Search NASA⌕ Search

SEARCH · Search NASA

Results for “Compaction technologies”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,783 records · Page 99

Scintillating crystals for the Neutral Particle Spectrometer in Hall C at JLab

This report discusses the quality and performance of currently available PbWO crystals of relevance to high-resolution electromagnetic calorimetry, e.g. detectors for the Neutral Particle Spectrometer at Jefferson Lab or those planned for the Electron–Ion Collider. Since the construction of the Compact Muon Solenoid (CMS) at the Large Hadron Collider (LHC) and early PANDA (The antiProton ANnihilations at DArmstadt) electromagnetic calorimeter (ECAL) the worldwide availability of high quality PbWO 4 production has changed dramatically. We report on our studies of crystal samples from SICCAS/China and CRYTUR/Czech Republic that were produced between 2014 and 2019.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MAIA: A new detector concept for a 10 TeV muon collider

Muon colliders offer a compelling opportunity to explore the TeV scale and conduct precision tests of the Standard Model, all within a relatively compact geographical footprint. This paper introduces a new detector concept, MAIA (Muon Accelerator Instrumented Apparatus), optimized for $\sqrt{s}=10$ TeV $\mu\mu$ collisions. The detector features an all-silicon tracker immersed in a 5T solenoid field. High-granularity silicon-tungsten and iron-scintillator calorimeters surrounding the solenoid capture high-energy electronic and hadronic showers, respectively, and support particle-flow reconstruction. The outermost subsystem comprises an air-gap muon spectrometer, which enables standalone track reconstruction for high-momentum muons. The performance of the MAIA detector is evaluated in terms of differential particle reconstruction efficiencies and resolutions. Beam-induced background (BIB) simulations generated in FLUKA are overlaid with single particle gun samples to assess detector reconstruction capabilities under realistic experimental conditions. Even with BIB, reconstruction efficiencies exceed 95% for energetic tracks, photons, and neutrons in the central region of the detector. This paper outlines promising avenues of future work, including forward region optimization and opportunities for enhanced flavor/boosted object tagging, and addresses the technological assumptions needed to achieve the desired detector performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Advanced CMOS Reliability Update: Sub 20nm FinFET Assessment

Advances in FinFET design and fabrication enable manufacturing of denser, more compact integrated circuits (ICs) with substantially reduced leakage while shortening the channel-lengths. The same stress-induced leakage and breakdown degradation mechanisms that affect planar transistors also impact FinFET devices. Reliability concerns such as Bias Temperature Instability (BTI), Time Dependent Dielectric Breakdown (TDDB), and Hot Carrier Injection (HCI) become very important with changes to transistor geometry and fin sidewall crystal orientation. Recent testing has shown that FinFETs respond differently to radiation (radiation effects such as total ionizing dose) when compared to planar transistors. These reliability and radiation effects issues become very important when changing transistor geometry and scaling FinFETs towards smaller feature sizes (22-nm, 16-nm, 14- nm, 10-nm, and smaller critical dimensions). The comparable 2019 state of the art transistor densities in current high-volume manufacturing silicon-based foundries is 7-nm (ISMC, Samsung) and 10-nm (Intel) [www.anandtech.com,fuse.wikichip.org]. Released products include supporting components for the cellphone and commercial microprocessor markets respectively. Extensive development in the foundry industry is driving to a 5-nm technology node in late 2020.

47 OTHER INSTRUMENTATION↗

Single-shot complete spatiotemporal measurement of terawatt laser pulses

In this work, we demonstrate, for the first time, a single-shot, complete spatiotemporal measurement of pulses from a terawatt-scale, multi-stage-amplified, low repetition-rate laser source. The ultrashort pulse electric field, E(x,y,z,t), is spatiotemporally complex due to distortions that accrue from multiple chirped-pulse amplifiers, which requires a complete characterization. Meanwhile, the instability of the laser source introduces field profiles that vary significantly from pulse to pulse, which, together with the low repetition-rate (15 shots/hour), requires the use of a single-shot measurement technique. To accomplish the measurements, we used a wavelength-multiplexed, digital-holographic technique called Spatially and Temporally Resolved Intensity and Phase Evaluation Device: Full Information from a Single Hologram, specially tailored to measure picosecond pulses at a wavelength of about 1 μm. Specifically, individual pulses from the compact multipulse terawatt laser were measured, with up to 0.3 J per shot of energy and ~2 ps pulse durations, at 1052 nm. With these measurements, we characterized several major spatiotemporal distortions that affect the peak intensity at the laser focus, as well as the pulse-shape instability on a shot-to-shot basis. Our technique allows detailed diagnosis of laser pulses (especially high-order spatiotemporal distortions) and provides straightforward four-dimensional animations of pulse propagation to a focus.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Electrically switchable metallic polymer metasurface device with gel polymer electrolyte

Abstract We present an electrically switchable, compact metasurface device based on the metallic polymer PEDOT:PSS in combination with a gel polymer electrolyte. Applying square-wave voltages, we can reversibly switch the PEDOT:PSS from dielectric to metallic. Using this concept, we demonstrate a compact, standalone, and CMOS compatible metadevice. It allows for electrically controlled ON and OFF switching of plasmonic resonances in the 2–3 µm wavelength range, as well as electrically controlled beam switching at angles up to 10°. Furthermore, switching frequencies of up to 10 Hz, with oxidation times as fast as 42 ms and reduction times of 57 ms, are demonstrated. Our work provides the basis towards solid state switchable metasurfaces, ultimately leading to submicrometer-pixel spatial light modulators and hence switchable holographic devices.

36 MATERIALS SCIENCE↗

A compact neutron spectrometer system

A portable neutron spectrometer, nSpec, has been developed for passive interrogation of fast neutrons ( 1 MeV) from neutron sources. The design of the system includes four EJ-301 liquid scintillation cells, a custom stand, and tungsten caps for gamma-ray shielding. Data acquisition settings were optimized to provide a dynamic range of up to > 15 MeV neutron energy. Additionally, the detector response matrix was characterized using a time-of-flight method based on gamma-ray tagged neutron emission from 252 Cf. The spectrum unfolding was characterized using measured and simulated spectra of AmBe and 252 Cf with the GRAVEL and MLEM methods. Monte Carlo methods were used to examine the uncertainty propagation and determine sufficient counts for a measurement.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design of a multichannel photonic crystal dielectric laser accelerator

To be useful for most scientific and medical applications, compact particle accelerators will require much higher average current than enabled by current architectures. For this purpose, we propose a photonic crystal architecture for a dielectric laser accelerator, referred to as a multi-input multi-output silicon accelerator (MIMOSA), that enables simultaneous acceleration of multiple electron beams, increasing the total electron throughput by at least 1 order of magnitude. To achieve this, we show that the photonic crystal must support a mode at the Γ point in reciprocal space, with a normalized frequency equal to the normalized speed of the phase-matched electron. We show that the figure of merit of the MIMOSA can be inferred from the eigenmodes of the corresponding infinitely periodic structure, which provides a powerful approach to design such devices. Additionally, we extend the MIMOSA architecture to electron deflectors and other electron manipulation functionalities. These additional functionalities, combined with the increased electron throughput of these devices, permit all-optical on-chip manipulation of electron beams in a fully integrated architecture compatible with current fabrication technologies, which opens the way to unconventional electron beam shaping, imaging, and radiation generation.

43 PARTICLE ACCELERATORS↗

Acoustic mapping by picosecond ultrasonics for elastic property measurement: Experimental demonstration on a TRISO fuel compact

Picosecond ultrasonics has been demonstrated on a tristructural isotropic (TRISO) fuel compact to measure the elastic properties of each compact layer. This technique utilizes an ultrashort pump laser pulse to excite vibrations in a gold transducer film covering the surface of each component and a second probe laser pulse to record the resulting acoustic strain induced change in optical reflectance. From the damping of this film vibration, the acoustic reflection coefficient, which couples the elastic properties of the transducer film and the sample, can be obtained, enabling a calculation of the sample’s acoustic velocity and elastic modulus. Overall, results obtained from this method are consistent with known values of elastic moduli, namely that the SiC coating is the stiffest component of the compact while the carbonaceous matrix is the most compliant. Nanoindentation was conducted as a benchmark technique on the same sample and shows satisfactory agreement with the results of picosecond ultrasonics. Compared to other methods like nanoindentation, picosecond ultrasonics is multimodal with a capability of measuring several key properties simultaneously and has potentials to be coupled into optical fibers for remote sensing. Thus, these demonstration measurements reveal the methodology to be a promising candidate for in-situ and high-throughput optical characterizations of nuclear materials.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Dual wavelength imaging of a scrape-off layer in an advanced beam-driven field-reversed configuration

A dual wavelength imaging system has been developed and installed on C-2U to capture 2D images of a He jet in the Scrape-Off Layer (SOL) of an advanced beam-driven Field-Reversed Configuration (FRC) plasma. The system was designed to optically split two identical images and pass them through 1 nm FWHM filters. Dual wavelength images are focused adjacent on a large format CCD chip and recorded simultaneously with a time resolution down to 10 μs using a gated micro-channel plate. The relatively compact optical system images a 10 cm plasma region with a spatial resolution of 0.2 cm and can be used in a harsh environment with high electro-magnetic noise and high magnetic field. The dual wavelength imaging system provides 2D images of either electron density or temperature by observing spectral line pairs emitted by He jet atoms in the SOL. A large field of view, combined with good space and time resolution of the imaging system, allows visualization of macro-flows in the SOL. First 2D images of the electron density and temperature observed in the SOL of the C-2U FRC are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nonlinear saturation of ballooning modes in stellarators

Ballooning mode saturation is investigated in realistic stellarator configurations using the flux tube approach of Ham et al (2018 Plasma Phys. Control. Fusion 60 075017), Ham et al (2016 Phys. Rev. Lett. 116 235001). The method is adapted to account for the lack of exact force balance in stellarator equilibrium solvers that assume existence of nested flux surfaces. A variational approach for calculating flux tube energy is developed to overcome this force error problem in stellarator numerical equilibria. Saturated (equilibrium) flux tube states that cross 10%–20% of the plasma minor radius are shown to exist for linearly ballooning unstable profiles. It is shown that several features of the displaced flux tube structure in a full nonlinear MHD simulation of Wendelstein 7X are reproduced by our model. Saturated states are found in a compact stellarator equilibrium close but below the marginal ballooning linear instability, i.e. the unperturbed equilibrium is metastable. This suggests that edge-localized-mode-like explosive MHD behavior may be possible in stellarators.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Detecting gravitational signatures of dark matter with atom gradiometers

We study the purely gravitational signatures of dark matter from the ultralight to the ultraheavy mass range in proposed long-baseline atom gradiometers, focusing on terrestrial designs, such as AION-km and MAGIS-km, as well as space-based concepts, such as MAGIS-space, AEDGE and AEDGE+. Due to its exceptional acceleration sensitivity and depending on astrophysical backgrounds, a detector similar to AEDGE+ could detect a dark matter subcomponent which constitutes 𝒪⁡(10%) of the local dark matter energy density and is populated by compact clumps of mass between 10 6 kg and 10 10 kg (10 −25 ⁢𝑀⊙ ≲ 𝑀 ≲10 −21⁢ 𝑀⊙) in an otherwise unexplored region of dark matter model space. Furthermore, because the gravitational observable depends on the relative gravitational time delay measured by spatially separated atomic clouds, we find that atom gradiometers are parametrically more sensitive than laser interferometers, such as LIGO and LISA, to fast-oscillating spacetime perturbations sourced by energy density and pressure fluctuations of ultralight dark matter. Depending on astrophysical backgrounds, a detector akin to AEDGE+ could probe a DM overdensity of 𝒪⁡(10) times the local dark matter energy density for masses 𝑚 ≲10 −17 eV.

79 ASTRONOMY AND ASTROPHYSICS↗

Process Intensification for Nanostructure Aluminum Extrusions

A new technology called Shear Assisted Processing and Extrusion (ShAPE™), pioneered at the Pacific Northwest National Laboratory (PNNL), has the potential to revolutionize the US extrusion industry. Maturation of the ShAPE™ process would create a new cross cutting US manufacturing technology that advances three key the objectives within AMO; namely, nanomaterials processing, process intensification, and materials for extreme and harsh environments. PNNL and SCM Metals Products, Inc. (SCM), a division of Kymera International, will collaborate to mature the ShAPE™ extrusion process beyond TRL 3 to increase the likelihood of its adoption by industry. PNNL’s custom (one-of-a-kind in the world) ShAPE™ machine will be used to extrude round rods of high strength aluminum alloy feedstock powder provided by SCM. As proof-of-concept, PNNL has previously extruded 5 mm diameter rods with SCM aluminum alloy powder AL-12.4TM. This project aims to scale up the process to a diameter of 25 mm while retaining the excellent mechanical properties achieved for the 5 mm diameter rods. The degree of process intensification with ShAPE™ will also be estimated. The primary objectives of this project are as follows. 1) Fabricate 25 mm diameter nanostructured extrusions in bulk, directly from AL-12.4TM aluminum alloy powder without the need for canning, degassing, compaction, and other intermediate steps typical of powder metallurgy extrusion. 2) Achieve a microstructure with an ultrafine grained (UFG <1 µm) aluminum matrix having refined and homogenously distributed nanoscale second phases. 3) Show that the ram force can be significantly reduced compared to conventional powder metallurgy extrusion of the same material and estimate the extent of process intensification that may be possible with ShAPE™. 4) Demonstrate improved high-temperature mechanical properties compared to conventional extrusion of the same material. The following tasks will be undertaken to achieve these objectives. PNNL will develop the die set and process parameters necessary to fabricate Al-12.4TM extrusions with a 25 mm diameter. Microstructural analysis will be performed by PNNL while mechanical testing will be conducted by SCM. With information learned from the process development and characterization, PNNL will perform an estimate of the degree of process intensification that may be possible with ShAPE™.

42 ENGINEERING↗

A Common Calibration Source Framework for Fully-Polarimetric and Interferometric Radiometers

Two types of microwave radiometry--synthetic thinned array radiometry (STAR) and fully-polarimetric (FP) radiometry--have received increasing attention during the last several years. STAR radiometers offer a technological solution to achieving high spatial resolution imaging from orbit without requiring a filled aperture or a moving antenna, and FP radiometers measure extra polarization state information upon which entirely new or more robust geophysical retrieval algorithms can be based. Radiometer configurations used for both STAR and FP instruments share one fundamental feature that distinguishes them from more 'standard' radiometers, namely, they measure correlations between pairs of microwave signals. The calibration requirements for correlation radiometers are broader than those for standard radiometers. Quantities of interest include total powers, complex correlation coefficients, various offsets, and possible nonlinearities. A candidate for an ideal calibration source would be one that injects test signals with precisely controllable correlation coefficients and absolute powers simultaneously into a pair of receivers, permitting all of these calibration quantities to be measured. The complex nature of correlation radiometer calibration, coupled with certain inherent similarities between STAR and FP instruments, suggests significant leverage in addressing both problems together. Recognizing this, a project was recently begun at NASA Goddard Space Flight Center to develop a compact low-power subsystem for spaceflight STAR or FP receiver calibration. We present a common theoretical framework for the design of signals for a controlled correlation calibration source. A statistical model is described, along with temporal and spectral constraints on such signals. Finally, a method for realizing these signals is demonstrated using a Matlab-based implementation.

Kim, Edward J.↗

The passivity of low-temperature carburized austenitic stainless steel AISI-316L in a simulated boiling-water-reactor environment

The passive film on low-temperature-carburized AISI-316L austenitic stainless steel was studied in an oxygenated, simulated boiling-water-reactor environment with normal water chemistry. The microstructure was studied using scanning electron microscopy, grazing-incidence X-ray diffractometry, Auger electron spectroscopy, X-ray energy-dispersive spectroscopy, and transmission electron microscopy. For non-surface engineered AISI-316L, three distinct layers were observed after exposure: an outer layer of larger nickel-oxide enriched particles with the spinel structure, an intermediate layer of small Cr-oxide-enriched hematite particles, and a compact inner layer of Cr-enriched oxide also having the spinel structure. Exposure of low-temperature-carburized AISI-316L, in contrast, resulted in only two distinct layers. These layers did not include a compact Cr-rich inner layer. Instead, the innermost layer consisted of an oxide with the spinel structure that was a mixture of Fe, Cr and Ni oxide. The outer layer on the low-temperature-carburized specimen consisted of large loosely stacked particles with the spinel structure of mixed composition. In addition to passive-film characterization, the corrosion rate was studied by monitoring mass loss. Finally, after 500 h of immersion, the mass changes measured were relatively low for all specimens indicating good adhesion and low oxidation rates.

36 MATERIALS SCIENCE↗

The Spherical Tokamak for Energy Production: theme issue introduction

This theme issue collects together papers summarising the conceptual design of the Spherical Tokamak for Energy Production (STEP). In 2019, the UK government funded the first design stages of a prototype fusion powerplant based on a compact toroidal geometry, called STEP. The primary technical aims of STEP are to produce net energy, to be self-sufficient in tritium fuel and to demonstrate a maintenance regime that would extrapolate to appropriate availability for commercial powerplants. After 5 years and over 1000 person-years of detailed scientific and engineering conceptual design, this theme issue acts as a compendium of the current design basis for STEP, noting that this is a snapshot in time and that the design will continue to evolve. This article is part of the theme issue ‘Delivering Fusion Energy – The Spherical Tokamak for Energy Production (STEP)’.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A Charge Sensitive Pre-Amplifier for Smart Point-of-Care Devices Employing Polymer Based Lab-on-a-Chip

With increasing emphasis on implantable and portable medical devices, low-power, small-chip-area sensor readout system realized in lab-on-a-chip (LOC) platform is gaining more and more importance these days. The main building blocks of the LOC system include a front-end transducer that generates an electrical signal in response to the presence of an analyte of interest, signal processing electronics to process the signal to comply with a specific transmission protocol and a low-power transmitter, all realized in a single integrated circuit platform. Low power consumption and compactness of the components are essential requirements of the LOC system. This paper presents a novel charge sensitive pre-amplifier developed in a standard 180-nm CMOS process suitable for implementing in an LOC platform. The pre-amplifier converts the charge generated by a pyroelectric transducer into a voltage signal, which provides a measurement of the temperature variation in biological fluids. The proposed design is capable of providing 0.8-mV/pC gain while consuming only 2.1 μW of power. Finally, the pre-amplifier composed of integrated components occupies an area of 0.038 mm 2 .

36 MATERIALS SCIENCE↗

Elongated Fullerene Unlocks Oxygen-Resistant Perovskite Solar Minimodules

State-of-the-art encapsulation cannot prevent the permeation of oxygen into perovskite solar cells (PSCs). Here, we report the finding that p-i-n structured PSCs degrade quickly under oxygen exposure. Oxidation of C60, rather than perovskites, dominates the degradation. Chemical absorption of oxygen by C60 is identified, which impairs its electron transport property. We modify the electron transport layers to address the instability under oxygen exposure. The elongated fullerene C70 is found to react with oxygen orders of magnitude slower than C60. In combination with a compact SnO2 buffer fabricated by atomic layer deposition, which can slow down the oxygen diffusion, the resulting unencapsulated PSCs with C70 retained 90% of their initial efficiency after 1-sun illumination in pure oxygen for 1,200 h at 70 degrees C, improving stability by hundreds of times. Testing of unencapsulated perovskite minimodules of different perovskite compositions with C70 gives extrapolated lifetimes of 17-41 years at 50 degrees C.

14 SOLAR ENERGY↗

Note: Autocollimation with ultra-high resolution and stability using telephoto objective together with optical enlargement and beam drift compensation

An autocollimation (AC) setup with ultra-high resolution and stability for micro-angle measurement is presented. The telephoto objective, which is characterized in long focal length at a compact structure size, and the optical enlargement unit, which can magnify the image displacement to improve its measurement resolution and accuracy, are used to obtain an ultra-high measurement resolution of the AC. The common-path beam drift compensation is used to suppress the drift of measurement results, which is evident in the high-resolution AC, thus to obtain a high measurement stability. Experimental results indicate that an effective resolution of better than 0.0005 arc sec (2.42 nrad) over a measurement range of ±30 arc sec and a 2-h stability of 0.0061 arc sec (29.57 nrad) can be achieved.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗