Search NASA⌕ Search

SEARCH · Search NASA

Results for “Deployable Power Systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,783 records · Page 99

Project Accomplishments Summary - SC12/01790.00. Concentrating Photovoltaics Component and System Research

Sandia National Laboratories (Sandia) and Cool Earth Solar, Inc. (CES) collaborated to evaluate and validate a new Concentrating Photovoltaic (CPV) technology for the utility-scale power market. Project goals included demonstration of CES's tracking and energy production mechanism and operation in a realworld configuration to validate and evaluate mechanical reliability, uptime, operations and maintenance, and energy production models. The test facility was located at Sandia California’s Livermore Valley Open Campus (LVOC). The collaboration allowed CES to quickly move from design concept to system prototype deployment in an operational environment, with approximately 17kW of engineering samples deployed. However, economic pressure from inexpensive flat panel photovoltaic modules caused a major contraction in the broader CPV market. CES was ultimately unable to overcome this economic pressure and discontinued efforts to develop their novel CPV product.

14 SOLAR ENERGY↗

SBIR Phase II Final Report - A Robust Wireless Communication System for Harsh Environments Including Nuclear Facilities

This is the Final Report for the DOE Phase II SBIR project “A Robust Wireless Communication System for Harsh Environments Including Nuclear Facilities.” The topics covered herein include technical progress made, progress against the planned milestones and deliverables, project outcomes, and a discussion on future expectations of deployment and impacts of the results of this work. In brief, all planned work for the project was successfully completed, on or ahead of schedule and on budget. The major accomplishment was the successful development of new sensor/communications systems with wideband (WB)/ultra-wideband (UWB) communications based on the software-defined-radio (SDR) technology to improve sensing and control in nuclear power plants and then a broad range of similar sensing applications. The impacts of these disciplines/focuses of this SBIR include: A new multi-frequency SDR-based architecture with WB/UWB communications integrated with sensors was developed, utilizing 310 MHz, 450 MHz, 915 MHz, and 5 GHz frequencies; Secure communications using Advanced Encryption Standard (AES) algorithm; Sensing possibilities not effectively addressed by previous technologies was addressed; and, The newly developed wireless sensor communications system can adapt its communications parameters to its operational environment for optimal performance. The performance of this system has been evaluated by systematic laboratory and field testing. The field testing was conducted at Massachusetts Institute of Technology (MIT)’s Nuclear Test Reactor, and the McClellan Nuclear center at the University of California Davis (UC Davis), as well as at Oak Ridge National Laboratory (ORNL). The success in this project resulted in DSI being awarded “The DOE’s 2018 SBIR/STTR Small Business of the Year”. This technology has attracted interest from The Rolls Royce company with ongoing discussions under NDA for potential strategic partnership between DSI and Rolls Royce in providing wireless sensor communications in nuclear facilities. Furthermore, the success of this project has attracted significant interest from the United Nations International Atomic Agency (IAEA) in Vienna, Austria, as well as other DOE and DOD offices. Currently, per request from IAEA, DOE’s office of International Safeguards has funded DSI to develop a WB/UWB wireless communication system for real-time transmission of images from IAEA’s safeguards cameras in various nuclear facilities. DSI also has received a Phase II and Phase II.5 SBIR awards from ARMY and NAVY for wireless communications capability for various DOD aircraft.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Coupling of Thermal Energy Storage with Small Modular Reactors

Thermal energy storage has been proposed as a load management strategy for Small Modular Reactors (SMRs) deployed on constrained grids and/or in hybrid energy systems (1). Hybrid energy systems can include process steam applications, and the presence of intermittent energy sources such as wind and solar. Under these conditions, the reactor can be subjected to significant time varying electric loads. One strategy for accommodating these loads is to operate the reactor in a load follow mode where reactor power is modulated to match the electric demand. In addition to lost energy potential, load follow operation can result in additional stresses on the fuel and other mechanical components. A more attractive approach is to operate the reactor at or near steady state and bypass excess steam to a thermal energy storage system. The thermal energy can then be recovered later, either for electric generation during periods of peak electric demand, or for uses in process steam applications. In previous work, the design of a sensible heat Thermal Energy Storage (TES) system was proposed for SMR applications (2). In this paper we examine coupling of the TES system to a SMR, typical of Integral Pressurized Water Reactor (IPWR) designs currently under development. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Commercial EV Charging Infrastructure: Modeling Concepts & Techniques

This presentation offers an overview of key concepts and techniques for modeling global commercial EV charging infrastructure. We begin by comparing the unique needs of commercial vehicles with those of personal vehicles. Next, we delve into network design topics, including phased deployment of public infrastructure, port sharing across and within fleets, power requirements for en-route charging, and strategies for estimating depot charging availability. Finally, we outline the primary steps NREL follows in conducting an EV charging infrastructure needs assessment.

ADVANCED PROPULSION SYSTEMS,DIRECT ENERGY CONVERSI↗

Responsible Adoption of Artificial Intelligence (AI) in Electric Grid Operations

The future of the grid will be powered by AI—or undermined by it. Artificial intelligence is rapidly reshaping grid operations, improving fault detection, forecasting accuracy, and real-time optimization. As AI systems move closer to operational decision loops, however, they introduce new consequence pathways: expanded attack surfaces, model integrity risks, regulatory exposure, and human-automation challenges. This talk presents a consequence-driven framework for deploying AI responsibly in the electric grid. Attendees will gain practical strategies to strengthen resilience, boost reliability, and deploy AI securely — ensuring the grid of the future is not only smarter but safer.

25 - ENERGY STORAGE↗

Adapting Grid Criticality for Data Centers

This presentation explores the evolving definition of “critical load” in the electric grid, emphasizing the growing importance of digital infrastructure—particularly data centers—in grid resilience, restoration, and modernization. As utilities increasingly rely on AI-driven analytics and software-defined control systems, data centers have shifted from passive electricity consumers to essential computational hubs that enable National Critical Functions (NCFs) and support real-time grid operations. The deck examines the scale and impact of digital loads, the need for grid modernization to manage rapid load growth, and the diverse computing paradigms required for AI deployment. It introduces a tiered taxonomy for classifying critical loads, highlights operational dependencies between the grid and digital infrastructure, and discusses policy implications for integrating data centers into emergency planning and restoration protocols. Through case studies and practical frameworks, the presentation provides actionable insights for utilities, regulators, and planners navigating the digital transformation of the power sector.

29 - ENERGY PLANNING, POLICY AND ECONOMY↗

Transient Efficiency Flexibility and Reliability Optimization of Coal-Fired Power Plants: Model-Predictive Control Library Development (Report)

This document pertains to the reporting requirements of DOE contract FE-0031767. The document covers the development of a model predictive control (MPC) library for implementing MPC for a general dynamic system. The library is implemented in a standardized manner in Matlab/Simulink, where core functions on model prediction, linearization and formulation and solution of a quadratic programming (QP) optimization problem is done in the core library - independent of the specific application. The user can provide the application-specific dynamic model in continuous and discrete time, to rapidly implement and test the MPC performance in a desktop simulation. The MPC optimization objective and constraints are also easily configured via an Excel file to allow iterative refinement as needed. Finally, the MPC library enables a rapid deployment to a target environment through auto C-code generation and containerization. The MPC library works seamlessly with the model based estimation (MBE) library to obtain the overall output feedback control solution. In this program, the reduced order model (ROM) of a coal-fired power plant (CFPP) is used to implement and test the MPC solution.

01 COAL, LIGNITE, AND PEAT↗

Heliostat Sizing Methodology for Solar Heat for Industrial Processes

This study presents a method to obtain a heliostat size that minimizes the levelized cost of a heliostat-based concentrating solar thermal system for industrial process heat (IPH) applications at operating temperatures from 565 to 1550 degrees Celsius. The method extends prior work by embedding a routine for system design that obtains near-optimal subsystem sizes, increasing the fidelity of drive cost functions, and adding an optical performance model. An illustrative business case is developed for Daggett, California, targeting specified annual thermal energy outputs of 50 to 400 GWhth. Optical performance is modeled using verified estimates from the literature. A surrogate heliostat cost model, derived from commercial heliostat designs and scaled for production volume, installation, and operations and maintenance costs, is used to develop cost functions. Results show that heliostat size strongly affects the levelized cost of heat (LCOH), producing a characteristic U-shaped trend with a robust near-optimal window of 8 - 12 m2; the heliostat size producing the lowest project cost in our study grows slightly as the project size increases, and is reduced as the operating temperature increases. The findings in this study are consistent with the general trend of smaller heliostats under deployment at existing projects for high-temperature industrial process heat and reflect the significant reduction in power electronics and other per-heliostat costs. The methodology we propose is general and can be tailored to revised cost curves as the technology continues to evolve.

14 SOLAR ENERGY↗

Low-Altitude Unmanned Aerial Vehicles as a Tool for the Remediation of Radiologically Contaminated Environments - 16257

Following the events at the Fukushima Daiichi Nuclear Power Plant (FDNPP) in March 2011, significant quantities of radioactive material were released into the local Japanese as well as the wider global environment. At the fifth anniversary of the incident, much work and expense is still being dedicated to the remediation of a large area of eastern Japan, contaminated primarily with radio-caesium. Due to the complex topography of the geographical area of Japan effected, it is important to understand contaminant evolution/migration at the greatest possible resolution - previous methods have lacked this. An increase in the spatial resolution of radiation mapping over other previous methods has been achieved through the deployment of an unmanned aerial vehicle (UAV). The platform used during this work combined a low-altitude multi-rotor UAV with a lightweight radiation mapping system to achieve sub-meter resolution. Using this system it was possible to measure the distribution of radionuclide contamination at a number of sites within the Fukushima Prefecture region of Japan. Unlike ground-based surveys conducted on foot by humans that attain a comparable resolution, such a system eliminates the potentially significant dose that would otherwise be received, as well as the influence of shielding on results. In addition to providing a rapid and high resolution response to radiological incidents, such monitoring technology has the potential to be a powerful tool in post-operational clean-out (POCO) at nuclear sites undergoing decommissioning worldwide. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Vulcan Test Platform: Demonstrating the Data Center as a Flexible Grid Asset

Explosive data center demand is outpacing grid infrastructure development. AI workloads and hyperscale cloud growth are creating unprecedented power requirements, while traditional grid expansion faces multi-year development timelines, regulatory hurdles, and decarbonization challenges. Sidewalk Infrastructure Partners recognized this impending crisis years ago and founded Verrus to develop an innovative solution: data centers that function as grid assets rather than passive loads. The Verrus approach integrates proprietary grid-aware controls with battery energy storage systems (BESS) in a medium-voltage architecture that delivers three critical capabilities: Fast-responding demand flexibility that can service requests from the utility within 10 seconds, Uninterrupted transition to islanded operation during grid disturbances, Continuous uptime assurance while maintaining all customer service level commitments Through Verrus' strategic partnership with the National Renewable Energy Laboratory (NREL), we validated these capabilities on Vulcan, a 70 MW utility-scale test platform powered by NREL's ARIES Virtual Emulation Environment. This deployment-ready technology has successfully demonstrated that Verrus data centers can deliver meaningful grid services while maintaining mission-critical reliability. This technical report outlines the design, methodology, and results of this emulated deployment, demonstrating that data centers can play a pivotal role in enhancing grid flexibility and reliability, without sacrificing service level guarantees.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Quantifying agricultural productive use of energy load in Sub-Saharan Africa and its impact on microgrid configurations and costs

The use of advanced energy technologies for agricultural purposes—such as irrigation, refrigeration, crop processing, and egg incubation—has the potential to increase crop yield, reduce vulnerability to changing precipitation patterns, increase shelf life, strengthen income and employment opportunities in rural areas, and reduce emissions by displacing fossil fuel-based technologies. These productive uses of energy (PUE) in remote areas could potentially be powered by microgrids that additionally serve otherwise unelectrified communities, most of which are located in rural Sub-Saharan Africa. Here, in this paper, we use high-resolution geospatial data to estimate the end-use electricity demand for a range of agricultural PUE across Sub-Saharan Africa, and we share these data in an open-access mapping tool. Next, we use REopt®, a techno-economic optimization model of energy systems, to determine the cost and system sizing implications of incorporating agricultural PUE into microgrid designs in Kenya and Zambia. We estimate the upper bound of agricultural PUE demand for irrigation, milling, shelling, refrigeration, and egg incubation across Sub-Saharan to be 16.8 TWh/yr. We find that incorporating local agricultural PUE into microgrid system designs increases the required system sizing while having minimal impact on the levelized cost of energy of these systems. Our analysis is the first to demonstrate the PUE potential in the agricultural sector at a 10x10-kilometer resolution across Sub-Saharan Africa and to show, at scale, how site-specific PUE can impact the cost and sizing of microgrids that are otherwise deployed to serve local household and community load.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Pre-commercial Demonstration of Direct Non-iterative State Estimator for Operational Use of Synchrophasor Management Systems

The objective of this project was to demonstrate functionality and performance of a Direct Non-iterative State Estimator (DNSE) integrated with NYPA’s Energy Management System (EMS) and with enhanced Real Time Dynamics Monitoring System (RTDMS) synchrophasor platform from Electric Power Group (EPG). DNSE is designed to overcome a major obstacle to operational use of Synchro-Phasor Management Systems (SPMS) by providing to synchrophasor management systems (SPMS) applications a consistent and a complete synchrophasor data foundation in the same way that a traditional EMS State Estimator (SE) provides to EMS applications. Specifically, DNSE is designed to use synchrophasor measurements collected by a central PDC, Supervisory Control and Data Acquisition (SCADA) measurements, and Energy Management System (EMS) network model, to obtain the complete state of the utility’s operating model at rates that are close to the synchrophasor data rates. In this way, the system is comprehensive in that it does not only cover the part of the network that is “visible” via synchrophasors, but also the part that is only “visible” through the SCADA measurements. Visualization needs associated with the use of DNSE results are fulfilled through suitably enhanced Real Time Dynamics Monitoring System (RTDMS), with the enhancements implemented by EPG. This project had the following goals in mind: To advance the deployment of commercial grade DNSE software application that relies on synchrophasor and SCADA data ; Apply DNSE at other utilities, to address a generic and fundamental need for “clean” operational data for synchrophasor applications; Provide means for “live” estimated data access by control system operators; Enhance potential for situational awareness through full system operational model coverage; Sub-second execution rate of the Direct Non-iterative State Estimator, eventually at a near-phasor data rate execution speed, i.e. < 0.1 sec. Anticipated benefits from this projects are: Enhanced reliability and improvements in the economic efficiency of bulk power system planning and operations; Providing “clean” data to other synchrophasor applications; Enhancement of situational awareness by providing the full operational model updated at near synchrophasor rate; A production-grade software tool that incorporate synchrophasor and SCADA data; Provides a basis for development of next generation monitoring and control applications, based on both SCADA and PMU data. Quanta Technology (QT) team worked in collaboration with Electric Power Group (EPG) whose team has enhanced its commercial Real Time Dynamics Monitoring System (RTDMS) to accommodate the requirements posed by DNSE application. EPG also provided its ePDC and Model-less Data Conditioning (PDVC) software for integration with DNSE+. QT developed the system requirements for DNSE; developed system architecture and defined interfaces between internal DNSE components. The core DNSE algorithm with all surrounding interfaces was named DNSE+. Since the DNSE development was done in a simulated system environment, QT used its PMU simulator that was enhanced during this project for development and factory acceptance testing (FAT). SCADA data in this stage was simulated by commercial PSS/e software. The output of DNSE are estimates of System states in C37.118-2 format, sent to RTDMS for further processing and display. As the number of these states is large, it was necessary to expand the C37.111-2 standard to accommodate large data sets. This enhancement was implemented in RTDMS. The demonstration of pre-production DNSE technology was done at NYPA using streaming field data from NYPA PMUs and from its RTUs through their SCADA system. NYPA provided ICCP interface as well as Common Information Model (CIM). The relevance of the DNSE+ application is that it provides state estimation of the power system based on hybrid set of data, consisting of both available PMU data and SCADA measurements. As this is a direct, non-iterative method of calculation of the system states, if does not suffer from convergence issues which is potential problem for conventional state estimators. Also, it can take any available PMU measurements, so it does not need to have a high percentage of PMU coverage needed in the case of Linear State Estimator. As the DNSE calculates synchrophasors of the system states (both phase and absolute value) as sub-second rate, this application can provide a basis for development of next generation of applications based both on SCADA and PMU data.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Dynamic Braking System of a Tidal Generator

Renewable energy generation has experienced significant cost reductions during the past decades, and it has become more accepted by the global population. In the beginning, wind generation dominated the development and deployment of renewable energy; however, during recent decades, photovoltaic (PV) generation has grown at a very significant pace due to the tremendous decrease in the cost of PV modules. The focus on renewable energy generation has now expanded to include new types with promising future applications, such as river and tidal generation. The input water flow to these types of resources is more predictable than wind or solar generation. The data used in this paper is representative of a typical river or tidal generator. The analysis is based on a generator with a power rating of 40 kW. The tidal generator under consideration is driven by two sets of helical turbines connected to each side of the generator located in between the turbines. The generator is operated in variable speed, and it is controlled to maximize the energy harvested as well as the operation of the turbine generator. The electrical system consists of a three-phase permanent magnet generator connected to a three-phase passive rectifier. The output of the rectifier is connected to a DC-DC converter to match the rectifier output to the DC bus voltage of the DC-AC inverter. The three-phase inverter is connected to the grid, and it is controlled to provide a good interface with the grid. One important aspect of river and tidal generation is the braking mechanism. In a tidal generator, the braking mechanism is important to avoid a runaway condition in case the connection to the grid is lost when there is a fault in the lines. A runaway condition may lead to an overspeed condition and cause extreme stresses on the turbine blade structure and eventual disintegration of the mechanical structure. In this paper, the concept of the dynamic braking system is developed and investigated for normal and abnormal operations. The main objective is to optimize the performance under emergency braking while designing the system to be as simple as possible to avoid overdesigning the power electronics or exceeding the target budget.

13 HYDRO ENERGY↗

On SCALE Validation for PBR Analysis

Studies were performed to assess the capabilities of the SCALE code system to provide accurate cross sections for analyses of pebble bed reactor configurations. The analyzed configurations are representative of fuel in the HTR-10 reactor in the first critical core and at full power operation conditions. Relevant parameters-multiplication constant, spectral indices, few-group cross sections-are calculated with SCALE for the considered configurations. The results are compared to results obtained with corresponding consistent MCNP models. The code-to-code comparison shows good agreement at both room and operating temperatures, indicating a good performance of SCALE for analysis of doubly heterogeneous fuel configurations. The development of advanced methods and computational tools for the analysis of pebble bed reactor (PBR) configurations has been a research area of renewed interest for the international community during recent decades. The PBR, which is a High Temperature Gas Cooled Reactor (HTGR) system, represents one of the potential candidates for future deployment throughout the world of reactor systems that would meet the increased requirements of efficiency, safety, and proliferation resistance and would support other applications such as hydrogen production or nuclear waste recycling. In the U.S, the pebble bed design is one of the two designs under consideration by the Next Generation Nuclear Plant (NGNP) Program.

08 HYDROGEN↗

Development of a Real-Time, High-Speed Distribution Level Data Acquisition System

With the development of smart grids and the deployment of their enabling technologies, improved data acquisition will be needed at the distribution level to understand the full impact of these changes. With this in mind, NREL has developed a high-speed measurement and data collection network targeted specifically at the distribution level. This network is based around adaptable, rugged measurement devices designed for deployment at a variety of low and medium voltage locations below the sub-station. Each of these devices is capable of real-time data transmission via an Internet connection. Additionally, several analysis and visualization applications have been developed around the incoming data streams.

14 SOLAR ENERGY↗

Demonstration of reconstruction-free static magnetic control of DIII-D plasma with deep reinforcement learning

This paper presents the development and experimental validation of a reinforcement learning (RL)-based magnetic controller on the DIII-D tokamak. The controller directly maps raw magnetic diagnostic signals to actuator commands, replacing the traditional isoflux control algorithm based on equilibrium reconstruction. Four RL controllers are trained using the Soft Actor–Critic algorithm with an asymmetric Actor–Critic architecture in the NSFsim simulator. All controllers are deployed in the DIII-D Plasma Control System and operated with a 4 kHz feedback loop. Two randomization strategies are evaluated during training: evolving kinetic profiles and fixed kinetic profiles within each episode. The latter approach is found to better capture experimental deviations in the current density profile and to provide overall improved control performance. Robust operation is demonstrated across heating power scans in both L- and H-mode plasmas, as well as during transient events such as L–H transitions and pellet injections. Control errors in plasma shape and radial position remained within 1.5–2.0 cm and 1 cm, respectively. A notable discrepancy was observed in the vertical X-point position, with errors of up to approximately 4 cm, attributed to the current density distribution mismatches between simulations and experiments.

DIII-D↗

Faster-than-real-time Simulation with Demonstration for Resilient DER Integration

The US electric grid is facing operational, stability, and security challenges. Transmission system operators need some measure of visibility into distribution system renewable generation. Distribution system generation needs to support transmission system voltage. The grid is experiencing an expansion in measurement systems. How to take full advantage of this expansion and defend against attacks, both cyber and physical, poses additional challenges. The Faster-than-real-time Simulation with demonstration for Resilient DER Integration project set out to do the following: a. Flatten the voltage profile through the feeders and system for cost saving and voltage stabilization needs. b. Increase the amount of intermittent distributed energy resources (IDERs) that could be deployed on a utility feeder and provide 100% or more energy needed for the demands on that feeder, and c. based on an accurate model (Digital Twin) of the utilities system, be able to detect any abnormalities on the utilities distribution system. To manage the voltage and increase IDER penetration (a,b), Graph Trace Analysis is employed in a time-series, optimal power flow to coordinate the time-varying feedback control setpoints of a distribution feeder’s utility control devices. Under the coordinated control are a Load Tap Changing Transformer, a voltage regulator, and five switched capacitor banks. The feeder serves over 2000 customers, the feeder secondaries are modeled, and the feeder has 2.3 MW of PV generation, corresponding to a 17.4% penetration of PV generation. The feeder model has over 12,000 components, where every customer load bus and PV generator are modeled. The accuracy of the power flow solution is compared against historical meter voltage measurements, the improvement in conservation voltage reduction energy savings as a function of the coordinated control desired voltage profile is investigated, and the increase in PV penetration of the coordinated control over the existing control is presented. To achieve improved control performance while observing system operation constraints, bellwether Advanced Metering Infrastructure (AMI) voltage measurements are used to adjust the desired voltage profile used by the optimal power flow analysis. To detect and alleviate or negate attacks or failures on the distribution and transmission utility grids (c) the grid needs to be resilient and self-healing. In this project software was designed to do just that. At the center of the software is an Integrated System Model (ISM) that spans from transmission to secondary distribution. The ISM is employed in real-time abnormality detection, voltage stability forecasting, and multi-mode control. Testing results are presented for: 1—attacks on utility infrastructure; 2—energy savings from optimal control; 3—distribution system control response during a low voltage transmission system event; 4—cyber-attacks on PV inverters, where physical inverters are used in hard-ware-in-the-simulation-loop studies. Contributions of this work include real-time analysis that spans from three-phase transmission through secondary distribution; an approach for detecting abnormalities that employs measurements from three independent measurement systems; and a multi-mode distribution system control that responds to cyber-attacks, physical attacks, equipment failures, and transmission system needs.

Integrated System Model, Graph Trace Analysis, Adv↗

Volttron: An Agent Platform for the Smart Grid

VOLLTRON platform enables the deployment of intelligent sensors and controllers in the smart grid and provides a stable, secure and flexible framework that expands the sensing and control capabilities. VOLTTRON platform provides services fulfilling the essential requirements of resource management and security for agent operation in the power grid. The facilities provided by the platform allow agent developers to focus on the implementation of their agent system and not on the necessary "plumbing' code. For example, a simple collaborative demand response application was written in less than 200 lines of Python.

agents↗