Search NASA⌕ Search

SEARCH · Search NASA

Results for “sampling methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,765 records · Page 98

Submillimeter Measurements of Photolysis Products in Interstellar Ice Analogs: A New Experimental Technique

Over 150 molecular species have been confirmed in space, primarily by their rotational spectra at millimeter/submillimeter wavelengths, which yield an unambiguous identification. Many of the known interstellar organic molecules cannot be explained by gas-phase chemistry. It is now presumed that they are produced by surface reactions of the simple ices and/or grains observed and released into the gas phase by sublimation, sputtering, etc. Additionally, the chemical complexity found in meteorites and samples returned from comets far surpasses that of the remote detections for the interstellar medium (ISM), comets, and planetary atmospheres. Laboratory simulations of interstellar/cometary ices have found, from the analysis of the remnant residue of the warmed laboratory sample, that such molecules are readily formed; however, it has yet to be determined if they are formed during the warm phase or within the ice during processing. Most analysis of the ice during processing reveals molecular changes, though the exact quantities and species formed are highly uncertain with current techniques due to overwhelming features of simple ices. Remote sensing with high resolution spectroscopy is currently the only method to detect trace species in the ISM and the primary method for comets and icy bodies in the Solar System due to limitations of sample return. We have recently designed an experiment to simulate interstellar/cometary/planetary ices and detect trace species employing the same techniques used for remote observations. Preliminary results will be presented.

Milam, Stefanie N.↗

Contactless method of measuring resistivity

A method is described for measuring the conductivity of materials without having to make electrical contact with the material. Currents which are magnetically induced in the conducting sample are measured by means of the magnetic fields they produce. Although induction techniques have been used in the past for this type of measurement, the configuration presented here makes it possible to perform absolute measurements of resistivity over a wide range of values for relatively small samples. The theory of the technique, the results of measurements made with it, and a comparison of the technique with other methods are presented.

Crowley, J. D.↗

TEMPUS: First results

The electromagnetic levitation facility, TEMPUS, developed by Dornier is designed to operate under microgravity conditions. Compared to terrestrial levitation, microgravity offers the possibility to melt and undercool in ultra high vacuum, thereby, providing an ultra clean environment. The technical concept of the TEMPUS facility was tested on two KC 135 flights and in the Texus 22 mission. Preparative investigations concerning the coil system and the heating and positioning efficiencies were carried out in the TEMPUS laboratory version. Furthermore, temperature-time profiles were determined under various boundary conditions. As a consequence of processing liquid metals under UHV, correct temperature measurement arises as the most critical problem. Experiences with experiments in the TEMPUS laboratory module show that due to the evaporation losses of the sample, the transmission of the CaF2 shielding windows changes drastically during the processing time. The investigation of the effect of contamination on pyrometry and the development of alternative evaporation shielding methods were initiated. During the second KC 135 flight, it was possible to heat up and melt an FeNi sample under He atmosphere. Oscillations of the molten sample, which were excited by switching out the magnetic heating field, could be detected and afterwards analyzed. From the frequency of these oscillations the surface tension of the sample material could be derived. The measurement of the surface tension and viscosity of an undercooled metal is proposed for TEMPUS on IML-2. This document is presented in view graph form.

Neuhaus, P.↗

Photographic quantification of water quality in mixing zones

A method was developed to quantitatively delineate waste concentrations throughout waste effluent mixing zones on the basis of densitometric measurements extracted from aerial photography. A mixing zone is the extent of a receiving water body ultilized to dilute a waste discharge to a concentration characteristic of a totally mixed condition. Simultaneously-acquired color infrared photography and suspended solids water samples were used to quantitatively delineate the mixing zone resulting from the discharge of a paper mill effluent. Digital scanning microdensitometer data was used to estimate and delineate suspended solids concentrations on the basis of a semi-empirical model. Photographic photometry, when predicated on a limited amount of ground sampling, can measure and delineate mixing zone waste distributions in more detail then conventional surface measuring techniques. The method has direct application to: (1) the establishment of definite and rational water quality guidelines; (2) the development of sampling and surveillance programs for use by governmental and private agencies; and (3) the development of design and location criteria for industrial and municipal waste effluent outfalls.

Lillesand, T. M.↗

International Space Station Air Quality Assessed According to Toxicologically-Grouped Compounds

Scores of compounds are found in the International Space Station (ISS) atmospheric samples that are returned to the Johnson Space Center Toxicology Laboratory for analysis. Spacecraft Maximum Allowable Concentrations (SMACs) are set with the view that each compound is present as if there were no other compounds present. In order to apply SMACs to the interpretation of the analytical data, the toxicologist must employ some method of combining the potential effects of the aggregate of compounds found in the atmospheric samples. The simplest approach is to assume that each quantifiable compound has the potential for some effect in proportion to the applicable SMAC, and then add all the proportions. This simple paradigm disregards the fact that most compounds have potential to adversely affect only a few physiological systems, and their effects would be independent rather than additive. An improved approach to dealing with exposure to mixtures is to add the proportions only for compounds that adversely affect the same physiological system. For example, toxicants that cause respiratory irritation are separated from those that cause neurotoxicity or cardio-toxicity. Herein we analyze ISS air quality data according to toxicological groups with a view that this could be used for understanding any crew symptoms occurring at the time of the sample. In addition, this approach could be useful in post-flight longitudinal surveys where the flight surgeon may need to identify post-flight, follow-up medical studies because of on-orbit exposures that target specific physiological systems.

James, John T.↗

International Space Station Air Quality Assessed According to Toxicologically-Grouped Compounds

Scores of compounds are found in the International Space Station (ISS) atmospheric samples that are returned to the Johnson Space Center Toxicology Laboratory for analysis. Spacecraft Maximum Allowable Concentrations (SMACs) are set with the view that each compound is present as if there were no other compounds present. In order to apply SMACs to the interpretation of the analytical data, the toxicologist must employ some method of combining the potential effects of the aggregate of compounds found in the atmospheric samples. The simplest approach is to assume that each quantifiable compound has the potential for some effect in proportion to the applicable SMAC, and then add all the proportions. This simple paradigm disregards the fact that most compounds have potential to adversely affect only a few physiological systems, and their effects would be independent rather than additive. An improved approach to dealing with exposure to mixtures is to add the proportions only for compounds that adversely affect the same physiological system. For example, toxicants that cause respiratory irritation are separated from those that cause neurotoxicity or cardio-toxicity. Herein we analyze ISS air quality data according to toxicological groups with a view that this could be used for understanding any crew symptoms occurring at the time of the sample acquisition. In addition, this approach could be useful in post-flight longitudinal surveys where the flight surgeon may need to identify post-flight, follow-up medical studies because of on-orbit exposures that target specific physiological systems.

James, John T.↗

Nondestructive Evaluation (NDE) for Characterizing Oxidation Damage in Cracked Reinforced Carbon-Carbon

In this study, coated reinforced carbon-carbon (RCC) samples of similar structure and composition as that from the NASA space shuttle orbiter's thermal protection system were fabricated with slots in their coating simulating craze cracks. These specimens were used to study oxidation damage detection and characterization using nondestructive evaluation (NDE) methods. These specimens were heat treated in air at 1143 C and 1200 C to create cavities in the carbon substrate underneath the coating as oxygen reacted with the carbon and resulted in its consumption. The cavities varied in diameter from approximately 1 to 3mm. Single-sided NDE methods were used because they might be practical for on-wing inspection, while X-ray micro-computed tomography (CT) was used to measure cavity sizes in order to validate oxidation models under development for carbon-carbon materials. An RCC sample having a naturally cracked coating and subsequent oxidation damage was also studied with X-ray micro-CT. This effort is a follow-on study to one that characterized NDE methods for assessing oxidation damage in an RCC sample with drilled holes in the coating.

Roth, Don J.↗

Quantifying the Uncertainties in an Ensemble of Decadal Climate Predictions

Meaningful climate predictions should be accompanied by the corresponding uncertainty range. Common methods for estimating the uncertainty range are based on the spread of ensemble predictions. However, a simulation ensemble is not necessarily a proper sample of the real distribution of the climate, and therefore, the ensemble spread cannot be interpreted as the actual uncertainty. We propose a new method that links between the ensemble spread and the uncertainty without relying on any assumptions regarding the distribution of the ensemble predictions. The method is tested using CMIP5 1981-2010 decadal predictions and is shown to outperform other common methods.

Strobach, Ehud↗

Rapid System to Quantitatively Characterize the Airborne Microbial Community

Bioaerosols have been linked to a wide range of different allergies and respiratory illnesses. Currently, microorganism culture is the most commonly used method for exposure assessment. Such culture techniques, however, generally fail to detect between 90-99% of the actual viable biomass. Consequently, an unbiased technique for detecting airborne microorganisms is essential. In this Phase II proposal, a portable air sampling device his been developed for the collection of airborne microbial biomass from indoor (and outdoor) environments. Methods were evaluated for extracting and identifying lipids that provide information on indoor air microbial biomass, and automation of these procedures was investigated. Also, techniques to automate the extraction of DNA were explored.

Macnaughton, Sarah J.↗

Technique for Performing Dielectric Property Measurements at Microwave Frequencies

A paper discusses the need to perform accurate dielectric property measurements on larger sized samples, particularly liquids at microwave frequencies. These types of measurements cannot be obtained using conventional cavity perturbation methods, particularly for liquids or powdered or granulated solids that require a surrounding container. To solve this problem, a model has been developed for the resonant frequency and quality factor of a cylindrical microwave cavity containing concentric cylindrical samples. This model can then be inverted to obtain the real and imaginary dielectric constants of the material of interest. This approach is based on using exact solutions to Maxwell s equations for the resonant properties of a cylindrical microwave cavity and also using the effective electrical conductivity of the cavity walls that is estimated from the measured empty cavity quality factor. This new approach calculates the complex resonant frequency and associated electromagnetic fields for a cylindrical microwave cavity with lossy walls that is loaded with concentric, axially aligned, lossy dielectric cylindrical samples. In this approach, the calculated complex resonant frequency, consisting of real and imaginary parts, is related to the experimentally measured quantities. Because this approach uses Maxwell's equations to determine the perturbed electromagnetic fields in the cavity with the material(s) inserted, one can calculate the expected wall losses using the fields for the loaded cavity rather than just depending on the value of the fields obtained from the empty cavity quality factor. These additional calculations provide a more accurate determination of the complex dielectric constant of the material being studied. The improved approach will be particularly important when working with larger samples or samples with larger dielectric constants that will further perturb the cavity electromagnetic fields. Also, this approach enables the ability to have a larger sample of interest, such as a liquid or powdered or granulated solid, inside a cylindrical container.

Barmatz, Martin B.↗

Nondestructive Evaluation (NDE) for Characterizing Oxidation Damage in Cracked Reinforced Carbon-Carbon (RCC)

In this study, coated reinforced carbon-carbon (RCC) samples of similar structure and composition as that from the NASA space shuttle orbiter's thermal protection system were fabricated with slots in their coating simulating craze cracks. These specimens were used to study oxidation damage detection and characterization using nondestructive evaluation (NDE) methods. These specimens were heat treated in air at 1143 and 1200 C to create cavities in the carbon substrate underneath the coating as oxygen reacted with the carbon and resulted in its consumption. The cavities varied in diameter from approximately 1 to 3 mm. Single-sided NDE methods were used since they might be practical for on-wing inspection, while x-ray micro-computed tomography (CT) was used to measure cavity sizes in order to validate oxidation models under development for carbon-carbon materials. An RCC sample having a naturally-cracked coating and subsequent oxidation damage was also studied with x-ray micro-CT. This effort is a follow-on study to one that characterized NDE methods for assessing oxidation damage in an RCC sample with drilled holes in the coating.

Roth, Don J.↗

Rotating Pip Detection and Stall Warning in High-Speed Compressors Using Structure Function

A statistic for both rotating pip and incipient stall detection, called Structure Function is introduced for use in high speed research compressor environments. Experimental studies on stall inception processes have long observed two types of pre-stall compressor activity. Presently there exist methods for indicating modal stall precursive events in the compressor. This is a first application of a new method to detect rotating pip activity prior to stall in research compressors. The algorithm requires a very short sample of data to distinguish pip activity prior to stall, and thus may be used in a real time application. Additionally, this Structure Function algorithm is also used as a single sensor stall warning method under a variety of operating conditions, including clean inlet conditions, radially and circumferentially distorted inlet conditions, and in examples of steady air injection along the casing, and controlled air injection conditions. Structure Function provides a potential advantage over linear spectral techniques and wavelet algorithms for stall detection due to the simplicity of the algorithm and because it does not rely on a priori knowledge of frequency content.

Bright, Michelle M.↗

Quantitative Method of Measuring Metastatic Activity

The metastatic potential of tumors can be evaluated by the quantitative detection of urokinase and DNA. The cell sample selected for examination is analyzed for the presence of high levels of urokinase and abnormal DNA using analytical flow cytometry and digital image analysis. Other factors such as membrane associated uroldnase, increased DNA synthesis rates and certain receptors can be used in the method for detection of potentially invasive tumors.

Morrison, Dennis R.↗

Quantitation of Trace Water in ISS Atmosphere Samples Recovered from CO2-Removal Systems

As crewed spaceflight continues to push the limits of exploration, instruments and hardware used to maintain and monitor crew and vehicle health must become more integrated, reliable, and efficient. By combining a carbon dioxide (CO2) removal system with a resource recovery system like a Sabatier or Bosch reactor, the waste gas from the removal system can be converted into valuable resources that help reduce reliance on ground resupply. Due to the high-pressure nature of the Sabatier and Bosch reactions, the vent gas from most CO2 removal systems will need to be compressed before it can be processed. In order to prevent condensation in the compressor of the recovery system, it is critical to ensure that the vent stream from the CO2 removal system does not contain an excess of water. There are currently three different CO2 removal systems that are being developed as candidates for exploration missions. Each of these systems will be evaluated as a technology demonstration on ISS, and vent gas samples will be collected in Summa sampling canisters fitted with Entech valves. Due to the need to measure low levels of water in these samples, it was not possible to use the current ISS miniature grab sample containers (GSCs) to collect these samples. The Summa containers, which were used to collect archive samples during Shuttle missions, have a different surface treatment that makes it possible to measure the low levels of water in samples collected in these containers. This paper will provide some background on the CO2 removal systems being evaluated for exploration missions as well as results from ground-based testing of the current miniature GSCs and Summa canisters. Details on the development of the analytical method and the plan for preparing the canisters that will be used for in-flight sampling are also discussed.

Steven W Beck↗

X-ray Mapping of Terrestrial and Extraterrestrial Materials Using the Electron Microprobe

Lunar samples returned from the Apollo program motivated development of the Bence-Albee algorithm for the rapid and accurate analysis of lunar materials, and established interlaboratory comparability through its common use. In the analysis of mineral and rock fragments it became necessary to combine micro- and macroscopic analysis by coupling electron-probe microanalysis (EPMA) with automated stage point counting. A coarse grid that included several thousand points was used, and initially wavelength-dispersive (WDS) and later energydispersive (EDS) data were acquired at discrete stage points using approx. 5 sec count times. A approx 50 micrometer beam diameter was used for WDS and up to 500 micrometer beam diameter for EDS analysis. Average analyses of discretely sampled phases were coupled with the point count data to calculate the bulk composition using matrix algebra. Use of a defocused beam resulted in a contribution from multiple phases to each analytical point, and the analytical data were deconvolved relative to end-member phase chemistry on the fly. Impressive agreement was obtained between WDS and EDS measurements as well as comparison with bulk chemistry obtained by other methods. In the 30 years since these methods were developed, significant improvements in EPMA automation and computer processing have taken place. Digital beam control allows routine collection of x-ray maps by EDS, and stage mapping for WDS is conducted continuously at slew speed and incrementally by sampling at discrete points. Digital pulse processing in EDS systems has significantly increased the throughput for EDS mapping, and the ongoing development of Si-drift detector systems promises mapping capabilities rivaling WDS systems. Spectrum imaging allows a data cube of EDS spectra to be acquired and sophisticated processing of the original data is possible using matrix algebra techniques. The study of lunar and meteoritic materials includes the need to conveniently: (1) Characterize the sample at microscopic and macroscopic scales with relatively high sensitivity, (2) Determine the modal abundance of minerals, and (3) Identify and relocate discrete features of interest in terms of size and chemistry. The coupled substitution of cations in minerals can result in significant variation in mineral chemistry, but at similar average Z, leading to poor backscattered-electron (BSE) contrast discrimination of mineralogy. It is necessary to discriminate phase chemistry at both the trace element level and the major element level. To date, the WDS of microprobe systems is preferred for mapping due to high throughput and the ability to obtain the necessary intensity to discriminate phases at both trace and major element concentrations. It is desirable to produce fully quantitative compositional maps of geological materials, which requires the acquisition of k-ratio maps that are background and dead-time corrected, and which have been corrected by phi(delta z> or an equivalent algorithm at each pixel. To date, turnkey systems do not allow the acquisition of k-ratio maps and the rigorous correction in this manner. X-ray maps of a chondrule from the Ourique meteorite, and a comb-layered xenolith from the San Francisco volcanic field, have been analyzed and processed to extract phase information. The Ourique meteorite presents a challenge due to relatively low BSE contrast, and has been studied using spectrum imaging. X-ray maps for Si, Mg, and FeK(alpha) were used to produce RGB images. The xenolith sample contains sector-zoned augite, olivine, plagioclase, and basaltic glass. X-ray maps were processed using Lispix and ImageJ software to produce mineral phase maps. The x-ray maps for Mg, Ca, and Ti were used with traceback to generate binary images that were converted to RGB images. These approaches are successful in discriminating phases, but it is desirable to achieve the methods that were used on lunar samples 30 years ago on current microprobe systems. Curnt research includes x-ray mapping analysis of the Dalgety Downs chondrite by micro x-ray fluorescence and spectrum imaging, in collaboration with Kenny Witherspoon of IXRF Systems and Dale Newbury of NIST.

Carpenter, P.↗

Dynamic Acoustic Detection of Boundary Layer transition

The wind tunnel investigation into the acoustic nature of boundary layer transition using miniature microphones. This research is the groundwork for entry into the National Transonic Facility (NTF) at the NASA Langley Research Center (LaRC). Due to the extreme environmental conditions of NTF testing, low temperatures and high pressures, traditional boundary layer detection methods are not available. The emphasis of this project and further studies is acoustical sampling of a typical boundary layer and environmental durability of the miniature microphones. The research was conducted with the 14 by 22 Foot Subsonic Tunnel, concurrent with another wind tunnel test. Using the resources of LaRC, a full inquiry into the feasibility of using Knowles Electronics, Inc. EM-3086 microphones to detect the surface boundary layer, under differing conditions, was completed. This report shall discuss the difficulties encountered, product performance and observations, and future research adaptability of this method.

Grohs, Jonathan R.↗

Method and apparatus for supercooling and solidifying substances

An enclosure provides a containerless environment in which a sample specimen is positioned. The specimen is heated in the containerless environment, and the specimen melt is dropped through the tube in which it cools by radiation. The tube is alternatively backfilled with an inert gas whereby the specimen melt cools by both radiation and convection during its free fall. During the free fall, the sample is in a containerless, low-gravity environment which enhances supercooling in the sample and prevents sedimentation and thermal convection influences. The sample continues to supercool until nucleation occurs which is detected by silicon photovoltaic detectors. The sample solidifies after nucleation and becomes completely solid before entering the detachable catcher. The amount of supercooling of the specimen can be measured by knowing the cooling ratio and determining the time for nucleation to occur.

Lacy, L. L.↗

Capacitive acoustic wave detector and method of using same

A capacitor having two substantially parallel conductive faces is acoustically coupled to a conductive sample end such that the sample face is one end of the capacitor. A non-contacting dielectric may serve as a spacer between the two conductive plates. The formed capacitor is connected to an LC oscillator circuit such as a Hartley oscillator circuit producing an output frequency which is a function of the capacitor spacing. This capacitance oscillates as the sample end coating is oscillated by an acoustic wave generated in the sample by a transmitting transducer. The electrical output can serve as an absolute indicator of acoustic wave displacement.

Yost, William T.↗