Search NASA⌕ Search

SEARCH · Search NASA

Results for “evaluation study”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,765 records · Page 98

Evaluating Retrieval Algorithm Climate Stability: Estimating 3D Optical Thickness Bias Distributions by Cloud Type

Detecting climate trends on large spatiotemporal scales requires accurate, stable measurements and stable retrieval algorithms. We strive to estimate how time-variant retrieval algorithm biases may impact trend detection. Here we focus on the 3D cloud optical thickness (τc) bias, which is among the largest in passive cloud retrieval algorithms. If this bias is time dependent, a possibility with potential decadal changes in cloud morphology, it may obscure genuine trends in τc. Although previous studies have evaluated the cloud- and sun-view geometry-dependent 3D τc bias on small spatial scales, before our current study none have evaluated the stability of this well-known bias on climate-relevant large spatiotemporal scales. These studies must estimate large scale distributions of the 3D τc bias by cloud type and estimate how cloud type amount may change between two climate states. We employ a novel approach to estimate large scale distributions of 3D τc using a proxy of the bias that quantifies the departure of clouds from satisfying the 1D radiative transfer assumption used in passive τc retrievals. This existing globally-distributed proxy is an angular consistency metric that was developed using fused Moderate-Resolution Imaging Spectroradiometer (MODIS) and Multi-angle Imaging Spectroradiometer (MISR) measurements. Calculating the 3D τc bias and the proxy, for known cloud fields enables us to establish statistical relationships between these two quantities, which can be used to calculate large-scale distributions of the 3D τc bias. This approach limits the number of 3D radiative transfer simulations required to only those needed to estimate a statistical relationship between the 3D τc bias for known cloud fields and a proxy of the bias. It is likely that future studies will be needed to evaluate retrieval algorithm bias stability for other geophysical variables as the community develops climate data records from satellite observations and their retrievals. This must be done in addition to monitoring and correcting measurement errors and uncertainties and understanding their impact on retrieved essential climate variables.

Yolanda Shea↗

Leveraging Large Language Models for Real-World Data Evidence: A Framework for Automated Treatment Extraction and Data Harmonization

Background: The ability to comprehensively collect treatment information from cancer patient medical records would enable studies to evaluate real-world benefits and risks tied to specific treatments. Currently, it is difficult to system- atically collect high-quality treatment information because it is often stored in unstructured text. Manually extracting and standardizing drug and regimen data is time-intensive. Recent advances in large language models (LLMs) offer a potential solution for automated extraction of structured treatment information from clinical text. Objective: This study systematically evaluates the utility of four LLMs from the Llama family for automated extraction of oncology treatment information from clinical text. This information can guide researchers using cancer registry data to provide insights into cancer care and outcomes beyond clinical trials. Methods: Four instruction-tuned Llama models with varying parameter counts (1B, 3B, 8B, and 70B) were evaluated for their ability to extract treatment information from clinical documents. A unified oncology knowledge base integrating seven major public data sources was developed to standardize and normalize extracted entities—a critical step for harmonizing data from diverse sources. Extracted treatment data were compared against expert-annotated ground truth. Model performance was assessed using accuracy metrics (Precision, Recall, F1-Score) and opera- tional feasibility metrics, including processing speed and structural compliance of the output. Results: A strong positive correlation was observed between model size and extraction accuracy. F1-score improved from 0.609 for the 1B model to 0.710 (3B), 0.807 (8B), and 0.828 (70B). While larger models demonstrated superior accuracy and compliance, they incurred higher computational costs. The modest performance difference between 8B and 70B suggests diminishing returns with increasing model size. Conclusions: LLMs represent a viable technology for automating oncology treatment extraction. The 8B-parameter model emerged as a highly effective option, balancing high accuracy and computational efficiency. Selecting an appropriate LLM for deployment in cancer registries involves a trade-off between desired accuracy and available operational resources. Harmonizing extracted entities with the oncology knowledge base facilitates standardized integration into common data models, enhancing data quality for real-world evidence analyses.

artificial intelligence↗

Data for A Hybrid Biophysical-Machine Learning Framework for Diurnal Surface Energy Flux Estimation Using Proximal Sensing

Thermal infrared-based remote sensing of surface energy fluxes has traditionally relied on high spatial resolution satellite data with revisit frequencies on the order of weeks. In this study, we evaluate a biophysics-based analytical surface energy balance model for predicting latent energy (LE) and sensible heat (H) fluxes using proximal sensing observations. The Surface Temperature Initiated Closure (STIC1.2) model has been extensively validated across a wide range of spatial and temporal scales using various satellite-derived thermal infrared data sets. Here we extend this validation by applying STIC at sub-hourly temporal resolution over multiple growing seasons for four distinct agricultural systems. We further develop and evaluate novel STIC variants that incorporate machine learning (ML) techniques to eliminate the need for surface energy balance observations, specifically net radiation and soil heat flux, thereby enhancing model applicability in data-sparse settings. The integration of a ML component to estimate surface available energy is shown to have strong predictive performance for both LE (R2 = 0.81–0.94) and H (R2 = 0.46–0.72) across all agricultural systems examined here, demonstrating the potential of hybrid biophysical-machine learning approaches for surface energy balance modeling with minimal data requirements. This study concludes with a novel application of explainable machine learning (exML) to diagnose sources of model error. This exML framework attributes residual prediction errors to both model input variables and environmental drivers not explicitly included in the simulation experiments. This approach provides a new pathway for improving model design and integrating previously overlooked yet influential variables into future model iterations.

AI/ML↗

Accuracy of Fukuoka and American Gastroenterological Association Guidelines for Predicting Advanced Neoplasia in Pancreatic Cyst Neoplasm: A Meta-Analysis

Background: A differential diagnosis of advanced pancreatic cystic neoplasms (PCNs) is critical to determine optimal treatment. The Fukuoka and American Gastroenterological Association (AGA) guidelines are the most widely accepted criteria for the management of PCNs. Objective: This study aimed to evaluate the diagnostic value of these guidelines in predicting advanced neoplasia (AN). Methods: A comprehensive electronic search of the PubMed, EMBASE, Web of Science, Cochrane Library, and Scopus databases was conducted to identify all relevant studies evaluating the Fukuoka and AGA guidelines in surgically resected and histologically confirmed PCNs. Pooled sensitivity, specificity, and diagnostic odds ratios (DORs) were calculated as compound measures of diagnostic accuracy using the random-effects model. Summary of receiver operating characteristic (SROC) curves and the area under the curve (AUC) were also performed. Results: A total of 21 studies with 3723 patients were included in this meta-analysis. Of these studies, 15, 4, and 2 evaluated the Fukuoka guidelines, the AGA guidelines, and both guidelines, respectively. For AN prediction, the Fukuoka guidelines had a pooled sensitivity of 0.67 (95% confidence interval [CI] 0.64–0.70), pooled specificity of 0.64 (95% CI 0.62–0.66), and pooled DOR of 6.28 (95% CI 4.38–9.01), with an AUC of the SROC of 0.78. AGA guidelines showed a pooled sensitivity of 0.59 (95% CI 0.52–0.65), pooled specificity of 0.77 (95% CI 0.74–0.80), and pooled DOR of 5.84 (95% CI 2.60–13.15), with an AUC of 0.79 (95% CI 0.70–0.88). Conclusion: When used alone, the Fukuoka and AGA guidelines showed similar but unsatisfactory diagnostic accuracy in the risk stratification of malignant potential of PCN. Thus, we recommend that they be applied only as a broad framework in clinical practice.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

An Examination of the Indiana State University Aerospace Administration Program

Declining enrollments in the Indiana State University (ISU) aerospace administration program prompted this case study. which evaluates the program in comparison with parallel programs at other universities, industry standards, and an independent audit. Survey instruments were administered to graduates, faculty, and employers for their views on competencies of an excellent aerospace administration program Results show the deficiency of the ISU program. Graduates, faculty, and employers rated all competencies-from moderate to considerable importance-similarly for an excellent program. Recommendations for program improvement were made, and suggestions for further research include studies to evaluate the effectiveness of a revised aerospace administration program.

Schwab, Gregory L.↗

SU-E-T-01: 2-D Characterization of DLG Among All MLC Leaf Pairs

Purpose: The aim of this study is to evaluate the variation of dosimetric leaf-gap (DLG) along the travel path of each MLC leaf pair. This study evaluates whether the spatial variations in DLG could cause dose differences between TPS-calculated and measured dose. Methods: The 6MV DLG values were measured for all leaf pairs in the direction of leaf motion using a 2-D diode array and 0.6cc ion chamber. These measurements were performed on two Varian Linacs, employing the Millennium 120-leaf MLC and a 2-D-DLG variation map was created via in-house software. Several test plans were created with sweeping MLC fields using constant gaps from 2mm to 10mm and corrected for 2-D variation utilizing in-house software. Measurements were performed utilizing the MapCHECK at 5.0cm depth for plans with and without the 2-D DLG correction and compared to the TPS calculated dose via gamma analysis (3%/3mm). Results: The measured DLGs for the middle 40 MLC leaf pairs (0.5cm width) were very similar along the central superior-inferior axis, with maximum variation of 0.2mm. The outer 20 MLC leaf pairs (1.0cm width) have DLG values from 0.32mm (mean) to 0.65mm (maximum) lower than the central leaf-pair, depending on off-axis distance. Gamma pass rates for the 2mm, 4mm, and 6mm sweep plans increased by 23.2%, 28.7%, and 26.0% respectively using the 2-D-DLG correction. The most improved dose points occur in areas modulated by the 1.0cm leaf-pairs. The gamma pass rate for the 10mm sweep plan increased by only 7.7%, indicating that the 2D variation becomes less significant for dynamic plans with larger MLC gaps. Conclusion: Fluences residing significantly off-axis with narrow sweeping gaps may exhibit significant variations from planned dose due to large differences between the true DLG exhibited by the 1.0cm leaf-pairs versus the constant DLG value utilized by the TPS for dose calculation.

60 APPLIED LIFE SCIENCES↗

Oxygen/hydrogen Space Station propulsion system concept definition for IOC

The potential for the reduction in propulsion system life cycle costs through the use of on-board water electrolysis to generate oxygen and hydrogen propellants, as well as the potential advantages of improved system safety and contamination impact, led to a study to evaluate candidate oxygen-/hydrogen-based propulsion systems. In this study a representative set of propulsion system requirements were compiled and candidate oxygen/hydrogen-based propulsion systems synthesized. These candidate concepts were screened and a systems evaluation was performed on the remaining eight candidate concepts. Detailed system schematics were prepared. Operational design conditions were determined and system weight, volume, energy requirements, and costs were calculated. Evaluation results indicated that the oxygen/hydrogen propulsion systems can provide simple, low cost, and viable systems for the IOC Space Station. Based on these data, a relative concept evaluation was conducted using as selection criteria reliability, safety, cost, technical risk, contamination, operational utility, growth potential, and integration potential. Top ranked candidate systems were recommended to NASA/MSFC for consideration for the IOC Space Station.

Shoji, J. M.↗

Twin Valve Caval Stent for Functional Replacement of Incompetent Tricuspid Valve: A Feasibility Animal Study

Objective: To evaluate feasibility of a twin valve caval stent (TVCS) for functional replacement of an incompetent tricuspid valve (TV) in an acute animal study. Methods: One swine and three sheep were used in the study. TVCS placement was tested in a swine with a normal TV. TVCS function was tested in three sheep with TV regurgitation created by papillary muscle avulsion. Cardiac angiograms and pressure measurements were used to evaluate TVCS function. Two sheep were studied after fluid overload. Results: TVCS was percutaneously placed properly at the central portions of the superior vena cava (SVC) and inferior vena cava (IVC) in the swine. Papillary muscle avulsion in three sheep caused significant tricuspid regurgitation with massive reflux into the right atrium (RA) and partial reflux into the SVC and IVC. TVCS placement eliminated reflux into the SVC and IVC. After fluid overload, there was enlargement of the right ventricle and RA and significant increase in right ventricle, RA, SVC, and IVC pressures, but no reflux into the IVC and SVC. Conclusion: The results of this feasibility study justify detailed evaluation of TVCS insertion for functional chronic replacement of incompetent TV.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Mesoscale Convective Systems Represented in High Resolution E3SMv2 and Impact of New Cloud and Convection Parameterizations

Mesoscale convective systems (MCSs) play an important role in modulating the global hydrological cycle, general circulation, and radiative energy budget. In this study, we evaluate MCS simulations in the second version of U.S. Department of Energy (DOE) Energy Exascale Earth System Model (E3SMv2). E3SMv2 atmosphere model (EAMv2) is run at the uniform 0.25? horizontal resolution. We track MCSs consistently in the model and observations using the PyFLEXTRKR algorithm, which defines MCS based on both cloud-top brightness temperature (Tb) and surface precipitation. Results from using Tb only to define MCS, commonly used in previous studies, are also discussed. Furthermore, sensitivity experiments are performed to examine the impact of new cloud and convection parameterizations developed for EAMv3 on simulated MCSs. Our results show that EAMv2 simulated MCS precipitation is largely underestimated in the tropics and contiguous United States. This is mainly attributed to the underestimated precipitation intensity in EAMv2. In contrast, the simulated MCS frequency becomes more comparable to observations if MCSs are defined only based on cloud-top Tb. The Tb-based MCS tracking method, however, includes many cloud systems with very weak precipitation which conflicts with the MCS definition. This result illustrates the importance of accounting for precipitation in evaluating simulated MCSs. We also find that the new physics parameterizations help increase the relative contribution of convective precipitation to total precipitation in the tropics, but the simulated MCS properties are generally not improved. This suggests that simulating MCSs will remain a challenge for the next version of E3SM.

Zhang, Meng↗

Analysis of the Touch-And-Go Surface Sampling Concept for Comet Sample Return Missions

This paper studies the Touch-and-Go (TAG) concept for enabling a spacecraft to take a sample from the surface of a small primitive body, such as an asteroid or comet. The idea behind the TAG concept is to let the spacecraft descend to the surface, make contact with the surface for several seconds, and then ascend to a safe location. Sampling would be accomplished by an end-effector that is active during the few seconds of surface contact. The TAG event is one of the most critical events in a primitive body sample-return mission. The purpose of this study is to evaluate the dynamic behavior of a representative spacecraft during the TAG event, i.e., immediately prior, during, and after surface contact of the sampler. The study evaluates the sample-collection performance of the proposed sampling end-effector, in this case a brushwheel sampler, while acquiring material from the surface during the contact. A main result of the study is a guidance and control (G&C) validation of the overall TAG concept, in addition to specific contributions to demonstrating the effectiveness of using nonlinear clutch mechanisms in the sampling arm joints, and increasing the length of the sampling arms to improve robustness.

Touch-and-Go (TAG)↗

Association of lead and cadmium exposure with frailty in US older adults

Background: Environmental lead and cadmium exposure is associated with higher risk of several age-related chronic diseases, including cardiovascular disease, chronic kidney disease and osteoporosis. These diseases may lead to frailty, a geriatric syndrome characterized by diminished physiologic reserve in multiple systems with decreased ability to cope with acute stressors. However, no previous study has evaluated the association between lead or cadmium exposure and frailty. Methods: Cross-sectional study among individuals aged ≥60 years who participated in the third U.S. National Health and Nutrition Examination Survey and had either blood lead (N=5272) or urine cadmium (N=4887) determinations. Frailty was ascertained with a slight modification of the Fried criteria, so that individuals meeting ≥3 of 5 pre-defined criteria (exhaustion, low body weight, low physical activity, weakness and slow walking speed), were considered as frail. The association between lead and cadmium with frailty was evaluated using logistic regression with adjustment for relevant confounders. Results: Median (intertertile range) concentrations of blood lead and urine cadmium were 3.9 µg/dl (2.9–4.9) and 0.62 µg/l (0.41–0.91), respectively. The prevalence of frailty was 7.1%. The adjusted odds ratios (95% confidence interval) of frailty comparing the second and third to the lowest tertile of blood lead were, respectively, 1.40 (0.96–2.04) and 1.75 (1.33–2.31). Lead concentrations were also associated with the frequency of exhaustion, weakness and slowness. The corresponding odds ratios (95% confidence interval) for cadmium were, respectively, 0.97 (0.68–1.39) and 1.55 (1.03–2.32), but this association did not hold after excluding participants with reduced glomerular filtration rate: 0.70 (0.43–1.14) and 1.09 (0.56–2.11), respectively. Conclusions: In the US older adult population, blood lead but not urine cadmium concentrations showed a direct dose–response relationship with frailty. These findings support that lead exposure increases frailty in older adults. - Highlights: • No previous study has evaluated the association between lead, cadmium and frailty. • In NHANES III, blood lead levels showed a dose–response relationship with frailty. • Lead was also associated with higher frequency of exhaustion, weakness and slowness. • For cadmium, the results did not support an overall association with frailty.

54 ENVIRONMENTAL SCIENCES↗

Investigating Benefits and Challenges of Converting Retiring Coal Plants into Nuclear Plants

A coal-to-nuclear (C2N) transition means siting a nuclear reactor at the site of a recently retired coal power plant. Three overarching questions from the C2N transition guide this research: where in the United States are retired coal facilities located and what factors make a site feasible for transition; what factors of technology, cost, and project timeline drive investor economics over such a decision; and how will C2N impact local communities? The study team evaluated the siting characteristics of recently retired plants and those operating coal-fired power plant sites run by a utility or an independent power producer utilizing publicly available data to screen U.S. coal power plant sites to nuclear-feasible locations. After screening all retired coal sites to a set of 157 potential candidates and screening operating sites to a set of 237 candidates, the study team estimates that 80% of retired and operating coal power plant sites that were evaluated have the basic characteristics needed to be considered amenable to host an advanced nuclear reactor. For the recently retired plant sites evaluated, this represents a capacity potential of 64.8 GWe to be backfit at 125 sites. For the operating plant sites evaluated, this represents a capacity potential of 198.5 GWe to be backfit at 190 sites. This report evaluates a case study for the detailed impacts and potential outcomes from a C2N transition. Based on the nuclear technology choices and sizes evaluated to replace a large coal plant of 1,200 MWe generation capacity at the case study site, nuclear overnight costs of capital could decrease by 15% to 35% when compared to a greenfield construction project, through the reuse of infrastructure from the coal facility. Nuclear replacement designs can have a lower capacity size because nuclear power plants run at higher capacity factors than coal power plants. In the case study replacing coal capacity with 924 GWe of nuclear capacity, the study team found regional economic activity could increase by as much as $\$275 million$ and add 650 new, permanent jobs to the region of analysis. The evaluated site choice in the report is hypothetical for analysis purposes only and based on available data and documented assumptions. Consequently, the findings only inform at a general level. A community, investor, or other interested stakeholder can use these results to set up a detailed, in-depth analysis for a specific application of interest, such as evaluating a C2N transition of a specific coal power plant and a specific nuclear technology design. The report was subjected to independent peer reviews by experts in systems engineering and regional economic modeling to evaluate analysis and assumptions.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Subtropical Eastern North Pacific SST bias in earth system models

Karthik Balaguru (PNNL), Luke Van Roekel (LLNL), L. Ruby Leung (PNNL) and Milena Veneziani (LLNL) Abstract: This study systematically evaluates the warm SST bias in the Subtropical Eastern North Pacific (SENP), a problem plaguing most CMIP6 models, using the Energy Exascale Earth System Model version 1 (E3SM). Compared to the model at its standard resolution (1o atmosphere, 30-60 km ocean), the SST bias improves in several regions at high resolution (0.25o atmosphere, 18-6 km ocean) except in subtropical eastern boundary regions, such as the SENP. A mixed layer heat budget analysis reveals that errors in the surface radiative fluxes and horizontal heat advection are primarily responsible for the bias. Analysis of HighResMIP models indicates that the lack of improvement in the SENP SST bias with resolution is not native to E3SM alone. A larger CMIP6 inter-model correlation of SST bias with biases in surface winds than radiation highlights the important role of large-scale circulation biases in the SENP SST bias in coupled models.

Balaguru, Karthik↗

Rational Design of a Multifunctional Binder for High-Capacity Silicon-Based Anodes

Although several principles have been recognized to fabricate a nominal "better" binder, there continues to be a lack of a rational design and synthesis approach that would meet the robust criteria required for silicon (Si) anodes. Herein, we report a synthetic polymer binder, i.e., catechol-functionalized chitosan cross-linked by glutaraldehyde (CS-CG+GA), that serves dual functionalities: (a) wetness-resistant adhesion capability via catechol grafting and (b) mechanical robustness via in situ formation of a three-dimensional (3D) network. A SiNP-based anode with a designed functional polymer network (CS-CG10%+6%GA) exhibits a capacity retention of 91.5% after 100 cycles (2144 +/- 14 mAh/g). Properties that are traditionally considered to be advantageous, including stronger adhesion strength and higher mechanical robustness, do not always improve the binder performance. A clear relationship between these properties and ultimate electrochemical performance is established by assessing the rheological behavior, mechanical property, adhesion force, peel stress, morphology evolution, and semiquantitative evaluation. This study provides a clear path for the rational design of high-performance functional polymer binders for not only Si-based electrodes but also other types of alloy and conversion-based electrodes.

Cao, Peng-Fei↗

A parametric evaluation of supersonic STOVL

This paper describes the results of a study to evaluate parametric variations to a single engine short-takeoff vertical-landing fighter/attack aircraft design. The variables considered involved thrust vectoring, thrust degradation, maximum lift, and other changes to determine the impact on short-takeoff performance, but subject to a vertical-landing capability. The results indicate that there are certain parameters that have a significant effect on short-field performance. Also, the optimal control strategies for transitions from a short-takeoff to forward flight and from forward flight to hover are determined. The results have applicability beyond the configuration evaluated.

Kidwell, G. H.↗

Visual detection of spatial contrast patterns: evaluation of five simple models

The ModelFest Phase One dataset is a collection of luminance contrast thresholds for 43 two-dimensional monochromatic spatial patterns confined to an area of approximately two by two degrees. These data were collected by a collaboration among twelve laboratories, and were designed to provide a common database for calibration and testing of spatial vision models. Here I report fits of the ModelFest data with five models: Peak Contrast, Contrast Energy, Generalized Energy, a Gabor Channels model, and a Discrete Cosine Transform model. The Gabor Channels model provides the best fit, though the other, simpler models, with the exception of Peak Contrast, provide remarkably good fits as well. Though there are clear individual differences, regularities in the data suggest the possibility of constructing a standard observer for spatial vision. c2000 Optical Society of America.

NASA Discipline Space Human Factors↗

Preemptive resource management for dynamically arriving tasks in an oversubscribed heterogeneous computing system

We design resource management heuristics that assign serial tasks to the nodes of a heterogeneous high performance computing (HPC) system. The value of completing these tasks is modeled using monotonically decreasing utility functions that represent the time-varying importance of the task. The value of completing a task is equal to its utility function at the time of its completion. The overall performance of this system is measured using the total utility earned by all tasks during some interval of time. To maximize the performance of such a system where the preemption of tasks is possible, we have designed, analyzed, and compared a set of resource allocation heuristic techniques. We combine two utility-aware heuristics with three different preemption techniques to create six preemption-capable heuristics. We also consider the two utility-aware heuristics without preemption. We use simulation studies to evaluate this set of eight heuristics and compare them with an FCFS heuristic, which is often used in real systems, and random assignments. In general, our set of eight heuristics is able to significantly outperform the comparison heuristics, and the preemption-capable heuristics are able to significantly increase the utility earned compared to the heuristics that do not use preemption. We analyze the performance tradeoffs among the different preemption-capable heuristics under a variety of oversubscribed workload environments.

97 MATHEMATICS AND COMPUTING↗

Evaluation of the Paratrend Multi-Analyte Sensor for Potential Utilization in Long-Duration Automated Cell Culture Monitoring

BACKGROUND: Compact and automated sensors are desired for assessing the health of cell cultures in biotechnology experiments. While several single-analyte sensors exist to measure culture health, a multi-analyte sensor would simplify the cell culture system. One such multi-analyte sensor, the Paratrend 7 manufactured by Diametrics Medical, consists of three optical fibers for measuring pH, dissolved carbon dioxide (pCO(2)), dissolved oxygen (pO(2)), and a thermocouple to measure temperature. The sensor bundle was designed for intra-vascular measurements in clinical settings, and can be used in bioreactors operated both on the ground and in NASA's Space Shuttle and International Space Station (ISS) experiments. METHODS: A Paratrend 7 sensor was placed at the outlet of a bioreactor inoculated with BHK-21 (baby hamster kidney) cells. The pH, pCO(2), pO(2), and temperature data were transferred continuously to an external computer. Cell culture medium, manually extracted from the bioreactor through a sampling port, was also assayed using a bench top blood gas analyzer (BGA). RESULTS: Two Paratrend 7 sensors were used over a single cell culture experiment (64 days). When compared to the manually obtained BGA samples, the sensor had good agreement for pH, pCO(2), and pO(2) with bias (and precision) 0.005(0.024), 8.0 mmHg (4.4 mmHg), and 11 mmHg (17 mmHg), respectively for the first two sensors. A third Paratrend sensor (operated for 141 days) had similar agreement (0.02+/-0.15 for pH, -4+/-8 mm Hg for pCO(2), and 24+/-18 mmHg for pO(2)). CONCLUSION: The resulting biases and precisions are com- parable to Paratrend sensor clinical results. Although the pO(2) differences may be acceptable for clinically relevant measurement ranges, the O(2) sensor in this bundle may not be reliable enough for the ranges of pO(2) in these cell culture studies without periodic calibration.

Validation Studies↗