Search NASA⌕ Search

SEARCH · Search NASA

Results for “Data fitting”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,783 records · Page 99

Test of a General Formula for Black Hole Gravitational Wave Kicks

Although the gravitational wave kick velocity in the orbital plane of coalescing black holes has been understood for some time, apparently conflicting formulae have been proposed for the dominant outof- plane kick, each a good fit to different data sets. This is important to resolve because it is only the out-of-plane kicks that can reach more than 500 km s-l and can thus eject merged remnants from galaxies. Using a different ansatz for the out-of-plane kick, we show that we can fit almost all existing data to better than 5%. This is good enough for any astrophysical calculation and shows that the previous apparent conflict was only because the two data sets explored different aspects of the kick parameter space.

van Meter, James R.↗

Assessment of Postflight Locomotor Performance Utilizing a Test of Functional Mobility: Strategic and Adaptive Responses

Space flight induces adaptive modification in sensorimotor function, allowing crewmembers to operate in the unique microgravity environment. This adaptive state, however, is inappropriate for a terrestrial environment. During a re-adaptation period upon their return to Earth, crewmembers experience alterations in sensorimotor function, causing various disturbances in perception, spatial orientation, posture, gait, and eye-head coordination. Following long duration space flight, sensorimotor dysfunction would prevent or extend the time required to make an emergency egress from the vehicle; compromising crew safety and mission objectives. We are investigating two types of motor learning that may interact with each other and influence a crewmember's ability to re-adapt to Earth's gravity environment. In strategic learning, crewmembers make rapid modifications in their motor control strategy emphasizing error reduction. This type of learning may be critical during the first minutes and hours after landing. In adaptive learning, long-term plastic transformations occur, involving morphological changes and synaptic modification. In recent literature these two behavioral components have been associated with separate brain structures that control the execution of motor strategies: the strategic component was linked to the posterior parietal cortex and the adaptive component was linked to the cerebellum (Pisella, et al. 2004). The goal of this paper was to demonstrate the relative contributions of the strategic and adaptive components to the re-adaptation process in locomotor control after long duration space flight missions on the International Space Station (ISS). The Functional Mobility Test (FMT) was developed to assess crewmember s ability to ambulate postflight from an operational and functional perspective. Sixteen crewmembers were tested preflight (3 sessions) and postflight (days 1, 2, 4, 7, 25) following a long duration space flight (approx 6 months) on the ISS. We have further analyzed the FMT data to characterize strategic and adaptive components during the postflight readaptation period. Crewmembers walked at a preferred pace through an obstacle course set up on a base of 10 cm thick medium density foam (Sunmate Foam, Dynamic Systems, Inc., Leicester, NC). The 6.0m X 4.0m course consisted of several pylons made of foam; a Styrofoam barrier 46.0cm high that crewmembers stepped over; and a portal constructed of two Styrofoam blocks, each 31cm high, with a horizontal bar covered by foam and suspended from the ceiling which was adjusted to the height of the crewmember s shoulder. The portal required crewmembers to bend at the waist and step over a barrier simultaneously. All obstacles were lightweight, soft and easily knocked over. Crewmembers were instructed to walk through the course as quickly and as safely as possible without touching any of the objects on the course. This task was performed three times in the clockwise direction and three times in the counterclockwise direction that was randomly chosen. The dependent measures for each trial were: time to complete the course (seconds) and the number of obstacles touched or knocked down. For each crewmember, the time to complete each FMT trial from postflight days 1, 2, 4, 7 and 25 were further analyzed. A single logarithmic curve using a least squares calculation was fit through these data to produce a single comprehensive curve (macro). This macro curve composed of data spanning 25 days, illustrates the re-adaptive learning function over the longer time scale term. Additionally, logarithmic curves were fit to the 6 data trials within each individual post flight test day to produce 5 separate daily curves. These micro curves, produced from data obtained over the course of minutes, illustrates the strategic learning function exhibited over a relative shorter time scale. The macro curve for all subjects exhibited adaptive motor learning patterns over the 25 day period. Howev, 9/16 crewmembers exhibited significant strategic motor learning patterns in their micro curves, as defined by m > 1 in the equation of the line y=m*LN(x) +b. These data indicate that postflight recovery in locomotor function involves both strategic and adaptive mechanisms. Future countermeasures will be designed to enhance both recovery processes.

Warren, L. E.↗

Optimization of Error-Bounded Lossy Compression for Hard-to-Compress HPC Data

Since today’s scientific applications are producing vast amounts of data, compressing them before storage/transmission is critical. Results of existing compressors show two types of HPC data sets: highly compressible and hard to compress. In this work, we carefully design and optimize the error-bounded lossy compression for hard-tocompress scientific data. We propose an optimized algorithm that can adaptively partition the HPC data into best-fit consecutive segments each having mutually close data values, such that the compression condition can be optimized. Another significant contribution is the optimization of shifting offset such that the XOR-leading-zero length between two consecutive unpredictable data points can be maximized. We finally devise an adaptive method to select the best-fit compressor at runtime for maximizing the compression factor. We evaluate our solution using 13 benchmarks based on real-world scientific problems, and we compare it with 9 other state-of-the-art compressors. Experiments show that our compressor can always guarantee the compression errors within the user-specified error bounds. Most importantly, our optimization can improve the compression factor effectively, by up to 49% for hard-tocompress data sets with similar compression/decompression time cost.

97 MATHEMATICS AND COMPUTING↗

R-matrix Resolved Resonance Region Evaluation of 140,142 Ce

Oak Ridge National Laboratory completed the resolved resonance region (RRR) evaluation of the two most abundant cerium isotopes, 140 Ce (88.45%) and 142 Ce (11.11%), as requested by the US Nuclear Criticality Safety Program. These evaluations are based on recent high-resolution transmission and capture measurements performed on nat Ce and highly enriched 142 Ce samples at the JRC-Geel Linear Accelerator facility, as well as measured thermal constants available from the EXFOR database. Starting from the resonance parameters of the ENDF/B-VIII.0 library followed by a preliminary R-matrix analysis, an updated set of resonance parameters and corresponding covariance information were derived by fitting these measured data using the Reich–Moore approximation of the R -matrix theory, as implemented in the SAMMY code system. The 140 Ce RRR upper energy limit was kept at 200 keV, whereas the 142 Ce resonance region was extended from 13 to 26 keV. Updated statistical properties were obtained for the new evaluations and compared to those derived from the ENDF/B-VIII.0 nuclear data library. The new evaluation work improved some of the discrepancies found in previous work, such as the capture resonance integral and stellar Maxwellian-averaged cross sections. These integral quantities were mainly derived from the fit of the latest measured data, especially the neutron capture yield data for 142 Ce isotope.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Development of the FITS tools package for multiple software environments

The HEASARC is developing a package of general purpose software for analyzing data files in FITS format. This paper describes the design philosophy which makes the software both machine-independent (it runs on VAXs, Suns, and DEC-stations) and software environment-independent. Currently the software can be compiled and linked to produce IRAF tasks, or alternatively, the same source code can be used to generate stand-alone tasks using one of two implementations of a user-parameter interface library. The machine independence of the software is achieved by writing the source code in ANSI standard Fortran or C, using the machine-independent FITSIO subroutine interface for all data file I/O, and using a standard user-parameter subroutine interface for all user I/O. The latter interface is based on the Fortran IRAF Parameter File interface developed at STScI. The IRAF tasks are built by linking to the IRAF implementation of this parameter interface library. Two other implementations of this parameter interface library, which have no IRAF dependencies, are now available which can be used to generate stand-alone executable tasks. These stand-alone tasks can simply be executed from the machine operating system prompt either by supplying all the task parameters on the command line or by entering the task name after which the user will be prompted for any required parameters. A first release of this FTOOLS package is now publicly available. The currently available tasks are described, along with instructions on how to obtain a copy of the software.

Pence, W. D.↗

Estimation of {alpha}/{beta} for Late Rectal Toxicity Based on RTOG 94-06

Purpose: To estimate {alpha}/{beta}, the parameter ratio from the linear-quadratic (LQ) model, for Grade {>=}2 late rectal toxicity among patients treated on Radiation Therapy Oncology Group (RTOG) protocol 94-06; and to determine whether correcting the rectal dose-volume histogram (DVH) for differences in dose per fraction, based on the LQ model, significantly improves the fit to these data of the Lyman-Kutcher-Burman (LKB) normal-tissue complication probability (NTCP) model. Methods and Materials: The generalized LKB model was fitted to the Grade {>=}2 late rectal toxicity data in two ways: by using DVHs representing physical dose to rectum, and by using a modified approach in which dose bins in the rectal DVH were corrected for differences in dose per fraction using the LQ model, with {alpha}/{beta} estimated as an additional unknown parameter. The analysis included only patients treated with the same treatment plan throughout radiotherapy, so that the dose per fraction to each voxel of rectum could be determined from the DVH. The likelihood ratio test was used to assess whether the fit of the LQ-corrected model was significantly better than the fit of the LKB model based on physical doses to rectum. Results: The analysis included 509 of the 1,084 patients enrolled on RTOG 94-06. The estimate of {alpha}/{beta} from the LQ-corrected LKB model was 4.8 Gy, with 68% confidence interval 0.6 Gy to 46 Gy. The fit was not significantly different from the fit of the LKB model based on physical dose to rectum (p = 0.236). Conclusions: The estimated fractionation sensitivity for Grade {>=}2 late rectal toxicity is consistent with values of {alpha}/{beta} for rectum found previously in human beings and in rodents. However, the confidence interval is large, and there is no evidence that LQ correction of the rectal DVH significantly changes the fit or predictions of the LKB model for this endpoint.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

NuSTAR unveils a Compton-thick type 2 quasar in MrK 34

We present Nuclear Spectroscopic Telescope Array (NuSTAR) 3-40 keV observations of the optically selected Type 2 quasar (QSO2) SDSS J1034+6001 or Mrk 34. The high-quality hard X-ray spectrum and archival XMM-Newton data can be fitted self-consistently with a reflection-dominated continuum and a strong Fe Kα fluorescence line with equivalent width >1 keV. Prior X-ray spectral fitting below 10 keV showed the source to be consistent with being obscured by Compton-thin column densities of gas along the line of sight, despite evidence for much higher columns from multiwavelength data. NuSTAR now enables a direct measurement of this column and shows that N {sub H} lies in the Compton-thick (CT) regime. The new data also show a high intrinsic 2-10 keV luminosity of L {sub 2-10} ∼ 10{sup 44} erg s{sup –1}, in contrast to previous low-energy X-ray measurements where L {sub 2-10} ≲ 10{sup 43} erg s{sup –1} (i.e., X-ray selection below 10 keV does not pick up this source as an intrinsically luminous obscured quasar). Both the obscuring column and the intrinsic power are about an order of magnitude (or more) larger than inferred from pre-NuSTAR X-ray spectral fitting. Mrk 34 is thus a 'gold standard' CT QSO2 and is the nearest non-merging system in this class, in contrast to the other local CT quasar NGC 6240, which is currently undergoing a major merger coupled with strong star formation. For typical X-ray bolometric correction factors, the accretion luminosity of Mrk 34 is high enough to potentially power the total infrared luminosity. X-ray spectral fitting also shows that thermal emission related to star formation is unlikely to drive the observed bright soft component below ∼3 keV, favoring photoionization instead.

79 ASTRONOMY AND ASTROPHYSICS↗

The Phenix‐AlphaFold webservice: Enabling AlphaFold predictions for use in Phenix

Abstract Advances in machine learning have enabled sufficiently accurate predictions of protein structure to be used in macromolecular structure determination with crystallography and cryo‐electron microscopy data. The Phenix software suite has AlphaFold predictions integrated into an automated pipeline that can start with an amino acid sequence and data, and automatically perform model‐building and refinement to return a protein model fitted into the data. Due to the steep technical requirements of running AlphaFold efficiently, we have implemented a Phenix‐AlphaFold webservice that enables all Phenix users to run AlphaFold predictions remotely from the Phenix GUI starting with the official 1.21 release. This webservice will be improved based on how it is used by the research community and the future research directions for Phenix.

Poon, Billy K.↗

Selecting Appropriate Model Complexity: An Example of Tracer Inversion for Thermal Prediction in Enhanced Geothermal Systems

Abstract A major challenge in the inversion of subsurface parameters is the ill‐posedness issue caused by the inherent subsurface complexities and the generally spatially sparse data. Appropriate simplifications of inversion models are thus necessary to make the inversion process tractable and meanwhile preserve the predictive ability of the inversion results. In this study, we investigate the effect of model complexity on fracture aperture inversion and thermal performance prediction in a field‐scale EGS model. Principal component analysis was used to map the aperture field to a low‐dimensional latent space. The complexity of the inversion model was quantitatively represented by the percentage of total variance in the original aperture fields preserved by the latent space. Tracer, pressure and flow rate data were used to invert for fracture aperture through an ensemble‐based inversion method, and the inferred aperture field was used to predict thermal performance. With an over‐simplified aperture model, ensemble collapse occurred. The inverted aperture models failed to resolve necessary flow and transport features, leading to a biased thermal performance prediction. A complex aperture model involved excessive features and was prone to overinterpreting the inversion data. Both the tracer/pressure/flow rate data reproduction and thermal prediction showed significant uncertainties, making it difficult to properly estimate long‐term thermal performance. Fortunately, our results indicate that there exists an appropriate model complexity which can simultaneously match inversion data and predict thermal performance with an acceptable uncertainty. The quality of the fit of tracer data appears to be a useful indicator of such an appropriate model complexity.

15 GEOTHERMAL ENERGY↗

Temperature-dependent complex dielectric permittivity: a simple measurement strategy for liquid-phase samples

Abstract Microwaves (MWs) are an emerging technology for intensified and electrified chemical manufacturing. MW heating is intimately linked to a material’s dielectric permittivity. These properties are highly dependent on temperature and pressure, but such datasets are not readily available due to the limited accessibility of the current methodologies to process-oriented laboratories. We introduce a simple, benchtop approach for producing these datasets near the 2.45 GHz industrial, medical, and scientific (ISM) frequency for liquid samples. By building upon a previously-demonstrated bireentrant microwave measurement cavity, we introduce larger pressure- and temperature-capable vials to deduce temperature-dependent permittivity quickly and accurately for vapor pressures up to 7 bar. Our methodology is validated using literature data, demonstrating broad applicability for materials with dielectric constant ε' ranging from 1 to 100. We provide new permittivity data for water, organic solvents, and hydrochloric acid solutions. Finally, we provide simple fits to our data for easy use.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Qualitative and quantitative validation of the SINBAD code on complex HPGe gamma-ray spectra

Radionuclides identification and quantification is a serious concern for many applications as safety or security of nuclear power plant or fuel cycle facility, CBRN risk identification, environmental radioprotection and waste measurements. High resolution gamma-ray spectrometry based on HPGe detectors is a performing solution for all these topics. During last decades, a great number of software has been developed to improve gamma spectra analysis. However, some difficulties remain in the analysis when photoelectric peaks are folded together with a high ratio between theirs amplitudes, when the Compton background is much larger compared to the signal of a single peak and when spectra are composed of a great number of peaks. This study deals with the comparison between conventional methods in radionuclides identification and quantification and the code called SINBAD ('Spectrometrie par Inference Non parametrique Bayesienne Deconvolutive'). For many years, SINBAD has been developed by CEA LIST for unfolding complex spectra from HPGe detectors. Contrary to conventional methods using fitting procedures, SINBAD uses a probabilistic approach with Bayesian inference to describe spectrum data. This conventional fitting method founded for example in Genie 2000 is compared with the nonparametric SINBAD approach regarding some key figures of merit as the peak centroid evaluation (identification) and peak surface evaluation (quantification). Unfriendly cases are studied for nuclides detection with closed gamma-rays energies and high photoelectric peak intensity differences. Tests are performed with spectra from the International Atomic Energy Agency (IAEA) for gamma spectra analysis software benchmark and with spectra acquired at the laboratory. Results show that SINBAD and Genie 2000 performances are quite similar with sometimes best results for SINBAD with the important difference that to achieve same performances the nonparametric method is user-friendly compared to the conventional method which need an expert parameters adjustment. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

NETL Electrical Conductivity Relaxation(ECR) Analysis Tool

This application was developed within the solid oxide fuel cell (SOFC) work plan. It calculates the oxygen surface exchange coefficient (k) and oxygen diffusion coefficient (D) for an oxide sample using electrical conductivity relaxation (ECR) data. The tool also produces a heat map showing the associated uncertainty in fitting the ECR data for given pairs of k and D values, so the user can determine the most likely range of k and D values for the tested values. Multiple datasets for the same material can be plotted to decrease uncertainty. The tool can also simulate ECR curves for inputted k and D values and overlay the simulated curves with experimental data for comparison.

electrical conductivity relaxation↗

Subcritical Californium Source Drive Noise Analysis Measurements With Unreflected Uranium (93.15) Hydride

On July 6, 1989, subcritical californium source-driven noise analysis (CSDNA) measurements were performed with bare uranium hydride cylindrical assemblies at the Los Alamos National Laboratory Critical Experiments Facility in KIVA 1. Three configurations of ~7.5 cm radius-enriched (93.15 wt. % 235 U) uranium hydride with a density of ~10 g/cm 3 cylinders were assembled with uranium hydride heights of ~11, ~14, and ~16 cm. The uranium hydride (~2 and ~3 cm high) was in thin-welded stainless steel cans. The neutron multiplication factors obtained on-line from the measured ratios of spectral densities were 0.942 ± 0.002, 0.917 ± 0.003, and 0.867 ± 0.004 for uranium hydride heights of ~16, ~14, and ~11 cm., respectively. Neutron multiplication factors for these three configurations calculated by Los Alamos National Laboratory Monte Carlo methods were 0.952 ± 0.005, 0.922 ± 0.005, and 0.860 ± 0.005, all of which are in good agreement with the measurements. The break frequency noise analysis data could be fitted to obtain the prompt neutron decay constant at all subcritical states. Some data presented in this report are from notes that are not in the logbooks. A discussion of the two different point kinetics theories of the measurements that illustrated the deficiencies of the rigorous theory at low neutron multiplication factors (k eff < 0.80) is given in an Appendix. These measurements may be the only configuration of unreflected, highly enriched uranium hydride configuration assembled. The presence of hydrogen diluted the uranium density, decreasing the reactivity, but this is offset by slowing down the neutron energy to the energy ranges of higher-fission cross sections. Extrapolations to delayed critical indicate that adding one more 3 cm can and one more 2 cm can would result in the unreflected cylindrical system being slightly above critical with a critical mass of ~37 kg, which is considerably less than the critical mass of an unreflected and unmoderated highly enriched uranium metal sphere. An unreflected, highly enriched uranium hydride sphere would have a critical mass less than 37 kg.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A stochastic-dynamic model for global atmospheric mass field statistics

A model that yields the spatial correlation structure of atmospheric mass field forecast errors was developed. The model is governed by the potential vorticity equation forced by random noise. Expansion in spherical harmonics and correlation function was computed analytically using the expansion coefficients. The finite difference equivalent was solved using a fast Poisson solver and the correlation function was computed using stratified sampling of the individual realization of F(omega) and hence of phi(omega). A higher order equation for gamma was derived and solved directly in finite differences by two successive applications of the fast Poisson solver. The methods were compared for accuracy and efficiency and the third method was chosen as clearly superior. The results agree well with the latitude dependence of observed atmospheric correlation data. The value of the parameter c sub o which gives the best fit to the data is close to the value expected from dynamical considerations.

Ghil, M.↗

A kinetic study of the fast micro-pyrolysis of hybrid poplar

Here, hybrid poplar from the clone DN34 was studied to determine the rate of production of bio-oil species with respect to time during the fast pyrolysis process. 300–660 ug samples were pyrolyzed using a micropyrolzer at 500 °C at very high heating rates and very short vapor residence times. Individual poplar samples were run in triplicate at discrete time points ranging from 1 to 20 s in the micropyrolzer. Several bio-oil compounds from each individual sample were analyzed using GC/MS. Select bio-oil compounds, derived from the hemicellulose, cellulose, and lignin fractions of the wood, were used to determine their rates of production from thermal degradation of the biomass. These rates were quantified using standards to determine the weight percent relative to the original raw biomass with respect to time. Pyrolysis kinetic reaction models were fit to this experimental data in order to determine suitability of each model. A first order exponential decay model for degradation of the solid biomass was fit against the data along with a six-step consecutive degradation model previously developed by our group. The experimental data suggests that compounds derived from the hemicellulose are produced at faster rates than that of the lignin or cellulose fractions of the wood, consistent with prior data from thermogravimetric analysis (TGA). When applying the first order exponential decay model, the reaction rates calculated did prove that holocellulose compounds reaction rates were approximately twice that of the lignin compounds reaction rate but did not provide the best fit. The six-step degradation model provided a better fit to all of the biooil compounds and char data, and the stoichiometric parameters derived from the model fit showed that the first three reactions involved mostly the hemicellulose derived compounds while reaction steps 4–6 released cellulose- and lignin-derived compounds.

09 BIOMASS FUELS↗

International Evaluation of Neutron Cross Section Standards

Neutron cross section standards are the basis for the determination of most neutron cross sections. They are used for both measurements and evaluations of neutron cross sections. Not many cross sections can be obtained absolutely - most cross sections are measured relative to the cross section standards and converted using evaluations of the standards. The previous complete evaluation of the neutron cross section standards was finished in 1987 and disseminated as the NEANDC/INDC and ENDF/B-VI standards. R-matrix model fits for the light elements and non-model least-squares fits for all the cross sections in the evaluation were the basis of the combined fits for all of the data. Some important reactions and constants are not standards, but they assist greatly in the determination of the standard cross sections and reduce their uncertainties - these data were also included in the combined fits. The largest experimental database used in the evaluation was prepared by Poenitz and included about 400 sets of experimental data with covariance matrices of uncertainties that account for all cross-energy, cross-reaction and cross-material correlations. For the evaluation GMA, a least-squares code developed by Poenitz, was used to fit all types of cross sections (absolute and shape), their ratios, spectrum-averaged cross sections and thermal constants in one full analysis. But, the uncertainties derived in this manner, and especially those obtained in the R-matrix model fits, have been judged to be too low and unrealistic. These uncertainties were substantially increased prior to their release in the recommended data files of 1987. Modified percentage uncertainties were reassigned by the United States Cross Section Evaluation Working Group's Standards Subcommittee for a wide range of energies, and no covariance (or correlation) matrices were supplied at that time. The need to re-evaluate the cross section standards is based on the appearance of a significant amount of precise experimental data and improved developments in the methodology of analysis and evaluation. Initial efforts to produce a new evaluation were made by the United States Cross Section Evaluation Working Group which formed a Task Force. It was realized that international cooperation would be needed to produce the evaluation. The Working Party on International Evaluation Cooperation of the Nuclear Energy Agency Nuclear Science Committee formed a Subgroup, and the International Atomic Energy Agency formed a Coordinated Research Project (CRP). These groups worked cooperatively to improve the evaluation process. The major effort in producing the evaluation was through the CRP. The evaluations of the neutron cross section standards were finalized in October 2005. Previous difficulties experienced with a data evaluation problem known as 'Peelle's Pertinent Puzzle' create biases in the fit of correlated data, and they have been addressed to reduce this phenomenon. The new evaluations of the cross section standards also include covariance matrices of the uncertainties that contain fully justifiable values. The product of this international effort has been adopted as the neutron standards for ENDF/B-VII.0.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Nonparametric test of consistency between cosmological models and multiband CMB measurements

We present a novel approach to test the consistency of the cosmological models with multiband CMB data using a nonparametric approach. In our analysis we calibrate the REACT (Risk Estimation and Adaptation after Coordinate Transformation) confidence levels associated with distances in function space (confidence distances) based on the Monte Carlo simulations in order to test the consistency of an assumed cosmological model with observation. To show the applicability of our algorithm, we confront Planck 2013 temperature data with concordance model of cosmology considering two different Planck spectra combination. In order to have an accurate quantitative statistical measure to compare between the data and the theoretical expectations, we calibrate REACT confidence distances and perform a bias control using many realizations of the data. Our results in this work using Planck 2013 temperature data put the best fit ΛCDM model at 95% (∼ 2σ) confidence distance from the center of the nonparametric confidence set while repeating the analysis excluding the Planck 217 × 217 GHz spectrum data, the best fit ΛCDM model shifts to 70% (∼ 1σ) confidence distance. The most prominent features in the data deviating from the best fit ΛCDM model seems to be at low multipoles 18 < ℓ < 26 at greater than 2σ, ℓ ∼ 750 at ∼1 to 2σ and ℓ ∼ 1800 at greater than 2σ level. Excluding the 217×217 GHz spectrum the feature at ℓ ∼ 1800 becomes substantially less significance at ∼1 to 2σ confidence level. Results of our analysis based on the new approach we propose in this work are in agreement with other analysis done using alternative methods.

79 ASTRONOMY AND ASTROPHYSICS↗

Radar altimeter waveform modeled parameter recovery

Satellite-borne radar altimeters include waveform sampling gates providing point samples of the transmitted radar pulse after its scattering from the ocean's surface. Averages of the waveform sampler data can be fitted by varying parameters in a model mean return waveform. The theoretical waveform model used is described as well as a general iterative nonlinear least squares procedures used to obtain estimates of parameters characterizing the modeled waveform for SEASAT-1 data. The six waveform parameters recovered by the fitting procedure are: (1) amplitude; (2) time origin, or track point; (3) ocean surface rms roughness; (4) noise baseline; (5) ocean surface skewness; and (6) altitude or off-nadir angle. Additional practical processing considerations are addressed and FORTRAN source listing for subroutines used in the waveform fitting are included. While the description is for the Seasat-1 altimeter waveform data analysis, the work can easily be generalized and extended to other radar altimeter systems.

Source record↗