Search NASA⌕ Search

SEARCH · Search NASA

Results for “EVALUATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,783 records · Page 99

Conical ultrashort echo time (UTE) MRI in the evaluation of pediatric acute appendicitis

Purpose: Magnetic resonance imaging (MRI) sequences with conical k-space trajectories are able to decrease motion artifacts while achieving ultrashort echo times (UTE). We assessed the performance of free-breathing conical UTE MRI in the evaluation of the pediatric pelvis for suspected appendicitis. Methods: Our retrospective review of 84 pediatric patients who underwent MRI for suspected appendicitis compared three contrast-enhanced sequences: free-breathing conical UTE, breath-hold three-dimensional (3D) spoiled gradient echo (BH-SPGR), and free-breathing high-resolution 3D SPGR (FB-SPGR). Two radiologists performed blinded and independent evaluations of each sequence for image quality (four point scale), anatomic delineation (four point scale), and diagnostic confidence (five point scale). Subsequently, the three sequences were directly compared for overall image quality (− 3 to + 3 scale). Scores were compared using Kruskal–Wallis and Wilcoxon signed-rank tests. Results: UTE demonstrated significantly better perceived signal-to-noise ratio (SNR) and fewer artifacts than BH-SPGR and FB-SPGR (means of 3.6 and 3.4, 3.4 and 3.2, 3.1 and 2.7, respectively; p < 0.0006). BH-SPGR and FB-SPGR demonstrated significantly better contrast than UTE (means of 3.6, 3.4, and 3.2, respectively; p < 0.03). In the remaining categories, UTE performed significantly better than FB-SPGR (p < 0.00001), while there was no statistical difference between UTE and BH-SPGR. Direct paired comparisons of overall image quality demonstrated the readers significantly preferred UTE over both BH-SPGR (mean + 0.5, p < 0.00001) and FB-SPGR (mean + 1.2, p < 0.00001). Conclusions: In the evaluation of suspected appendicitis, free-breathing conical UTE MRI performed better in the assessed metrics than FB-SPGR. When compared to BH-SPGR, UTE demonstrated superior perceived SNR and fewer artifacts.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A prospective feasibility study evaluating the role of multimodality imaging and liquid biopsy for response assessment in locally advanced rectal carcinoma

Purpose: Colorectal cancer is a commonly encountered disease that poses several diagnostic and therapeutic challenges. The inherent heterogeneity of tumor biology and propensity to relapse despite “curative” resection pose significant challenges with regard to response assessment. Although MR imaging already plays a key role in primary staging of patients with rectal carcinoma, its reliability in restaging after neoadjuvant therapy is debatable (Van der broek et al. in Dis Colon Rectum 60(3):274–283, 2017). Therefore, there is significant interest in developing additional methods which may improve diagnostic accuracy. This study aims to evaluate the role of multimodality imaging and liquid biopsy in therapeutic response assessment. Methods: Seventeen patients were enrolled into the study over a span of 24 months. All underwent hybrid PET-MRI and CT-perfusion (CT-P), prior to and following neoadjuvant therapy for locally advanced rectal carcinoma. Twelve of the 17 patients also underwent liquid biopsy, which consisted of blood sampling and analysis of circulating tumor cells (CTCs) and extracellular vesicles (EVs), including cell fragments and microparticles (MPs), using the Cell Search System (Menarini Silicon Biosystems). SUV, DWI, and ADC were calculated during PET-MRI, and several parameters were evaluated during CT-perfusion, including average perfusion, blood flow (BF), blood volume (BV), mean transit time (MTT), permeability-surface area product (PS), contrast extraction efficiency (E), and K-trans (K). Changes observed pre- and post-neoadjuvant therapy in each modality were compared to tumor response at histopathology using a modified Ryan tumor regression grading system. Results: Of the 17 patients included in the study, 14 were classified as non-responders, and 3 were classified as responders as determined by the modified Ryan Tumor Regression Grade (TRG) scoring system (Van der broek et al. in Dis Colon Rectum 60(3):274–283, 2017). When combined, blood markers and CT-P parameters (mean transit time (MTT), K-trans, and permeability-surface area product (PS)) produced the strongest models (p < 0.01). PET (SUV measurement) combined with CT-P-derived K-trans produced a marginally significant (p = 0.057) model for predicting response. MRI-derived ADC value did not provide a significant model for response prediction. Conclusion: A model of CT-P parameters plus liquid biopsy more accurately predicts tumor response than PET-MRI, CT-P alone, or liquid biopsy alone. These results suggest that in the evaluation of treatment response, liquid biopsy could provide additional information to functional imaging modalities such as CT-P and should therefore be explored further in a trial with larger sample size.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Chemosaturation Percutaneous Hepatic Perfusion (CS-PHP) with Melphalan: Evaluation of 2D-Perfusion Angiography (2D-PA) for Leakage Detection of the Venous Double-Balloon Catheter

Purpose: To evaluate the feasibility of 2D-perfusion angiography (2D-PA) for detecting leakage of the double-balloon catheter used for chemosaturation percutaneous hepatic perfusion (CS-PHP). Materials and Methods: Overall, 112 CS-PHP (09/2015-09/2018) in 52 patients were retrospectively screened for leakage alongside the double-balloon catheter on standard venograms. Finally, 18 procedures with visually detected leakage were included. Fifteen consecutive procedures without leakage served as control. To evaluate 2D-PA for leakage detection, the acquired digital subtraction venograms were post-processed. For each balloon, two different target ROIs were evaluated to assess a possible impact of localization and shape of the ROIs. Time to peak (TTP), peak density (PD), area under the curve (AUC), and ratios of target ROI/reference ROIs (PD{sub tROI}/PD{sub REF}; AUC{sub tROI}/AUC{sub REF}; and TTP{sub tROI}/TTP{sub REF}) were calculated. Results: Leakages were located as follows: 15/18 cranial and 3/18 caudal. At the cranial balloon both ROIs showed a significant decrease in PD{sub tROI}/PD{sub REF} and AUC{sub tROI}/AUC{sub REF} (ROI1: p < 0.0001; p < 0.0001; ROI2: p < 0.0001; p < 0.0001) and a significant increase in TTP{sub tROI}/TTP{sub REF} (ROI1: p = 0.0009; ROI2: p = 0.0003) after double-balloon correction. Following balloon adjustment, the 2D-PA ratios (PD and AUC) of the tested ROIs differed significantly (p < 0.05). The inter-individual comparison of the 2D-PA parameters of the group with leakage before balloon correction and the non-leakage group showed significantly different 2D-PA values for the cranial balloon in both ROIs (p < 0.05). No significant differences were found for the caudal balloon. Conclusion: 2D-PA provides a feasible tool for detecting leakages alongside the cranial portion of the double-balloon catheter used in CS-PHP. The shape and position of the ROIs used to assess perfusion and flow have an impact on the measurements.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comprehensive Evaluation of Fast-Response, Reynolds-Averaged Navier–Stokes, and Large-Eddy Simulation Methods Against High-Spatial-Resolution Wind-Tunnel Data in Step-Down Street Canyons

Three computational fluid dynamics (CFD) methods with different levels of flow-physics modelling are comprehensively evaluated against high-spatial-resolution wind-tunnel velocity data from step-down street canyons (i.e., a short building downwind of a tall building). The first method is a semi-empirical fast-response approach using the Quick Urban Industrial Complex (QUIC-URB) model. The second method solves the Reynolds-averaged Navier–Stokes (RANS) equations, and the third one utilizes a fully-coupled fluid-structure interaction large-eddy simulation (LES) model with a grid-turbulence inflow generator. Unlike typical point-by-point evaluation comparisons, here the entire two-dimensional wind-tunnel dataset is used to evaluate the dynamics of dominant flow topological features in the street canyon. Each CFD method is scrutinized for several geometric configurations by varying the downwind-to-upwind building-height ratio (H d /H u ) and street canyon-width to building-width aspect ratio (S / W) for inflow winds perpendicular to the upwind building front face. Disparities between the numerical results and experimental data are quantified in terms of their ability to capture flow topological features for different geometric configurations. Ultimately, all three methods qualitatively predict the primary flow topological features, including a saddle point and a primary vortex. But, the secondary flow topological features, namely an in-canyon separation point and secondary vortices, are only well represented by the LES method despite its failure for taller downwind building cases. Misrepresentation of flow-regime transitions, exaggeration of the coherence of recirculation zones and wake fields, and overestimation of downwards vertical velocity into the canyon are the main defects in QUIC-URB, RANS and LES results, respectively. All three methods underestimate the updrafts and, surprisingly, QUIC-URB outperforms RANS for the streamwise velocity component, while RANS is superior to QUIC-URB for the vertical velocity component in the street canyon.

58 GEOSCIENCES↗

Evaluating opportunities to improve material and energy impacts in commodity supply chains

When evaluated at the scale of individual processes, next-generation technologies may be more energy and emissions intensive than current technology. Furthermore, many advanced technologies have the potential to reduce material and energy consumption in upstream or downstream processing stages. In order to fully understand the benefits and consequences of technology deployment, next-generation technologies should be evaluated in context, as part of a supply chain. This work presents the Materials Flow through Industry (MFI) supply chain modeling tool. The MFI tool is a cradle-to-gate linear network model of the US industrial sector that can model a wide range of manufacturing scenarios, including changes in production technology and increases in industrial energy efficiency. The MFI tool was developed to perform supply chain scale analyses in order to quantify the impacts and benefits of next-generation technologies and materials at that scale. For the analysis presented in this paper, the MFI tool is utilized to explore a case study comparing three lightweight vehicle supply chains to the supply chain of a conventional, standard weight vehicle. Several of the lightweight vehicle supply chains are evaluated under manufacturing scenarios that include next-generation production technologies and next-generation materials. Results indicate that producing lightweight vehicles is more energy and emission intensive than producing the non-lightweight vehicle, but the fuel saved during vehicle use offsets this increase. In this case study, greater reductions in supply chain energy and emissions were achieved through the application of the next-generation technologies than from application of energy efficiency increases.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Nonlinear Impact-Echo Test for Quantitative Evaluation of ASR Damage in Concrete

Nonlinear acoustic methods demonstrate high sensitivity for concrete damage evaluation. Among these methods, nonlinear resonance acoustic methods have been widely used in laboratory tests on small scale test samples. In this study, a nonlinear impact-echo (IE) method for concrete damage evaluation was introduced, in which the IE frequency shift was measured at different impact force levels. The nonlinear IE test and the nonlinear impact resonance acoustic spectroscopy (NIRAS) test share similarities in the experimental setup and analysis method. However, the nonlinear IE test excites a local thickness resonance mode of a member instead of the global resonance vibration. Therefore, the analyzed mode is unaffected by member boundary conditions and is applicable to large concrete structural members. To identify the fundamental IE frequencies, multiple impacts were applied along the members. Once the fundamental IE frequencies were determined, the effectiveness of the nonlinear IE method was evaluated by testing seven concrete beam specimens with varying levels of alkali-silica reaction (ASR) damage. In conclusion, the nonlinear IE test demonstrates high sensitivity to concrete damage and allows for quantitative assessment of the damage state of concrete without a baseline measurement.

36 MATERIALS SCIENCE↗

Evaluation of Plastic “Eta” Factor for Welds of SS316L(N) with High Strength Mismatch Ratio

Fracture testing standards of ASTM and ISO recommend expressions for plastic η factor of various fracture test specimen geometries to evaluate the fracture behavior of materials. These are intended for homogenous specimens, but according to ISO 15653, it can be extended for weldments up to a strength mismatch ratio (M) of 1.25. In practice, M > 1.25 is encountered in many applications. In the present study, η factor has been evaluated for welded compact tension specimens using a limit load-based approach. The η factors obtained using this approach for homogenous specimens with elastic–perfectly plastic material model are found to be within ± 4% of those from the ASTM E 1820-17a, thereby validating the procedure. For welds, the limit load is obtained from nonlinear (elastic–plastic) FE simulations. η factors for specimens with various crack lengths (a), weld width (h) and strength mismatch have been evaluated and found to be significantly influenced by these parameters. For M > 1.25, the estimated η values were found to be ~ 16% lower compared to that from the ASTM E 1820-17a. Thus, the use of the η values from the proposed method provides a conservative estimate of J–R curve for the welds. Further, it has been observed that depending on the slope of the blunting line, the J{sub Ic} value may vary significantly with the estimated η values.

36 MATERIALS SCIENCE↗

Using an Artificial Neural Network for Nondestructive Evaluation of the Heat Treating Processes for D2 Tool Steels

In nondestructive evaluation (NDE) of heat-treated steels, different variables of the heat treating process have complex effects on outputs of NDE methods, and hence, the effect of one desired variable on NDE outputs should be evaluated to help interpreting the changes. In the present paper, the potential of the magnetic hysteresis method was evaluated for simultaneous detection of the austenitizing and tempering temperatures of AISI D2 samples parts subjected to different heat treatment conditions. To produce the microstructural changes, five groups of the samples were austenitized at 1025-1130 °C, quenched in oil and finally each group was tempered in the range 200-650 °C. SEM and x-ray diffractometry techniques were used to characterize different produced microstructures. For accurate and simultaneous prediction of tempering and austenitizing temperatures, an artificial neural network (ANN) was implemented for magnetic hysteresis outputs including magnetic saturation, coercivity and maximum differential permeability. The study revealed that the magnetic NDE system coupled to ANN has the ability to be adopted as an effective expert NDE tool to predict heat treatment effects on D2 tool steels.

36 MATERIALS SCIENCE↗

Evaluation and calibration of MERRA-2 and CAMS reanalysis for PM 2.5 in a semi-urbanized area in the south of the Amazon

Air pollution has significant implications for the climate and poses irreversible risks to human health. The Amazon region of Brazil is severely affected by biomass burning (BB) emissions, yet air quality monitoring remains highly inadequate. Given the scarcity of surface-based observations, reanalysis models have become essential tools for assessing air pollution. Although MERRA-2 and CAMS PM 2.5 products are widely utilized, their validation and comprehensive evaluation for the Amazon Basin remain limited. Here, this study assesses the performance of these products in a semi-urbanized region in the southern Amazon. The calibrated time series was employed to analyze PM 2.5 concentrations from 2003 to 2023. Our results showed satisfactory performance of both products for the 24-h averages of PM 2.5 , with linear correlations above 0.76. However, it was found that both products overestimate surface concentrations. MERRA-2 performed better, with approximately 30% lower bias than CAMS. Time series analysis showed that the study area is strongly impacted by emissions BB in the dry period, mainly in August and September. Furthermore, our findings indicate a positive trend in increasing PM 2.5 concentrations, with a notable rise observed since 2014. The average PM 2.5 levels frequently exceed the daily air quality guidelines established by the WHO in 2021. It has been estimated that the population of this region is exposed to concentrations above 15 μg.m -3 , on average, more than 30 days per year. Our results contribute to the evaluation of MERRA-2 and CAMS products for Amazon and provide a corrected estimate for surface PM 2.5 . Recent concerns about air quality and the implementation of new surface monitoring networks may improve the evaluation of reanalysis products. In the short term, the need for this information makes our assessments indispensable.

54 ENVIRONMENTAL SCIENCES↗

Use of Cardiac Imaging to Evaluate Cardiac Function and Pulmonary Hemodynamics in Patients with Heart Failure

Purpose of Review: Noninvasive hemodynamic assessments in patients with heart failure (HF) are essential for appropriate diagnosis and establishment of the best treatment strategies. Recently, the impact of pulmonary circulation and right ventricular function on prognosis in HF patients has drawn increasing attention. In this article, we explore the usefulness of cardiac imaging for hemodynamic assessments, mainly focusing on echocardiographic evaluation. Recent Findings: The reliability of Doppler echocardiography as a noninvasive alternative to Swan-Ganz catheterization has been well investigated with higher than 80% accuracy for estimating pulmonary artery pressure. Strain measurement and three-dimensional echocardiography are useful for evaluating right ventricular function together with pulmonary circulation. The accuracy of analyzing left and right ventricular functions by cardiac computed tomography and cardiac magnetic resonate imaging has also been established. These modalities can provide myocardial tissue information and allow calculation of the extracellular volume fraction as well. Summary: According to the rapid improvement of technologies, cardiac imaging has become an essential tool for hemodynamic evaluation in HF management.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

An Evaluation of “Drug Ineffective” Postmarketing Reports in Drug Safety Surveillance

Introduction: The most commonly reported adverse event, based on frequency of Medical Dictionary for Regulatory Activities (MedDRA) preferred terms (PTs), in the US FDA Adverse Event Reporting System (FAERS) database is ‘‘drug ineffective’’ (DI). This study aimed to describe the DI reports and provide data to support recommendations on how to best evaluate these reports. Methods: We characterized all FAERS reports coded with the MedDRA PT ‘‘drug ineffective’’ received between 1 September 2012 and 31 August 2016 using all other FAERS reports as a comparator. Additionally, we conducted a manual evaluation to identify informative data elements in the report narratives. Results: During the study period, 247,513 (6.4% of all FAERS reports) DI reports were entered in FAERS. Compared with non-DI reports, DI reports were more likely to be reported by consumers (69.8 vs. 48.1%) and less likely to report a serious outcome (26.2 vs. 56.3%). Most DI reports (88%) were from the USA. Manual evaluation of 552 sample US reports identified 43 reports (7.8%) deemed ‘‘useful’’; a higher proportion of ‘‘useful’’ reports provided a batch or lot number (39.5 vs. 17.2%) and were coded with additional PTs beyond ‘‘drug ineffective’’ (83.7 vs. 59.2%), the most frequent of which were ‘‘product quality issue’’ (23.3%) and ‘‘product substitution issue’’ (18.6%). Conclusions: DI was the most frequently reported adverse event in the FAERS database; however, the yield from these reports in terms of usefulness from a pharmacovigilance perspective was low. Efficient strategies are needed to identify which DI reports are more likely to contain useful information.

60 APPLIED LIFE SCIENCES↗

Non-contact electrochemical evaluation of biofilms

Abstract Here, we demonstrate a non-contact technique for electrochemical evaluation of biofilms on surfaces in relation to corrosion. Electrochemical impedance spectrometry was employed, incorporating flat patterned electrodes positioned over the surfaces of aluminum and glass with and without biofilms. Signal communication from the working electrode to the counter electrode followed electric field lines passing tangentially through the biofilms. Electrochemical impedance parameters that were evaluated included complex impedance, phase angle, imaginary (out of phase) conductivity and Cole–Cole plots with a corresponding equivalent circuit. Changes in the impedance properties due to the presence of biofilms were monitored and correlated through microbiological, chemical and electrochemical assays. Impedance parameters associated with microbial activity correlated with biofilms on aluminum and glass surfaces. This technical approach provides impedance information about the biofilm without the signal traveling through the underlying conductive media or disrupting the biofilm. In this way, biological contributions to surface fouling can be evaluated with minimal contribution from the inorganic surface under the biofilm. In addition, this technique can be used to monitor biofilms on electrochemically inert surfaces as well as electrically conductive surfaces. Graphic abstract

Turick, Charles E. (ORCID:0000000307815846)↗

Quantitative resilience evaluation on recovery from emergency situations in nuclear power plants

Here, this paper mainly introduces how to develop a resilience evaluation model by quantifying the relationship between resilience and resilience components in regard to recovering from emergency situations in nuclear power plants (NPPs). It is an extension of the author’s previous researches. To develop the model, the first step was to analyze event reports published in Republic of Korea in terms of resilience factors from different safety perspectives. Second, statistical methods such as factor analysis, principal component analysis, and multivariate regression analysis were applied to the dataset to identify relations among resilience factors and develop a quantitative resilience evaluation model for recovery from emergency situations in NPPs. Third, the model was validated using the recent event report data released in Korea. Lastly, we present a discussion on how to apply the quantitative resilience evaluation model to results from stress tests performed in Korea.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Energy efficiency evaluation of a stationary lithium-ion battery container storage system via electro-thermal modeling and detailed component analysis

Energy efficiency is a key performance indicator for battery storage systems. A detailed electro-thermal model of a stationary lithium-ion battery system is developed and an evaluation of its energy efficiency is conducted. The model offers a holistic approach to calculating conversion losses and auxiliary power consumption. Sub-models for battery rack, power electronics, thermal management as well as the control and monitoring components are developed and coupled to a comprehensive model. The simulation is parametrized based on a prototype 192 kWh system using lithium iron phosphate batteries connected to the low voltage grid. The key loss mechanisms are identified, thoroughly analyzed and modeled. Generic profiles featuring various system operation modes are evaluated to show the characteristics of stationary battery systems. Typically the losses in the power electronics outweigh the losses in the battery at low power operating points. The auxiliary power consumption dominates for low system utilization rates. For estimation of real-world performance, the grid applications Primary Control Reserve, Secondary Control Reserve and the storage of surplus photovoltaic power are evaluated. Conversion round-trip efficiency is in the range of 70-80%. Finally, overall system efficiency, which also considers system power consumption, is 8-13 percentage points lower for Primary Control Reserve and the photovoltaic-battery application. However, for Secondary Control Reserve, the total round-trip efficiency is found to be extremely low at 23% due to the low energy throughput of this application type.

25 ENERGY STORAGE↗

A method to evaluate hydraulic fracture using proppant detection

Accurate determination of the proppant placement and propped fracture height are important for evaluating and optimizing stimulation strategies. A technology using non-radioactive proppant and a pulsed neutron gamma energy spectra logging tool to determine the placement and height of propped fractures is proposed in this paper. Gd 2 O 3 was incorporated into ceramic proppant and a Monte Carlo method was utilized to build the logging tools and formation models. Characteristic responses of the recorded information of different logging tools to fracture widths, proppant concentrations and influencing factors were studied. The results show that Gd capture gamma rays can be used to evaluate propped fractures and it has higher sensitivity to the change of fracture width and traceable proppant content compared with the exiting non-radioactive proppant evaluation techniques and only an after-fracture measurement is needed for the new method; The changes in gas saturation and borehole size have a great impact on determining propped fractures when compensated neutron and pulsed neutron capture tool are used. Finally, a field example is presented to validate the application of the new technique.

47 OTHER INSTRUMENTATION↗

SKLPT imaging: Efficient in vivo pre-evaluation of genome-editing modules using fluorescent protein with peroxisome targeting signal

Numerous studies have used genome-editing modules such as CRISPR-Cas9 for site-directed mutagenesis; however, evaluation of the efficiency of these modules remains a time-consuming process. Here, we report the development of SKL-mediated Peroxisome Targeting Imaging (SKLPT imaging), an efficient in vivo pre-evaluation method based on the change in subcellular localization of a fluorescent protein. In this method, frameshifts resulting from successful editing cause the fusion of green fluorescent protein to the peroxisome localization signal Serine-Lysine-Leucine (SKL). Using SKLPT imaging, we pre-evaluated three CRISPR-Cas9 modules in vivo at the single-cell level, and then efficiently mutagenized the liverwort (Marchantia polymorpha) genome using a high-efficiency module.

60 APPLIED LIFE SCIENCES↗

Performance evaluation of an agent-based occupancy simulation model

Occupancy is an important factor driving building performance. Static and homogeneous occupant schedules, commonly used in building performance simulation, contribute to issues such as performance gaps between simulated and measured energy use in buildings. Stochastic occupancy models have been recently developed and applied to better represent spatial and temporal diversity of occupants in buildings. However, there is very limited evaluation of the usability and accuracy of these models. This study used measured occupancy data from a real office building to evaluate the performance of an agent-based occupancy simulation model: the Occupancy Simulator. The occupancy patterns of various occupant types were first derived from the measured occupant schedule data using statistical analysis. Then the performance of the simulation model was evaluated and verified based on (1) whether the distribution of observed occupancy behavior patterns follows the theoretical ones included in the Occupancy Simulator, and (2) whether the simulator can reproduce a variety of occupancy patterns accurately. Results demonstrated the feasibility of applying the Occupancy Simulator to simulate a range of occupancy presence and movement behaviors for regular types of occupants in office buildings, and to generate stochastic occupant schedules at the room and individual occupant levels for building performance simulation. For future work, model validation is recommended, which includes collecting and using detailed interval occupancy data of all spaces in an office building to validate the simulated occupant schedules from the Occupancy Simulator.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Laboratory testing methods to evaluate the reliability of occupancy sensors for commercial building applications

The energy performance of commercial buildings is greatly influenced by occupants which are highly variable and among the most unpredictable components of a building's operation. While most building control systems use fixed, predetermined occupancy schedules, these fixed occupancy levels can be quite different from actual occupancy. This can cause unnecessary energy consumption, particularly from heating, ventilation, and air conditioning (HVAC) and lighting systems which are responsible for approximately 60% of commercial buildings' energy use. The use of occupancy counting sensor systems integrated with building management system controls is one method that can be used to improve the energy-consuming performance of buildings. However, there is no standardized universal methodology and metrics to evaluate their reliability. The aim of this research is to develop a uniform evaluation methodology to assess the reliability of occupancy counting sensor systems in a controlled laboratory environment. The developed testing methodology includes both “typical” scenarios representing the occupancy scenarios of a typical commercial building, and “failure” testing scenarios which represent a range of potential scenarios that may impact a sensor system's reliability. These methods were then implemented in a case study to evaluate the performance of two novel occupancy counting sensor systems (i.e., door-centric, and camera-based). Results suggest that typical testing results can be used to compare the overall performance of the occupancy counting sensor systems; however, failure testing is also important to understand the weaknesses of the sensor system in order to select the suitable one for the intended use of the commercial building. In addition, the proposed methodology includes a modified confusion matrix which enables the ability to identify if failures are caused by over or under counting occupants and to what extent this occurs over the testing period.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗