Search NASA⌕ Search

SEARCH · Search NASA

Results for “variational method”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,765 records · Page 98

Adaptive Quantum Generative Training using an Unbounded Loss Function

We propose a generative quantum learning algorithm using the Adaptive Derivative-Assembled Problem Tailored ansatz (ADAPT) framework in which the loss function to be minimized is the maximal quantum Rényi divergence of order two, an unbounded function that mitigates barren plateaus which inhibit training variational circuits. We benchmark this method against other state-of-the-art adaptive algorithms by learning random two-local thermal states. We perform numerical experiments of up to 12 qubits comparing our method learning algorithms that use linear objective functions and show that Rényi-ADAPT is capable of constructing shallow quantum circuits competitive with existing methods, while the gradients remain favorable resulting from the maximal Rényi divergence loss function.

quantum algorithms, quantum machine learning, quan↗

An Information Theoretic Approach to Identify Dominant Voltage Influencers for Unbalanced Distribution Systems

Smart distribution grid with multiple renewable energy sources can experience random voltage fluctuations due to variable generation, which may result in voltage violations. Traditional voltage control algorithms are inadequate to handle fast voltage variations. Therefore, new dynamic control methods are being developed that can significantly benefit from the knowledge of dominant voltage influencer (DVI) nodes. DVI nodes for a particular node of interest refer to nodes that have a relatively high impact on the voltage fluctuations at that node. Conventional power flow-based algorithms to identify DVI nodes are computationally complex, which limits their use in real-time applications. This paper proposes a novel information theoretic voltage influencing score (VIS) that quantifies the voltage influencing capacity of nodes with DERs/active loads in a three phase unbalanced distribution system. VIS is then employed to rank the nodes and identify the DVI set. VIS is derived analytically in a computationally efficient manner and its efficacy to identify DVI nodes is validated using the IEEE 37-node test system. It is shown through experiments that KL divergence and Bhattacharyya distance are effective indicators of DVI nodes with an identifying accuracy of more than 90%. Additionally, the computation burden is also reduced by an order of 5, thus providing the foundation for efficient voltage control.

42 ENGINEERING↗

Influence of dosing sequence and film thickness on structure and resistivity of Al-ZnO films grown by atomic layer deposition

Aluminum-doped zinc oxide (AZO) films were deposited onto amorphous silica substrates using an atomic layer deposition process with diethyl zinc (DEZ), trimethyl aluminum (TMA), and deionized water at 200 °C. Three different Al doping sequences were used at a ZnO:Al ratio of 11:1 within the films. A minimum film resistivity of 1.6 × 10{sup −3} Ω cm was produced using sequential dosing of DEZ, TMA, DEZ, followed by H{sub 2}O for the Al doping step. This “ZAZW” sequence yielded an AZO film resistivity that is independent of film thickness, crystallographic texture, and grain size, as determined by high resolution x-ray diffraction (XRD). A pseudo-Voigt analysis method yields values for grain sizes that are smaller than those calculated using other XRD methods. Anisotropic grain sizes or variations in crystallographic texture have minimal influence on film resistivity, which suggests that factors other than film texture, such as intragrain scattering, may be important in influencing film resistivity.

36 MATERIALS SCIENCE↗

Novel dosimetric phantom for quality assurance of volumetric modulated arc therapy

The objective of this work is to assess the suitability and performance of a new dosimeter system with a novel geometry for the quality assurance (QA) of volumetric modulated arc therapy (VMAT). The new dosimeter system consists of a hollow cylinder (15 and 25 cm inner and outer diameters) with 124 diodes embedded in the phantom's cylindrical wall forming four rings of detectors. For coplanar beams, the cylindrical geometry and the ring diode pattern offer the advantage of invariant perpendicular incidence on the beam central axis for any gantry angle and also have the benefit of increasing the detector density as both walls of the cylinder sample the beam. Other advantages include real-time readout and reduced weight with the hollow phantom shape. A calibration method taking into account the variation in radiation sensitivity of the diodes as a function of gantry angle was developed and implemented. In this work, the new dosimeter system was used in integrating mode to perform composite dose measurements along the cylindrical surface supporting the diodes. The reproducibility of the dosimeter response and the angular dependence of the diodes were assessed using simple 6 MV photon static beams. The performance of the new dosimeter system for VMAT QA was then evaluated using VMAT plans designed for a head and neck, an abdominal sarcoma, and a prostate patient. These plans were optimized with 90 control points (CPs) and additional versions of each plan were generated by increasing the number of CPs to 180 and 360 using linear interpolation. The relative dose measured with the dosimeter system for the VMAT plans was compared to the corresponding TPS dose map in terms of relative dose difference (%{Delta}D) and distance to agreement (DTA). The dosimeter system's sensitivity to gantry rotation offset and scaling errors as well as setup errors was also evaluated. For static beams, the dosimeter system offered good reproducibility and demonstrated small residual diode angular dependence after calibration. For VMAT deliveries, the agreement between measured and calculated doses was good with {>=}86.4% of the diodes satisfying 3% of %{Delta}D or 2 mm DTA for the 180 CP plans. The phantom offered sufficient sensitivity for the detection of small gantry rotation offset (3 deg.) and scaling errors (1 deg.) as well as phantom setup errors of 1 mm, although the results were plan dependent. With its novel geometry, the dosimeter system was also able to experimentally demonstrate the discretization effect of the number of CPs used in the TPS to simulate a continuous arc. These results demonstrate the suitability of the new dosimeter system for the patient-specific QA of VMAT plans and suggest that the dosimeter system can be an effective tool in the routine QA and commissioning of treatment machines capable of VMAT delivery and cone-beam CT image guidance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-I-14: Comparison of Iodine-Labeled and Indium-Labeled Antibody Biodistributions

Purpose: It is often assumed that animal biodistributions of novel proteins are not dependent upon the radiolabel used in their determination. In units of percent injected dose per gram of tissue (%ID/g), organ uptake results (u) may be obtained using either iodine or metal as radioactive labels. Iodination is preferred as it is a one-step process whereas metal labeling requires two chemical procedures and therefore more protein material. It is important to test whether the radioactive tag leads to variation in the uptake value. Methods: Uptakes of 3antibodies to Carcinoembryonic Antigen (CEA) were evaluated in a nude mouse model bearing 150 to 300 mg LS174T human colon cancer xenografts. Antibodies included diabody (56 kDa), minibody (80kDa) and intact M5A (150 kDa) anti-CEA cognates. Both radioiodine and indium-111 labels were used with uptakes evaluated at 7 time(t) points out to 96 h. Ratios (R) of u(iodine-label)/u(indium-label) were determined for liver, spleen, kidneys, lung and tumor. Results: Hepatic loss was rapid for diabody and minibody; by 24 h their R values were only 2%; i.e., uptake of iodine was 2% of that of indium for these 2 antibodies. By contrast, R for the intact cognate was 50% at that time point. Splenic results were similar. Tumor uptake ratios did not depend upon the antibody type and were 50% at 24 h. Conclusions: Relatively rapid loss of iodine relative to indium in liver and spleen was observed in lower mass antibodies. Tumor ratios were larger and independent of antibody type. Aside from tumor, the R ratio of uptakes depended on the antibody type. R values decreased monotonically with time in all tissues and for all cognates. Using this ratio, one can possibly correct iodine-based u (t) results so that they resemble radiometal-derived biodistributions.

60 APPLIED LIFE SCIENCES↗

MO-A-BRD-02: Noise Suppression for Dual-Energy CT Through Entropy Minimization

Purpose: In dual energy CT (DECT), noise amplification during signal decomposition significantly limits the utility of basis material images. Since clinically relevant objects contain a limited number of materials, we propose to suppress noise in decomposed images through entropy minimization within a 2D transformation space. Distinct from other noise suppression techniques, the entropy minimization method does not estimate and suppress noise based on spatial variations of signals and thus maximally preserves image spatial resolution. Methods: From decomposed images, we first generate a 2D plot of scattered data points, using basis material densities as coordinates. Data points representing the same material generate a cluster with a highly asymmetric shape. We orient an axis by minimizing the entropy in a 1D histogram of these points projected onto the axis. To suppress noise, we replace the pixel values of decomposed images with center-of-mass values in the direction perpendicular to the optimized axis. The proposed method's performance is assessed using a Catphan 600 phantom and an anthropomorphic head phantom. Electron density calculations are used to quantify its accuracy. Our results are compared to those without noise suppression, with a filtering method, and with a recently developed iterative method. Results: On both phantoms, the proposed method reduces noise standard deviations of the decomposed images by at least on order of magnitude. In the Catphan study, this method retains the spatial resolution of the CT images and increases the accuracy of electron density calculations. In the head phantom study, the proposed method outperforms the others in retaining fine, intricate structures. Conclusion: This work shows that the proposed method of noise suppression through entropy minimization for DECT suppresses noise without loss of spatial resolution while increasing electron density calculation accuracy. Future investigations will analyze possible bias and incorporate spatial information into the technique for further noise reduction. The work is partially supported by the NIH under the grant number R21EB012700.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation of potential internal target volume of liver tumors using cine-MRI

Purpose: Four-dimensional computed tomography (4DCT) is widely used for evaluating moving tumors, including lung and liver cancers. For patients with unstable respiration, however, the 4DCT may not visualize tumor motion properly. High-speed magnetic resonance imaging (MRI) sequences (cine-MRI) permit direct visualization of respiratory motion of liver tumors without considering radiation dose exposure to patients. Here, the authors demonstrated a technique for evaluating internal target volume (ITV) with consideration of respiratory variation using cine-MRI. Methods: The authors retrospectively evaluated six patients who received stereotactic body radiotherapy (SBRT) to hepatocellular carcinoma. Before acquiring planning CT, sagittal and coronal cine-MRI images were acquired for 30 s with a frame rate of 2 frames/s. The patient immobilization was conducted under the same condition as SBRT. Planning CT images were then acquired within 15 min from cine-MRI image acquisitions, followed by a 4DCT scan. To calculate tumor motion, the motion vectors between two continuous frames of cine-MRI images were calculated for each frame using the pyramidal Lucas–Kanade method. The target contour was delineated on one frame, and each vertex of the contour was shifted and copied onto the following frame using neighboring motion vectors. 3D trajectory data were generated with the centroid of the contours on sagittal and coronal images. To evaluate the accuracy of the tracking method, the motion of clearly visible blood vessel was analyzed with the motion tracking and manual detection techniques. The target volume delineated on the 50% (end-exhale) phase of 4DCT was translated with the trajectory data, and the distribution of the occupancy probability of target volume was calculated as potential ITV (ITV {sub Potential}). The concordance between ITV {sub Potential} and ITV estimated with 4DCT (ITV {sub 4DCT}) was evaluated using the Dice’s similarity coefficient (DSC). Results: The distance between blood vessel positions determined with motion tracking and manual detection was analyzed. The mean and SD of the distance were less than 0.80 and 0.52 mm, respectively. The maximum ranges of tumor motion on cine-MRI were 2.4 ± 1.4 mm (range, 1.0–5.0 mm), 4.4 ± 3.3 mm (range, 0.8–9.4 mm), and 14.7 ± 5.9 mm (range, 7.4–23.4 mm) in lateral, anterior–posterior, and superior–inferior directions, respectively. The ranges in the superior–inferior direction were larger than those estimated with 4DCT images for all patients. The volume of ITV {sub Potential} was 160.3% ± 13.5% (range, 142.0%–179.2%) of the ITV {sub 4DCT}. The maximum DSC values were observed when the cutoff value of 24.7% ± 4.0% (range, 20%–29%) was applied. Conclusions: The authors demonstrated a novel method of calculating 3D motion and ITV {sub Potential} of liver cancer using orthogonal cine-MRI. Their method achieved accurate calculation of the respiratory motion of moving structures. Individual evaluation of the ITV {sub Potential} will aid in improving respiration management and treatment planning.

60 APPLIED LIFE SCIENCES↗

Interactive prostate segmentation using atlas-guided semi-supervised learning and adaptive feature selection

Purpose: Accurate prostate segmentation is necessary for maximizing the effectiveness of radiation therapy of prostate cancer. However, manual segmentation from 3D CT images is very time-consuming and often causes large intra- and interobserver variations across clinicians. Many segmentation methods have been proposed to automate this labor-intensive process, but tedious manual editing is still required due to the limited performance. In this paper, the authors propose a new interactive segmentation method that can (1) flexibly generate the editing result with a few scribbles or dots provided by a clinician, (2) fast deliver intermediate results to the clinician, and (3) sequentially correct the segmentations from any type of automatic or interactive segmentation methods. Methods: The authors formulate the editing problem as a semisupervised learning problem which can utilize a priori knowledge of training data and also the valuable information from user interactions. Specifically, from a region of interest near the given user interactions, the appropriate training labels, which are well matched with the user interactions, can be locally searched from a training set. With voting from the selected training labels, both confident prostate and background voxels, as well as unconfident voxels can be estimated. To reflect informative relationship between voxels, location-adaptive features are selected from the confident voxels by using regression forest and Fisher separation criterion. Then, the manifold configuration computed in the derived feature space is enforced into the semisupervised learning algorithm. The labels of unconfident voxels are then predicted by regularizing semisupervised learning algorithm. Results: The proposed interactive segmentation method was applied to correct automatic segmentation results of 30 challenging CT images. The correction was conducted three times with different user interactions performed at different time periods, in order to evaluate both the efficiency and the robustness. The automatic segmentation results with the original average Dice similarity coefficient of 0.78 were improved to 0.865–0.872 after conducting 55–59 interactions by using the proposed method, where each editing procedure took less than 3 s. In addition, the proposed method obtained the most consistent editing results with respect to different user interactions, compared to other methods. Conclusions: The proposed method obtains robust editing results with few interactions for various wrong segmentation cases, by selecting the location-adaptive features and further imposing the manifold regularization. The authors expect the proposed method to largely reduce the laborious burdens of manual editing, as well as both the intra- and interobserver variability across clinicians.

07 ISOTOPE AND RADIATION SOURCES↗

WE-D-303-05: Dosimetric Accuracy of CBCT Images Estimated by a Motion Modeling and Free-Form Deformation Technique for Radiotherapy of Lung Cancer

Purpose: To investigate the dosimetric accuracy of CBCTs estimated by a motion modeling and free-form deformation(MM-FD) technique for radiotherapy of lung cancer. Methods: Various inter-fractional variations featuring patient motion pattern change, tumor size change and tumor average position change were simulated from planning-CT to on-board images using both digital and physical motion phantoms. The doses calculated on the planning-CT (planned doses), the on-board CBCT estimated by MM-FD (MM-FD doses) and the on-board CBCT reconstructed by the conventional Feldkamp-Davis-Kress(FDK) algorithm (FDK doses) were compared to the on-board dose calculated on the ‘gold-standard’ on-board images (gold-standard doses). The absolute deviations of minimum dose (dDmin), maximum dose (dDmax), mean dose (dDmean) and dose coverage (dV100%) of PTV were evaluated. In addition, 4D on-board dose accumulations were performed using the 4D-CBCT images estimated by MM-FD. The accumulated doses were compared to measurements using OSL detectors and radiochromic films. Results: Of all the 50 scenarios simulated, the average(± standard deviation) dDmin, dDmax, dDmean and dV100% (values normalized by the prescription dose or the PTV volume) between the planned and the gold-standard PTV doses were 34.8% (± 29.2%), 3.2% (± 3.8%), 3.5% (± 3.5%) and 13.0% (± 11.4%), respectively. The corresponding values of FDK PTV doses were 3.1% (± 3.7%), 1.4% (± 1.1%), 2.1% (± 0.8%) and 14.5% (± 14.2%), respectively. In contrast, the corresponding values of MM-FD PTV doses were 0.4% (± 0.5%), 0.9% (± 0.7%), 0.6% (± 0.4%) and 0.9% (± 0.8%), respectively.For the 4D dose accumulation study, the average(± standard deviation) absolute dose deviation (normalized by local doses) between the accumulated doses and the OSL measured doses was 3.0% (± 2.4%). The average gamma pass-rate(3%/3mm) between the accumulated doses and the radiochromic film measured doses was 96.1%. Conclusion: MM-FD estimated CBCT enables accurate on-board dose calculation and accumulation for lung radiation therapy. The research was funded by the National Institutes of Health Grant No. R01-CA184173 and a grant from Varian Medical Systems.

60 APPLIED LIFE SCIENCES↗

SSRS (Stochastic Soaring Raptor Simulator)

SSRS (Stochastic Soaring Raptor Simulator) is a generalizable, probabilistic, and predictive tool for wind energy developers, ecologists, wildlife managers and industry consultants to estimate the potential for soaring raptors to interact with operating wind turbines, without the need for site-specific data collection. Rapid expansion of wind energy development across the world has exposed the risk of turbine collisions for birds and bats. The risk to obligate soaring raptors such as golden eagles is of particular concern due to their small population and influence on ecological balance. Golden eagles rely heavily on updrafts to subsidize their flight, putting them in direct conflict with operational wind turbines that utilize the same wind resource. Understanding the behavior of soaring raptors with varying atmospheric conditions is crucial for predicting and mitigating the risk of turbine collision. This software contains a predictive movement model that simulates individual flight paths of golden eagles during updraft-subsidized long-distance flight, including migration. For a given set of atmospheric conditions, the model simulates thousands of eagles at turbine-scale spatial resolution (50m) to produce a relative presence density map. The simulated eagles rely on updrafts to pursue uninterrupted directional flight with minimal energy expenditure, following fluid-flow principles. The simulator includes a stochastic model of eagle behavior and a systematic method of accounting for spatiotemporal variations in atmospheric conditions. This framework only requires publicly available atmospheric data to estimate orographic and thermal updrafts, ensuring general usability.

Sandhu, Rimple↗

Optimization of Uranium Molecular Deposition for Alpha-Counting Sources

Method development for molecular deposition of uranium onto aluminum 1100 plates was conducted with custom plating cells at Lawrence Livermore National Laboratory. The method development focused primarily on variation of electrode type, which was expected to directly influence plated sample homogeneity. Solid disc platinum and mesh platinum anodes were compared and data revealed that solid disc platinum anodes produced more homogenous uranium oxide films. However, the activity distribution also depended on the orientation of the platinum electrode relative to the aluminum cathode, starting current, and material composition of the plating cell. Experiments demonstrated these variables were difficult to control under the conditions available. Variation of plating parameters among a series of ten deposited plates yielded variations up to 30% in deposition efficiency. Teflon particles were observed on samples plated in Teflon cells, which poses a problem for alpha activity measurements of the plates. Preliminary electropolishing and chemical polishing studies were also conducted on the aluminum 1100 cathode plates.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development of Grade 91 inelastic model for incorporation in ASME Division 5

This report describes a unified viscoplastic model for Grade 91 suitable for use with the Section III, Division 5 design by inelastic analysis procedures in the ASME Boiler and Pressure Vessel Code. The report identifies several key features a successful design inelastic model must capture along with critical aspects of the response of Grade 91 for elevated temperature loading conditions typical of expected reactor operating conditions. An inelastic model for Code design must capture the average response of a material including heat-to-heat and product form variations. This work develops a method for calibrating such a model to a large experimental database using genetic algorithm optimization. Finally, the report compares the final model to several specialized experimental tests to validate that it will be suitable for use in high temperature structural design. The techniques developed here can be applied to the remaining Section III, Division 5, Class A materials to develop a nonmandatory appendix to the Code describing inelastic material models suitable for use with the design by inelastic analysis procedures.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Online Monitoring System for Concrete Structures Affected by Alkali-Silica Reaction

This report presents a comprehensive study of developing ultrasonic wave and acoustic emission (AE) techniques for long-term monitoring of alkali-silica reaction (ASR) development in concrete. Small, medium, and full-scale concrete specimens were cast, conditioned, and monitored for various periods, from at least one year to 2.4 years. The reactive concrete specimens contain coarse or fine reactive aggregates to study the effects of different types of reactive aggregates. Confinements were also designed to simulate the 2-dimensional confinement effects of reinforcement in the shield building of nuclear power plants. The concrete specimens were stored in a environmental chamber with high humidity and high temperature to accelerate the ASR development. The ultrasonic monitoring data shows high sensitivity to ASR development and could detect cracking initiation well before visible surface cracks occurred. However, the linear ultrasonic analysis based on wave velocity is strongly affected by temperature variation. Therefore, a nonlinear ultrasonic method was proposed to measure thermally induced nonlinear acoustic responses of concrete (thermal modulation of ultrasonic wave). The measured nonlinear acoustic parameter shows a high correlation with ASR expansion across specimens with different reactive aggregates and confinement conditions. The same conclusion was obtained from nonlinear resonance tests on small concrete prisms. Compared to the linear acoustic methods, the nonlinear tests show high sensitivities to ASR damage from internal microcracking initiation at the early stage to visible cracks at the late stage of ASR. The attributes of the thermal modulation of nonlinear ultrasonic method include high sensitivity, immunity to temperature effects, and strong correlation with ASR expansion, which demonstrate great potentials of the nonlinear ultrasonic method for diagnosis of ASR damage and prediction of concrete deterioration process. Acoustic emission is a passive sensing technique for damage assessment, and access to only one surface is needed even for thick and heavily reinforced elements such as the walls utilized for nuclear shield building. Additionally, relatively few sensors are required to monitor the progression of the damage process. Results indicate that the AE data can be related to the damage rating index, which is a petrography-based means of assessing damage due to ASR in reinforced concrete. Furthermore, AE is capable of detecting ASR damage long before surface cracking is visually noticeable. Boundary conditions play in important role in the progression of ASR damage and differences in boundary conditions are reflected in the AE data. Entropy based data assessment methods provide a means to assess the damage state, and convolutional neural network based data assessment provided a means to assess the damage state in real-time. Results indicate that artificial neural network models may be used as a means to predict volumetric expansion based on AE data.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Lattice calculation of the pion electromagnetic form factor at high momentum transfer

The pion electromagnetic form factor, Fn, is a fundamentally important topic for our understanding of the hadron structure and the transition from perturbative to nonperturbative QCD. JLAB?s experiment E12-06-101 proposes to extend the high quality F? data to Q2=6.0 GeV2 as a part of JLAB?s 12 GeV upgrade. Being motivated by this, we present a lattice QCD calculation of Fn using the method of distillation and the variational approach which significantly reduce the excited state contamination. We study the shape of the vector form factor in the Q2 range from zero to a few GeV2 using Wilson quark formalism on our 203×128 anisotropic lattice configuration with light (up/down) and strange quarks in the sea and 400 MeV pion mass.

Chakraborty, Bipasha↗

Real-Time Krylov Theory for Quantum Computing Algorithms

Quantum computers provide new avenues to access ground and excited state properties of systems otherwise difficult to simulate on classical hardware. New approaches using subspaces generated by real-time evolution have shown efficiency in extracting eigenstate information, but the full capabilities of such approaches are still not understood. In recent work, we developed the variational quantum phase estimation (VQPE) method, a compact and efficient real-time algorithm to extract eigenvalues on quantum hardware. Here we build on that work by theoretically and numerically exploring a generalized Krylov scheme where the Krylov subspace is constructed through a parametrized real-time evolution, which applies to the VQPE algorithm as well as others. We establish an error bound that justifies the fast convergence of our spectral approximation. We also derive how the overlap with high energy eigenstates becomes suppressed from real-time subspace diagonalization and we visualize the process that shows the signature phase cancellations at specific eigenenergies. We investigate various algorithm implementations and consider performance when stochasticity is added to the target Hamiltonian in the form of spectral statistics. To demonstrate the practicality of such real-time evolution, we discuss its application to fundamental problems in quantum computation such as electronic structure predictions for strongly correlated systems.

97 MATHEMATICS AND COMPUTING↗

Investigating the Effects of Chemical Mechanism on Soot Formation Under High-Pressure Fuel Pyrolysis

We performed Computational Fluid Dynamics (CFD) simulations using a Reynolds-Averaged Navier-Stokes (RANS) turbulence model of high-pressure spray pyrolysis with a detailed chemical kinetic mechanism encompassing pyrolysis of n-dodecane and formation of polycyclic aromatic hydrocarbons. We compare the results using the detailed mechanism and those found using several different reduced chemical mechanisms to experiments carried out in an optically accessible, high-pressure, constant-volume combustion chamber. Three different soot models implemented in the CONVERGE CFD software are used: an empirical soot model, a method of moments, and a discrete sectional method. There is a large variation in the prediction of the soot between different combinations of chemical mechanisms and soot model. Furthermore, the amount of soot produced from all models is substantially less than experimental measurements. All of this indicates that there is still substantial work that needs to be done to arrive at simulations that can be relied on to accurately predict soot formation.

02 PETROLEUM↗

Model-independent Exoplanet Transit Spectroscopy

We propose a new data analysis method for obtaining transmission spectra of exoplanet atmospheres and brightness variation across the stellar disk from transit observations. The new method is capable of recovering exoplanet atmosphere absorption spectra and stellar specific intensities without relying on theoretical models of stars and planets. We simultaneously fit both stellar specific intensity and planetary radius directly to transit light curves. This allows stellar models to be removed from the data analysis. Furthermore, we use a data quality weighted filtering technique to achieve an optimal trade-off between spectral resolution and reconstruction fidelity homogenizing the signal-to-noise ratio across the wavelength range. Such an approach is more efficient than conventional data binning onto a low-resolution wavelength grid. We demonstrate that our analysis is capable of reproducing results achieved by using an explicit quadratic limb-darkening equation and that the filtering technique helps eliminate spurious spectral features in regions with strong telluric absorption. The method is applied to the VLT FORS2 observations of the exoplanets GJ 1214 b and WASP-49 b, and our results are in agreement with previous studies. Comparisons between obtained stellar specific intensity and numerical models indicates that the method is capable of accurately reconstructing the specific intensity. The proposed method enables more robust characterization of exoplanetary atmospheres by separating derivation of planetary transmission and stellar specific intensity spectra (that is model-independent) from chemical and physical interpretation.

79 ASTRONOMY AND ASTROPHYSICS↗

Particle Vertical Mixing and Horizontal Conveyance Within an Ambient Temperature Fluidized Bed

Previous studies have shown the advantages of particle-to-sCO2 fluidized bed (FB) heat exchangers, which include high heat transfer coefficients, low material cost, and the ability to horizontally convey solid particles. This paper outlines the design and testing of a compact cold flow FB test apparatus to characterize horizontal conveyance through convolutions within a 100 kWth FB heat exchanger design. Horizontal conveyance is an advantage in FBs because it enables more compact designs for heat exchangers. Two mass flow rates, 0.5 & 1 kg/s, at the inlet & outlet of the FB. To determine consistency of the flow rates, Student’s t-tests were used to assess whether the inlet & outlet values were statistically similar. The mass flow rate exiting the bed was statistically similar to the flow rate entering the bed for both cases, but each case featured a wider range and standard deviation. The range and standard deviation of the 1 kg/s flow rate was 0.69-1.23 kg/s and 0.12 kg/s respectively, and the 0.5 kg/s test featured a range and standard deviation of 0.37-0.73 kg/s and 0.09 kg/s, respectively. These measurements provide confidence that large-scale designs can successfully horizontally convey particles at ````~1.5x minimum fluidization velocity (U­mf) without significant variation in flow rate. A method to characterize the degree of particle vertical mixing and bubble frequency within the FB is also introduced. By using a high-resolution camera together with particle velocimetry, particle motion in the X and Y directions can be estimated to assess bed mixing and bubble frequency.

Khalaf, Jawad↗