Search NASA⌕ Search

SEARCH · Search NASA

Results for “failure analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,765 records · Page 98

MR elastography of liver at 3 Tesla: comparison of gradient-recalled echo (GRE) and spin-echo (SE) echo-planar imaging (EPI) sequences and agreement across stiffness measurements

Purpose: To compare 2D gradient-recalled echo (GRE) and 2D spin-echo (SE) echo-planar imaging (EPI) MR elastography (MRE) for measurement of hepatic stiffness in adult patients with known or suspected liver disease at 3 Tesla. Materials and methods: Three hundred and eighty-seven consecutive patients underwent MRE of the liver at 3 Tesla with 2D-GRE and 2D-SE-EPI sequences. ‘Mean liver stiffness (LS)’ calculated by averaging 3 ROIs in the right lobe, ‘Maximum LS’ calculated by an ROI in the right lobe; and ‘Freehand LS’ calculated by an ROI in the entire liver were measured by two independent readers. Inter-observer and inter-class variability in stiffness measurements were assessed. Stiffness values were correlated with degree of liver fibrosis (METAVIR scores) in 97 patients who underwent biopsy. The diagnostic performance was compared by a receiver-operating characteristic analysis. Results: The technical failure rate was 2.8% for 2D-SE-EPI (11/387) and 4.1% for 2D-GRE (16/387, 9 had R{sub 2}* > 80 s{sup −1} indicating iron overload). There is high reproducibility for both GRE and SE-EPI variants (ICC = 0.84–0.94 for both GRE and SE-EPI MRE). The highest sensitivity, specificity, and accuracy of differentiating mild fibrosis (F0–F2) from advanced fibrosis (F3–F4) are 0.84 (GRE Freehand measurement), 0.92 (GRE Maximum stiffness measurement), and 0.88 (GRE Freehand measurement), respectively. Conclusions: High intra-class correlation and intra-reader correlation are seen on measured hepatic stiffness for both 2D-GRE and 2D-SE-EPI MRE. 2D-SE-EPI has lower failure rate. Diagnostic performance of both sequences is equivalent, with highest sensitivity for 2D-GRE Freehand stiffness measurement, and highest specificity 2D-GRE Maximum stiffness measurement.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Mechanistic understanding of aging behaviors of critical-material-free Li 4 Ti 5 O 12 //LiNi 0.9 Mn 0.1 O 2 cells with fluorinated carbonate-based electrolytes for safe energy storage with ultra-long life span

Behind-the-meter storage (BTMS) systems - a viable method to minimize potential risk of blackout events and stabilize the grid - require a different type of cost-effective energy storage with excellent safety, ultra-long (>20 years) cycle life and reasonable energy density compared that of electric vehicles. To increase the energy density and reduce the cost of a long-term cyclable lithium-titanate-based cell, it is required to employ a critical-material-free high voltage cathode and an electrolyte with good electrochemical and transport properties. In this report the long-term electrochemical performance and behaviors of selected critical-material-free Li 4 Ti 5 O 12 (LTO)//LiNi 0.9 Mn 0.1 O 2 (LNMO) full cells for BTMS applications are evaluated and analyzed in the optimized voltage range of 1.4-2.7 V at 45 degrees C with different fluorinated carbonate-based electrolytes. The fluoroethylene carbonate (FEC)-based electrolyte cell shows the highest capacity retention of 57.9% and Coulombic efficiency (CE) of 99.96% after 1000 cycles, potentially attributed to a dense, homogenous and less resistive LiF-rich solid-electrolyte interphase (SEI) layer formed on the surface of LTO that may mitigate electrolyte decomposition and maintain relatively low cell impedance during cycling. The 3,3,3-fluoroethylmethyl carbonate (F-EMC)-based electrolyte cell, however, presents the worst performance with lower capacity and a sharp decrease of CE, due to unstable and non-uniform SEI formation and continuous oxidative electrolyte decomposition. This mechanistic understanding of cell aging behaviors and failure mechanisms with detailed analysis of surface chemistry and electrode morphology can guide design of new electrode chemistries and electrolyte formulations for the development of BTMS batteries.

25 ENERGY STORAGE↗

THE DEVELOPMENT OF MICROSTRUCTURAL DAMAGE DURING HIGH TEMPERATURE CREEP-FATIGUE OF A NICKEL ALLOY

Alloy 617 is the leading candidate material for an Intermediate Heat Exchanger (IHX) of the Very High Temperature Reactor (VHTR). To evaluate the behavior of this material in the expected service conditions, strain-controlled cyclic tests that include hold times up to 9000 s at maximum tensile strain were conducted at 950 degrees C. The fatigue resistance decreased when a hold time was added at peak tensile strain, owing to the mechanisms resulting in a change in fracture mode from transgranular in pure fatigue to intergranular in creep–fatigue. Increases in the tensile hold duration beyond an initial value were not detrimental to the creep–fatigue resistance. An analysis of the evolving failure modes was facilitated by interrupting tests during cycling for ex situ microstructural investigation.

36 MATERIALS SCIENCE↗

Modeling and Characterization of Dynamic Failure of Borosilicate Glass under Compression/Shear Loading

In this paper, we study the impact-induced dynamic failure of a borosilicate glass block using an integrated experimental/analytical approach. Previous experimental studies on dynamic failure of borosilicate glass have been reported by Nie et al.1 using the Split Hopkinson Pressure Bar (SHPB) technique. The damage growth patterns and stress histories have been reported for various glass specimen designs. In this study, we propose to use a continuum damage mechanics (CDM)-based constitutive model to describe the initial failure and subsequent stiffness reduction of glass. Explicit finite element analyses are used to simulate the glass specimen impact event. A maximum shear stress-based damage evolution law is used in describing the glass damage process under combined compression/shear loading. The impact test results are used in quantifying the critical shear stress for the borosilicate glass under examination. It is shown that with only two modeling parameters, reasonably good comparisons between the predicted and the experimentally measured failure maps can be obtained for various glass sample geometries. Comparisons between the predicted stress histories for different sample designs are also used as model validations.

36 MATERIALS SCIENCE↗

Non-invasive measurement of proppant pack deformation

In this study, we describe a method to non-invasively study the movement of proppant packs at the sub-fracture scale by applying three-dimensional digital image correlation techniques to X-ray tomography data. Proppant movement is tracked in a fractured core of Marcellus shale placed under a series of increasing confining pressures up to 10,000 psi. The analysis reveals the sudden failure of a region of the proppant pack, accompanied by the large-scale rearrangement of grains across the entire fracture surface. The failure of the pack coincides with the appearance of vortex-like grain motions similar to features observed in biaxial compression of two dimensional granular assemblies.

02 PETROLEUM↗

Selective Nodal Irradiation for Head and Neck Cancer Using Intensity-Modulated Radiotherapy: Application of RTOG Consensus Guidelines in Routine Clinical Practice

Purpose: We have been using intensity-modulated radiotherapy (IMRT) for selective neck irradiation. This article presents an analysis of patterns of failure and their dosimetric correlation. Methods and Materials: Between October 2003 and January 2008, 83 patients with head-and-neck cancer were treated with IMRT. Nodal levels were contoured as per the Radiation Therapy Oncology Group (RTOG) consensus guidelines. Results: There were 32 relapses with 23 local relapses (21 local relapses alone and 2 local and regional relapses, simultaneously), 9 regional relapses (including 2 simultaneous local and regional relapses), and 5 distant relapses, of which 2 patients had local relapses. At 2 and 3 years, the locoregional relapse-free survival rates were was 68.3% and 60.8%, respectively, while the overall survival rates were 84.1% and 81.7%, respectively. Subgroup analyses revealed significant differences in locoregional relapse-free survival rates for total treatment times of <53 days vs. >53 days, a volume of CTV1PTV (i.e., the volume prescribed 70 Gy) <177 cc vs. >177 cc, a V100 for CTV1PTV of <91% vs. >91%, and a minimum dose to CTV1PTV of <54 Gy vs. >54 Gy. There were no failures in the elective nodal volume, substantiating both the nodal selection criteria and the RTOG consensus guidelines for delineation of neck node levels. Conclusions: IMRT for head-neck cancer is feasible, using elective nodal selection criteria along with RTOG consensus guidelines for the radiological boundaries of levels of neck nodes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Postoperative Chemoradiotherapy for Extrahepatic Bile Duct Cancer

Purpose: To evaluate the effect of postoperative concurrent chemoradiotherapy using three-dimensional conformal radiotherapy and to identify the prognostic factors that influence survival in patients with extrahepatic bile duct cancer. Methods and Materials: We retrospectively analyzed the data from 101 patients with extrahepatic bile duct cancer who had undergone postoperative concurrent chemoradiotherapy using three-dimensional conformal radiotherapy. Of the 101 patients, 52 (51%) had undergone complete resection (R0 resection) and 49 (49%) had microscopic or macroscopic residual tumors (R1 or R2 resection). The median radiation dose was 50 Gy. Also, 85 patients (84%) underwent concurrent chemotherapy with 5-fluorouracil. Results: The median follow-up period was 47 months for the surviving patients. The 5-year overall survival rate was 34% for all patients. A comparison between patients with R0 and R1 resection indicated no significant difference in the 5-year overall survival (44% vs. 33%, p = .2779), progression-free survival (35% vs. 22%, p = .3107), or locoregional progression-free survival (75% vs. 63%, p = .2784) rates. An analysis of the first failure site in the 89 patients with R0 or R1 resection indicated isolated locoregional recurrence in 7 patients. Elevated postoperative carbohydrate antigen 19-9 level was an independent prognostic factor for overall survival (p = .001) and progression-free survival (p = .033). A total of 3 patients developed Grade 3 or greater late toxicity. Conclusion: Adjuvant concurrent chemoradiotherapy using three-dimensional conformal radiotherapy appears to improve locoregional control and survival in extrahepatic bile duct cancer patients with R1 resection. The postoperative carbohydrate antigen 19-9 level might be a useful prognostic marker to select patients for more intensified adjuvant therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Experimental studies on eutectic formation between metallic fuel and HT-9M cladding in a single-pin core structure of a sodium-cooled fast reactor

Metallic fuel relocation experiments were conducted in which molten uranium was dropped into the cladding of a single fuel pin where eutectic interaction between fuel and cladding led to the release of eutectic fuel mixture into a narrow sodium channel. The thermal hydraulic relocation behavior of the molten uranium was analyzed in a previous study. Here, the extent of the eutectic formation was evaluated by scanning electron microscopy and energy-dispersive spectroscopy (SEM/EDS). The SEM/EDS analysis confirmed that cladding failure was caused by eutectic penetration. The eutectic penetration initiated around the boundary between cladding and uranium fuel, progressed into the cladding, and caused the cladding failure. Near the cladding failure region, the original cladding shape was unrecognizable, and many cracks, breakthroughs, and partial losses of the cladding were observed. The main components of the cladding failure region were UFe2 and U6Fe, which are the key components in the eutectic penetration

Eutectic Penetration↗

A review for identification of initiating events in event tree development process on nuclear power plants

Initiating event is defined as any event either internal or external to the nuclear power plants (NPPs) that perturbs the steady state operation of the plant, if operating, thereby initiating an abnormal event such as transient or loss of coolant accident (LOCA) within the NPPs. These initiating events trigger sequences of events that challenge plant control and safety systems whose failure could potentially lead to core damage or large early release. Selection for initiating events consists of two steps i.e. first step, definition of possible events, such as by evaluating a comprehensive engineering, and by constructing a top level logic model. Then the second step, grouping of identified initiating event's by the safety function to be performed or combinations of systems responses. Therefore, the purpose of this paper is to discuss initiating events identification in event tree development process and to reviews other probabilistic safety assessments (PSA). The identification of initiating events also involves the past operating experience, review of other PSA, failure mode and effect analysis (FMEA), feedback from system modeling, and master logic diagram (special type of fault tree). By using the method of study for the condition of the traditional US PSA categorization in detail, could be obtained the important initiating events that are categorized into LOCA, transients and external events.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Transition among failure modes of the bending system with a stiff film on a soft substrate

Growing interest is being attracted by stretchable and flexible electronics recently due to their attractive characteristics, commercial potentials, and engineering challenges. In comparison with the system on a macroscopic scale, different failure modes are observed in a system with a thin film bonded on an elastomeric substrate. Furthermore, the experimental observations reveal that failure modes occur in turn with the increasing of thickness ratio of the film to substrate. In this paper, theoretical analysis is performed on the failure mechanism in this system with the focus on transitions among these failure modes based on the theory of fracture mechanics. The present theoretical predictions are coincident with related experiment results and can be used to guide the related structural design.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Communication: xDH double hybrid functionals can be qualitatively incorrect for non-equilibrium geometries: Dipole moment inversion and barriers to radical-radical association using XYG3 and XYGJ-OS

Here, double hybrid (DH) density functionals are amongst the most accurate density functional approximations developed so far, largely due to the incorporation of correlation effects from unoccupied orbitals via second order perturbation theory (PT2). The xDH family of DH functionals calculate energy directly from orbitals optimized by a lower level approach like B3LYP, without self-consistent optimization. XYG3 and XYGJ-OS are two widely used xDH functionals that are known to be quite accurate at equilibrium geometries. Here, we show that the XYG3 and XYGJ-OS functionals can be ill behaved for stretched bonds well beyond the Coulson-Fischer point, predicting unphysical dipole moments and humps in potential energy curves for some simple systems like the hydrogen fluoride molecule. Numerical experiments and analysis show that these failures are not due to PT2. Instead, a large mismatch at stretched bond-lengths between the reference B3LYP orbitals and the optimized orbitals associated with the non-PT2 part of XYG3 leads to an unphysically large non-Hellman-Feynman contribution to first order properties like forces and electron densities.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development of FPGA-based multi-sensor excitation low voltage (MSELV) chassis at Jefferson Lab

The design and development of the sensor excitation and read back chassis was driven by the requirements for the monitoring and control of two conduction-cooled superconducting magnets in Hall B for the 12 GeV accelerator upgrade. The torus and solenoid superconducting magnets require extensive instrumentation. Sensor selection was accomplished by applying Jefferson Lab’s (JLab) risk mitigation process, which employed a failure modes and effects analysis approach. The goal was to accommodate all sensor types for monitoring and control and to develop a generic multisensor excitation low voltage chassis that would be used across both magnet systems with a reduced set of functions. As a result, the chassis has been deployed in experimental Hall B at JLab and has been performing successfully since July 2016.

47 OTHER INSTRUMENTATION↗

Amorphous layer coating induced brittle to ductile transition in single crystalline SiC nanowires: an atomistic simulation

Molecular dynamics simulations with Tersoff potentials were used to study the response of SiC nanowires with and without amorphous coating to a tensile strain along the axial direction. The uncoated nanowires show brittle properties and fail through bond breaking. Although the amorphous coating leads to the decrease of Young’s modulus of nanowires, yet it also leads the appearance of plastic deformation under axial strain. These results provide an effective way to modify the brittle properties of some other semiconductor nanowires.

36 MATERIALS SCIENCE↗

Instrumentation and Control Selection for the 12 GeV Hall-B Magnets at Jefferson Lab

Here, as part of the Jefferson Lab 12 GeV accelerator upgrade, the Experimental Physics Hall B detector system requires two superconducting magnets – a Torus and a Solenoid. The specifications required maximum space for the detectors which led to the choice of conduction cooling for each magnet. The Torus consists of 6 trapezoidal 'race-track'-type coils connected in series with an operating current of 3770 A. The Solenoid is an actively shielded 5 Tesla magnet consisting of 5 coils connected in series operating at 2416 A. Within the hall the two magnets are located in close proximity to each other and are surrounded by particle detectors. We describe the philosophy behind the instrumentation selection and control design that accounts for this proximity and other challenging working conditions. We describe the choice of sensor technologies, as well as the control and data acquisition methods. The magnet power and cryogenic control sub-systems are implemented using Allen Bradley Control Logix 1756-L72 Programmable Logic Controllers. Sensor instrumentation read-backs are routed into the PLC via National Instruments cRIO hardware (Field Programmable Gate Arrays or FPGA/RT application) using Jefferson Lab designed FPGA-based multi-sensor-excitation-chassis. Configuration, monitoring, and alarm handlers for the magnet systems are provided via an Experimental Physics Instrumentation & Control System interface (EPICS). Failure Modes and Effects Analysis (FMEA) and the requirement to monitor critical parameters during operation guided the selection of instrumentation and associated hardware. The design of the quench protection and voltage tap sub-systems was driven by the anticipated level of voltages developed during a magnet quench. The primary hard-wired quench detection and protection sub-system together with the secondary PLC-based protection sub-system is also discussed. The successful commissioning and subsequent performance of these magnets demonstrates the robustness of the design and implementation approach that was adopted by the Jefferson Lab team and serves as an excellent 'How To' guide for future projects of this size and complexity.

12 GeV↗

Superconducting Magnet Power Supply and Hard-Wired Quench Protection at Jefferson Lab for 12 GeV Upgrade

The superconducting magnet system in Hall B being designed and built as part of the Jefferson Lab 12 GeV upgrade requires powering two conduction cooled superconducting magnets - a torus and a solenoid. The torus magnet is designed to operate at 3770 A and solenoid at 2416 A. Failure Modes and Effects Analysis (FMEA) determined that voltage level thresholds and dump switch operation for magnet protection should be tested and analyzed before incorporation into the system. The designs of the quench protection and voltage tap sub-systems were driven by the requirement to use a primary hard-wired quench detection sub-system together with a secondary PLC-based protection. Parallel path voltage taps feed both the primary and secondary quench protection sub-systems. The PLC based secondary protection is deployed as a backup for the hard-wired quench detection sub-system and also acts directly on the dump switch. Here, we describe a series of tests and modifications carried out on the magnet power supply and quench protection system to ensure that the superconducting magnet is protected for all fault scenarios.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

SU-F-T-163: Improve Proton Therapy Efficiency: Report of a Workshop

Purpose: The technology of proton therapy, especially the pencil beam scanning technique, is evolving very quickly. However, the efficiency of proton therapy seems to lag behind conventional photon therapy. The purpose of the abstract is to report on the findings of a workshop on improvement of QA, planning and treatment efficiency in proton therapy. Methods: A panel of physicists, clinicians, and vendor representatives from over 18 institutions in the United States and internationally were convened in Knoxville, Tennessee in November, 2015. The panel discussed several topics on how to improve proton therapy efficiency, including 1) lean principle and failure mode and effects analysis, 2) commissioning and machine QA, 3) treatment planning, optimization and evaluation, 4) patient positioning and IGRT, 5) vendor liaison and machine availability, and 6) staffing, education and training. Results: The relative time needed for machine QA, treatment planning & check in proton therapy was found to range from 1 to 2.5 times of that in photon therapy. Current status in proton QA, planning and treatment was assessed. Key areas for efficiency improvement, such as elimination of unnecessary QA items or steps and development of efficient software or hardware tools, were identified. A white paper to summarize our findings is being written. Conclusion: It is critical to improve efficiency by developing reliable proton beam lines, efficient software tools on treatment planning, optimization and evaluation, and dedicated proton QA device. Conscious efforts and collaborations from both industry leaders and proton therapy centers are needed to achieve this goal and further advance the technology of proton therapy.

60 APPLIED LIFE SCIENCES↗

WE-B-BRC-00: Concepts in Risk-Based Assessment

Prospective quality management techniques, long used by engineering and industry, have become a growing aspect of efforts to improve quality management and safety in healthcare. These techniques are of particular interest to medical physics as scope and complexity of clinical practice continue to grow, thus making the prescriptive methods we have used harder to apply and potentially less effective for our interconnected and highly complex healthcare enterprise, especially in imaging and radiation oncology. An essential part of most prospective methods is the need to assess the various risks associated with problems, failures, errors, and design flaws in our systems. We therefore begin with an overview of risk assessment methodologies used in healthcare and industry and discuss their strengths and weaknesses. The rationale for use of process mapping, failure modes and effects analysis (FMEA) and fault tree analysis (FTA) by TG-100 will be described, as well as suggestions for the way forward. This is followed by discussion of radiation oncology specific risk assessment strategies and issues, including the TG-100 effort to evaluate IMRT and other ways to think about risk in the context of radiotherapy. Incident learning systems, local as well as the ASTRO/AAPM ROILS system, can also be useful in the risk assessment process. Finally, risk in the context of medical imaging will be discussed. Radiation (and other) safety considerations, as well as lack of quality and certainty all contribute to the potential risks associated with suboptimal imaging. The goal of this session is to summarize a wide variety of risk analysis methods and issues to give the medical physicist access to tools which can better define risks (and their importance) which we work to mitigate with both prescriptive and prospective risk-based quality management methods. Learning Objectives: Description of risk assessment methodologies used in healthcare and industry Discussion of radiation oncology-specific risk assessment strategies and issues Evaluation of risk in the context of medical imaging and image quality E. Samei: Research grants from Siemens and GE.

60 APPLIED LIFE SCIENCES↗

WE-B-BRC-01: Current Methodologies in Risk Assessment

Prospective quality management techniques, long used by engineering and industry, have become a growing aspect of efforts to improve quality management and safety in healthcare. These techniques are of particular interest to medical physics as scope and complexity of clinical practice continue to grow, thus making the prescriptive methods we have used harder to apply and potentially less effective for our interconnected and highly complex healthcare enterprise, especially in imaging and radiation oncology. An essential part of most prospective methods is the need to assess the various risks associated with problems, failures, errors, and design flaws in our systems. We therefore begin with an overview of risk assessment methodologies used in healthcare and industry and discuss their strengths and weaknesses. The rationale for use of process mapping, failure modes and effects analysis (FMEA) and fault tree analysis (FTA) by TG-100 will be described, as well as suggestions for the way forward. This is followed by discussion of radiation oncology specific risk assessment strategies and issues, including the TG-100 effort to evaluate IMRT and other ways to think about risk in the context of radiotherapy. Incident learning systems, local as well as the ASTRO/AAPM ROILS system, can also be useful in the risk assessment process. Finally, risk in the context of medical imaging will be discussed. Radiation (and other) safety considerations, as well as lack of quality and certainty all contribute to the potential risks associated with suboptimal imaging. The goal of this session is to summarize a wide variety of risk analysis methods and issues to give the medical physicist access to tools which can better define risks (and their importance) which we work to mitigate with both prescriptive and prospective risk-based quality management methods. Learning Objectives: Description of risk assessment methodologies used in healthcare and industry Discussion of radiation oncology-specific risk assessment strategies and issues Evaluation of risk in the context of medical imaging and image quality E. Samei: Research grants from Siemens and GE.

60 APPLIED LIFE SCIENCES↗