Search NASA⌕ Search

SEARCH · Search NASA

Results for “embedded methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,765 records · Page 98

Novel Transparent Phosphor Conversion Matrix with High Thermal Conductivity for Next Generation Phosphor-Converted LED-based Solid State Lighting

The low thermal conductivity of state-of-the-art polymer encapsulants (k ~ 0.15 Wm-1K-1) limits the efficiency and power density of current phosphor conversion light emitting diodes (pc-LEDs). The technical objective of this project was to demonstrate synthesis and processing schemes for the fabrication of polymer hybrid encapsulants with a thermal conductivity exceeding k = 0.4 Wm-1K-1 for LED applications. The ‘hybrid polymer’ approach encompasses the dispersion of high thermal conductivity particle fillers (zinc oxide, ZnO as well as the alpha-polymorph of alumina, Al2O3) within a polysiloxane matrix (poly(dimethylsiloxane), PDMS as well as poly(phenyl methyl siloxane), PPMS) to increase the thermal conductivity while maintaining optical transparency and photothermal stability at levels consistent with LED applications. To accomplish this goal, a novel synthesis method for the fabrication of nanosized ZnO particles was developed and a novel surface chemistry was established to modify the surface of zinc oxide particle fillers and thus to enable their dispersion in poly(dimethyl siloxane) (PDMS) matrix polymers. Molecular dynamics and Mie simulations were used to optimize ligand structure and to enable the concurrent mixing of particles in PDMS/PPMS embedding media while also minimizing the thermal boundary resistance as well as optical scattering of particle fillers. Using this approach the synthesis of PDMS/ZnO hybrid encapsulants exhibiting a thermal conductivity of 0.64 Wm-1K-1 and optical transparency > 0.7 mm-1 was demonstrated. A forming process based on micromolding was developed to demonstrate the forming of particle filled PDMS into film and lens shapes. Photothermal stability testing revealed stability of the materials for approximately 4000 min when exposed to blue light LED (450 nm, 30 W/cm2). One postgraduate and seven graduate students were supported by the project. The research performed within this project led to fifteen publications in peer-reviewed journals and one patent application. The grant stimulated a multi-investigator research collaborations among seven investigators at Carnegie Mellon University to address the challenge of encapsulants in pc-LED applications. The grant also catalyzed the future collaboration between researchers at Carnegie Mellon University and OSRAM Sylvania to address challenges associated with the use if polymers in LED applications.

36 MATERIALS SCIENCE↗

Cold Sintered Ceramics and Cements for Part Encapsulation

In this project, ceramic encapsulation materials were studied for high temperature (>~°500 C) applications where typical polymer encapsulants are unstable. A new low temperature (<~°200 C) method of processing ceramics, the cold sintering process was examined. Additionally, commercially available high temperature ceramic cements were investigated. In both cases, the mechanical strengths of available materials are less than desired (i.e., desired strengths similar to Si 3 N 4 ), limiting applicability. Composite designs to increase mechanical strength are suggested. Additionally, non-uniformities in stresses and densification while embedding alumina sheets in encapsulants via cold sintering using uni-axial pressing led to fracture of sheets, and an alternative iso-static based approach is recommended for future studies.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Field Results from New Tensor Borehole Optical Fiber Strainmeter Installations in Oklahoma and Utah

The time evolving strain field contains a wealth of information that can be used to interpret subsurface behavior. For example, injecting or removing fluids from reservoirs or aquifers causes deformation that can be used as a diagnostic signal in some cases, while it can interfere with geodetic interpretations in other cases. We've previously demonstrated the feasibility of measuring the strain tensor at a depth of 30m caused by injection into a reservoir at 530m. The observed strain signals were interpreted using four independent analytic and numerical methods that resulted in estimates of the poroelastic properties and geometry of the reservoir that was consistent with data from well logs. However, studies like these are only possible if these deformations can be reliably measured. Years of lab and field work has culminated in the development of a novel borehole strainmeter capable of resolving multiple components of strain using embedded optical fibers configured as Michelson interferometers. It features four horizontal gauges separated by 45° to resolve the horizontal strain tensor as well as a vertical strain gauge and a sixth null component for state-of-health monitoring. The downhole sensing package also includes an open pipe through its center for grout circulation during single-trip deployments and a fully welded stainless steel exterior for robustness and longevity. These instruments have a resolution of 2x10-13 strain that can easily measure the solid earth tides. Preliminary data are available from four strainmeters in shale at our Oklahoma site and four in compacted sand and gravel in Utah. These are deployed from 40-60m, except one of the strainmeters in Oklahoma is deployed at 500m. The data include strains from the initial grout curing, comparisons to predicted earth tide models and in-situ calibration results, barometric pressure admittances and spectral analyses as well as signals from underground injections and surface waves from teleseismic events. Preliminary analyses indicate behavior consistent with other strainmeter deployments, and comparison to data from a Gladwin strainmeter at the Oklahoma site validate the performance of the new design. Analyses from a suite of six well tests at the Oklahoma site show for the first time how the strain tensor field varies with location during well testing.

DeWolf, Scott↗

From Theory to Practice: Lessons Learned from an Advanced M&V Commercial Pilot

Advanced measurement & verification (M&V), or M&V 2.0, is an energy data analysis method using advanced metering infrastructure (AMI) data in combination with analytics to quantify energy efficiency project savings. Advanced M&V is viewed as an enabler for underutilized behavioral, retrocommissioning, and holistic multi-measure efficiency efforts, as quantifying savings for these programs with existing methods has typically been very challenging. Despite its promise, there are still several unanswered questions about the use of advanced M&V such as: How accurately can these tools quantify energy savings? How can advanced M&V satisfy regulatory requirements for rigorous savings estimates? Where and how does advanced M&V intersect with traditional impact evaluation and the principles of ‘embedded’ evaluation, measurement & verification (EM&V)? Pilots are being pursued in various regions and program contexts to address these research questions. However, results from these pilots are rarely made public, meaning that lessons may not be widely shared and the scope of analyses varies widely. The paper presents encouraging results from a recent advanced M&V pilot and discusses key process-related aspects such as managing AMI data and refining analysis methodologies. An approach to reviewing and classifying projects based on savings characteristics and magnitude is demonstrated, as a potential risk management tool. The authors also demonstrate how advanced M&V can identify underperforming projects and non-routine events in a timely manner. The paper also outlines lessons learned from this and other recent pilot activity and barriers to be overcome in moving toward the goal of widespread adoption of holistic meter-based programs.

Crowe, Eliot↗

Software Quality Metrics for Geant4: An Initial Assessment - Paper 122

In the context of critical applications, such as shielding and radiation protection, ensuring the quality of simulation software they depend on is of utmost importance. The assessment of simulation software quality is crucial both to determine its adoption in experimental applications and to guarantee reproducibility of outcome over time. Geant4 is a simulation system used in a wide range of experimental applications, some of which, such as radiation protection and biomedical studies, may involve critical use cases and would especially profit from an objective assessment of the software quality. In this study, we present the first results from an ongoing analysis of Geant4 code based on established software metrics from the perspective of software engineering. The analysis evaluates the current status of the code to quantify its characteristics with respect to documented quality standards; further appraisals concern evolutions over a series of release distributions. The quantitative assessment of the software is initially focused on a subset of Geant4 packages, which play a key role in scientific applications and are representative of different software development processes. We describe the chosen software metrics that map the entities of a software system to numeric values through mathematical definitions, quantifying software attributes ranging from functionality to maintainability. To measure such metrics, we exploited a set of software metrics tools, i.e. programs that implement a set of software metrics definitions. They allow software engineers to assess a software system by extracting the required attributes from the software and providing the corresponding metric values. To correlate software metrics values in a well-defined way, we used software quality standard models, such as the ISO/IEC 9126 standard, which aggregate numerical values to aid quality analysis and assessment. With this work we aim to create a baseline for evaluating correlations between software quality embedded in the Geant4 development process and simulation observables produced by Geant4-based applications. Furthermore, we intend to highlight what metrics are most effective at evaluating radiation transport software quality. We are confident that the result will provide constructive guidance both to improve key software tools, such as Geant4, and to estimate their contribution in risk analysis concerning sensitive applications. The remainder of this paper is structured as follows. We first discuss the approach adopted to fulfil our assessment. Then, we present the setup of our experiments and the way we collected data. We provide an initial interpretation of a subset of data resulting from measurements made on the selected Geant4 packages. As the analysis is still ongoing at the time of submitting this abstract, some results will be documented in the final paper and in the conference presentation. With this work we aim to create a proper Geant4 data set for evaluating its software characteristics and identifying both strengths and weaknesses. In this initial study, we considered the geometry and processes packages, which play a major role in most simulation applications. The data analysis is in progress at the time of writing; its complexity is related to the differences among software metrics tools, to the large amount of data to be evaluated and to the pioneering character of this project. We are confident that the results will provide valuable indications for the Geant4 user community and constructive guidance to improve key Geant4 packages. Other Monte Carlo codes could profit from the methodology developed in this pilot project for similar assessments of their software quality. At the end of this study, we intend to create a baseline for evaluating correlations between software quality embedded in the Geant4 development process and simulation observables produced by Geant4-based applications. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Verification and source-position error analysis of film reconstruction techniques used in the brachytherapy planning systems

A method was presented that employs standard linac QA tools to verify the accuracy of film reconstruction algorithms used in the brachytherapy planning system. Verification of reconstruction techniques is important as suggested in the ESTRO booklet 8: ''The institution should verify the full process of any reconstruction technique employed clinically.'' Error modeling was also performed to analyze seed-position errors. The ''isocentric beam checker'' device was used in this work. It has a two-dimensional array of steel balls embedded on its surface. The checker was placed on the simulator couch with its center ball coincident with the simulator isocenter, and one axis of its cross marks parallel to the axis of gantry rotation. The gantry of the simulator was rotated to make the checker behave like a three-dimensional array of balls. Three algorithms used in the ABACUS treatment planning system: orthogonal film, 2-films-with-variable-angle, and 3-films-with-variable-angle were tested. After exposing and digitizing the films, the position of each steel ball on the checker was reconstructed and compared to its true position, which can be accurately calculated. The results showed that the error is dependent on the object-isocenter distance, but not the magnification of the object. The averaged errors were less than 1 mm within the tolerance level defined by Roueet al. [''The EQUAL-ESTRO audit on geometric reconstruction techniques in brachytherapy,'' Radiother. Oncol. 78, 78-83 (2006)]. However, according to the error modeling, the theoretical error would be greater than 2 mm if the objects were located more than 20 cm away from the isocenter with a 0.5 deg. reading error of the gantry and collimator angles. Thus, in addition to carefully performing the QA of the gantry and collimator angle indicators, it is suggested that the patient, together with the applicators or seeds inside, should be placed close to the isocenter as much as possible. This method could be used to test the reconstruction techniques of any planning system, and the most suitable one can be chosen for clinical use.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Using synchrotron X-ray phase-contrast micro-computed tomography to study tissue damage by laser irradiation: STUDY TISSUE DAMAGE BY LASER IRRADIATION

Background and Objective: The aim of this study was to determine if X-ray micro-computed tomography could be used to locate and characterize tissue damage caused by laser irradiation and to describe its advantages over classical histology for this application. Study Design/Materials and Methods: A surgical CO2 laser, operated in single pulse mode (100 milliseconds) at different power settings, was used to ablate different types of cadaveric animal tissues. Tissue samples were then harvested and imaged with synchrotron X-ray phasecontrast and micro-computed tomography to generate stacks of virtual sections of the tissues. Subsequently, Fiji (ImageJ) software was used to locate tissue damage, then to quantify volumes of laser ablation cones and thermal coagulation damage from 3D renderings of tissue image stacks. Visual comparisons of tissue structures in X-ray images with those visible by classic light microscopy histology were made. Results: We demonstrated that micro-computed tomography could be used to rapidly identify areas of surgical laser ablation, vacuolization, carbonization, and thermally coagulated tissue. Quantification and comparison of the ablation crater, which represents the volume of ablated tissue, and the thermal coagulation zone volumeswere performed faster than we could by classical histology. We demonstrated that these procedures can be performed on fresh hydrated and non-sectioned plastic embedded tissue. Conclusion: We demonstrated that the application of non-destructive micro-computed tomography to the visualization and analysis of laser induced tissue damage without tissue sectioning is possible. This will improve evaluation of new surgical lasers and their corresponding effect on tissues.

Ablation↗

Segmentation and quantification of materials with energy discriminating computed tomography: A phantom study

Purpose: To experimentally investigate whether a computed tomography (CT) system based on CdZnTe (CZT) detectors in conjunction with a least-squares parameter estimation technique can be used to decompose four different materials. Methods: The material decomposition process was divided into a segmentation task and a quantification task. A least-squares minimization algorithm was used to decompose materials with five measurements of the energy dependent linear attenuation coefficients. A small field-of-view energy discriminating CT system was built. The CT system consisted of an x-ray tube, a rotational stage, and an array of CZT detectors. The CZT array was composed of 64 pixels, each of which is 0.8x0.8x3 mm. Images were acquired at 80 kVp in fluoroscopic mode at 50 ms per frame. The detector resolved the x-ray spectrum into energy bins of 22-32, 33-39, 40-46, 47-56, and 57-80 keV. Four phantoms were constructed from polymethylmethacrylate (PMMA), polyethylene, polyoxymethylene, hydroxyapatite, and iodine. Three phantoms were composed of three materials with embedded hydroxyapatite (50, 150, 250, and 350 mg/ml) and iodine (4, 8, 12, and 16 mg/ml) contrast elements. One phantom was composed of four materials with embedded hydroxyapatite (150 and 350 mg/ml) and iodine (8 and 16 mg/ml). Calibrations consisted of PMMA phantoms with either hydroxyapatite (100, 200, 300, 400, and 500 mg/ml) or iodine (5, 15, 25, 35, and 45 mg/ml) embedded. Filtered backprojection and a ramp filter were used to reconstruct images from each energy bin. Material segmentation and quantification were performed and compared between different phantoms. Results: All phantoms were decomposed accurately, but some voxels in the base material regions were incorrectly identified. Average quantification errors of hydroxyapatite/iodine were 9.26/7.13%, 7.73/5.58%, and 12.93/8.23% for the three-material PMMA, polyethylene, and polyoxymethylene phantoms, respectively. The average errors for the four-material phantom were 15.62% and 2.76% for hydroxyapatite and iodine, respectively. Conclusions: The calibrated least-squares minimization technique of decomposition performed well in breast imaging tasks with an energy resolving detector. This method can provide material basis images containing concentrations of the relevant materials that can potentially be valuable in the diagnostic process.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Measurement of 227 Ac impurity in 225 Ac using decay energy spectroscopy

225 Ac is a valuable medical radionuclide for targeted $\alpha$ therapy, but 227 Ac is an undesirable byproduct of an accelerator-based synthesis method under investigation. Sufficient detector sensitivity is critical for quantifying the trace impurity of 227 Ac, with the 227 Ac/ 225 Ac activity ratio predicted to be approximately 0.15% by end-of-bombardment (EOB). Superconducting transition edge sensor (TES) microcalorimeters offer high resolution energy spectroscopy using the normal-to-superconducting phase transition to measure small changes in temperature. By embedding 225 Ac production samples in a gold foil thermally coupled to a TES microcalorimeter we can measure the decay energies of the radionuclides embedded with high resolution and 100% detection efficiency. This technique, known as decay energy spectroscopy (DES), collapses several peaks from $\alpha$ decays into single Q-value peaks. In practice there are more complex factors in the interpretation of data using DES, which we will discuss in this paper. Using this technique we measured the EOB 227 Ac impurity to be (0.142 ± 0.005)% for a single production sample. This demonstration has shown that DES is a useful tool for quantitative measurements of complicated spectra.

07 ISOTOPE AND RADIATION SOURCES↗

Correlation between processing conditions, microstructure and charge transport in half-Heusler alloys

Five bulk samples of n-type Zr₀.₂₅Hf₀.₇₅NiSn₀.₉₇₅Sb₀.₀₂₅ half-Heusler (HH) alloy were fabricated by reacting elemental powders via (1) high temperature solid state (SS) reaction and (2) mechanical alloying (MA), followed by densification using spark plasma sintering (SPS) and/or hot pressing (HP). A portion of the sample obtained by SS reaction was mechanically alloyed before consolidation by hot pressing (SS–MA–HP). X-ray powder diffraction and transmission electron microscopy studies revealed that all SS specimen (SS–SPS, SS–HP, SS–MA–HP) are single phase HH alloys, whereas the MA sample (MA–SPS) contains metallic nanoprecipitates. Electronic and thermal transport measurements showed that the embedded nanoprecipitates induce a drastic increase in the carrier concentration (n), a large decrease in the Seebeck coefficient (S) and a marginal decrease in the lattice thermal conductivity (κ l ) of the MA–SPS sample leading to lower ZT values when compared to the SS–HP samples. Constant values of S are observed for the SS series regardless of the processing method. However, a strong dependence of the carrier mobility (μ), electrical conductivity (σ) and κ l on the processing and consolidation method is observed. For instance, mechanical alloying introduces additional structural defects which enhance electron and phonon scattering leading to moderately low values of μ and large reduction in κ l . This results in a net 20% enhancement in the figure of merit (ZT=0.6 at 775 K). HH specimen of the same nominal composition with higher ZT is anticipated from a combination of SS reaction, MA and SPS (SS–MA–SPS). - Graphical abstract: In half-Heusler alloys, thermopower values are insensitive to processing method, whereas carrier mobility (μ), electrical conductivity (σ), and κ l strongly dependent on the microstructure which in turn is altered by the synthesis, processing and consolidation method. Highlights: • Phase composition of HH alloy strongly depends on the synthesis technique. • Mechanical alloying of elements yields bulk HH alloy with metallic impurity phases. • Thermopower, carrier density, and effective mass of HHs are insensitive to processing conditions. • Mechanical alloying decreases the carrier mobility and lattice thermal conductivity of bulk HH.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

MULTIBAND NONTHERMAL RADIATIVE PROPERTIES OF HESS J1813-178

The source HESS J1813-178 was detected in a survey of the inner Galaxy in TeV {gamma}-rays, and a composite supernova remnant (SNR) G12.8-0.0 was identified in the radio band to be associated with it. The pulsar wind nebula (PWN) embedded in the SNR is powered by an energetic pulsar PSR J1813-1749, which was recently discovered. Whether the TeV {gamma}-rays originate from the SNR shell or the PWN is currently uncertain. We theoretically investigate the multiwavelength nonthermal radiation from the composite SNR G12.8-0.0. The emission from the particles accelerated in the SNR shell is calculated by applying a semianalytical method to the nonlinear diffusive shock acceleration mechanism. In the model, the magnetic field is self-generated via resonant streaming instability, and the dynamical reaction of the field on the shock is taken into account. Based on a model which couples the dynamical and radiative evolution of a PWN in a non-radiative SNR, the dynamics and the multiband emission of the PWN are investigated. The particles are injected with the spectrum of a relativistic Maxwellian plus a power-law high-energy tail with an index of -2.5. Our results indicate that the radio emission from the shell can be reproduced well as synchrotron radiation of the electrons accelerated by the SNR shock; with an interstellar medium number density of 1.4 cm{sup -3} for the remnant, the {gamma}-ray emission from the SNR shell is insignificant and the observed X-rays and very high energy (VHE) {gamma}-rays from the source are consistent with the emission produced by electrons/positrons injected in the PWN via synchrotron radiation and inverse Compton scattering, respectively; the resulting {gamma}-ray flux for the shell is comparable to the detected one, only with a relatively larger density of about 2.8 cm{sup -3}. The VHE {gamma}-rays of HESS J1813-178 can be naturally explained to mainly originate from the nebula, although the contribution of the SNR shell becomes significant with a denser ambient medium.

79 ASTRONOMY AND ASTROPHYSICS↗

Tight-binding calculation studies of vacancy and adatom defects in graphene

Computational studies of complex defects in graphene usually need to deal with a larger number of atoms than the current first-principles methods can handle. We show a recently developed three-center tight-binding potential for carbon is very efficient for large scale atomistic simulations and can accurately describe the structures and energies of various defects in graphene. Using the three-center tight-binding potential, we have systematically studied the stable structures and formation energies of vacancy and embedded-atom defects of various sizes up to 4 vacancies and 4 embedded atoms in graphene. In conclusion, our calculations reveal low-energy defect structures and provide a more comprehensive understanding of the structures and stability of defects in graphene.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Ensembles of novelty detection classifiers for structural health monitoring using guided waves

Guided wave structural health monitoring uses sparse sensor networks embedded in sophisticated structures for defect detection and characterization. The biggest challenge of those sensor networks is developing robust techniques for reliable damage detection under changing environmental and operating conditions. To address this challenge, we develop a novelty classifier for damage detection based on one class support vector machines. We identify appropriate features for damage detection and introduce a feature aggregation method which quadratically increases the number of available training observations.We adopt a two-level voting scheme by using an ensemble of classifiers and predictions. Each classifier is trained on a different segment of the guided wave signal, and each classifier makes an ensemble of predictions based on a single observation. Using this approach, the classifier can be trained using a small number of baseline signals. We study the performance using monte-carlo simulations of an analytical model and data from impact damage experiments on a glass fiber composite plate.We also demonstrate the classifier performance using two types of baseline signals: fixed and rolling baseline training set. The former requires prior knowledge of baseline signals from all environmental and operating conditions, while the latter does not and leverages the fact that environmental and operating conditions vary slowly over time and can be modeled as a Gaussian process.

Dib, Gerges (ORCID:0000000255004047)↗

SpeckleNN: a unified embedding for real-time speckle pattern classification in X-ray single-particle imaging with limited labeled examples

With X-ray free-electron lasers (XFELs), it is possible to determine the three-dimensional structure of noncrystalline nanoscale particles using X-ray single-particle imaging (SPI) techniques at room temperature. Classifying SPI scattering patterns, or `speckles', to extract single-hits that are needed for real-time vetoing and three-dimensional reconstruction poses a challenge for high-data-rate facilities like the European XFEL and LCLS-II-HE. Here, we introduce SpeckleNN, a unified embedding model for real-time speckle pattern classification with limited labeled examples that can scale linearly with dataset size. Trained with twin neural networks, SpeckleNN maps speckle patterns to a unified embedding vector space, where similarity is measured by Euclidean distance. We highlight its few-shot classification capability on new never-seen samples and its robust performance despite having only tens of labels per classification category even in the presence of substantial missing detector areas. Without the need for excessive manual labeling or even a full detector image, our classification method offers a great solution for real-time high-throughput SPI experiments.

47 OTHER INSTRUMENTATION↗

Compositional and Structural Characterization by TEM of Lattice-Mismatched III-V Epilayers

We discuss compositional and structural transmission electron microscopy (TEM) characterization of lattice-mismatched (LMM) III-V epilayers grown on GaAs by metalorganic chemical vapor deposition (MOCVD), with possible applications in high-efficiency multijunction solar cells. In addition to the use of TEM imaging to survey layer thicknesses and defect morphology, our analysis emphasizes the particular methods of energy-dispersive X-ray spectrometry (EDX) and convergent-beam electron diffraction (CBED). Outlined here is a standards-based method for extracting compositions by EDX, which uses principal-component analysis (PCA) [1], combined with the zeta-factor approach of Watanabe and Williams [2]. A procedure is described that uses the coordinates of high-order Laue zone (HOLZ) lines, which are found in the bright-field disks of CBED patterns, to extract composition and strain parameters from embedded epilayers. The majority of the crystal growth for this work was performed at NREL, which has accommodated the development at SDSM&T of the characterization techniques described. However, epilayer deposition capability at SDSM&T has recently been achieved, using a home-built system, which is presently being used to examine new lattice-mismatched structures relevant to photovoltaic technology.

14 SOLAR ENERGY↗

SU-E-T-303: Dosimetric Comparison of a LINAC Fallback Plan Generated From Tomotherapy System

Purpose: Quantitatively evaluate the Multi Criteria Optimization (MCO) based MLC step and shoot (sMLC) fallback plan derived from Tomotherapy of multiple lesions lung SBRT Methods: Inter-comparison of various IMRT planning systems tends to be difficult due to the vendor-specific functionalities. The methodology of defining dose constraints and beam geometries is challenging. Raysearch™ planning system offers an alternative replanning to deliver same intensity map from Tomotherapy without modifying original fluence. This intuitive comparison comes from the final fluence map converted without any embedded system dependent dose optimization. This planner independent approach could be utilized to study the merits of individual machines. The term “fallback” was utilized to (A) transfer plans in among treatment delivery systems; (B) maintain acceptable plan qualities; and (C) minimize the biological dose impact due to machine breakdown. The Tomotherapy specific DICOM RT dose and plan are retrieved into Raystation’s pre-defined sMLC protocol. Based on specific machine characteristics, same fluence maps were converted to generate equivalent deliverable segments. Therefore, the treatment plans were evaluated among two planning tools, Tomotherapy and MCO based sMLC delivery plans. Results: By converting the fluence map with the pre-defined machine characteristics, the 9-fields fallback plan has similar ITV coverage compared to the original Tomotherapy plan. ITV average doses, the D95 consisted of 0.9% variation. The total lung doses of fallback plan drifted from 17.4% to 30.5% which represents the limitations of the static beam delivery. D2 of fallback spinal cord increased from 22.4% to 36.4% but still within tolerances. Ipsilateral lung changed from 11.0% to 22.6%. Low dose region between ITVs presented increased dose to the normal lung tissues. Conclusion: Acceptable fallback plan for Tomotherapy SBRT has similar ITVs coverage, but lack of the normal tissues avoidance due to the limitation of geometrical factors to reduce doses in between ITVs.

60 APPLIED LIFE SCIENCES↗

Postoperative 3D spine reconstruction by navigating partitioning manifolds

Purpose: The postoperative evaluation of scoliosis patients undergoing corrective treatment is an important task to assess the strategy of the spinal surgery. Using accurate 3D geometric models of the patient’s spine is essential to measure longitudinal changes in the patient’s anatomy. On the other hand, reconstructing the spine in 3D from postoperative radiographs is a challenging problem due to the presence of instrumentation (metallic rods and screws) occluding vertebrae on the spine. Methods: This paper describes the reconstruction problem by searching for the optimal model within a manifold space of articulated spines learned from a training dataset of pathological cases who underwent surgery. The manifold structure is implemented based on a multilevel manifold ensemble to structure the data, incorporating connections between nodes within a single manifold, in addition to connections between different multilevel manifolds, representing subregions with similar characteristics. Results: The reconstruction pipeline was evaluated on x-ray datasets from both preoperative patients and patients with spinal surgery. By comparing the method to ground-truth models, a 3D reconstruction accuracy of 2.24 ± 0.90 mm was obtained from 30 postoperative scoliotic patients, while handling patients with highly deformed spines. Conclusions: This paper illustrates how this manifold model can accurately identify similar spine models by navigating in the low-dimensional space, as well as computing nonlinear charts within local neighborhoods of the embedded space during the testing phase. This technique allows postoperative follow-ups of spinal surgery using personalized 3D spine models and assess surgical strategies for spinal deformities.

61 RADIATION PROTECTION AND DOSIMETRY↗

Verification of New Floating Capabilities in FAST v8: Preprint

In the latest release of NREL's wind turbine aero-hydro-servo-elastic simulation software, FAST v8, several new capabilities and major changes were introduced. FAST has been significantly altered to improve the simulator's modularity and to include new functionalities in the form of modules in the FAST v8 framework. This paper is focused on the improvements made for the modeling of floating offshore wind systems. The most significant change was to the hydrodynamic load calculation algorithms, which are embedded in the HydroDyn module. HydroDyn is now capable of applying strip-theory (via an extension of Morison's equation) at the member level for user-defined geometries. Users may now use a strip-theory-only approach for applying the hydrodynamic loads, as well as the previous potential-flow (radiation/diffraction) approach and a hybrid combination of both methods (radiation/diffraction and the drag component of Morison's equation). Second-order hydrodynamic implementations in both the wave kinematics used by the strip-theory solution and the wave-excitation loads in the potential-flow solution were also added to HydroDyn. The new floating capabilities were verified through a direct code-to-code comparison. We conducted a series of simulations of the International Energy Agency Wind Task 30 Offshore Code Comparison Collaboration Continuation (OC4) floating semisubmersible model and compared the wind turbine response predicted by FAST v8, the corresponding FAST v7 results, and results from other participants in the OC4 project. We found good agreement between FAST v7 and FAST v8 when using the linear radiation/diffraction modeling approach. The strip-theory-based approach inherently differs from the radiation/diffraction approach used in FAST v7 and we identified and characterized the differences. Enabling the second-order effects significantly improved the agreement between FAST v8 and the other OC4 participants.

17 WIND ENERGY↗