Search NASA⌕ Search

SEARCH · Search NASA

Results for “surface instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,765 records · Page 98

Development of low-cost technology for the next generation of high efficiency solar cells composed of earth abundant elements

The development of renewable, affordable, and environmentally conscious means of generating energy on a global scale represents a grand challenge of our time. Due to the “permanence” of radiation from the sun, solar energy promises to remain a viable and sustainable power source far into the future. Established single-junction photovoltaic technologies achieve high power conversion efficiencies (pce) near 20% but require complicated manufacturing processes that prohibit the marriage of large-scale throughput (e.g. on the GW scale), profitability, and quality control. Our approach to this problem begins with the synthesis of nanocrystals of semiconductor materials comprising earth abundant elements and characterized by material and optoelectronic properties ideal for photovoltaic applications, namely Cu2ZnSn(S,Se)4 (CZTSSe). Once synthesized, such nanocrystals are formulated into an ink, coated onto substrates, and processed into completed solar cells in such a way that enables scale-up to high throughput, roll-to-roll manufacturing processes. This project aimed to address the major limitation to CZTSSe solar cell pce’s – the low open-circuit voltage (Voc) reported throughout literature for devices comprised of this material. Throughout the project significant advancements have been made in fundamental understanding of the CZTSSe material and device limitations associated with this material system. Additionally, notable improvements have been made to our nanocrystal based processing technique to alleviate performance limitations due to the identified device limitations. Notably, (1) significant improvements have been made in reducing intra- and inter-nanoparticle heterogeneity, (2) improvements in device performance have been realized with novel cation substitution in Ge-alloyed CZTGeSSe absorbers, (3) systematic analysis of absorber sintering has been conducted to optimize the selenization process for large grain CZTSSe absorbers, (4) novel electrical characterization analysis techniques have been developed to identify significant limitations to traditional electrical characterization of CZTSSe devices, and (5) the developed electrical analysis techniques have been used to identify the role that band gap and electrostatic potential fluctuations have in limiting device performance for this material system. The device modeling and characterization of CZTSSe undertaken with this project have significant implications for the CZTSSe research community, as the identified limitations due to potential fluctuations are expected to be a performance limitation to high-efficiency CZTSSe devices fabricated from all current processing techniques. Additionally, improvements realized through enhanced absorber processing conditions to minimize nanoparticle and large-grain absorber heterogeneity are suggested to be beneficial processing improvements which should be applied to CZTSSe devices fabricated from all processing techniques. Ultimately, our research has indicated that improved performance for CZTSSe will be achieved through novel absorber processing which minimizes defect formation, elemental losses, secondary phase formation, and compositional uniformity in CZTSSe absorbers; we believe this novel absorber processing can be achieved through nanocrystal based processing of CZTSSe which is an active area of research at the conclusion of this award. While significant fundamental understanding of CZTSSe and the performance limitations associated with this material system, as well as notable improvements in the processing of nanocrystal based CZTSSe absorbers, have been achieved under this project, the limitation of two years of research funding towards our goals prevents further significant advancements directly identified through pce. improvements relative to those reported herein. As the characterization and modeling subtask of this project has been the main driving force for understanding device limitations, the conclusions of this analysis have just recently been applied to the processing of nanocrystal based CZTSSe absorbers -- with notable success. We expect the notable fundamental understanding of device limitations and absorber sintering achieved under this project will lead to significant improvements in device performance for CZTSSe devices in the near future for devices fabricated from a variety of processing techniques

14 SOLAR ENERGY↗

Tethered Balloon System merged (TBSmerged) Value-Added Product Report

TBSmerged integrates data from instruments flown on ARM’s Tethered Balloon System missions that collect in situ measurements of temperature, humidity, wind speed, wind direction, and aerosol properties with estimates of cloud base and boundary layer height from a surface-based ceilometer to improve the ease of use of TBS datasets. TBSmergedincloud includes supercooled liquid water content (tbsslwc) measurements collected within the cloud.

54 ENVIRONMENTAL SCIENCES↗

Circularly polarized antennas for active holographic imaging through barriers

Circularly-polarized antennas and their methods of use for active holographic imaging through barriers. The antennas are dielectrically loaded to optimally match the dielectric constant of the barrier through which images are to be produced. The dielectric loading helps to remove barrier-front surface reflections and to couple electromagnetic energy into the barrier.

47 OTHER INSTRUMENTATION↗

Composite drill pipe and method for forming same

A lightweight and durable drill pipe string capable of short radius drilling formed using a composite pipe segment formed to include tapered wall thickness ends that are each defined by opposed frustoconical surfaces conformed for self-aligning receipt and intimate bonding contact within an annular space between corresponding surfaces of a coaxially nested set of metal end pieces and a set of nonconductive sleeves. The distal peripheries of the nested end pieces and sleeves are then welded to each other and the sandwiched and bonded portions are radially pinned. The composite segment may include imbedded conductive leads and the axial end portions of the end pieces are shaped to form a threaded joint with the next pipe assembly that includes contact rings in the opposed surfaces of the pipe joint for contact together.

47 OTHER INSTRUMENTATION↗

Apparatus and method for temperature mapping a turbine component in a high temperature combustion environment

Method and system for calibrating a thermal radiance map of a turbine component in a combustion environment. At least one spot (18) of material is disposed on a surface of the component. An infrared (IR) imager (14) is arranged so that the spot is within a field of view of the imager to acquire imaging data of the spot. A processor (30) is configured to process the imaging data to generate a sequence of images as a temperature of the combustion environment is increased. A monitor (42, 44) may be coupled to the processor to monitor the sequence of images of to determine an occurrence of a physical change of the spot as the temperature is increased. A calibration module (46) may be configured to assign a first temperature value to the surface of the turbine component when the occurrence of the physical change of the spot is determined.

47 OTHER INSTRUMENTATION↗

Shielding Analyses for VISION Beam Line at SNS

Full-scale neutron and gamma transport analyses were performed to design shielding around the VISION beam line, instrument shielding enclosure, beam stop, secondary shutter including a temporary beam stop for the still closed neighboring beam line to meet requirement is to achieve dose rates below 0.25 mrem/h at 30 cm from the shielding surface. The beam stop and the temporary beam stop analyses were performed with the discrete ordinate code DORT additionally to Monte Carlo analyses with the MCNPX code. Comparison of the results is presented.

Popova, Irina↗

Solute chemistry for streams draining geomorphic features and varying land cover gradients in the East River watershed, Colorado

This dataset contains solute chemistry data and GPS coordinates for surface water samples collected in the East River watershed in the Elk and West Elk Ranges of Colorado from August 3rd through August 11th, 2022. Samples were collected from streams and groundwater seeps as part of a comprehensive analysis within the watershed of how different geomorphic features (such as landslides and rock glaciers) along with variations in land cover (such as the presence of vegetation) affect stream water quality in this Rocky Mountain headwater environment. This dataset includes concentrations of the following in a single csv file: fluoride, chloride, sulfate, nitrate, calcium, potassium, magnesium, sodium, silicon, and total organic carbon (TOC). All concentrations are reported in mg/L. The sulfate data in this version have been updated to account for an earlier ion chromatograph instrument method error whereby sulfate and bromide peaks overlapped in calibration solution samples, biasing calculated sulfate concentrations low by 30-50%. Sulfate data reported herein are from a re-run of the samples performed in December 2024 using a corrected instrument method. All samples were stored under refrigerated conditions and filtered on initial collection.

54 ENVIRONMENTAL SCIENCES↗

TRACER-Coastal Urban Boundary-Layer Interactions with Convection (TRACER-CUBIC) Field Campaign Report

To better understand the complicated web of processes governing convective cloud life cycle and aerosol-convection interactions, the U.S. Department of Energy (DOE)’s Atmospheric Radiation Measurement (ARM) user facility supported deployment of a variety of advanced atmospheric measurement systems to the greater Houston, Texas, area from 1 October 2021 to 30 September 2022 as part of the Tracking Aerosol Convection Interactions Experiment (TRACER). Houston was selected as a study area because isolated convection and a variety of aerosol conditions are common in this region. This one-year ARM Mobile Facility (AMF) deployment featured a four-month intensive operational period (IOP) during summer 2022 (1 June–30 September). The ARM instrumentation was deployed at three sites along an east-west transect from La Porte, Texas to an ancillary site in a less-polluted rural region southwest of downtown Houston (Figure 1). At the La Porte Site, which is located near the Houston ship channel in an area that experiences significant pollution, the first ARM Mobile Facility (AMF1) was deployed. During the IOP, the ARM tethered balloon system (TBS) operated at the ancillary site. The second-generation C-Band Scanning ARM Precipitation Radar (CSAPR) operated near Pearland, Texas, roughly halfway between the Laporte and ancillary sites. As part of the TRACER- Coastal Urban Boundary-Layer Interactions with Convection (CUBIC) project, three boundary-layer profiling systems) were deployed along a north-south transect spanning from the University of Houston Coastal Center to the Aldine site north of downtown Houston (also blue dot in Figure 1) during the TRACER IOP. These systems included the National Oceanic and Atmospheric Administration (NOAA) National Severe Storms Laboratory CLAMPS2 (C2), which was deployed at the UHCC, the University of Wisconsin SPARC, which was deployed at the ARM CSAPR site near Pearland (orange diamond in middle of map in Figure 1), and the University of Oklahoma CLAMPS1 (C1), which was deployed at Aldine. These three systems have been successfully operated in various field campaigns, providing data sets that collectively offer new insights into atmospheric-boundary-layer (ABL) processes, sea-breeze (SB) circulations, and convection initiation (CI). For the TRACER IOP window, these systems ran continuously between 1 June and 26 September, 2022. Due to commitments to NOAA projects, the Doppler lidar at the UHCC site was not available until 24 June 2022. The CLAMPS and SPARC profiling systems are self-contained platforms that have benefited from several years of development and deployment. Instruments and data processing were maintained remotely, which made the 4-month deployment for the TRACER-CUBIC IOP period possible. The same basic instrument configuration comprises each system: a scanning Doppler wind lidar for flow characterization and passive profiler(s) for characterizing planetary-boundary-layer (PBL) thermodynamic properties. Each platform includes a Halo Streamline Doppler wind lidar, an Atmospheric Emitted Radiance Interferometer (AERI), and a surface meteorology station. CLAMPS1 and CLAMPS2 each also include a microwave radiometer (MWR, Figure 1d). The TRACER-CUBIC hypotheses included (i) Interactions of SB and urban circulations and how they affect the PBL structure in the Houston environment, causing spatially (horizontally and vertically) and temporally highly variable flow patterns, (ii) heat, moisture, and aerosol transport and mixing depend on these flow dynamics, and (iii) an improved understanding of the flow patterns and PBL structure are critical for investigating the processes leading to CI. To test these hypotheses, the project aimed at (i) characterizing SB circulations and their impacts on the diurnal evolution of the structure of the ABL, (ii) studying the evolution of Houston’s complex urban boundary layer, and (iii) identifying effects of urban-induced circulations on pre-convective environments. TRACER-CUBIC observations generally provide good coverage during the summer IOP. Initial screening of the data indicates a good number of cases with bay-breeze (BB) and/or SB signatures, local CI, and interesting boundary-layer features such as strong nocturnal low-level jets (LLJs, Table 1). The numbers listed in rows 3-5 in this table will be further updated as part of ongoing in-depth analyses and systematic identification of local circulations and CI events. More detailed information about the data availability and quality for each instrument is provided in the “readme” files that were submitted to the ARM Data Center along with each archived data sets. These “readme” files also provide instrument descriptions, information about the data collection and processing procedures, data formats, and any additional information relevant for further data analysis.

54 ENVIRONMENTAL SCIENCES↗

A metrological large range atomic force microscope with improved performance

A metrological large range atomic force microscope (Met. LR-AFM) has been set up and improved over the past years at Physikalisch-Technische Bundesanstalt (PTB). Being designed as a scanning sample type instrument, the sample is moved in three dimensions by a mechanical ball bearing stage in combination with a compact z-piezostage. Its topography is detected by a position-stationary AFM head. The sample displacement is measured by three embedded miniature homodyne interferometers in the x, y, and z directions. The AFM head is aligned in such a way that its cantilever tip is positioned on the sample surface at the intersection point of the three interferometer measurement beams for satisfying the Abbe measurement principle. In this paper, further improvements of the Met. LR-AFM are reported. A new AFM head using the beam deflection principle has been developed to reduce the influence of parasitic optical interference phenomena. Furthermore, an off-line Heydemann correction method has been applied to reduce the inherent interferometer nonlinearities to less than 0.3 nm (p-v). Versatile scanning functions, for example, radial scanning or local AFM measurement functions, have been implemented to optimize the measurement process. The measurement software is also improved and allows comfortable operations of the instrument via graphical user interface or script-based command sets. The improved Met. LR-AFM is capable of measuring, for instance, the step height, lateral pitch, line width, nanoroughness, and other geometrical parameters of nanostructures. Calibration results of a one-dimensional grating and a set of film thickness standards are demonstrated, showing the excellent metrological performance of the instrument.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Steady-state photoluminescent excitation characterization of semiconductor carrier recombination

Photoluminescence excitation spectroscopy is a contactless characterization technique that can provide valuable information about the surface and bulk recombination parameters of a semiconductor device, distinct from other sorts of photoluminescent measurements. For this technique, a temperature-tuned light emitting diode (LED) has several advantages over other light sources. The large radiation density offered by LEDs from near-infrared to ultraviolet region at a low cost enables efficient and fast photoluminescence measurements. A simple and inexpensive LED-based setup facilitates measurement of surface recombination velocity and bulk Shockley-Read-Hall lifetime, which are key parameters to assess device performance. Under the right conditions, this technique can also provide a contactless way to measure the external quantum efficiency of a solar cell.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Detection of lost alpha particle by concealed lost ion probe

Full orbit-following calculation is performed for the final orbit of the lost alpha particles, showing some orbits escaping from the last closed flux surface could be detected by a concealed lost ion probe (CLIP) installed under the shadow of the original first wall surface. While both passing and trapped orbits hit the same wall panel, detecting a trapped orbit by the CLIP is easier than detecting passing orbits. Whether the final orbit is detected or not is determined by the position of the reflection point. The CLIP successfully detects the trapped orbits, which are reflected before they hit to a first wall. Then the pitch angles of the orbits at the CLIP are close to and smaller than 90 deg. Optimization of the position of the CLIP in terms of broader detection window is investigated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

X-ray phase imaging with a paper analyzer

We present a simple x-ray phase imaging method that utilizes the sample-induced distortion of a high contrast random intensity pattern to quantitatively retrieve the two-dimensional phase map at the exit surface of a coherently illuminated sample. This reference pattern is created by placing a sheet of sandpaper in the x-ray beam, with the sample-induced distortion observed after propagation to the detector, a meter downstream. Correlation analysis comparing a single ''sample and sandpaper'' image to a reference ''sandpaper only'' image produces two sensitive differential phase contrast images, giving the sample phase gradient in vertical and horizontal directions. These images are then integrated to recover the projected phase depth of the sample. The simple experimental set-up, retention of flux, and the need for only a single sample image per reconstruction suggest that this method is of value in imaging a range of dynamic processes at both synchrotron and laboratory x-ray sources.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Light-Induced Tellurium Enrichment on CdZnTe Crystal Surfaces Detected by Raman Spectroscopy

CdZnTe (CZT) crystals can be grown under controlled conditions to produce high-quality crystals to be used as room-temperature radiation detectors. Even the best crystal growth methods result in defects, such as tellurium secondary phases, that affect the crystal's performance. In this study, CZT crystals were analyzed by micro-Raman spectroscopy. The growth of Te rich areas on the surface was induced by low-power lasers. The growth was observed versus time with low-power Raman scattering and was observed immediately under higher-power conditions. The detector response was also measured after induced Te enrichment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Pierre Auger Project and Enhancements

The current status of the scientific results of the Auger Observatory will be discussed which include spectrum, anisotropy in arrival directions, chemical composition analyses, and limits on neutrino and photon fluxes. A review of the Observatory detection systems will be presented. Auger has started the construction of its second phase which encompasses antennae for radio detection of cosmic rays, high-elevation telescopes, and surface plus muon detectors. Details will be presented on the latter, AMIGA (Auger Muons and Infill for the Ground Array), an Auger project consisting of 85 detector pairs each one composed of a surface water-Cherenkov detector and a buried muon counter. The detector pairs are arranged in an array with spacings of 433 and 750 m in order to perform a detailed study of the 10{sup 17} eV to 10{sup 19} eV spectrum region. Preliminary results on the performance of the 750 m array of surface detectors and the first muon counter prototype will be presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

RADIOLOGICAL SURVEY STATION DEVELOPMENT FOR THE PIT DISASSEMBLY AND CONVERSION PROJECT

The Savannah River National Laboratory (SRNL) has developed prototype equipment to demonstrate remote surveying of Inner and Outer DOE Standard 3013 containers for fixed and transferable contamination in accordance with DOE Standard 3013 and 10 CFR 835 Appendix B. When fully developed the equipment will be part of a larger suite of equipment used to package material in accordance with DOE Standard 3013 at the Pit Disassembly and Conversion Project slated for installation at the Savannah River Site. The prototype system consists of a small six-axis industrial robot with an end effector consisting of a force sensor, vacuum gripper and a three fingered pneumatic gripper. The work cell also contains two alpha survey instruments, swipes, swipe dispenser, and other ancillary equipment. An external controller interfaces with the robot controller, survey instruments and other ancillary equipment to control the overall process. SRNL is developing automated equipment for the Pit Disassembly and Conversion (PDC) Project that is slated for the Savannah River Site (SRS). The equipment being developed is automated packaging equipment for packaging plutonium bearing materials in accordance with DOE-STD-3013-2004. The subject of this paper is the development of a prototype Radiological Survey Station (RSS). Other automated equipment being developed for the PDC includes the Bagless transfer System, Outer Can Welder, Gantry Robot System (GRS) and Leak Test Station. The purpose of the RSS is to perform a frisk and swipe of the DOE Standard 3013 Container (either inner can or outer can) to check for fixed and transferable contamination. This is required to verify that the contamination levels are within the limits specified in DOE-STD-3013-2004 and 10 CFR 835, Appendix D. The surface contamination limit for the 3013 Outer Can (OC) is 500 dpm/100 cm2 (total) and 20 dpm/100 cm2 (transferable). This paper will concentrate on the RSS developments for the 3013 OC but the system for the 3013 Inner Can (IC) is nearly identical.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Microstructure and chemical wet etching characteristics of AlN films deposited by ac reactive magnetron sputtering

The influence of the surface morphology of a molybdenum underlayer on the crystallinity and etchability of reactively sputtered c-axis oriented aluminum nitride thin films was investigated. Atomic force microscopy, scanning electron microscopy, transmission electron microscopy, high resolution x-ray diffraction, and defect selective chemical etching were used to characterize the microstructure of the Mo and AlN films. 1000 nm thick films of AlN with a full width at half maximum (FWHM) of the x-ray rocking curve ranging from 1.1 deg. to 1.9 deg. were deposited on 300 nm thick Mo underlayers with a FWHM of around 1.5 deg. The Ar pressure during the Mo deposition had a critical effect on the Mo film surface morphology, affecting the structure of the subsequently deposited AlN films and, hence, their wet etching characteristics. AlN films deposited on Mo sputtered at a relatively high pressure could not be etched completely, while AlN films deposited on low pressure Mo etched more easily. Postdeposition etching of the Mo surface in Ar rf discharge prior to deposition of the AlN film was found to influence the formation of AlN residuals that were difficult to etch. Optimal rf plasma etching conditions were found, which minimized the formation of these residuals.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Aperture alignment in autocollimator-based deflectometric profilometers

During the last ten years, deflectometric profilometers have become indispensable tools for the precision form measurement of optical surfaces. They have proven to be especially suitable for characterizing beam-shaping optical surfaces for x-ray beamline applications at synchrotrons and free electron lasers. Deflectometric profilometers use surface slope (angle) to assess topography and utilize commercial autocollimators for the contactless slope measurement. To this purpose, the autocollimator beam is deflected by a movable optical square (or pentaprism) towards the surface where a co-moving aperture limits and defines the beam footprint. In this paper, we focus on the precise and reproducible alignment of the aperture relative to the autocollimator's optical axis. Its alignment needs to be maintained while it is scanned across the surface under test. The reproducibility of the autocollimator's measuring conditions during calibration and during its use in the profilometer is of crucial importance to providing precise and traceable angle metrology. In the first part of the paper, we present the aperture alignment procedure developed at the Advanced Light Source, Lawrence Berkeley National Laboratory, USA, for the use of their deflectometric profilometers. In the second part, we investigate the topic further by providing extensive ray tracing simulations and calibrations of a commercial autocollimator performed at the Physikalisch-Technische Bundesanstalt, Germany, for evaluating the effects of the positioning of the aperture on the autocollimator's angle response. The investigations which we performed are crucial for reaching fundamental metrological limits in deflectometric profilometry.

47 OTHER INSTRUMENTATION↗

Bragg grating inscription in photosensitive materials by an optical replication process

This paper examines the feasibility of producing multiplexed Bragg gratings for use as diffractive optical elements (DOEs) by coherent optical replication of a surface-relief phase grating into thick-film photosensitive materials. The use of such DOEs in light guide plates (LGPs) for optical imaging systems ensures energy-efficient light input into and output from LGPs and allows one to minimise their weight and size. We present simulation results for the interference structure fabrication process and recording of a series of multiplexed diffraction gratings in photosensitive materials. (paper)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗