Search NASA⌕ Search

SEARCH · Search NASA

Results for “distributed”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,765 records · Page 98

Distribution Feeder-Scale Fast Frequency Response via Optimal Coordination of Net-load Resources Part II: Large-Scale Demonstration

This work is the second of a two-part series in which we develop and experimentally demonstrate a hierarchical control solution for optimally coordinating thousands of deferrable loads and distributed energy resources (DERs) to provide fast frequency response (FFR) from an entire distribution feeder. In Part I, we developed and proved practical algorithms for fast, cost-based optimal dispatch and for determining the optimal amount of headroom to operate solar inverters with to support FFR dispatch while minimizing opportunity cost. Simulation results in Part I demonstrated the advantages of the hierarchical dispatch approach in being able to maintain fast solution times needed for FFR even when the problem size increases. In Part II, we implement the algorithms developed in Part I in a novel, large-scale power hardware-in-the-loop experiment including embedded controllers and more than 100 powered appliance loads and DER connected to a simulated real-world distribution system with more than 10,000 controlled devices. Experimental results from multiple scenarios confirm that the optimal FFR dispatch approach scales well and can optimally coordinate more than 10,000 net-load resources across a distribution network while achieving hardware response times within 500 ms, which is not possible using state-of-the-art optimal coordination approaches.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Deep Reinforcement Learning Enabled Physical-Model-Free Two-Timescale Voltage Control Method for Active Distribution Systems

Active distribution networks are being challenged by frequent and rapid voltage violations due to renewable energy integration. Conventional model-based voltage control methods rely on accurate parameters of the distribution networks, which are difficult to achieve in practice. This paper proposes a novel physical-model-free two-timescale voltage control framework for active distribution systems. To achieve fast control of PV inverters, the whole network is first partitioned into several subnetworks using voltage-reactive power sensitivity. Then, the scheduling of PV inverters in the multiple sub-networks is formulated as Markov games and solved by a multi-agent soft actor-critic (MASAC) algorithm, where each subnetwork is modeled as an intelligent agent. All agents are trained in a centralized manner to learn a coordinated strategy while being executed based on only local information for fast response. For the slower time-scale control, OLTCs and switched capacitors are coordinated by a single agent-based SAC algorithm using the global information with considering control behaviors of the inverters. Particularly, the two-level agents are trained concurrently with information exchange according to the reward signal calculated from the data-driven surrogate model. Comparative tests with different benchmark methods on IEEE 33-and 123-bus systems and 342-node low voltage distribution system demonstrate that the proposed method can effectively mitigate the fast voltage violations and achieve systematical coordination of different voltage regulation assets without the knowledge of accurate system model.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Efficient Phasor-Based Dynamic Volt/VAr and Volt/Watt Analysis of Large Distribution Grid with High Penetration of Smart Inverters

As the penetration of power-electronics based smart inverters (SIs) is increasing in distribution grids, it adds computational challenges in solving dynamic models of large-scale distribution feeders. Voltage and reactive power (Volt/VAr), and voltage and active power (Volt/Watt) dynamics have been analyzed at slower time scales akin to the control of legacy grid devices. However, smart inverters, being power-electronics based devices, can provide dynamic active/reactive power support at a faster time scale, which necessitates Volt/VAr and Volt/Watt dynamics to be analyzed at a faster time scale. The existing dynamic models are overly detailed and computationally intractable for distribution feeders with a large number of inverters. In this context, this proposed work aims towards developing a computationally tractable, scalable, and accurate phasor-based model for dynamic Volt/VAr and Volt/Watt analyses of large distribution systems with high penetration of smart inverters. Case studies demonstrate that the proposed phasor-based model sufficiently captures the Volt/VAr and Volt/Watt dynamics, and is computationally faster by one order of magnitude compared to the average model and by two orders of magnitude compared to the detailed switching model. Case studies also demonstrate the efficacy and scalability of the proposed model in analyzing Volt/VAr and Volt/Watt dynamics of large-scale power networks with hundreds of SIs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Learning Distribution Grid Topologies: A Tutorial

Unveiling feeder topologies from data is of paramount importance to advance situational awareness and proper utilization of smart resources in power distribution grids. This tutorial summarizes, contrasts, and establishes useful links between recent works on topology identification and detection schemes that have been proposed for power distribution grids. The primary focus is to highlight methods that overcome the limited availability of measurement devices in distribution grids, while enhancing topology estimates using conservation laws of power-flow physics and structural properties of feeders. Grid data from phasor measurement units or smart meters can be collected either passively in the traditional way, or actively, upon actuating grid resources and measuring the feeder's voltage response. Analytical claims on feeder identifiability and detectability are reviewed under disparate meter placement scenarios. Such topology learning claims can be attained exactly or approximately so via algorithmic solutions with various levels of computational complexity, ranging from least-squares fits to convex optimization problems, and from polynomial-time searches over graphs to mixed-integer programs. Although the emphasis is on radial single-phase feeders, extensions to meshed and/or multiphase circuits are sometimes possible and discussed. Here this tutorial aspires to provide researchers and engineers with knowledge of the current state-of-the-art in tractable distribution grid learning and insights into future directions of work.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Integrating Transactive Energy into Reliability Evaluation for a Self-healing Distribution System with Microgrid

Non-utility owned distributed energy resources (DERs) are mostly untapped currently, but they can provide many grid services such as voltage regulation and service restoration, if properly controlled, and can improve the distribution systems reliability when coordinated with utility-owned assets such as self-healing control and microgrids. This paper integrates transactive energy control into the distribution system reliability evaluation to quantitatively assess the impact of non-utility owned DERs on reliability improvement. Here, a transactive reactive power control strategy is designed to incentivize the DERs to provide reactive power support for improving voltage profiles thus enabling additional customer load restoration during an outage. Also, an operational sequence to coordinate the non-utility owned DERs with the utility owned self-healing control and utility owned microgrids is designed and integrated into the service restoration process with the operational constraints guaranteed by checking the three-phase unbalanced power flow for post-fault network reconfiguration. The reliability indices are then calculated through a Monte Carlo simulation. The transactive reactive power control strategy is tested on a four-feeder distribution system operated by Duke Energy in the U.S. Results demonstrate that the non-utility owned DERs with the transactive control improve the reliability of both the system and critical loads by more than 30%.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Analysis of the Angular Distribution of Emission of Neutrons Generated with the Ponderomotive Mechanism of Ion Heating by High-Power Short Laser Pulse Acting on a (CD{sub 2}){sub n} Target

Experiments on the angular distribution of DD neutrons generated in nuclear reactions upon irradiation of a (CD{sub 2}){sub n} target have been performed in the “Neodymium” laser facility. Apart from the main pulse, prepulses were observed in the experiment. Measurements have shown that neutrons have an isotropic angular distribution. Experimental results have been analyzed using hydrodynamic calculations accounting for the ponderomotive force. The ion heating mechanism in a shock wave emerging under the action of the ponderomotive pressure of the main pulse in the supercritical region of the plasma has been considered. It is shown that neutrons are generated mainly in the supercritical plasma heated by the ion heat wave. The time of plasma cooling due to hydrodynamic spreading turns out to be much longer than the isotropization time of the ion velocity distribution function due to Coulomb collisions. In these conditions, the neutron angular distribution must be isotropic.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Transverse momentum and pseudorapidity distributions of final-state particles and spatial structure pictures of an interacting system in p-Pb collisions at $\sqrt{s_{NN}} = 5.02$ TeV

In this work, the transverse momentum and pseudorapidity distributions of final-state particles produced in proton-lead (p-Pb) collisions at center-of-mass energy per nucleon pair $\sqrt{s_{NN}} = 5.02$ TeV are studied in the framework of a multisource thermal model. Experimental results measured by the ALICE and CMS Collaborations are described by the Tsallis transverse momentum distribution and the two-cylinder pseudorapidity distribution. Based on the parameter values extracted from the transverse momentum and pseudorapidity distributions, some other quantities are extracted. Then, the structure pictures of interacting system at the stage of kinetic freeze-out in some spaces are obtained

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Impacts of Using Distributed Energy Resources to Reduce Peak Loads in Vermont

To help the United States develop a modern electricity grid that provides reliable power from multiple resources as well as resiliency under extreme conditions, the U.S. Department of Energy (DOE) is leading the Grid Modernization Initiative (GMI) to help shape the future of the nation's grid. Under the GMI, DOE funded the Vermont Regional Initiative project to provide the technical support and analysis to utilities that need to mitigate possible impacts of increasing renewable generation required by statewide goals. Advanced control of distributed energy resources (DER) can both support higher penetrations of renewable energy by balancing controllable loads to wind and photovoltaic (PV) solar generation and reduce peak demand by shedding noncritical loads. This work focuses on the latter. This document reports on an experiment that evaluated and quantified the potential benefits and impacts of reducing the peak load through demand response (DR) using centrally controllable electric water heaters (EWHs) and batteries on two Green Mountain Power (GMP) feeders. The experiment simulated various hypothetical scenarios that varied the number of controllable EWHs, the amount of distributed PV systems, and the number of distributed residential batteries. The control schemes were designed with several objectives. For the first objective, the primary simulations focused on reducing the load during the independent system operator (ISO) peak when capacity charges were the primary concern. The second objective was to mitigate DR rebound to avoid new peak loads and high ramp rates. The final objective was to minimize customers' discomfort, which is defined by the lack of hot water when it is needed. We performed the simulations using the National Renewable Energy Laboratory's (NREL's) Integrated Energy System Model (IESM) because it can simulate both electric power distribution feeder and appliance end use performance and it includes the ability to simulate multiple control strategies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Distributed Wind Resource Assessment Framework: Functional Requirements and Metrics for Performance and Reliability Modeling

The focus of the distributed wind resource assessment (DWRA) performance framework is to first clarify the key parameters that define the wind resource for any distributed wind turbine project and then describe the loss and uncertainty factors associated with long-term performance of wind turbine projects. Next it will identify and define the key parameters required to analyze the operational performance of a project. This framework could then be the foundation for understanding the predictability of the power and revenue from a project. Improving the predictability and reliability of wind power generation and operations will reduce costs and potentially establish a framework to attract new capital to the distributed wind industry sector. This report is the first part of a research effort to investigate the impact that improved resource assessment and energy estimation for distributed wind can have on consumer confidence, cost of capital, cost of ownership and operations, perception of financial risk, and levelized cost of energy.

17 WIND ENERGY↗

Distribution Capacity Expansion Planning: Current Practice, Opportunities, and Decision Support

The distribution utility industry and its engineers are experiencing monumental shifts in consumer needs and expectations. Characterizing future native loads as compared to net load demand for long-term capacity planning is especially difficult, as consumers are increasingly adopting prosumer technologies. This paper is the culmination of 5 months of utility interviews coordinated by the National Renewable Energy Lab (NREL) and Kevala, Inc. (Kevala) to better understand distribution capacity planning challenges. The interviews covered all aspects of capacity planning including load and DER forecasting, criteria for assessing system constraints, solution types, and organizational and decision-making structures. Our intent is to provide insight into distribution capacity planning decision support needs for utilities and the increasing number of stakeholders involved, from state and regulatory agencies to community and solution providers with interest in increasing their understanding in the distribution capacity planning process.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Distributed Wind Market Report: 2023 Edition

The annual Distributed Wind Market Report provides stakeholders with market statistics and analysis along with insights into market trends and characteristics for wind technologies used as distributed energy resources. This report presents the distributed wind market from 2003 through 2022. Installed capacity, deployment trends, customer types, incentives, policies, installed costs, performance, and the future outlook for the distributed wind market are the key topics included in the report.

17 WIND ENERGY↗

Scheduler Modeling of Distributed Energy Resources for Providing Ancillary Services

Distribution energy resources (DERs) have been integral components of modern power systems, and their capability to provide grid services has been widely studied. To promote the deployment of these resources in providing grid services in real-world utility operations, this paper proposes a day-ahead scheduler model for a distribution system connected DER plant. A certain amount of generation capacity of this DER plant is reserved for frequency services, and some ancillary services for the distribution system-including peak load reduction, voltage regulation, and power factor control-are integrated into the model. The model is tested on a real-world distribution system. From the simulation results, the energy and reserve schedule of the solar photovoltaic (PV) unit and battery energy storage system (BESS) can be determined, and voltage and power factor are well maintained. Additionally, in order to demonstrate the specific characteristics of the co-located and hybrid operation modes for the PV and BESS, these two modes are analyzed both theoretically and through real-time simulation. Simulation results show that most of PV's variability is transferred to the net power in the co-located mode, whereas it is transferred to the BESS in the hybrid mode. This proposed scheduler model and the comparison of co-located and hybrid modes can provide practical guidance for the applications of DER plant in the real-world utility.

14 SOLAR ENERGY↗

Strategies for Flood Resilience and Grid Investment Among Iowa's Electric Distribution Utilities

Flooding poses a growing threat to Iowa's electric distribution system, yet utilities face significant data and modeling challenges in planning effective resilience investments. This report provides a foundational assessment of how distribution utilities in Iowa, investor-owned, municipal, and cooperative, approach resilience planning, with a focus on flood risk. It combines hazard characterization, review of state and utility practices, and application of NLR's Energy Resilience Analysis for Distribution Systems (ERAD) and Capacity Expansion Decision Support for Distribution Networks (CADET) tools. Using FEMA floodplains, Iowa Flood Center depth grids, and utility infrastructure data, the analysis quantifies asset exposure, simulates outage risks, and evaluates resilience strategies such as pole hardening, undergrounding, and substation protection. Results indicate that while feeder-level upgrades provide incremental benefits, the most significant reductions in outage risk are achieved through targeted substation interventions. The report highlights key data gaps, such as limited elevation data and fragility functions, and underscores the need for probability-weighted investment frameworks to address both frequent and catastrophic flood events. These insights aim to support utilities, state agencies, and federal partners in prioritizing resilience investments that safeguard Iowa's electric grid against future flooding.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Network-Cognizant Time-Coupled Aggregate Flexibility of Distribution Systems Under Uncertainties

Increasing integration of distributed energy resources (DERs) within distribution feeders provides unprecedented flexibility at the distribution-transmission interconnection. To exploit this flexibility and to use the capacity potential of aggregate DERs, feasible substation power injection trajectories need to be efficiently characterized. This paper provides an ellipsoidal inner approximation of the set of feasible power injection trajectories at the substation such that for any point in the set, there exists a feasible disaggregation strategy of DERs for any load uncertainty realization. The problem is formulated as one of finding the robust maximum volume ellipsoid inside the flexibility region under uncertainty. Though the problem is NP-hard even in the deterministic case, this paper derives novel approximations of the resulting adaptive robust optimization problem based on optimal second-stage policies. The proposed approach yields less conservative flexibility characterization than existing flexibility region approximation formulations. The efficacy of the proposed method is demonstrated on a realistic distribution feeder.

aggregates↗

Multi-Area Distribution System State Estimation Using Decentralized Physics-Aware Neural Networks

The development of active distribution grids requires more accurate and lower computational cost state estimation. In this paper, the authors investigate a decentralized learning-based distribution system state estimation (DSSE) approach for large distribution grids. The proposed approach decomposes the feeder-level DSSE into subarea-level estimation problems that can be solved independently. The proposed method is decentralized pruned physics-aware neural network (D-P2N2). The physical grid topology is used to parsimoniously design the connections between different hidden layers of the D-P2N2. Monte Carlo simulations based on one-year of load consumption data collected from smart meters for a three-phase distribution system power flow are developed to generate the measurement and voltage state data. The IEEE 123-node system is selected as the test network to benchmark the proposed algorithm against the classic weighted least squares and state-of-the-art learning-based DSSE approaches. Numerical results show that the D-P2N2 outperforms the state-of-the-art methods in terms of estimation accuracy and computational efficiency.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Review of Distributed Secondary Control Architectures in Islanded-Inverter-Based Microgrids

The increasing energy demand, the shortage of energy resources, and the environmental challenges faced by conventional power-generation systems are some of the ongoing challenges faced by modern power systems. Therefore, many efforts have been made by the scientific community to develop comprehensive solutions to overcome these issues. For instance, current technological advances have allowed the integration of distributed generators into the power systems, promoting the use of microgrids to overcome these issues. However, the use of renewable distributed generators have introduced new challenges to the traditional control system schemes. To overcome these challenges, a hierarchical control approach has been proposed for distributed renewable sources. In other words, the control scheme have been divided into three hierarchical levels, primary, secondary, and tertiary, to overcome the new challenges present in modern power systems. Due to extensiveness of this topic, this overview is focused on secondary control systems, mainly for AC isolated microgrids. To improve the power quality of modern systems, several secondary control schemes have been proposed to overcome the well-known problem of frequency and voltage deviation. Some of these schemes have also introduced adequate active/reactive power sharing techniques to optimize the utilization of resources. Additionally, other secondary control schemes have also focused on reducing the communication load, to lower the network cost and adding robustness against communication problems. This article presents an insight of the different control techniques used to overcome power quality and communication problems. A comprehensive overview of distributed secondary control techniques for islanded microgrids is presented. In addition, the implementation of these techniques is explained in an orderly and sequential manner.

14 SOLAR ENERGY↗

POLARIZED SYNCHROTRON EMISSIVITIES AND ABSORPTIVITIES FOR RELATIVISTIC THERMAL, POWER-LAW, AND KAPPA DISTRIBUTION FUNCTIONS

Synchrotron emission and absorption determine the observational appearances of many astronomical systems. In this paper, we describe a numerical scheme for calculating synchrotron emissivities and absorptivities in all four Stokes parameters for arbitrary gyrotropic electron distribution functions, building on earlier work by Leung, Gammie, and Noble. We use this technique to evaluate the emissivities and the absorptivities for a thermal (Maxwell–Jüttner), isotropic power-law, and an isotropic kappa distribution function. The latter contains a power-law tail at high particle energies that smoothly merges with a thermal core at low energies, as is characteristic of observed particle spectra in collisionless plasmas. We provide fitting formulae and error bounds on the fitting formulae for use in codes that solve the radiative transfer equation. The numerical method and the fitting formulae are implemented in a compact C library called symphony. We find that the kappa distribution has a source function that is indistinguishable from a thermal spectrum at low frequency and transitions to the characteristic self-absorbed synchrotron spectrum, ∝ν{sup 5/2}, at high frequency; the linear polarization fraction for a thermal spectrum is near unity at high frequency; and all distributions produce O(10%) circular polarization at low frequency for lines of sight sufficiently close to the magnetic field vector.

79 ASTRONOMY AND ASTROPHYSICS↗

CACTI: Best Estimate Aerosol Size Distribution by airborne measurements

These data were collected during the Cloud, Aerosol, and Complex Terrain Interactions (CACTI; https://www.arm.gov/research/campaigns/amf2018cacti ) field campaign in the Sierras de Córdoba mountain range of north-central Argentina as part of ARM Aerial Facility (AAF) deployment. The ARM Aerial Facility Gulfstream-1 was operated from Las Higueras Airport (IATA: RCU, ICAO: SAOC), Río Cuarto, Córdoba, Argentina, for the Intensive Observation Period (IOP) from Nov. 1 through Dec. 15, 2018. The G-1 aircraft performed 22 research flights over the first ARM Mobile Facility (AMF1) location in the Sierras de Córdoba mountain range to measure atmospheric state and turbulence, cloud water content and droplet size distributions, aerosol precursor gases, aerosol chemical composition and size distributions. The current data set presents Best Estimate Aerosol Size Distribution: a merged aerosol size distribution composed of the data from 5 sensors; three aerosol spectrometers: Scanning Mobility Particle Sizer (SMPS), Ultra-High Sensitivity Aerosol Spectrometer (UHSAS), and Passive Cavity Aerosol Spectrometer (PCASP); and two cloud probes: Cloud Aerosol Spectrometer (CAS) and Fast Cloud Droplet Probe (FCDP). The SMPS data were interpolated to 1 second from “native” time resolution of about 64 second to match all other probes.

54 ENVIRONMENTAL SCIENCES↗