Search NASA⌕ Search

SEARCH · Search NASA

Results for “Image processing.”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,783 records · Page 99

Impact damage in filament wound composite bottles

Increasingly, composite materials are being used in advanced structural applications because of the significant weight savings they offer when compared to more traditional engineering materials. The higher cost of composites must be offset by the increased performance that results from reduced structural weight if these new materials are to be used effectively. At present, there is considerable interest in fabricating solid rocket motor cases out of composite materials, and capitalizing on the reduced structural weight to increase rocket performance. However, one of the difficulties that arises when composite materials are used is that composites can develop significant amounts of internal damage during low velocity impacts. Such low velocity impacts may be encountered in routine handling of a structural component like a rocket motor case. The ability to assess the reduction in structural integrity of composite motor cases that experience accidental impacts is essential if composite rocket motor cases are to be certified for manned flight. While experimental studies of the post-impact performance of filament wound composite motor cases haven been proven performed (2,3), scaling impact data from small specimens to full scale structures has proven difficult. If such a scaling methodology is to be achieved, an increased understanding of the damage processes which influence residual strength is required. The study described herein was part of an ongoing investigation of damage development and reduction of tensile strength in filament wound composites subjected to low velocity impacts. The present study, which focused on documenting the damage that develops in filament wound composites as a result of such impacts, included two distinct tasks. The first task was to experimentally assess impact damage in small, filament wound pressure bottles using x-ray radiography. The second task was to study the feasibility of using digital image processing techniques to assist in determining the 3-D distribution of damage from stereo x-ray pairs.

Highsmith, Alton L.↗

A Method of Ground-Based Cloud Motion Predict: CCLSTM + SR-Net

Ground-based cloud images can provide information on weather and cloud conditions, which play an important role in cloud cover monitoring and photovoltaic power generation forecasting. However, the cloud motion prediction of ground-based cloud images still lacks advanced and complete methods, and traditional technologies based on image processing and motion vector calculation are difficult to predict cloud morphological changes. In this paper, we propose a cloud motion prediction method based on Cascade Causal Long Short-Term Memory (CCLSTM) and Super-Resolution Network (SR-Net). Firstly, CCLSTM is used to estimate the shape and speed of cloud motion. Secondly, the Super-Resolution Network is built based on perceptual losses to reconstruct the result of CCLSTM and, finally, make it clearer. We tested our method on Atmospheric Radiation Measurement (ARM) Climate Research Facility TSI (total sky imager) images. The experiments showed that the method is able to predict the sky cloud changes in the next few steps.

54 ENVIRONMENTAL SCIENCES↗

RhizoVision Explorer: open-source software for root image analysis and measurement standardization

Abstract Roots are central to the function of natural and agricultural ecosystems by driving plant acquisition of soil resources and influencing the carbon cycle. Root characteristics like length, diameter and volume are critical to measure to understand plant and soil functions. RhizoVision Explorer is an open-source software designed to enable researchers interested in roots by providing an easy-to-use interface, fast image processing and reliable measurements. The default broken roots mode is intended for roots sampled from pots and soil cores, washed and typically scanned on a flatbed scanner, and provides measurements like length, diameter and volume. The optional whole root mode for complete root systems or root crowns provides additional measurements such as angles, root depth and convex hull. Both modes support providing measurements grouped by defined diameter ranges, the inclusion of multiple regions of interest and batch analysis. RhizoVision Explorer was successfully validated against ground truth data using a new copper wire image set. In comparison, the current reference software, the commercial WinRhizo™, drastically underestimated volume when wires of different diameters were in the same image. Additionally, measurements were compared with WinRhizo™ and IJ_Rhizo using a simulated root image set, showing general agreement in software measurements, except for root volume. Finally, scanned root image sets acquired in different labs for the crop, herbaceous and tree species were used to compare results from RhizoVision Explorer with WinRhizo™. The two software showed general agreement, except that WinRhizo™ substantially underestimated root volume relative to RhizoVision Explorer. In the current context of rapidly growing interest in root science, RhizoVision Explorer intends to become a reference software, improve the overall accuracy and replicability of root trait measurements and provide a foundation for collaborative improvement and reliable access to all.

59 BASIC BIOLOGICAL SCIENCES↗

Variation in forest root image annotation by experts, novices, and AI

Abstract Background The manual study of root dynamics using images requires huge investments of time and resources and is prone to previously poorly quantified annotator bias. Artificial intelligence (AI) image-processing tools have been successful in overcoming limitations of manual annotation in homogeneous soils, but their efficiency and accuracy is yet to be widely tested on less homogenous, non-agricultural soil profiles, e.g., that of forests, from which data on root dynamics are key to understanding the carbon cycle. Here, we quantify variance in root length measured by human annotators with varying experience levels. We evaluate the application of a convolutional neural network (CNN) model, trained on a software accessible to researchers without a machine learning background, on a heterogeneous minirhizotron image dataset taken in a multispecies, mature, deciduous temperate forest. Results Less experienced annotators consistently identified more root length than experienced annotators. Root length annotation also varied between experienced annotators. The CNN root length results were neither precise nor accurate, taking ~ 10% of the time but significantly overestimating root length compared to expert manual annotation ( p = 0.01). The CNN net root length change results were closer to manual ( p = 0.08) but there remained substantial variation. Conclusions Manual root length annotation is contingent on the individual annotator. The only accessible CNN model cannot yet produce root data of sufficient accuracy and precision for ecological applications when applied to a complex, heterogeneous forest image dataset. A continuing evaluation and development of accessible CNNs for natural ecosystems is required.

Handy, Grace↗

Nonlinear optical thin films

A focused approach to development and evaluation of organic polymer films for use in optoelectronics is presented. The issues and challenges that are addressed include: (1) material synthesis, purification, and the tailoring of the material properties; (2) deposition of uniform thin films by a variety of methods; (3) characterization of material physical properties (thermal, electrical, optical, and electro-optical); and (4) device fabrication and testing. Photonic materials, devices, and systems were identified as critical technology areas by the Department of Commerce and the Department of Defense. This approach offers strong integration of basic material issues through engineering applications by the development of materials that can be exploited as the active unit in a variety of polymeric thin film devices. Improved materials were developed with unprecedented purity and stability. The absorptive properties can be tailored and controlled to provide significant improvement in propagation losses and nonlinear performance. Furthermore, the materials were incorporated into polymers that are highly compatible with fabrication and patterning processes for integrated optical devices and circuits. By simultaneously addressing the issues of materials development and characterization, keeping device design and fabrication in mind, many obstacles were overcome for implementation of these polymeric materials and devices into systems. We intend to considerably improve the upper use temperature, poling stability, and compatibility with silicon based devices. The principal device application that was targeted is a linear electro-optic modulation etalon. Organic polymers need to be properly designed and coupled with existing integrated circuit technology to create new photonic devices for optical communication, image processing, other laser applications such as harmonic generation, and eventually optical computing. The progression from microscopic sample to a suitable film-forming material in a working device is a complex, multifaceted endeavor. It requires close attention to maintaining the optical properties of the electro-optic active portion of the polymer while manipulating the polymer structure to obtain the desired secondary polymer properties.

Leslie, Thomas M.↗

Graphics Processing Unit Assisted Thermographic Compositing

Objective Develop a software application utilizing high performance computing techniques, including general purpose graphics processing units (GPGPUs), for the analysis and visualization of large thermographic data sets. Over the past several years, an increasing effort among scientists and engineers to utilize graphics processing units (GPUs) in a more general purpose fashion is allowing for previously unobtainable levels of computation by individual workstations. As data sets grow, the methods to work them grow at an equal, and often greater, pace. Certain common computations can take advantage of the massively parallel and optimized hardware constructs of the GPU which yield significant increases in performance. These common computations have high degrees of data parallelism, that is, they are the same computation applied to a large set of data where the result does not depend on other data elements. Image processing is one area were GPUs are being used to greatly increase the performance of certain analysis and visualization techniques.

Ragasa, Scott↗

Recent advances in remote sensing; Proceedings of the First International Geoscience and Remote Sensing Symposium, Washington, DC, June 8-10, 1981

The state of the art in remote sensing of the earth and the planets was discussed in terms of sensor performance, signal processing, and data interpretation. Particular attention was given to lidar for characterizing atmospheric particulates, the modulation of short waves by long ocean gravity waves, and runoff modeling for snow-covered areas. The use of NOAA-6 spacecraft AVHRR data to explore hydrologic land surface features, the effects of soil moisture and vegetation canopies on microwave and thermal microwave emissions, and regional scale evapotranspiration rate determination through satellite IR data are examined. A Shuttle experiment to demonstrate high accuracy global time and frequency transfer is described, along with features of the proposed Gravsat, radar image processing for rock-type discrimination, and passive microwave sensing of temperature and salinity in coastal zones.

Mcintosh, R.↗

Physicochemical evolution of uranium nitride kernel microstructure with varying carbon distribution for advanced TRISO fuel forms

Uranium nitride (UN) has emerged as a fuel candidate for advanced nuclear reactor concepts due to its superior uranium density, thermal conductivity, and high melting temperature. However, the fabrication route for converting UO 2 to UN is complex and difficult to standardize. Although the chemistry of this conversion process is well-studied, more insight into the physicochemical dynamics of this conversion using advanced characterization techniques can help further our understanding of this material system. This work leveraged thermogravimetric analysis (TGA), X-ray diffraction (XRD), and nondestructive 3D X-ray computed tomography (XCT) to characterize dynamic microstructural changes in the UO 2 → UCO → UN fabrication pathway for two kernels with a varying carbon distribution in the starting composition. TGA and XRD were used to quantify changes in the mass, density, and chemical composition of the two kernels, while three-dimensional image processing and segmentation of XCT data were used to quantify the volume, surface area, and spatial distribution of features within each kernel for multiple steps along the fabrication pathway. The analysis indicates distinct differences between the two kernels that are correlated to downstream conversion efficiency. In conclusion, this work is among the first to perform 3D quantification of physicochemical evolution during UN conversion, providing quantitative correlation between processing, properties, and expected fuel performance.

Nuclear fuel↗

Optimum exposure conditions for computed radiography depending on fixed pattern noise and efficiency of imaging plate-scanner systems

The presently active standards on Computed Radiography (CR) need a major revision. It was observed by many users that the image quality for class B of EN 14784-2 is not achievable under the same exposure conditions as used for film exposure. A mathematical model was developed and tested, which allows the calculation of the image quality, proven by image quality indicators (IQI), depending on the fixed pattern noise and the efficiency of the used imaging plate (IP) scanner system. All tested IP scanner systems provide a fixed correlation between the measured signal/noise ratio (SNR) and the grey values in the digital images. The maximum achievable SNR{sub max} depends on the fixed pattern noise of the plate (high dose limit). Depending on the exposure dose an optimum visibility of IQIs can be predicted by calculation and measured considering the attenuation coefficient for calculation of the contrast/noise ratio (CNR). The diameter of the just visible wire is proportional to 1/sqrt(CNR). The optimum tube voltage for best visibility of IQIs and maximum CNR depend on the exposure dose. The optimum tube voltage for best visibility is achieved only at exposures with high dose. A dose dependant optimal tube voltage was not observed for film radiography.

07 ISOTOPE AND RADIATION SOURCES↗

Phantom study to evaluate contrast-medium-enhanced digital subtraction mammography with a full-field indirect-detection system

This phantom study simulates contrast-medium-enhanced digital subtraction mammography (CEDM) and compares subtracted image quality and total mean glandular dose for two alternative spectral combinations available in a GE Senographe DS mammography unit. The first choice takes advantage of large iodine attenuation at low photon energies and uses traditionally available spectra (anode/filter combinations Mo/Mo at 25 kV and Rh/Rh at 40 kV, ''Mo25-Rh40''). The second choice, selected from a previous analytical optimization, includes harder spectra obtained by adding external filtration to traditional beams (Rh/Rh at 34 kV and Rh/Rh+5 mm of Al at 45 kV, ''Rh34-Rh45H''). Individual images of a custom-made phantom containing tubes of various diameters filled with water- or iodine-based contrast agent were acquired with both spectral combinations. The total breast entrance air kerma, considering subtraction of two images, was limited to 8.76 mGy (1 R). The results were compared to predictions obtained through an analytical formalism that assumes noise of stochastic origin. Individual images were evaluated and subtracted under five combinations of temporal and dual-energy modalities. Signal variance analysis in individual raw images showed important contributions of nonstochastic origin, associated with the software applied to raw images, the curved geometry, and strong attenuation of the phantom cylindrical iodine-filled tubes, causing experimental SNR to vary from 2.2 to 0.8 times the predictions from low to high values of SNR. Iodine contrast in the subtracted images was found to be mainly defined by the spectra, independent of exposure, and linearly dependent on the iodine mass thickness. The highest contrast was obtained with the combined dual-energy temporal subtraction with Rh34-Rh45H, its value was 7% larger than the highest value measured with Mo25-Rh40. As expected, temporal modalities (single and dual energy, any spectral choice) led to higher contrast-over-noise ratio (CNR) than nontemporal dual-energy subtraction, the latter being negligibly small with Mo25-Rh40. CNR for 4 mg iodine/cm{sup 2} imaged temporally in a dual-energy fashion with Rh34-Rh45H (iodine imaged at high energy) is about 1.7 times the optimum for Mo25-Rh40 (iodine imaged at low energy). Iodine thicknesses needed to fulfill Rose's criterion were 0.78{+-}0.02 mg iodine/cm{sup 2} for Mo25-Rh40 and 0.54{+-}0.17 mg iodine/cm{sup 2} for Rh34-Rh45H, both lower than the proposed biological concentration of iodine in breast tumors after contrast medium administration. Although similar dose levels were obtained with both spectral choices under dual-energy (temporal and nontemporal) subtraction, the dose obtained in single-energy temporal subtraction with the Mo25 spectrum was 1.2 mGy lower than the dose from the modality offering the highest CNR. In all results considered, the spectral choice Mo25-Rh40 was found to represent an interesting alternative to the use of high-energy hardened spectra for CEDM, particularly when performing dynamic studies of the contrast-agent uptake in breast lesions.

61 RADIATION PROTECTION AND DOSIMETRY↗

Summer Student Internship working on the GPU

This summer internship consisted of learning computer programming skills and languages including Thrust, CUDA, C++, C and Linux. The application of this programming is for use in GPU, graphics processing units, that are processors that perform math intensive calculations rapidly in three dimensions typically in advanced video games (“NVIDIA GeForce…”). Our goal is to apply this technology towards exa-scale computing on the LANL supercomputing infrastructure. My mentors use these machines to do computations. The completed algorithms include KD tree and Top K. In order to access the GPU, CUDA was used. CUDA is a parallel computer architecture for general computing on the GPUs. There are different means by which to access CUDA. The first approach uses libraries, like Thrust, Linear Algebra, and Signal and Image Processing. Another approach parallelizes loops in Fortran or C and in the last approach people develop custom parallel algorithms using familiar language (“What is CUDA”). The algorithms I worked on this summer use the first approach of using the thrust library of parallel algorithms and data structures.

97 MATHEMATICS AND COMPUTING↗

Advances and challenges in CO2 foam technologies for enhanced oil recovery in carbonate reservoirs

Utilization of surfactants for generating foam has the potential for fluid-mobility control during CO2 flooding processes, leading to improved oil recovery. This manuscript is a review of the most important aspects for the design of CO2-foams with mobility control in carbonate reservoirs, including recent advances in novel surfactants and analytical techniques for analysis of surfactant adsorption on carbonate minerals and their thermal stability. Several key parameters and properties regarding foam transport in porous media are reviewed such as, the minimum pressure gradient required for foam generation, the effects of the partition coefficient of a CO2-soluble surfactant on foam transport in rock cores, visualization of foam flow by either microfluidic or PET/CT imaging processes in heterogeneous or fractured systems and the effect of oil on foam transport under reservoir conditions. Also are discussed the most recent advances of two major foam modeling methods, including the semi-empirical STARS foam model and the population balance model, as well as CO2 foam pilot tests and the factors governing their successes.

Jian, Guoqing↗

Comparative Assessment of U-Net-Based Deep Learning Models for Segmenting Microfractures and Pore Spaces in Digital Rocks

Segmentation of high-resolution X-ray microcomputed tomography (µCT) images is crucial in digital rock physics (DRP), affecting the characterization and analysis of microscale phenomena in the porous media. The complexity of geological structures and nonideal scanning conditions pose significant challenges to conventional image segmentation approaches. Motivated by the recent increasing popularity of deep learning (DL) techniques in image processing, this work undertakes a comparative study of DL models, specifically U-Net and its variants, for segmenting multiple targets with distinguished features in digital rocks, including discrete fracture networks (DFNs), pore spaces, and solid rock. Particularly, DFNs have a smaller volumetric fraction over others, bringing in a substantial challenge of imbalanced segmentation. The primary focus is to evaluate the architecture and feature enhancement strategies of various DL models, including U-Net, attention U-Net, residual U-Net, U-Net++, and residual U-Net++. The models were designed as 2.5D, utilizing a central 2D image and its two adjacent upper and lower 2D images as input to provide a pseudo-3D context. In addition, because the ground truth of segmentation was unknown for real-world digital rocks, we created a benchmark data set following the inverse operations of segmentation. The data synthesis started from the label images (i.e., solid rock, pore spaces, and DFNs), followed by simulating partial volume blurring, adding random background noise, and introducing ring artifacts to mimic real raw X-ray µCT images. The data set, which included various rock types (i.e., sandstone and artificial data), scanning resolution, and magnitudes of noise and artifacts, was divided into training and testing data sets with a 90% and 10% ratio, respectively. Moreover, in addition to the conventional pixel-wise evaluation metrics, the physics-based metric of the lattice-Boltzmann method (LBM) simulated permeability provided more comprehensive assessments. The results demonstrated that the residual connections, nested architectures, and redesigned skip connections contribute to the model performance and give the residual U-Net++ the highest accuracy. The improvements were mainly on the boundaries and small targets, especially the DFNs, which dominate the interconnectivity and therefore affect the permeability greatly. This study also rigorously evaluated the efficiency and generalization of each model, demonstrating that the sophisticated architectures achieved excellent practicability and maintained robust performance on completely unseen data, ensuring their suitability for diverse and challenging DRP applications.

58 GEOSCIENCES↗

Image-Based Methods to Score Fungal Pathogen Symptom Progression and Severity in Excised Arabidopsis Leaves

Image-based symptom scoring of plant diseases is a powerful tool for associating disease resistance with plant genotypes. Advancements in technology have enabled new imaging and image processing strategies for statistical analysis of time-course experiments. There are several tools available for analyzing symptoms on leaves and fruits of crop plants, but only a few are available for the model plant Arabidopsis thaliana (Arabidopsis). Arabidopsis and the model fungus Botrytis cinerea (Botrytis) comprise a potent model pathosystem for the identification of signaling pathways conferring immunity against this broad host-range necrotrophic fungus. Here, we present two strategies to assess severity and symptom progression of Botrytis infection over time in Arabidopsis leaves. Thus, a pixel classification strategy using color hue values from red-green-blue (RGB) images and a random forest algorithm was used to establish necrotic, chlorotic, and healthy leaf areas. Secondly, using chlorophyll fluorescence (ChlFl) imaging, the maximum quantum yield of photosystem II (Fv/Fm) was determined to define diseased areas and their proportion per total leaf area. Both RGB and ChlFl imaging strategies were employed to track disease progression over time. This has provided a robust and sensitive method for detecting sensitive or resistant genetic backgrounds. A full methodological workflow, from plant culture to data analysis, is described.

59 BASIC BIOLOGICAL SCIENCES↗

Automation Technologies Impact on the Work Process of Nuclear Power Plants

The current cost associated with the work process of nuclear power plants necessities modernizing the work process by augmenting it with automation technologies. This work was performed to assess various automation technologies and the means by which they assimilate into the work process in order to make gains in cost savings in modern nuclear power plants. The goal was to identify key informational items that would be useful to members of industry who are undertaking the large effort to reduce costs through automation by identifying technology maturity levels, recent research, and an analysis of cost impacts of the work process. The technologies cost saving was categorized into low, medium, and high cost savings. Through this effort, a substantive literature review and analysis of recent technological and market trends was performed. The key areas of cost impact were identified through communication with users in industry from operations and maintenance organizations. The results were assembled into a list of work process steps and technologies that are ready be implemented or researched for the automating aspects of that step. This effort aims to present to utilities opportunities of cost saving that are achievable in the short term, and gaps for research organizations and vendors to consider for further research and development. The results of this effort generated a list of technologies that fit each of the three cost saving categories. Electronic work packages remain a high cost saving technology, but data mining and integration, smart scheduling, and dynamic risk models are also indicated to yield a high cost savings. Video applications, spatial mapping, and image processing and identification technologies appear to provide solid cost savings in the medium category, and rounding out the low cost saving areas are deployable technologies such as bar codes, communication tools, and electronic tags.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Image Quality and Radiation Dose Assessment of a Digital Mammography System

Image quality and radiation dose of a direct amorphous selenium digital mammography system were considered in terms of contrast to noise ratio (CNR) and average glandular dose (AGD). They were measured for various qualities and breast phantom thicknesses with different types of breast tissue composition to determine optimal radiation quality and dose. Three sets of breast tissue equivalent slabs (30%:70%, 50%:50% and 70%:30% glandular-adipose) with thickness of 2 cm to 7 cm and 0.2 mm aluminum foil were used to provide certain CNR. Two different combinations of anode/ilter material and a wide range of tube voltages were employed for each phantom thickness. Phantom images with grid were acquired using automatic exposure control (AEC) mode for each thickness. Phantom images without grid were also obtained in manual exposure mode by selecting the same anode/filter combination and kVp as the image obtained with grid at the same thickness, but varying mAs of 10 to 200 mAs. Optimization indicated that relatively high energy beam qualities should be used with a greater dose to compensate for lower energy x-rays. The results also indicate that current AEC setting for a fixed detector is not optimal.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of Two Methods of Noise Power Spectrum Determinations of Medical Radiography Systems

Noise in medical images is recognized as an important factor that determines the image quality. Image noise is characterized by noise power spectrum (NPS). We compared two methods of NPS determination namely the methods of Wagner and Dobbins on Lanex Regular TMG screen-film system and Hologic Lorad Selenia full field digital mammography system, with the aim of choosing the better method to use. The methods differ in terms of various parametric choices and algorithm implementations. These parameters include the low pass filtering, low frequency filtering, windowing, smoothing, aperture correction, overlapping of region of interest (ROI), length of fast Fourier transform, ROI size, method of ROI normalization, and slice selection of the NPS. Overall, the two methods agreed to the practical value of noise power spectrum between 10{sup -3}-10{sup -6} mm{sup 2} over spatial frequency range 0-10 mm{sup -1}.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Neutron Induced Beta Radiography

In the present paper we give a new methodology named, 'neutron induced beta radiography-NIBR' which makes use of neutron activated Dy or In foils as source of (3-radiation. Radiographs are obtained with an aluminium cassette containing image plate, a sample under inspection and the activated Dy or In foil kept in tight contact. The sensitivity of the technique to thickness was evaluated for different materials in the form of step wedges. Some radiographs are presented to demonstrate potential of method to inspect thin samples.

07 ISOTOPE AND RADIATION SOURCES↗