Search NASA⌕ Search

SEARCH · Search NASA

Results for “CALIBRATION STANDARDS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,783 records · Page 99

CLARREO Pathfinder Mission Overview and its Intercalibration Capabilities

NASA's Climate Absolute Radiance and Refractivity Observatory (CLARREO) Pathfinder (CPF) mission will deploy an Earth-observing reflected solar (RS) spectrometer, designed to measure Earth-reflected solar radiation from the International Space Station with a remarkable SI-traceable radiometric uncertainty of 0.3% (k=1). This spectrometer, known as the Hyperspectral Imager for Climate Science (HySICS), will provide measurements within a spectral range of 350-2300 nm with 3-nm spectral intervals. Covering a nadir swath of 70 km, HySICS captures 480 discrete measurement pixels that provide spectrally-resolved Earth-reflected radiances. The CPF mission encompasses two principal objectives. The first objective is to demonstrate on-orbit calibration methodologies that achieve and uphold an unprecedented level of accuracy while maintaining traceability to SI standards. The second objective is to showcase an innovative on-orbit intercalibration approach, which involves the intercalibration of two other RS sensors—namely, the shortwave (SW) channel of the Clouds and the Earth’s Radiant Energy System (CERES) and the Reflective Solar (RS) bands of the Visible Infrared Imager Radiometer Suite (VIIRS)—against CPF benchmark measurements. The targeted intercalibration methodology uncertainty for these target instruments is 0.3% (k=1). Empowered by the CPF payload's two-axis pointing capability, moderate spatial sampling of 0.5 km, and wide spectral coverage, the CPF instrument will capture near-simultaneous temporal, spatial, angular, and spectrally matched observations with intercalibration targets. The CPF intercalibration science development team has devised novel methods to address spatial, spectral, polarization, and angular differences between CPF and the target instruments' intercalibration footprints to achieve the stringent 0.3% intercalibration methodology uncertainty. Comprehensive details of these methods and their validation will be elaborated upon during the conference presentation.

Hyperspectral↗

A Search for Light Weakly-Interacting Massive Particles with SuperCDMS and Applications to Neutrino Physics

Cosmological and astrophysical evidence indicates that 85% of the matter content of the universe is in the form of non-baryonic dark matter. A large number of experiments are currently undertaking searches for weakly-interacting massive particles (WIMPs), the leading class of particle candidates for dark matter. This thesis describes the results of such a search with the SuperCDMS experiment, which uses Ge detectors cooled to 50 mK to detect ionization and phonons produced by particle interactions. We perform a blind analysis of 577 kg d of exposure on 7 detectors targeting WIMPs with masses < 30GeV/$c^{2}$, where anomalous results have been reported by previous experiments. No significant excess is observed and we set an upper limit on the spin-independent WIMP-nucleon cross section of 1.2 x 10$^{-42}$ cm2 at 8 GeV/$c^{2}$ We also set constraints on dark matter interactions independent of the dark matter halo physics, as well as on annual modulation of a dark matter signal. Cryogenic detectors similar to SuperCDMS also have potential applications in neutrino physics. We study several configurations in which dark matter detectors could be used with an intense neutrino source to detect an unmeasured Standard Model process called coherent neutrino scattering. This process may be useful, for example, as a calibration for next-generation dark matter detectors, and for constraining eV-scale sterile neutrinos. In addition, small cryogenic X-ray detectors on sounding rockets with large fields-of-view have the unique ability to constrain sterile neutrino dark matter. We set limits on sterile neutrino dark matter using an observation by the XQC instrument, and discuss prospects for a future observation of the galactic center using the Micro-X instrument.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Development of a Dynamic Lidar Uncertainty Framework

As wind turbine sizes increase and wind energy expands to more complex and remote sites, remote-sensing devices such as lidars are expected to play a key role in wind resource assessment and power performance testing. The switch to remote-sensing devices represents a paradigm shift in the way the wind industry typically obtains and interprets measurement data for wind energy. For example, the measurement techniques and sources of uncertainty for a remote-sensing device are vastly different from those associated with a cup anemometer on a meteorological tower. Current IEC standards for quantifying remote sensing device uncertainty for power performance testing consider uncertainty due to mounting, calibration, and classification of the remote sensing device, among other parameters. Values of the uncertainty are typically given as a function of the mean wind speed measured by a reference device and are generally fixed, leading to climatic uncertainty values that apply to the entire measurement campaign. However, real-world experience and a consideration of the fundamentals of the measurement process have shown that lidar performance is highly dependent on atmospheric conditions, such as wind shear, turbulence, and aerosol content. At present, these conditions are not directly incorporated into the estimated uncertainty of a lidar device. In this presentation, we describe the development of a new dynamic lidar uncertainty framework that adapts to current flow conditions and more accurately represents the actual uncertainty inherent in lidar measurements under different conditions. In this new framework, sources of uncertainty are identified for estimation of the line-of-sight wind speed and reconstruction of the three-dimensional wind field. These sources are then related to physical processes caused by the atmosphere and lidar operating conditions. The framework is applied to lidar data from a field measurement site to assess the ability of the framework to predict errors in lidar-measured wind speed. The results show how uncertainty varies over time and can be used to help select data with different levels of uncertainty for different applications, for example, low uncertainty data for power performance testing versus all data for plant performance monitoring.

17 WIND ENERGY↗

Quantitative infrared spectroscopy of environmentally sensitive and rough materials

Fourier transform infrared (FTIR) spectroscopy is a widely used characterization technique for studying chemical compositions and lightmatter interactions in the infrared range. However, it remains challenging to use conventional FTIR equipment to characterize materials that are environmentally sensitive and/or have rough surfaces due to their dynamic response to external stimuli (e.g., humidity) and light scattering from the sample surface. Here, we describe an approach enabling quantitative infrared spectroscopy measurements of these challenging samples, including transmittance, reflectance, and emissivity. We designed and 3D-printed a miniaturized environmental chamber that can be directly inserted into the sample holder of a conventional integrating sphere to perform total transmission and reflection measurements in controlled environments. Moreover, a calibration method was developed to exclude light scattering from rough surfaces of the sample and the distortion created by infrared windows. To illustrate the potential application of this method, we have performed quantitative infrared measurements, both specular and diffusive, on a sapphire standard reference with a specular surface, as well as a textile sample that has a rough surface and is dynamically responsive to changes in humidity. The calibrated results measured with the equipped chamber match those measured without the IR windows, demonstrating the viability of our environmental chamber and the proposed calibration method. This quantitative infrared spectroscopy measurement technique may help advance fields such as metasurfaces and adaptive textiles, where samples are often rough, dynamically responsive, and/or environmentally sensitive.

3D printing↗

Photometric Calibration for the Beijing–Arizona Sky Survey and Mayall z -band Legacy Survey

We present the photometric calibration of the Beijing–Arizona Sky Survey and Mayall z-band Legacy Survey, which are two of the three wide-field optical legacy imaging surveys to provide the baseline targeting data for the Dark Energy Spectroscopic Instrument project. The method of our photometric calibration is subdivided into the external and internal processes. The former utilizes the point-source objects of Pan-STARRS1 survey (PS1) as the reference standards to achieve the zero points of the absolute flux for individual exposures. And then the latter revise the zero points to make them consistent across the survey based on multiple tilings and large offset overlaps. Our process achieves a homogeneous photometric calibration over most of the sky with precision better than 10 mmag for g and r bands, 15 mmag for z band. The accuracy of the calibration is better than 1% at the bright end (16–18 mag) over most of the survey area.

79 ASTRONOMY AND ASTROPHYSICS↗

Evaluation of vicarious calibration for airborne sensors using RadCalNet

Vicarious calibration approaches using in-situ measurements are key techniques applied to on-orbit remote sensors. The in-situ measurements have advantages in terms of traceability and quantifiable accuracy that make them ideal for inter-consistency studies of on-orbit sensors. The Committee on Earth Observation Satellites Working Group on Calibration and Validation Infrared Visible Optical Sensors initiated the Radiometric Calibration Network (RadCalNet) to provide automated surface and top-of-atmosphere (TOA) reflectance data from multiple participating ground sites to the worldwide user community. RadCalNet standardizes protocols for collecting data, processes TOA reflectance, and provides International System of Units traceable uncertainty budgets for the five currently operating sites. RadCalNet data from the Railroad Valley Playa, Nevada, site was used to provide an SI-traceable, absolute radiometric calibration of the Enhanced MODIS Airborne Simulator as part of an overflight of opportunity during the FIREX-AQ campaign. The results shown here demonstrate the utility of RadCalNet data for absolute radiometric calibration of airborne imagers making flights of opportunity without the need for coordination with a field validation team.

Sensors↗

Simultaneous and Constrained Calibration of Multiple Hyperspectral Images Through a New Generalized Empirical Line Model

The empirical line (EL) calibration method is commonly used for atmospheric correction of remotely sensed spectral images and recovery of surface reflectance. The current EL-based methods are applicable to calibrate only single images. Therefore, the use of the EL calibration is impractical for imaging campaigns, where many (partially overlapped) images are acquired to cover a large area. In addition, the EL results are unconstrained and an undesired reflectance with negative values or larger than 100% can be obtained. In this paper, we use the standard EL model to formulate a new generalized empirical line (GEL) model. Based on the GEL, we present a novel method for simultaneous and constrained calibration of multiple images. This new method allows for calibration through multiple image constrained empirical line (MIcEL) and three additional calibration modes. Given a set of images, we use the available ground targets and automatically extracted tie points between overlapping images to calibrate all the images in the set simultaneously. Quantitative and visual assessments of the proposed method were carried out relatively to the off-the-shelf method quick atmospheric correction (QUAC), using real hyperspectral images and field measurements. The results clearly show the superiority of MIcEL with respect to the minimization of the difference between the reflectance values of the same object in different overlapping images. An assessment of the absolute accuracy, with respect to 11 field measurement points, shows that the accuracy of MIcEL, with an average mean absolute error (MAE) of ~11%, is comparable with respect to the QUAC.

47 OTHER INSTRUMENTATION↗

Linking big models to big data: efficient ecosystem model calibration through Bayesian model emulation

Data-model integration plays a critical role in assessing and improving our capacity to predict ecosystem dynamics. Similarly, the ability to attach quantitative statements of uncertainty around model forecasts is crucial for model assessment and interpretation and for setting field research priorities. Bayesian methods provide a rigorous data assimilation framework for these applications, especially for problems with multiple data constraints. However, the Markov chain Monte Carlo (MCMC) techniques underlying most Bayesian calibration can be prohibitive for computationally demanding models and large datasets. We employ an alternative method, Bayesian model emulation of sufficient statistics, that can approximate the full joint posterior density, is more amenable to parallelization, and provides an estimate of parameter sensitivity. Analysis involved informative priors constructed from a meta-analysis of the primary literature and specification of both model and data uncertainties, and it introduced novel approaches to autocorrelation corrections on multiple data streams and emulating the sufficient statistics surface. We report the integration of this method within an ecological workflow management software, Predictive Ecosystem Analyzer (PEcAn), and its application and validation with two process-based terrestrial ecosystem models: SIPNET and ED2. In a test against a synthetic dataset, the emulator was able to retrieve the true parameter values. A comparison of the emulator approach to standard brute-force MCMC involving multiple data constraints showed that the emulator method was able to constrain the faster and simpler SIPNET model's parameters with comparable performance to the brute-force approach but reduced computation time by more than 2 orders of magnitude. The emulator was then applied to calibration of the ED2 model, whose complexity precludes standard (brute-force) Bayesian data assimilation techniques. Both models are constrained after assimilation of the observational data with the emulator method, reducing the uncertainty around their predictions. Performance metrics showed increased agreement between model predictions and data. Our study furthers efforts toward reducing model uncertainties, showing that the emulator method makes it possible to efficiently calibrate complex models.

58 GEOSCIENCES↗

Calibration of the DUNE Far Detector Using Cosmic-ray Muon Events

The Deep Underground Neutrino Experiment (DUNE) aims to set new limits on parameters associated with neutrino oscillations, neutrino astrophysics, and beyond the Standard Model (SM) searches such as nucleon decay. DUNE will quantify the magnitude of CP violation in the lepton sector, and determine the neutrino mass ordering. These benefit highly from the large target mass and excellent imaging, tracking, and particle identification capabilities of Liquid Argon Time Projection Chambers (LArTPCs). Detector calibration is essential to make precise physics measurements. For instance, accurate energy reconstruction is necessary for measuring many of the aforementioned quantities with the precision required for discovering new physics and fully exploiting the capabilities of the detector. Cosmic muons are a freely available natural source of calorimetric data and can be used for calibrating various detector parameters. This thesis provides an analysis of simulated cosmic-ray muon events generated with the Muon Simulation Underground (MUSUN) generator in the DUNE horizontal drift (HD) far detector (FD). The study focuses on analysing the energy and angular distribution of various classes of muon events, as well as characterising the different particles produced by cosmic muon interactions. The analysis of π0 → 2γ events within the cosmic-ray muon sample is presented in this thesis with a detailed study of reconstructing electromagnetic showers. The π0 mass is reconstructed within the DUNE FD, yielding a value of (136 ± 7) MeV/c2. Additionally, the thesis introduces methods for dE/dx calibration using simulated and reconstructed muon tracks. A calibration constant Ccal = (5.469 ± 0.003) × 10−3 ADC × tick/e is obtained through a model-dependent calibration process, where 1 tick corresponds to 500 ns of sampling time of an ADC. Furthermore, a calibration technique is presented, demonstrating precise translation from dQ/dx to dE/dx. This calibration method is applied to stopping muons, charged pions, and protons in the DUNE FD, addressing the measurement of energy loss in the detector volume. These are important calibrations of the DUNE FD and will contribute to achieving the exciting physics goals of the experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation of two gas-dilution methods for instrument calibration

Two gas dilution methods were evaluated for use in the calibration of analytical instruments used in air pollution studies. A dual isotope fluorescence carbon monoxide analyzer was used as the transfer standard. The methods are not new but some modifications are described. The rotary injection gas dilution method was found to be more accurate than the closed loop method. Results by the two methods differed by 5 percent. This could not be accounted for by the random errors in the measurements. The methods avoid the problems associated with pressurized cylinders. Both methods have merit and have found a place in instrument calibration work.

Evans, A., Jr.↗

Note: Binding energy scale calibration of electron spectrometers for photoelectron spectroscopy using a single sample

The feasibility of calibrating the binding energy scale for photoelectron spectroscopy using a single sample without sputter cleaning was investigated. By measuring the Fermi level of a Au film with both monochromatic Al K{alpha} (h{nu}= 1486.7 eV) and He I{alpha} (h{nu}= 21.22 eV), the binding energy scale was simply and accurately calibrated. This method is found to yield binding energy values for the Cu 2p{sub 3/2}, Ag 3d{sub 5/2}, and Au 4f{sub 7/2} peaks that agree with the standard tabulated values defined in International Organization for Standardization 15472 to within {+-}0.02 eV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Use of Proportional Counters for Yield Measurement in Extremely Short Pulses of Fast Neutrons: Counting Statistics and Absolute Calibration

A method for absolute calibration of proportional counters for pulsed fast neutrons is presented. The method is based on the use of an isotopic standard source and development of a model for counting detected events from area of a signal compounded by single piled up neutron pulses. Effects of detection counting statistics and electrical background noise are also considered.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of PuO 2 film thickness by electron probe microanalysis (EPMA) calibration curve method

Plutonium (Pu) surfaces are highly reactive toward oxygen containing species and, therefore, invariably covered with oxides (e.g. PuO 2 ) during transport and handling. The actual thickness of the surface oxide may dictate if a plutonium part is suitable for a certain application. As a result, a cost-effective, quick, non-destructive, yet reliable means to measure the oxide layer thickness formed on Pu samples is desirable. In this study, the cross-sections of a series of room temperature grown oxides on Pu samples were trenched by focus ion beam (FIB) then observed by scanning electron microscopy (SEM) to measure the surface oxide thicknesses, which were then combined with the corresponding oxygen k-ratios provided by electron probe microanalysis (EPMA) to form calibration curves. Oxide thickness measurements for the calibration curves were made on samples within the typical SEM observable range for PuO 2 (35–400 nm). The portion of the calibration curve in the thinner oxide region (<35 nm) were approximated via Pouchou and Pichoir’s Φ(ρz) theory. Two specimens with micrometer-thick PuO 2 standards (one formed at room temperature and the other at higher temperature with a higher level of crystallinity) were made for the k-ratios in this study, allowing EPMA users to choose the standard that best suits their needs. If the surface corrosion is known to be PuO 2 (from the environment in which the Pu sample is stored) or if the stoichiometry of the surface oxide is confirmed by a preliminary/compliment technique, these calibration curves allow EPMA users to quickly and efficiently determine PuO 2 thicknesses from the measured oxygen k-ratios of their samples. The methodology presented in this study can also be used as a template for creating calibration curves for oxides grown on other actinides.

36 MATERIALS SCIENCE↗

Calibration and operational data for a compact photodiode detector useful for monitoring the location of moving sources of positron emitting radioisotopes

D-Pace has developed a compact cost-effective gamma detector system based on technology licensed from TRIUMF. These photodiode detectors are convenient for detecting the presence of positron emitting radioisotopes, particularly for the case of transport of radioisotopes from a PET cyclotron to hotlab, or from one location to another in an automated radiochemistry processing unit. This paper describes recent calibration experiments undertaken at the Turku PET Centre for stationary and moving sources of F18 and C11 in standard setups. The practical diagnostic utility of using several of these devices to track the transport of radioisotopes from the cyclotron to hotlab is illustrated. For example, such a detector system provides: a semi-quantitative indication of total activity, speed of transport, location of any activity lost en route and effectiveness of follow-up system flushes, a means of identifying bolus break-up, feedback useful for deciding when to change out tubing.

07 ISOTOPE AND RADIATION SOURCES↗

Calibration of helical tomotherapy machine using EPR/alanine dosimetry

Purpose: Current codes of practice for clinical reference dosimetry of high-energy photon beams in conventional radiotherapy recommend using a 10x10 cm{sup 2} square field, with the detector at a reference depth of 10 cm in water and 100 cm source to surface distance (SSD) (AAPM TG-51) or 100 cm source-to-axis distance (SAD) (IAEA TRS-398). However, the maximum field size of a helical tomotherapy (HT) machine is 40x5 cm{sup 2} defined at 85 cm SAD. These nonstandard conditions prevent a direct implementation of these protocols. The purpose of this study is twofold: To check the absorbed dose in water and dose rate calibration of a tomotherapy unit as well as the accuracy of the tomotherapy treatment planning system (TPS) calculations for a specific test case. Method: Both topics are based on the use of electron paramagnetic resonance (EPR) using alanine as transfer dosimeter between the Laboratoire National Henri Becquerel (LNHB) {sup 60}Co-{gamma}-ray reference beam and the Institut Curie's HT beam. Irradiations performed in the LNHB reference {sup 60}Co-{gamma}-ray beam allowed setting up the calibration method, which was then implemented and tested at the LNHB 6 MV linac x-ray beam, resulting in a deviation of 1.6% (at a 1% standard uncertainty) relative to the reference value determined with the standard IAEA TRS-398 protocol. Results: HT beam dose rate estimation shows a difference of 2% with the value stated by the manufacturer at a 2% standard uncertainty. A 4% deviation between measured dose and the calculation from the tomotherapy TPS was found. The latter was originated by an inadequate representation of the phantom CT-scan values and, consequently, mass densities within the phantom. This difference has been explained by the mass density values given by the CT-scan and used by the TPS which were not the true ones. Once corrected using Monte Carlo N-Particle simulations to validate the accuracy of this process, the difference between corrected TPS calculations and alanine measured dose values was then found to be around 2% (with 2% standard uncertainty on TPS doses and 1.5% standard uncertainty on EPR measurements). Conclusion: Beam dose rate estimation results were found to be in good agreement with the reference value given by the manufacturer at 2% standard uncertainty. Moreover, the dose determination method was set up with a deviation around 2% (at a 2% standard uncertainty).

61 RADIATION PROTECTION AND DOSIMETRY↗

MODIS Solar Diffuser On-orbit Performance

MODIS is a key instrument for the NASA Earth Observing System (EOS), currently operated on both the Terra and Aqua missions. Each MODIS instrument has 20 reflective solar bands (RSBs) and 16 thermal emissive bands (TEBs). MODIS RSB on-orbit calibration is reflectance based using an on-board solar diffuser (SD). The SD bi-directional reflectance factors (BRFs) were characterized pre-launch using reference diffuser samples, which are traceable to NIST reflectance standards. The SD BRF on-orbit degradation (or change) is tracked by another onboard device, called the solar diffuser stability monitor (SDSM). The SDSM is operated during each scheduled SD calibration event, making alternate observations of direct sunlight and the diffusely reflected sunlight from the SD. The time series of the ratios of SDSM's SD view to its Sun view provide SD degradation information. This paper presents and compares the Terra and Aqua MODIS SD on-orbit performance. Results show that the SD on-orbit degradation depends on the amount of solar exposure of the SD plate. In addition, it is strongly wavelengthdependent, with a larger degradation rate at shorter wavelengths. For Terra MODIS, an SD door anomaly occurred in May 2003 that led to a decision to fix the door permanently at an "open" position. Since then, the SD degradation rate has significantly increased due to more frequent solar exposure. As expected, the SD on-orbit performance directly impacts the RSB calibration performance. The lessons learned from MODIS on-orbit calibration will provide useful insights into the development and operation of future SD calibration systems.

Xiong, Xiaoxiong↗

SU-E-T-641: Proton Range Measurements Using a Geometrically Calibrated Liquid Scintillator Detector

Purpose: The purpose of this work is to develop a geometric calibration method to accurately calculate physical distances within a liquid scintillator detector and to assess the accuracy, consistency, and robustness of proton beam range measurements when using a liquid scintillator detector system with the proposed geometric calibration process. Methods: We developed a geometric calibration procedure to accurately convert pixel locations in the camera frame into physical locations in the scintillator frame. To ensure accuracy, the geometric calibration was performed before each experiment. The liquid scintillator was irradiated with spot scanning proton beams of 94 energies in two deliveries. A CCD camera was used to capture the two-dimensional scintillation light profile of each of the proton energies. An algorithm was developed to automatically calculate the proton range from the acquired images. The measured range was compared to the nominal range to assess the accuracy of the detector. To evaluate the robustness of the detector between each setup, the experiments were repeated on three different days. To evaluate the consistency of the measurements between deliveries, three sets of measurements were acquired for each experiment. Results: Using this geometric calibration procedure, the proton beam ranges measured using the liquid scintillator system were all within 0.3mm of the nominal range. The average difference between the measured and nominal ranges was −0.20mm. The delivery-to-delivery standard deviation of the proton range measurement was 0.04mm, and the setup-to-setup standard deviation of the measurement was 0.10mm. Conclusion: The liquid scintillator system can measure the range of all 94 beams in just two deliveries. With the proposed geometric calibration, it can measure proton range with sub-millimeter accuracy, and the measurements were shown to be consistent between deliveries and setups. Therefore, we conclude that the liquid scintillator system provides a reliable and convenient tool for proton range measurement. This project was supported in part by award number CA182450 from the National Cancer Institute.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-T-246: MU Model Implementation for a Passively Scattered Proton Beam: Inclusion of the Bolus Gap and Nozzle Extension Factors

Purpose: To develop and implement an MU model for a passively scattered proton beam, and eliminate the need for patient specific calibrations for field sizes from 3cm to 15cm. This would enable consistent and timely calibrations for a wide variety of patient portals, streamlining the treatment process. Methods: Measurements were initially made using a Standard Imaging A-16 ion chamber and a modified water tank to determine the bolus gap factors (BGF) for multiple combinations of aperture size, bolus thickness, and air gap. The BGF was then separated into two component factors: the bolus thickness factor (BTF) and the nozzle extension factor (NEF). Polynomial curves were generated using the measured data to produce BTF tables for air gaps from 0cm to 30cm and for bolus thicknesses from 0cm to 10cm, and NEF tables for the full range of clinically used nozzle extensions. Additionally, data tables were created for every factor that affects beam output in the MU model. The MUs were then modeled for 487 patient portals and retrospectively compared to the MUs generated from the physical calibrations previously performed. Results: Of the 487 patient portals tested, 100% of the portals used for the comparison were within 2.5% from the MUs generated using a physical calibration, and 95.9% of the MU model portals tested were within 2%. The patient portals tested had field sizes ranging from 2.1cm to 10.1cm, with air gaps from 2cm to 25cm. Output factors for field sizes below 3cm with irregularly shaped fields demonstrated inconsistent results and will be further studied. Conclusion: The most problematic output factor, the BGF, was modeled accurately and consistently using the lowest order polynomial curve fits and interpolation between measured data. The study results demonstrate the robustness of the MU model and the potential for saving valuable personnel and beam time.

07 ISOTOPE AND RADIATION SOURCES↗