Search NASA⌕ Search

SEARCH · Search NASA

Results for “variability study”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,765 records · Page 98

End-Gas Autoignition Fraction and Flame Propagation Rate in Laser-Ignited Primary Reference Fuel Mixtures at Elevated Temperature and Pressure

Engine knock in spark-ignited (SI) engines is initiated by autoignition and detonation in the unburned gases (i.e., end-gas) upstream of the spark-ignited, propagating, turbulent premixed flame. Knock propensity of fuel/air mixtures is quantified by research octane number (RON), motor octane number (MON), or methane number (MN; for gaseous fuels), which are typically measured using single-cylinder, variable compression ratio research engines. In this study, we demonstrate the ability to evaluate knock propensity of SI fuels via observations of end-gas autoignition (EGAI) in unburned gases upstream of laser-ignited, premixed flames at elevated pressures and temperatures in a rapid compression machine. Stoichiometric primary reference fuel (PRF; n-heptane/isooctane) blends of varying reactivity (50 ≤ PRF ≤ 100) were ignited using an Nd:YAG laser at five discrete temperature and pressure conditions, all in excess of 485 K and 16.75 bar. Laser ignition produced outwardly-propagating, laminar premixed flames. High-speed pressure measurements, paired with high-speed Schlieren imaging, clearly indicated the presence of EGAI. The fraction of the total heat release attributed to EGAI (e.g. EGAI fraction) varied inversely with octane number. EGAI fraction and flame propagation rate were both influenced by the magnitude of convection in the unburned gases upstream of the propagating flame caused by variation in piston timing. Experiments were accompanied by three-dimensional computational modeling with detailed chemical kinetics performed using CONVERGETM. The model results reveal low-temperature heat release and hydrogen peroxide formation in the end-gas upstream of the propagating laminar flame. Low-temperature heat release increases the temperature and degree of chain branching in the end-gas and ultimately leads to EGAI.

End-Gas Autoignition, Engine Knock, Rapid Compress↗

BETO 2021 Peer Review - Analytical Development and Standardization for Biomass-Derived Thermochemical Liquids

This project began in FY14 to address the lack of standard chemical characterization analytical methods for bio-oils. Bio-oils are very complex and present numerous analytical challenges; yet reliable chemical information (quantification of both individual compounds and chemical functional groups) is needed to inform upgrading research and refinery co-processing. In this project, analysis needs are first determined from engaging the bioenergy community. Next, standard methods are developed to meet these needs, and then subsequently validated via inter-laboratory studies. Methods that are successfully validated (< 10% variability) are then shared as Laboratory Analytical Procedures (LAPs), which are free and publicly available. We have been tracking LAP use and have seen sustained usage as evidenced by an average of 500 pages views and 100 downloads per quarter, demonstrating the value of these methods to the bioenergy community. LAP methods that are particularly useful and reliable will be chosen for the next-level of standardization through ASTM. We have recently achieved approval by ASTM for our carbonyl titration method. This method (ASTM E3146) is the first example of an ASTM standard solely focused on the chemical characterization of bio-oils. Work in this project is meeting the analysis needs of the bioenergy community and will ultimately help enable the commoditization of bio-oils.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Impact of Anatomical Fractionation of Corn Stover on Hammer Mill Throughput and Energy Consumption

The goal of this Case Study was to quantify the impacts of variable moisture and ash on hammer mill throughput and energy consumption and on loss of very wet stover that causes failures in the first stage grinder and that are not able to be fed to conversion, as compared to a status quo Base Case system. Also considered was convertible carbohydrate content (minimum total carbohydrate specification), maximum ash content and the delivered feedstock cost impacts of not being able to feed stover that did not meet the total carbohydrate specification to the conversion reactor. Laboratory data on the impacts of moisture content and tissue fraction on throughput and energy consumption in a stage 2 hammer mill were received from FCIC Subtask 5.1: Preprocessing, Corn Stover Preprocessing (Neal Yancey and Sergio Hernandez, INL). Additional air classifier throughput, energy consumption and separation efficiency data were obtained from FCIC Subtask 5.1 (Neal Yancey, INL) for the new air classifier, which has three exit streams (lights, middle and heavies). These data were utilized to develop the necessary response surface equations to perform throughput analysis using discrete event simulation. Because the ash contents and particle sizes had not been analyzed in the laboratory at the time of the model runs, we assumed that the ash distributed proportionally with total mass into the lights and heavies in an air classifier having two exit streams (lights and heavies) and that the lights fraction from the air classifier was not removed.

ash content↗

Dynamically Learning Incentives for Load Control

As electrical generation becomes more distributed and volatile, and loads become more uncertain, controllability of distributed energy resources (DERs), regardless of their ownership status, will be necessary for grid reliability. Grid operators lack direct control over end-users' grid interactions, such as energy usage, but incentives can influence behavior -- for example, an end-user that receives a grid-driven incentive may adjust their consumption or expose relevant control variables in response. A key challenge in studying such incentives is the lack of data about human behavior, which usually motivates strong assumptions, such as distributional assumptions on compliance or rational utility-maximization. In this paper, we propose a general incentive mechanism in the form of a constrained optimization problem -- our approach is distinguished from prior work by modeling human behavior (e.g., reactions to an incentive) as an arbitrary unknown function. We propose feedback-based optimization algorithms to solve this problem that each leverage different amounts of information and/or measurements. We show that each converges to an asymptotically stable incentive with (near)-optimality guarantees given mild assumptions on the problem. Finally, we evaluate our proposed techniques in voltage regulation simulations on standard test beds. We test a variety of settings, including those that break assumptions required for theoretical convergence (e.g., convexity, smoothness) to capture realistic settings. In this evaluation, our proposed algorithms are able to find near-optimal incentives even when the reaction to an incentive is modeled by a theoretically difficult (yet realistic) function.

demand response↗

Polarization Angle Swings in Blazars Detected in the Millimeter-wave with the South Pole Telescope

We present the first systematic search for electric vector position angle (EVPA) swings in the millimeter-wave (mm-wave) emission of blazars, using five years of observations from the South Pole Telescope SPT-3G camera at 95 and 150 GHz, and investigate their connection to gamma-ray flares. Of the 168 bright sources in the ~1500 square degrees SPT-3G Main Field, eight have sufficient polarization signal-to-noise for reliable EVPA measurement, four of which have continuous Fermi LAT gamma-ray detections. We detect EVPA swings in all four gamma-ray-active blazars and in none of the remaining four, consistent with the established connection between EVPA swings and high-energy emission seen at optical wavelengths. The observed swing amplitudes and rotation rates are smaller than those found in optical studies, consistent with mm-wave EVPA variability being slower than at shorter wavelengths. Random walk simulations of the polarization angle using a multi-cell model fail to reproduce both the number, amplitude, and duration of the observed swings, suggesting that this mechanism is insufficient to explain the observed swing population. Analysis of EVPA variability on one-week timescales is consistent with the anti-correlation between polarization degree and EVPA rotation rate previously observed at optical wavelengths. Of the 14 detected swings, eight are within 30 days of a gamma-ray flare. While many individual swing-flare associations are found to have a very low probability of happening by chance, the full ensembles of 95 and 150 GHz swing time lags with respect to gamma-ray flares are found to be consistent with random coincidence.

Simpson, A. [Chicago U., Astron. Astrophys. Ctr.; ↗

Are dark energy models with variable EoS parameter w compatible with the late inhomogeneous Universe?

We study the late-time evolution of the Universe where dark energy (DE) is presented by a barotropic fluid on top of cold dark matter (CDM) . We also take into account the radiation content of the Universe. Here by the late stage of the evolution we refer to the epoch where CDM is already clustered into inhomogeneously distributed discrete structures (galaxies, groups and clusters of galaxies). Under this condition the mechanical approach is an adequate tool to study the Universe deep inside the cell of uniformity. More precisely, we study scalar perturbations of the FLRW metric due to inhomogeneities of CDM as well as fluctuations of radiation and DE. For an arbitrary equation of state for DE we obtain a system of equations for the scalar perturbations within the mechanical approach. First, in the case of a constant DE equation of state parameter w, we demonstrate that our method singles out the cosmological constant as the only viable dark energy candidate. Then, we apply our approach to variable equation of state parameters in the form of three different linear parametrizations of w, e.g., the Chevallier-Polarski-Linder perfect fluid model. We conclude that all these models are incompatible with the theory of scalar perturbations in the late Universe.

79 ASTRONOMY AND ASTROPHYSICS↗

Intra-urban variability of air pollution in Windsor, Ontario-Measurement and modeling for human exposure assessment

There are acknowledged difficulties in epidemiological studies to accurately assign exposure to air pollution for large populations, and large, long-term cohort studies have typically relied upon data from central monitoring stations. This approach has generally been adequate when populations span large areas or diverse cities. However, when the effects of intra-urban differences in exposure are being studied, the use of these existing central sites are likely to be inadequate for representing spatial variability that exists within an urban area. As part of the Border Air Quality Strategy (BAQS), an international agreement between the governments of Canada and the United States, a number of air health effects studies are being undertaken by Health Canada and the US EPA. Health Canada's research largely focuses on the chronic exposure of elementary school children to air pollution. The exposure characterization for this population to a variety of air pollutants has been assessed using land-use regression (LUR) models. This approach has been applied in several cities to nitrogen dioxide (NO{sub 2}), as an assumed traffic exposure marker. However, the models have largely been developed from limited periods of saturation monitoring data and often only represent one or two seasons. Two key questions from these previous efforts, which are examined in this paper, are: If NO{sub 2} is a traffic marker, what other pollutants, potentially traffic related, might it actually represent? How well is the within city spatial variability of NO{sub 2}, and other traffic-related pollutants, characterized by a single saturation monitoring campaign. Input data for the models developed in this paper were obtained across a network of 54 monitoring sites situated across Windsor, Ontario. The pollutants studied were NO{sub 2}, sulfur dioxide (SO{sub 2}) and volatile organic compounds, which were measured in all four seasons by deploying passive samplers for 2-week periods. Correlations among these pollutants were calculated to assess what other pollutants NO{sub 2} might represent, and correlations across seasons for a given pollutant were determined to assess how much the within-city spatial pattern varies with time. LUR models were then developed for NO{sub 2}, SO{sub 2}, benzene, and toluene. A multiple regression model including proximity to the Ambassador Bridge (the main Canada-US border crossing point), and proximity to highways and major roads, predicted NO{sub 2} concentrations with an R{sup 2}=0.77. The SO{sub 2} model predictors included distance to the Ambassador Bridge, dwelling density within 1500 m, and Detroit-based SO{sub 2} emitters within 3000 m resulting in a model with an R{sup 2}=0.69. Benzene and toluene LUR models included traffic predictors as well as point source emitters resulting in R{sup 2}=0.73 and 0.46, respectively. Between season pollutant correlations were all significant although actual concentrations for each site varied by season. This suggests that if one season were to be selected to represent the annual concentrations for a specific site this may lead to a potential under or overestimation in exposure, which could be significant for health research. All pollutants had strong inter-pollutant correlations suggesting that NO{sub 2} could represent SO{sub 2}, benzene, and toluene.

54 ENVIRONMENTAL SCIENCES↗

Opportunities for Demand Response in California Agricultural Irrigation: A Scoping Study

California agricultural irrigation consumes more than ten billion kilowatt hours of electricity annually and has significant potential for contributing to a reduction of stress on the grid through demand response, permanent load shifting, and energy efficiency measures. To understand this potential, a scoping study was initiated for the purpose of determining the associated opportunities, potential, and adoption challenges in California agricultural irrigation. The primary research for this study was conducted in two ways. First, data was gathered and parsed from published sources that shed light on where the best opportunities for load shifting and demand response lie within the agricultural irrigation sector. Secondly, a small limited survey was conducted as informal face-to-face interviews with several different California growers to get an idea of their ability and willingness to participate in permanent load shifting and/or demand response programs. Analysis of the data obtained from published sources and the survey reveal demand response and permanent load shifting opportunities by growing region, irrigation source, irrigation method, grower size, and utility coverage. The study examines some solutions for demand response and permanent load shifting in agricultural irrigation, which include adequate irrigation system capacity, automatic controls, variable frequency drives, and the contribution from energy efficiency measures. The study further examines the potential and challenges for grower acceptance of demand response and permanent load shifting in California agricultural irrigation. As part of the examination, the study considers to what extent permanent load shifting, which is already somewhat accepted within the agricultural sector, mitigates the need or benefit of demand response for agricultural irrigation. Recommendations for further study include studies on how to gain grower acceptance of demand response as well as other related studies such as conducting a more comprehensive survey of California growers.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Design and Operation of Energy Systems with Large Amounts of Variable Generation: IEA Wind TCP Task 25 (Final Summary Report)

This report summarizes findings on wind integration from the 17 countries or sponsors participating in the International Energy Agency Wind Technology Collaboration Program (IEA Wind TCP) Task 25 from 2006-2020. Both real experience and studies are reported. Many wind integration studies incorporate solar energy, and most of the results discussed here are valid for other variable renewables in addition to wind. The national case studies address several impacts of wind power on electric power systems. In this report, they are grouped under long-term planning issues and short-term operational impacts. Long-term planning issues include grid planning and capacity adequacy. Short-term operational impacts include reliability, stability, reserves, and maximizing the value of wind in operational timescales (balancing related issues). The first section presents the variability and uncertainty of power system-wide wind power, and the last section presents recent studies toward 100% shares of renewables. The appendix provides a summary of ongoing research in the national projects contributing to Task 25 for 2021-2024. The design and operation of power and energy systems is an evolving field. As ambitious targets toward net-zero carbon energy systems are announced globally, many scenarios are being made regarding how to reach these future decarbonized energy systems, most of them involving large amounts of variable renewables, mainly wind and solar energy. The secure operation of power systems is increasingly challenging, and the impacts of variable renewables, new electrification loads together with increased distribution system resources will lead to somewhat different challenges for different systems. Tools and methods to study future power and energy systems also need to evolve, and both short-term operational aspects (such as power system stability) and long-term aspects (such as resource adequacy) will probably see new paradigms of operation and design. The experience of operating and planning systems with large amounts of variable generation is accumulating, and research to tackle the challenges of inverter-based, nonsynchronous generation is on the way. Energy transition and digitalization also bring new flexibility opportunities, both short and long term.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Enhancing the Representation of Subgrid Land Surface Characteristics in Land Surface Models

Land surface heterogeneity has long been recognized and increasingly incorporated in the land surface modelling. In most existing land surface models, the spatial variability of surface cover is represented as subgrid composition of multiple surface cover types. In this study, we developed a new subgrid classification method (SGC) that accounts for the topographic variability of the vegetation cover. Each model grid cell was represented with a number of elevation classes and each elevation class was further described by a number of vegetation types. The numbers of elevation classes and vegetation types were variable and optimized for each model grid so that the spatial variability of both elevation and vegetation can be reasonably explained given a pre-determined total number of classes. The subgrid structure of the Community Land Model (CLM) was used as an example to illustrate the newly developed method in this study. With similar computational burden as the current subgrid vegetation representation in CLM, the new method is able to explain at least 80% of the total subgrid PFTs and greatly reduced the variations of elevation within each subgrid class compared to the baseline method where a single elevation class is assigned to each subgrid PFT. The new method was also evaluated against two other subgrid methods (SGC1 and SGC2) that assigned fixed numbers of elevation and vegetation classes for each model grid with different perspectives of surface cover classification. Implemented at five model resolutions (0.1°, 0.25°, 0.5°, 1.0° and 2.0°) with three maximum-allowed total number of classes N_class of 24, 18 and 12 representing different computational burdens over the North America (NA) continent, the new method showed variable performances compared to the SGC1 and SGC2 methods. However, the advantage of the SGC method over the other two methods clearly emerged at coarser model resolutions and with moderate computational intensity (N_class = 18) as it explained the most PFTs and elevation variability among the three subgrid methods. Spatially, the SGC method explained more elevation variability in topography-complex areas and more vegetation variability in flat areas. Furthermore, the variability of both elevation and vegetation explained by the new method was more spatially homogeneous regardless of the model resolutions and computational burdens. The SGC method will be implemented in CLM over the NA continent to assess its impacts on simulating land surface processes.

characteristics↗

Coupling fast fluid dynamics and multizone airflow models in Modelica Buildings library to simulate the dynamics of HVAC systems

Multizone models are widely used in building airflow and energy performance simulations due to their fast computing speed. However, multizone models assume that the air in a room is well mixed, consequently limiting their application. In specific rooms where this assumption fails, the use of computational fluid dynamics (CFD) models may be an alternative option. Previous research has mainly focused on coupling CFD models and multizone models to study airflow in large spaces. While significant, most of these analyses did not consider the coupled simulation of the building airflow with the building’s Heating, Ventilation, and Air-Conditioning (HVAC) systems. This paper tries to fill the gap by integrating the models for HVAC systems with coupled multizone and CFD simulations for airflows, using the Modelica simulation platform. To improve the computational efficiency, we incorporated a simplified CFD model named fast fluid dynamics (FFD). We first introduce the data synchronization strategy and implementation in Modelica. Then, we verify the implementation using two case studies involving an isothermal and a non-isothermal flow by comparing model simulations to experiment data. Afterward, we study another three cases that are deemed more realistic. Furthermore, this is done by attaching a variable air volume (VAV) terminal box and a VAV system to previous flows to assess the capability of the models in studying the dynamic control of HVAC systems. Finally, we discuss further research needs on the coupled simulation using the models.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Quantum Monte Carlo with variable spins: Fixed-phase and fixed-node approximations

We study several aspects of the recently introduced fixed-phase spinor diffusion Monte Carlo method, in particular, its relation to the fixed-node method and its potential use as a general approach for electronic structure calculations. We illustrate constructions of spinor-based wave functions with the full space-spin symmetry without assigning up or down spin labels to particular electrons, effectively “complexifying” even ordinary real-valued wave functions for Hamiltonians without spin terms. Interestingly, with proper choice of the simulation parameters and spin variables, such fixed-phase calculations enable one to reach also the fixed-node limit. The fixed-phase approximation has several desirable properties when compared to the fixed-node approximation. The fixed-phase solution provides a straightforward interpretation as the lowest bosonic state in a given effective potential generated by the many-body approximate phase, whereas nodal boundary conditions are defined through less intuitive and complicated hypersurfaces with one dimension less than the original configuration space. In addition, the divergences of the local energy and drift at real wave function nodes are smoothed out to lower dimensionality when the wave function is complexified, thus decreasing the variation of sampled quantities and eliminating artificial nodal domain issues that can occur in the fixed-node formalism. We illustrate some of these properties on calculations of selected first-row systems that recover the fixed-node results with quantitatively similar levels of the corresponding biases. At the same time, the fixed-phase approach opens new possibilities for more general trial wave functions with further opportunities for increasing accuracy in practical calculations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Development of the Contamination Distribution Centered Toxics Mobility Vulnerability Index in the Beaumont–Port Arthur Region of Texas

This study advances the Toxics Mobility Inventory (TMI) and the Toxics Mobility Vulnerability Index (TMVI) to develop a new tool to assess the movement of hazardous substances and their implications for vulnerable communities. It emphasizes the need to include contamination distribution variables in such indices to address disproportionate impacts and more accurately reflect vulnerability. The study uses the TMI framework and TMVI methodology in the Beaumont–Port Arthur region of Texas, also integrating contamination distribution considerations into the analysis to develop a new framework and process. The new Contamination Distribution Centered Toxics Mobility Vulnerability Index (CDC-TMVI) consolidates climate change and topography variables into a broader built environment vulnerability category while introducing a contamination sources category. Using ArcGIS Pro and ToxPi tools, the study evaluates 27 geospatial variables across four categories: built environment vulnerability, social vulnerability, health outcomes, and contamination sources. The results indicate significant contributions from contamination and social vulnerability variables, highlighting areas with higher risks of flooding and air pollution. This article advocates for future research and policy efforts to enhance the integration of contamination sources and their spatial distributions into toxics mobility assessments to better protect vulnerable populations. Furthermore, the unique methodology and findings serve as a basis for developing targeted measures and strategic planning to improve environmental health.

contamination↗

Use of Electrical Imaging and Distributed Temperature Sensing Methods to Characterize Surface Water-Groundwater Exchange Regulating Uranium Transport at the Hanford 300 Area, Washington

A critical challenge in advancing prediction of solute transport between contaminated aquifers and rivers is improving understanding of how fluctuations in river stage, combined with subsurface heterogeneity, impart spatiotemporal complexity to solute exchange along river corridors. Here, we explored the use of waterborne geoelectrical imaging, in conjunction with fiber-optic distributed temperature sensor (DTS) monitoring, to improve the conceptual model for uranium transport within the hyporheic corridor at the Hanford 300 Area. We first inverted waterborne geoelectrical (resistivity and induced polarization) datasets for distributions of electrical resistivity and polarizability, from which the spatial complexity of the primary hydrogeologic units was reconstructed. Variations in the depth to the interface between the overlying coarse-grained, high permeability Hanford formation and the underlying finer-grained, less permeable Ringold formation, an important contact that limits vertical migration of contaminants, were resolved along ~3 km of the river corridor centered on the 300 Area. Polarizability images were translated into lithologic images using established relationships between polarizability and surface area normalized to pore volume (Spor). The spatial variability captured in the geoelectrical datasets indicates that previous studies based on borehole projections and point probing overestimate the contributing area for uranium exchange within the Columbia River at the Hanford 300 Area. The DTS data recorded on 1. 5 km of cable with a 1 m spatial resolution and 5 minute sampling interval revealed sub-reaches showing (1) high temperature anomalies and, (2) a strong negative correlation between temperature and river stage, both indicative of groundwater influxes during winter months. The DTS datasets confirm the hydrologic significance of the variability identified in the geoelectrical imaging and reveal a pattern of highly focused hyporheic exchange, with exchange concentrated at springs where the Hanford formation is thick, and coinciding with a paleochannel identified in ground penetrating radar surveys at one location. No evidence for focused hyporheic exchange is observed in the DTS data where the Ringold unit is in contact with the riverbed. Our findings illustrate how the combination of waterborne geoelectrical imaging and DTS technologies can characterize hyporheic exchange in a complex, coupled river-aquifer system.

300 area↗

Development of Building Design Optimization Methodology: Residential Building Applications

Building design optimization is a highly complex problem, requiring long computational running processes because of the many options that exist when a building is being designed. This paper introduces an integrated approach through which to perform this optimization within an acceptable time frame. The approach includes the methods of variable selection, model simplification, and a sequential optimization process. Using singular value decomposition, a large number of design variables is reduced to a smaller subset that can be solved more quickly through the optimization algorithm. To expedite the variable selection process, a modeling approach that quickly simulates annual energy consumption was developed to replace full annual energy simulations. The developed methodology was applied to two residential buildings in the US, and the results are discussed herein. To assess the accuracy of the integrated optimization methodology, the optimized life cycle costs are compaa variables demonstrating the strongest contributions in the optimization study were identified. The proposed methodology significantly shortened the time requirements for the optimization processes of the two case studies by 74% and 84%; the optimized life cycle costs were within 0.05% and 0.06%, respectively, of the optimum point.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Near-Surface Hydrology and Soil Properties Drive Heterogeneity in Permafrost Distribution, Vegetation Dynamics, and Carbon Cycling in a Sub-Arctic Watershed: Modeling Archive

This Modeling Archive is in support of a NGEE-Arctic publication: Shirley et al. (2022) “Near-Surface Hydrology and Soil Properties Drive Heterogeneity in Permafrost Distribution, Vegetation Dynamics, and Carbon Cycling in a Sub-Arctic Watershed". [DOI].The dataset contains outputs from the global sensitivity analysis (GSA) of the “ecosys” model as reported in Shirley et al. (2022). The study showed that discontinuous permafrost environments are characterized by complex feedback loops and strong spatial heterogeneity which is created by variability in near-surface hydrology and soil properties. Additionally, the study demonstrated that missing representation of sub-grid heterogeneity in terrestrial ecosystem models can lead to biased estimates of the high-latitude carbon budget. Included in this dataset are the factor values for each run in the GSA and the model outputs used in this study. Included are two *.csv data files and one *.pdf.The Next-Generation Ecosystem Experiments: Arctic (NGEE Arctic), was a research effort to reduce uncertainty in Earth System Models by developing a predictive understanding of carbon-rich Arctic ecosystems and feedbacks to climate. NGEE Arctic was supported by the Department of Energy's Office of Biological and Environmental Research.The NGEE Arctic project had two field research sites: 1) located within the Arctic polygonal tundra coastal region on the Barrow Environmental Observatory (BEO) and the North Slope near Utqiagvik (Barrow), Alaska and 2) multiple areas on the discontinuous permafrost region of the Seward Peninsula north of Nome, Alaska.Through observations, experiments, and synthesis with existing datasets, NGEE Arctic provided an enhanced knowledge base for multi-scale modeling and contributed to improved process representation at global pan-Arctic scales within the Department of Energy's Earth system Model (the Energy Exascale Earth System Model, or E3SM), and specifically within the E3SM Land Model component (ELM).

54 ENVIRONMENTAL SCIENCES↗

Continuous variable port-based teleportation

Abstract Port-based teleportation (PBT) is a generalisation of the standard teleportation protocol which does not require unitary operations by the receiver. This comes at the price of requiring N > 1 entangled pairs, while N = 1 for the standard teleportation protocol. The lack of correction unitaries allows PBT to be used as a fundamental theoretical tool to simulate arbitrary channels with a general resource, with applications to study fundamental limits of quantum communication, cryptography and sensing, and to define general programmable quantum computers. Here we introduce a general formulation of port-based teleportation in continuous variable systems and study in detail the N = 2 case. In particular, we interpret the resulting channel as an energy truncation and analyse the kinds of channels that can be naturally simulated after this restriction.

97 MATHEMATICS AND COMPUTING↗