Search NASA⌕ Search

SEARCH · Search NASA

Results for “programmable”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,765 records · Page 98

Key differentiators influencing the choice of robust shielded containers

The NDA's Upstream Optioneering project has examined the potential implications of using an alternative type of waste package and its influence on the waste management lifecycle across the NDA estate. Robust Shielded Containers (RSCs) are radioactive waste packages that provide integral radiological shielding, reducing the need for remote handling. The robustness of the container could remove the need to immobilise waste by cement encapsulation. RSCs are routinely used to package ILW for interim storage in Germany and have fairly recently been considered for use in the UK because RSCs have the potential to simplify the waste management lifecycle and enable risk and hazard reduction. In particular, the current baseline (included in Magnox Limited lifetime plans) follows the strategy set out in the Magnox Operating Decommissioning Programme (MODP), in which Type II MOSAIK and Type VI Ductile Cast Iron Containers (DCICs) are used to package (in non-encapsulated form) most Magnox ILW arising prior to 2050. By considering representative types of Intermediate Level Waste (ILW) and exploring potential packaging options for these wastes, this paper identifies the factors that could differentiate between cases in which RSCs would, or would not, be an appropriate option. The potential role of RSCs across the waste management lifecycle is examined, from retrieval of waste through to emplacement at a Geological Disposal Facility (GDF), including consideration of other potential uses of RSCs, such as temporary storage of raw wastes for which appropriate treatment and conditioning measures have yet to be developed. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

An integrated approach to geological disposal of UK wastes containing carbon-14

Carbon-14 is a key radionuclide in the assessment of the safety of a geological disposal facility for radioactive waste because of the calculated assessment of the radiological consequences of gaseous carbon-14 bearing species [i]. It may be that such calculations are based on overly conservative assumptions and that better understanding could lead to considerably reduced assessment of the radiological consequences from these wastes. Alternatively, it may be possible to mitigate the impact of these wastes through alternative treatment, packaging or design options. The Radioactive Waste Management Directorate of the UK's Nuclear Decommissioning Authority (NDA RWMD) has established an integrated project team in which the partners are working together to develop a holistic approach to carbon-14 management in the disposal system [ii]. For a waste stream containing carbon-14 to be an issue: There must be a significant inventory of carbon-14 in the waste stream; and That waste stream has to generate carbon-14 bearing gas; and a bulk gas phase has to entrain the carbon-14 bearing gas: and these gases must migrate through the engineered barriers in significant quantities; and these gases must migrate through the overlying geological environment (either as a distinct gas phase or as dissolved gas); and these gases must interact with materials in the biosphere (i.e. plants) in a manner that leads to significant doses and risks to exposed groups or potentially exposed groups. The project team has developed and used this 'and' approach to structure and prioritise the technical work and break the problem down in a manageable way. We have also used it to develop our approach to considering alternative treatment, packaging and design options. For example, it may be possible to pre-treat some wastes to remove some of the inventory or to segregate other wastes so that they are removed from any bulk gas phase which might facilitate migration through the geosphere. Initially, the project team has undertaken a six month programme of work to examine the current understanding of these aspects and has captured this in the Phase 1 report [ii], in a modelling basis spreadsheet and in scoping assessments, which help us better understand the potential significance of carbon-14. Using the current modelling basis, but ignoring any potential benefits from the geosphere in retarding or preventing gas from reaching the surface, the calculated release of carbon- 14 is dominated by: corrosion of irradiated reactive metals (in the operational and early post-closure time frame); corrosion of irradiated stainless steel and leaching of irradiated graphite (in the longer term). The Phase 1 work has shown that there is considerable scope for reducing the calculated radiological consequence for these wastes and a roadmap has been developed for a second Phase of work. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Peel-and-Stick Sensors Powered by Directed RF Energy

PARC, a Xerox Company, is developing a low-cost system of peel-and-stick wireless sensors that will enable widespread building environment sensor deployment with the potential to deliver up to 30% energy savings. The system is embodied by a set of RF hubs that provide power to automatically located sensor nodes, and relay data wirelessly to the building management system (BMS). The sensor nodes are flexible electronic labels powered by rectified RF energy transmitted by an RF hub and can contain multiple printed and conventional sensors. The system design overcomes limitations in wireless sensors related to power delivery, lifetime, and cost by eliminating batteries and photovoltaic devices. Sensor localization is performed automatically by the inclusion of a programmable multidirectional antenna array in the RF hub. Comparison of signal strengths while the RF beam is swept allows for sensor localization, reducing installation effort and enabling automatic recommissioning of sensors that have been relocated, overcoming a significant challenge in building operations. PARC has already demonstrated wireless power and temperature data transmission up to a distance of 20m with less than one minute between measurements, using power levels well within the FCC regulation limits in the 902-928 MHz ISM band. The sensor’s RF energy harvesting antenna achieves high performance with dimensions below 5cm x 9cm

Lalau-Keraly, Christopher↗

Open Source Scanning Probe Microscopy Control Software package GXSM

GXSM is a full featured and modern scanning probe microscopy (SPM) software. It can be used for powerful multidimensional image/data processing, analysis, and visualization. Connected to an instrument, it is operating many different flavors of SPM, e.g., scanning tunneling microscopy and atomic force microscopy or, in general, two-dimensional multichannel data acquisition instruments. The GXSM core can handle different data types, e.g., integer and floating point numbers. An easily extendable plug-in architecture provides many image analysis and manipulation functions. A digital signal processor subsystem runs the feedback loop, generates the scanning signals, and acquires the data during SPM measurements. The programmable GXSM vector probe engine performs virtually any thinkable spectroscopy and manipulation task, such as scanning tunneling spectroscopy or tip formation. The GXSM software is released under the GNU general public license and can be obtained via the internet.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

A broader view on EUV-masks: adding complementary imaging modes to the SHARP microscope

The authors are expanding the capabilities of the SHARP microscope by implementing complementary imaging modes. SHARP (the SEMATECH High-NA Actinic Reticle review Project) is an actinic, synchrotron-based microscope dedicated to extreme ultraviolet (EUV) photomask research. SHARP’s programmable Fourier Synthesis Illuminator and its use of Fresnel zoneplate lenses as imaging optics provide a versatile framework, facilitating the implementation of diverse modes beyond conventional imaging. In addition to SHARP’s set of standard zoneplates, we have created more than 100 zoneplates for complementary imaging modes, all designed to extract additional information from photomasks, improve navigation and enhance defect detection. More than 50 new zoneplates are installed in the tool; the remaining lenses are currently in production. Here in this paper we discuss the design and fabrication of zoneplates for complementary imaging modes and present image data, obtained using Zernike Phase Contrast and different implementations of Differential Interference Contrast.

36 MATERIALS SCIENCE↗

Current Trends in Gamma Radiation Detection for Radiological Emergency Response

Passive and active detection of gamma rays from shielded radioactive materials, including special nuclear materials, is an important task for any radiological emergency response organization. This article reports on the current trends and status of gamma radiation detection objectives and measurement techniques as applied to nonproliferation and radiological emergencies. In recent years, since the establishment of the Domestic Nuclear Detection Office by the Department of Homeland Security, a tremendous amount of progress has been made in detection materials (scintillators, semiconductors), imaging techniques (Compton imaging, use of active masking and hybrid imaging), data acquisition systems with digital signal processing, field programmable gate arrays and embedded isotopic analysis software (viz. gamma detector response and analysis software [GADRAS]1), fast template matching, and data fusion (merging radiological data with geo-referenced maps, digital imagery to provide better situational awareness). In this stride to progress, a significant amount of interdisciplinary research and development has taken place–techniques and spin-offs from medical science (such as x-ray radiography and tomography), materials engineering (systematic planned studies on scintillators to optimize several qualities of a good scintillator, nanoparticle applications, quantum dots, and photonic crystals, just to name a few). No trend analysis of radiation detection systems would be complete without mentioning the unprecedented strategic position taken by the National Nuclear Security Administration (NNSA) to deter, detect, and interdict illicit trafficking in nuclear and other radioactive materials across international borders and through the global maritime transportation–the so-called second line of defense.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effects of residual target motion for image-tracked spine radiosurgery

A quality assurance method was developed to investigate the effects of residual target motion for hypofractionated spine radiosurgery. The residual target motion (target movement between successive image-guided corrections) was measured on-line via dual x-ray imagers for patients treated with CyberKnife (Accuray, Inc., Sunnyvale, CA), a robotic linear accelerator with intrafractional image-tracking capability. The six degree-of-freedom characteristics of the residual target motion were analyzed, the effects of such motion on patient treatment delivery were investigated by incorporating the probability distribution of the residual motion into the treatment planning dose calculations, and deviations of the doses from those originally planned were calculated. Measurements using a programmable motion phantom were also carried out and compared with the static treatment plan calculations. It was found that the residual target motions were patient specific and typically on the order of 2 mm. The measured dose distributions incorporating the residual target motion also exhibited 2.0 mm discrepancy at the prescription isodose level when compared with the static treatment plan calculations. For certain patients, residual errors introduced significant uncertainties ({approx}1 Gy) for the dose delivered to the spinal cord, especially at the high dose levels covering a small volume of the spinal cord (e.g., 0.1 cc). In such cases, stringent cord constraints and frequent monitoring of the target position should be implemented.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Benchmarking a novel ultrasound-CT fusion system for respiratory motion management in radiotherapy: Assessment of spatio-temporal characteristics and comparison to 4DCT

Management of respiratory motion during radiation therapy requires treatment planning and simulation using imaging modalities that possess sufficient spatio-temporal accuracy and precision. An investigation into the use of a novel ultrasound (United States) imaging system for assessment of respiratory motion is presented, exploiting its good soft tissue contrast and temporal precision. The system dynamically superimposes the appropriate image plane sampled from a reference CT data set with the corresponding US B-mode image. An articulating arm is used for spatial registration. While the focus of the study was to quantify the system's ability to track respiratory motion, certain unique spatial calibration procedures were devised that render the software potentially valuable to the general research community. These include direct access to all transformation matrix elements and image scaling factors, a manual latency correction function, and a three-point spatial registration procedure that allows the system to be used in any room possessing a traditional radiotherapy laser localization system. Counter-intuitively, it was discovered that a manual procedure for calibrating certain transformation matrix elements produced superior accuracy to that of an algorithmic Levenberg-Marquardt optimization method. The absolute spatial accuracy was verified by comparing the physical locations of phantom test objects measured using the spatially registered US system, and using data from a 3DCT scan of the phantom as a reference. The spatial accuracy of the display superposition was also tested in a similar manner. The system's dynamic properties were then assessed using three methods. First, the overall system response time was studied using a programmable motion phantom. This included US video update, articulating arm update, CT data set resampling, and image display. The next investigation verified the system's ability to measure the range of motion of a moving anatomical test phantom that possessed both high and low contrast test objects. Finally, the system's performance was compared to that of a four-dimensional CT (4DCT) data set. The absolute spatial and display superposition accuracy was found to be better than 2 mm and typically 1 mm. Overall dynamic system response was adequate to produce a mean relative positional error of less than 1 mm if an empiric latency correction of 3 video frames was incorporated. The dynamic CT/US display mode was able to assess phantom motion for both high and low contrast test objects to within 1 mm, and compared favorably to the 4DCT data. The 4DCT movie loop accurately assessed the target motion for both of the high and low contrast objects tested, but the minimum intensity and average intensity reconstructions did not. This investigation demonstrated that this US system possesses sufficient spatio-temporal accuracy to properly assess respiratory motion. Future work will seek to demonstrate efficacy in its clinical application to respiratory motion assessment, particularly for sites in the upper abdomen, where low tissue contrast is evident.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Tumor trailing strategy for intensity-modulated radiation therapy of moving targets

Internal organ motion during the course of radiation therapy of cancer affects the distribution of the delivered dose and, generally, reduces its conformality to the targeted volume. Previously proposed approaches aimed at mitigating the effect of internal motion in intensity-modulated radiation therapy (IMRT) included expansion of the target margins, motion-correlated delivery (e.g., respiratory gating, tumor tracking), and adaptive treatment plan optimization employing a probabilistic description of motion. We describe and test the tumor trailing strategy, which utilizes the synergy of motion-adaptive treatment planning and delivery methods. We regard the (rigid) target motion as a superposition of a relatively fast cyclic component (e.g., respiratory) and slow aperiodic trends (e.g., the drift of exhalation baseline). In the trailing approach, these two components of motion are decoupled and dealt with separately. Real-time motion monitoring is employed to identify the 'slow' shifts, which are then corrected by applying setup adjustments. The delivery does not track the target position exactly, but trails the systematic trend due to the delay between the time a shift occurs, is reliably detected, and, subsequently, corrected. The ''fast'' cyclic motion is accounted for with a robust motion-adaptive treatment planning, which allows for variability in motion parameters (e.g., mean and extrema of the tidal volume, variable period of respiration, and expiratory duration). Motion-surrogate data from gated IMRT treatments were used to provide probability distribution data for motion-adaptive planning and to test algorithms that identified systematic trends in the character of motion. Sample IMRT fields were delivered on a clinical linear accelerator to a programmable moving phantom. Dose measurements were performed with a commercial two-dimensional ion-chamber array. The results indicate that by reducing intrafractional motion variability, the trailing strategy enhances relevance and applicability of motion-adaptive planning methods, and improves conformality of the delivered dose to the target in the presence of irregular motion. Trailing strategy can be applied to respiratory-gated treatments, in which the correction for the slow motion can increase the duty cycle, while robust probabilistic planning can improve management of the residual motion within the gate window. Similarly, trailing may improve the dose conformality in treatment of patients who exhibit detectable target motion of low amplitude, which is considered insufficient to provide a clinical indication for the use of respiratory-gated treatment (e.g., peak-to-peak motion of less than 10 mm). The mechanical limitations of implementing tumor trailing are less rigorous than those of real-time tracking, and the same technology could be used for both.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Direct-conversion flat-panel imager with avalanche gain: Feasibility investigation for HARP-AMFPI

The authors are investigating the concept of a direct-conversion flat-panel imager with avalanche gain for low-dose x-ray imaging. It consists of an amorphous selenium (a-Se) photoconductor partitioned into a thick drift region for x-ray-to-charge conversion and a relatively thin region called high-gain avalanche rushing photoconductor (HARP) in which the charge undergoes avalanche multiplication. An active matrix of thin film transistors is used to read out the electronic image. The authors call the proposed imager HARP active matrix flat panel imager (HARP-AMFPI). The key advantages of HARP-AMFPI are its high spatial resolution, owing to the direct-conversion a-Se layer, and its programmable avalanche gain, which can be enabled during low dose fluoroscopy to overcome electronic noise and disabled during high dose radiography to prevent saturation of the detector elements. This article investigates key design considerations for HARP-AMFPI. The effects of electronic noise on the imaging performance of HARP-AMFPI were modeled theoretically and system parameters were optimized for radiography and fluoroscopy. The following imager properties were determined as a function of avalanche gain: (1) the spatial frequency dependent detective quantum efficiency; (2) fill factor; (3) dynamic range and linearity; and (4) gain nonuniformities resulting from electric field strength nonuniformities. The authors results showed that avalanche gains of 5 and 20 enable x-ray quantum noise limited performance throughout the entire exposure range in radiography and fluoroscopy, respectively. It was shown that HARP-AMFPI can provide the required gain while maintaining a 100% effective fill factor and a piecewise dynamic range over five orders of magnitude (10{sup -7}-10{sup -2} R/frame). The authors have also shown that imaging performance is not significantly affected by the following: electric field strength nonuniformities, avalanche noise for x-ray energies above 1 keV and direct interaction of x rays in the gain region. Thus, HARP-AMFPI is a promising flat-panel imager structure that enables high-resolution fully quantum noise limited x-ray imaging over a wide exposure range.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Prospective-gated cardiac micro-CT imaging of free-breathing mice using carbon nanotube field emission x-ray

Purpose: Carbon nanotube (CNT) based field emission x-ray source technology has recently been investigated for diagnostic imaging applications because of its attractive characteristics including electronic programmability, fast switching, distributed source, and multiplexing. The purpose of this article is to demonstrate the potential of this technology for high-resolution prospective-gated cardiac micro-CT imaging. Methods: A dynamic cone-beam micro-CT scanner was constructed using a rotating gantry, a stationary mouse bed, a flat-panel detector, and a sealed CNT based microfocus x-ray source. The compact single-beam CNT x-ray source was operated at 50 KVp and 2 mA anode current with 100 {mu}mx100 {mu}m effective focal spot size. Using an intravenously administered iodinated blood-pool contrast agent, prospective cardiac and respiratory-gated micro-CT images of beating mouse hearts were obtained from ten anesthetized free-breathing mice in their natural position. Four-dimensional cardiac images were also obtained by gating the image acquisition to different phases in the cardiac cycle. Results: High-resolution CT images of beating mouse hearts were obtained at 15 ms temporal resolution and 6.2 lp/mm spatial resolution at 10% of system MTF. The images were reconstructed at 76 {mu}m isotropic voxel size. The data acquisition time for two cardiac phases was 44{+-}9 min. The CT values observed within the ventricles and the ventricle wall were 455{+-}49 and 120{+-}48 HU, respectively. The entrance dose for the acquisition of a single phase of the cardiac cycle was 0.10 Gy. Conclusions: A high-resolution dynamic micro-CT scanner was developed from a compact CNT microfocus x-ray source and its feasibility for prospective-gated cardiac micro-CT imaging of free-breathing mice under their natural position was demonstrated.

60 APPLIED LIFE SCIENCES↗

Dynamic volume vs respiratory correlated 4DCT for motion assessment in radiation therapy simulation

Purpose: Conventional (i.e., respiratory-correlated) 4DCT exploits the repetitive nature of breathing to provide an estimate of motion; however, it has limitations due to binning artifacts and irregular breathing in actual patient breathing patterns. The aim of this work was to evaluate the accuracy and image quality of a dynamic volume, CT approach (4D{sub vol}) using a 320-slice CT scanner to minimize these limitations, wherein entire image volumes are acquired dynamically without couch movement. This will be compared to the conventional respiratory-correlated 4DCT approach (RCCT). Methods: 4D{sub vol} CT was performed and characterized on an in-house, programmable respiratory motion phantom containing multiple geometric and morphological ''tumor'' objects over a range of regular and irregular patient breathing traces obtained from 3D fluoroscopy and compared to RCCT. The accuracy of volumetric capture and breathing displacement were evaluated and compared with the ground truth values and with the results reported using RCCT. A motion model was investigated to validate the number of motion samples needed to obtain accurate motion probability density functions (PDF). The impact of 4D image quality on this accuracy was then investigated. Dose measurements using volumetric and conventional scan techniques were also performed and compared. Results: Both conventional and dynamic volume 4DCT methods were capable of estimating the programmed displacement of sinusoidal motion, but patient breathing is known to not be regular, and obvious differences were seen for realistic, irregular motion. The mean RCCT amplitude error averaged at 4 mm (max. 7.8 mm) whereas the 4D{sub vol} CT error stayed below 0.5 mm. Similarly, the average absolute volume error was lower with 4D{sub vol} CT. Under irregular breathing, the 4D{sub vol} CT method provides a close description of the motion PDF (cross-correlation 0.99) and is able to track each object, whereas the RCCT method results in a significantly different PDF from the ground truth, especially for smaller tumors (cross-correlation ranging between 0.04 and 0.69). For the protocols studied, the dose measurements were higher in the 4D{sub vol} CT method (40%), but it was shown that significant mAs reductions can be achieved by a factor of 4-5 while maintaining image quality and accuracy. Conclusions: 4D{sub vol} CT using a scanner with a large cone-angle is a promising alternative for improving the accuracy with which respiration-induced motion can be characterized, particularly for patients with irregular breathing motion. This approach also generates 4DCT image data with a reduced total scan time compared to a RCCT scan, without the need for image binning or external respiration signals within the 16 cm scan length. Scan dose can be made comparable to RCCT by optimization of the scan parameters. In addition, it provides the possibility of measuring breathing motion for more than one breathing cycle to assess stability and obtain a more accurate motion PDF, which is currently not feasible with the conventional RCCT approach.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-J-211: Design and Study of In-House Software Based Respiratory Motion Monitoring, Controlling and Breath-Hold Device for Gated Radiotherapy

Purpose: The purpose of this present work was to fabricate an in-house software based respiratory monitoring, controlling and breath-hold device using computer software programme which guides the patient to have uniform breath hold in response to request during the gated radiotherapy. Methods: The respiratory controlling device consists of a computer, inhouse software, video goggles, a highly sensitive sensor for measurement of distance, mounting systems, a camera, a respiratory signal device, a speaker and a visual indicator. The computer is used to display the respiratory movements of the patient with digital as well as analogue respiration indicators during the respiration cycle, to control, breath-hold and analyze the respiratory movement using indigenously developed software. Results: Studies were conducted with anthropomophic phantoms by simulating the respiratory motion on phantoms and recording the respective movements using the respiratory monitoring device. The results show good agreement between the simulated and measured movements. Further studies were conducted for 60 cancer patients with several types of cancers in the thoracic region. The respiratory movement cycles for each fraction of radiotherapy treatment were recorded and compared. Alarm indications are provided in the system to indicate when the patient breathing movement exceeds the threshold level. This will help the patient to maintain uniform breath hold during the radiotherapy treatment. Our preliminary clinical test results indicate that our device is highly reliable and able to maintain the uniform respiratory motion and breathe hold during the entire course of gated radiotherapy treatment. Conclusion: An indigenous respiratory monitoring device to guide the patient to have uniform breath hold device was fabricated. The alarm feature and the visual waveform indicator in the system guide the patient to have normal respiration. The signal from the device can be connected to the radiation unit in near future to carry out the gated radiotherapy treatment.

60 APPLIED LIFE SCIENCES↗

SU-E-T-103: Development and Implementation of Web Based Quality Control Software

Purpose: Historically many radiation medicine programs have maintained their Quality Control (QC) test results in paper records or Microsoft Excel worksheets. Both these approaches represent significant logistical challenges, and are not predisposed to data review and approval. It has been our group's aim to develop and implement web based software designed not just to record and store QC data in a centralized database, but to provide scheduling and data review tools to help manage a radiation therapy clinics Equipment Quality control program. Methods: The software was written in the Python programming language using the Django web framework. In order to promote collaboration and validation from other centres the code was made open source and is freely available to the public via an online source code repository. The code was written to provide a common user interface for data entry, formalize the review and approval process, and offer automated data trending and process control analysis of test results. Results: As of February 2014, our installation of QAtrack+ has 180 tests defined in its database and has collected ∼22 000 test results, all of which have been reviewed and approved by a physicist via QATrack+'s review tools. These results include records for quality control of Elekta accelerators, CT simulators, our brachytherapy programme, TomoTherapy and Cyberknife units. Currently at least 5 other centres are known to be running QAtrack+ clinically, forming the start of an international user community. Conclusion: QAtrack+ has proven to be an effective tool for collecting radiation therapy QC data, allowing for rapid review and trending of data for a wide variety of treatment units. As free and open source software, all source code, documentation and a bug tracker are available to the public at https://bitbucket.org/tohccmedphys/qatrackplus/.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-T-215: Interactive Dose Shaping: Proof of Concept Study for Six Prostate Patients

Purpose: To provide a proof of concept study for IMRT treatment planning through interactive dose shaping (IDS) by utilising the respective tools to create IMRT treatment plans for six prostate patients. Methods: The IDS planning paradigm aims to perform interactive local dose adaptations of an IMRT plan without compromising already established valuable dose features in real-time. Various IDS tools are available in our in-house treatment planning software Dynaplan and were utilised to create IMRT treatment plans for six patients with an adeno-carcinoma of the prostate. The sequenced IDS treatment plans were compared to conventionally optimised clinically approved plans (9 beams, co-planar). The starting point consisted of open fields. The IDS tools were utilised to sculpt dose out of the rectum and bladder. For each patient, several IDS plans were created, with different trade-offs between organ sparing and target coverage. The reference dose distributions were imported into Dynaplan. For each patient, the IDS treatment plan with a similar or better trade-off between target coverage and OAR sparing was selected for plan evaluation, guided by a physician. Pencil beam dose calculation was performed on a grid with a voxel size of 1.95×1.95×2.0 mm{sup 3}. D98%, D2%, mean dose and dose-volume indicators as specified by Quantec were calculated for plan evaluation. Results: It was possible to utilise the software prototype to generate treatment plans for prostate patient geometries in 15–45 minutes. Individual local dose adaptations could be performed in less than one second. The average differences compared to the reference plans were for the mean dose: 0.0 Gy (boost) and 1.2 Gy (CTV), for D98%: −1.1 Gy and for D2%: 1.1 Gy (both target volumes). The dose-volume quality indicators were well below the Quantec constraints. Conclusion: Real-time treatment planning utilising IDS is feasible and has the potential to be implemented clinically. Research at The Institute of Cancer Research is supported by Cancer Research UK under Programme C46/A10588.

60 APPLIED LIFE SCIENCES↗

SU-E-T-415: An Ionization Chamber Array with High Spatial Resolution for External Beam Radiotherapy

Purpose: To characterize an ionization chamber array technology with high spatial resolution and high charge collection efficiency for external beam radiotherapy. Methods: The prototype under test is a linear array of air vented ionization chambers developed by IBA Dosimetry, consisting of 80 pixels with 3.5mm spatial resolution and 4mm{sup 3} sensitive volume. The detector was characterized in a plastic phantom with {sup 60} Co radiation and MV X-rays from an ELEKTA Agility LINAC (with flattened and unflattened beam qualities). Bias voltage was varied in order to evaluate charge collection efficiency. A commercial array of ionization chambers (MatriXX Evolution, IBA Dosimetry) and an amorphous silicon flat panel in direct conversion configuration were used as references. Results: Repeatability (0.4%) and stability under continuous gamma irradiation (0.3%) are very good, in spite of low active volume and sensitivity (∼200pC/Gy). Charge collection efficiency is higher than 99% already at 150V with ∼2mGy dose per pulse, leading to a ±1.1% sensitivity change with dose per pulse in the range 0.09-2mGy (covering all flattened and unflattened applications). Measured dose profiles are in agreement with MatriXX for fields larger than 2×2cm{sup 2}, in which case the linear array offers a much better characterization of the penumbra region. Down to 1×1cm{sup 2}, measured profiles are in very good agreement with the flat panel. Conclusion: The array represents a valuable tool for the characterization of treatment fields in which high spatial resolution is required, together with the dosimetric performance of air vented ionization chambers. Such a technology would be particularly valuable in association with advanced treatment modalities such as rotational radiotherapy, stereotactic treatments (even with unflattened beam qualities) and proton therapy, due to the insensitivity of the chambers on dose per pulse. In the future, a two dimensional prototype based on this technology will be developed and tested. This research project has been supported by a Marie Curie Early Initial Training Network Fellowship of the European Community's Seventh Framework Programme under contract number (PITN-GA-2011-289198-.

07 ISOTOPE AND RADIATION SOURCES↗

TU-A-12A-06: Intra-Observer Variability in Delineation of Target Volumes in Breast Radiotherapy and Its Effect On Accuracy of Deformation Measurements

Purpose: In breast radiotherapy, the target volume may change during treatment and need adaptation of the treatment plan. This is possible for both tumour bed (TB) and whole breast (WB) target volumes. Delineation of the target (to detect changes) is also subject to uncertainty due to intra- and inter-observer variability. This work measured the uncertainty, due to intraobserver variability, in the quantification of tissue deformation. Methods: Datasets consisting of paired prone and supine CT scans of three patients were used. Significant deformation in target volumes is expected between prone and supine patient positions. The selected cases had 1) no seroma, 2) some seroma, and 3) large seroma. The TB and WB were outlined on each dataset three times by one clinician. Delineation variability was defined as the standard deviations of the distances between observer outlines. For each target volume and each case, tissue deformation between prone and supine delineations was quantified using the Dice similarity coefficient (DSC) and the average surface distance (ASD). The uncertainty in the tissue deformation (due to delineation variability) was quantified by measuring the ranges of DSC and ASD using all combinations of pairs of outlines (9 pairs). Results: For the TB, the range of delineation variability was 0.44-1.16 mm. The deformation, DSC and ASD, (and uncertainty in measurement) of the TB between prone and supine position of the cases were: 1) 0.21 (0.17-0.28) and 12.4 mm (11.8-13 mm); 2) 0.54 (0.51-0.57) and 3.3 mm (3.1-3.5 mm); 3) 0.62 (0.61-0.64) and 4.9 mm (4.6-5.2 mm). WB deformation measurements were subject to less uncertainty due to delineation variability than TB deformation measurements. Conclusion: For the first time, the uncertainty, due to observer variability, in the measurement of the deformation of breast target volumes was investigated. Deformations in these ranges would be difficult to detect. This work was supported in part by Cancer Research-UK under Programme Grant C46/A10588 and in part by the National Institute for Health Research (NIHR) through funding of the biomedical research imaging centre. P. Juneja is supported by the EPSRC Platform Grant EP/H046526/1.

60 APPLIED LIFE SCIENCES↗

WE-E-18A-02: Enhancement of Lung Tumor Visibility by Dual-Energy X-Ray Imaging in An Anthropomorphic Chest Phantom Study

Purpose: Intrafractional lung tumor motion during radiotherapy can be compensated for by tracking the tumor position using x-ray imaging and adapting the treatment in real-time. However, locating the tumor with an automated template-matching algorithm is often challenging if the tumor is obscured by ribs. This study investigates the feasibility of creating dual-energy (DE) images of the chest with increased tumor visibility on an Elekta XVI system. Methods: An anthropomorphic chest phantom was imaged at two different energies. Low-energy images were obtained at 80 kVp (0.8 mAs); high-energy images at 129 kVp (0.6 mAs, additional 1.26 mm tin filter). A Geant4 Monte-Carlo framework was developed allowing simulation of the x-ray tube, flat-panel detector and phantom in order to optimize the beam energies, filtration and the weighting factor used to subtract the individual images into a synthetic DE image. The weighting factor was selected to minimize the visibility of bones while maintaining a sufficient tumor visibility. We scored the bone visibility as the contrast of tumor (with bone) to tumor (without bone), and similarly of lung tissue (with bone) to lung tissue (without bone). Tumor visibility was quantified as the contrast between tumor and lung tissue (both without bone). Results: In the experimentally obtained DE image the bone visibility was reduced by 79.2% in tumor and by 96.8% in lung tissue while the overall tumor visibility only decreased by 69.5%. The Monte-Carlo simulation yielded similar results reducing the scores by 90.0%, 85.3% and only 71.9%, respectively. Conclusion: This work demonstrates the feasibility of DE imaging to enhance lung tumor detectability. In the future, we hope to further refine the Monte-Carlo simulation to more accurately predict the weighting factors which would aid real-time implementation. Furthermore, we plan to use the Monte-Carlo framework to simulate DE images of actual lung tumors. The authors would like to thank Paul-Scherrer-Institut and Centre Suisse d'Electronique et Microtechnique for lending us the anthropomorphic phantom. We acknowledge support from Elekta AB under a research agreement. Research at The Institute of Cancer Research is also supported by Cancer Research UK under Programme C46/A10588.

60 APPLIED LIFE SCIENCES↗