Search NASA⌕ Search

SEARCH · Search NASA

Results for “cavity methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,765 records · Page 98

Development of generalized block correction procedures for the solution of discretized Navier-Stokes equations

Effort is directed towards developing a solution method which combines advantages of both the iterative and the direct methods. It involves iterative solution on the fine grid, convergence of which is enhanced by a direct solution for correction quantities on a coarse grid. The proposed block correction procedure was applied to compute recirculating flow in a driven cavity.

Kelkar, Kanchan M.↗

Hopf bifurcation in the driven cavity

Incompressible two dimensional calculations are reported for the impulsively started lid driven cavity with aspect ratio two. The algorithm is based on the time dependent streamfunction equation, with a Crank-Nicolson differencing scheme for the diffusion terms, and with an Adams-Bashforth scheme for the convection terms. A multigrid method is used to solve the linear implicit equations at each time step. Periodic asymptotic solutions have been found for Re = 10000 and for Re = 5000. The Re = 5000 results are validated by grid refinement calculations. The solutions are shown to be precisely periodic, and care is taken to demonstrate that asymptotic states were reached. A discussion is included about the indicators that are used to show that an asymptotic state was reached, and to show that the asymptotic state is indeed periodic.

Goodrich, John W.↗

MEMS Direct Chip Attach Packaging Methodologies and Apparatuses for Harsh Environments

Methods of bulk manufacturing high temperature sensor subassembly packages are disclosed and claimed. Sensors are sandwiched between a top cover and a bottom cover so as to enable the peripheries of the top covers, sensors and bottom covers to be sealed and bound securely together are disclosed and claimed. Sensors are placed on the bottom covers leaving the periphery of the bottom cover exposed. Likewise, top covers are placed on the sensors leaving the periphery of the sensor exposed. Individual sensor sub-assemblies are inserted into final packaging elements which are also disclosed and claimed. Methods of directly attaching wires or pins to contact pads on the sensors are disclosed and claimed. Sensors, such as pressure sensors and accelerometers, and headers made out of silicon carbide and aluminum nitride are disclosed and claimed. Reference cavities are formed in some embodiments disclosed and claimed herein where top covers are not employed.

Okojie, Robert S.↗

Parallel Adaptive High-Order CFD Simulations Characterizing Cavity Acoustics for the Complete SOFIA Aircraft

This paper presents one-of-a-kind MPI-parallel computational fluid dynamics simulations for the Stratospheric Observatory for Infrared Astronomy (SOFIA). SOFIA is an airborne, 2.5-meter infrared telescope mounted in an open cavity in the aft of a Boeing 747SP. These simulations focus on how the unsteady flow field inside and over the cavity interferes with the optical path and mounting of the telescope. A temporally fourth-order Runge-Kutta, and spatially fifth-order WENO-5Z scheme was used to perform implicit large eddy simulations. An immersed boundary method provides automated gridding for complex geometries and natural coupling to a block-structured Cartesian adaptive mesh refinement framework. Strong scaling studies using NASA's Pleiades supercomputer with up to 32,000 cores and 4 billion cells shows excellent scaling. Dynamic load balancing based on execution time on individual AMR blocks addresses irregularities caused by the highly complex geometry. Limits to scaling beyond 32K cores are identified, and targeted code optimizations are discussed.

Acoustics↗

Emittance and Phase Space Exchange for Advanced Beam Manipulation and Diagnostics

Alternative chicane-type beam lines are proposed for exact emittance exchange between transverse phase space (x,x') and longitudinal phase space (z,{delta}), where x is the transverse position, x' is the transverse divergence, and z and {delta} are relative longitudinal position and energy deviation with respect to the reference particle. Methods to achieve exact phase space exchanges, i.e., mapping x to z, x' to {delta}, z to x, and {delta} to x', are suggested. Schemes to mitigate and completely compensate for the thick-lens effect of the transverse cavity on emittance exchange are studied. Some applications of the phase space exchange for advanced beam manipulation and diagnostics are discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Material fabrication using acoustic radiation forces

Apparatus and methods for using acoustic radiation forces to order particles suspended in a host liquid are described. The particles may range in size from nanometers to millimeters, and may have any shape. The suspension is placed in an acoustic resonator cavity, and acoustical energy is supplied thereto using acoustic transducers. The resulting pattern may be fixed by using a solidifiable host liquid, forming thereby a solid material. Patterns may be quickly generated; typical times ranging from a few seconds to a few minutes. In a one-dimensional arrangement, parallel layers of particles are formed. With two and three dimensional transducer arrangements, more complex particle configurations are possible since different standing-wave patterns may be generated in the resonator. Fabrication of periodic structures, such as metamaterials, having periods tunable by varying the frequency of the acoustic waves, on surfaces or in bulk volume using acoustic radiation forces, provides great flexibility in the creation of new materials. Periodicities may range from millimeters to sub-micron distances, covering a large portion of the range for optical and acoustical metamaterials.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Material fabrication using acoustic radiation forces

Apparatus and methods for using acoustic radiation forces to order particles suspended in a host liquid are described. The particles may range in size from nanometers to millimeters, and may have any shape. The suspension is placed in an acoustic resonator cavity, and acoustical energy is supplied thereto using acoustic transducers. The resulting pattern may be fixed by using a solidifiable host liquid, forming thereby a solid material. Patterns may be quickly generated; typical times ranging from a few seconds to a few minutes. In a one-dimensional arrangement, parallel layers of particles are formed. With two and three dimensional transducer arrangements, more complex particle configurations are possible since different standing-wave patterns may be generated in the resonator. Fabrication of periodic structures, such as metamaterials, having periods tunable by varying the frequency of the acoustic waves, on surfaces or in bulk volume using acoustic radiation forces, provides great flexibility in the creation of new materials. Periodicities may range from millimeters to sub-micron distances, covering a large portion of the range for optical and acoustical metamaterials.

36 MATERIALS SCIENCE↗

Charge generating devices and methods of making and use thereof

Provided herein are charge generating devices and methods of making and use thereof. The charge generating devices comprise a substrate having a top surface; a plurality of spaced-apart three-dimensional elements disposed on the top surface of the substrate; and a plurality of cavities formed by the plurality of spaced-apart three-dimensional elements, the plurality of cavities being the area between the plurality of spaced-apart three-dimensional elements. The charge generating devices can further comprise a radioactive layer disposed on at least a portion of the plurality of spaced-apart three-dimensional elements and the top surface such that the plurality of cavities and the top surface are substantially coated by the radioactive layer. In some examples, the charge generating devices can comprise a radiation material and/or a scintillating material disposed within at least a portion of the plurality of cavities.

Cao, Lei↗

Insert system for an airfoil and method of installing same

An insert system for an airfoil plenum includes a first insert and a second insert that include a plurality of impingement openings defined therein. The first insert includes a forward-facing inlet opening. The second insert includes a neck portion having a radial-facing inlet opening, an aft opening, and a cavity in flow communication between the radial-facing inlet opening and the aft opening. The second insert is sized for insertion into the plenum radially through a plenum inlet such that the neck portion is positioned in the plenum inlet. The first insert is sized for insertion into the second insert radially through the radial-facing inlet opening. When the neck portion is positioned in the plenum inlet, the first insert is moveable aftward through the aft opening into an installed position such that the forward-facing inlet opening opens into the cavity.

Berry, Jonathan Dwight↗

System and method for laser system having non-planar thin disc gain media

The present disclosure relates to a laser system. The laser system may have at least non-flat gain media disc. At least one pump source may be configured to generate a beam that pumps the non-flat gain media disc. A laser cavity may be formed by the pump source and the non-flat gain media disc. An output coupler may be included for receiving and directing the output beam toward an external component.

Dawson, Jay W.↗

A Survey of Pressure Vessel Code Compliance for Superconducting RF Cryomodules

Superconducting radio frequency (SRF) cavities made from niobium and cooled with liquid helium are becoming key components of many particle accelerators. The helium vessels surrounding the RF cavities, portions of the niobium cavities themselves, and also possibly the vacuum vessels containing these assemblies, generally fall under the scope of local and national pressure vessel codes. In the U.S., Department of Energy rules require national laboratories to follow national consensus pressure vessel standards or to show ''a level of safety greater than or equal to'' that of the applicable standard. Thus, while used for its superconducting properties, niobium ends up being treated as a low-temperature pressure vessel material. Niobium material is not a code listed material and therefore requires the designer to understand the mechanical properties for material used in each pressure vessel fabrication; compliance with pressure vessel codes therefore becomes a problem. This report summarizes the approaches that various institutions have taken in order to bring superconducting RF cryomodules into compliance with pressure vessel codes. In Japan, Germany, and the U.S., institutions building superconducting RF cavities integrated in helium vessels or procuring them from vendors have had to deal with pressure vessel requirements being applied to SRF vessels, including the niobium and niobium-titanium components of the vessels. While niobium is not an approved pressure vessel material, data from tests of material samples provide information to set allowable stresses. By means of procedures which include adherence to code welding procedures, maintaining material and fabrication records, and detailed analyses of peak stresses in the vessels, or treatment of the vacuum vessel as the pressure boundary, research laboratories around the world have found methods to demonstrate and document a level of safety equivalent to the applicable pressure vessel codes.

43 PARTICLE ACCELERATORS↗

Novel high-gain, improved-bandwidth, finned-ladder V-band Traveling-Wave Tube slow-wave circuit design

The V-band frequency range of 59-64 GHz is a region of the millimeter-wave spectrum that has been designated for inter-satellite communications. As a first effort to develop a high-efficiency V-band Traveling-Wave Tube (TWT), variations on a ring-plane slow-wave circuit were computationally investigated to develop an alternative to the more conventional ferruled coupled-cavity circuit. The ring-plane circuit was chosen because of its high interaction impedance, large beam aperture, and excellent thermal dissipation properties. Despite these advantages, however, low bandwidth and high voltage requirements have, until now, prevented its acceptance outside the laboratory. In this paper, the three-dimensional electrodynamic simulation code MAFIA (solution of MAxwell's Equation by the Finite-Integration-Algorithm) is used to investigate methods of increasing the bandwidth and lowering the operating voltage of the ring-plane circuit. Calculations of frequency-phase dispersion, beam on-axis interaction impedance, attenuation and small-signal gain per wavelength were performed for various geometric variations and loading distributions of the ring-plane TWT slow-wave circuit. Based on the results of the variations, a circuit termed the finned-ladder TWT slow-wave circuit was designed and is compared here to the scaled prototype ring-plane and a conventional ferruled coupled-cavity TWT circuit over the V-band frequency range. The simulation results indicate that this circuit has a much higher gain, significantly wider bandwidth, and a much lower voltage requirement than the scaled ring-plane prototype circuit, while retaining its excellent thermal dissipation properties. The finned-ladder circuit has a much larger small-signal gain per wavelength than the ferruled coupled-cavity circuit, but with a moderate sacrifice in bandwidth.

Kory, Carol L.↗

Distributed Bragg reflectors obtained by combining Se and Te compounds: Influence on the luminescence from CdTe quantum dots

We report on the optical properties of structures containing self assembled CdTe quantum dots (QDs) combined with Te and Se based distributed Bragg reflectors either in a half cavity geometry with a relatively broad cavity mode or in a full cavity geometry where the cavity mode is much narrower. We show that for both structures the extraction coefficient of the light emitted from the QDs ensemble is enhanced by more than one order of magnitude with respect to the QDs grown on a ZnTe buffer. However, a single QD line broadening is observed and attributed to an unintentional incorporation of Se in the vicinity of the CdTe QDs. We show that postponing the QDs growth for 24 h after the distributed Bragg reflector deposition allows recovering sharp emission lines from individual QDs. This two step growth method is proven to be efficient also for the structures with CdTe QDs containing a single Mn{sup 2+} ion.

36 MATERIALS SCIENCE↗

SU-F-T-12: Monte Carlo Dosimetry of the 60Co Bebig High Dose Rate Source for Brachytherapy

Purpose: The purpose of this work is to obtain the dosimetry parameters in accordance with the AAPM TG-43U1 formalism with Monte Carlo calculations regarding the BEBIG 60Co high-dose-rate brachytherapy. The geometric design and material details of the source was provided by the manufacturer and was used to define the Monte Carlo geometry. Methods: The dosimetry studies included the calculation of the air kerma strength Sk, collision kerma in water along the transverse axis with an unbounded phantom, dose rate constant and radial dose function. The Monte Carlo code system that was used was EGSnrc with a new cavity code, which is a part of EGS++ that allows calculating the radial dose function around the source. The XCOM photon cross-section library was used. Variance reduction techniques were used to speed up the calculation and to considerably reduce the computer time. To obtain the dose rate distributions of the source in an unbounded liquid water phantom, the source was immersed at the center of a cube phantom of 100 cm3. Results: The obtained dose rate constant for the BEBIG 60Co source was 1.108±0.001 cGyh-1U-1, which is consistent with the values in the literature. The radial dose functions were compared with the values of the consensus data set in the literature, and they are consistent with the published data for this energy range. Conclusion: The dose rate constant is consistent with the results of Granero et al. and Selvam and Bhola within 1%. Dose rate data are compared to GEANT4 and DORZnrc Monte Carlo code. However, the radial dose function is different by up to 10% for the points that are notably near the source on the transversal axis because of the high-energy photons from 60Co, which causes an electronic disequilibrium at the interface between the source capsule and the liquid water for distances up to 1 cm.

60 APPLIED LIFE SCIENCES↗

Extremum seeking for optimal control problems with unknown time-varying systems and unknown objective functions

We consider the problem of optimal feedback control of an unknown, noisy, time-varying, dynamic system that is initialized repeatedly. Examples include a robotic manipulator which must perform the same motion, such as assisting a human, repeatedly and accelerating cavities in particle accelerators which are turned on for a fraction of a second with given initial conditions and vary slowly due to temperature fluctuations. In this paper, we present an approach that applies to systems of practical interest. The method presented here is model independent; does not require knowledge of the objective function; is robust to measurement noise; is applicable for any set of initial conditions; is applicable to simultaneously controlling an arbitrary number of parameters; and may be implemented with a broad range of continuous or discontinuous functions such as sine or square waves. For systems with convex cost functions we prove that our algorithm will produce controllers that approach the minimal cost. For linear systems we reproduce the cost minimizing linear quadratic regulator optimal controller that could have been designed analytically had the system and cost function been known. We demonstrate the effectiveness of the algorithm with simulation studies of noisy and time-varying systems.

42 ENGINEERING↗

Fano resonances based on plasmonic square resonator with high figure of merits and its application in glucose concentrations sensing

A compact plasmonic structure is proposed employing symmetrical metal–insulator-metal (MIM) waveguides coupled to the square resonator for nano-sensing applications, especially for water glucose sensing. Finite difference time domain method is chosen to derivate the output characteristics and magnetic-field distributions. Outcomes illustrate the Fano resonance in the output characteristics can be simply managed by varying the inner and outer lengths and the refractive index of the square cavity. Also, between Fano resonance wavelength and resonator length, a linear behavior exists. These features suggest that physical parameters provide flexibility to propose the structure. Our plasmonic device produces a sensitivity and figure of merit of about 6400 nm/RIU and 1 × 10{sup 4}, respectively. By utilizing the mathematical model for water refractive index, we aim to develop a sensor structure to detect the glucose concentration in water. This designed sensor may discover significant applications in future nanosensing domain.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

MRI Guidance for Accelerated Partial Breast Irradiation in Prone Position: Imaging Protocol Design and Evaluation

Purpose: To design and evaluate a magnetic resonance imaging (MRI) protocol to be incorporated in the simulation process for external beam accelerated partial breast irradiation. Methods and Materials: An imaging protocol was developed based on an existing breast MRI technique with the patient in the prone position on a dedicated coil. Pulse sequences were customized to exploit T1 and T2 contrast mechanisms characteristic of lumpectomy cavities. A three-dimensional image warping algorithm was included to correct for geometric distortions related to nonlinearity of spatially encoding gradients. Respiratory motion, image distortions, and susceptibility artifacts of 3.5-mm titanium surgical clips were examined. Magnetic resonance images of volunteers were acquired repeatedly to analyze residual setup deviations resulting from breast tissue deformation. Results: The customized sequences generated high-resolution magnetic resonance images emphasizing lumpectomy cavity morphology. Respiratory motion was negligible with the subject in the prone position. The gradient-induced nonlinearity was reduced to less than 1 mm in a region 15 cm away from the isocenter of the magnet. Signal-void regions of surgical clips were 4 mm and 8 mm for spin echo and gradient echo images, respectively. Typical residual repositioning errors resulting from breast deformation were estimated to be 3 mm or less. Conclusions: MRI guidance for accelerated partial breast irradiation with the patient in the prone position with adequate contrast, spatial fidelity, and resolution is possible.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Outcomes of Postoperative Simultaneous Modulated Accelerated Radiotherapy for Head-and-Neck Squamous Cell Carcinoma

Purpose: To evaluate the treatment efficacy and toxicity of postoperative simultaneous modulated accelerated radiotherapy (SMART) for patients with head-and-neck squamous cell carcinoma (HNSCC). Methods and Materials: Between February 2003 and September 2008, 51 patients with histologically confirmed HNSCC received postoperative intensity-modulated radiotherapy (N = 33) or helical tomotherapy (N = 18) using SMART after curative surgical resection. The sites included were the oral cavity (OC), oropharynx (OP), larynx, and hypopharynx in 23, 20, 5, and 3 patients, respectively. Results: The median follow-up duration of all patients and surviving patients were 32 (range, 5-78 months) and 39 months (range, 9-77 months), respectively. The 3-year overall survival, cause-specific survival, disease-free survival, locoregional recurrence-free survival (LRRFS), and distant metastasis-free survival (DMFS) in all patients were 71%, 77%, 75%, 85%, and 82%, respectively. Although no significant difference in 3-year LRRFS were found between OC (82%) and OP (82%) carcinomas, the 3-year DMFS was worse in cases of OC (66%) carcinoma compared with OP carcinoma (95%; p = 0.0414). Acute Grade 3 dermatitis, mucositis, and esophagitis occurred in 10%, 10%, and 2% of patients, respectively. At the last follow-up, Grade 3 xerostomia was documented in 10% of the patients. Young age ({<=}40 years) (p < 0.001) and OC carcinoma primary (p = 0.0142) were poor risk factors on univariate analysis for DMFS. Conclusion: Postoperative SMART was observed to be effective and safe in patients with HNSCC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗