Search NASA⌕ Search

SEARCH · Search NASA

Results for “Biomedical Applications”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,783 records · Page 99

Supporting Information for manuscript: “A latitudinal gradient in S/G lignin monomer ratio driven by laccase in natural poplar variants”

Lignin composition plays a crucial role in plant structural integrity and environmental adaptation. However, the genetic and molecular mechanisms underlying natural variation in lignin composition remain poorly understood. This study investigates the syringyl-to-guaiacyl (S/G) lignin monomer ratio across a natural population of Populus trichocarpa spanning a latitudinal gradient along the Northwest coast of North America. By integrating biochemical, genomic, and geographic analysis, we identify key gene variants associated with S/G ratio differences. These datasets provide valuable insights into the evolutionary and functional genomics of lignin composition and serve as a resource for developing poplar variants optimized for forestry and bioenergy applications.

Poplar, lignin composition, laccases, latitude, ad↗

Coronary centerline extraction from CT coronary angiography images using a minimum cost path approach

Purpose: The application and large-scale evaluation of minimum cost path approaches for coronary centerline extraction from computed tomography coronary angiography (CTCA) data and the development and evaluation of a novel method to reduce the user-interaction time. Methods: A semiautomatic method based on a minimum cost path approach is evaluated for two different cost functions. The first cost function is based on a frequently used vesselness measure and intensity information, and the second is a recently proposed cost function based on region statistics. User interaction is minimized to one or two mouse clicks distally in the coronary artery. The starting point for the minimum cost path search is automatically determined using a newly developed method that finds a point in the center of the aorta in one of the axial slices. This step ensures that all computationally expensive parts of the algorithm can be precomputed. Results: The performance of the aorta localization procedure was demonstrated by a success rate of 100% in 75 images. The success rate and accuracy of centerline extraction was quantitatively evaluated on 48 coronary arteries in 12 images by comparing extracted centerlines with a manually annotated reference standard. The method was able to extract 88% and 47% of the vessel centerlines correctly using the vesselness/intensity and region statistics cost function, respectively. For only the proximal part of the vessels these values were 97% and 86%, respectively. Accuracy of centerline extraction, defined as the average distance from correctly automatically extracted parts of the centerline to the reference standard, was 0.64 mm for the vesselness/intensity and 0.51 mm for the region statistics cost function. The interobserver variability was 99% for the success rate measure and 0.42 mm for the accuracy measure. Qualitative evaluation using the best performing cost function resulted in successful centerline extraction for 233 out of the 252 coronaries (92%) in 63 additional CTCA images. Conclusions: The presented results, in combination with minimal user interaction and low computation time, show that minimum cost path approaches can effectively be applied as a preprocessing step for subsequent analysis in clinical practice and biomedical research.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-F-I-43: A Software-Based Statistical Method to Compute Low Contrast Detectability in Computed Tomography Images

Purpose: The low contrast detectability (LCD) of a CT scanner is its ability to detect and display faint lesions. The current approach to quantify LCD is achieved using vendor-specific methods and phantoms, typically by subjectively observing the smallest size object at a contrast level above phantom background. However, this approach does not yield clinically applicable values for LCD. The current study proposes a statistical LCD metric using software tools to not only to assess scanner performance, but also to quantify the key factors affecting LCD. This approach was developed using uniform QC phantoms, and its applicability was then extended under simulated clinical conditions. Methods: MATLAB software was developed to compute LCD using a uniform image of a QC phantom. For a given virtual object size, the software randomly samples the image within a selected area, and uses statistical analysis based on Student’s t-distribution to compute the LCD as the minimal Hounsfield Unit’s that can be distinguished from the background at the 95% confidence level. Its validity was assessed by comparison with the behavior of a known QC phantom under various scan protocols and a tissue-mimicking phantom. The contributions of beam quality and scattered radiation upon the computed LCD were quantified by using various external beam-hardening filters and phantom lengths. Results: As expected, the LCD was inversely related to object size under all scan conditions. The type of image reconstruction kernel filter and tissue/organ type strongly influenced the background noise characteristics and therefore, the computed LCD for the associated image. Conclusion: The proposed metric and its associated software tools are vendor-independent and can be used to analyze any LCD scanner performance. Furthermore, the method employed can be used in conjunction with the relationships established in this study between LCD and tissue type to extend these concepts to patients’ clinical CT images.

60 APPLIED LIFE SCIENCES↗

A scaling transformation for classifier output based on likelihood ratio: Applications to a CAD workstation for diagnosis of breast cancer

Purpose: The authors developed scaling methods that monotonically transform the output of one classifier to the ''scale'' of another. Such transformations affect the distribution of classifier output while leaving the ROC curve unchanged. In particular, they investigated transformations between radiologists and computer classifiers, with the goal of addressing the problem of comparing and interpreting case-specific values of output from two classifiers. Methods: Using both simulated and radiologists' rating data of breast imaging cases, the authors investigated a likelihood-ratio-scaling transformation, based on ''matching'' classifier likelihood ratios. For comparison, three other scaling transformations were investigated that were based on matching classifier true positive fraction, false positive fraction, or cumulative distribution function, respectively. The authors explored modifying the computer output to reflect the scale of the radiologist, as well as modifying the radiologist's ratings to reflect the scale of the computer. They also evaluated how dataset size affects the transformations. Results: When ROC curves of two classifiers differed substantially, the four transformations were found to be quite different. The likelihood-ratio scaling transformation was found to vary widely from radiologist to radiologist. Similar results were found for the other transformations. Our simulations explored the effect of database sizes on the accuracy of the estimation of our scaling transformations. Conclusions: The likelihood-ratio-scaling transformation that the authors have developed and evaluated was shown to be capable of transforming computer and radiologist outputs to a common scale reliably, thereby allowing the comparison of the computer and radiologist outputs on the basis of a clinically relevant statistic.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Spatiotemporal Monte Carlo transport methods in x-ray semiconductor detectors: Application to pulse-height spectroscopy in a-Se

Purpose: The authors describe a detailed Monte Carlo (MC) method for the coupled transport of ionizing particles and charge carriers in amorphous selenium (a-Se) semiconductor x-ray detectors, and model the effect of statistical variations on the detected signal. Methods: A detailed transport code was developed for modeling the signal formation process in semiconductor x-ray detectors. The charge transport routines include three-dimensional spatial and temporal models of electron-hole pair transport taking into account recombination and trapping. Many electron-hole pairs are created simultaneously in bursts from energy deposition events. Carrier transport processes include drift due to external field and Coulombic interactions, and diffusion due to Brownian motion. Results: Pulse-height spectra (PHS) have been simulated with different transport conditions for a range of monoenergetic incident x-ray energies and mammography radiation beam qualities. Two methods for calculating Swank factors from simulated PHS are shown, one using the entire PHS distribution, and the other using the photopeak. The latter ignores contributions from Compton scattering and K-fluorescence. Comparisons differ by approximately 2% between experimental measurements and simulations. Conclusions: The a-Se x-ray detector PHS responses simulated in this work include three-dimensional spatial and temporal transport of electron-hole pairs. These PHS were used to calculate the Swank factor and compare it with experimental measurements. The Swank factor was shown to be a function of x-ray energy and applied electric field. Trapping and recombination models are all shown to affect the Swank factor.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-F-T-631: Linear Accelerator-Based Frameless Extracranial Radiosurgery for Treatment of Occipital Neuralgia for Non-Surgical Candidates

Purpose: Occipital neuralgia is a condition wherein pain is transmitted by the occipital nerves. Non-invasive therapies generally alleviate symptoms; however, persistent or recurring pain may require invasive procedures. Repeated invasive procedures upon failure are considered higher risk and are often contraindicated due to compounding inherent risk. SRS has not been explored as a treatment option largely due to the extracranial nature of the target (as opposed to the similar, more established trigeminal neuralgia), but advances in linear-accelerator frameless-based SRS now present an opportunity to evaluate the novel potential of this modality for this application. Methods: Patient presented with severe occipital pain following decompression and fusion of the cervical vertebrae with prior intervention attempted via radiofrequency ablation yielding temporary pain cessation. A 0.6 mm slice spacing CT was obtained for treatment planning, and a cervical spine oriented 1.0 mm slice spacing CT myelogram was obtained for the purpose of defining the targeted C2 occipital dorsal root ganglion (to receive 80 Gy to the isocenter) and spinal cord. Results: The spinal cord was most proximally 12.0 mm from the isocenter receiving a maximum dose of 3.36 Gy, and doses to 0.35 and 1.2 cc of 1.84 Gy and 0.79 Gy, respectively. The brain maximum dose was 2.29 Gy. The treatment was successfully performed with a NovalisTX (Varian) equipped with ExacTrac stereoscopic x-ray image guidance (BrainLAB). Treatment time was 59 minutes for 18,323 MUs. Imaging was performed prior to each arc delivery resulting in twenty-one imaging sessions (twelve requiring positional corrections with the remaining verified within tolerance). The average deviation magnitude requiring a positional or rotational correction was 0.96±0.25 mm, 0.8±0.41° while the average deviation magnitude deemed within tolerance was 0.41±0.12 mm, 0.57±0.28°. Conclusion: Linear accelerator-based frameless radiosurgery provides an accurate, non-invasive alternative for treating occipital neuralgia where an invasive procedure is contraindicated.

60 APPLIED LIFE SCIENCES↗

TH-AB-209-11: Breast Microcalcification Classification Using Spectral X-Ray Coherent Scatter Computed Tomography

Purpose: To investigate the ability of Coherent Scatter Computed Tomography (CSCT) to distinguish non-invasively between type I calcifications, consisting of calcium oxalate dihydrate (CO) compounds which are more often associated with benign lesions, and type II calcifications containing hydroxyapatite (HA) which are predominantly associated with malignant tumors. Methods: The coherent scatter cross sections of HA and CO were measured using an energy dispersive x-ray diffractometer. The measured cross sections were introduced into MC-GPU Monte Carlo simulation code for studying the applicability of CSCT to discriminate between the two types of microcalcifications within the whole breast. Simulations were performed on a virtual phantom with inserted HA and CO spots of different sizes and placed in regions of interest having different background compositions. We considered a polychromatic x-ray source and an energy resolving photon counting detector. We applied an algorithm that estimates scatter components in projection space in order to obtain material-specific images of the breast. As material components adipose, glandular, HA and CO were used. The relative contrast of HA and CO components were used for type I and type II microcalcification discrimination. Results: The reconstructed CSCT images showed material-specific component-contrast values, with the highest CO or HA component contrast corresponding generally to the actual CO or HA feature, respectively. The discrimination performance varies with the x-ray intensity, calcification size, and background composition. The results were summarized using receiver operating characteristic (ROC) analysis with the area under the curve (AUC) taken as an overall indicator of discrimination performance and showing high AUC values up to unity. Conclusion: The simulation results obtained for a uniform breast imaging phantom indicate that CSCT has potential to be used as a non-invasive method for discrimination between type I and type II microcalcifications.

60 APPLIED LIFE SCIENCES↗

Distribution Atlas of Proliferating Bone Marrow in Non-Small Cell Lung Cancer Patients Measured by FLT-PET/CT Imaging, With Potential Applicability in Radiation Therapy Planning

Purpose: Proliferating bone marrow is exquisitely sensitive to ionizing radiation. Knowledge of its distribution could improve radiation therapy planning to minimize unnecessary marrow exposure and avoid consequential prolonged myelosuppression. [18F]-Fluoro-3-deoxy-3-L-fluorothymidine (FLT)–positron emission tomography (PET) is a novel imaging modality that provides detailed quantitative images of proliferating tissues, including bone marrow. We used FLT-PET imaging in cancer patients to produce an atlas of marrow distribution with potential clinical utility. Methods and Materials: The FLT-PET and fused CT scans of eligible patients with non-small cell lung cancer (no distant metastases, no prior cytotoxic exposure, no hematologic disorders) were reviewed. The proportions of skeletal FLT activity in 10 predefined bony regions were determined and compared according to age, sex, and recent smoking status. Results: Fifty-one patients were studied: 67% male; median age 68 (range, 31-87) years; 8% never smokers; 70% no smoking in the preceding 3 months. Significant differences in marrow distribution occurred between sex and age groups. No effect was detected from smoking in the preceding 3 months. Using the mean percentages of FLT uptake per body region, we created an atlas of the distribution of functional bone marrow in 4 subgroups defined by sex and age. Conclusions: This atlas has potential utility for estimating the distribution of active marrow in adult cancer patients to guide radiation therapy planning. However, because of interindividual variation it should be used with caution when radiation therapy risks ablating large proportions of active marrow; in such cases, individual FLT-PET scans may be required.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

First Experience With Real-Time EPID-Based Delivery Verification During IMRT and VMAT Sessions

Purpose: Gantry-mounted megavoltage electronic portal imaging devices (EPIDs) have become ubiquitous on linear accelerators. WatchDog is a novel application of EPIDs, in which the image frames acquired during treatment are used to monitor treatment delivery in real time. We report on the preliminary use of WatchDog in a prospective study of cancer patients undergoing intensity modulated radiation therapy (IMRT) and volumetric modulated arc therapy (VMAT) and identify the challenges of clinical adoption. Methods and Materials: At the time of submission, 28 cancer patients (head and neck, pelvis, and prostate) undergoing fractionated external beam radiation therapy (24 IMRT, 4 VMAT) had ≥1 treatment fraction verified in real time (131 fractions or 881 fields). EPID images acquired continuously during treatment were synchronized and compared with model-generated transit EPID images within a frame time (∼0.1 s). A χ comparison was performed to cumulative frames to gauge the overall delivery quality, and the resulting pass rates were reported graphically during treatment delivery. Every frame acquired (500-1500 per fraction) was saved for postprocessing and analysis. Results: The system reported the mean ± standard deviation in real time χ 91.1% ± 11.5% (83.6% ± 13.2%) for cumulative frame χ analysis with 4%, 4 mm (3%, 3 mm) criteria, global over the integrated image. Conclusions: A real-time EPID-based radiation delivery verification system for IMRT and VMAT has been demonstrated that aims to prevent major mistreatments in radiation therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Phantom-based experimental validation of computational fluid dynamics simulations on cerebral aneurysms

Purpose: Recently, image-based computational fluid dynamics (CFD) simulation has been applied to investigate the hemodynamics inside human cerebral aneurysms. The knowledge of the computed three-dimensional flow fields is used for clinical risk assessment and treatment decision making. However, the reliability of the application specific CFD results has not been thoroughly validated yet. Methods: In this work, by exploiting a phantom aneurysm model, the authors therefore aim to prove the reliability of the CFD results obtained from simulations with sufficiently accurate input boundary conditions. To confirm the correlation between the CFD results and the reality, virtual angiograms are generated by the simulation pipeline and are quantitatively compared to the experimentally acquired angiograms. In addition, a parametric study has been carried out to systematically investigate the influence of the input parameters associated with the current measuring techniques on the flow patterns. Results: Qualitative and quantitative evaluations demonstrate good agreement between the simulated and the real flow dynamics. Discrepancies of less than 15% are found for the relative root mean square errors of time intensity curve comparisons from each selected characteristic position. The investigated input parameters show different influences on the simulation results, indicating the desired accuracy in the measurements. Conclusions: This study provides a comprehensive validation method of CFD simulation for reproducing the real flow field in the cerebral aneurysm phantom under well controlled conditions. The reliability of the CFD is well confirmed. Through the parametric study, it is possible to assess the degree of validity of the associated CFD model based on the parameter values and their estimated accuracy range.

42 ENGINEERING↗

Can protein expression be ‘solved’?

Recombinant protein expression is central to biotechnology’s application in academic exploration as well as human health, climate applications and the bioeconomy in general. However, not all proteins can be expressed in all organisms, and the field lacks a predictive model of soluble protein overexpression that could replace laborious experimental trial-and-error. Here, we discuss the state of the field and identify the lack of large, high-fidelity datasets as the primary bottleneck to progress. We review possible assays that could be used for data collection to identify a path toward an extensible experimental platform for collecting soluble recombinant protein overexpression data across organisms. We suggest that the resulting dataset should be used to train increasingly generalizable predictive models of protein expression to answer the question: “How can predictive protein expression be solved?”.

59 BASIC BIOLOGICAL SCIENCES↗

In Situ Investigation of Upper Airway Occlusion in Sleep Disordered Breathing Using Ultrasonic Transducer Arrays

This work presents a novel application of ultrasound for the real-time, non-invasive investigation of occlusion of the upper airway during events of obstructive sleep apnea/hypopnea syndrome. It is hypothesized that ultrasonic pulses applied to the neck during apneic events produce spectral and temporal features that can detect apnea occurrence. Theoretical models of ultrasound propagation and an in vitro test were conducted to test this hypothesis in both transmission and reflection modes. Complete specifications and technical details of the system design and fabrication, which is mounted on each subject’s neck, are presented, including the methodology. Nine patients (seven male and two female, mean age of 42 years, with a range of 25 to 56 years, and body mass index 37.6 ± 6.6 kg/m2) were recruited for a full night study, which included simultaneous nocturnal polysomnography for the validation of the results. Nine temporal features and four spectral features were extracted from the envelope of the received pulse waveform. These were used to compute 26 metrics to quantify the changes in the ultrasonic waveforms between normal breathing and apneic events. The statistical analysis of the collected ultrasonic data showed that at least two or more of the proposed features could detect apneic events in all subjects. The findings establish the feasibility of the proposed method as a cost-effective and non-invasive OSAHS screening tool.

60 APPLIED LIFE SCIENCES↗

Tumor Response After Stereotactic Body Radiation Therapy to Nonspine Bone Metastases: An Evaluation of Response Criteria

Purpose: To evaluate the applicability of the Response Evaluation Criteria in Solid Tumors (RECIST 1.1) and University of Texas MD Anderson (MDA) Cancer Center criteria in the setting of stereotactic body radiation therapy (SBRT) to nonspine bone metastases. Methods: Patients who were treated with SBRT to nonspine bone metastases were identified by retrospective chart review. An independent musculoskeletal radiologist evaluated response to treatment using computed tomography (CT) scans. Results: Thirty-three patients were treated to 42 nonspine bone metastases. The most common primary cancer cites were renal cell carcinoma (RCC) (33.3%), lung (24.2%), and prostate (18.2%). Bone metastases were either mainly lytic (57.1%), mainly sclerotic (28.6%), or mixed (14.3%). When lytic and sclerotic lesions were evaluated according to RECIST 1.1, local control (LC) was 83%, 85%, 88%, and 80% for those with CT imaging between months 1 to 3, 4 to 6, 7 to 9, and 10 to 12, respectively. When evaluated by the MDA criteria by density, LC within each time period was slightly greater. Overall LC decreased considerably when evaluated by MDA in terms of size. Conclusions: Consensus definitions of response are required as they have implications on clinical trials and disease management. Without consistent response criteria, outcomes from clinical trials cannot be compared and treatment efficacy remains undetermined.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

TU-AB-204-00: CDRH/FDA Regulatory Processes and Device Science Activities

The responsibilities of the Food and Drug Administration (FDA) have increased since the inception of the Food and Drugs Act in 1906. Medical devices first came under comprehensive regulation with the passage of the 1938 Food, Drug, and Cosmetic Act. In 1971 FDA also took on the responsibility for consumer protection against unnecessary exposure to radiation-emitting devices for home and occupational use. However it was not until 1976, under the Medical Device Regulation Act, that the FDA was responsible for the safety and effectiveness of medical devices. This session will be presented by the Division of Radiological Health (DRH) and the Division of Imaging, Diagnostics, and Software Reliability (DIDSR) from the Center for Devices and Radiological Health (CDRH) at the FDA. The symposium will discuss on how we protect and promote public health with a focus on medical physics applications organized into four areas: pre-market device review, post-market surveillance, device compliance, current regulatory research efforts and partnerships with other organizations. The pre-market session will summarize the pathways FDA uses to regulate the investigational use and commercialization of diagnostic imaging and radiation therapy medical devices in the US, highlighting resources available to assist investigators and manufacturers. The post-market session will explain the post-market surveillance and compliance activities FDA performs to monitor the safety and effectiveness of devices on the market. The third session will describe research efforts that support the regulatory mission of the Agency. An overview of our regulatory research portfolio to advance our understanding of medical physics and imaging technologies and approaches to their evaluation will be discussed. Lastly, mechanisms that FDA uses to seek public input and promote collaborations with professional, government, and international organizations, such as AAPM, International Electrotechnical Commission (IEC), Image Gently, and the Quantitative Imaging Biomarkers Alliance (QIBA) among others, to fulfill FDA’s mission will be discussed. Learning Objectives: Understand FDA’s pre-market and post-market review processes for medical devices Understand FDA’s current regulatory research activities in the areas of medical physics and imaging products Understand how being involved with AAPM and other organizations can also help to promote innovative, safe and effective medical devices J. Delfino, nothing to disclose.

60 APPLIED LIFE SCIENCES↗

SU-E-I-04: Improving CT Quality for Radiation Therapy of Patients with High Body Mass Index Using Iterative Reconstruction Algorithms

Purpose: Iterative reconstruction (IR) algorithms are developed to improve CT image quality (IQ) by reducing noise without diminishing spatial resolution or contrast. The CT IQ for patients with a high Body Mass Index (BMI) can suffer from increased noise due to photon starvation. The purpose of this study is to investigate and to quantify the IQ enhancement for high BMI patients through the application of IR algorithms. Methods: CT raw data collected for 6 radiotherapy (RT) patients with BMI, greater than or equal to 30 were retrospectively analyzed. All CT data were acquired using a CT scanner (Somaton Definition AS Open, Siemens) installed in a linac room (CT-on-rails) using standard imaging protocols. The CT data were reconstructed using the Sinogram Affirmed Iterative Reconstruction (SAFIRE) and Filtered Back Projection (FBP) methods. IQ metrics of the obtained CTs were compared and correlated with patient depth and BMI. The patient depth was defined as the largest distance from anterior to posterior along the bilateral symmetry axis. Results: IR techniques are demonstrated to preserve contrast and reduce noise in comparison to traditional FBP. Driven by the reduction in noise, the contrast to noise ratio is roughly doubled by adopting the highest SAFIRE strength. A significant correlation was observed between patient depth and IR noise reduction through Pearson’s correlation test (R = 0.9429/P = 0.0167). The mean patient depth was 30.4 cm and the average relative noise reduction for the strongest iterative reconstruction was 55%. Conclusion: The IR techniques produce a measureable enhancement to CT IQ by reducing the noise. Dramatic noise reduction is evident for the high BMI patients. The improved CT IQ enables more accurate delineation of tumors and organs at risk and more accuarte dose calculations for RT planning and delivery guidance. Supported by Siemens.

60 APPLIED LIFE SCIENCES↗

TH-EF-207A-05: Feasibility of Applying SMEIR Method On Small Animal 4D Cone Beam CT Imaging

Purpose: Small animal cone beam CT imaging has been widely used in preclinical research. Due to the higher respiratory rate and heat beats of small animals, motion blurring is inevitable and needs to be corrected in the reconstruction. Simultaneous motion estimation and image reconstruction (SMEIR) method, which uses projection images of all phases, proved to be effective in motion model estimation and able to reconstruct motion-compensated images. We demonstrate the application of SMEIR for small animal 4D cone beam CT imaging by computer simulations on a digital rat model. Methods: The small animal CBCT imaging system was simulated with the source-to-detector distance of 300 mm and the source-to-object distance of 200 mm. A sequence of rat phantom were generated with 0.4 mm{sup 3} voxel size. The respiratory cycle was taken as 1.0 second and the motions were simulated with a diaphragm motion of 2.4mm and an anterior-posterior expansion of 1.6 mm. The projection images were calculated using a ray-tracing method, and 4D-CBCT were reconstructed using SMEIR and FDK methods. The SMEIR method iterates over two alternating steps: 1) motion-compensated iterative image reconstruction by using projections from all respiration phases and 2) motion model estimation from projections directly through a 2D-3D deformable registration of the image obtained in the first step to projection images of other phases. Results: The images reconstructed using SMEIR method reproduced the features in the original phantom. Projections from the same phase were also reconstructed using FDK method. Compared with the FDK results, the images from SMEIR method substantially improve the image quality with minimum artifacts. Conclusion: We demonstrate that it is viable to apply SMEIR method to reconstruct small animal 4D-CBCT images.

60 APPLIED LIFE SCIENCES↗

Comprehensive Assessments of RNA-seq by the SEQC Consortium: FDA-Led Efforts Advance Precision Medicine

Studies on gene expression in response to therapy have led to the discovery of pharmacogenomics biomarkers and advances in precision medicine. Whole transcriptome sequencing (RNA-seq) is an emerging tool for profiling gene expression and has received wide adoption in the biomedical research community. However, its value in regulatory decision making requires rigorous assessment and consensus between various stakeholders, including the research community, regulatory agencies, and industry. The FDA-led SEquencing Quality Control (SEQC) consortium has made considerable progress in this direction, and is the subject of this review. Specifically, three RNA-seq platforms (Illumina HiSeq, Life Technologies SOLiD, and Roche 454) were extensively evaluated at multiple sites to assess cross-site and cross-platform reproducibility. The results demonstrated that relative gene expression measurements were consistently comparable across labs and platforms, but not so for the measurement of absolute expression levels. As part of the quality evaluation several studies were included to evaluate the utility of RNA-seq in clinical settings and safety assessment. The neuroblastoma study profiled tumor samples from 498 pediatric neuroblastoma patients by both microarray and RNA-seq. RNA-seq offers more utilities than microarray in determining the transcriptomic characteristics of cancer. However, RNA-seq and microarray-based models were comparable in clinical endpoint prediction, even when including additional features unique to RNA-seq beyond gene expression. The toxicogenomics study compared microarray and RNA-seq profiles of the liver samples from rats exposed to 27 different chemicals representing multiple toxicity modes of action. Cross-platform concordance was dependent on chemical treatment and transcript abundance. Though both RNA-seq and microarray are suitable for developing gene expression based predictive models with comparable prediction performance, RNA-seq offers advantages over microarray in profiling genes with low expression. The rat BodyMap study provided a comprehensive rat transcriptomic body map by performing RNA-Seq on 320 samples from 11 organs in either sex of juvenile, adolescent, adult and aged Fischer 344 rats. Lastly, the transferability study demonstrated that signature genes of predictive models are reciprocally transferable between microarray and RNA-seq data for model development using a comprehensive approach with two large clinical data sets. This result suggests continued usefulness of legacy microarray data in the coming RNA-seq era. In conclusion, the SEQC project enhances our understanding of RNA-seq and provides valuable guidelines for RNA-seq based clinical application and safety evaluation to advance precision medicine.

59 BASIC BIOLOGICAL SCIENCES↗

Characterization of scintillator-based detectors for few-ten-keV high-spatial-resolution x-ray imaging

Purpose: High-spatial-resolution x-ray imaging in the few-ten-keV range is becoming increasingly important in several applications, such as small-animal imaging and phase-contrast imaging. The detector properties critically influence the quality of such imaging. Here the authors present a quantitative comparison of scintillator-based detectors for this energy range and at high spatial frequencies. Methods: The authors determine the modulation transfer function, noise power spectrum (NPS), and detective quantum efficiency for Gadox, needle CsI, and structured CsI scintillators of different thicknesses and at different photon energies. An extended analysis of the NPS allows for direct measurements of the scintillator effective absorption efficiency and effective light yield as well as providing an alternative method to assess the underlying factors behind the detector properties. Results: There is a substantial difference in performance between the scintillators depending on the imaging task but in general, the CsI based scintillators perform better than the Gadox scintillators. At low energies (16 keV), a thin needle CsI scintillator has the best performance at all frequencies. At higher energies (28–38 keV), the thicker needle CsI scintillators and the structured CsI scintillator all have very good performance. The needle CsI scintillators have higher absorption efficiencies but the structured CsI scintillator has higher resolution. Conclusions: The choice of scintillator is greatly dependent on the imaging task. The presented comparison and methodology will assist the imaging scientist in optimizing their high-resolution few-ten-keV imaging system for best performance.

60 APPLIED LIFE SCIENCES↗