Search NASA⌕ Search

SEARCH · Search NASA

Results for “filter optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,765 records · Page 98

Prototype Test Results for the Single Photon Detection SLR2000 Satellite Laser Ranging System

NASA's aging Satellite Laser Ranging (SLR) network is scheduled to be replaced over the next few years with a fully automated single photon detection system. A prototype of this new system, called SLR2000, is currently undergoing field trials at the Goddard Space Flight Center in Greenbelt, Maryland to evaluate photon counting techniques and determine system hardware, software, and control algorithm performance levels and limitations. Newly developed diode pumped microchip lasers and quadrant microchannel plate-based photomultiplier tubes have enabled the development of this high repetition rate single photon detection SLR system. The SLR2000 receiver threshold is set at the single photoelectron (pe) level but tracks satellites with an average signal level typically much less than 1 pe. The 2 kHz laser fire rate aids in satellite acquisition and tracking and will enable closed loop tracking by accumulating single photon count statistics in a quadrant detector and using this information to correct for pointing errors. Laser transmitter beamwidths of 10 arcseconds (FWHM) or less are currently being used to maintain an adequate signal level for tracking while the receiver field of view (FOV) has been opened to 40 arcseconds to accommodate point ahead/look behind angular offsets. In the near future, the laser transmitter point ahead will be controlled by a pair of Risley prisms. This will allow the telescope to point behind and enable closure of the receiver FOV to roughly match the transmitter beam divergence. Bandpass filters (BPF) are removed for night tracking operations while 0.2 nm or 1 nm filters are used during daylight operation. Both day and night laser tracking of Low Earth Orbit (LEO) satellites has been achieved with a laser transmitter energy of only 65 microjoules per pulse. Satellite tracking is presently limited to LEO satellites until the brassboard laser transmitter can be upgraded or replaced. Simultaneous tracks have also been observed with NASA s SLR standard, MOBLAS 7, for the purposes of data comparison and identification of biases. Work continues to optimize the receive optics; upgrade or replace the laser transmitter; calibrate the quadrant detector, the point ahead Risley prisms, and event timer verniers; and test normal point generation with SLR2000 data. This paper will report on the satellite tracking results to date, issues yet to be resolved, and future plans for the SLR2000 system.

Zagwodzki, Thomas W.↗

Constraints on the flux of Ultra-High Energy neutrinos from WSRT observations

Context. Ultra-high energy (UHE) neutrinos and cosmic rays initiate particle cascades underneath the Moon's surface. These cascades have a negative charge excess and radiate Cherenkov radio emission in a process known as the Askaryan effect. The optimal frequency window for observation of these pulses with radio telescopes on the Earth is around 150 MHz. Aims. By observing the Moon with the Westerbork Synthesis Radio Telescope array we are able to set a new limit on the UHEneutrino flux. Methods. The PuMa II backend is used to monitor the Moon in 4 frequency bands between 113 and 175 MHz with a sampling frequency of 40 MHz. The narrow band radio interference is digitally filtered out and the dispersive effect of the Earth?s ionosphere is compensated for. A trigger system is implemented to search for short pulses. By inserting simulated pulses in the raw data, the detection efficiency for pulses of various strength is calculated. Results. With 47.6 hours of observation time, we are able to set a limit on the UHE neutrino flux. This new limit is an order of magnitude lower than existing limits. In the near future, the digital radio array LOFAR will be used to achieve an even lower limit.

79 ASTRONOMY AND ASTROPHYSICS↗

A unified funnel restoration SQP algorithm

We consider nonlinearly constrained optimization problems and discuss a generic double-loop framework consisting of basic algorithmic ingredients that unifies a broad range of nonlinear optimization solvers. This framework has been implemented in the open-source solver Uno, a Swiss Army knife-like C++ optimization framework that unifies many nonlinearly constrained nonconvex optimization solvers. We illustrate the framework with a sequential quadratic programming (SQP) algorithm that maintains an acceptable upper bound on the constraint violation, called a funnel, that is monotonically decreased to control the feasibility of the iterates. Infeasible quadratic subproblems are handled by a feasibility restoration strategy. Globalization is controlled by a line search or a trust-region method. We prove global convergence of the trust-region funnel SQP method, building on known results from filter methods. We implement the algorithm in Uno, and we provide extensive test results for the trust-region line-search funnel SQP on small CUTEst instances.

Kiessling, David [Katholieke Univ. Leuven, Heverle↗

Design of a supervisory control system for autonomous operation of advanced reactors

Advanced reactors to be deployed in the coming decades will face deregulated energy markets, and may adopt flexible operation to boost profitability. To aid in the transition from baseload to flexible operation paradigm, autonomous operation is sought. This work focuses on the control aspect of autonomous operation. Specifically, a hierarchical control system is designed to support constraint enforcement during routine operational transients. Within the system, data-driven modeling, physics-based state observation, and classical control algorithms are integrated to provide an adaptable and robust solution. A 320 MW Fluoride-cooled High-temperature Pebble-bed Reactor is the design basis for demonstrating the proposed control system. The hierarchical control system consists of a supervisory layer and low-level layer. The supervisory layer receives requests to change the system's operating conditions (e.g., the current reactor power to meet a load -follow), and accepts or rejects them based on constraints that have been assigned. Constraints are issued to keep the plant within an optimal operating region. The low-level layer interfaces with the actuators of the system to fulfill requested changes, while maintaining tracking and regulation duties. Further, to accept requests at the supervisory layer, the Reference Governor algorithm was adopted. To model the dynamics of the reactor, a system identification algorithm, Dynamic Mode Decomposition, was utilized. To estimate the evolution of process variables that cannot be directly measured (e.g., the propagation of delayed neutron precursors), the Unscented Kalman Filter, incorporating a nonlinear model of nuclear dynamics, was adopted. The composition of these algorithms led to a numerical demonstration of constraint enforcement during a 40% power drop transient (at a rate of 5 %/min). Uncontrolled secondary-side temperatures were successfully constrained. Adaptability of the proposed system was demonstrated by modifying the constraint values, and enforcing them during the transient. Robustness was also demonstrated by enforcing constraints under noisy environments.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Analysis of persistent contaminants and personal care products by dispersive liquid-liquid microextraction using hydrophobic magnetic deep eutectic solvents

Here, in this work, hydrophobic magnetic deep eutectic solvents (HMDESs) were used in the development of a simple and rapid dispersive liquid-liquid microextraction (DLLME) approach coupled to high performance liquid chromatography with UV detection (HPLC-UV) for the determination of ten organic contaminants including five polycyclic aromatic hydrocarbons, four UV filters, and a pesticide from water at trace levels. The HMDESs were prepared by mixing a hydrogen bond acceptor, metal halide salt, and hydrogen bond donor in suitable molar ratios. Two HMDESs, 2 tetraoctylammonium bromide ([N 8888 + ][Br - ]): cobalt chloride (CoCl 2 ): 4 octanoic acid (OA) and 3 trioctylphosphine oxide (TOPO): neodymium chloride (NdCl 3 ): 3 OA, offered the highest analyte extraction efficiency overall and were chosen as suitable solvents for validation of the microextraction method. Under optimized extraction conditions, the method required 30 µL of HMDES as extraction solvent, acetone (87.5 µL) as disperser solvent, a NaCl concentration of 30% (w/v), and an extraction time of 120 s at 20°C. Enrichment factors of the analytes ranged from 44.6 for 3-(4-methylbenzylindene) camphor to 66.0 for 2-ethylhexyl-4-(dimethyl)aminobenzoate. The method provided low limits of detection (LODs) ranging from 0.5 to 4.5 µg L -1 , and acceptable precision, with RSD values lower than 9.6%. Furthermore, the validated method was successfully applied for tap and lake water analysis, resulting in relative recoveries of spiked samples ranging between 94.7 and 119.2%.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Investigation of statistical iterative reconstruction for dedicated breast CT

Purpose: Dedicated breast CT has great potential for improving the detection and diagnosis of breast cancer. Statistical iterative reconstruction (SIR) in dedicated breast CT is a promising alternative to traditional filtered backprojection (FBP). One of the difficulties in using SIR is the presence of free parameters in the algorithm that control the appearance of the resulting image. These parameters require tuning in order to achieve high quality reconstructions. In this study, the authors investigated the penalized maximum likelihood (PML) method with two commonly used types of roughness penalty functions: hyperbolic potential and anisotropic total variation (TV) norm. Reconstructed images were compared with images obtained using standard FBP. Optimal parameters for PML with the hyperbolic prior are reported for the task of detecting microcalcifications embedded in breast tissue.Methods: Computer simulations were used to acquire projections in a half-cone beam geometry. The modeled setup describes a realistic breast CT benchtop system, with an x-ray spectra produced by a point source and an a-Si, CsI:Tl flat-panel detector. A voxelized anthropomorphic breast phantom with 280 μm microcalcification spheres embedded in it was used to model attenuation properties of the uncompressed woman's breast in a pendant position. The reconstruction of 3D images was performed using the separable paraboloidal surrogates algorithm with ordered subsets. Task performance was assessed with the ideal observer detectability index to determine optimal PML parameters.Results: The authors' findings suggest that there is a preferred range of values of the roughness penalty weight and the edge preservation threshold in the penalized objective function with the hyperbolic potential, which resulted in low noise images with high contrast microcalcifications preserved. In terms of numerical observer detectability index, the PML method with optimal parameters yielded substantially improved performance (by a factor of greater than 10) compared to FBP. The hyperbolic prior was also observed to be superior to the TV norm. A few of the best-performing parameter pairs for the PML method also demonstrated superior performance for various radiation doses. In fact, using PML with certain parameter values results in better images, acquired using 2 mGy dose, than FBP-reconstructed images acquired using 6 mGy dose.Conclusions: A range of optimal free parameters for the PML algorithm with hyperbolic and TV norm-based potentials is presented for the microcalcification detection task, in dedicated breast CT. The reported values can be used as starting values of the free parameters, when SIR techniques are used for image reconstruction. Significant improvement in image quality can be achieved by using PML with optimal combination of parameters, as compared to FBP. Importantly, these results suggest improved detection of microcalcifications can be obtained by using PML with lower radiation dose to the patient, than using FBP with higher dose.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Bounded state space

This investigation is divided functionally into three different areas: (1) study of bounded state space, (2) nonlinear smoothing theory, and (3) system identification. (1) Study of bounded state space: necessary and sufficient conditions for an optimal control are obtained for a bounded state space optimal control problem. The difficulty of determining the so-called jump conditions is eliminated; however, the problem of determining the points where the response either enters or leaves the boundary still remains unsolved. (2) Nonlinear smoothing theory: nonlinear fixed-interval, fixed-point and fixed-lag smoothing of a random signal generated by a stochastic differential equation are investigated. Results on the asymptotic stability of a linear constant-parameter fixed-interval smoothing filter are obtained. (3) System identification: a particular stochastic modelling problem is solved. An Ito stochastic integral equation is used to mathematically model a black box having multiple inputs and multiple outputs. A new method for identifying system parameters is presented.

Eyman, E. D.↗

Additional studies for the spectrophotometric measurement of iodine in water

Previous work in iodine spectroscopy is briefly reviewed. Continued studies of the direct spectrophotometric determination of aqueous iodine complexed with potassium iodide show that free iodine is optimally determined at the isosbestic point for these solutions. The effects on iodine determinations of turbidity and chemical substances (in trace amounts) is discussed and illustrated. At the levels tested, iodine measurements are not significantly altered by such substances. A preliminary design for an on-line, automated iodine monitor with eventual capability of operating also as a controller was analyzed and developed in detail with respect single beam colorimeter operating at two wavelengths (using a rotating filter wheel). A flow-through sample cell allows the instrument to operate continuously, except for momentary stop flow when measurements are made. The timed automatic cycling of the system may be interrupted whenever desired, for manual operation. An analog output signal permits controlling an iodine generator.

Source record↗

Communications technology

The technologies for optimized, i.e., state of the art, operation of satellite-based communications systems are surveyed. Features of spaceborne active repeater systems, low-noise signal amplifiers, power amplifiers, and high frequency switches are described. Design features and capabilities of various satellite antenna systems are discussed, including multiple beam, shaped reflector shaped beam, offset reflector multiple beam, and mm-wave and laser antenna systems. Attitude control systems used with the antenna systems are explored, along with multiplexers, filters, and power generation, conditioning and amplification systems. The operational significance and techniques for exploiting channel bandwidth, baseband and modulation technologies are described. Finally, interconnectivity among communications satellites by means of RF and laser links is examined, as are the roles to be played by the Space Station and future large space antenna systems.

Cuccia, C. Louis↗

The Feasibility of Tropospheric and Total Ozone Determination Using a Fabry-perot Interferometer as a Satellite-based Nadir-viewing Atmospheric Sensor

Monitoring of the global distribution of tropospheric ozone (O3) is desirable for enhanced scientific understanding as well as to potentially lessen the ill-health impacts associated with exposure to elevated concentrations in the lower atmosphere. Such a capability can be achieved using a satellite-based device making high spectral resolution measurements with high signal-to-noise ratios; this would enable observation in the pressure-broadened wings of strong O3 lines while minimizing the impact of undesirable signal contributions associated with, for example, the terrestrial surface, interfering species, and clouds. The Fabry-Perot Interferometer (FPI) provides high spectral resolution and high throughput capabilities that are essential for this measurement task. Through proper selection of channel spectral regions, the FPI optimized for tropospheric O3 measurements can simultaneously observe a stratospheric component and thus the total O3 column abundance. Decreasing stratospheric O3 concentrations may lead to an increase in biologically harmful solar ultraviolet radiation reaching the earth's surface, which is detrimental to health. In this research, a conceptual instrument design to achieve the desired measurement has been formulated. This involves a double-etalon fixed-gap series configuration FPI along with an ultra-narrow bandpass filter to achieve single-order operation with an overall spectral resolution of approximately .068 cm(exp -1). A spectral region of about 1 cm(exp -1) wide centered at 1054.73 cm(exp -1) within the strong 9.6 micron ozone infrared band is sampled with 24 spectral channels. Other design characteristics include operation from a nadir-viewing satellite configuration utilizing a 9 inch (diameter) telescope and achieving horizontal spatial resolution with a 50 km nadir footprint. A retrieval technique has been implemented and is demonstrated for a tropical atmosphere possessing enhanced tropospheric ozone amounts. An error analysis assessing the impact on retrieved O3 amounts of the most significant uncertainties associated with this particular measurement has been performed for several different types of atmospheres. Results show the proposed instrumentation to enable a good measurement of absolute ozone amounts and an even better determination of relative changes, with a range of accuracy to within 7.55 to 20.6 percent for integrated tropospheric amounts (and 1.99 to 4.02 percent for total O3 column abundance) and a corresponding range in precision to within 7.73 to 10.4 percent (and 3.30 to 3.95 percent for total O3 column abundance), for the atmospheric conditions considered.

Larar, Allen Maurice↗

RFI at L-band in Synthetic Aperture Radiometers

The spectral window at 1.413 GHz (L-band), set aside for passive use only, is critical for passive remote sensing of the earth from space. It is the largest spectral window available in the long wavelength end of the microwave spectrum where measurements are needed to monitor parameters of the surface such as soil moisture and sea surface salinity. The sensitivity to these parameters is rapidly lost at higher frequencies and is compromised by the ionosphere and antenna size at lower frequencies. Instruments for remote sensing from space in this spectral window are being developed by NASA (Aquarius) and ESA (SMOS) and are expected to be in orbit in a few years (2006). Although the band at 1.413 GHz is protected for passive use, RFI is a common problem. For example, the synthetic aperture radiometer, ESTAR (L-band, Horizontal polarization), has frequently experienced problems with RFI. During the Southern Great Plains Experiments (1997 and 1999), ESTAR experienced RFI significant enough to warrant changes in flight lines. The largest sources of RFI were identified as originating in airports and a likely source is air traffic control radar. In experiments in the vicinity of Richmond, VA, RFI in the form of periodic spikes was recorded, again suggestive of radar. However, in most cases the sources of the RFI are unknown. RFI is a sufficiently common problem that the first step in processing ESTAR data is a screening for RFI (a filter is used to detect large, rapid changes in brightness). Recently, measurements have been made with a new synthetic aperture radiometer, 2D-STAR. Examples of RFI observed simultaneously with ESTAR and the new synthetic aperture radiometer will be presented. 2D-STAR is an airborne instrument designed to develop the technology of aperture synthesis in two dimensions. It employs dual polarized patch antennas arranged in a cross configuration (+). Synthesis in two dimensions offers the potential for optimal thinning, but because of the wide field of view of the individual antennas it is potentially more susceptible to RFI. The 2D-STAR instrument was flown together with ESTAR in a series of test flights on the NASA P-3 aircraft near the Wallops Flight Facility during the summer of 2002. Both instruments experienced RFI over common locations. Examples will be presented and a comparison between instruments presented.

LeVine, David M.↗

SAR Imagery Segmentation by Statistical Region Growing and Hierarchical Merging

This paper presents an approach to accomplish synthetic aperture radar (SAR) image segmentation, which are corrupted by speckle noise. Some ordinary segmentation techniques may require speckle filtering previously. Our approach performs radar image segmentation using the original noisy pixels as input data, eliminating preprocessing steps, an advantage over most of the current methods. The algorithm comprises a statistical region growing procedure combined with hierarchical region merging to extract regions of interest from SAR images. The region growing step over-segments the input image to enable region aggregation by employing a combination of the Kolmogorov-Smirnov (KS) test with a hierarchical stepwise optimization (HSWO) algorithm for the process coordination. We have tested and assessed the proposed technique on artificially speckled image and real SAR data containing different types of targets.

42 ENGINEERING↗

Dose reconstruction for real-time patient-specific dose estimation in CT

Purpose: Many recent computed tomography (CT) dose reduction approaches belong to one of three categories: statistical reconstruction algorithms, efficient x-ray detectors, and optimized CT acquisition schemes with precise control over the x-ray distribution. The latter category could greatly benefit from fast and accurate methods for dose estimation, which would enable real-time patient-specific protocol optimization. Methods: The authors present a new method for volumetrically reconstructing absorbed dose on a per-voxel basis, directly from the actual CT images. The authors’ specific implementation combines a distance-driven pencil-beam approach to model the first-order x-ray interactions with a set of Gaussian convolution kernels to model the higher-order x-ray interactions. The authors performed a number of 3D simulation experiments comparing the proposed method to a Monte Carlo based ground truth. Results: The authors’ results indicate that the proposed approach offers a good trade-off between accuracy and computational efficiency. The images show a good qualitative correspondence to Monte Carlo estimates. Preliminary quantitative results show errors below 10%, except in bone regions, where the authors see a bigger model mismatch. The computational complexity is similar to that of a low-resolution filtered-backprojection algorithm. Conclusions: The authors present a method for analytic dose reconstruction in CT, similar to the techniques used in radiation therapy planning with megavoltage energies. Future work will include refinements of the proposed method to improve the accuracy as well as a more extensive validation study. The proposed method is not intended to replace methods that track individual x-ray photons, but the authors expect that it may prove useful in applications where real-time patient-specific dose estimation is required.

60 APPLIED LIFE SCIENCES↗

Count Rate Optimizations for TES Detectors at a Femtosecond X-ray Laser

Transition-edge sensor microcalorimeters have found success as X-ray detectors at synchrotron light-sources, due to a unique combination of high collecting area and good energy resolution. However, the upcoming generation of free-electron lasers (FELs), such as the Linac Coherent Light Source II, is designed to deliver more than 10 10 photons in a 100 fs pulse at a 100 kHz rate, potentially leading to severe pulse-pileup issues. Here we will demonstrate that, for most relevant science cases, it is possible to mitigate pulse pile-up using simple X-ray filters in a way that takes advantage of the substantial increase in X-ray flux at modern FELs.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Synthesis of graphene-like transparent conductive films on dielectric substrates using a modified filtered vacuum arc system

Here, we present a reliable process to deposit transparent conductive films on silicon oxide, quartz, and sapphire using a solid carbon source. This layer consists of partially ordered graphene flakes with a lateral dimension of about 5 nm. The process does not require any catalytic metal and exploits a high current arc evaporation (Φ-HCA) to homogeneously deposit a layer of carbon on heated substrates. A gas atmosphere consisting of Argon or Argon/Hydrogen blend acting as a buffer influences the morphology of the growing film. scanning tunneling microscopy, transmission electron microscopy, and Raman spectra were used for a thorough characterization of the samples in order to optimize the growth parameters. The best carbon layers have a surface resistance of 5.7 × 10{sup 3} Ω{sub ◻} whereas the optical transparency of the coatings is 88% with an excellent homogeneity over areas of several cm{sup 2}. Such results are compatible with most semiconductor fabrication processes and make this method very promising for various industrial applications.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

High-sensitivity detection of polycyclic aromatic hydrocarbons adsorbed onto soot particles using laser desorption/laser ionization/time-of-flight mass spectrometry: An approach to studying the soot inception process in low-pressure flames

Species adsorbed at the surfaces of soot particles sampled at different locations in a low-pressure methane flame have been analyzed. The analysis method is laser desorption/laser ionization/time-of-flight mass spectrometry (LD/LI/TOF-MS) applied to soot particles deposited on a filter after probe extraction in the flame. In order to fully characterize the experimental apparatus, a strategy of systematic investigations has been adopted, beginning with the study of less complex systems constituted by model soot (standard polycyclic aromatic hydrocarbons, PAHs, adsorbed on black carbon), and then natural soot sampled from a literature reference ethylene flame. This characterization allowed a good understanding of the analytical response of PAHs to the desorption and ionization processes and the definition of the optimal experimental conditions. The soot PAH content was then investigated on a low-pressure methane/oxygen/nitrogen premixed flat flame ({phi} = 2.32) as a function of the sampling height above the burner (HAB). The obtained mass spectra are reproducible, fragment-free, well resolved in the analyzed m/z range and they are characterized by an excellent signal-to-noise ratio. They all feature regular peak sequences, where each signal peak has been assigned to the most stable high-temperature-formed PAHs. The structure of the mass spectra depends on the sampling HAB into the flame, i.e., on the reaction time. An original contribution to the data interpretation comes from the development of a new sampling method that makes it possible to infer hypotheses about the PAH partition between the gas phase and the soot particles. This method highlights the presence of high-mass PAHs in the soot nucleation zone, and it suggests the importance of heterogeneous reactions occurring between flame PAHs and soot particles. (author)

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Optimization and characterization of a silicon photomultiplier-based ZnS(Ag) proton recoil fast neutron detector for nuclear fuel performance monitoring at TREAT

The restart of the Transient Reactor Test Facility (TREAT) at Idaho National Laboratory and consequent refurbishment of the Fuel Motion Monitoring System (FMMS), or Hodoscope, offers the opportunity to upgrade the detector system used for neutron imaging. Silicon photomultipliers (SiPMs) are a viable option for updating the Hodoscope to yield improved fuel monitoring capability. The Hodoscope uses ZnS(Ag) proton recoil scintillators (PRS) that provide good gamma-ray suppression and discrimination. Previous work showed that the Hamamatsu S13360-6075CS SiPM offers the best neutron detection and gamma-ray discrimination capability with the ZnS PRS. This work optimizes a SiPM-based detector and develops a PRS prototype for testing. Specifically, possible overvoltages for use are determined by confirming steady operation over extended measurement times. In addition, various SiPM-circuit implementations are tested to optimize the detector according to desired properties, and ultimately a PRS prototype is developed with modifiable components for versatile testing. Measurements of the neutron detection efficiency and gamma-ray rejection efficiency of SiPM-based PRS detectors and a reference PMT-based detector are also carried out. Neutron detection efficiency ranges between 1-2%, and detected gamma-ray rejection efficiency is on the order of 10 -7 . In conclusion, use of a low-pass filter only or a low-pass filter and 50-ω shunt resistor is recommended for the SiPM-based detector, and both configurations demonstrate improved performance over the PMT-based detector.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Study of Triple Ar Gas Puff Z-Pinches on 0.9-MA, 200-ns COBRA

Ar gas puff z-pinch experiments were conducted on the 0.9 MA, 200 ns COBRA generator at Cornell University. In the experiments, a triple-nozzle gas valve was used to produce the zpinch load with concentric outer and inner gas puffs and a central gas jet. We used Planer Laser Induced Fluorescence (PLIF) to measure the initial gas profile of the load, two 4-frame 4-ns gated XUV cameras to image the imploding plasma, and filtered Photo- Conducting Diamond Detectors (PCDs) to measure the x-ray output. We have observed shock heating and/or photoionization of the dense center jet by the imploding plasma. With an outer to inner plenum pressure ratio of 1:3, de-acceleration of the imploding plasma occurred when the outer plasma shell imploded on the inner shell resulting in a stable implosion. By varying the plenum pressure for the center jet, the x-ray emission was optimized. In conclusion, an Ar K-shell x-ray (3-4 keV) yield of 77±17 J was produced at a current level of 0.87±0.2 MA and an implosion time of 200-ns.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗