Search NASA⌕ Search

SEARCH · Search NASA

Results for “LOADING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,783 records · Page 99

Electric Load Planning Tool (ELPT) v0.9

The Electric Load Planning Tool (ELPT) helps facilities understand the economic and environmental impacts of their electricity consumption. Using a user-provided Excel input, ELPT analyzes electricity use, costs, and grid CO2e emissions to identify savings opportunities through load management strategies such as load shifting, shedding, and planning. It accounts for Time-of-Use (TOU) tariffs and hourly emissions factors, varying by location and time of day. Users input details about their facility's load profile, location, year of analysis, and electricity billing tariff to receive customized insights. The tool provides visual representations of cost and GHG impacts, helping users understand the benefits of adjusting electricity usage to align with periods of cheaper and cleaner electricity, thereby achieving cost savings and reducing Scope 2 CO2e emissions

Karki, Unique [Lawrence Berkeley National Laborato↗

Analysis of the role of PCNA-DNA contacts during clamp loading

Background: Sliding clamps, such as Proliferating Cell Nuclear Antigen (PCNA) in eukaryotes, are ring-shaped protein complexes that encircle DNA and enable highly processive DNA replication by serving as docking sites for DNA polymerases. In an ATP-dependent reaction, clamp loader complexes, such as the Replication Factor-C (RFC) complex in eukaryotes, open the clamp and load it around primer-template DNA. Results: We built a model of RFC bound to PCNA and DNA based on existing crystal structures of clamp loaders. This model suggests that DNA would enter the clamp at an angle during clamp loading, thereby interacting with positively charged residues in the center of PCNA. We show that simultaneous mutation of Lys 20, Lys 77, Arg 80, and Arg 149, which interact with DNA in the RFC-PCNA-DNA model, compromises the ability of yeast PCNA to stimulate the DNA-dependent ATPase activity of RFC when the DNA is long enough to extend through the clamp. Fluorescence anisotropy binding experiments show that the inability of the mutant clamp proteins to stimulate RFC ATPase activity is likely caused by reduction in the affinity of the RFC-PCNA complex for DNA. We obtained several crystal forms of yeast PCNA-DNA complexes, measuring X-ray diffraction data to 3.0 Å resolution for one such complex. The resulting electron density maps show that DNA is bound in a tilted orientation relative to PCNA, but makes different contacts than those implicated in clamp loading. Because of apparent partial disorder in the DNA, we restricted refinement of the DNA to a rigid body model. This result contrasts with previous analysis of a bacterial clamp bound to DNA, where the DNA was well resolved. Conclusion: Mutational analysis of PCNA suggests that positively charged residues in the center of the clamp create a binding surface that makes contact with DNA. Disruption of this positive surface, which had not previously been implicated in clamp loading function, reduces RFC ATPase activity in the presence of DNA, most likely by reducing the affinity of RFC and PCNA for DNA. The interaction of DNA is not, however, restricted to one orientation, as indicated by analysis of the PCNA-DNA co-crystals.

59 BASIC BIOLOGICAL SCIENCES↗

Performing k eff Validation of As-Loaded Criticality Safety Calculations Using UNF-ST&DARDS: Applicable Experiment Selection

The general method for performing validation of as loaded criticality safety calculations using UNF ST&DARDS is presented in a paper by Clarity, which includes a description of the UNF-ST&DARDS system. Proof-of-principle analyses were performed in the summer of 2019 for MPC-32 dual purpose canisters (DPCs) containing pressurized water reactor (PWR) fuel assemblies. Summaries of these results are presented in this and a companion paper for this conference. The current paper describes the TSUNAMI-IP calculations performed to select applicable experiments for validation of 11 MPC-32 DPCs. The companion paper discusses the TSUNAMI-3D calculations used to generate sensitivity data to support the experiment selections discussed here. Experiment selection is based on the sensitivity/uncertainty (S/U) methods used to validate criticality safety calculations of as-loaded DPCs containing pressurized water reactor (PWR) spent nuclear fuel (SNF). This process has been demonstrated and is summarized in this paper. The approach is similar to that used in NUREG/CR-7109, which provides an approach for validation of PWR burnup credit (BUC), including major and minor actinides and major fission products. The premise of S/U-based validation is that applicable experiments—those having a similar bias to a given application system—will have similar sensitivities for each isotope and reaction in the two systems. It is assumed that cross sections with larger uncertainties are more likely to contain data errors which contribute to the bias. The integral index c k thus propagates the system sensitivities with the nuclear covariance data to calculate a correlation coefficient representing the similarity of the two systems. In this work, a c k value of 0.8 or higher is interpreted as identifying an experiment with sufficient similarity for use in validation. This paper presents a brief summary of the characteristics of the 11 MPC-32 DPCs used in the proof of-principle analysis for as-loaded criticality safety calculation validation and an overview of the critical experiment suite with which each of these DPC models was compared. A summary and discussion of c k results is also presented, followed by conclusions and a discussion of future work to be performed for validation of UNF ST&DARDS as-loaded criticality safety calculations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Bismuth-Loaded Polymer Scintillators for Gamma Ray Spectroscopy

We synthesize a series of polyvinylcarbazole monoliths containing varying loadings of triphenyl bismuth as a high-Z dopant and varying fluors, either organic or organometallic, in order to study their use as scintillators capable of gamma ray spectroscopy. A trend of increasing bismuth loading resulting in a better-resolved photopeak is observed. For PVK parts with no fluor or a standard organic fluor, diphenylanthracene, increasing bismuth loading results in decreasing light yield while with samples 1 or 3 % by weight of the spin-orbit coupling organometallic fluor FIrpic, which emits light from both singlet and triple excitons, show increasing light yield with increasing bismuth loading. Our best performing PVK/ BiPh{sub 3}/FIrpic scintillator with 40 wt % BiPh3 and 3 wt % FIrpic has an emission maximum of 500 nm, a light yield of {approx}30,000 photons/MeV, and energy resolution better than 7% FWHM at 662 keV. Replacing the Ir complex with an equal weight of diphenylanthracene produces a sample with a light yield of {approx}6,000 photons/MeV, with an emission maximum at 420 nm and energy resolution of 9% at 662 keV. Transmission electron microscopy studies show that the BiPh{sub 3} forms small clusters of approximately 5 nm diameter.

36 MATERIALS SCIENCE↗

Mobilizing the anti-duck brigade: technology and market pathways for load-shifting demand response in California

With rapidly increasing renewable power generation, the California electricity system is experiencing the impacts of the so-called “duck curve,” with occasional over-generation in the middle of the day, followed by rapid ramping of net demand producing a sharp evening peak. Mitigating this pattern will require novel demand-side management approaches to shifting demand away from high net demand periods and toward high renewables generation periods. In this paper, drawing from more than 200,000 individual residential, commercial, and industrial customers’ hourly smart meter data, we disaggregate load shapes for certain key end-uses and then average the results across a highly granular set of customer segments by sector, building type, demand profile and geographic region, to yield a library of characteristic daily load profiles (“clusters”) for different end-uses and seasons. By categorizing the library into particularly desirable or undesirable load shapes in the context of mitigating the duck curve, we can gain insight into specific technologies, seasonal effects, or site-level attributes that may serve as helpful levers to use in developing future load-shifting programs. Based on these insights, we develop recommendations on technologies and new market structures and incentives that can create a future demand curve that more closely matches renewable generation patterns.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Advanced Load Identification and Management for Buildings: Cooperative Research and Development Final Report

The goal of this CRADA work is to support Eaton Innovation Center (Eaton) efforts to develop advanced load identification, management technologies, and solutions to reduce building energy consumption by providing fine granular visibility of energy usage information and safety protection of miscellaneous electric loads (MELs) in commercial and residential buildings. MELs load identification and prediction technology will be employed in a novel "Smart eOutlet*" to provide critical intelligence and information to improve the capability and functionality of building load analysis and design tools and building power management systems. The work scoped in this CRADA involves the following activities: development and validation of business value proposition for the proposed technologies through voice of customer investigation, market analysis, and third-party objective assessment; development and validation of energy saving impact as well as assessment of environmental and economic benefits; "smart eOutlet" concept design, prototyping, and validation; field validation of the developed technologies in real building environments. (*Another name denoted as "Smart Power Strip (SPS)" will be used as an alternative of the name "Smart eOutlet" for a clearer definition of the product market position in future work.)

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Hanford Apatite Treatability Test Report Errata: Apatite Mass Loading Calculation

The objective of this errata report is to document an error in the apatite loading (i.e., treatment capacity) estimate reported in previous apatite treatability test reports and provide additional calculation details for estimating apatite loading and barrier longevity. The apatite treatability test final report (PNNL-19572; Vermeul et al. 2010) documents the results of the first field-scale evaluation of the injectable apatite PRB technology. The apatite loading value in units of milligram-apatite per gram-sediment is incorrect in this and some other previous reports. The apatite loading in units of milligram phosphate per gram-sediment, however, is correct, and this is the unit used for comparison to field core sample measurements.

apatite↗

Load Modeling Transmission Research. Final Project Report

The research presented in this report primarily focuses on improving power system load models to better represent their impact on system behavior. The previous standard load model fails to capture the delayed voltage recovery events that are observed in the Southwest and elsewhere. These events are attributed to stalled air conditioner units after a fault. To gain a better understanding of their role in these events and to guide modeling efforts, typical air conditioner units were testing in laboratories. Using data obtained from these extensive tests, new load models were developed to match air conditioner behavior. An air conditioner model is incorporated in the new WECC composite load model. These models are used in dynamic studies of the West and can impact power transfer limits for California. Unit-level and system-level solutions are proposed as potential solutions to the delayed voltage recovery problem.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Residential Variable-Capacity Heat Pumps Sized to Heating Loads

Variable capacity heat pumps are an emerging technology offering significant energy savings potential and improved efficiency. With conventional single-speed systems, it is important to appropriately size heat pumps for the cooling load as over-sizing would result in cycling and insufficient latent capacity required for humidity control. These appropriately sized systems are often under-sized for the heating load and require inefficient supplemental electric resistance heat to meet the heating demand. Variable capacity heat pumps address these shortcomings by providing an opportunity to intentionally size systems for the dominant heating season load without adverse effects of cycling or insufficient dehumidification in the cooling season. This intentionally-sized system could result in significant energy savings in the heating season, as the need for inefficient supplemental electric resistance heat is drastically reduced. This is a continuation of a study evaluating the energy consumption of variable capacity heat pumps installed in two unoccupied research homes in Farragut, a suburb of Knoxville, Tennessee. In this particular study, space conditioning systems are intentionally sized for the heating season loads to provide an opportunity to understand and evaluate the impact this would have on electric resistance heat use and dehumidification. The results and conclusions drawn through this research are valid and specific for portions of the Southeastern and Midwestern United States falling in the mixed-humid climate zone. While other regions in the U.S. do not experience this type of climate, this work provides a basis for, and can help understand the implications of other climate zones on residential space conditioning energy consumption. The data presented here will provide a framework for fine tuning residential building EnergyPlus models that are being developed.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Characteristics and Performance of Existing Load Disaggregation Technologies

Non-intrusive load monitoring (NILM) or non-intrusive appliance load monitoring (NIALM) is an analytic approach to disaggregate building loads based on a single metering point. This advanced load monitoring and disaggregation technique has the potential to provide an alternative solution to high-priced traditional sub-metering and enable innovative approaches for energy conservation, energy efficiency, and demand response. However, since the inception of the concept in the 1980’s, evaluations of these technologies have focused on reporting performance accuracy without investigating sources of inaccuracies or fully understanding and articulating the meaning of the metrics used to quantify performance. As a result, the market for, as well as, advances in these technologies have been slowly maturing. To improve the market for these NILM technologies, there has to be confidence that the deployment will lead to benefits. In reality, every end-user and application that this technology may enable does not require the highest levels of performance accuracy to produce benefits. Also, there are other important characteristics that need to be considered, which may affect the appeal of NILM products to certain market targets (i.e. residential and commercial building consumers) and the suitability for particular applications. These characteristics include the following: 1) ease of use, the level of expertise/bandwidth required to properly use the product; 2) ease of installation, the level of expertise required to install along with hardware needs that impact product cost; and 3) ability to inform decisions and actions, whether the energy outputs received by end-users (e.g. third party applications, residential users, building operators, etc.) empower decisions and actions to be taken at time frames required for certain applications. Therefore, stakeholders, researchers, and other interested parties should be kept abreast of the evolving capabilities, uses, and characteristics of NILM that make them attractive for certain building environments and different classes of end-users. The intent of this report is to raise awareness of trending NILM approaches. Additionally, three existing technologies were acquired and evaluated using the Residential Building Stock Assessment (RBSA) owner-occupied test bed operated by the Northwest Energy Efficiency Alliance (NEEA) to understand performance accuracy of current NILM products under realistic conditions. Based on this field study experience, the characteristics exhibited by the NILM products included in the assessment are also discussed in this report in terms of ease of use, ease of installation, ability to inform decisions and actions. Results of the analysis performed to investigate the accuracy of the participating NILM products in estimating energy use of individual appliances are also presented.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Load Deflection of Dow Corning SE 1700 Face Centered Tetragonal Direct Ink Write Materials: Effect of Thickness and Filament Spacing

Dow Corning SE 1700 (reinforced polydimethylsiloxane) porous structures were made by direct ink writing (DIW) in a face centered tetragonal (FCT) configuration. The filament diameter was 250 μm. Structures consisting of 4, 8, or 12 layers were fabricated with center-to-center filament spacing (“road width” (RW)) of 475, 500, 525, 550, or 575 μm. Three compressive load-unload cycles to 2000 kPa were performed on four separate areas of each sample; three samples of each thickness and filament spacing were tested. At a given strain during the third loading phase, stress varied inversely with porosity. At 10% strain, the stress was nearly independent of the number of layers (i.e., thickness). At higher strains (20- 40%), the stress was highest for the 4-layer structure; the 8- and 12-layer structures were nearly equivalent suggesting that the load deflection is independent of number of layers above 8 layers. Intra-and inter-sample variability of the load deflection response was higher for thinner and less porous structures.

36 MATERIALS SCIENCE↗

Assessment of Industrial Load for Demand Response across U.S. Regions of the Western Interconnect

Demand response has the ability to both increase power grid reliability and potentially reduce operating system costs. Understanding the role of demand response in grid modeling has been difficult due to complex nature of the load characteristics compared to the modeled generation and the variation in load types. This is particularly true of industrial loads, where hundreds of different industries exist with varying availability for demand response. We present a framework considering industrial loads for the development of availability profiles for demand response that can provide more regional understanding and can be inserted into analysis software for further study.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Loads as a Resource: Frequency Responsive Demand

Current power grid operation predominantly relies on scheduling and regulating generation resources to supply loads and balance load changes. Due to the inherent intermittency of renewable energy, more flexible and fast ramping capacity is required to compensate for the uncertainty and variability introduced by renewable energy resources. With the advancement of information technologies, power system end-use loads are becoming more agile and can participate in provision of balancing energy and other grid services. The use of demand response can greatly reduce the required generation reserve in a clean and environmentally friendly way. In this report, a new frequency responsive load (FRL) controller was proposed based on the GFA controller, which can respond to both over and under-frequency events. A supervisory control was introduced to coordinate the autonomous response from FRLs in order to overcome the issues of excessive system response due to high penetration of FRLs. The effectiveness of the proposed FRL controller was demonstrated by large-scale simulation studies on the WECC system. Specifically, the FRLs were deployed in the WECC system at different penetration levels to analyze the performance of the proposed strategy both with and without supervisory level control. While both methods have their own advantages, the case without supervisory control could lead to system-wide instability depending on the size of the contingency and the number of FRLs deployed in the system. In addition, the voltage impacts of this controller on distribution system were also carefully investigated. Finally, a preliminary measurement and verification approach was also developed.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Evaluating Moisture Control of Variable-Capacity Heat Pumps in Mechanically Ventilated, Low-Load Homes in Climate Zone 2A

The well-sealed, highly insulated building enclosures constructed by today's home building industry coupled with efficient lighting and appliances are achieving significantly reduced heating and cooling loads. These low-load homes can present a challenge when selecting appropriate space-conditioning equipment. Conventional, fixed-capacity heating and cooling equipment is often oversized for small homes, causing increased first costs and operating costs. Even if fixed-capacity equipment can be properly specified for peak loads, it remains oversized for use during much of the year. During these part-load cooling hours, oversized equipment meets the target dry-bulb temperatures very quickly, often without sufficient opportunity for moisture control. The problem becomes more acute for high-performance houses in humid climates when meeting ASHRAE Standard 62.2 recommendations for wholehouse mechanical ventilation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Analyzing the Energy Performance, Wind Loading, and Costs of Photovoltaic Slat Modules on Commercial Rooftops

NREL studied a new type of photovoltaic (PV) module configuration wherein multiple narrow, tilted slats are mounted in a single frame. Each slat of the PV slat module contains a single row of cells and is made using ordinary crystalline silicon PV module materials and processes, including a glass front sheet and weatherproof polymer encapsulation. Compared to a conventional ballasted system, a system using slat modules offer higher energy production and lower weight at lower LCOE. The key benefits of slat modules are reduced wind loading, improved capacity factor and reduced installation cost. First, the individual slats allow air to flow through, which reduce wind loading. Using PV performance modeling software, we compared the performance of an optimized installation of slats modules to a typical installation of conventional modules in a ballasted rack mounting system. Based on the results of the performance modeling two different row tilt and spacing were tested in a wind tunnel. Scaled models of the PV Slat modules were wind tunnel tested to quantify the wind loading of a slat module system on a commercial rooftop, comparing the results to conventional ballasted rack mounted PV modules. Some commercial roofs do not have sufficient reserve dead load capacity to accommodate a ballasted system. A reduced ballast system design could make PV system installation on these roofs feasible for the first time without accepting the disadvantages of penetrating mounts. Finally, technoeconomic analysis was conducted to enable an economic comparison between a conventional commercial rooftop system and a reduced-ballast slat module installation.

14 SOLAR ENERGY↗

Verification Problems for Parameterized Load Curves in DYNA3D

Two verification problems are presented which test a set of newly implemented load curve features in the explicit finite element program DYNA3D. Each test consists of a single element, with the velocity of each node specified via a different load curve type. The first test covers initialization and run-time execution of these new features, while the second test covers redefinition of load curves upon restart. The proposed problems may be easily extended to test additional load curve features.

42 ENGINEERING↗

Performance of a Biomass Boiler in a Load Profile Test

In this report, results are presented of the performance evaluation of a modern residential cordwood-fired hydronic heater. This unit was tested under a specific load and operating profile that includes cold start, four load levels, reload, and cycling in response to an emulated thermostat. The protocol can be completed in a single day, which allows for replicate runs in about a week of testing. This can characterize variability with greater confidence than current methods used in certification testing, reduces time to conduct certification tests, and moves toward greater representative operations as the test includes start-up and requires boilers to respond to a variety of heat loads in a manner that better reflects day-to-day operations. Detailed in the report are the results of triplicate testing of one U.S. Environmental Protection Agency-certified cordwood-fired outdoor wood boiler. Cold start emissions were the greatest among all testing periods. In triplicate testing, emission output values for the cold start tests were 9.52, 4.74, and 6.63 lb/MMBtu of output for Test 1, 2, and 3, respectively. The overall emission output values for Test 1, 2, and 3 were 0.44, 0.34, and 0.19 lb/MMBtu of output, respectively. Additionally, the work in this project found significant differences in filter sampling methods with different integrated time periods. The use of real-time particulate matter emission measurement devices was explored. Specifically, sampling with one filter over a long test with various phases (cold starts, reloads, high and low burns) yielded lower particulate mass than sampling phase by phase (one filter for high burns, one filter for low burns, etc.). Perhaps the use of a real-time particulate matter emission measurement device can be used to distinguish different burn phases without having to change filters multiple times throughout a varied load test method

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An Evaluation of Electricity Net Load Profiles and the Baseload Generation Concept

This paper investigates the amount of baseload generation that would be displaced due to renewable resources being implemented to meet state renewable portfolio standards (RPS) in the following regions: the Midwest Independent System Operator (MISO), the PJM regional transmission organization (RTO), the Electric Reliability Council of Texas (ERCOT), and the California ISO (CAISO). Modeling of these regions was done in Promod, a security constrained economic dispatch (SCED) model, for the years 2016-2030, to compare scenarios with and without the two primary intermittent renewable resources (solar and wind) attributable to the RPS regulations implemented in each state. In addition, a new statistical approach was developed for evaluating the variability in net load shapes caused by these two intermittent resources. The load variability index (LVI) was developed to apply to the hourly net load profiles for each day as a means of comparing variability in net loads.

14 SOLAR ENERGY↗