Search NASA⌕ Search

SEARCH · Search NASA

Results for “integer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,765 records · Page 98

Understanding the physics of a possible non-Abelian fractional quantum hall effect state.

We wish to present in this report experimental results from a one-year Senior Council Tier-1 LDRD project that focused on understanding the physics of a possible non-Abelian fractional quantum Hall effect state. We first give a general introduction to the quantum Hall effect, and then present the experimental results on the edge-state transport in a special fractional quantum Hall effect state at Landau level filling {nu} = 5/2 - a possible non-Abelian quantum Hall state. This state has been at the center of current basic research due to its potential applications in fault-resistant topological quantum computation. We will also describe the semiconductor 'Hall-bar' devices we used in this project. Electron physics in low dimensional systems has been one of the most exciting fields in condensed matter physics for many years. This is especially true of quantum Hall effect (QHE) physics, which has seen its intellectual wealth applied in and has influenced many seemingly unrelated fields, such as the black hole physics, where a fractional QHE-like phase has been identified. Two Nobel prizes have been awarded for discoveries of quantum Hall effects: in 1985 to von Klitzing for the discovery of integer QHE, and in 1998 to Tsui, Stormer, and Laughlin for the discovery of fractional QHE. Today, QH physics remains one of the most vibrant research fields, and many unexpected novel quantum states continue to be discovered and to surprise us, such as utilizing an exotic, non-Abelian FQHE state at {nu} = 5/2 for fault resistant topological computation. Below we give a briefly introduction of the quantum Hall physics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Booster and AGS transverse emittance during the 2006 and 2009 polarized proton runs

This note is an overview of issues relating to transverse polarized proton emittance in the Booster and AGS. It also compares the transverse emittance during the FY09 polarized proton run with it during the FY06 run as several changes were made for the FY09 run in an attempt to reduce the transverse emittance coming out of the AGS. The FY06 run is used for comparison because it was relatively long, and it's believed that the performance of the injectors for polarized protons, up until FY09, was best during that run. Over the shutdown just before the FY09 run work was done in LEBT and MEBT to reduce the emittance coming out of the Linac. Measurements of the beam coming out of Linac1 indicate that the horizontal normalized emittance was reduced from 11.0 {pi} to 4.5 {pi}mm mrad, and that the vertical normalized emittance was reduced from 12.1 {pi} to 5.5 {pi} mm mrad going from FY06 to FY09. There were 2 new types of stripping foil installed in the Booster, called descriptively the 'strip' (No.6) and 'stamp' (No.2) foil, both nominally 100 {micro}g/cm{sup 2}. Both foils are composed of a diamond like material, and designed to reduce the number of times the beam goes through the foil. Other than those, there are two standard 100 {micro}g/cm carbon foils (No.3 and 5), and one 200 {micro}g/cm{sup 2} carbon foil (No.4). Of the two 100 {micro}g/cm{sup 2} foils, one has shown some deterioration (No.3) in stripping efficiency. During the FY06 run a standard 100 {micro}g/cm{sup 2} foil was generally used, and during the FY09 run the strip foil was generally used, though the stamp foil was also used for the last 3-4 weeks of the run. Both the FY06 and FY09 runs were about 5 months long, starting in late January, FY06 ending in late June, and FY09 ending in early July. A new injection setup was used for about the last 3 months of FY09, from the beginning of April to the end of the run. This setup uses 1/2 integer stopband correctors with the tunes near, but slightly greater than, 4.5 to distort the {beta} functions at the foil in order to reduce the emittance blowup caused by scattering on the foil. New BtA quad settings, largely based on a MAD model of the BtA line and AGS were used for virtually the entire FY09 run (Feb 5 to the end) in an attempt to improve the matching into the AGS. Since, it has been thought for some time that there is emittance blowup in the vertical due to an injection mismatch. The nominal Linac pulse width was decreased from 400 {micro}s to 300 {micro}s in the latter part of february 09, so the vast majority of the FY09 run used a 300 {micro}s pulse width. The standard pulse width for FY06 was 400 {micro}s. This has some implications for comparing the data from FY06 with that from FY09, but they don't seem insurmountable.

43 PARTICLE ACCELERATORS↗

Storage Viability and Optimization Web Service

Non-residential sectors offer many promising applications for electrical storage (batteries) and photovoltaics (PVs). However, choosing and operating storage under complex tariff structures poses a daunting technical and economic problem that may discourage potential customers and result in lost carbon and economic savings. Equipment vendors are unlikely to provide adequate environmental analysis or unbiased economic results to potential clients, and are even less likely to completely describe the robustness of choices in the face of changing fuel prices and tariffs. Given these considerations, researchers at Lawrence Berkeley National Laboratory (LBNL) have designed the Storage Viability and Optimization Web Service (SVOW): a tool that helps building owners, operators and managers to decide if storage technologies and PVs merit deeper analysis. SVOW is an open access, web-based energy storage and PV analysis calculator, accessible by secure remote login. Upon first login, the user sees an overview of the parameters: load profile, tariff, technologies, and solar radiation location. Each parameter has a pull-down list of possible predefined inputs and users may upload their own as necessary. Since the non-residential sectors encompass a broad range of facilities with fundamentally different characteristics, the tool starts by asking the users to select a load profile from a limited cohort group of example facilities. The example facilities are categorized according to their North American Industry Classification System (NAICS) code. After the load profile selection, users select a predefined tariff or use the widget to create their own. The technologies and solar radiation menus operate in a similar fashion. After these four parameters have been inputted, the users have to select an optimization setting as well as an optimization objective. The analytic engine of SVOW is LBNL?s Distributed Energy Resources Customer Adoption Model (DER-CAM), which is a mixed-integer linear program (MILP) written and executed in the General Algebraic Modeling System (GAMS) optimization software. LBNL has released version 1.2.0.11 of SVOW. Information can be found at http://der.lbl.gov/microgrids-lbnl/current-project-storage-viability-website.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

The PHEV Charging Infrastructure Planning (PCIP) Problem

Increasing debates over a gasoline independent future and the reduction of greenhouse gas (GHG) emissions has led to a surge in plug-in hybrid electric vehicles (PHEVs) being developed around the world. The majority of PHEV related research has been directed at improving engine and battery operations, studying future PHEV impacts on the grid, and projecting future PHEV charging infrastructure requirements. Due to the limited all-electric range of PHEVs, a daytime PHEV charging infrastructure will be required for most PHEV daily usage. In this paper, for the first time, we present a mixed integer mathematical programming model to solve the PHEV charging infrastructure planning (PCIP) problem for organizations with thousands of people working within a defined geographic location and parking lots well suited to charging station installations. Our case study, based on the Oak Ridge National Laboratory (ORNL) campus, produced encouraging results, indicates the viability of the modeling approach and substantiates the importance of considering both employee convenience and appropriate grid connections in the PCIP problem.

02 PETROLEUM↗

Substation-Level Grid Topology Optimization Using Bus Splitting

Operations of substation circuit breakers are important for maintenance needs and topology reconfiguration in power systems. Bus splitting is one type of topology change where the two bus bars at a substation can become electrically disconnected under certain actions of circuit breakers. Because these events involve detailed substation modeling, they are typically not considered in routine power system operation and control. In this paper, an improved substation-level topology optimization framework is developed by expanding traditional line switching decisions by breaker-level bus splitting, which can further reduce grid congestion and generation costs. A tight McCormick relaxation is proposed to reformulate the bilinear terms in the resultant optimization problem to linear inequality constraints. Thus, a tractable mixed-integer linear program reformulation is attained that allows for efficient solutions in real-time operations. Numerical studies on the IEEE 14-bus and 118-bus systems demonstrate the computational performance and economic benefits of the proposed topology optimization approach.

bus split↗

Analyzing Impact of Intermodal Facilities on Design and Management of Biofuel Supply Chain

The impact of an intermodal facility on location and transportation decisions for biofuel production plants is analyzed. Location decisions affect the management of the inbound and outbound logistics of a plant. This supply chain design and management problem is modeled as a mixed integer program. Input data for this model are location of intermodal facilities and available transportation modes, cost and cargo capacity for each transportation mode, geographical distribution of biomass feedstock and production yields, and biomass processing and inventory costs. Outputs from this model are the number, location, and capacity of biofuel production plants. For each plant, the transportation mode used, timing of shipments, shipment size, inventory size, and production schedule that minimize the delivery cost of biofuel are determined. The model proposed in this research can be used as a decision-making tool for investors in the biofuels industry since it estimates the real cost of the business. The state of Mississippi is considered as the testing grounds for the model.

09 BIOMASS FUELS↗

Optimizing ensemble NV − spin properties of fluorescent diamond microparticles by systematic low pressure high temperature annealing

Low pressure high temperature annealing is a means for driving nitrogen and defect diffusion in diamond to reduce internal lattice damage without the need for technically complicated high-pressure cells. Herein, we perform a systematic time (5, 15, and 30 min) and temperature (1200 °C–1800 °C) study of effects of low-pressure high temperature annealing on photoluminescence, spin concentrations, and spin relaxation properties of NV centers in ca. 3 μm synthetic type 1b diamond particles. Annealing in the temperature range of ca. 1400 °C–1700 °C for even 5 min leads to a higher optically detected magnetic resonance contrast as compared to standard annealing at 900 °C for 2 h. Particles annealed at 1700 °C for 5 min exhibit a contrast close to about 13% as compared to about 9% for those annealed at 900 °C for 2 h. A reduction in the zero-field splitting strain parameter from E ≈ 4.5 MHz to ≈ 2.5 MHz and spectral linewidth from Δν ≈ 7 MHz to ≈ 4 MHz are observed even after 5 min annealing at 1700 °C. Improvements in these spectral parameters resulted in a roughly 2-fold reduction in the noise level of temperature monitoring experiment utilizing an ensemble of NV centers in the particles. Annealing in the temperature range of 1600 °C for 15 or 30 min or 1700 °C for 5 min resulted in NV T 1 relaxation times approaching ca. 5 ms typically observed for bulk diamond. Quantitative electron paramagnetic resonance (EPR) allowed for estimations of thermal activation energies of paramagnetic center annihilation. Monitoring the primary defect concentration (P1 and other defects with half integer spins) and utilizing second order kinetic modeling, an activation energy of 3.63 ± 0.28 eV was estimated. Alternatively, using the NV half field EPR signal and first order kinetic modeling, a similar activation energy 3.89 ± 0.29 eV was estimated.

NV centers↗

Theoretical Analysis of Fractional Viscoelastic Flow in Circular Pipes: Parametric Study

Pipe flow is one of the most commonly used models to describe fluid dynamics. The concept of fractional derivative has been recently found very useful and much more accurate in predicting dynamics of viscoelastic fluids compared with classic models. In this paper, we capitalize on our previous study and consider space-time dynamics of flow velocity and stress for fractional Maxwell, Zener, and Burgers models. We demonstrate that the behavior of these quantities becomes much more complex (compared to integer-order classical models) when adjusting fractional order and elastic parameters. We investigate mutual influence of fractional orders and consider their limiting value combinations. Finally, we show that the models developed can be reduced to classical ones when appropriate fractional orders are set.

Gritsenko, Dmitry (ORCID:0000000248181512)↗

Minimal Energy Routing of a Leader and a Wingmate with Periodic Connectivity

We consider a route planning problem in which two unmanned vehicles are required to complete a set of tasks present at distinct locations, referred to as targets, with minimum energy consumption. The mission environment is hazardous, and to ensure a safe operation, the UVs are required to communicate with each other at every target they visit. The problem objective is to determine the allocation of the tasks to the UVs and plan tours for the UVs to visit the targets such that the weighted sum of the distances traveled by the UVs and the distances traveled by the communicating signals between them is minimized. We formulate this problem as an Integer program and show that naively solving the problem using commercially available off-the-shelf solvers is insufficient in determining scalable solutions efficiently. To address this computational challenge, we develop an approximation and a heuristic algorithm, and employ them to compute high-quality solutions to a special case of the problem where equal weights are assigned to the distances traveled by the vehicles and the communicating signals. For this special case, we show that the approximation algorithm has a fixed approximation ratio of 3.75. We also develop lower bounds to the optimal cost of the problem to evaluate the performance of these algorithms on large-scale instances. We demonstrate the performance of these algorithms on 500 randomly generated instances with the number of targets ranging from 6 to 100, and show that the algorithms provide high-quality solutions to the problem swiftly; the average computation time of the algorithmic solutions is within a fraction of a second for instances with at most 100 targets. Finally, we show that the approximation ratio has a variable ratio for the weighted case of the problem. Specifically, if ρ denotes the ratio of the weights assigned to the distances representing the communication and travel costs, the algorithm has an a posteriori ratio of $3 + \frac{3ρ}{4}$ when ρ ≥ 1, and $\frac{3}{ρ}$ + $\frac{3}{4}$ when ρ ≤ 1.

42 ENGINEERING↗

Community Microgrid Scheduling Considering Network Operational Constraints and Building Thermal Dynamics

Here, this paper proposes a Mixed Integer Conic Programming (MICP) model for community microgrids considering the network operational constraints and building thermal dynamics. The proposed optimization model optimizes not only the operating cost, including fuel cost, purchasing cost, battery degradation cost, voluntary load shedding cost and the cost associated with customer discomfort due to room temperature deviation from the set point, but also several performance indices, including voltage deviation, network power loss and power factor at the Point of Common Coupling (PCC). In particular, the detailed thermal dynamic model of buildings is integrated into the distribution optimal power flow (D-OPF) model for the optimal operation of community microgrids. The heating, ventilation and air-conditioning (HVAC) systems can be scheduled intelligently to reduce the electricity cost while maintaining the indoor temperature in the comfort range set by customers. Numerical simulation results show the effectiveness of the proposed model and significant saving in electricity cost could be achieved with network operational constraints satisfied.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Strategic Offering for Wind Power Producers Considering Energy and Flexible Ramping Products

The increasing deployments of renewable generation methods, such as wind, affects the flexibility of electric power system operating due to their inherent variability and uncertainty. To mitigate this, power systems need flexible resources. This paper investigates the potential for wind power to provide flexible ramping products in the real-time market, an additional value stream to the energy it provides. The proposed model for wind power’s strategic offering is formulated as a bi-level optimization problem with wind profit maximization at the upper level and the independent system operator’s economic dispatch—considering both the energy balance and the flexible ramping requirement to counter uncertainty—at the lower level. This bi-level model is converted to a mathematical program with equilibrium constraints (MPEC) by recasting the lower level problem with its Karush–Kuhn–Tucker optimality conditions. Then, through strong duality theory and the big-M method, the MPEC model is converted to a mixed-integer linear programming model. The opportunity cost and the price for wind power-providing ramping products are analyzed. Numerical examples based on a 5-bus network are presented to verify the proposed model and concept.

17 WIND ENERGY↗

Co-Optimized Analysis and Design of Electric and Natural Gas Infrastructures

This paper proposes and implements a long-term deterministic capacity expansion model for the co-optimization of electric and natural gas infrastructures. It determines the required investments in generation units, transmission lines and pipelines for meeting future demands, while representing electricity and natural gas flows using DC Power Flow and Weymouth equations, respectively. A Mixed Integer Nonlinear Programming (MINLP) problem is developed, from which a linearized version is derived. A 26 node integrated gas-electric system for the Eastern Region of the United States is used to demonstrate the model’s capabilities. Results show that the model provides an accurate operational representation of the integrated system, and, therefore, enhances the expansion planning process.

47 OTHER INSTRUMENTATION↗

Per-Phase and 3-Phase Optimal Coordination of Directional Overcurrent Relays Using Genetic Algorithm

Penetration of the power grid by renewable energy sources, distributed storage, and distributed generators is becoming increasingly common. Increased utilization of these distributed energy resources (DERs) has given rise to additional protection coordination concerns, particularly where they are utilized in an unbalanced manner or where loading among phases is unbalanced. Digital relays such as the SEL-751 (produced by Schweitzer Engineering Laboratories, Pullman, WA, USA) series have the capability of being set on a per-phase basis. This capability is underutilized in common practice. Additionally, in optimization algorithms for determining relay settings, the time-overcurrent characteristics (TOCs) of relays are generally not treated as variables and are assigned before running the optimization algorithm. In this paper, TOC options themselves are treated as discrete variables to be considered in the optimization algorithm. A mixed integer nonlinear programming problem (MINLP) is set up where the goal is to minimize relay operating times. A genetic algorithm (GA) approach is implemented in MATLAB where two cases are considered. In the first case, the TOC and Time dial setting (TDS) of each relay is set on a three-phase basis. In the second case, per-phase settings are considered. Relay TDSs and TOCs are both considered as simultaneous discrete control variables. Despite the stochastic nature of using per-phase settings for unbalanced systems is found to generally allow for shorter operating times. However, for relatively balanced systems, it is best to use three-phase settings if computation time is of importance.

Matthews, Ronald C.↗

Improved Air-Conditioning Demand Response of Connected Communities over Individually Optimized Buildings

Connected communities potentially offer much greater demand response capabilities over singular building energy management systems (BEMS) through an increase of connectivity. The potential increase in benefits from this next step in connectivity is still under investigation, especially when applied to existing buildings. This work utilizes EnergyPlus simulation results on eight different commercial prototype buildings to estimate the potential savings on peak demand and energy costs using a mixed-integer linear programming model. This model is used in two cases: a fully connected community and eight separate buildings with BEMS. The connected community is optimized using all zones as variables, while the individual buildings are optimized separately and then aggregated. These optimization problems are run for a range of individual zone flexibility values. The results indicate that a connected community offered 60.0% and 24.8% more peak demand savings for low and high flexibility scenarios, relative to individually optimized buildings. Energy cost optimization results show only marginally better savings of 2.9% and 6.1% for low and high flexibility, respectively.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Dispatch Optimization, System Design and Cost Benefit Analysis of a Nuclear Reactor with Molten Salt Thermal Storage

Variable renewable energy availability has increased the volatility in energy prices in most markets. Nuclear power plants, with a large ratio of capital to variable costs, have historically operated as base load energy suppliers but the need for more flexible operation is increasing. We simulate the techno-economic performance of a 950 MWt nuclear power plant, based on the Westinghouse lead-cooled fast reactor, coupled with molten salt thermal storage as a method for flexible energy dispatch. We use the System Advisor Model to model the nuclear reactor thermal power input and power cycle operating modes. We combine this robust engineering model with a mixed-integer linear program model for optimized dispatch scheduling. We then simulate the coupled nuclear and thermal storage system under different market scenarios with varying price volatility. We find that the coupled plant outperforms the base plant under markets where energy price peaks fluctuate by a factor of two or more about the mean price. We show that a calculated power purchase agreement price for the plant improves by up to 10% when operating under California energy market conditions. Sensitivity analysis on the thermal storage cost shows that the optimal design remains unchanged even when doubling costs.

25 ENERGY STORAGE↗

Series FACTS Devices for Increasing Resiliency in Severe Weather Conditions

Severe weather conditions are low-probability, high-impact events that affect grid operations. The majority of power outages are caused by severe weather conditions. Grid resiliency to weather events can be enhanced by decreasing the reliance on its affected sections. One way to do this is to reduce the power flow through lines vulnerable to severe weather. If a line is disconnected, its initial power flow is distributed through the neighbor lines, which may cause congestion in the grid. FACTS devices can be used to control the power flow of lines that have a higher chance of power outages. Most previous works do not consider weather events in power flow control. In this work, a linearized optimal power flow (OPF)–based algorithm is developed to minimize the real power flow of vulnerable lines considering the thermal limits of lines to prevent infeasible solutions; the simulation is fast, making it suitable for large-scale systems. The proposed optimization problem is presented as a mixed-integer linear program (MILP), making it capable of using short-term load forecasting due to its high solution speed. The proposed optimization problem considers multiple lines with different outage probabilities and the uncertainties of the weather forecast. Moreover, it estimates the power reduction in vulnerable lines due to changes in the series FACTS devices. The performance of the proposed optimization problem is tested on IEEE 14-, 30-, and 118-bus systems for several scenarios. The results are validated with the AC power flow results from MATPOWER.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Convex Relaxations of Maximal Load Delivery for Multi-Contingency Analysis of Joint Electric Power and Natural Gas Transmission Networks

Recent increases in gas-fired power generation have engendered increased interdependencies between natural gas and power transmission systems. These interdependencies have amplified existing vulnerabilities in gas and power grids, where disruptions can require the curtailment of load in one or both systems. Although typically operated independently, coordination of these systems during severe disruptions can allow for targeted delivery to lifeline services, including gas delivery for residential heating and power delivery for critical facilities. To address the challenge of estimating maximum joint network capacities under such disruptions, we consider the task of determining feasible steady-state operating points for severely damaged systems while ensuring the maximal delivery of gas and power loads simultaneously, represented mathematically as the nonconvex joint Maximal Load Delivery (MLD) problem. To increase its tractability, we present a mixed-integer convex relaxation of the MLD problem. Then, to demonstrate the relaxation’s effectiveness in determining bounds on network capacities, exact and relaxed MLD formulations are compared across various multi-contingency scenarios on nine joint networks ranging in size from 25 to 1191 nodes. The relaxation-based methodology is observed to accurately and efficiently estimate the impacts of severe joint network disruptions, often converging to the relaxed MLD problem’s globally optimal solution within ten seconds.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Model for Collaboration among Carriers to Reduce Empty Container Truck Trips

In recent years, intermodal transport has become an increasingly attractive alternative to freight shippers. However, the current intermodal freight transport is not as efficient as it could be. Oftentimes an empty container needs to be transported from the empty container depot to the shipper, and conversely, an empty container needs to be transported from the receiver to the empty container depot. These empty container movements decrease the freight carrier’s profit, as well as increase traffic congestion, decrease roadway safety, and add unnecessary emissions to the environment. To this end, our study evaluates a potential collaboration strategy to be used by carriers for domestic intermodal freight transport based on an optimization approach to reduce the number of empty container trips. A binary integer-linear programming model is developed to determine each freight carrier’s optimal schedule while minimizing its operating cost. The model ensures that the cost for each carrier with collaboration is less than or equal to its cost without collaboration. It also ensures that average savings from the collaboration are shared equally among all participating carriers. Additionally, two stochastic models are provided to account for uncertainty in truck travel times. The proposed collaboration strategy is tested using empirical data and is demonstrated to be effective in meeting all of the shipment constraints.

42 ENGINEERING↗