Search NASA⌕ Search

SEARCH · Search NASA

Results for “timing error evaluation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,765 records · Page 98

Causal Analysis of the Inadvertent Contact with an Uncontrolled Electrical Hazardous Energy Source (120 Volts AC)

On September 25, 2013, a Health Physics Technician (HPT) was performing preparations to support a pneumatic transfer from the HFEF Decon Cell to the Room 130 Glovebox in HFEF, per HFEF OI 3165 section 3.5, Field Preparations. This activity involves an HPT setting up and climbing a portable ladder to remove the 14-C meter probe from above ball valve HBV-7. The HPT source checks the meter and probe and then replaces the probe above HBV-7, which is located above Hood ID# 130 HP. At approximately 13:20, while reaching past the HBV-7 valve position indicator switches in an attempt to place the 14-C meter probe in the desired location, the HPT’s left forearm came in contact with one of the three sets of exposed terminals on the valve position indication switches for HBV 7. This resulted in the HPT receiving an electrical shock from a 120 Volt AC source. Upon moving the arm, following the electrical shock, the HPT noticed two exposed electrical connections on a switch. The HPT then notified the HFEF HPT Supervisor, who in turn notified the MFC Radiological Controls Manager and HFEF Operations Manager of the situation. Work was stopped in the area and the hazard was roped off and posted to prevent access to the hazard. The HPT was escorted by the HPT Supervisor to the MFC Dispensary and then preceded to CFA medical for further evaluation. The individual was evaluated and released without any medical restrictions. Causal Factor (Root Cause) A3B3C01/A5B2C08: - Knowledge based error/Attention was given to wrong issues - Written Communication content LTA, Incomplete/situation not covered The Causal Factor (root cause) was attention being given to the wrong issues during the creation, reviews, verifications, and actual performance of HFEF OI-3165, which covers the need to perform the weekly source check and ensure placement of the probe prior to performing a “rabbit” transfer. This resulted in the hazard not being identified and mitigated in the procedure. Work activities with in HFEF-OI-3165 placed the HPT in proximity of an unmitigated hazard directly resulting in this event. Contributing Factor A3B3C04/A4B5C04: - Knowledge Based Error, LTA Review Based on Assumption That Process Will Not Change - Change Management LTA, Risks/consequences associated with change not adequately reviewed/assessed Prior to the pneumatic system being out of service, the probe and meter were not being source checked together. The source check issue was identified and addressed during the period of time when the system was out of service. The corrective actions for this issue resulted in the requirement that a meter and probe be source checked together as it is intended to be used. This changed the activity and required an HPT to weekly, when in use, remove and install the probe from above HBV-7 to meet the requirement of LRD 15001 Part 5 Article 551.5. Risks and consequences associated with this change were not adequately reviewed or assessed. Failure to identify the hazard associated with this change directly contributed to this event.

24 POWER TRANSMISSION AND DISTRIBUTION↗

SLOPE daily and 250 m gross primary productivity (GPP) for the CONUS, 2000-2019, Carbon Monitoring System (CMS)

The SatelLite Only Photosynthesis Estimation (SLOPE) GPP product is a daily, 250 m GPP dataset covering the Contiguous United States (CONUS) from 2000 to present with 1 day latency. Gross primary productivity (GPP) quantifies the amount of carbon dioxide (CO2) fixed by plants through photosynthesis. Although as a key quantity of terrestrial ecosystems, there is a lack of high-spatial-and-temporal-resolution, real-time, and observation-based GPP products. This product has been developed to address this critical gap, leveraging a number of MODIS land and atmosphere products. There are three distinct features of the SLOPE GPP production algorithm. (1) SLOPE couples machine learning models with MODIS atmosphere and land products to accurately estimate PAR. (2) SLOPE couples highly efficient and pragmatic gap-filling and filtering algorithms with surface reflectance acquired by both Terra and Aqua MODIS satellites to derive a soil-adjusted NIRv (SANIRv) dataset. (3) SLOPE couples a temporal pattern recognition approach with a long-term Crop Data Layer (CDL) product to predict dynamic C4 crop fraction. PAR, SANIRv and C4 fraction are used to drive a parsimonious model with only two slope parameters to estimate GPP along with a quantitative uncertainty on a per-pixel and daily basis. The slope GPP product has a R2 = 0.84 and a root-mean-square error (RMSE) of 1.65 gC m-2 d-1, evaluated against from 50 AmeriFlux eddy covariance sites (332 site-years). Archived data from 2000 to 2019 are publicly available at the NASA's Oak Ridge National Laboratory Distributed Active Archive Center (ORNL DAAC). Data from 2020 are available from the authors upon request. All data are projected in the standard MODIS Land Integerized Sinusoidal tile map projection. Each processing tile is in size of 4800 pixels by 4800 pixels, representing approximately 1200 km by 1200 km land region. In addition to the GPP product, SLOPE PAR, SANIRV, and C4 fraction, along with their uncertainties, are also released.

Jiang, Chongya↗

Error quantification of the Arrhenius blending rule for viscosity of hydrocarbon mixtures

Six hundred and seventy-five measurements of dynamic viscosity and density have been used to assess the prediction error of the Arrhenius blending rule for kinematic viscosity of hydrocarbon mixtures. Major trends within the data show that mixture complexity–binary to hundreds of components—and temperature are more important determinants of prediction error than differences in molecular size or hydrogen saturation between the components of the mixtures. Over the range evaluated, no correlation between prediction error and mole fractions was observed, suggesting the log of viscosity truly is linear in mole fraction, as indicated by the Arrhenius blending rule. Mixture complexity and temperature also impact molar volume and its prediction. However, a linear regression between the two model errors explains less than 20% of the observed variation, indicating that mixture viscosity and/or molar volume are not linear with respect to temperature and/or mixture complexity. Extensive discussion of the intermolecular forces and the geometric arrangement of molecules and vacancies in liquids, which ultimately determines its viscosity, is brought into context with the implicit approximations behind the Arrhenius blending rule. The complexity of this physics is not compatible with a simple algebraic correction to the model. However, sufficient data is now available to determine confidence intervals around the prediction of fuel viscosity based on its component mole fractions and viscosities. At -40°C, when all identified components are pure molecules the modeling error is 13.2% of the predicted (nominal) viscosity times the root mean square of the component mole fractions.

10 SYNTHETIC FUELS↗

SUPERMASSIVE BLACK HOLES AND THEIR HOST SPHEROIDS. I. DISASSEMBLING GALAXIES

Several recent studies have performed galaxy decompositions to investigate correlations between the black hole mass and various properties of the host spheroid, but they have not converged on the same conclusions. This is because their models for the same galaxy were often significantly different and not consistent with each other in terms of fitted components. Using 3.6 μm Spitzer imagery, which is a superb tracer of the stellar mass (superior to the K band), we have performed state-of-the-art multicomponent decompositions for 66 galaxies with directly measured black hole masses. Our sample is the largest to date and, unlike previous studies, contains a large number (17) of spiral galaxies with low black hole masses. We paid careful attention to the image mosaicking, sky subtraction, and masking of contaminating sources. After a scrupulous inspection of the galaxy photometry (through isophotal analysis and unsharp masking) and—for the first time—2D kinematics, we were able to account for spheroids; large-scale, intermediate-scale, and nuclear disks; bars; rings; spiral arms; halos; extended or unresolved nuclear sources; and partially depleted cores. For each individual galaxy, we compared our best-fit model with previous studies, explained the discrepancies, and identified the optimal decomposition. Moreover, we have independently performed one-dimensional (1D) and two-dimensional (2D) decompositions and concluded that, at least when modeling large, nearby galaxies, 1D techniques have more advantages than 2D techniques. Finally, we developed a prescription to estimate the uncertainties on the 1D best-fit parameters for the 66 spheroids that takes into account systematic errors, unlike popular 2D codes that only consider statistical errors.

79 ASTRONOMY AND ASTROPHYSICS↗

Holographic dark energy in a universe with spatial curvature and massive neutrinos: a full Markov Chain Monte Carlo exploration

In this paper, we report the results of constraining the holographic dark energy model with spatial curvature and massive neutrinos, based on a Markov Chain Monte Carlo global fit technique. The cosmic observational data include the full WMAP 7-yr temperature and polarization data, the type Ia supernova data from Union2.1 sample, the baryon acoustic oscillation data from SDSS DR7 and WiggleZ Dark Energy Survey, and the latest measurements of H{sub 0} from HST. To deal with the perturbations of dark energy, we adopt the parameterized post-Friedmann method. We find that, for the simplest holographic dark energy model without spatial curvature and massive neutrinos, the phenomenological parameter c < 1 at more than 4σ confidence level. The inclusion of spatial curvature enlarges the error bars and leads to c < 1 only in about 2.5σ range; in contrast, the inclusion of massive neutrinos does not have significant influence on c. We also find that, for the holographic dark energy model with spatial curvature but without massive neutrinos, the 3σ error bars of the current fractional curvature density Ω{sub k0} are still in order of 10{sup −2}; for the model with massive neutrinos but without spatial curvature, the 2σ upper bound of the total mass of neutrinos is Σm{sub ν} < 0.48 eV. Moreover, there exists clear degeneracy between spatial curvature and massive neutrinos in the holographic dark energy model, which enlarges the upper bound of Σm{sub ν} by more than 2 times. In addition, we demonstrate that, making use of the full WMAP data can give better constraints on the holographic dark energy model, compared with the case using the WMAP ''distance priors''.

79 ASTRONOMY AND ASTROPHYSICS↗

Convergence of the Critical Cooling Rate for Protoplanetary Disk Fragmentation Achieved: The Key Role of Numerical Dissipation of Angular Momentum

We carry out simulations of gravitationally unstable disks using smoothed particle hydrodynamics (SPH) and the novel Lagrangian meshless finite mass (MFM) scheme in the GIZMO code. Our aim is to understand the cause of the nonconvergence of the cooling boundary for fragmentation reported in the literature. We run SPH simulations with two different artificial viscosity implementations and compare them with MFM, which does not employ any artificial viscosity. With MFM we demonstrate convergence of the critical cooling timescale for fragmentation at β{sub crit}≈3. Nonconvergence persists in SPH codes. We show how the nonconvergence problem is caused by artificial fragmentation triggered by excessive dissipation of angular momentum in domains with large velocity derivatives. With increased resolution, such domains become more prominent. Vorticity lags behind density, due to numerical viscous dissipation in these regions, promoting collapse with longer cooling times. Such effect is shown to be dominant over the competing tendency of artificial viscosity to diminish with increasing resolution. When the initial conditions are first relaxed for several orbits, the flow is more regular, with lower shear and vorticity in nonaxisymmetric regions, aiding convergence. Yet MFM is the only method that converges exactly. Our findings are of general interest, as numerical dissipation via artificial viscosity or advection errors can also occur in grid-based codes. Indeed, for the FARGO code values of β{sub crit} significantly higher than our converged estimate have been reported in the literature. Finally, we discuss implications for giant planet formation via disk instability.

79 ASTRONOMY AND ASTROPHYSICS↗

Effect of MLC leaf position, collimator rotation angle, and gantry rotation angle errors on intensity-modulated radiotherapy plans for nasopharyngeal carcinoma

The purpose of this study was to investigate the effect of multileaf collimator (MLC) leaf position, collimator rotation angle, and accelerator gantry rotation angle errors on intensity-modulated radiotherapy plans for nasopharyngeal carcinoma. To compare dosimetric differences between the simulating plans and the clinical plans with evaluation parameters, 6 patients with nasopharyngeal carcinoma were selected for simulation of systematic and random MLC leaf position errors, collimator rotation angle errors, and accelerator gantry rotation angle errors. There was a high sensitivity to dose distribution for systematic MLC leaf position errors in response to field size. When the systematic MLC position errors were 0.5, 1, and 2 mm, respectively, the maximum values of the mean dose deviation, observed in parotid glands, were 4.63%, 8.69%, and 18.32%, respectively. The dosimetric effect was comparatively small for systematic MLC shift errors. For random MLC errors up to 2 mm and collimator and gantry rotation angle errors up to 0.5°, the dosimetric effect was negligible. We suggest that quality control be regularly conducted for MLC leaves, so as to ensure that systematic MLC leaf position errors are within 0.5 mm. Because the dosimetric effect of 0.5° collimator and gantry rotation angle errors is negligible, it can be concluded that setting a proper threshold for allowed errors of collimator and gantry rotation angle may increase treatment efficacy and reduce treatment time.

61 RADIATION PROTECTION AND DOSIMETRY↗

TU-EF-204-11: Impact of Using Multi-Slice Training Sets On the Performance of a Channelized Hotelling Observer in a Low-Contrast Detection Task in CT

Purpose: To investigate using multiple CT image slices from a single acquisition as independent training images for a channelized Hotelling observer (CHO) model to reduce the number of repeated scans for CHO-based CT image quality assessment. Methods: We applied a previously validated CHO model to detect low contrast disk objects formed from cross-sectional images of three epoxy-resin-based rods (diameters: 3, 5, and 9 mm; length: ∼5cm). The rods were submerged in a 35x 25 cm2 iodine-doped water filled phantom, yielding-15 HU object contrast. The phantom was scanned 100 times with and without the rods present. Scan and reconstruction parameters include: 5 mm slice thickness at 0.5 mm intervals, 120 kV, 480 Quality Reference mAs, and a 128-slice scanner. The CHO’s detectability index was evaluated as a function of factors related to incorporating multi-slice image data: object misalignment along the z-axis, inter-slice pixel correlation, and number of unique slice locations. In each case, the CHO training set was fixed to 100 images. Results: Artificially shifting the object’s center position by as much as 3 pixels in any direction relative to the Gabor channel filters had insignificant impact on object detectability. An inter-slice pixel correlation of >∼0.2 yielded positive bias in the model’s performance. Incorporating multi-slice image data yielded slight negative bias in detectability with increasing number of slices, likely due to physical variations in the objects. However, inclusion of image data from up to 5 slice locations yielded detectability indices within measurement error of the single slice value. Conclusion: For the investigated model and task, incorporating image data from 5 different slice locations of at least 5 mm intervals into the CHO model yielded detectability indices within measurement error of the single slice value. Consequently, this methodology would Result in a 5-fold reduction in number of image acquisitions. This project was supported by National Institutes of Health grants R01 EB017095 and U01 EB017185 from the National Institute of Biomedical Imaging and Bioengineering.

60 APPLIED LIFE SCIENCES↗

Comparison of an electro-optical system and photo-conducting antenna employed as detectors of pulsed terahertz radiation by means of a new method for measuring spectral width

Two detection systems, electro-optical system and photoconducting system, are tested by the method suggested previously for determining the boundaries of broadband terahertz radiation in time-domain spectroscopy. From a series of measurements the error in determining the operation ranges is calculated. The terahertz spectrometer with an electro-optical detector based on a ZnTe (110) crystal of thickness 2 mm has the operation spectral range of 0.059 – 1.092 THz. The detector utilizing an iPCA-21-05-1000-800-h photo-conducting antenna with the same source of signal demonstrates a wider operation band ranging from 0.017 to 1.6 THz. The method developed makes it possible to experimentally compare the parameters of the considered terahertz spectrometers obtained under the same quality of adjustment. (laser applications and other topics in quantum electronics)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Experimental Assessment of Mammalian Lipidome Complexity Using Multimodal 21 T FTICR Mass Spectrometry Imaging

Herein, we assess the complementarity and complexity of data that can be detected within mammalian lipidome mass spectrometry imaging (MSI) via matrix-assisted laser desorption ionization (MALDI) and nanospray desorption electrospray ionization (nano-DESI). We do so by employing 21 T Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS) with absorption mode FT processing in both cases, allowing unmatched mass resolving power per unit time (≥613k at m/z 760, 1.536 s transients). While our results demonstrated that molecular coverage and dynamic range capabilities were greater in MALDI analysis, nano-DESI provided superior mass error, and all annotations for both modes had sub-ppm error. Taken together, these experiments highlight the coverage of 1676 lipids and serve as a functional guide for expected lipidome complexity within nano-DESI-MSI and MALDI-MSI. To further assess the lipidome complexity, mass splits (i.e., the difference in mass between neighboring peaks) within single pixels were collated across all pixels from each respective MSI experiment. The spatial localization of these mass splits was powerful in informing whether the observed mass splits were biological or artificial (e.g., matrix related). Mass splits down to 2.4 mDa were observed (i.e., sodium adduct ambiguity) in each experiment, and both modalities highlighted comparable degrees of lipidome complexity. Further, we highlight the persistence of certain mass splits (e.g., 8.9 mDa; double bond ambiguity) independent of ionization biases. Here, we also evaluate the need for ultrahigh mass resolving power for mass splits ≤4.6 mDa (potassium adduct ambiguity) at m/z > 1000, which may only be resolved by advanced FTICR-MS instrumentation.

21T-FTICR-MS↗

Improvements of Nuclear Data Evaluations for Lead Isotopes in Support of Next Generation Lead-Cooled Fast Systems

The neutron evaluation of the isotopes that comprise natural lead were undertaken as a part of DOE-NEUP Project #19-16739. The goal of the project was to update the neutron cross sections to account for new differential measurements and incorporate the most up-to-date physics. Shortcomings in the lead cross sections was made known by several independent reports. The work performed here repeated the simulation of all the “benchmark” validation systems and concluded that the major issue is the scattering cross sections in the major lead isotopes above 100 keV. Re-evaluation of 206,207,208 Pb included both the resolved resonance region and fast region evaluations of the cross sections. Combined these regions cover energies from thermal to 20 MeV. The most drastic improvement is the resolved resonance region evaluation of 208 Pb which is now extended from 1.0 to 1.5 MeV. Parameterization of these resonances in the R-matrix provides a superior reconstruction of not only the experimental cross section but also the scattering distributions via the Blatt-Biedenharn formalism. Fast region evaluations of the three major isotopes were done to include new inelastic experimental data from the neutron Time-of-Flight facility at CERN. The culmination of all the changes to the cross section is a drastic improvement in the scattering kernel as shown in Rensselaer Polytechnic Institute (RPI) Quasi-Differential scattering measurements and improved prediction of keff for fast integral experiments. Alongside the new cross sections, new nuclear data covariance (uncertainties) have been computed and are included in the evaluation. Little is changed in the magnitude of the uncertainties but the correlations within the covariance display non-trivial changes. The new evaluations of 206,207,208 Pb have been submitted to the National Nuclear Data Center to be included in the ENDF/B-VIII.1 library. While the cross sections have been updated extensively, knowledge and modeling of the cross sections between 1.0 and 3.0 MeV for the isotopes remain a challenge. Most notably is the double differential elastic cross section for 208 Pb and 206 Pb. New quasi-differential measurements for pure samples of these two nuclei would go a long way in reducing compensating errors in the evaluations. Qualitatively, the project has produced a prosperous collaboration between the nuclear data group at RPI with staff scientists at Brookhaven National Laboratory, Naval Nuclear Laboratory, Oak Ridge National Laboratory, Los Alamos National Laboratory, Lawrence Livermore National Laboratory, and Sandia National Laboratories. Quantitatively this is reflected in seven conference presentations, at least one journal submission, and one doctoral thesis.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Using OSSEs to Evaluate the Impacts of Geostationary Infrared Sounders

An observing system simulation experiment (OSSE) was performed to assess the impact of assimilating hyperspectral infrared (IR) radiances from geostationary orbit on numerical weather prediction, with a focus on the proposed sounder on board the Geostationary Extended Observations (GeoXO) program’s central satellite. Infrared sounders on a geostationary platform would fill several gaps left by IR sounders on polar-orbiting satellites, and the increased temporal resolution would allow the observation of weather phenomena evolution. The framework for this OSSE was the Global Modeling and Assimilation Office (GMAO) OSSE system, which includes a full suite of meteorological observations. The experiment additionally assimilated four identical IR sounders from geostationary orbit to create a “ring” of vertical profiling observations. Based on the experimentation, assimilation of the IR sounders provided a beneficial impact on the analyzed mass and wind fields, particularly in the tropics, and produced an error reduction in the initial 24–48 h of the subsequent forecasts. Specific attention was paid to the impact of the GeoXO Sounder (GXS) over the contiguous United States (CONUS) as this is a region that is well-observed and as such difficult to improve. The forecast sensitivity to observation impact (FSOI) metric, computed across all four synoptic times over the CONUS, reveals that the GXS had the largest impact on the 24-h forecast error of the assimilated hyperspectral infrared satellite radiances as measured using a moist energy error norm. Based on this analysis, the proposed GXS has the potential to improve numerical weather prediction globally and over the CONUS.

OSSE↗

A Review of the Proposed K (sub Isi) Offset-Secant Method for Size-Independent Linear-Elastic Toughness Evaluation

The proposed size-independent linear-elastic fracture toughness, K (sub Isi), for potential inclusion in ASTM E399 targets a consistent 0.5 millimeters crack extension for all specimen sizes through an offset secant that is a function of the specimen ligament length. The K (sub Isi) method also includes an increase in allowable deformation, and the removal of the P (sub max)/P (sub Q) criterion. A finite element study of the K (sub Isi) test method confirms the viability of the increased deformation limit, but has also revealed a few areas of concern. Findings: 1. The deformation limit, b (sub o) greater than or equal to 1.1 times (K (sub I) divided by delta (sub ys) squared) maintains a K-dominant crack tip field with limited plastic contribution to the fracture energy; 2. The three dimensional effects on compliance and the shape of the force versus CMOD (Crack-Mouth Opening Displacement) trace are significant compared to a plane strain assumption; 3. The non-linearity in the force versus CMOD trace at deformations higher than the current limit of 2.5 times (K (sub I) divided by delta (sub ys) squared) is sufficient to introduce error or even "false calls" regarding crack extension when using a constant offset secant line. This issue is more significant for specimens with W (width) greater than or equal to 2 inches; 4. A non-linear plasticity correction factor in the offset secant may improve the viability of the method at deformations between 2.5 times (K (sub I) divided by delta (sub ys) squared) and 1.1 times (K (sub I) divided by delta (sub ys) squared).

James, Mark↗

Individualized empirical baselines for evaluating the energy performance of existing buildings

The evaluation of building energy performance requires a baseline for comparison. Common empirical baselines are usually used for existing buildings since they are fast and convenient. However, the same type of building at the same location will receive the same baseline despite their difference in usage. Individualized baselines by creating building energy models are possible solutions, but it is labor intensive and time-consuming. To fill the gap, this study is to develop individualized empirical baselines for existing buildings in a fast way. First, common empirical baselines are created based on survey data. Then, to get training samples, building energy models for large-scale existing buildings are created and simulated. So finally, based on simulation results, mathematical models to get individualized empirical baselines in a fast way are created. U.S. medium office buildings were used as an example to demonstrate the method. We developed 30 mathematical models for medium office buildings in two vintages (constructed before 1980 and after 1980) and 15 climate zones. The mean absolute percentage errors (MAPE) between the individualized empirical baselines and the modeled baselines for those 30 mathematical models are all lower than 5.5%. An engineer can obtain the individualized empirical baseline for an existing building in a few seconds by using the open-source tool we developed.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Approximate Quantum Codes From Long Wormholes

We discuss families of approximate quantum error correcting codes which arise as the nearly-degenerate ground states of certain quantum many-body Hamiltonians composed of non-commuting terms. For exact codes, the conditions for error correction can be formulated in terms of the vanishing of a two-sided mutual information in a low-temperature thermofield double state. We consider a notion of distance for approximate codes obtained by demanding that this mutual information instead be small, and we evaluate this mutual information for the SYK model and for a family of low-rank SYK models. After an extrapolation to nearly zero temperature, we find that both kinds of models produce fermionic codes with constant rate as the number, N , of fermions goes to infinity. For SYK, the distance scales as N 1 / 2 , and for low-rank SYK, the distance can be arbitrarily close to linear scaling, e.g. N .99 , while maintaining a constant rate. We also consider an analog of the no low-energy trivial states property which we dub the no low-energy adiabatically accessible states property and show that these models do have low-energy states that can be prepared adiabatically in a time that does not scale with system size N . We discuss a holographic model of these codes in which the large code distance is a consequence of the emergence of a long wormhole geometry in a simple model of quantum gravity.

Physics↗

DAO's Next Generation Physical-Space/Finite-Volume Data Assimilation System: Formulation and Initial Evaluation

The Physical-space/Finite-volume Data Assimilation System (fvDAS) is the next generation global atmospheric data assimilation system in development at the Data Assimilation Office at NASA's Goddard Space Flight Center. It is based on a new finite-volume general circulation model jointly developed by NASA and NCAR, and on the Physical-Space Statistical Analysis System (PSAS) developed at the DAO. In this talk we will describe the general system formulation, the adaptive quality control and general aspects of the error covariance modeling. The NASA-NCAR GCM is a completely new model which replaces the CEOs GCM used in the previous GEOS-1/2/3 Data Assimilation systems. A particular configuration of adaptive Statistical Quality Control and the Physical-space Statistical Analysis System (PSAS) are currently implemented in DAO's operational Data Assimilation System. However, the unique finite-volume formulation of the NASA-NCAR GCM, combined with the generality of the observation-space formulation of PSAS, provides for a very simple and accurate model-analysis interface. The system assimilates a variety of conventional and satellite observations. In particular, TOVS Level 1B radiances are assimilated using a 1-D variational scheme, both in clear sky and cloudy conditions. Computationally, the fvDAS runs approximately 10 times faster than the operational GEOS-Terra system. We will show that the next-generation fvDAS has much improved observation-minus-6hr forecast (O-F) statistics, as well as 5-day forecast skills. Top of the atmosphere radiation fields are in closer agreement with CERES measurements, with realistic precipitation and moisture fields. We will also show that the finite-volume formulation of the fvDAS produce assimilated fields which are more suitable for driving constituent transport models.

daSilva, A.↗

Limiter-aware adaptive excitation control for hydropower generators with legacy voltage regulation systems

Hydropower units often rely on legacy excitation systems with fixed automatic voltage regulator (AVR) settings, but parameter drift, changing operating conditions, and evolving grid-service demands can degrade terminal-voltage regulation over time. This problem should be addressed because poor voltage regulation affects reactive-power support, system stability, and reliable plant operation, and replacing installed AVR and limiter logic is costly and disruptive in practice. To address this issue, this paper proposes a retrofit-friendly enhancement for hydropower generator excitation systems that combines adaptive tuning of the AVR middle lead–lag branch with a small proportional-integral correction for removing steady bias and slow drift. The adaptive laws are normalized, projection-bounded, and equipped with leakage, while adaptation is enabled only in the middle branch. Thus, the intent of the underexcitation and overexcitation limiters, as well as legacy current and rate limits, remains unchanged. Stability is analyzed under incremental performance assumptions, yielding boundedness and asymptotic tracking in the absence of saturation. The method is evaluated using real operational data from a utility-scale hydropower unit at Rocky Reach Dam, Unit C-8. Compared with the fixed AVR baseline, the proposed method reduces terminal-voltage mean squared error by about 70%, removes long periods of steady-state bias, and improves transient tracking while coexisting with limiter actions. These results show that substantial voltage-control improvement can be achieved on existing hydropower units with minimal integration effort and without replacing the installed AVR structure.

ESST5B model↗

SU-F-T-376: The Efficiency of Calculating Photonuclear Reaction On High-Energy Photon Therapy by Monte Carlo Method

Purpose: Secondary-neutrons having harmful influences to a human body are generated by photonuclear reaction on high-energy photon therapy. Their characteristics are not known in detail since the calculation to evaluate them takes very long time. PHITS(Particle and Heavy Ion Transport code System) Monte Carlo code since versions 2.80 has the new parameter “pnimul” raising the probability of occurring photonuclear reaction forcibly to make the efficiency of calculation. We investigated the optimum value of “pnimul” on high-energy photon therapy. Methods: The geometry of accelerator head based on the specification of a Varian Clinac 21EX was used for PHITS ver. 2.80. The phantom (30 cm * 30 cm * 30 cm) filled the composition defined by ICRU(International Commission on Radiation Units) was placed at source-surface distance 100 cm. We calculated the neutron energy spectra in the surface of ICRU phantom with “pnimal” setting 1, 10, 100, 1000, 10000 and compared the total calculation time and the behavior of photon using PDD(Percentage Depth Dose) and OCR(Off-Center Ratio). Next, the cutoff energy of photon, electron and positron were investigated for the calculation efficiency with 4, 5, 6 and 7 MeV. Results: The calculation total time until the errors of neutron fluence become within 1% decreased as increasing “pnimul”. PDD and OCR showed no differences by the parameter. The calculation time setting the cutoff energy like 4, 5, 6 and 7 MeV decreased as increasing the cutoff energy. However, the errors of photon become within 1% did not decrease by the cutoff energy. Conclusion: The optimum values of “pnimul” and the cutoff energy were investigated on high-energy photon therapy. It is suggest that using the optimum “pnimul” makes the calculation efficiency. The study of the cutoff energy need more investigation.

60 APPLIED LIFE SCIENCES↗