Search NASA⌕ Search

SEARCH · Search NASA

Results for “evaluation protocol”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,765 records · Page 98

Isotope ratio analysis of actinides, fission products, and geolocators by high-efficiency multi-collector thermal ionization mass spectrometry

A ThermoFisher 'Triton' multi-collector thermal ionization mass spectrometer (MC-TIMS) was evaluated for trace and ultra-trace level isotoperatioanalysis of actinides (uranium, plutonium, and americium), fission products and geolocators (strontium, cesium, and neodymium). Total efficiencies (atoms loaded to ions detected) of up to 0.5-2% for U, Pu, and Am, and 1-30% for Sr, Cs, and Nd can be reported employing resin bead load techniques onto flat ribbon Re filaments or resin beads loaded into a millimeter-sized cavity drilled into a Re rod. This results in detection limits of <0.1 fg (10{sup 4} atoms to 10{sup 5} atoms) for {sup 239-242+244}Pu, {sup 233+236}U, {sup 241-243}Am, {sup 89,90}Sr, and {sup 134,135,137}Cs, and {le} 1 pg for natural Nd isotopes (limited by the chemical processing blank) using a secondary electron multiplier (SEM) or multiple-ion counters (MICs). Relative standard deviations (RSD) as small as 0.1% and abundance sensitivities of 1 x 10{sup 6} or better using a SEM are reported here. Precisions of RSD {approx} 0.01-0.001% using a multi-collector Faraday cup array can be achieved at sub-nanogram concentrations for strontium and neodymium and are suitable to gain crucial geolocation information. The analytical protocols reported herein are of particular value for nuclear forensic and nuclear safeguard applications.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

SU-F-J-158: Respiratory Motion Resolved, Self-Gated 4D-MRI Using Rotating Cartesian K-Space Sampling

Purpose: Dynamic MRI has been used to quantify respiratory motion of abdominal organs in radiation treatment planning. Many existing 4D-MRI methods based on 2D acquisitions suffer from limited slice resolution and additional stitching artifacts when evaluated in 3D{sup 1}. To address these issues, we developed a 4D-MRI (3D dynamic) technique with true 3D k-space encoding and respiratory motion self-gating. Methods: The 3D k-space was acquired using a Rotating Cartesian K-space (ROCK) pattern, where the Cartesian grid was reordered in a quasi-spiral fashion with each spiral arm rotated using golden angle{sup 2}. Each quasi-spiral arm started with the k-space center-line, which were used as self-gating{sup 3} signal for respiratory motion estimation. The acquired k-space data was then binned into 8 respiratory phases and the golden angle ensures a near-uniform k-space sampling in each phase. Finally, dynamic 3D images were reconstructed using the ESPIRiT technique{sup 4}. 4D-MRI was performed on 6 healthy volunteers, using the following parameters (bSSFP, Fat-Sat, TE/TR=2ms/4ms, matrix size=500×350×120, resolution=1×1×1.2mm, TA=5min, 8 respiratory phases). Supplemental 2D real-time images were acquired in 9 different planes. Dynamic locations of the diaphragm dome and left kidney were measured from both 4D and 2D images. The same protocol was also performed on a MRI-compatible motion phantom where the motion was programmed with different amplitude (10–30mm) and frequency (3–10/min). Results: High resolution 4D-MRI were obtained successfully in 5 minutes. Quantitative motion measurements from 4D-MRI agree with the ones from 2D CINE (<5% error). The 4D images are free of the stitching artifacts and their near-isotropic resolution facilitates 3D visualization and segmentation of abdominal organs such as the liver, kidney and pancreas. Conclusion: Our preliminary studies demonstrated a novel ROCK 4D-MRI technique with true 3D k-space encoding and respiratory motion self-gating. The technique leads to high-resolution and artifacts-free 4D images for improved abdominal organ motion studies. K.S acknowledges funding support from NIH R01CA188300.

60 APPLIED LIFE SCIENCES↗

Yes, No, Maybe So: Human Factors Considerations for Fostering Calibrated Trust in Foundation Models Under Uncertainty

High-stakes analytical environments require analysts to evaluate evidence and generate conclusions to inform critical decisions often under conditions of uncertainty. Probabilistic decision-making based on incomplete or inaccurate information can reduce productivity, compromise national interests, and endanger public safety. Researchers are developing expert systems built on foundation models (FMs) to support analysts’ decision-making processes by enabling human-artificial intelligence (AI) teaming, in part through the quantification and expression of uncertainty information. As FMs continue to mature, it is imperative to correspondingly consider analysts’ needs for appropriately interpreting and using uncertainty information. However, prior research indicates that it remains unclear how analysts engage with FM-generated uncertainty information and the extent to which these interactions influence trust in, and reliance on, expert systems. We plan to review the state of the science and conduct an exploratory, qualitative study to (a) understand how properly communicated uncertainty can foster calibrated trust and appropriate reliance and (b) identify approaches for effectively conveying FM-generated uncertainty information during analytical workflows. We will administer semi-structured interviews with analysts from a specific high-stakes analytical environment to collect their current experiences with job-related uncertainty and their impressions when viewing FM-generated uncertainty information. During the interview protocol, participants will be presented with several different FM outputs and invited to discuss their thoughts and beliefs about the uncertainty information displayed. Participants may provide insights into how trust and reliance may be influenced by uncertainty. The results of this study will help us to better understand how analysts currently interpret and use uncertainty information. Our findings may inform human factors recommendations for effectively conveying uncertainty information to foster calibrated trust in, and appropriate reliance on, expert systems. Interaction designers and FM developers can use this knowledge to enhance human-AI teaming and ensure the responsible deployment of FM-based expert systems in analytical workflows.

97 MATHEMATICS AND COMPUTING↗

WE-AB-BRA-08: Results of a Multi-Institutional Study for the Evaluation of Deformable Image Registration Algorithms for Structure Delineation Via Computational Phantoms

Purpose: To investigate the accuracy of various algorithms for deformable image registration (DIR), to propagate regions of interest (ROIs) in computational phantoms based on patient images using different commercial systems. This work is part of an Italian multi-institutional study to test on common datasets the accuracy, reproducibility and safety of DIR applications in Adaptive Radiotherapy. Methods: Eleven institutions with three available commercial solutions provided data to assess the agreement of DIR-propagated ROIs with automatically drown ROIs considered as ground-truth for the comparison. The DIR algorithms were tested on real patient data from three different anatomical districts: head and neck, thorax and pelvis. For every dataset two specific Deformation Vector Fields (DVFs) provided by ImSimQA software were applied to the reference data set. Three different commercial software were used in this study: RayStation, Velocity and Mirada. The DIR-mapped ROIs were then compared with the reference ROIs using the Jaccard Conformity Index (JCI). Results: More than 600 DIR-mapped ROIs were analyzed. Putting together all JCI data of all institutions for the first DVF, the mean JCI was 0.87 ± 0.7 (1 SD) while for the second DVF JCI was 0.8 ± 0.13 (1 SD). Several considerations on different structures are available from collected data: the standard deviation among different institutions on specific structure raise as the larger is the applied DVF. The higher value is 10% for bladder. Conclusion: Although the complexity of deformation of human body is very difficult to model, this work illustrates some clinical scenarios with well-known DVFs provided by specific software. CI parameter gives the inter-user variability and may put in evidence the need of improving the working protocol in order to reduce the inter-institution JCI variability.

60 APPLIED LIFE SCIENCES↗

Assessment of task‐based performance from five clinical DBT systems using an anthropomorphic breast phantom

Purpose Digital breast tomosynthesis (DBT) is a limited‐angle tomographic breast imaging modality that can be used for breast cancer screening in conjunction with full‐field digital mammography (FFDM) or synthetic mammography (SM). Currently, there are five commercial DBT systems that have been approved by the U.S. FDA for breast cancer screening, all varying greatly in design and imaging protocol. Because the systems are different in technical specifications, there is a need for a quantitative approach for assessing them. In this study, the DBT systems are assessed using a novel methodology with an inkjet‐printed anthropomorphic phantom and four alternative forced choice (4AFC) study scheme. Method A breast phantom was fabricated using inkjet printing and parchment paper. The phantom contained 5‐mm spiculated masses fabricated with potassium iodide (KI)‐doped ink and microcalcifications (MCs) made with calcium hydroxyapatite. Images of the phantom were acquired on all five systems with DBT, FFDM, and SM modalities where available using beam settings under automatic exposure control. A 4AFC study was conducted to assess reader performance with each signal under each modality. Statistical analysis was performed on the data to determine proportion correct (PC), standard deviations, and levels of significance. Results For masses, overall detection was highest with DBT. The difference in PC was statistically significant between DBT and SM for most systems. A relationship was observed between increasing PC and greater gantry span. For MCs, performance was highest with DBT and FFDM compared to SM. The difference between PC of DBT and PC of SM was statistically significant for all manufacturers. Conclusions This methodology represents a novel approach for evaluating systems. This study is the first of its kind to use an inkjet‐printed anthropomorphic phantom with realistic signals to assess performance of clinical DBT imaging systems.

Ikejimba, Lynda C.↗

Procedure Parsing: A Method for Parsing Handwritten Documents into Computer-Based Procedures

The nuclear industry is heavily procedure driven, where almost everything has a step-by-step instruction that is expected to be followed in detail. Historically, these procedures were printed on paper copies. Recently, the industry transitioned towards electronic copies (i.e., PDFs on tablets). One major drive for this transition is the introduction of human error and loss of situation awareness when using paper copies. However, electronic copies of documents inherently have the same error traps as their paper cousins. Therefore, there is an increased interest in a way to utilize the information in the step-by-step guidance, but to present it in a dynamic manner that guides the user and adapts to any encountered conditions. Researchers at Idaho National Laboratory propose a flexible, automated method based on document parsing and augmented by natural language processing (NLP) techniques, to address these shortcomings and capitalize on these recent advancements in machine learning. The proposed method provides a cost-effective solution for computer-assisted procedure parsing of hand-written control room procedures, originally authored in Word or PDF formats, into instructions that can be displayed as computer-based procedures (CBP) in a modern graphical user interface. The researchers devised, implemented and demonstrated the Operating Procedure Extender for Novel Systems (OPENS) method in 2020. The key to OPENS is to map the original procedure text into a context-free grammar, tying content to equipment, locations, and other steps, actions, etc. This formal grammar is then used to isolate and define keywords and actions verbs, such as “measure” or “evaluate” and tie them to specific equipment referenced within that step or located in other steps, substeps, actions, subactions and tables throughout the procedure. OPENS generates an abstract syntax tree from the document which it uses to store a copy of this information in the open-standard, machine-readable and human-readable file formats XML and JSON. The XML is useful to preserve the relational aspects of the procedure for referencing tables and branching information so the user can be directed to the next appropriate active step based on the values entered for that step and previous steps. The JSON is useful for storing and exchanging data objects used to track responses to previous steps and state changes in simulated environments. In future iterations, these formats can also be used for storing more detailed information about input during plant operation or simulation. The techniques the researcher developed could further be improved by integration of recent advancements in machine learning. NLP methods could standardize documents, correct for grammatical error, and provide automated semantic validation. The researcher expects that self-supervised techniques applied to collections of natural language instructions could strengthen the model with broader context. All these methods together give us a practical way to automatically extract protocols from documents and user interactions, empowering researchers, procedure writers and nuclear operators while moving the industry forward.

99 GENERAL AND MISCELLANEOUS↗

Evaluation of Story Maps to Enhance Public Engagement and Communication at Legacy Management Sites - 17334

The US Department of Energy's Office of Legacy Management's (LM) mission is to fulfill the department's post-closure responsibilities and to ensure protection of human health and the environment. Accomplishing that mission currently requires managing 91 legacy sites across the country by performing efficient long-term surveillance and maintenance activities, preserving and making accessible historic site records, and identifying opportunities for beneficial reuse. Integral to the success of these activities is connecting and effectively communicating with the public, governments, and other interested parties. Relationships with such entities are so important that the Office of Legacy Management has elevated such engagement to one of its strategic goals for the next 10 years. Several public engagement efforts are currently supported, including stakeholder meetings, interpretive visitor centers, hard-copy documents, and Internet-based information sources. The tools available to communicate with the public via the Internet are continually improving, and LM proactively evaluates these tools to enhance public engagement. The use of ESRI Story Maps to effectively and more succinctly communicate LM's long-term surveillance and maintenance practices is one tool currently being evaluated. Story Maps can utilize multiple types of content to engage users through site narratives, illustrations of change over time, photos, videos, and embedded links to external sources of information. The ability to illustrate site complexities via graphics and geo-spatial data is particularly useful for staff as well as communicating to stakeholders. Staff with a variety of expertise and functions in the organization can be empowered to respond to stakeholder questions using this tool. In addition, Story Maps can be easily initiated and managed in real time by LM site managers, an efficiency that would be invaluable to them as immediate site communication needs arise. A series of test Story Maps for several sites were developed to explore the capabilities of the tool. The test Story Maps included pages that described site description and overview, historical conditions and use, cleanup conditions, current monitoring data if applicable, and institutional controls. Links to existing communications tools were also incorporated in Story Maps, such as existing web sites that currently store environmental reports and the Geo-spatial Environmental Mapping System (GEMS), where stakeholders can download monitoring data. As with any tool, many things must be taken into consideration, such as: 1) Can the current IT infrastructure support the tool? 2) What data quality protocols need to be established? 2) What resources will be needed to maintain this tool? 3) What type of information should be shared? 4) Who will be responsible for information updates? This paper explores potential approaches for developing and deploying this tool for the public. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Monte Carlo study of correction factors for the use of plastic phantoms in clinical electron dosimetry

In some recent dosimetry protocols, plastic is allowed as a phantom material for the determination of an absorbed dose to water in electron beams, especially for low energy with beam qualities R{sub 50}<4 g/cm{sup 2}. In electron dosimetry with plastic, a depth-scaling factor, c{sub pl}, and a chamber-dependent fluence correction factor, h{sub pl}, are needed to convert the dose measured at a water-equivalent reference depth in plastic to a dose at a reference depth in water. The purpose of this study is to calculate correction factors for the use of plastic phantoms for clinical electron dosimetry using the EGSnrc Monte Carlo code system. RMI-457 and WE-211 were investigated as phantom materials. First the c{sub pl} values for plastic materials were calculated as a function of a half-value depth of maximum ionization, I{sub 50}, in plastic. The c{sub pl} values for RMI-457 and WE-211 varied from 0.992 to 1.002 and from 0.971 to 0.979, respectively, in a range of nominal energies from 4 MeV to 18 MeV, and varied slightly as a function of I{sub 50} in plastic. Since h{sub pl} values depend on the wall correction factor, P{sub wall}, of the chamber used, they are evaluated using a pure electron fluence correction factor, {phi}{sub pl}{sup w}, and P{sub wall}{sup w} and P{sub wall}{sup pl} for a combination of water or plastic phantoms and plane-parallel ionization chambers (NACP-02, Markus and Roos). The {phi}{sub pl}{sup w} and P{sub wall} (P{sub wall}{sup w} and P{sub wall}{sup pl}) values were calculated as a function of the water-equivalent depth in plastic materials and at a reference depth as a function of R{sub 50} in water, respectively. The {phi}{sub pl}{sup w} values varied from 1.024 at 4 MeV to 1.013 at 18 MeV for RMI-457, and from 1.025 to 1.016 for WE-211. P{sub wall}{sup w} values for plane-parallel chambers showed values in the order of 1.5% to 2% larger than unity at 4 MeV, consistent with earlier results. The P{sub wall}{sup pl} values of RMI-457 and WE-211 were close to unity for all the energy beams. Finally, calculated h{sub pl} values of RMI-457 ranged from 1.009 to 1.005, from 1.010 to 1.003 and from 1.011 to 1.007 for NACP-02, Markus and Roos chambers, respectively, in the range of 4 MeV to 18 MeV, and the values of WE-211 were 1.010 to 1.004, 1.010 to 1.004 and 1.012 to 1.008, respectively. The calculated h{sub pl} values for the Markus chamber agreed within their combined uncertainty with the measured data.

61 RADIATION PROTECTION AND DOSIMETRY↗

Prediction of DVH parameter changes due to setup errors for breast cancer treatment based on 2D portal dosimetry

Electronic portal imaging devices (EPIDs) are increasingly used for portal dosimetry applications. In our department, EPIDs are clinically used for two-dimensional (2D) transit dosimetry. Predicted and measured portal dose images are compared to detect dose delivery errors caused for instance by setup errors or organ motion. The aim of this work is to develop a model to predict dose-volume histogram (DVH) changes due to setup errors during breast cancer treatment using 2D transit dosimetry. First, correlations between DVH parameter changes and 2D gamma parameters are investigated for different simulated setup errors, which are described by a binomial logistic regression model. The model calculates the probability that a DVH parameter changes more than a specific tolerance level and uses several gamma evaluation parameters for the planning target volume (PTV) projection in the EPID plane as input. Second, the predictive model is applied to clinically measured portal images. Predicted DVH parameter changes are compared to calculated DVH parameter changes using the measured setup error resulting from a dosimetric registration procedure. Statistical accuracy is investigated by using receiver operating characteristic (ROC) curves and values for the area under the curve (AUC), sensitivity, specificity, positive and negative predictive values. Changes in the mean PTV dose larger than 5%, and changes in V{sub 90} and V{sub 95} larger than 10% are accurately predicted based on a set of 2D gamma parameters. Most pronounced changes in the three DVH parameters are found for setup errors in the lateral-medial direction. AUC, sensitivity, specificity, and negative predictive values were between 85% and 100% while the positive predictive values were lower but still higher than 54%. Clinical predictive value is decreased due to the occurrence of patient rotations or breast deformations during treatment, but the overall reliability of the predictive model remains high. Based on our predictive model, 2D transit dosimetry measurements can now directly be translated in clinically more relevant DVH parameter changes for the PTV during conventional breast treatment. In this way, the possibility to design decision protocols based on extracted DVH changes is created instead of undertaking elaborate actions such as repeated treatment planning or 3D dose reconstruction for a large group of patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Detailed analysis of putative genes encoding small proteins in legume genomes

Diverse plant genome sequencing projects coupled with powerful bioinformatics tools have facilitated massive data analysis to construct specialized databases classified according to cellular function. However, there are still a considerable number of genes encoding proteins whose function has not yet been characterized. Included in this category are small proteins (SPs, 30–150 amino acids) encoded by short open reading frames (sORFs). SPs play important roles in plant physiology, growth, and development. Unfortunately, protocols focused on the genome-wide identification and characterization of sORFs are scarce or remain poorly implemented. As a result, these genes are underrepresented in many genome annotations. In this work, we exploited publicly available genome sequences of Phaseolus vulgaris, Medicago truncatula, Glycine max, and Lotus japonicus to analyze the abundance of annotated SPs in plant legumes. Our strategy to uncover bona fide sORFs at the genome level was centered in bioinformatics analysis of characteristics such as evidence of expression (transcription), presence of known protein regions or domains, and identification of orthologous genes in the genomes explored. We collected 6170, 10,461, 30,521, and 23,599 putative sORFs from P. vulgaris, G. max, M. truncatula, and L. japonicus genomes, respectively. Expressed sequence tags (ESTs) available in the DFCI Gene Index database provided evidence that ~one-third of the predicted legume sORFs are expressed. Most potential SPs have a counterpart in a different plant species and counterpart regions or domains in larger proteins. Potential functional sORFs were also classified according to a reduced set of GO categories, and the expression of 13 of them during P. vulgaris nodule ontogeny was confirmed by qPCR. This analysis provides a collection of sORFs that potentially encode for meaningful SPs, and offers the possibility of their further functional evaluation.

59 BASIC BIOLOGICAL SCIENCES↗

SU-C-207B-05: Tissue Segmentation of Computed Tomography Images Using a Random Forest Algorithm: A Feasibility Study

Purpose: Develop an automated Random Forest algorithm for tissue segmentation of CT examinations. Methods: Seven materials were classified for segmentation: background, lung/internal gas, fat, muscle, solid organ parenchyma, blood/contrast, and bone using Matlab and the Trainable Weka Segmentation (TWS) plugin of FIJI. The following classifier feature filters of TWS were investigated: minimum, maximum, mean, and variance each evaluated over a pixel radius of 2n, (n = 0–4). Also noise reduction and edge preserving filters, Gaussian, bilateral, Kuwahara, and anisotropic diffusion, were evaluated. The algorithm used 200 trees with 2 features per node. A training data set was established using an anonymized patient’s (male, 20 yr, 72 kg) chest-abdomen-pelvis CT examination. To establish segmentation ground truth, the training data were manually segmented using Eclipse planning software, and an intra-observer reproducibility test was conducted. Six additional patient data sets were segmented based on classifier data generated from the training data. Accuracy of segmentation was determined by calculating the Dice similarity coefficient (DSC) between manual and auto segmented images. Results: The optimized autosegmentation algorithm resulted in 16 features calculated using maximum, mean, variance, and Gaussian blur filters with kernel radii of 1, 2, and 4 pixels, in addition to the original CT number, and Kuwahara filter (linear kernel of 19 pixels). Ground truth had a DSC of 0.94 (range: 0.90–0.99) for adult and 0.92 (range: 0.85–0.99) for pediatric data sets across all seven segmentation classes. The automated algorithm produced segmentation with an average DSC of 0.85 ± 0.04 (range: 0.81–1.00) for the adult patients, and 0.86 ± 0.03 (range: 0.80–0.99) for the pediatric patients. Conclusion: The TWS Random Forest auto-segmentation algorithm was optimized for CT environment, and able to segment seven material classes over a range of body habitus and CT protocol parameters with an average DSC of 0.86 ± 0.04 (range: 0.80–0.99).

60 APPLIED LIFE SCIENCES↗

Iterative reconstruction for CT perfusion with a prior-image induced hybrid nonlocal means regularization: Phantom studies

Purpose: In computed tomography perfusion (CTP) imaging, an initial phase CT acquired with a high-dose protocol can be used to improve the image quality of later phase CT acquired with a low-dose protocol. For dynamic regions, signals in the later low-dose CT may not be completely recovered if the initial CT heavily regularizes the iterative reconstruction process. The authors propose a hybrid nonlocal means (hNLM) regularization model for iterative reconstruction of low-dose CTP to overcome the limitation of the conventional prior-image induced penalty. Methods: The hybrid penalty was constructed by combining the NLM of the initial phase high-dose CT in the stationary region and later phase low-dose CT in the dynamic region. The stationary and dynamic regions were determined by the similarity between the initial high-dose scan and later low-dose scan. The similarity was defined as a Gaussian kernel-based distance between the patch-window of the same pixel in the two scans, and its measurement was then used to weigh the influence of the initial high-dose CT. For regions with high similarity (e.g., stationary region), initial high-dose CT played a dominant role for regularizing the solution. For regions with low similarity (e.g., dynamic region), the regularization relied on a low-dose scan itself. This new hNLM penalty was incorporated into the penalized weighted least-squares (PWLS) for CTP reconstruction. Digital and physical phantom studies were performed to evaluate the PWLS-hNLM algorithm. Results: Both phantom studies showed that the PWLS-hNLM algorithm is superior to the conventional prior-image induced penalty term without considering the signal changes within the dynamic region. In the dynamic region of the Catphan phantom, the reconstruction error measured by root mean square error was reduced by 42.9% in PWLS-hNLM reconstructed image. Conclusions: The PWLS-hNLM algorithm can effectively use the initial high-dose CT to reconstruct low-dose CTP in the stationary region while reducing its influence in the dynamic region.

60 APPLIED LIFE SCIENCES↗

TH-C-18A-10: The Influence of Tube Current On X-Ray Focal Spot Size for 70 KV CT Imaging

Purpose: Focal spot blooming is an increase in the focal spot size at increased tube current and/or decreased tube potential. In this work, we evaluated the influence of tube current on the focal spot size at low kV for two CT systems, one of which used a tube designed to reduce blooming effects. Methods: A slit camera (10 micron slit) was used to measure focal spot size on two CT scanners from the same manufacturer (Siemens Somatom Force and Definition Flash) at 70 kV and low, medium and maximum tube currents, according to the capabilities of each system (Force: 100, 800 and 1300 mA; Flash: 100, 200 and 500 mA). Exposures were made with a stationary tube in service mode using a raised stand without table movement or flying focal spot technique. Focal spot size, nominally 0.8 and 1.2 mm, respectively, was measured parallel and perpendicular to the cathode-anode axis by calculating the full-width-at-half-maximum of the slit profile recording using computed radiographic plates. Results: Focal spot sizes perpendicular to the anode-cathode axis increased at the maximum mA by 5.7% on the Force and 39.1% on the Flash relative to that at the minimal mA, even though the mA was increased 13-fold on the Force and only 5- fold on the Flash. Focal spot size increased parallel to the anode-cathode axis by 70.4% on Force and 40.9% on Flash. Conclusion: For CT protocols using low kV, high mA is typically required. These protocols are relevant in children and smaller adults, and for dual-energy scanning. Technical measures to limit focal spot blooming are important in these settings to avoid reduced spatial resolution. The x-ray tube on a recently-introduced scanner appears to greatly reduce blooming effects, even at very high mA values. CHM has research support from Siemens Healthcare.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

OSI Passive Seismic Experiment at the Former Nevada Test Site

On-site inspection (OSI) is one of the four verification provisions of the Comprehensive Nuclear Test Ban Treaty (CTBT). Under the provisions of the CTBT, once the Treaty has entered into force, any signatory party can request an on-site inspection, which can then be carried out after approval (by majority voting) of the Executive Council. Once an OSI is approved, a team of 40 inspectors will be assembled to carry out an inspection to ''clarify whether a nuclear weapon test explosion or any other nuclear explosion has been carried out in violation of Article I''. One challenging aspect of carrying out an on-site inspection (OSI) in the case of a purported underground nuclear explosion is to detect and locate the underground effects of an explosion, which may include an explosion cavity, a zone of damaged rock, and/or a rubble zone associated with an underground collapsed cavity. The CTBT (Protocol, Section II part D, paragraph 69) prescribes several types of geophysical investigations that can be carried out for this purpose. One of the methods allowed by the CTBT for geophysical investigation is referred to in the Treaty Protocol as ''resonance seismometry''. This method, which was proposed and strongly promoted by Russia during the Treaty negotiations, is not described in the Treaty. Some clarification about the nature of the resonance method can be gained from OSI workshop presentations by Russian experts in the late 1990s. Our understanding is that resonance seismometry is a passive method that relies on seismic reverberations set up in an underground cavity by the passage of waves from regional and teleseismic sources. Only a few examples of the use of this method for detection of underground cavities have been presented, and those were done in cases where the existence and precise location of an underground cavity was known. As is the case with many of the geophysical methods allowed during an OSI under the Treaty, how resonance seismology really works and its effectiveness for OSI purposes has yet to be determined. For this experiment, we took a broad approach to the definition of ''resonance seismometry''; stretching it to include any means that employs passive seismic methods to infer the character of underground materials. In recent years there have been a number of advances in the use of correlation and noise analysis methods in seismology to obtain information about the subsurface. Our objective in this experiment was to use noise analysis and correlation analysis to evaluate these techniques for detecting and characterizing the underground damage zone from a nuclear explosion. The site that was chosen for the experiment was the Mackerel test in Area 4 of the former Nevada Test Site (now named the Nevada National Security Site, or NNSS). Mackerel was an underground nuclear test of less than 20 kT conducted in February of 1964 (DOENV-209-REV 15). The reason we chose this site is because there was a known apical cavity occurring at about 50 m depth above a rubble zone, and that the site had been investigated by the US Geological Survey with active seismic methods in 1965 (Watkins et al., 1967). Note that the time delay between detonation of the explosion (1964) and the time of the present survey (2010) is nearly 46 years - this would not be typical of an expected OSI under the CTBT.

58 GEOSCIENCES↗

Long-Term Results from Evaluation of Advanced New Construction Packages in Test Homes. Martha's Vineyard, Massachusetts

This report presents a cold climate project located in West Tisbury, Massachusetts, on the island of Martha’s Vineyard, that examines the relationships among very energy efficient single-family residential thermal enclosures, room-to-room temperature variations, and simplified space conditioning systems. Each of the four homes studied has a single ductless heat pump unit (DHU) located in the main living space and radiant electric resistance panels in each bedroom with individual thermostatic controls. Results indicate that temperature fluctuations in the living room due to aggressive setup and setback of the DHU may contribute to higher percentages of time where the bedroom temperatures were within +/-2°F of the living room temperatures. Solar gains in the living room, door opening/closure and occupant manipulation of thermostats appear to have had a significant impact on room-to-room temperature differences, as would be expected.

building energy optimization↗

Research on the IAEA State-Level Safeguards Approach in KAERI

The IAEA has verified the declared nuclear material according to the comprehensive safeguards agreement under NPT between the Republic of Korea and the IAEA, as well as the undeclared nuclear material and nuclear activities under the Additional Protocol. In the safeguards Implementation Report for 2007, the Agency drew a broader conclusion for Korea that all nuclear material has remained in peaceful activities in Korea because there was no indication of the diversion of declared nuclear material, and no indication of undeclared nuclear material and activities in the ROK. The IAEA also informed that the implementation of Integrated Safeguards (IS) in Korea started on 1 July, 2008 in accordance with the state level IS approach after a drawing of the broader conclusion. In addition, for now, a State-Level Safeguards Approach (SLA) is adopted for the ROK, including 11 Material Balance Areas (MBAs) in KAERI. This paper describes a comparison analysis between IS and SLA.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Whole-Pelvis or Bladder-Only Chemoradiation for Lymph Node-Negative Invasive Bladder Cancer: Single-Institution Experience

Purpose: Whole-pelvis (WP) concurrent chemoradiation (CCRT) is the standard bladder preserving option for patients with invasive bladder cancer. The standard practice is to treat elective pelvic lymph nodes, so our aim was to evaluate whether bladder-only (BO) CCRT leads to results similar to those obtained by standard WP-CCRT. Methods and Materials: Patient eligibility included histopathologically proven muscle-invasive bladder cancer, lymph nodes negative (T2-T4, N-) by radiology, and maximal transurethral resection of bladder tumor with normal hematologic, renal, and liver functions. Between March 2005 and May 2006, 230 patients were accrued. Patients were randomly assigned to WP-CCRT (120 patients) and BO-CCRT (110 patients). Data regarding the toxicity profile, compliance, initial complete response rates at 3 months, and occurrence of locoregional or distant failure were recorded. Results: With a median follow-up time of 5 years (range, 3-6), WP-CCRT was associated with a 5-year disease-free survival of 47.1% compared with 46.9% in patients treated with BO-CCRT (p = 0.5). The bladder preservation rates were 58.9% and 57.1% in WP-CCRT and BO-CCRT, respectively (p = 0.8), and the 5-year overall survival rates were 52.9% for WP-CCRT and 51% for BO-CCRT (p = 0.8). Conclusion: BO-CCRT showed similar rates of bladder preservation, disease-free survival, and overall survival rates as those of WP-CCRT. Smaller field sizes including bladder with 2-cm margins can be used as bladder preservation protocol for patients with muscle-invasive lymph node-negative bladder cancer to minimize the side effects of CCRT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quantum Networks for Resilient Power Grids: Theory and Simulated Evaluation

Quantum networks are considered the future of secure communication in the coming quantum era. Yet there lack significant efforts on developing practical quantum networks for power grids. Here, in this paper, we establish a quantum network-based power grid (QNetGrid) framework and develops a real-time, reliable, flexible, programmable, and cost-effective QNetGrid software testbed containing repeater-based quantum communication, quantum routing, real software-defined networking (SDN) switches, and real-time networked microgrids (NMs) operations. It makes the following contributions: 1) a repeater and routing based quantum network simulator (QNSim) is developed, 2) repeaters with and without quantum memories are respectively simulated in QNSim, 3) different routing scenarios in QNetGrid are investigated, 4) a real-time QNetGrid software testbed is built in RTDS incorporating QNSim and real SDN switches, and 5) various test cases are designed, and experimental results produced with the QNetGrid testbed provide valuable insights for building quantum networks in power grids.

24 POWER TRANSMISSION AND DISTRIBUTION↗