Search NASA⌕ Search

SEARCH · Search NASA

Results for “reference”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,765 records · Page 98

Using ordination and clustering techniques to assess multi-metric fish health response following a coal fly ash spill

The effect of coal ash exposure on fish health in freshwater communities is largely unknown. Given the large number of possible pathways of effects (e.g., toxicological effect of exposure to multiple metals, physical effects from ash exposure, and food web effects), measurement of only a few health metrics is not likely to give a complete picture. The authors measured a suite of 20 health metrics from 1100+ fish collected from 5 sites (3 affected and 2 reference) near a coal ash spill in east Tennessee over a 4.5-yr period. The metrics represented a wide range of physiological and energetic responses and were evaluated simultaneously using 2 multivariate techniques. Results from both hierarchical clustering and canonical discriminant analyses suggested that for most speciesXseason combinations, the suite of fish health indicators varied more among years than between spill and reference sites within a year. In a few cases, spill sites from early years in the investigation stood alone or clustered together separate from reference sites and later year spill sites. Outlier groups of fish with relatively unique health profiles were most often from spill sites, suggesting that some response to the ash exposure may have occurred. Results from the 2 multivariate methods suggest that any change in the health status of fish at the spill sites was small and appears to have diminished since the first 2 to 3 yr after the spill.

54 ENVIRONMENTAL SCIENCES↗

Reconstruction of Central European daily weather types back to 1763

Weather type classifications (WTCs) are a simple tool to analyse variations in weather patterns. Long series of WTCs could be used to address decadal changes in weather as a basis for studying changes in variability or extremes or for addressing contributions of sea-surface temperature or external forcings using climate models. However, there is no long series of daily objective weather types (WTs). A new method (Shortest Mahalanobis Distance, SMD) using daily European weather data is developed to reconstruct WTCs back in time. Here the SMD method is applied on the Cluster Analysis of Principal Components (CAP9) classification used by MeteoSwiss. The CAP9 daily WT time series (computed with ERA-40) is used as reference over the 1958–1998 period. Daily data (temperature, mean sea level pressure and pressure tendency) from 13 European stations covering the period 1763–2009 are used for the reconstruction. The reference CAP9 is reduced from nine to seven types so the new daily WTC is called CAP7. As an assessment, CAP7 is compared to the original classification CAP9 and to the same WTs computed with the Twentieth Century Reanalysis (20CR and 20CRv2c). Over the reference period up to 90% of all the daily WTs can be correctly reproduced in the new WTC compared to the original series, with higher reliability in winter than in summer. In addition, the reliability of the classification is increasing from 1763 onward. The annual occurrence of each type reveals some trends, mostly a decrease in the number of cyclonic days and an increase of cyclonic days.

54 ENVIRONMENTAL SCIENCES↗

Report on G4-Med, a Geant4 benchmarking system for medical physics applications developed by the Geant4 Medical Simulation Benchmarking Group

Geant4 is a Monte Carlo code extensively used in medical physics for a wide range of applications, such as dosimetry, micro- and nanodosimetry, imaging, radiation protection, and nuclear medicine. Geant4 is continuously evolving, so it is crucial to have a system that benchmarks this Monte Carlo code for medical physics against reference data and to perform regression testing. In this work, to respond to these needs, we developed G4-Med, a benchmarking and regression testing system of Geant4 for medical physics. G4-Med currently includes 18 tests. They range from the benchmarking of fundamental physics quantities to the testing of Monte Carlo simulation setups typical of medical physics applications. Both electromagnetic and hadronic physics processes and models within the prebuilt Geant4 physics lists are tested. The tests included in G4-Med are executed on the CERN computing infrastructure via the use of the geant-val web application, developed at CERN for Geant4 testing. The physical observables can be compared to reference data for benchmarking and to results of previous Geant4 versions for regression testing purposes. This paper describes the tests included in G4-Med and shows the results derived from the benchmarking of Geant4 10.5 against reference data.

60 APPLIED LIFE SCIENCES↗

Application of radiochromic gel dosimetry to commissioning of a megavoltage research linear accelerator for small–field animal irradiation studies

To develop and implement an efficient and accurate commissioning procedure for small-field static beam animal irradiation studies on an MV research linear accelerator (Linatron-M9) using radiochromic gel dosimetry. The research linear accelerator (Linatron-M9) is a 9 MV linac with a static fixed collimator opening of 5.08 cm diameter. Lead collimators were manually placed to create smaller fields of 2 × 2 cm 2 , 1 × 1 cm 2 , and 0.5 × 0.5 cm 2 . Relative dosimetry measurements were performed, including profiles, percent depth dose (PDD) curves, beam divergence, and relative output factors using various dosimetry tools, including a small volume ionization chamber (A14), GAFCHROMIC™ EBT3 film, and Clearview gel dosimeters. The gel dosimeter was used to provide a 3D volumetric reference of the irradiated fields. The Linatron profiles and relative output factors were extracted at a reference depth of 2 cm with the output factor measured relative to the 2 × 2 cm 2 reference field. Absolute dosimetry was performed using A14 ionization chamber measurements, which were verified using a national standards laboratory remote dosimetry service. Absolute dosimetry measurements were confirmed within 1.4% (k = 2, 95% confidence = 5%). The relative output factor of the small fields measured with films and gels agreed with a maximum relative percent error difference between the two methods of 1.1 % for the 1 × 1 cm 2 field and 4.3 % for the 0.5 × 0.5 cm 2 field. These relative errors were primarily due to the variability in the collimator positioning. The measured beam profiles demonstrated excellent agreement for beam size (measured as FWHM), within approximately 0.8 mm (or less). Film measurements were more accurate in the penumbra region due to the film’s finer resolution compared with the gel dosimeter. Following the van Dyk criteria, the PDD values of the film and gel measurements agree within 11% in the buildup region starting from 0.5 cm depth and within 2.6 % beyond maximum dose and into the fall-off region for depths up to 5 cm. The 2D beam profile isodose lines agree within 0.5 mm in all regions for the 0.5 × 0.5 cm 2 and the 1 × 1 cm 2 fields and within 1 mm for the larger field of 2 × 2 cm 2 . The 2D PDD curves agree within approximately 2% of the maximum in the typical therapy region (1–4 cm) for the 1 × 1 cm 2 and 2 × 2 cm 2 and within 5% for the 0.5 × 0.5 cm 2 field. This work provides a commissioning process to measure the beam characteristics of a fixed beam MV accelerator with detailed dosimetric evaluation for its implementation in megavoltage small animal irradiation studies. Radiochromic gel dosimeters are efficient small-field relative dosimetry tools providing 3D dose measurements allowing for full representation of dose, dosimeter misalignment corrections and high reproducibility with low inter-dosimeter variability. Altogether, radiochromic gels are valuable for fast, full relative dosimetry commissioning in comparison to films for application in high-energy small-field animal irradiation studies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of [ 11 C]TZ1964B and [ 18 F]MNI659 for PET imaging brain PDE10A in nonhuman primates

Abstract Phosphodiesterase 10A ( PDE 10A) inhibitors show therapeutic effects for diseases with striatal pathology. PET radiotracers have been developed to quantify in vivo PDE 10A levels and target engagement for therapeutic interventions. The aim of this study was to compare two potent and selective PDE 10A radiotracers, [ 11 C] TZ 1964B and [ 18 F] MNI 659 in the nonhuman primate ( NHP ) brain. Double scans in the same cynomolgus monkey on the same day were performed after injection of [ 11 C] TZ 1964B and [ 18 F] MNI 659. Specific uptake was determined in two ways: nondisplaceable binding potential ( BP ND ) was calculated using cerebellum as the reference region and the PDE ‐10A enriched striatum as the target region of interest ( ROI ); the area under the time–activity curve ( AUC ) for the striatum to cerebellum ratio was also calculated. High‐performance liquid chromatography ( HPLC ) analysis of solvent‐extracted NHP plasma identified the percentage of intact tracer versus radiolabeled metabolites samples post injection of each radiotracer. Both radiotracers showed high specific accumulation in NHP striatum. [ 11 C] TZ 1964B has higher striatal retention and lower specific striatal uptake than [ 18 F] MNI 659. The BP ND estimates of [ 11 C] TZ 1964B were 3.72 by Logan Reference model (Logan REF ) and 4.39 by simplified reference tissue model ( SRTM ); the BP ND estimates for [ 18 F] MNI 659 were 5.08 (Logan REF ) and 5.33 ( SRTM ). AUC ratios were 5.87 for [ 11 C] TZ 1964B and 7.60 for [ 18 F] MNI 659. Based on BP ND values in NHP striatum, coefficients of variation were ~10% for [ 11 C] TZ 1964B and ~30% for [ 18 F] MNI 659. Moreover, the metabolism study showed the percentage of parent compounds were ~70% for [ 11 C] TZ 1964B and ~50% for [ 18 F] MNI 659 60 min post injection. These data indicate that either [ 11 C] TZ 1964B or [ 18 F] MNI 659 could serve as suitable PDE 10A PET radiotracers with distinguishing features for particular clinical application.

59 BASIC BIOLOGICAL SCIENCES↗

Carbonate clumped isotope analysis (Δ 47 ) of 21 carbonate standards determined via gas‐source isotope‐ratio mass spectrometry on four instrumental configurations using carbonate‐based standardization and multiyear data sets

Rationale Clumped isotope geochemistry examines the pairing or clumping of heavy isotopes in molecules and provides information about the thermodynamic and kinetic controls on their formation. The first clumped isotope measurements of carbonate minerals were first published 15 years ago, and since then, interlaboratory offsets have been observed, and laboratory and community practices for measurement, data analysis, and instrumentation have evolved. Here we briefly review historical and recent developments for measurements, share Tripati Lab practices for four different instrument configurations, test a recently published proposal for carbonate‐based standardization on multiple instruments using multi‐year data sets, and report values for 21 different carbonate standards that allow for recalculations of previously published data sets. Methods We examine data from 4628 standard measurements on Thermo MAT 253 and Nu Perspective IS mass spectrometers, using a common acid bath (90°C) and small‐sample (70°C) individual reaction vessels. Each configuration was investigated by treating some standards as anchors (working standards) and the remainder as unknowns (consistency standards). Results We show that different acid digestion systems and mass spectrometer models yield indistinguishable results when instrument drift is well characterized. For linearity correction, mixed gas‐and‐carbonate standardization or carbonate‐only standardization yields similar results. No difference is observed in the use of three or eight working standards for the construction of transfer functions. Conclusions We show that all configurations yield similar results if instrument drift is robustly characterized and validate a recent proposal for carbonate‐based standardization using large multiyear data sets. Δ 47 values are reported for 21 carbonate standards on both the absolute reference frame (ARF; also refered to as the Carbon Dioxide Equilibrated Scale or CDES) and the new InterCarb‐Carbon Dioxide Equilibrium Scale (I‐CDES) reference frame, facilitating intercomparison of data from a diversity of labs and instrument configurations and restandardization of a broad range of sample sets between 2006, when the first carbonate measurements were published, and the present.

58 GEOSCIENCES↗

OpenSHMEM-UCX: Evaluation of UCX for Implementing OpenSHMEM Programming Model, In: OpenSHMEM 2016: OpenSHMEM and Related Technologies. Enhancing OpenSHMEM for Hybrid Environments

The OpenSHMEM reference implementation was developed towards the goal of developing an open source and high-performing OpenSHMEM implementation. To achieve portability and performance across various networks, the OpenSHMEM reference implementation uses GASNet and UCCS for network operations. Recently, new network layers have emerged with the promise of providing high-performance, scalability, and portability for HPC applications. In this paper, we implement the OpenSHMEM reference implementation to use the UCX framework for network operations. Then, we evaluate its performance and scalability on Cray XK systems to understand UCX’s suitability for developing the OpenSHMEM programming model. Further, we develop a benchmark called SHOMS for evaluating the OpenSHMEM implementation. Our experimental results show that OpenSHMEM-UCX outperforms the vendor supplied OpenSHMEM implementation in most cases on the Cray XK system by up to 40% with respect to message rate and up to 70% for the execution of application kernels.

Computer Science↗

First measurements of N -subjettiness in central Pb-Pb collisions at $\sqrt{s{NN}}$= 2.76 TeV

The ALICE Collaboration reports the first fully-corrected measurements of the N-subjettiness observable for track-based jets in heavy-ion collisions. This study is performed using data recorded in pp and Pb-Pb collisions at centre-of-mass energies of $\sqrt{s}$= 7 TeV and $\sqrt{s{NN}}$ = 2.76 TeV, respectively. In particular the ratio of 2-subjettiness to 1-subjettiness, τ 2 /τ 1 , which is sensitive to the rate of two-pronged jet substructure, is presented. Energy loss of jets traversing the strongly interacting medium in heavy-ion collisions is expected to change the rate of two-pronged substructure relative to vacuum. The results are presented for jets with a resolution parameter of R = 0.4 and charged jet transverse momentum of 40 ≤ pτ, jet ≤ 60 GeV/c, which constitute a larger jet resolution and lower jet transverse momentum interval than previous measurements in heavy-ion collisions. This has been achieved by utilising a semi-inclusive hadron-jet coincidence technique to suppress the larger jet combinatorial background in this kinematic region. No significant modification of the τ 2 /τ 1 observable for track-based jets in Pb-Pb collisions is observed relative to vacuum PYTHIA6 and PYTHIA8 references at the same collision energy. The measurements of τ 2 /τ 1 , together with the splitting aperture angle ΔR, are also performed in pp collisions at $\sqrt{s}$ = 7 TeV for inclusive jets. These results are compared with PYTHIA calculations at $\sqrt{s}$ = 7 TeV, in order to validate the model as a vacuum reference for the Pb-Pb centre-of-mass energy. The PYTHIA references for τ 2 /τ 1 are shifted to larger values compared to the measurement in pp collisions. This hints at a reduction in the rate of two-pronged jets in Pb-Pb collisions compared to pp collisions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Phantom Study Investigating the Accuracy of Manual and Automatic Image Fusion with the GE Logiq E9: Implications for use in Percutaneous Liver Interventions

PurposeTo determine the accuracy of automatic and manual co-registration methods for image fusion of three-dimensional computed tomography (CT) with real-time ultrasonography (US) for image-guided liver interventions.Materials and MethodsCT images of a skills phantom with liver lesions were acquired and co-registered to US using GE Logiq E9 navigation software. Manual co-registration was compared to automatic and semiautomatic co-registration using an active tracker. Also, manual point registration was compared to plane registration with and without an additional translation point. Finally, comparison was made between manual and automatic selection of reference points. In each experiment, accuracy of the co-registration method was determined by measurement of the residual displacement in phantom lesions by two independent observers.ResultsMean displacements for a superficial and deep liver lesion were comparable after manual and semiautomatic co-registration: 2.4 and 2.0 mm versus 2.0 and 2.5 mm, respectively. Both methods were significantly better than automatic co-registration: 5.9 and 5.2 mm residual displacement (p < 0.001; p < 0.01). The accuracy of manual point registration was higher than that of plane registration, the latter being heavily dependent on accurate matching of axial CT and US images by the operator. Automatic reference point selection resulted in significantly lower registration accuracy compared to manual point selection despite lower root-mean-square deviation (RMSD) values.ConclusionThe accuracy of manual and semiautomatic co-registration is better than that of automatic co-registration. For manual co-registration using a plane, choosing the correct plane orientation is an essential first step in the registration process. Automatic reference point selection based on RMSD values is error-prone.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Efficiency Improvement in a Busy Radiology Practice: Determination of Musculoskeletal Magnetic Resonance Imaging Protocol Using Deep-Learning Convolutional Neural Networks

The purposes of this study are to evaluate the feasibility of protocol determination with a convolutional neural networks (CNN) classifier based on short-text classification and to evaluate the agreements by comparing protocols determined by CNN with those determined by musculoskeletal radiologists. Following institutional review board approval, the database of a hospital information system (HIS) was queried for lists of MRI examinations, referring department, patient age, and patient gender. These were exported to a local workstation for analyses: 5258 and 1018 consecutive musculoskeletal MRI examinations were used for the training and test datasets, respectively. The subjects for pre-processing were routine or tumor protocols and the contents were word combinations of the referring department, region, contrast media (or not), gender, and age. The CNN Embedded vector classifier was used with Word2Vec Google news vectors. The test set was tested with each classification model and results were output as routine or tumor protocols. The CNN determinations were evaluated using the receiver operating characteristic (ROC) curves. The accuracies were evaluated by a radiologist-confirmed protocol as the reference protocols. The optimal cut-off values for protocol determination between routine protocols and tumor protocols was 0.5067 with a sensitivity of 92.10%, a specificity of 95.76%, and an area under curve (AUC) of 0.977. The overall accuracy was 94.2% for the ConvNet model. All MRI protocols were correct in the pelvic bone, upper arm, wrist, and lower leg MRIs. Deep-learning-based convolutional neural networks were clinically utilized to determine musculoskeletal MRI protocols. CNN-based text learning and applications could be extended to other radiologic tasks besides image interpretations, improving the work performance of the radiologist.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Uncertainties in climate stabilization

We explore the atmospheric composition, temperature and sea level implications of new reference and cost-optimized stabilization emissions scenarios produced using three different Integrated Assessment (IA) models for U.S. Climate Change Science Program (CCSP) Synthesis and Assessment Product 2.1a. We also consider an extension of one of these sets of scenarios out to 2300. Stabilization is defined in terms of radiative forcing targets for the sum of gases potentially controlled under the Kyoto Protocol. For the most stringent stabilization case (“Level 1” with CO2 concentration stabilizing at about 450 ppm), peak CO2 emissions occur close to today, implying a need for immediate CO2 emissions abatement if we wish to stabilize at this level. In the extended reference case, CO2 stabilizes at 1000 ppm in 2200 – but even to achieve this target requires large and rapid CO2 emissions reductions over the 22nd century. Future temperature changes for the Level 1 stabilization case show considerable uncertainty even when a common set of climate model parameters is used (a result of different assumptions for non-Kyoto gases). Uncertainties are about a factor of three when climate sensitivity uncertainties are accounted for. We estimate the probability that warming from pre-industrial times will be less than 2oC to be about 50%. For one of the IA models, warming in the Level 1 case is greater out to 2050 than in the reference case, due to the effect of decreasing SO2 emissions that occur as a side effect of the policy-driven reduction in CO2 emissions. Sea level rise uncertainties for the Level 1 case are very large, with increases ranging from 12 to 100 cm over 2000 to 2300.

54 ENVIRONMENTAL SCIENCES↗

Cross-scale intercomparison of climate change impacts simulated by regional and global hydrological models in eleven large river basins

Ideally, the results from models operating at different scales should agree in trend direction and magnitude of impacts under climate change. However, this implies that the sensitivity of impact models designed for either scale to climate variability and change is comparable. In this study, we compare hydrological changes simulated by 9 global and 9 regional hydrological models (HM) for 11 large river basins in all continents under reference and scenario conditions. The foci are on model validation runs, sensitivity of annual discharge to climate variability in the reference period, and sensitivity of the long-term average monthly seasonal dynamics to climate change. One major result is that the global models, mostly not calibrated against observations, often show a considerable bias in mean monthly discharge, whereas regional models show a much better reproduction of reference conditions. However, the sensitivity of two HM ensembles to climate variability is in general similar. The simulated climate change impacts in terms of long-term average monthly dynamics evaluated for HM ensemble medians and spreads show that the medians are to a certain extent comparable in some cases with distinct differences in others, and the spreads related to global models are mostly notably larger. Summarizing, this implies that global HMs are useful tools when looking at large-scale impacts of climate change and variability, but whenever impacts for a specific river basin or region are of interest, e.g. for complex water management applications, the regional-scale models validated against observed discharge should be used.

54 ENVIRONMENTAL SCIENCES↗

The role of methane in future climate strategies: mitigation potentials and climate impacts

This study examines model-specific assumptions and projections of methane (CH 4 ) emissions in deep mitigation scenarios generated by integrated assessment models (IAMs). For this, scenarios of nine models are compared in terms of sectoral and regional CH 4 emission reduction strategies, as well as resulting climate impacts. The models’ projected reduction potentials are compared to sector and technology-specific reduction potentials found in literature. Significant cost-effective and non-climate policy related reductions are projected in the reference case (10–36% compared to a “frozen emission factor” scenario in 2100). Still, compared to 2010, CH 4 emissions are expected to rise steadily by 9–72% (up to 412 to 654 Mt CH 4 /year). Ambitious CO 2 reduction measures could by themselves lead to a reduction of CH 4 emissions due to a reduction of fossil fuels (22–48% compared to the reference case in 2100). However, direct CH 4 mitigation is crucial and more effective in bringing down CH 4 (50–74% compared to the reference case). Given the limited reduction potential, agriculture CH 4 emissions are projected to constitute an increasingly larger share of total anthropogenic CH 4 emissions in mitigation scenarios. Enteric fermentation in ruminants is in that respect by far the largest mitigation bottleneck later in the century with a projected 40–78% of total remaining CH 4 emissions in 2100 in a strong (2 °C) climate policy case.

54 ENVIRONMENTAL SCIENCES↗

Spectral Analysis of 3-(Adamantan-1-yl)-4-Ethyl-1-[(4-Phenylpiperazin-1-yl) Methyl]-1H-1,2,4-Triazole-5(4H)-Thione

Vibrational IR (3200–650 cm{sup –1}) and Raman spectra (3200–150 cm{sup –1}) of adamantane-containing 3-(adamantan-1-yl)-4-ethyl-1-[(4-phenylpiperazin-1-yl)methyl]-1H-1,2,4-triazole-5(4H)-thione, which is promising for drug design, were examined. The UV/Vis spectrum (450–200 nm) of the compound in EtOH was measured. Full geometry optimization using density functional theory (DFT) in the B3LYP/cc-pVDZ approximation allowed the equilibrium configuration of the molecule to be determined and IR and Raman spectra to be calculated. Based on these, the experimental vibrational IR and Raman spectra were interpreted and the biological activity indices were predicted. The UV/Vis spectrum of the title compound was simulated at the time-dependent DFT/CAM-B3LYP/cc-pVDZ level with and without solvent effects and at the ab initio multi-reference perturbation theory XMCQDPT2 level. The UV/Vis spectrum that was simulated using the multi-reference XMCQDPT2 approximation agreed very successfully with the experimental data, in contrast to the single-reference DFT method. This was probably a consequence of intramolecular charge transfer.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Elaboration and Properties of Innovative Biobased PUIR Foams from Microalgae

Foams were elaborated from biobased epoxides and polyols derived from highly unsaturated oil of microalgae (schizochytrium sp.). The same types of chemicals were also synthesized from rapeseed oil, and used as references. Triglycerides derivatives were characterized by IR, titration, NMR and SEC analysis. Epoxidation reaction led to fully epoxidized oils, from both bioresources. These epoxidized oils were transformed in polyols via epoxide ring opening reaction with methanol. A preliminary study was focused on the elaboration of urethane-modified isocyanurate (PUIR) foams to evaluate the reactivity and effect of the previously synthesized derivatives (epoxides and polyols) with isocyanates. These derivatives were used to partially substitute oxypropylated glycerol (OPG), a conventional reference polyol. All elaborated foams were close to the PUIR reference (only based on OPG), in terms of kinetics and morphology. PUIR thermal stability was improved, using directly epoxides derivatives.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Investigation of the Microstructural Changes and Hardness Variations of Sub-Zero Treated Cr-V Ledeburitic Tool Steel Due to the Tempering Treatment

The microstructure and tempering response of Cr-V ledeburitic steel Vanadis 6 subjected to sub-zero treatment at − 196 °C for 4 h have been examined with reference to the same steel after conventional heat treatment. The obtained experimental results infer that sub-zero treatment significantly reduces the retained austenite amount, makes an overall refinement of microstructure, and induces a significant increase in the number and population density of small globular carbides with a size 100-500 nm. At low tempering temperatures, the transient M{sub 3}C-carbides precipitated, whereas their number was enhanced by sub-zero treatment. The presence of chromium-based M{sub 7}C{sub 3} precipitates was evidenced after tempering at the temperature of normal secondary hardening; this phase was detected along with the M{sub 3}C. Tempering above 470 °C converts almost all the retained austenite in conventionally quenched specimens while the transformation of retained austenite is rather accelerated in sub-zero treated material. As a result of tempering, a decrease in the population density of small globular carbides was recorded; however, the number of these particles retained much higher in sub-zero treated steel. Elevated hardness of sub-zero treated steel can be referred to more completed martensitic transformation and enhanced number of small globular carbides; this state is retained up to a tempering temperature of around 500 °C in certain extent. Correspondingly, lower as-tempered hardness of sub-zero treated steel tempered above 500 °C is referred to much lower contribution of the transformation of retained austenite, and to an expectedly lower amount of precipitated alloy carbides.

36 MATERIALS SCIENCE↗

Assessing time-of-flight signal-to-noise ratio gains within the myocardium and subsequent reductions in administered activity in cardiac PET studies

Background: Time-of-flight (TOF) is known to increase signal-to-noise ratio (SNR) and facilitate reductions in administered activity. Established measures of SNR gain are derived from areas of uniform uptake, which is not applicable to the heterogeneous uptake in cardiac PET images using fluoro-deoxyglucose (FDG). This study aimed to develop a technique to quantify SNR gains within the myocardium due to TOF. Methods: Reference TOF SNR gains were measured in 88 FDG oncology patients. Phantom data were used to translate reference SNR gains and validate a method of quantifying SNR gains within the myocardium from parametric images produced from multiple replicate images. This technique was applied to 13 FDG cardiac viability patients. Results: Reference TOF SNR gains of +23% ± 8.5% were measured in oncology patients. Measurements of SNR gain from the phantom data were in agreement and showed the parametric image technique to be sufficiently robust. SNR gains within the myocardium in the viability patients were +21% ± 2.8%. Conclusion: A method to quantify SNR gains from TOF within the myocardium has been developed and evaluated. SNR gains within the myocardium are comparable to those observed by established methods. This allows guidance for protocol optimization for TOF systems in cardiac PET.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Fungal diversity notes 253–366: taxonomic and phylogenetic contributions to fungal taxa

Notes on 113 fungal taxa are compiled, including 11 new genera, 89 new species, one new subspecies, three new combinations and seven reference specimens. A wide geographic and taxonomic range of fungal taxa are detailed. In the Ascomycota the new genera Angustospora (Testudinaceae), Camporesia (Xylariaceae), Clematidis, Crassiparies (Pleosporales genera incertae sedis), Farasanispora, Longiostiolum (Pleosporales genera incertae sedis), Multilocularia (Parabambusicolaceae), Neophaeocryptopus (Dothideaceae), Parameliola (Pleosporales genera incertae sedis), and Towyspora (Lentitheciaceae) are introduced. Newly introduced species are Angustospora nilensis, Aniptodera aquibella, Annulohypoxylon albidiscum, Astrocystis thailandica, Camporesia sambuci, Clematidis italica, Colletotrichum menispermi, C. quinquefoliae, Comoclathris pimpinellae, Crassiparies quadrisporus, Cytospora salicicola, Diatrype thailandica, Dothiorella rhamni, Durotheca macrostroma, Farasanispora avicenniae, Halorosellinia rhizophorae, Humicola koreana, Hypoxylon lilloi, Kirschsteiniothelia tectonae, Lindgomyces okinawaensis, Longiostiolum tectonae, Lophiostoma pseudoarmatisporum, Moelleriella phukhiaoensis, M. pongdueatensis, Mucoharknessia anthoxanthi, Multilocularia bambusae, Multiseptospora thysanolaenae, Neophaeocryptopus cytisi, Ocellularia arachchigei, O. ratnapurensis, Ochronectria thailandica, Ophiocordyceps karstii, Parameliola acaciae, P. dimocarpi, Parastagonospora cumpignensis, Pseudodidymosphaeria phlei, Polyplosphaeria thailandica, Pseudolachnella brevifusiformis, Psiloglonium macrosporum, Rhabdodiscus albodenticulatus, Rosellinia chiangmaiensis, Saccothecium rubi, Seimatosporium pseudocornii, S. pseudorosae, Sigarispora ononidis and Towyspora aestuari. New combinations are provided for Eutiarosporella dactylidis (sexual morph described and illustrated) and Pseudocamarosporium pini. Descriptions, illustrations and / or reference specimens are designated for Aposphaeria corallinolutea, Cryptovalsa ampelina, Dothiorella vidmadera, Ophiocordyceps formosana, Petrakia echinata, Phragmoporthe conformis and Pseudocamarosporium pini. The new species of Basidiomycota are Agaricus coccyginus, A. luteofibrillosus, Amanita atrobrunnea, A. digitosa, A. gleocystidiosa, A. pyriformis, A. strobilipes, Bondarzewia tibetica, Cortinarius albosericeus, C. badioflavidus, C. dentigratus, C. duboisensis, C. fragrantissimus, C. roseobasilis, C. vinaceobrunneus, C. vinaceogrisescens, C. wahkiacus, Cyanoboletus hymenoglutinosus, Fomitiporia atlantica, F. subtilissima, Ganoderma wuzhishanensis, Inonotus shoreicola, Lactifluus armeniacus, L. ramipilosus, Leccinum indoaurantiacum, Musumecia alpina, M. sardoa, Russula amethystina subp. tengii and R. wangii are introduced. Descriptions, illustrations, notes and / or reference specimens are designated for Clarkeinda trachodes, Dentocorticium ussuricum, Galzinia longibasidia, Lentinus stuppeus and Leptocorticium tenellum. The other new genera, species new combinations are Anaeromyces robustus, Neocallimastix californiae and Piromyces finnis from Neocallimastigomycota, Phytophthora estuarina, P. rhizophorae, Salispina, S. intermedia, S. lobata and S. spinosa from Oomycota, and Absidia stercoraria, Gongronella orasabula, Mortierella calciphila, Mucor caatinguensis, M. koreanus, M. merdicola and Rhizopus koreanus in Zygomycota.

59 BASIC BIOLOGICAL SCIENCES↗