Search NASA⌕ Search

SEARCH · Search NASA

Results for “source configuration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,765 records · Page 98

Monte Carlo Assessments of Absorbed Doses to the Hands of Radiopharmaceutical Workers Due to Photon Emitters

This paper describes the characterization of radiation doses to the hands of nuclear medicine technicians resulting from the handling of radiopharmaceuticals. Radiation monitoring using ring dosimeters indicates that finger dosimeters that are used to show compliance with applicable regulations may overestimate or underestimate radiation doses to the skin depending on the nature of the particular procedure and the radionuclide being handled. To better understand the parameters governing the absorbed dose distributions, a detailed model of the hands was created and used in Monte Carlo simulations of selected nuclear medicine procedures. Simulations of realistic configurations typical for workers handling radiopharmaceuticals were performedfor a range of energies of the source photons. The lack of charged-particle equilibrium necessitated full photon-electron coupled transport calculations. The results show that the dose to different regions of the fingers can differ substantially from dosimeter readings when dosimeters are located at the base of the finger. We tried to identify consistent patterns that relate the actual dose to the dosimeter readings. These patterns depend on the specific work conditions and can be used to better assess the absorbed dose to different regions of the exposed skin.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of 1D and 2D CSR Models with Application to the FERMI@ELETTRA Bunch Compressors

We compare our 2D mean field (Vlasov-Maxwell) treatment of coherent synchrotron radiation (CSR) effects with 1D approximations of the CSR force which are commonly implemented in CSR codes. In our model we track particles in 4D phase space and calculate 2D forces [1]. The major cost in our calculation is the computation of the 2D force. To speed up the computation and improve 1D models we also investigate approximations to our exact 2D force. As an application, we present numerical results for the Fermi{at}Elettra first bunch compressor with the configuration described in [1].

2D↗

Gas sensitive materials for gas detection and method of making

A gas sensitive material comprising SnO2 nanocrystals doped with In2O3 and an oxide of a platinum group metal, and a method of making the same. The platinum group metal is preferably Pd, but also may include Pt, Ru, Ir, and combinations thereof. The SnO2 nanocrystals have a specific surface of 7 or greater, preferably about 20 m2/g, and a mean particle size of between about 10 nm and about 100 nm, preferably about 40 nm. A gas detection device made from the gas sensitive material deposited on a substrate, the gas sensitive material configured as a part of a current measuring circuit in communication with a heat source.

36 MATERIALS SCIENCE↗

Gas sensitive materials for gas detection and methods of making

A gas sensitive material comprising SnO.sub.2 nanocrystals doped with In.sub.2O.sub.3 and an oxide of a platinum group metal, and a method of making the same. The platinum group metal is preferably Pd, but also may include Pt, Ru, Ir, and combinations thereof. The SnO.sub.2 nanocrystals have a specific surface of 7 or greater, preferably about 20 m2/g, and a mean particle size of between about 10 nm and about 100 nm, preferably about 40 nm. A gas detection device made from the gas sensitive material deposited on a substrate, the gas sensitive material configured as a part of a current measuring circuit in communication with a heat source.

36 MATERIALS SCIENCE↗

Environmentally responsive optical microstructured hybrid actuator assemblies and applications thereof

Microstructured hybrid actuator assemblies in which microactuators carrying designed surface properties to be revealed upon actuation are embedded in a layer of responsive materials. The microactuators in a microactuator array reversibly change their configuration in response to a change in the environment without requiring an external power source to switch their optical properties.

36 MATERIALS SCIENCE↗

Modeling and Simulation of Membrane-Based Dehumidification and Energy Recovery Process

This paper introduces a first-order physics-based model that accounts for the fundamental heat and mass transfer between a humid-air vapor stream on feed side to another flow stream on permeate side. The model comprises a few optional submodels for membrane mass transport; and it adopts a segment-by-segment method for discretizing heat and mass transfer governing equations for flow streams on feed and permeate sides. The model is able to simulate both dehumidifiers and energy recovery ventilators in parallel-flow, cross-flow, and counter-flow configurations. The predicted tresults are compared reasonably well with the measurements. The open-source codes are written in C++. The model and open-source codes are expected to become a fundament tool for the analysis of membrane-based dehumidification in the future.

Gao, Zhiming↗

Evaporation-driven engines

Evaporation-driven engines are disclosed herein. An example engine can include a water source having a high humidity zone proximate the surface of the water source, a supporting structure, and a hygroscopic material disposed on the supporting structure and configured to generate mechanical force in response to a changing relative humidity. The hygroscopic material can be repeatedly exposed to the high humidity zone and removed from the high humidity zone thereby causing the hygroscopic material to generate mechanical force.

Chen, Xi↗

Ultraviolet (UV) light emitting device (LED) driven photocathode

An apparatus includes an electromechanical x-ray generator (MEXRAY) configured to charged capacitors using a small, high-voltage direct current. The apparatus also includes an ultraviolet (UV) light emitting diode (LED) driven photocathode device configured to control/modulate an electron dose rate of the MEXRAY or other vacuum DC, source.

Watson, Scott Avery↗

Conceptual configurations of an accelerator-driven subcritical system utilizing minor actinides

This paper purposes an Accelerator-Driven Subcritical (ADS) system which utilizes the Minor Actinides (MAs) from the US spent nuclear fuel inventory. A mobile fuel concept with micro-particles suspended in the liquid metal is adopted in the purposed system to avoid difficulties of developing and testing new MAs solid fuel forms. Three ADS configurations were developed and analyzed using the Monte Carlo fuel burnup methodology. The analyses demonstrated the capabilities of the proposed system to utilize the MAs and to dispose of the US spent nuclear fuels. (authors)

43 PARTICLE ACCELERATORS↗

Contamination Control: Challenges and Innovative Design Solutions utilized at Chalk River Laboratories - 19263

CNL has operated research reactors at the Chalk River Laboratories (CRL) site since 1947, generating a variety of spent nuclear fuel wastes produced by irradiating metallic uranium and other prototype fuels. This legacy waste has been stored in below-grade, vertical cylindrical steel and concrete structures known as Tile Holes. Ongoing monitoring of the legacy waste has identified moisture resulting from incomplete drying prior to emplacement, surface water and humidity. The undesirable storage conditions result in corrosion of both the legacy waste and the storage containers. Continued storage in these conditions may result in further degradation of the storage container and contamination of the surrounding environment. In 2004, the Fuel Packaging and Storage (FPS) Project was initiated, with the objective to develop a complete system to safely retrieve legacy waste from these Tile Holes as well as provide a stable storage environment until a final long-term management plan is established. Contamination control during retrieval, transfer and repackaging operations is critical for personnel and environmental safety. The significant challenges with retrieval of the legacy waste from the Tile Holes includes management of loose collateral liquid and solids that will be brought into the system, with the retrieved waste container. During the retrieval, transfer and repackaging operation, the challenge was to: 1) Prevent an environmental release by potentially transferring these contaminants onto the external surface of the Tile Hole Array; 2) Prevent an environmental release and ensure personnel safety while transporting the legacy waste; 3) Control release of contaminants into the new clean storage container while preventing contamination of the packaging equipment. To address the first source of contamination, a debris guide liner capable of interfacing with multiple Tile Hole configurations was integrated within the Retrieval Flask to limit contamination of the flask interior and to direct collateral liquids and solids back into the Tile Hole. The system uses a multi-function sealed Shield Gate and Drip Tray to retain and prevent the contaminants from escaping while transferring the legacy waste. This gate, along with a thin walled, Disposable Debris Guide Liner (DDGL) is an innovative solution developed to control the flow characteristics of the residual waste and to contain the waste to protect the internal components of the repackaging equipment. The development of the complete solution was further challenged as the DDGL must not tear or rip and must compact inside the new storage containers for a range of legacy waste storage containers. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Prompt Neutron Decay Constants in a Highly Enriched Uranium-Lead Copper Reflected System

Rossi-{alpha} measurements were performed on highly enriched uranium (HEU)-lead copper reflected systems to determine the prompt neutron decay constants. These constants represent an eigenvalue characteristic of these particular critical configurations, which can be experimentally measured by the Rossi-a or pulse neutron source techniques and calculated by a deterministic or Monte Carlo method. In the measurements presented in this summary, highly enriched uranium interleaved with lead plates and reflected with copper were assembled to a high multiplication and the prompt neutron decay constants were determined by the Rossi-{alpha} technique. This research intended to benchmark the lead neutron cross sections; it was a collaboration between the Japanese Atomic Energy Agency (JAEA) Fast Critical Assembly Facility (FCA) in Tokai, Japan and the Los Alamos National Laboratory (LANL) in the U.S. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Appliance level battery-based energy storage

A powered building system that includes an electric power distribution system configured to distribute electrical power to a plurality of receptacles; one or more load sources; and one or more battery systems associated with: a respective receptacle of the plurality of receptacles and a respective load source of the one or more load sources.

Griffith, Saul Thomas↗

Conformational Variations of Both Phosphodiesterase-5 and Inhibitors Provide the Structural Basis for the Physiological Effects of Verdenafil and Sildenafil

Vardenafil has higher affinity to phosphodiesterase-5 (PDE5) than sildenafil and lower administered dosage for the treatment of erectile dysfunction. However, the molecular basis for these differences is puzzling because two drugs have similar chemical structures. Reported here is a crystal structure of the fully active and nonmutated PDE5A1 catalytic domain in complex with vardenafil. The structure shows that the conformation of the H-loop in the PDE5A1-vardenafil complex is different from those of any known structures of the unliganded PDE5 and its complexes with the inhibitors. In addition, the molecular configuration of vardenafil differs from that of sildenafil when bound to PDE5. It is noteworthy that the binding of vardenafil causes loss of the divalent metal ions that have been observed in all the previously published PDE structures. The conformational variation of both PDE5 and the inhibitors provides structural insight into the different potencies of the drugs.

36 MATERIALS SCIENCE↗

Deterministic Modeling of the High Temperature Test Reactor with DRAGON-HEXPEDITE

The Idaho National Laboratory (INL) is tasked with the development of reactor physics analysis capability of the Next Generation Nuclear Power (NGNP) project. In order to examine the INL’s current prismatic reactor analysis tools, the project is conducting a benchmark exercise based on modeling the High Temperature Test Reactor (HTTR). This exercise entails the development of a model for the initial criticality, a 19 fuel column thin annular core, and the fully loaded core critical condition with 30 fuel columns. Special emphasis is devoted to physical phenomena and artifacts in HTTR that are similar to phenomena and artifacts in the NGNP base design. The DRAGON code is used in this study since it offers significant ease and versatility in modeling prismatic designs. DRAGON can generate transport solutions via Collision Probability (CP), Method of Characteristics (MOC) and Discrete Ordinates (Sn). A fine group cross-section library based on the SHEM 281 energy structure is used in the DRAGON calculations. The results from this study show reasonable agreement in the calculation of the core multiplication factor with the MC methods, but a consistent bias of 2-3% with the experimental values is obtained. This systematic error has also been observed in other HTTR benchmark efforts and is well documented in the literature. The ENDF/B VII graphite and U 235 cross sections appear to be the main source of the error. The isothermal temperature coefficients calculated with the fully loaded core configuration agree well with other benchmark participants but are 40% higher than the experimental values. This discrepancy with the measurement partially stems from the fact that during the experiments the control rods were adjusted to maintain criticality, whereas in the model, the rod positions were fixed. In addition, this work includes a brief study of a cross section generation approach that seeks to decouple the domain in order to account for neighbor effects. This spectral interpenetration is a dominant effect in annular HTR physics. This analysis methodology should be further explored in order to reduce the error that is systematically propagated in the traditional generation of cross sections.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Performance Assessment of a New Gamma Spectroscopy Toolkit: Peak Doctor and the Spectral Nondestructive Assay Platform (SNAP) - 17397

High resolution gamma spectroscopy (HRGS) is a widely used technique for non-destructive characterization of nuclear materials, and assay of radioactive waste. The ability to accurately evaluate raw spectral data is an important step in producing high-quality results. A spectral analysis application known as Peak Doctor has been developed under a Cooperative Research and Development Agreement (CRADA) between LANL and Pajarito Scientific Corporation (PSC). The software has undergone several years of testing and validation by the Radioactive Waste Characterization Team of the LANL Waste Management Services Group (WM-SVS). PeakDoctor is designed to work with the Spectral Nondestructive Assay Platform (SNAP{sup TM}) to provide a complete HRGS analysis engine. SNAP{sup TM} performs model specific corrections for attenuation and geometry. These applications are the major components of a new toolkit designed primarily for portable far-field non-destructive assay. Peak Doctor performs a very accurate peak fit analysis with the goal of improving upon the capabilities of existing commercially available routines. It is designed to be user-configurable and can be customized to any given type of detector and any given type of spectrum. Peak Doctor was developed to resolve many of the inherent complexities in gamma ray spectra including overlapping peaks, complex multiplet regions, large step peaks, backscatter regions and Compton edges. Unlike most spectral analysis platforms, Peak Doctor does not rely on the energy calibration and detector resolution parameters that are saved by the operator in the spectrum file. Instead, key parameters are pre-defined for individual detectors. The software fits a continuum using a series of splines between a series of junctions or 'knots'. Fitting techniques are used to join the splines together to create a near-continuous multi-element curve. Optimizing the location of the knots is one of Peak Doctor's most powerful features. The knots are initially configured using a pre-defined list and are removed or added automatically during the fitting process. Knots are also created when new features are identified such as Step Peaks and Compton Edges. The user can also manually specify knots in order to improve the continuum fit. The initial fit is improved on by removing any outlier regions (which are converted to peaks) and the continuum fitting process is repeated. At this stage, an experienced user can work interactively with the fit by manually converting peak regions to continuum or vice versa. The final step is to fit a series of peaks above the continuum based on detector parameters. Single and multiplet peaks are then processed by either the tailing (piecewise) or non-tailing (Gaussian) Levenberg Marquardt non-linear peak fitting routine depending on the user defined selection. Only a rough knowledge of the detector characteristics (energy calibration and resolution) is required for the fitting process to proceed with good accuracy. Any peaks that are missed can be manually added by the user and will also be fitted. Discontinuities in the peak / continuum fit can be rapidly identified by reviewing the 'residuals scale' plot. For waste streams that are well characterized, it is often the case that routinely encountered spectra will have similar peaks and continuum features. For these cases a handy 'One Step' method is available that proceeds in an automated fashion without user interaction. Peak Doctor has been configured with a set of default spectrum types including plutonium / transuranic waste (including Weapons Grade Pu, Heat Source Pu, Am-241, Am-243 and Np-237), depleted or enriched uranium, nuclear power plant / intermediate level waste (with fission and activation products such as Cs-137 and Co-60) as well as Naturally Occurring Radioactive Materials (NORM). The user can easily add new spectrum types for specific waste streams or other types of radiological / special nuclear materials. The output from PeakDoctor (including net peak area, centroid energy and a list of minimum detectable activity levels at pre-defined regions) is used by SNAP{sup TM} to complete the data analysis process. Isotope activities are calculated using configurable template-driven geometry and attenuation correction methods. The software accounts for matrix and container wall effects, collimator / angular corrections, detector efficiency (based on calibration curves) and stand-off distance. SNAP{sup TM} uses published algorithms incorporating a series of decision points during its operation to allow the analyst to provide logical input to guide the software during the analysis of each unique spectrum. The Peak Doctor / SNAP{sup TM} toolkit has been extensively tested and validated under a variety of conditions using 'benchmark' reference spectra. Test scenarios reported include HPGe-based measurements of well characterized uranium and plutonium standards and radioactive sources with a variety of different geometries and matrix materials including surrogate drums and boxes. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Bright spots in 1 MA X pinches as a function of wire number and material

Bright, intense x-ray sources with extreme plasma parameters (micropinch plasmas) have previously been characterized at 0.1-0.4 MA, but the scaling of such sources at higher current is poorly understood. The x-ray source size and radiation power of 1 MA X pinches were studied as a function of wire material (Al, Ti, Mo, and W) and number (1-, 2-, 8-, 32-, and 64-wire configurations). The smallest bright spots observed were from 32-wire tungsten X pinches, which produced {<=}11-16 {mu}m, {approx}2 J, 1-10 GW sources of 3-5 keV radiation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Determination of electron energy, spectral width, and beam divergence at the exit window for clinical megavoltage x-ray beams

Monte Carlo simulations of x-ray beams typically take parameters of the electron beam in the accelerating waveguide to be free parameters. In this paper, a methodology is proposed and implemented to determine the energy, spectral width, and beam divergence of the electron source. All treatment head components were removed from the beam path, leaving only the exit window. With the x-ray target and flattener out of the beam, uncertainties in physical characteristics and relative position of the target and flattening filter, and in spot size, did not contribute to uncertainty in the energy. Beam current was lowered to reduce recombination effects. The measured dose distributions were compared with Monte Carlo simulation of the electron beam through the treatment head to extract the electron source characteristics. For the nominal 6 and 18 MV x-ray beams, the energies were 6.51{+-}0.15 and 13.9{+-}0.2 MeV, respectively, with the uncertainties resulting from uncertainties in the detector position in the measurement and in the stopping power in the simulations. Gaussian spectral distributions were used, with full widths at half maximum ranging from 20{+-}4% at 6 MV to 13{+-}4% at 18 MV required to match the fall-off portion of the percent-depth ionization curve. Profiles at the depth of maximum dose from simulations that used the manufacturer-specified exit window geometry and no beam divergence were 2-3 cm narrower than measured profiles. Two simulation configurations yielding the measured profile width were the manufacturer-specified exit window thickness with electron source divergences of 3.3 degree sign at 6 MV and 1.8 deg. at 18 MV and an exit window 40% thicker than the manufacturer's specification with no beam divergence. With the x-ray target in place (and no flattener), comparison of measured to simulated profiles sets upper limits on the electron source divergences of 0.2 deg. at 6 MV and 0.1 deg. at 18 MV. A method of determining source characteristics without mechanical modification of the treatment head, and therefore feasible in clinics, is presented. The energies and spectral widths determined using this method agree with those determined with only the exit window in the beam path.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A lightweight, user-configurable detector ASIC digital architecture with on-chip data compression for MHz X-ray coherent diffraction imaging

Today, most X-ray pixel detectors used at light sources transmit raw pixel data off the detector ASIC. With the availability of more advanced ASIC technology nodes for scientific application, more digital functionalities from the computing domains (e.g., compression) can be integrated directly into a detector ASIC to increase data velocity. In this paper, we describe a lightweight, user-configurable detector ASIC digital architecture with on-chip compression which can be implemented in 130 nm technologies in a reasonable area on the ASIC periphery. In addition, we present a design to efficiently handle the variable data from the stream of parallel compressors. The architecture includes user-selectable lossy and lossless compression blocks. The impact of lossy compression algorithms is evaluated on simulated and experimental X-ray ptychography datasets. This architecture is a practical approach to increase pixel detector frame rates towards the continuous 1 MHz regime for not only coherent imaging techniques such as ptychography, but also for other diffraction techniques at X-ray light sources.

47 OTHER INSTRUMENTATION↗