Search NASA⌕ Search

SEARCH · Search NASA

Results for “precision”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,765 records · Page 98

Precision measurement of the B0 meson lifetime using B0→J/ψK∗0 decays with the ATLAS detector

A measurement of the B0$$B^{0}$$ meson lifetime using B0→J/ψK∗0$$ B^{0} \rightarrow J/\psi K^{*0} $$ decays in data from 13 TeV$$\text {TeV}$$ proton–proton collisions with an integrated luminosity of 140fb-1$$ 140~\mathrm {fb^{-1}} $$ recorded by the ATLAS detector at the LHC is presented. The measured effective lifetime is τ=1.5053±0.0012(stat.)±0.0035(syst.)ps.$$ \tau = 1.5053\pm 0.0012~\mathrm {(stat.)} \pm 0.0035~\mathrm {(syst.)~ps}. $$The average decay width extracted from the effective lifetime, using parameters from external sources, is Γd=0.6639±0.0005(stat.)±0.0016(syst.)±0.0038(ext.)ps-1,$$\begin{aligned} \Gamma _d = 0.6639\pm 0.0005~\mathrm {(stat.)} \pm 0.0016~\mathrm {(syst.)}\\ \pm 0.0038~\text {(ext.)} \text {~ps}^{-1}, \end{aligned}$$where the uncertainties are statistical, systematic and from external sources. The earlier ATLAS measurement of Γs$$\Gamma _s$$ in the Bs0→J/ψϕ$$B^{0}_{s} \rightarrow J/\psi \phi $$ decay was used to derive a value for the ratio of the average decay widths Γd$$\Gamma _d$$ and Γs$$\Gamma _s$$ for B0$$B^{0} $$ and Bs0$$B^{0}_{s} $$ mesons respectively, of ΓdΓs=0.9905±0.0022(stat.)±0.0036(syst.)±0.0057(ext.).$$ \frac{\Gamma _d }{\Gamma _s } = 0.9905\pm 0.0022~\text {(stat.)} \pm 0.0036~\text {(syst.)} \pm 0.0057~\text {(ext.)}. $$The measured lifetime, average decay width and decay width ratio are in agreement with theoretical predictions and with measurements by other experiments. This measurement provides the most precise result of the effective lifetime of the B0$$B^{0}$$ meson to date.

Aad, G↗

A precise measurement of the jet energy scale derived from single-particle measurements and in situ techniques in proton–proton collisions at $\sqrt{s}=$ 13 TeV with the ATLAS detector

The jet energy calibration and its uncertainties are derived from measurements of the calorimeter response to single particles in both data and Monte Carlo simulation using proton–proton collisions at $\sqrt{s} = 13$ TeV collected with the ATLAS detector during Run 2 at the Large Hadron Collider. The jet calibration uncertainty for anti-$k_T$ jets with a jet radius parameter of R$_\textrm{jet} = 0.4$ and in the central jet rapidity region is about 2.5% for transverse momenta ($p_{\text {T}}$) of 20 $\text {GeV}$ , about 0.5% for $p_{\text {T}} = 300$ GeV and 0.7% for $p_{\text {T}} = 4$ TeV . Excellent agreement is found with earlier determinations obtained from -balance based in situ methods ($Z/\gamma$ +jets). The combination of these two independent methods results in the most precise jet energy measurement achieved so far with the ATLAS detector with a relative uncertainty of 0.3% at $p_\textrm{T} = 300$ GeV and 0.6% at 4 TeV. The jet energy calibration is also derived with the single-particle calorimeter response measurements separately for quark- and gluon-induced jets and furthermore for jets with R jet varying from 0.2 to 1.0 retaining the correlations between these measurements. Differences between inclusive jets and jets from boosted top-quark decays, with and without grooming the soft jet constituents, are also studied.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Precision dispersive approaches versus unitarized chiral perturbation theory for the lightest scalar resonances $\sigma /f_0(500) $ and $\kappa /K_0^*(700) $

For several decades, the $\sigma /f_0(500) $ and $\kappa /K_0^*(700) $ resonances have been subject to long-standing debate. Both their existence and properties were controversial until very recently. In this tutorial review, we compare model-independent dispersive and analytic techniques versus unitarized Chiral Perturbation Theory, when applied to the lightest scalar mesons $\sigma /f_0(500) $ and $\kappa /K_0^*(700) $. Here, the former have settled the long-standing controversy about the existence of these states, providing a precise determination of their parameters, whereas unitarization of chiral effective theories allows us to understand their nature, spectroscopic classification and dependence on QCD parameters. Here we review in a pedagogical way their uses, advantages and caveats.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

QCD precision measurements and structure function extraction at a high statistics, high energy neutrino scattering experiment: NuSOnG.

We extend the physics case for a new high-energy, ultra-high statistics neutrino scattering experiment, NuSOnG (Neutrino Scattering On Glass) to address a variety of issues including precision QCD measurements, extraction of structure functions, and the derived Parton Distribution Functions (PDF's). This experiment uses a Tevatron-based neutrino beam to obtain a sample of Deep Inelastic Scattering (DIS) events which is over two orders of magnitude larger than past samples. We outline an innovative method for fitting the structure functions using a parametrized energy shift which yields reduced systematic uncertainties. High statistics measurements, in combination with improved systematics, will enable NuSOnG to perform discerning tests of fundamental Standard Model parameters as we search for deviations which may hint of 'Beyond the Standard Model' physics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Computation and consequences of high order amplitude- and parameter-dependent tune shifts in storage rings for high precision measurements

Nonlinear effects of the various electric field and magnetic field components of storage rings to confine the particles and bend their trajectory can cause substantial amplitude-dependent tune shifts within the beam. Furthermore, tune shifts are often sensitive to variations of system parameters, e.g. total particle momentum offsets $δp$. Such amplitude- and parameter-dependent tune shifts influence the dynamics and stability of a beam in particle storage rings. Thus, it is critical for high precision measurements to analyze and understand these influences. On this basis, we present in this paper normal form methods for the calculation of high order amplitude and system parameter dependencies of the horizontal and vertical tunes in storage rings using the differential algebra (DA) framework within COSY INFINITY. A storage ring is simulated using COSY INFINITY to generate a DA Poincaré return map describing the transverse phase space behavior after each revolution in the storage ring. The map is expanded around the parameter-dependent closed orbit of the system before transforming the resulting map into normal form coordinates to extract the high order tune dependencies on the phase space amplitude and variation in the system parameters. As a specific example, a storage ring similar to the Storage Ring of the Muon g-2 Experiment at Fermilab (E989) is investigated.

43 PARTICLE ACCELERATORS↗

Precise 3D Track Reconstruction Algorithm for the ICARUS T600 Liquid Argon Time Projection Chamber Detector

Liquid Argon Time Projection Chamber (LAr TPC) detectors offer charged particle imaging capability with remarkable spatial resolution. Precise event reconstruction procedures are critical in order to fully exploit the potential of this technology. In this paper we present a new, general approach to 3D reconstruction for the LAr TPC with a practical application to the track reconstruction. The efficiency of the method is evaluated on a sample of simulated tracks. We present also the application of the method to the analysis of stopping particle tracks collected during the ICARUS T600 detector operation with the CNGS neutrino beam.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

HD-Bind: Encoding of Molecular Structure with Low Precision, Hyperdimensional Binary Representations

Publicly available collections of drug-like molecules have grown to comprise tens of billions of compounds due to advances in combinatorial chemistry. Traditional methods for identifying "hit" molecules from a large collection of potential drug-like candidates have relied on biophysical theory to compute approximations to the Gibbs free energy of the binding interaction between the drug and its protein target. These approaches have the major drawback that they require exceptional computing capabilities for even relatively small collections of molecules. Hyperdimensional Computing (HDC) is a recently-proposed learning paradigm that represents data with high-dimension binary vectors; this allows the use of low-precision binary vector arithmetic to create models of the data that can be learned without the need for the gradient-based optimization required in many conventional machine learning and deep learning methods. This algorithmic simplicity allows for acceleration in hardware that has been previously demonstrated in a range of application areas. We consider existing HDC approaches for molecular property classification and introduce two novel encodings of a commonly-used molecular representation, the extended connectivity fingerprint (ECFP). We show that HDC-based inference methods are as much as 91 times more efficient than traditional machine learning methods, and achieve an acceleration of nearly nine orders of magnitude compared to molecular docking. Our results show that HDC accelerated methods retain competitive accuracy on a number of well-studied tasks such as molecular property predictions using the MoleculeNet dataset, and bind/no-bind activity classification using the DUD-E and LIT-PCBA datasets. Our work thus motivates further investigation into molecular representation learning to develop ultraefficient pre-screening tools.

Jones, William↗

Precancer Atlas to Drive Precision Prevention Trials

Cancer development is a complex process driven by inherited and acquired molecular and cellular alterations. Prevention is the holy grail of cancer elimination, but making this a reality will take a fundamental rethinking and deep understanding of premalignant biology. Here, we propose a national concerted effort to create a Precancer Atlas (PCA), integrating multi-omics and immunity – basic tenets of the neoplastic process. The biology of neoplasia caused by germline mutations has led to paradigm-changing precision prevention efforts, including: tumor testing for mismatch repair (MMR) deficiency in Lynch syndrome establishing a new paradigm, combinatorial chemoprevention efficacy in familial adenomatous polyposis (FAP), signal of benefit from imaging-based early detection research in high-germline risk for pancreatic neoplasia, elucidating early ontogeny in BRCA1-mutation carriers leading to an international breast cancer prevention trial, and insights into the intricate germline-somatic-immunity interaction landscape. Emerging genetic and pharmacologic (metformin) disruption of mitochondrial (mt) respiration increased autophagy to prevent cancer in a Li-Fraumeni mouse model (biology reproduced in clinical pilot) and revealed profound influences of subtle changes in mt DNA background variation on obesity, aging, and cancer risk. The elaborate communication between the immune system and neoplasia includes an increasingly complex cellular microenvironment and dynamic interactions between host genetics, environmental factors, and microbes in shaping the immune response. Cancer vaccines are in early murine and clinical precancer studies, building on the recent successes of immunotherapy and HPV vaccine immune prevention. Molecular monitoring in Barrett's esophagus to avoid overdiagnosis/treatment highlights an important PCA theme. Next generation sequencing (NGS) discovered age-related clonal hematopoiesis of indeterminate potential (CHIP). Ultra-deep NGS reports over the past year have redefined the premalignant landscape remarkably identifying tiny clones in the blood of up to 95% of women in their 50s, suggesting that potentially premalignant clones are ubiquitous. Similar data from eyelid skin and peritoneal and uterine lavage fluid provide unprecedented opportunities to dissect the earliest phases of stem/progenitor clonal (and microenvironment) evolution/diversity with new single-cell and liquid biopsy technologies. Cancer mutational signatures reflect exogenous or endogenous processes imprinted over time in precursors. In conclusion, accelerating the prevention of cancer will require a large-scale, longitudinal effort, leveraging diverse disciplines (from genetics, biochemistry, and immunology to mathematics, computational biology, and engineering), initiatives, technologies, and models in developing an integrated multi-omics and immunity PCA – an immense national resource to interrogate, target, and intercept events that drive oncogenesis.

59 BASIC BIOLOGICAL SCIENCES↗

BCL10 Mutations Define Distinct Dependencies Guiding Precision Therapy for DLBCL

Activated B cell–like diffuse large B-cell lymphomas (ABC-DLBCL) have unfavorable outcomes and chronic activation of CARD11–BCL10–MALT1 (CBM) signal amplification complexes that form due to polymerization of BCL10 subunits, which is affected by recurrent somatic mutations in ABC-DLBCLs. Herein, we show that BCL10 mutants fall into at least two functionally distinct classes: missense mutations of the BCL10 CARD domain and truncation of its C-terminal tail. Truncating mutations abrogated a motif through which MALT1 inhibits BCL10 polymerization, trapping MALT1 in its activated filament-bound state. CARD missense mutations enhanced BCL10 filament formation, forming glutamine network structures that stabilize BCL10 filaments. Mutant forms of BCL10 were less dependent on upstream CARD11 activation and thus manifested resistance to BTK inhibitors, whereas BCL10 truncating but not CARD mutants were hypersensitive to MALT1 inhibitors. Therefore, BCL10 mutations are potential biomarkers for BTK inhibitor resistance in ABC-DLBCL, and further precision can be achieved by selecting therapy based on specific biochemical effects of distinct mutation classes.

60 APPLIED LIFE SCIENCES↗

Visual inspection reliability for precision manufactured parts

Sandia National Laboratories conducted an experiment for the National Nuclear Security Administration to determine the reliability of visual inspection of precision manufactured parts used in nuclear weapons. In addition visual inspection has been extensively researched since the early 20th century; however, the reliability of visual inspection for nuclear weapons parts has not been addressed. In addition, the efficacy of using inspector confidence ratings to guide multiple inspections in an effort to improve overall performance accuracy is unknown. Further, the workload associated with inspection has not been documented, and newer measures of stress have not been applied.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Numerical eigen-spectrum slicing, accurate orthogonal eigen-basis, and mixed-precision eigenvalue refinement using OpenMP data-dependent tasks and accelerator offload

Performing a variety of numerical computations efficiently and, at the same time, in a portable fashion requires both an overarching design followed by a number of implementation strategies. All of these are exemplified below as we present transitioning the PLASMA numerical library from relying on dependence-driven large tasks to achieving utilization of fine grain tasking and offload to hardware accelerators while keeping its core dependence sets: OpenMP source code pragmas and runtime for most system-level functionality and basic low-level numerical kernels provided directly by hardware vendors or open source projects with vendor contributions. We also present new algorithmic methods and their efficient parallel implementations including fine grained tasking for eigen-spectrum slicing and offload for mixed-precision eigenvalue refinement. We provide performance, scaling, and numerical results showing sizable gains over the available solutions from either the open source and vendor-provided packages.

Luszczek, Piotr↗

Ion microscopy with resonant ionization mass spectrometry : time-of-flight depth profiling with improved isotopic precision.

There are four generally mutually exclusive requirements that plague many mass spectrometric measurements of trace constituents: (1) the small size (limited by the depth probed) of many interesting materials requires high useful yields to simply detect some trace elements, (2) the low concentrations of interesting elements require efficient discrimination from isobaric interferences, (3) it is often necessary to measure the depth distribution of elements with high surface and low bulk contributions, and (4) many applications require precise isotopic analysis. Resonant ionization mass spectrometry has made dramatic progress in addressing these difficulties over the past five years.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Improving precision and accuracy of genetic mapping with genotyping-by-sequencing data in outcrossing species

This dataset contains all data and supplementary materials from "Improving precision and accuracy of genetic mapping with genotyping-by-sequencing data in outcrossing species". An Excel file a list of all QTLs and linkage group length (in cM) obtained with two different SNP-calling methods (Tassel-Uneak and Tassel-GBS), genetic map-construction method (linkage-only and reference order-corrected) and depth filters (12x, 20x, 30x and 40x) for genetic mapping of 18 biomass yield traits in a biparental Miscanthus sinensis population using RAD-Seq SNPs is provided as "Supplementary file 1". A Perl script with the code for filtering VCF and HapMap-formatted data files is provided as “Supplementary file 2”. Phenotype data used for QTL mapping is provided as “Supplementary File 3”. A Perl script with the code for the simulation study is provided as “Supplementary file 4”.

GenotypingSimulator↗

Precise 3D reactor core calculation using spherical harmonics and discontinuous Galerkin finite element methods

We study the use of P{sub N} method in angle and discontinuous Galerkin is space to solve 3D neutron transport problem. P{sub N} method consists in developing the angular flux on truncated spherical harmonics basic. In this paper, we couple this method with the discontinuous finite elements in space to obtain a complete discretization of the multigroup neutron transport equation. To investigate its precision, the method was applied to Takeda and C5G7 benchmark problems. These calculations point out that the proposed P{sub N}-DG method is capable of producing accurate solutions in small computational time, and that it is able to handle complex 3D geometries. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Study on the precision of the multiaperture scintillation sensor turbulence profiler (MASS) employed in the site testing campaign for the Thirty Meter Telescope

The multiaperture scintillation sensor (MASS) has become a device widely employed to measure the altitude distribution of atmospheric turbulence. An empirical study is reported that investigates the dependence of the MASS results on the knowledge of the instrumental parameters. Also, the results of a side-by-side comparison of two MASS instruments are presented, indicating that MASS instruments permit measurements of the integrated seeing to a precision better than 0.05 arc sec and of the individual turbulence layer strength Cn{sup 2}(h)dh to better than 10{sup -14} m{sup 1/3}.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Precision refractive index measurements of air, N2, O2, Ar, and CO2 with a frequency comb

We report precision measurements of the refractive indices of dry air, N2, O2, Ar, and CO2, performed by using a frequency comb as the light source in a Mach-Zehnder interferometer setup. Improved dispersion formulas for all gases are derived with a sensitivity level of 10{sup -9}. These results are valid for a wavelength range from 740 to 860 nm and are in good agreement with measurements from other groups.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Dual-wavelength low-coherence instantaneous phase-shifting interferometer to measure the shape of a segmented mirror with subnanometer precision

We present a noncontact optical metrology measuring the pistons and tip/tilt angles of the 61 hexagonal segments of a compact-sized segmented mirror. The instrument has been developed within the scope of a design study for the European Extremely Large Telescope (E-ELT). It is used as reference sensor for cophasing of the mirror segments in closed-loop control. The mirror shape is also measured by different types of stellar light-based phasing cameras whose performances will be evaluated with regard to a future E-ELT. Following a description of the system architecture, the second part of the paper presents experimental results demonstrating the achieved precision: 0.48 nm rms in piston and 74 nrad rms in tip/tilt.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Increased phase precision of spatial light modulators using irrational slopes: application to attosecond metrology

The ability of spatial light modulators (SLMs) to modify the amplitude and phase of light has proved them invaluable to the optics and photonics community. In many applications, the bit-depth of SLMs is a major limiting factor dictated by a digital processor. As a result, there is usually a compromise between refresh speed and bit-depth. Here, we present a method to increase the effective bit-depth of SLMs, which utilizes a linear slope, as is commonly applied to deal with the zeroth-order effect. This technique was tested using two interferometric transient absorption spectroscopy setups. Through the high harmonic generation in gases producing a train of attosecond pulses and harmonics from solids in the ultraviolet, two pulses are generated that interfere in the far field providing a measurement of the optical phase. An increase in the precision far beyond the limit dictated by the digital processor in the bit-depth was found.

Harrison, Geoffrey R. (ORCID:0000000152141866)↗