Search NASA⌕ Search

SEARCH · Search NASA

Results for “Calibration methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,783 records · Page 99

Bayesian Optimized Deep Ensemble for Uncertainty Quantification of Deep Neural Networks: a System Safety Case Study on Sodium Fast Reactor Thermal Stratification Modeling

Deep neural networks (DNNs) are increasingly important to scientific computing and engineering system simulations. Accurate uncertainty quantification (UQ) for DNNs is critical in safety-sensitive engineering domains. Traditional Deep Ensemble (DE) methods, while easy to implement, frequently suffer from poorly calibrated uncertainty estimates and limited predictive accuracy due to reliance on fixed architectures with varied weight initializations. To address these issues, we introduce a workflow that combines Bayesian Optimization (BO) and DE. The workflow is modular, scalable, and integrates parallel BO initialized with Sobol sequences to individually optimize the hyperparameters of each ensemble member. This method enhances ensemble diversity, improves predictive accuracy, and provides reliable uncertainty estimates. We evaluate the proposed BODE approach in a sodium fast reactor thermal stratification modeling case study, where we used a densely connected convolutional neural network to predict turbulent viscosity during the reactor transient with consideration of data noise. We benchmark its performance against several optimization approaches, including baseline deep ensemble, evolutionary algorithm-optimized ensemble, ensemble formed via random search combined with greedy selection, and a BO ensemble using random initialization. Here, our results demonstrate superior performance of the developed BODE approach. In noise-free scenarios, BODE notably reduces incorrect aleatoric uncertainty and significantly enhances predictive accuracy. Under conditions of 5% and 10% Gaussian noise, BODE adaptively quantifies uncertainty proportional to data noise, achieving up to an 80% reduction in root mean square error compared to baseline methods and producing well-calibrated prediction intervals.

Bayesian optimization↗

BEYOND THE MAIN SEQUENCE: TESTING THE ACCURACY OF STELLAR MASSES PREDICTED BY THE PARSEC EVOLUTIONARY TRACKS

Characterizing the physical properties of exoplanets and understanding their formation and orbital evolution requires precise and accurate knowledge of their host stars. Accurately measuring stellar masses is particularly important because they likely influence planet occurrence and the architectures of planetary systems. Single main-sequence stars typically have masses estimated from evolutionary tracks, which generally provide accurate results due to their extensive empirical calibration. However, the validity of this method for subgiants and giants has been called into question by recent studies, with suggestions that the masses of these evolved stars could have been overestimated. We investigate these concerns using a sample of 59 benchmark evolved stars with model-independent masses (from binary systems or asteroseismology) obtained from the literature. We find very good agreement between these benchmark masses and the ones estimated using evolutionary tracks. The average fractional difference in the mass interval ∼0.7–4.5 M{sub ⊙} is consistent with zero (−1.30 ± 2.42%), with no significant trends in the residuals relative to the input parameters. A good agreement between model-dependent and -independent radii (−4.81 ± 1.32%) and surface gravities (0.71 ± 0.51%) is also found. The consistency between independently determined ages for members of binary systems adds further support for the accuracy of the method employed to derive the stellar masses. Taken together, our results indicate that determination of masses of evolved stars using grids of evolutionary tracks is not significantly affected by systematic errors, and is thus valid for estimating the masses of isolated stars beyond the main sequence.

79 ASTRONOMY AND ASTROPHYSICS↗

Poster — Thur Eve — 42: Radiochromic film calibration for low-energy seed brachytherapy dose measurement

The purpose of this study was to investigate the accuracy of radiochromic film calibration procedures used in external beam radiotherapy when applied to I-125 brachytherapy sources delivering higher doses, and to determine any necessary modifications to achieve similar accuracy in absolute dose measurements. GafChromic EBT3 film was used to measure radiation doses upwards of 35 Gy from 6 MV, 75 kVp and (∼28 keV) I-125 photon sources. A custom phantom was used for the I-125 irradiations to obtain a larger film area with nearly constant dose to reduce the effects of film heterogeneities on the optical density (OD) measurements. RGB transmission images were obtained with an Epson 10000XL flatbed scanner, and calibration curves relating OD and dose using a rational function were determined for each colour channel and at each energy using a non-linear least square minimization method. Differences found between the 6 MV calibration curve and those for the lower energy sources are large enough that 6 MV beams should not be used to calibrate film for low-energy sources. However, differences between the 75 kVp and I-125 calibration curves were quite small; indicating that 75 kVp is a good choice. Compared with I-125 irradiation, this gives the advantages of lower type B uncertainties and markedly reduced irradiation time. To obtain high accuracy calibration for the dose range up to 35 Gy, two-segment piece-wise fitting was required. This yielded absolute dose measurement accuracy above 1 Gy of ∼2% for 75 kVp and ∼5% for I-125 seed exposures.

60 APPLIED LIFE SCIENCES↗

Cholesky-based experimental design for Gaussian process and kernel-based emulation and calibration.

Gaussian processes and other kernel-based methods are used extensively to construct approximations of multivariate data sets. The accuracy of these approximations is dependent on the data used. This paper presents a computationally efficient algorithm to greedily select training samples that minimize the weighted L p error of kernel-based approximations for a given number of data. The method successively generates nested samples, with the goal of minimizing the error in high probability regions of densities specified by users. The algorithm presented is extremely simple and can be implemented using existing pivoted Cholesky factorization methods. Training samples are generated in batches which allows training data to be evaluated (labeled) in parallel. For smooth kernels, the algorithm performs comparably with the greedy integrated variance design but has significantly lower complexity. Numerical experiments demonstrate the efficacy of the approach for bounded, unbounded, multi-modal and non-tensor product densities. We also show how to use the proposed algorithm to efficiently generate surrogates for inferring unknown model parameters from data using Bayesian inference.

97 MATHEMATICS AND COMPUTING↗

Application of calibration masks to TV vidicon tube

Photographic application method devised for overlaying test pattern masks on TV camera vidicon tubes prints the mask within 0.0076 cm of the vertical and horizontal center lines of the tube face. Entire process, including mask fabrication and alignment procedure, requires less than 10 minutes.

Brawner, E. L.↗

Concepts for a theoretical and experimental study of lifting rotor random loads and vibrations. Phase 5C: Development of experimental methods

Test equipment which was built and the calibration tests are described. The test equipment consists of a two-bladed rotor of 16-in. diameter, the blades of which are elastically hinged in flapping. The feathering shaft of the blades can be harmonically rotated with the help of a cam mechanism located inside the hollow rotor shaft. The frequency range measured in the rotating system can be adjusted between 0 and 80 cps and the rotor speed between 0 and 40 cps. The test equipment is for measuring the flapping response of the blades to harmonic feathering excitation.

Hohenemser, K. H.↗

STADAN antenna gain calibration using radio stars

An antenna gain measurement method was developed which utilizes a signal emitted from a radio star to determine absolute antenna gain at 136 MHz and 400 MHz for antennas in the STADAN network. An error analysis of the radio star method shows that the overall standard deviation uncertainty in antenna gain is + or - 0.6 db (1 sigma).

Taylor, R. E.↗

Self-calibrating models for dynamic monitoring and diagnosis

A method for automatically building qualitative and semi-quantitative models of dynamic systems, and using them for monitoring and fault diagnosis, is developed and demonstrated. The qualitative approach and semi-quantitative method are applied to monitoring observation streams, and to design of non-linear control systems.

Kuipers, Benjamin↗

Results of the Calibration of the Delays of Earth Stations for TWSTFT Using the VSL Satellite Simulator Method

Two-way satellite time and frequency transfer (TWSTFT) is the most accurate and precise method of comparing two remote clocks or time scales. The accuracy obtained is dependent on the accuracy of the determination of the non-reciprocal delays of the transmit and the receive paths. When the same transponders in the satellite at the same frequencies are used, then the non-reciprocity in the Earth stations is the limiting factor for absolute time transfer.

deJong, Gerrit↗

In-Orbit Instrument-Pointing Calibration Using the Moon as a Target

A method was developed for in-orbit measurement of the relative pointing of spectrometer channels, and the relationship between the spectrometer channels and the spacecraft coordinate system. In this innovation, individual scans of the Moon, from the three channels, were used to determine the position of the center of the Moon, with respect to channel-specific coordinates. Comparing the coordinates of the center of the Moon, obtained from individual channels, yields the relative pointing between the channels. Comparing the coordinates of the center of the Moon in one of the channels with the Moon ephemerides and with the spacecraft coordinate measurement, using the onboard star tracker, yields the relative orientation of the channel optical axes with respect to the spacecraft coordinates.

Abramovici, Alex↗

Assessing endothelial function and providing calibrated UFMD data using a blood pressure cuff

Methods and apparatus are provided for assessing endothelial function in a mammal. In certain embodiments the methods involve using a cuff to apply pressure to an artery in a subject to determine a plurality of baseline values for a parameter related to endothelial function as a function of applied pressure (P.sub.m); b) applying a stimulus to the subject; and applying external pressure P.sub.m to the artery to determine a plurality of stimulus-effected values for the parameter related to endothelial function as a function of applied pressure (P.sub.m); where the baseline values are determined from measurements made when said mammal is not substantially effected by said stimulus and differences in said baseline values and said stimulus-effected values provide a measure of endothelial function in said mammal.

60 APPLIED LIFE SCIENCES↗

Assessing endothelial function and providing calibrated UFMD data using a blood pressure cuff

Methods and apparatus are provided for assessing endothelial function in a mammal. In certain embodiments the methods involve using a cuff to apply pressure to an artery in a subject to determine a plurality of baseline values for a parameter related to endothelial function as a function of applied pressure (P.sub.m); b) applying a stimulus to the subject; and applying external pressure P.sub.m to the artery to determine a plurality of stimulus-effected values for the parameter related to endothelial function as a function of applied pressure (P.sub.m); where the baseline values are determined from measurements made when said mammal is not substantially effected by said stimulus and differences in said baseline values and said stimulus-effected values provide a measure of endothelial function in said mammal.

59 BASIC BIOLOGICAL SCIENCES↗

Assessing endothelial function and providing calibrated UFMD data using a blood pressure cuff

Methods and apparatus are provided for assessing endothelial function in a mammal. In certain embodiments the methods involve using a cuff to apply pressure to an artery in a subject to determine a plurality of baseline values for a parameter related to endothelial function as a function of applied pressure (Pm); b) applying a stimulus to the subject; and applying external pressure Pm to the artery to determine a plurality of stimulus-effected values for the parameter related to endothelial function as a function of applied pressure (Pm); where the baseline values are determined from measurements made when said mammal is not substantially effected by said stimulus and differences in said baseline values and said stimulus-effected values provide a measure of endothelial function in said mammal.

59 BASIC BIOLOGICAL SCIENCES↗

Transient Storage Model Parameter Optimization Using the Simulated Annealing Method

Hyporheic exchange in streams is critical to ecosystem functions such as nutrient cycling along river corridors, especially for slowly moving or small stream systems. The transient storage model (TSM) has been widely used for modeling of hyporheic exchange. TSM calibration, for hyporheic exchange, is typically used to estimate four parameters, including the mass exchange rate coefficient, the dispersion coefficient, stream cross-sectional area, and hyporheic zone cross-sectional area. Prior studies have raised concerns regarding the non-uniqueness of the inverse problem for the TSM, that is, the occurrence of different parameter vectors resulting in TSM solution that reproduces the observed in-stream tracer break through curve (BTC) with the same error. This leads to practical non-identifiability in determining the unknown parameter vector values even when global-optimal values exist, and the parameter optimization becomes practically non-unique. To address this problem, we applied the simulated annealing method to calibrate the TSM to BTCs, because it is less susceptible to local minima-induced non-identifiability. A hypothetical (or synthetic) tracer test data set with known parameters was developed to demonstrate the capability of the simulated annealing method to find the global minimum parameter vector, and it identified the “hypothetically-true” global minimum parameter vector even with input data that were modified with up to 10% noise without increasing the number of iterations required for convergence. The simulated annealing TSM was then calibrated using two in-stream tracer tests conducted in East Fork Poplar Creek, Tennessee. In conclusion, simulated annealing was determined to be appropriate for quantifying the TSM parameter vector because of its search capability for the global minimum parameter vector.

54 ENVIRONMENTAL SCIENCES↗

Parameter Calibration of GTN Damage Model and Formability Analysis of 22MnB5 in Hot Forming Process

Hot forming of high strength steel at elevated temperatures is an attractive technology to achieve the lightweight of vehicle body. The mechanical behavior of boron steel 22MnB5 strongly depends on the variation of temperature which makes the process design more difficult. In this paper, the Gurson–Tvergaard–Needleman (GTN) model is used to study the formability of 22MnB5 sheet at different temperatures. Firstly, the rheological behavior of 22MnB5 is analyzed through a series of hot tensile tests at a temperature range of 600-800 °C. Then, a detailed process to calibrate the damage parameters is given based on the response surface methodology and genetic algorithm method. The GTN model together with the damage parameters calibrated is then implemented to simulate the deformation and damage evolution of 22MnB5 in the process of high-temperature Nakazima test. The capability of the GTN model as a suitable tool to evaluate the sheet formability is confirmed by comparing experimental and calculated results. Finally, as a practical application, the forming limit diagram of 22MnB5 at 700 °C is constructed using the Nakazima simulation and Marciniak–Kuczynski (M–K) model, respectively. And the simulation integrated GTN model shows a higher reliability by comparing the predicted results of these two approaches with the experimental ones.

36 MATERIALS SCIENCE↗

Characterization of Neutron Emission Rates of Commercial 252 Cf Sources

Accurate knowledge of 252 Cf neutron emission rates is critical for modeling and fast-neutron experiments, yet commercial sources are often supplied without traceable calibration or uncertainty estimates. This report describes a method to characterize 252 Cf sources using a pulse-shape-discrimination (PSD) scintillator. The scintillator was efficiency-calibrated against a time-tagged 252 Cf fission chamber manufactured at ORNL over 40 years ago. Isotopic evolution of the calibration source was modeled using Bateman equations to account for changes in the effective average neutrons per fission at the time of measurement. The calibrated scintillator was then used to measure absolute emission rates of several commercial 252 Cf sources, revealing deviations of up to 12% from nominal manufacturer values. This methodology provides a practical approach for establishing uncertainty-quantified 252 Cf neutron emission rates, improving fidelity in simulations and supporting the accurate interpretation of measurements.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

PTT System Performance Evaluation in 3-D Imaging of Calibrated Defects: Pulsed Thermal Tomography Nondestructive Examination of Additively Manufactured Reactor Materials and Components

Research activity in this project is aimed at developing pulsed thermal tomography (PTT) architecture and algorithms for in-service non-destructive examination (NDE) of additively manufactured (AM) reactor components and materials. Recent advances in AM technology could allow cost-efficient fabrication of parts for operating reactors. However, because of stringent safety requirements, long-term performance of AM reactor components needs to be investigated before AM is widely accepted. Because of the complex shapes and significant surface roughness of components due to layer-by-layer welding process in AM, conventional methods might not be useful for in-service NDE of AM components. PTT is ideally suited for in-service NDE of AM metallic components because the method is non-contact, and offers high resolution #-D imaging of material flaws. The objective of this report is to provide initial evaluate of PTT performance sin detecting calibrated flaws in reactor structural materials. Preliminary COMSOL models were developed to conduct super computing simulations of PTT. In the experimental studies, high strength Stainless Steel 316 and Inconel 718 alloys were considered, as well as lower grade Stainless Steel 304, Nickel 200, and Hastelloy C276. Specimens investigated in this report consisted of approximately 1/4in-thick plates made out of these alloys using conventional manufacturing methods. The calibrated defects were created in the form of flat bottom holes (FBH) drilled in metallic plates. The diameters of FBH's varied from 1mm to 8mm, and their depths below the plate flat surface varied between 1mm and 6mm. The size of the smallest FBH was limited to 1mm because conventional mechanic drills were used for creating the holes. PTT imaging results have shown that 1mm-diameter FBH located 1mm and 2mm below the surface were detectable. Larger size FBH were detectable at greater depth. For example, 6mm-diameter FBH could be detected at 8mm depth. Image contrast varied slightly between the specimens, with the best reconstructions obtained in SS316 and C276 plates. In addition, a 2/3in-thick Inconel 718 nozzle plate produced with additive manufacturing method was imaged with PTT. It was shown that PTT can scan through the plate in approximately 20s. Several modes of 3-D data visualization were explored, including using ImageJ and MATLAB software packages.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Problems with the Baade-Wesselink method

The discrepancy noted in radii obtained by the Baade-Wesselink method when different colors are used to determine the effective temperatures is explored. The discrepancy is found to be due to an inconsistency in the applied temperature-color calibrations. The assumption of the maximum likelihood method that beta (the effective temperature + 0.1 times the bolometric correction) is a linear function of the color is valid for the B-V and V-I colors, but not for the V-R colors. It is suggested that the errors introduced by the nonlinearity in the relation between beta and the V-R colors will produce radii which are too large. The radii derived from the V-B colors appear to be too small.

Bohm-Vitense, E.↗