Search NASA⌕ Search

SEARCH · Search NASA

Results for “error rate”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,765 records · Page 98

Randomization in Characterizing the Subsurface

Current methods for characterizing Earth’s subsurface, such as standard inverse techniques, are not sufficiently accurate to meet the needs of modern applications in the fields of energy exploration, environmental management, and global security. While increasing the quantity of field measurements and robustness of the applied data-/model-analysis methods can improve accuracy, such approaches can be computationally impractical for large data sets and complex site conditions. Thus, there is a need to develop economically-feasible and robust computational methods while maintaining accuracy. For example, in-field drilling for geothermal operations may yield high failure rates, resulting in unacceptably high costs; errors and/or large uncertainties in the estimated subsurface characteristics are the main impediment to the successful siting of an in-field well. This problem is not uniquely geothermal. Accurate characterization of uncertain subsurface properties is also essential for monitoring storage of carbon dioxide, estimating pathways of subsurface contaminant transport, and supervising ground-based nuclear-explosion tests.

58 GEOSCIENCES↗

Cyclic Prefix Direct Sequence Spread Spectrum Capacity Analysis

Cyclic Prefix Direct Sequence Spread Spectrum (CP-DSSS) is a novel waveform that has the potential to solve 5G objectives such as ultra reliable low latency communication (URLLC) and massive machine Type Communication (mMTC). This paper analyzes the capacity of the CP-DSSS waveform in comparison with Orthogonal Frequency Domain Multiplexing OFDM). CP-DSSS can be optimized to achieve the same capacity as OFDM when optimized by the water-filling algorithm. A significant advantage for CP-DSSS is that this capacity can be achieved with all symbols being transmitted with the same effective rate. As a result, stronger forward error correction codes can be used in a CP-DSSS implementation compared to an OFDM implementation with resource block constraints. In addition, the applicability of CP-DSSS as a waveform for a secondary network operating in the same frequency band as the primary network is discussed.

5G and Beyond Communications↗

An image-guidance system for dynamic dose calculation in prostate brachytherapy using ultrasound and fluoroscopy

Purpose: Brachytherapy is a standard option of care for prostate cancer patients but may be improved by dynamic dose calculation based on localized seed positions. The American Brachytherapy Society states that the major current limitation of intraoperative treatment planning is the inability to localize the seeds in relation to the prostate. An image-guidance system was therefore developed to localize seeds for dynamic dose calculation. Methods: The proposed system is based on transrectal ultrasound (TRUS) and mobile C-arm fluoroscopy, while using a simple fiducial with seed-like markers to compute pose from the nonencoded C-arm. Three or more fluoroscopic images and an ultrasound volume are acquired and processed by a pipeline of algorithms: (1) seed segmentation, (2) fiducial detection with pose estimation, (3) seed matching with reconstruction, and (4) fluoroscopy-to-TRUS registration. Results: The system was evaluated on ten phantom cases, resulting in an overall mean error of 1.3 mm. The system was also tested on 37 patients and each algorithm was evaluated. Seed segmentation resulted in a 1% false negative rate and 2% false positive rate. Fiducial detection with pose estimation resulted in a 98% detection rate. Seed matching with reconstruction had a mean error of 0.4 mm. Fluoroscopy-to-TRUS registration had a mean error of 1.3 mm. Moreover, a comparison of dose calculations between the authors’ intraoperative method and an independent postoperative method shows a small difference of 7% and 2% forD{sub 90} and V{sub 100}, respectively. Finally, the system demonstrated the ability to detect cold spots and required a total processing time of approximately 1 min. Conclusions: The proposed image-guidance system is the first practical approach to dynamic dose calculation, outperforming earlier solutions in terms of robustness, ease of use, and functional completeness.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Two-dimensional retrieval methods for ultrafast imaging of molecular structure using laser-induced electron diffraction

Molecular structural retrieval based on electron diffraction has been proposed to determine the atomic positions of molecules with sub-angstrom spatial and femtosecond temporal resolutions. Given its success on small molecular systems, in this work, we point out that the accuracy of structure retrieval is constrained by the availability of a wide range of experimental data in the momentum space in all molecular systems. To mitigate the limitations, for laser-induced electron diffraction, here we retrieve molecular structures using two-dimensional (energy and angle) electron momentum spectra in the laboratory frame for a number of small molecular systems, which have previously been studied with 1D methods. Compared to the conventional single-energy or single-angle analysis, our 2D methods effectively expand the momentum range of the measured data. Besides utilization of the 2D data, two complementary methods are developed for consistency check on the retrieved results. Further, the 2D nature of our methods also offers a way of estimating the error from retrieval, which has never been explored before. Comparing with results from prior experiments, our findings show evidence that our 2D methods outperform the conventional 1D methods. Paving the way to the retrieval of large molecular systems, in which their tunneling ionization rates are challenging to obtain, we estimate the error of using the isotropic model in place of including the orientation-dependent ionization rate.

74 ATOMIC AND MOLECULAR PHYSICS↗

SU-E-T-375: Evaluation of a MapCHECK2(tm) Planar 2-D Diode Array for High-Dose-Rate Brachytherapy Treatment Delivery Verifications

Purpose: Despite improvements of HDR brachytherapy delivery systems, verification of source position is still typically based on the length of the wire reeled out relative to the parked position. Yet, the majority of errors leading to medical events in HDR treatments continue to be classified as missed targets or wrong treatment sites. We investigate the feasibility of using dose maps acquired with a two-dimensional diode array to independently verify the source locations, dwell times, and dose during an HDR treatment. Methods: Custom correction factors were integrated into frame-by-frame raw counts recorded for a Varian VariSource™ HDR afterloader Ir-192 source located at various distances in air and in solid water from a MapCHECK2™ diode array. The resultant corrected counts were analyzed to determine the dwell position locations and doses delivered. The local maxima of polynomial equations fitted to the extracted dwell dose profiles provided the X and Y coordinates while the distance to the source was determined from evaluation of the full width at half maximum (FWHM). To verify the approach, the experiment was repeated as the source was moved through dwell positions at various distances along an inclined plane, mimicking a vaginal cylinder treatment. Results: Dose map analysis was utilized to provide the coordinates of the source and dose delivered over each dwell position. The accuracy in determining source dwell positions was found to be +/−1.0 mm of the preset values, and doses within +/−3% of those calculated by the BrachyVision™ treatment planning system for all measured distances. Conclusion: Frame-by-frame data furnished by a 2 -D diode array can be used to verify the dwell positions and doses delivered by the HDR source over the course of treatment. Our studies have verified that measurements provided by the MapCHECK2™ can be used as a routine QA tool for HDR treatment delivery verification.

60 APPLIED LIFE SCIENCES↗

Parameterization of bulk condensation in numerical cloud models

The accuracy of the moist saturation adjustment scheme has been evaluated using a three-dimensional explicit microphysical cloud model. It was found that the error in saturation adjustment depends strongly on the Cloud Condensation Nucleii (CCN) concentration in the ambient atmosphere. The scheme provides rather accurate results in the case where a sufficiently large number of CCN (on the order of several hundred per cubic centimeter) is available. However, under conditions typical of marine stratocumulus cloud layers with low CCN concentration, the error in the amounts of condensed water vapor and released latent heat may be as large as 40%-50%. A revision of the saturation adjustment scheme is devised that employs the CCN concentration, dynamical supersaturation, and cloud water content as additional variables in the calculation of the condensation rate. The revised condensation model reduced the error in maximum updraft and cloud water content in the climatically significant case of marine stratocumulus cloud layers by an order of magnitude.

Kogan, Yefim L.↗

Modelling of TGS growth in space

Attention is called to the necessity of programming the temperature downward in order to maintain a constant growth rate in the absence of convection. Trial and error numerical computations are performed to find the first approximation for the required isothermal dissolution period, linear ramp, and polynomial temperature variation period. The linear ramp rate is limited by the specified maximum temperature gradient. The isothermal dissolution turns out to be unnecessary. The linear ramp must be stopped before the polynomial period is begun in order to avoid overshooting the specified maximum growth rate. After a few hours, the temperature profile approaches steady-state behavior.

Liu, L. C.↗

Measurement of hybrid rocket solid fuel regression rate for a slab burner using deep learning

This study presents an imaging-based deep learning tool to measure the fuel regression rate in a 2D slab burner experiment for hybrid rocket fuels. The slab burner experiment is designed to verify mechanistic models of reacting boundary layer combustion in hybrid rockets by the measurement of fuel regression rates. A DSLR camera with a high intensity flash is used to capture images throughout the burn and the images are then used to find the fuel boundary to calculate the regression rate. A U-net convolutional neural network architecture is explored to segment the fuel from the experimental images. Here, a Monte-Carlo Dropout process is used to quantify the regression rate uncertainty produced from the network. The U-net computed regression rates are compared with values from other techniques from literature and show error less than 10%. An oxidizer flux dependency study is performed and shows the U-net predictions of regression rates are accurate and independent of the oxidizer flux, when the images in the training set are not over-saturated. Training with monochrome images is explored and is not successful at predicting the fuel regression rate from images with high noise. The network is superior at filtering out noise introduced by soot, pitting, and wax deposition on the chamber glass as well as the flame when compared to traditional image processing techniques, such as threshold binary conversion and spatial filtering. U-net consistently provides low error image segmentations to allow accurate computation of the regression rate of the fuel.

42 ENGINEERING↗

Revisions to the SRCC Rating Process for Solar Water Heaters: Preprint

In the United States, annual performance ratings for solar water heaters are computed with component-based simulation models driven by typical meteorological year weather and specified water draw. Changes in the process are being implemented to enhance credibility through increased transparency and accuracy. Changes to the process include using a graphical rather than text-based model-buildingtool, performing analytical tests on all components and systems, checking energy balances on every component, loop, and system at every time step, comparing the results to detect outliers and potential errors, and documenting the modeling process in detail. Examples of changes in ratings are shown, along with analytical and comparative testing results.

14 SOLAR ENERGY↗

Continuous operation of a coherent 3,000-qubit system

Neutral atoms are a promising platform for quantum science, enabling advances in areas ranging from quantum simulations and computation to metrology, atomic clocks and quantum networking. Although atom losses typically limit these systems to a pulsed mode, continuous operation could substantially enhance cycle rates, remove bottlenecks in metrology and enable deep-circuit quantum evolution through quantum error correction. Here we demonstrate an experimental architecture for high-rate reloading and continuous operation of a large-scale atom-array system while realizing coherent storage and manipulation of quantum information. Our approach utilizes a series of two optical lattice conveyor belts to transport atom reservoirs into the science region, where atoms are repeatedly extracted into optical tweezers without affecting the coherence of qubits stored nearby. Using a reloading rate of 300,000 atoms in tweezers per second, we create over 30,000 initialized qubits per second, which we leverage to assemble and maintain an array of over 3,000 atoms for more than 2 hours. Furthermore, we demonstrate persistent refilling of the array with atomic qubits in either a spin-polarized or a coherent superposition state while preserving the quantum state of stored qubits. Our results pave the way for the realization of large-scale continuously operated atomic clocks, sensors and fault-tolerant quantum computers.

atomic and molecular physics↗

Point Sensor Networks Struggle to Detect and Quantify Short Controlled Releases at Oil and Gas Sites

This study evaluated multiple commercially available continuous monitoring (CM) point sensor network (PSN) solutions under single-blind controlled release testing conducted at operational upstream and midstream oil and natural gas (O&G) sites. During releases, PSNs reported site-level emission rate estimates of 0 kg/h between 38 and 86% of the time. When non-zero site-level emission rate estimates were provided, no linear correlation between the release rate and the reported emission rate estimate was observed. The average, aggregated across all PSN solutions during releases, shows 5% of the mixing ratio readings at downwind sensors were greater than the site’s baseline plus two standard deviations. Four of seven total PSN solutions tested during this field campaign provided site-level emission rate estimates with the site average relative error ranging from −100% to 24% for solution D, −100% to −43% for solution E, −25% for solution F (solution F was only at one site), and −99% to 430% for solution G, with an overall average of −29% across all sites and solutions. Of all the individual site-level emission rate estimates, only 11% were within ±2.5 kg/h of the study team’s best estimate of site-level emissions at the time of the releases.

42 ENGINEERING↗

fPINNs: Fractional Physics-Informed Neural Networks

Physics-informed neural networks (PINNs), introduced, are effective in solving integer-order partial differential equations (PDEs) based on scattered and noisy data. PINNs employ standard feedforward neural networks (NNs) with the PDEs explicitly encoded into the NN using automatic differentiation, while the sum of the mean-squared PDE residuals and the mean-squared error in initial-boundary conditions is minimized with respect to the NN parameters. Here we extend PINNs to fractional PINNs (fPINNs) to solve space-time fractional advection-diffusion equations (fractional ADEs), and we study systematically their convergence, hence explaining both fPINNs and PINNs for the first time. Specifically, we demonstrate their accuracy and effectiveness in solving multidimensional forward and inverse problems with forcing terms whose values are only known at randomly scattered spatio-temporal coordinates (black-box (BB) forcing terms). A novel element of the fPINNs is the hybrid approach that we introduce for constructing the residual in the loss function using both automatic differentiation for the integer-order operators and numerical discretization for the fractional operators. This approach bypasses the difficulties stemming from the fact that automatic differentiation is not applicable to fractional operators because the standard chain rule in integer calculus is not valid in fractional calculus. To discretize the fractional operators, we employ the Grünwald--Letnikov (GL) formula in one-dimensional fractional ADEs and the vector GL formula in conjunction with the directional fractional Laplacian in two- and three-dimensional fractional ADEs. We first consider the one-dimensional fractional Poisson equation and compare the convergence of the fPINNs against the finite difference method (FDM). We present the solution convergence using both the mean L 2 error as well as the standard deviation due to sensitivity to NN parameter initializations. Using different GL formulas we observe first-, second-, and third-order convergence rates for small size training sets but the error saturates for larger training sets. We explain these results by analyzing the four sources of numerical errors due to discretization, sampling, NN approximation, and optimization. The total error decays monotonically (below 10 –5 for a third-order GL formula) but it saturates beyond that point due to the optimization error. We also analyze the relative balance between discretization and sampling errors and observe that the sampling size and the number of discretization points (auxiliary points) should be comparable to achieve the highest accuracy. As we increase the depth of the NN up to certain value, the mean error decreases and the standard deviation increases, whereas the width has essentially no effect unless its value is either too small or too large. We next consider time-dependent fractional ADEs and compare white-box (WB) and BB forcing. We observe that for the WB forcing, our results are similar to the aforementioned cases; however, for the BB forcing fPINNs outperform FDM. Subsequently, we consider multidimensional time-, space-, and space-time-fractional ADEs using the directional fractional Laplacian and we observe relative errors of 10 –3 ~ 10 –4 . Lastly, we solve several inverse problems in one, two, and three dimensions to identify the fractional orders, diffusion coefficients, and transport velocities and obtain accurate results given proper initializations even in the presence of significant noise.

97 MATHEMATICS AND COMPUTING↗

Development and evaluation of a new 4DEnVar-based weakly coupled ocean data assimilation system in E3SMv2

The development, implementation, and evaluation of a new weakly coupled ocean data assimilation (WCODA) system for the fully coupled Energy Exascale Earth System Model version 2 (E3SMv2) utilizing the four-dimensional ensemble variational (4DEnVar) method are presented in this study. The 4DEnVar method, based on the dimension-reduced projection four-dimensional variational (DRP-4DVar) approach, replaces the adjoint model with the ensemble technique, thereby reducing computational demands. Monthly mean ocean temperature and salinity data from the EN4.2.1 reanalysis are integrated into the ocean component of E3SMv2 from 1950 to 2021 with the goal of providing realistic initial conditions for decadal predictions and predictability studies. The performance of the WCODA system is assessed using various metrics, including the reduction rate of the cost function, root mean square error (RMSE) differences, correlation differences, and model biases. Results indicate that the WCODA system effectively assimilates the reanalysis data into the climate model, consistently achieving negative reduction rates of the cost function and notable improvements in RMSE and correlation across various ocean layers and regions. Significant enhancements are observed in the upper ocean layers across the majority of global ocean regions, particularly in the north Atlantic, north Pacific, and Indian Ocean. Model biases in sea surface temperature and salinity are also substantially reduced. For sea surface temperature, cold biases in the north Pacific and north Atlantic are diminished by about 1–2 °C, and warm biases in the Southern Ocean are corrected by approximately 1.5–2.5 °C. In terms of salinity, improvements are observed with bias reductions of about 0.5–1 psu in the north Atlantic and north Pacific and up to 1.5 psu in parts of the Southern Ocean. The ultimate goal of the WCODA system is to advance the predictive capabilities of E3SM for subseasonal to decadal climate predictions, thereby supporting research on strategic energy-sector policies and planning.

54 ENVIRONMENTAL SCIENCES↗

LDPC Codes with Minimum Distance Proportional to Block Size

Low-density parity-check (LDPC) codes characterized by minimum Hamming distances proportional to block sizes have been demonstrated. Like the codes mentioned in the immediately preceding article, the present codes are error-correcting codes suitable for use in a variety of wireless data-communication systems that include noisy channels. The previously mentioned codes have low decoding thresholds and reasonably low error floors. However, the minimum Hamming distances of those codes do not grow linearly with code-block sizes. Codes that have this minimum-distance property exhibit very low error floors. Examples of such codes include regular LDPC codes with variable degrees of at least 3. Unfortunately, the decoding thresholds of regular LDPC codes are high. Hence, there is a need for LDPC codes characterized by both low decoding thresholds and, in order to obtain acceptably low error floors, minimum Hamming distances that are proportional to code-block sizes. The present codes were developed to satisfy this need. The minimum Hamming distances of the present codes have been shown, through consideration of ensemble-average weight enumerators, to be proportional to code block sizes. As in the cases of irregular ensembles, the properties of these codes are sensitive to the proportion of degree-2 variable nodes. A code having too few such nodes tends to have an iterative decoding threshold that is far from the capacity threshold. A code having too many such nodes tends not to exhibit a minimum distance that is proportional to block size. Results of computational simulations have shown that the decoding thresholds of codes of the present type are lower than those of regular LDPC codes. Included in the simulations were a few examples from a family of codes characterized by rates ranging from low to high and by thresholds that adhere closely to their respective channel capacity thresholds; the simulation results from these examples showed that the codes in question have low error floors as well as low decoding thresholds. As an example, the illustration shows the protograph (which represents the blueprint for overall construction) of one proposed code family for code rates greater than or equal to 1.2. Any size LDPC code can be obtained by copying the protograph structure N times, then permuting the edges. The illustration also provides Field Programmable Gate Array (FPGA) hardware performance simulations for this code family. In addition, the illustration provides minimum signal-to-noise ratios (Eb/No) in decibels (decoding thresholds) to achieve zero error rates as the code block size goes to infinity for various code rates. In comparison with the codes mentioned in the preceding article, these codes have slightly higher decoding thresholds.

Divsalar, Dariush↗

The Earth's velocity for direct detection experiments

The Earth's velocity relative to the Sun in galactic coordinates is required in the rate calculation for direct detection experiments. We provide a rigorous derivation of this quantity to first order in the eccentricity of the Earth's orbit. We also discuss the effect of the precession of the equinoxes, which has hitherto received little explicit discussion. Comparing with other expressions in the literature, we confirm that the expression of Lee, Lisanti and Safdi is correct, while the expression of Lewin and Smith, the de facto standard expression, contains an error. For calculations of the absolute event rate, the leading order expression is sufficient while for modulation searches, an expression with the eccentricity is required for accurate predictions of the modulation phase.

79 ASTRONOMY AND ASTROPHYSICS↗

Technical Note: Contrast solution density and cross section errors in inhomogeneity-corrected dose calculation for breast balloon brachytherapy

Purpose: Recent recommendations by the American Association of Physicists in Medicine Task Group 186 emphasize the importance of understanding material properties and their effect on inhomogeneity-corrected dose calculation for brachytherapy. Radiographic contrast is normally injected into breast brachytherapy balloons. In this study, the authors independently estimate properties of contrast solution that were expected to be incorrectly specified in a commercial brachytherapy dose calculation algorithm. Methods: The mass density and atomic weight fractions of a clinical formulation of radiographic contrast solution were determined using manufacturers' data. The mass density was verified through measurement and compared with the density obtained by the treatment planning system's CT calibration. The atomic weight fractions were used to determine the photon interaction cross section of the contrast solution for a commercial high-dose-rate (HDR) brachytherapy source and compared with that of muscle. Results: The density of contrast solution was 10% less than that obtained from the CT calibration. The cross section of the contrast solution for the HDR source was 1.2% greater than that of muscle. Both errors could be addressed by overriding the density of the contrast solution in the treatment planning system. Conclusions: The authors estimate the error in mass density and cross section parameters used by a commercial brachytherapy dose calculation algorithm for radiographic contrast used in a clinical breast brachytherapy practice. This approach is adaptable to other clinics seeking to evaluate dose calculation errors and determine appropriate density override values if desired.

60 APPLIED LIFE SCIENCES↗

Ultimate wind sensing capabilities of the jimsphere and other rising balloon systems

The error in the magnitude of the horizontal wind field as computed for balloons with linear and quadratic rise rates ascending through a light, moderate, or severe wind field is derived. The rise rate function of the Jimsphere is analyzed as a special case. Figures are presented of wind error versus altitude for each rise rate and wind field, assuming linear smoothing. The ultimate capability of rising balloon systems for measuring wind from the surface to 18 kilometers can be determined from the data and the wind accuracy can be computed by knowing only the rise rate behavior versus altitude. The radii of smooth and roughened spheres needed to achieve the desired rise rate at various altitudes are derived. The radii for smooth and roughened balloons for tow-meter-per-second to 20-meter-per-second rise rates at 10 and 14 km altitudes, and the wind-following capability for each are tabulated.

Luers, J. K.↗

Dose Error Impacts on A Collection of Realistic Dose-Response Curves Based on A NASA Sonic Boom Community Noise Survey

The National Aeronautics and Space Administration (NASA) plans to conduct surveys of community response to quiet supersonic flight to collect dose-response data for international regulators. Previous models of noise dose versus annoyance response ignored uncertainty in the noise dose experienced by survey respondents. This dose error causes attenuation bias and results in inaccurate dose-response relationships. The impacts of dose errors can be explored by introducing error into the dose estimates of a simulated community noise survey. The simulated population annoyance response is determined by specific noise response characteristics, including the onset of annoyance intercept, rate of increasing annoyance, participant intercept variability, and response rates. This paper explores the effects of dose errors on notional populations created by perturbing the noise response characteristics observed in participants in a recent NASA flight test, QSF18. The QSF18-based population parameters were shifted up to ±20% to create the study populations. For the anticipated dose range of the X-59, changes to the onset of annoyance intercept have the greatest impact on erroneous model results. Quantifying point estimate errors illustrates the impact of dose error, with errors up to 14 dB observed for a fixed high annoyance percentage.

dose-response modeling↗