Search NASA⌕ Search

SEARCH · Search NASA

Results for “grating”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,765 records · Page 98

Self-pulsing and bichromatic emission in homogeneously broadened bidirectional ring lasers

The effects of saturation-induced Bragg gratings on the mode structure and dynamics of bidirectional homogeneously broadened ring lasers are studied. The grating is viewed as a distributed feedback medium in a ring cavity and modes appropriate to such a structure are used. A Fourier decomposed rate equation model is developed to study the behavior of these modes above threshold. The difference in the properties of these solutions from the modes of an unfilled ring cavity lead to the possibility of bichromatic emission and both regular undamped and irregular damped self-pulsing.

Rabinovich, W. S.↗

Imaging spectrometer for high resolution measurements of stratospheric trace constituents in the ultraviolet

A high-resolution spectrometer has been developed for studies of minor constituents in the middle atmosphere at ultraviolet wavelengths. In particular, the instrument is intended for observations of upper stratospheric UV bands. The spectrometer has a slit width of 0.08 A obtained by means of an echelle grating and a cross-disperser grating. The image plane detector is an intensified CCD consisting of a high gain proximity focused image intensifier that is fiber optically coupled to a two-dimensional CCD array. An instantaneous bandwidth of 9.2 A is resolved across 488 pixels at 0.018 A/pixel, permitting simultaneous acquisition of multiple lines of selected OH bands and the neighboring background. The spectrometer and the approach have been successfully demonstrated as a technique for measuring the concentration of OH on two high-altitude balloon flights. This paper reports the instrument design and its achieved performance.

Torr, Marsha R.↗

Ground based infrared astronomy

Infrared spectroscopic instrumentation has been developed for ground-based measurements of astrophysical objects in the intermediate infrared. A conventional Michelson interferometer is limited for astronomical applications in the intermediate infrared by quantum noise fluctuations in the radiation form the source and/or background incident on the detector, and the multiplex advantage is no longer available. One feasible approach to recovering the multiplex advantage is post-dispersion. The infrared signal after passing through telescope and interferometer, is dispersed by a low resolution grating spectrometer onto an array of detectors. The feasibility of the post-dispersion system has been demonstrated with observations of astrophysical objects in the 5 and 10 micrometer atmospheric windows from ground-based telescopes. During FY87/88 the post-disperser was used at the Kitt Peak 4-meter telescope and McMath telescope with facility Fourier transform spectrometers. Jupiter, Saturn, Mars, and Venus were observed. On Jupiter, the resolution at 12 micrometer was 0.01/cm, considerably higher than had been acheived previously. The spectrum contains Jovian ethane and acetylene emission. Construction was begun on the large cryogenic grating spectrometer.

Jennings, D. E.↗

Precision in the perception of direction of a moving pattern

The precision of the model of pattern motion analysis put forth by Adelson and Movshon (1982) who proposed that humans determine the direction of a moving plaid (the sum of two sinusoidal gratings of different orientations) in two steps is qualitatively examined. The volocities of the grating components are first estimated, then combined using the intersection of constraints to determine the velocity of the plaid as a whole. Under the additional assumption that the noise sources for the component velocities are independent, an approximate expression can be derived for the precision in plaid direction as a function of the precision in the speed and direction of the components. Monte Carlo simulations verify that the expression is valid to within 5 percent over the natural range of the parameters. The expression is then used to predict human performance based on available estimates of human precision in the judgment of single component speed. Human performance is predicted to deteriorate by a factor of 3 as half the angle between the wavefronts (theta) decreases from 60 to 30 deg, but actual performance does not. The mean direction discrimination for three human observers was 4.3 plus or minus 0.9 deg (SD) for theta = 60 deg and 5.9 plus or minus 1.2 for theta = 30 deg. This discrepancy can be resolved in two ways. If the noises in the internal representations of the component speeds are smaller than the available estimates or if these noises are not independent, then the psychophysical results are consistent with the Adelson-Movshon hypothesis.

Stone, Leland S.↗

AlGaAs phased array laser for optical communications

Phased locked arrays of multiple AlGaAs diode laser emitters were investigated both in edge emitting and surface emitting configurations. CSP edge emitter structures, coupled by either evanescent waves or Y-guides, could not achieve the required powers (greater than or similar to 500 mW) while maintaining a diffraction limited, single lobed output beam. Indeed, although the diffraction limit was achieved in this type of device, it was at low powers and in the double lobed radiation pattern characteristic of out-of-phase coupling. Grating surface emitting (GSE) arrays were, therefore, investigated with more promising results. The incorporation of second order gratings in distribute Bragg reflector (DBR) structures allows surface emission, and can be configured to allow injection locking and lateral coupling to populate 2-D arrays that should be able to reach power levels commensurate with the needs of high performance, free space optical communications levels. Also, a new amplitude modulation scheme was developed for GSE array operation.

Carlson, N. W.↗

Optically-Tuned Far-Infrared Device

Spacing of visible interference pattern determines frequency of infrared radiation. Variable photoconductivity grating formed by interference of two visible laser beams intersecting on surface of proposed AlGaAs device substituted for fixed metal grating. Proposed device provides higher output-power density and greater tunability.

Katz, Joseph↗

Deferred electronic heterodyne moire deflectometry: A method for transient density fields measurement

Effects of spherical aberrations of the mirror used in the moire system on the angular resolution of the system are investigated. It is shown that the spherical aberrations may reduce significantly the performance of the conventional moire deflectometer. However, due to the heterodyne procedure, this is not the case with the heterodyne moire system. A moire system with a constant speed moving grating is demonstrated. It is shown that the system readout is linear and the system does not need calibration. In addition, the repeatability of the measurements is improved in this system as compared to the sinusoidally moving grating setup. The problem of the photographic plates alignment is solved by using a mechanical system in which the plate is held firmly throughout the experiment and accurately replaced after removing for photographic processing. The effect of a circular detector's aperture size on readout was tested. It is shown that the spatial phase variations, observed when scanning along a straight moire fringe, may considerably be reduced. At present we may say that both the on-line and the deferred heterodyne moire techniques may reliably be used. The errors of phase readings are 1 deg and 5 deg for the on-line and deferred methods. The total error due to subtraction of two readings at each position is, therefore, 1.4 deg and 7 deg, respectively. Further research for improving the deferred system is suggested.

Stricker, Josef↗

Exosat observations of Cygnus X-2 continuum and line spectrum

An analysis of five Exosat observations of Cyg X-2, taken around a full binary orbit is presented. The data were obtained using all instrumentation (1000 lines/mm Transmission Grating Spectrometer, Channel Multiplier Array + filters, Medium-Energy experiment, and Gas Scintillation Proportional Counter) simultaneously, and span the full energy range 0.5-20 keV. No clear evidence was found for a correlation of any of the source characteristics with orbital phase. During two of the observations, significant iron K emission at 6.7 keV was detected, the relative strength of which seems to correlate with total X-ray intensity during two sharp intensity dips. The previous detection of discrete emission features in the 12-19 A band with the Einstein grating is confirmed.

Chiappetti, L.↗

Multiaperture Spectrometer

Proposed multiaperture spectrometer containing single grating provides high spectral resolution over broad spectrum. Produces parallel line images, each of which highly spectrally resolved display of intensity vs. wavelength in wavelength band of one of orders of spectrum produced by grating. Advantages; convenient two-dimensional spectral image, fewer components, and greater efficiency.

Schindler, Rudolf A.↗

Structures and characteristics of commercially available 1.5 micron InGaAsP distributed feedback laser diodes

The characteristics of commercially available 1.5-micron distributed feedback (DFB) laser diodes obtained from seven manufacturers were investigated, and the results are correlated with the lasers' structural parameters. It was found that buried heterostructures with first-order gratings showed consistently good results (as opposed to buried heterostructures with second-order gratings). A ridge waveguide laser was near the bottom of most performance charts.

Cook, A. L.↗

Optical design of Lyman/FUSE

The optical system for the proposed Lyman/Far UV Spectroscopic Explorer (FUSE) orbiting observatory is described and illustrated with drawings and graphs of predicted performance. The system comprises (1) an FUV channel based on a 1.84-m-diameter Rowland circle spectrograph with five high-density modified ellipsiodal near-normal-incidence gratings and an array of four MAMA detectors; (2) an EUV channel with ellipsoidal mirror, planar varied-line-space grating, microchannel-plate array, and wedge-and-strip anode detector; (3) a 70-cm Wolter II glancing-incidence telescope; and (4) a CCD-detector fine-error sensor to provide accurate pointing (within 200 marcsec rms). The resolving powers of the spectrographs are 30,000 in the FUV and 300-600 (wavelength-dependent) in the EUV.

Content, D. A.↗

X-ray optics. II - A technique for high resolution spectroscopy

A novel combination of optical elements and properties is combined to achieve high-spectral resolution using grazing incidence optics of modest quality. Analysis and ray tracing of examples show that using radial groove gratings at high blaze angles in the manner of an echelle spectrograph can provide high spectral resolution. This arrangement is compared to the conventional in-plane designs to show that the off-plane is superior in nearly every respect. Cross dispersion can be provided by the energy resolution of a CCD detector. Additional resolution can be squeezed from the system by strategic placement of gratings to take advantage of the azimuthal response of a Wolter X-ray optic.

Cash, Webster C., Jr.↗

A high resolution echelle spectrometer for soft X-ray and EUV astronomy

A new design is presented for high resolution spectroscopy from 80 to 400 A. This design employs grazing incidence optics and variable line-spaced gratings to achieve high resolution. Unlike some previously proposed EUV echelles, this design employs straight groove planar gratings, which are a well-proven, easily manufactured design. The instrument delivers a peak resolution of 7500 and a peak effective area of 3 sq cm.

Green, James↗

Dispersive spectroscopy on AXAF

The designs of two transmission grating spectrometers and a Bragg crystal spectrometer that are being developed for the Advanced X-ray Astrophysics Facility (AXAF) are described. The gratings, which are composed of arrays of small facets mounted on plates which can be inserted immediately behind the AXAF telescope, divide the AXAF energy band (80 eV-10 keV) into three regions and attain very high resolving powers for point sources. The Bragg Crystal Spectrometer (BCS) is a focal plane instrument, in which X-rays that satisfy the Bragg law are reflected from a curved crystal which refocuses the beam onto an imaging detector. The BCS achieves the highest spectral resolutions of the AXAF spectrometers: for E values between 500 and 1600 eV, the FWHM of a narrow line is less than 1 eV.

Markert, T. H.↗

A Cassegrain echelle spectrograph

The 'LPL echelle' is a CCD spectrograph with a resolving power of 160,000 and enough sensitivity to detect the brighter airglow emissions in a few minutes. It uses an R3.2 grating in a novel out-of-plane mounting that permits any wavelength to be placed on the blaze. A single order is selected by a medium-band interference filter. Lower dispersions and broader wavelength coverage are obtained by replacing the echelle by a 600 line/mm grating or a Littrow prism.

Hunten, D. M.↗

Reconfigurable optical interconnection network for multimode optical fiber sensor arrays

A single-source, single-detector architecture has been developed to implement a reconfigurable optical interconnection network multimode optical fiber sensor arrays. The network was realized by integrating LiNbO3 electrooptic (EO) gratings working at the Raman Na regime and a massive fan-out waveguide hologram (WH) working at the Bragg regime onto a multimode glass waveguide. The glass waveguide utilized the whole substrate as a guiding medium. A 1-to-59 massive waveguide fan-out was demonstrated using a WH operating at 514 nm. Measured diffraction efficiency of 59 percent was experimentally confirmed. Reconfigurability of the interconnection was carried out by generating an EO grating through an externally applied electric field. Unlike conventional single-mode integrated optical devices, the guided mode demonstrated has an azimuthal symmetry in mode profile which is the same as that of a fiber mode.

Chen, R. T.↗

The MIT high resolution X-ray spectroscopy instruments on AXAF

The general design and performance characteristics of MIT's two dispersive spectrometers, the Bragg Crystal Spectrometer (BCS) and the High Energy Transmission Grating Spectrometer (HETG), now being developed for the Advanced X-ray Astrophysics Facility (AXAF), are described. Particular attention is given to the development of the critical technologies incorporated into these instruments, including BCS diffractors, imaging gas flow proportional counters, and grating elements for the HETG. The principal stages and the current status of the developments are reviewed.

Canizares, C. R.↗

The potential for plasma diagnostics from stellar extreme-ultraviolet observations

A description of the lines from the most abundant ions in the EUV spectrum in the range 50-500 A that have special diagnostic significance is presented. These lines are from plasmas in the temperature range from 10 exp 5 to 10 exp 7 K. Their utility for determining temperature, density, and abundances is demonstrated. An objective grating spectrometer, based on the Skylab slitless spectrograph, for making celestial observations in the EUV spectral region with high spectral resolution is also described. Such an instrument, if equipped with a multilayer grating, can achieve efficiencies over limited EUV wavelength ranges that rival much larger telescope-spectrometer instruments for the observation of stars and other celestial objects.

Feldman, U.↗