Search NASA⌕ Search

SEARCH · Search NASA

Results for “Accelerators, Instrumentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,783 records · Page 99

Digitized detection of gamma-ray signals concentrated in narrow time windows for transient positron annihilation lifetime spectroscopy

A pulsed slow-positron beam generated by an electron linear accelerator was directly used for positron annihilation lifetime spectroscopy without any positron storage devices. A waveform digitizer was introduced to simultaneously capture multiple gamma-ray signals originating from positron annihilation events during a single accelerator pulse. The positron pulse was chopped and bunched with the chopper signals also sent to the waveform digitizer. Time differences between the annihilation gamma-ray and chopper peaks were calculated and accumulated as lifetime spectra in a computer. The developed technique indicated that positron annihilation lifetime spectroscopy can be performed in a 20 μs time window at a pulse repetition rate synchronous with the linear accelerator. Lifetime spectra of a Kapton sheet and a thermally grown SiO{sub 2} layer on Si were successfully measured. Synchronization of positron lifetime measurements with pulsed ion irradiation was demonstrated by this technique.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Gas production in the MEGAPIE spallation target

The Megawatt Pilot Experiment (MEGAPIE) project was started in 2000 to design, build and operate a liquid Lead-Bismuth Eutectic (LBE) spallation neutron target at the power level of 1 MW. The target was irradiated for four months in 2006 at the Paul Scherrer Inst. in Switzerland. Gas samples were extracted in various phases of operation and analyzed by {gamma} spectroscopy leading to the determination of the main radioactive isotopes released from the LBE. Comparison with calculations performed using several validated codes (MCNPX2.5.0/CINDER'90, FLUKA/ORIHET and SNT) yields the ratio between simulated in-target isotope production rates and experimental amount released at any given time. This work underlines the weak points of spallation models for some released isotopes. Also, results provide relevant information for safety and radioprotection in an Accelerator Driven System (ADS) and more particularly for the gas management in a spallation target dedicated to neutron production facilities. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

First results from the HMPID detector in the ALICE experiment at LHC

The ALICE experiment is dedicated to the study of heavy-ion collisions at LHC energies. ALICE has a high-quality hadron identification system in the central region e.g. a Inner Tracking System, a large Time-Projection-Chamber, a Time-Of-Flight and the High Momentum Particle Identification Detector (HMPID). The ALICE HMPID detector has been designed to identify charged hadrons ({rho}, K, p) in the momentum range 1<p<5 GeV/c. Despite its limited geometrical acceptance, less than 10% of the central ALICE barrel, the HMPID detector has successfully accumulated enough statistics during the first proton-proton runs at LHC, to allow the detector alignment and to evaluate the calibration parameters needed to estimate its performance. Preliminary HMPID results from p-p collisions at {radical}(s) = 7 TeV and its future contribution to the ALICE physics programme, will be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

T2K: ND280 Status, Progress, and Plans

T2K(Tokai to Kamioka) is an off-axis long baseline (295 km) neutrino oscillation experiment designed to search for v{sub {mu}} {yields} v{sub e} appearance. The neutrino beam is generated using 30 GeV protons from the J-PARC facility at Tokai, Japan. The Near Detector(ND280) is located in J-PARC and the Far Detector, Super-Kamiokande, in Kamioka, Japan. Presented is a summary of the status and plans of the Near Detector suite.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Achievements and Lessons from Tevatron

For almost a quarter of a century, the Tevatron proton-antiproton collider was the centerpiece of the world's high energy physics program - beginning operation in December of 1985 until it was overtaken by LHC in 2011. The aim of the this unique scientific instrument was to explore the elementary particle physics reactions with center of mass collision energies of up to 1.96 TeV. The initial design luminosity of the Tevatron was 10{sup 30} cm{sup -2}s{sup -1}, however as a result of two decades of upgrades, the accelerator has been able to deliver 430 times higher luminosities to each of two high luminosity experiments, CDF and D0. Tevatron will be shut off September 30, 2011. The collider was arguably one of the most complex research instruments ever to reach the operation stage and is widely recognized for many technological breakthroughs and numerous physics discoveries. Below we briefly present the history of the Tevatron, major advances in accelerator physics, and technology implemented during the long quest for better and better performance. We also discuss some lessons learned from our experience.

43 PARTICLE ACCELERATORS↗

Modular Polymer Biosensors by Solvent Immersion Imprint Lithography

We recently demonstrated Solvent Immersion Imprint Lithography (SIIL), a rapid benchtop microsystem prototyping technique, including polymer functionalization, imprinting and bonding. Here, we focus on the realization of planar polymer sensors using SIIL through simple solvent immersion without imprinting. We describe SIIL’s impregnation characteristics, including an inherent mechanism that not only achieves practical doping concentrations, but their unexpected 4-fold enhancement compared to the immersion solution. Subsequently, we developed and characterized optical sensors for detecting molecular O2. To this end, a high dynamic range is reported, including its control through the immersion duration, a manifestation of SIIL’s modularity. Overall, SIIL exhibits the potential of improving the operating characteristics of polymer sensors, while significantly accelerating their prototyping, as it requires a few seconds of processing and no need for substrates or dedicated instrumentation. These are critical for O2 sensing as probed by way of example here, as well as any polymer permeable reactant.

Environmental Molecular Sciences Laboratory↗

Ka-band linearizer for the Ultra-Compact X-ray free-electron laser at UCLA

There is a strong demand for accelerating structures able to achieve higher gradients and more compact dimensions for the next generation of linear accelerators for research, industrial and medical applications. Notably innovative technologies will permit compact and affordable advanced accelerators as the linear collider and X-ray free-electron lasers (XFELs) with accelerating gradients over twice the value achieved with current technologies. In particular XFELs are able to produce coherent X-ray pulses with peak brightness 10 orders of magnitude greater than preceding approaches, which has revolutionized numerous research fields through imaging of the nanoscopic world at the time and length scale of atom-based systems, that is of femtosecond and Angstrom. There is a strong interest for combining these two fields, to form a proper tool with the goal of producing a very compact XFEL in order to investigate multi-disciplinary topics in chemistry, biology, materials science, medicine and physics. In the framework of the Ultra-Compact XFEL project under study at the University of California, Los Angeles, a high gradient radio-frequency accelerating structure for the longitudinal phase-space linearization with an integrated voltage of at least 15 MV working on 6th harmonic of the main Linac frequency is required. We here present the electromagnetic design of a cryogenic normal-conducting 8 cm long Ka-band standing-wave linearizer working on π mode with a target accelerating gradient beyond 100 MV/m. The studies have been performed analytically and numerically to investigate the beam dynamics and electromagnetic issues.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-fidelity photoneutron detection via neutron activation analysis

To interdict illicit radioactive sources and prevent nuclear terror, governments have deployed portal monitor systems at ports of entry. Such portal monitors rely upon the detection of spontaneously-emitted radiation signatures, however, detection scenarios become more challenging for highly enriched uranium, which emits relatively few spontaneous radiation signatures. Photon active interrogation techniques can augment current cargo inspection scenarios and improve detection capabilities for illicit nuclear material. A high-energy photon interrogation source can induce photofission in nuclear material, producing strong radiation signatures for detection. Prompt fission signals are of specific interest because prompt neutrons are greater than 99% of the fission signal. When using detectors capable of spectroscopy, e.g., pulse shape discrimination-capable organic scintillators, the intense interrogating source often will cause pulse pile-up, degrading particle classification. In this work, we demonstrate photoneutron detection via neutron activation of aluminum and iron. The experiments rely upon nuclear reactions that can only be induced by neutrons, and are robust against pile-up, thereby providing high-confidence neutron rates. In this work, we apply neutron activation analysis for the detection of high-energy neutrons produced by high-energy photon irradiation; the depleted uranium sample was irradiated with a 9-MeV bremsstrahlung beam. We find that the irradiated depleted uranium produced an aluminum activation flux of 1.77 × 10 5 n cm –2 s –1 and an iron-56 activation flux of 1.05 × 10 5 n cm –2 s –1 . Furthermore, the ability to detect radioactivity induced by neutrons created in (, n) and photofission reactions demonstrates a new approach for photon active interrogation to identify nuclear materials.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Finite element modeling of electropolishing of radio frequency dipole Nb crab cavity in hydrofluoric-sulfuric acid electrolyte

The superior performance of niobium superconducting radio frequency (SRF) cavities is achieved through meticulous surface treatment, notably via chemical electropolishing, ensuring exceptionally smooth surfaces. While this technique has been extensively employed for cylindrically symmetric structures, addressing more intricate geometries poses significant challenges in achieving uniform polishing and controlled material removal, especially when moving away from retractable cathodes. This presents a multifaceted electrochemical, thermal, and fluid dynamics conundrum. A prime example is the 197 MHz radio frequency dipole (RFD) crabbing cavity proposed for the Electron Ion Collider (EIC) project, exemplifying such complex structures. Our groundbreaking work integrates the localized oxide thickness variation, considering its impact on current distribution and Joule heating, within the framework of multi-physics modeling using the COMSOL® simulation suite. This approach was applied to a comprehensive model of the RFD cavity, allowing us to investigate optimal external cooling water flow conditions necessary for achieving desirable outcomes. In conclusion, this illustrates the increasing utility of such multi-physics codes to greatly aid in designing solutions to challenging processing requirements for increasingly complex accelerator cavities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Polarized Positrons at Jefferson Lab

A novel concept for producing polarized positrons at Jefferson Lab using the CEBAF polarized electron photo-injector is presented. This approach relies on the polarization transfer from low energy highly polarized electrons to positrons via bremsstrahlung followed by pair production in a conversion target. An experiment to test this concept is discussed on the basis of GEANT4 simulations. It is shown that this low energy approach, which benefits from recent advances in high current high polarization electron sources, can yield positron longitudinal polarization up to 40%.

43 PARTICLE ACCELERATORS↗

Neutrons and their Detection with Silicon Diodes

In this lecture we review the basic principles and properties of neutrons as probes for fundamental and applied research studies. We outline the nuclear reactions used for neutron sources and neutron detectors and techniques of filtered neutron beams and time-of-flight. We summarize the interaction, transport and shielding of neutrons in matter. We concentrate on the reactions employed for detection of neutrons as well as on their interaction in silicon. We indicate the features of materials used as neutron converters and highlight areas with broad applications of neutrons.

43 PARTICLE ACCELERATORS↗

3D Hydro + Cascade model at RHIC and LHC

Using the 3D Hydro + UrQMD model which can explain hot and bulk QCD matter created at RHIC successfully, we show a prediction of one particle distributions and flow at LHC. Besides, we discuss the QCD critical point search in heavy ion collisions from point of view of quantitative analyses.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The Search for a π 1 (1400) Exotic Meson in the gammap-->Δ ++ ηπ - System with CLAS

Several experiments have reported evidence for the π 1 (1400) using pion production but the results have been controversial and its existence has yet to be seen in photoproduction. Theoretical works have implied that the production amplitude will be greatly increased in photoproduction in comparison to the pion production. The reaction gammap-->Λ ++ X-->pπ + π - (η) is being studied in the photon energy range 4.4 to 5.4 GeV as a possible method of producing the π1(1400) resonance. Data were collected at Jefferson Lab in Hall B. This reaction is being investigated by detecting the pπ + π - 2gamma and reconstructing the eta through the missing-mass of the p π + π - , and comparing the results to the 2γ composite. These data have yielded a 0 (980) and a 2 (1320) in the π - eta invariant mass spectrum. Further analysis is needed to untangle the possible π1(1400) resonance from the a2(1320).

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The Spectroscopic study of {sup 33}Ar

The proton-rich nucleus {sup 33}Ar has been produced at the low-energy facility SPIRAL at GANIL. Spectroscopic studies of gamma and p emission of this nucleus were performed with the 'Silicon Cube' detection system. The analysis of proton and gamma singles and coincidence spectra allowed us to establish a complete decay scheme of this nucleus. The comparison of the Gamow-Teller strength distribution deduced from our experiment and the theoretical one obtained with the Shell Model permitted the determination of a quenching factor for the Gamow-Teller strength.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Highlights from RHIC Spin Physics Program

The Relativistic Heavy Ion Collider (RHIC) at Brookhaven National Laboratory delivers the world's highest energy polarized proton-proton collisions at a center of mass energy up to 500 GeV and provides a unique opportunity to study the quark and gluon spin structure of the proton and QCD dynamics at high energy scale. RHIC has produced many exiting physics results in recent years. The latest data from RHIC significantly constrain the gluon spin contribution to the proton spin, and the parity violating single spin asymmetry are observed for the first time in W production by both the PHENIX and STAR collaborations. In this report, I present the latest results from the PHENIX and STAR experiments, followed by a brief discussion of the future prospects of transverse physics, particularly on the importance of the unique measurements of Drell-Yan single spin asymmetry.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Characterization and limits of a cold-atom Sagnac interferometer

We present the full evaluation of a cold-atom gyroscope based on atom interferometry. We have performed extensive studies to determine the systematic errors, scale factor and sensitivity. We demonstrate that the acceleration noise can be efficiently removed from the rotation signal, allowing us to reach the fundamental limit of the quantum projection noise for short term measurements. The technical limits to the long term sensitivity and accuracy have been identified, clearing the way for the next generation of ultrasensitive atom gyroscopes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Inclusive pi0, eta, and direct photon production at high transverse momentum in p+p and d+Au collisions at sqrt(s_NN) = 200 GeV

We report a measurement of high-p{sub T} inclusive {pi}{sup 0}, {eta}, and direct photon production in p+p and d+Au collisions at {radical}s{sub NN} = 200 GeV at midrapidity (0 < {eta} < 1). Photons from the decay {pi}{sup 0} {yields} {gamma}{gamma} were detected in the barrel electromagnetic calorimeter of the STAR experiment at the Relativistic Heavy Ion Collider. The {eta} {yields} {gamma}{gamma} decay was also observed and constituted the first {eta} measurement by STAR. The first direct photon cross-section measurement by STAR is also presented; the signal was extracted statistically by subtracting the {pi}{sup 0}, {eta}, and {omega}(782) decay background from the inclusive photon distribution observed in the calorimeter. The analysis is described in detail, and the results are found to be in good agreement with earlier measurements and with next-to-leading-order perturbative QCD calculations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Indirect Observation of an In-Medium {eta}{sup '} Mass Reduction in {radical}(s{sub NN})=200 GeV Au+Au Collisions

PHENIX Collaboration and STAR Collaboration data on the intercept parameter of the two-pion Bose-Einstein correlation functions in {radical}(s{sub NN})=200 GeV Au+Au collisions are analyzed in terms of different models of hadronic multiplicities. To describe this combined PHENIX and STAR data set, an in-medium {eta}{sup '} mass reduction of at least 200 MeV is needed, at the 99.9% confidence level in the considered model class. Such a significant {eta}{sup '} mass modification may indicate the restoration of the U{sub A}(1) symmetry in a hot and dense hadronic matter and the return of the 9th ''prodigal'' Goldstone boson.