (https://dfnworks.lanl.gov/). All code to be released implements existing methods; there are no novel algorithms nor any major innovations to existing software.

Murph, Alexander↗

Code for Experiment in Publication “Determining the dominant factors for carbon-1 mineralization in three-dimensional fracture networks”

We plan to release the code used to perform the experiment described in our recent publication, entitled “Determining the dominant factors for carbon-1 mineralization in three-dimensional fracture networks.” This code fits a joint emulator to data from several Discrete Fracture Network (DFN) simulations, performed using the open-source software DFNworks (https://dfnworks.lanl.gov/). All code to be released implements existing methods; there are no novel algorithms nor any major innovations to existing software.

Murph, Alexander↗