Search NASA⌕ Search

SEARCH · Search NASA

Results for “performance testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,765 records · Page 98

Design, fabrication, and operation of a test rig for high-speed tapered-roller bearings

A tapered-roller bearing test machine was designed, fabricated and successfully operated at speeds to 20,000 rpm. Infinitely variable radial loads to 26,690 N (6,000 lbs.) and thrust loads to 53,380 N (12,000 lbs.) can be applied to test bearings. The machine instrumentation proved to have the accuracy and reliability required for parametric bearing performance testing and has the capability of monitoring all programmed test parameters at continuous operation during life testing. This system automatically shuts down a test if any important test parameter deviates from the programmed conditions, or if a bearing failure occurs. A lubrication system was developed as an integral part of the machine, capable of lubricating test bearings by external jets and by means of passages feeding through the spindle and bearing rings into the critical internal bearing surfaces. In addition, provisions were made for controlled oil cooling of inner and outer rings to effect the type of bearing thermal management that is required when testing at high speeds.

Signer, H. R.↗

Digital control of high-intensity acoustic testing

To eliminate previous system instabilities and control high-intensity acoustic tests, a digital control vibration test system is modified by a software change. Three systems for the control of acoustic testing are compared: a hybrid digital/analog system, a digital vibration system, and the same digital vibration system modified by a software change to allow acoustic testing. It is shown that the hybrid system and the modified vibration system exhibit almost equal performance, although the hybrid system performs testing twice as fast. The development of a specialized acoustic test control system is justified since it costs far less than the general-purpose vibration control system. However, the latter is much easier to set up for a test, which is important in preventing overtesting of valuable spacecraft components.

Slusser, R. A.↗

The effect of simulated weightlessness on performance and mood

The performance results of the bedrest study at Ames were not what were expected. The Air Combat Maneuvering performance test was tested to assure its reliability. However, the results from this study show a continued increase in performance. One would assume that scores would become constant if not decrease by the first days of bedrest because an inverted position would affect performance. It is also interesting to observe that while the subject's moods deteriorated, their performance improved. Although the performance results were surprising, the mood results were as expected.

Rosenberg, Bonnie↗

The Space Station Photovoltaic Panels Plasma Interaction Test Program: Test plan and results

The Plasma Interaction Test performed on two space station solar array panels is addressed. This includes a discussion of the test requirements, test plan, experimental set-up, and test results. It was found that parasitic current collection was insignificant (0.3 percent of the solar array delivered power). The measured arcing threshold ranged from -210 to -457 V with respect to the plasma potential. Furthermore, the dynamic response of the panels showed the panel time constant to range between 1 and 5 microsec, and the panel capacitance to be between .01 and .02 microF.

Nahra, Henry K.↗

The Space Station photovoltaic panels plasma interaction test program - Test plan and results

The plasma Interaction Test performed on two space station solar array panels is addressed. This includes a discussion of the test requirements, test plan, experimental set-up, and test results. It was found that parasitic current collection was insignificant (0.3 percent of the solar array delivered power). The measured arcing threshold ranged from -210 to -457 V with respect to the plasma potential. Furthermore, the dynamic response of the panels showed the panel time constant to range between 1 and 5 microsec, and the panel capacitance to be between .01 and .02 microF.

Nahra, Henry K.↗

Testing of a Loop Heat Pipe with Two Evaporators and Two Condensers

Most existing Loop Heat Pipes (LHPs) consist of one single evaporator and one single condenser. LHPs with multiple evaporators will be very desirable for cooling multiple heat sources or a heat source with large thermal footprints. Extending the LHP technology to include multiple evaporators and multiple condensers faces some challenges, including the interaction between individual compensation chambers, operating temperature stability, and adaptability to rapid power and sink temperature transients. This paper describe extensive testing of an LHP with two evaporators and two condensers. Tests performed include start-up, power cycle, sink temperature cycle, reservoir temperature cycle, and capillary limit. Test results showed that the loop could operate successfully under various heat load and sink conditions. The loop operating temperature is a function of the total heat load, the heat load distribution between the two evaporators, and temperatures of the two condenser sinks. Under most conditions, only one reservoir contained two-phase fluid and the other reservoir was completely liquid filled. Moreover, control of the loop operating temperature could shift from one reservoir to the other as the test condition changed.

Ku, Jentung↗

Active Control of the Operating Temperature in a Loop Heat Pipe with Two Evaporators and Two Condensers

The operating temperature of a loop heat pipe (LHP) with multiple evaporators is a function of the total heat load, heat load distribution among evaporators, condenser temperature and ambient temperature. Because of the many variables involved, the operating temperature also showed more hystereses than an LHP with a single evaporator. Tight temperature control can be achieved by controlling its compensation chamber (CC) temperatures at the desired set point. This paper describes a test program on active control of the operating temperature in an LHP with two evaporators and two condensers. Temperature control was achieved by heating one or both CC's. Tests performed included start-up, power cycle, sink temperature cycle, CC temperature cycle, and capillary limit. Test results show that, regardless one or two CC's were heated to the set point temperature, one of CC's was always flooded with liquid. The loop could operate successfully at the desired set point temperature under most conditions, including some fast transients. At low heat loads, however, the CC temperature could suddenly increase above the set point temperature, possibly due to a sudden change of the vapor content inside the evaporator core.

Ku, Jentung↗

Return to Flight Resource Reel 1 of 2

A video presentation detailing the tests performed on the Space Shuttle Discovery in preparation for its return to flight is shown. The tests include: 1) Reinforced Carbon-Carbon (RCC) Impact Test Article; 2) RCC Foam Impact Testing; 3) Thermal Protection System (TPS) Ice Impact Testing featuring Justin Kerr, Project Engineer; 4) Wing Leading Edge Wireless Sensors featuring Karl Kiefer, President and CEO of Invocon, and Kevin Champaigne of Invocon; 5) TPS Repair Testing KC-135 Zero-G Environment featuring Soichi Noguchi, Mission Specialist; 6) TPS Extravehicular Activity Tool Demonstration; 7) TPS Repair Testing Vacuum Glove box; 8) TPS Repair Testing Human Thermal Vacuum Chamber; 9) TPS Reentry Testing Atmospheric Reentry Materials and Structures Evaluation Facility; 10) TPS Alternative Repair Concept; 11) Lora Bailey Lead Engineer for EVA Tools; 12) Reinforced Carbon-Carbon ATK Thiokol Plug Repair Animation; 13) 3-Percent Model Build-Up; and 14) Wind Tunnel Testing RCC Aging Research Ballistic Testing.

Source record↗

Return to Flight Resource Reel 2 of 2

A continuation of the tests performed on the Space Shuttle Discovery in preparation for its return to flight is presented. The tests include: 1) Shuttle Robot Arm Recertification; 2) Michael Hiltz Systems Group Leader; 3) Orbiter Boom Fabrication; 4) Orbiter Boom Final Development; 5) Gary Searle Manager of Orbiter Boom Sensor System (OBSS) Manufacturing and Assembly; 6) Orbiter Boom Qualification Unit; 7) STS-114 Crew Inspects Orbiter Boom at Kennedy Space Center; 8) Orbiter Boom Inspection of Thermal Protection System Animation; 9) External Tank Bipod Redesign; 10) External Tank Flange Redesign; 11) External Tank Bellows Redesign; 12) Shuttle Main Engine Testing and Delivery to Kennedy Space Center; 13) Ronnie Rigney Project Manager Space Shuttle Main Engine Program Office; 14) Gene Goldmman NASA Project Manager Space Shuttle Main Engine Project; 15) Mike Cosgrove Boeing-Rocketdyne Flow Manager; 16) Shuttle Rocket Booster Build-Up; 17) Ascent Imagery Improvements; and 18) STS-114 Flight Control Team and Mission Management Team.

Source record↗

Thermal Performance of a Low-Cost Loop Heat Pipe

This paper presents the thermal performance of a low-cost loop heat pipe (LHP) consisting of a single evaporator and a single condenser. The evaporator has an outer diameter of 14mm and a length of 50mm. An organic solvent was used as the working fluid. The low-cost LHP was made possible through a new manufacturing process. The LHP demonstrated excellent performance over heat loads ranging from 1W to 15OW and sink temperatures between 253K and 293K. Tests performed included start-up, power cycle, sink temperature cycle, high power and low power operations. No performance anomalies were seen.

Ku, Jentung↗

GENIE Flight Test Results and System Overview

NASA has envisioned a suite of lander test vehicles that will be flown in Earth s atmosphere to incrementally demonstrate applicable lunar lander performance in the terrestrial environment. As each terrestrial rocket progresses in maturity, relevant space flight technology matures to a higher technology readiness level, preparing it for inclusion on a future lunar lander design.. NASA s "Project M" lunar mission concept flew its first terrestrial rocket, RR1, in June 2010 in Caddo Mills, Texas. The Draper Laboratory built GENIE (Guidance Embedded Navigator Integration Environment) successfully demonstrated accurate, real time, embedded performance of Project M navigation and guidance algorithms in a highly dynamic environment. The RR1 vehicle, built by Armadillo Aerospace, performed a successful 60 second free flight and gave the team great confidence in Project M s highly reliable and robust GNC system design and implementation. This paper provides an overview of the GENIE system and describes recent flight performance test results onboard the RR1 terrestrial rocket.

Brady, Tye↗

Recent Progress in Entry Radiation Measurements in the NASA Ames Electric ARC Shock Tube Facility

The Electric Arc Shock Tube (EAST) at NASA Ames Research Center is NASA's only working shock tube capable of obtaining conditions representative of entry in a multitude of planetary atmospheres. The facility is capable of mapping spectroscopic signatures of a wide range of planetary entries from the Vacuum Ultraviolet through Mid-Wave Infrared (120-5500 nm). This paper summarizes the tests performed in EAST for Earth, Mars and Venus entries since 2008, then focuses on a specific test case for CO2/N2 mixtures. In particular, the paper will focus on providing information for the proper interpretation of the EAST data.

Cruden, Brett A.↗

Transition Detection at Cryogenic Temperatures Using a Carbon-Based Resistive Heating Layer Coupled with Temperature Sensitive Paint

This paper will highlight the development and application of a carbon-based resistive heating layer for use in transition detection at cryogenic temperatures at the National Transonic Facility (NTF) for full-flight Reynolds number testing. This study builds upon previous work that was successfully demonstrated at the 0.3-m Transonic Cryogenic Tunnel on a smaller-scale airfoil shape of regular geometry. However, the test performed at the NTF involved a semispan wing with complex geometry and significantly larger than previous tests. This required the development of new coatings to provide suitable resistances to provide adequate heating rates for transition detection. Successful implementation of this technology has the ability to greatly enhance transition detection experiments at cryogenic temperatures as well as reducing perturbation in the tunnel caused by more traditional transition detection methods.

Watkins, A. Neal↗

Characterization Testing of Lockheed Martin High-Power Micro Pulse Tube Cryocooler

This paper describes the thermal vacuum, microphonics, magnetics, and radiation testing and results of a Lockheed Martin high-power micro pulse tube cryocooler. The thermal performance of the microcooler was measured in vacuum for heat reject temperatures between 185 and 300 K. The cooler was driven with a Chroma 61602 AC power source for input powers ranging from 10 to 60 W and drive frequency between 115 and 140 Hz during thermal performance testing. The optimal drive frequency was dependent on both input power and heat reject temperature. In addition, the microphonics of the cooler were measured with the cooler driven by Iris Technologies LCCE-2 and HP-LCCE drive electronics for input powers ranging from 10 to 60 W and drive frequency between 135 and 145 Hz. The exported forces were strongly dependent on input power while only weakly dependent on the drive frequency. Moreover, the exported force in the compressor axis was minimized by closed loop control with the HP-LCCE. The cooler also survived a 500 krad radiation dose while being continuously operated with 30 W of input power at 220 K heat rejection temperature in vacuum. Finally, the DC and AC magnetic fields around the cooler were measured at various locations.

Rodriguez, Jose I.↗

Control of Ionomer Distribution in Roll-to-Roll Coated Fuel Cell Catalyst Layers

Fuel cell catalyst layers are a complex mixture of catalyst particles and ion-conducting polymers. The performance of catalyst layers is highly dependent on microstructure, which must balance proton and electron conduction with gas transport. As fuel cells transition from the laboratory to industrial production for vehicles and other applications, there is a need to understand how manufacturing processes impact the microstructure and, ultimately, the performance of catalyst layers. In this work, we have focused on the roll-to-roll coating of catalyst layers for proton exchange membrane fuel cells. The catalyst layers are responsible for the electrochemical reactions that enable power production. In these devices the catalyst is commonly a Pt nanoparticle supported on porous carbon blacks. The ion conducting polymer, or ionomer, is typically a perfluorosulfonic acid. The most common being Nafion. To fabricate the catalyst layer, the catalyst particles are dispersed in an ink with the ionomer and cast to form the catalyst layer. Commonly, laboratory samples are prepared using spray coating or hand painting, which effectively coat many thin layers to achieve the desired catalyst layer thickness. This creates catalyst layers with uniform distributions of materials throughout the thickness of the full catalyst layer. In contrast, roll-to-roll methods, like slot die, gravure or screen printing, coat the catalyst layer as a single wet film. As the film dries, ink constituents are able to segregate, leading to a heterogeneous distribution of materials through the thickness of the layer. It is also known that the choice of solvent and drying rate can affect the morphology of the catalyst layer. Thus, there is a need to understand how ink formulation and the drying process influence the distribution of materials and catalyst layer morphology. Here, we have explored the influence of solvent and drying rate on morphology of roll-to-roll coated catalyst layers. We show the development of the Kelvin probe method as a rapid screening technique for qualitative analysis of ionomer distribution. We also utilize nano X-ray computed tomography to visualize electrode structure and to quantify particle-size and pore-size distributions, thickness-dependent ionomer distribution, tortuosity, and effective transport properties. We find that solvent has a strong influence on ionomer distribution, with less of an effect on porosity. Conversely, drying temperature has a strong influence on porosity, but less influence on ionomer distribution. Finally, we utilize in situ fuel cell performance testing and other advanced diagnostics to quantify the impact of catalyst layer properties on fuel cell performance and demonstrate that roll-to-roll coating is capable of coating high performance catalyst layers in multi-meter lengths.

14 SOLAR ENERGY↗

Risk Informed Timelines (RIT) v.1.0

Risk Informed Timelines (RIT) is a more modern and holistic method for understanding how access delay timelines are developed and utilized in physical security system evaluations. The software utilizes Bayesian methods to combine subject matter expert judgement and small performance test datasets in a consistent and defensible way. It allows a more holistic view of delay performance that provides distributions of task times and task success probabilities to account for tasks that, if failed, would result in failure of the attack. The RIT methodology is meant to enable security risk managers to begin the transition into more comprehensive delay timeline analysis. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525. SAND2021-8294 O

Noel, ToddG.↗

Performance of Microreactor Test Article with Embedded Sensors During Testing in The Single Primary Heat Extraction and Removal Emulator

The nuclear industry is pursuing microreactors that can be factory assembled and deployed to remote regions for reliable power generation. One class of microreactors uses a monolithic metal core block coupled to heat pipes that use passive heat flow, increasing the surface area for heat transfer without requiring active coolant flow through the reactor core. Additional experimental testing is required to understand the heat rejection limitations of heat pipes and thermal stresses in the monolithic core block due to significant temperature gradients. This report describes the initial characterization and testing of a stainless-steel test article that was fabricated with embedded sensors to measure heat pipe performance limits, as well as spatially distributed temperatures and strains during electrically heated thermal testing to simulate nuclear heating. The electrically heated testing was performed in the Single Primary Heat Extraction and Removal Emulator facility located at Idaho National Laboratory. The ultimate goals of this work are to (1) accurately monitor temperature and strain distributions that result from differential thermal expansion in the test articles and (2) quantify the heat rejection limits of heat pipes as a function of operating temperature and working fluid during steady-state and transient operations. Initial tests focused on the feasibility of using advanced fiber-optic sensors and other sensor technologies to improve the understanding of temperature and strain distributions within the electrically heated experiments. However, these sensing capabilities could benefit the broader microreactor community if the sensors could be used to monitor component and system health during nuclear operations to inform a limited number of microreactor operators, ultimately reducing operation and maintenance costs and moving toward semiautonomous operation.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗