Search NASA⌕ Search

SEARCH · Search NASA

Results for “LOGS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,783 records · Page 99

Profiling the Usage of an Extreme-Scale Archival Storage System

Profiling the archival storage system in scientific computing environments has received much less attention compared to the parallel file system, but is equally important since it stores the final data products safely, for a long duration. In this paper, we analyze eight years worth of data transfer logs for accessing the archival file system (HPSS) in the Oak Ridge Leadership Computing Facility (OLCF), which has been hosting the world's largest supercomputers and file systems. Our analysis encompasses about 135 million data transfer activities to the 80 PB High Performance Storage System (HPSS), between 2010 and 2017. We analyze the logs from several dimensions, including studying the workload characteristics (e.g., access patterns, frequency of accesses and temporal behavior), file system characteristics (e.g., directory depth, file system scaling trends, file types), and scientific user behavior (e.g., domain-specific usage and organization). Based on the analysis, we derive insights into the future evolution of the archive in terms of provisioning, desired features and functionality from the archive software, role and right sizing of the archive tiers, quota management, and the importance of smart and efficient metadata and storage management. We believe our study will prove useful for both operating current archival storage and better provisioning future systems.

Sim, Hyogi↗

An Automated Vehicle Fuel Economy Benefits Evaluation Framework Using Real-World Travel and Traffic Data

Increasing automation is a consistent development trend in the automobile industry. However, real-world evaluation of the operational and energy consumption differences between automated vehicles and comparable manually driven vehicles has been limited. This study helps fill the information gap by comparing the operation and fuel economy of vehicles in adaptive cruise control (ACC) and non-ACC modes based on large-scale field test data collected by Volvo Car Corporation (Volvo Cars) from vehicles traveling on the designated 'Drive Me' project road network in Gothenburg, Sweden. The test vehicles' travel data are classified by driving mode (ACC vs. non-ACC) and driving conditions, which refer to traffic speed and road grade in this study. The results from the data logging fleet are used to estimate the aggregate fuel consumption differences at the Drive Me road-network level for vehicles traveling in ACC vs. non-ACC mode based on appropriately weighting the total amount of travel that took place on the network under different driving conditions. At the ACC penetration levels observed in the field test data, vehicles tended to drive more smoothly in ACC mode than in non-ACC mode. The corresponding travel-weighted fuel consumption rate for vehicles in ACC mode was about 5%-7% lower than for vehicles in non-ACC mode when traveling at similar conditions. Sensitivity analyses impart confidence in this result, and in the future, the established evaluation framework could be used to objectively quantify potential on-road fuel consumption impacts from vehicles with even higher levels of automated driving capability.

33 ADVANCED PROPULSION SYSTEMS↗

A Scientific Data Provenance Harvester for Distributed Applications

Data provenance provides a way for scientists to observe how experimental data originates, conveys process history, and explains influential factors such as experimental rationale and associated environmental factors from system metrics measured at runtime. The US Department of Energy Office of Science Integrated end-to-end Performance Prediction and Diagnosis for Extreme Scientific Workflows (IPPD) project has developed a provenance harvester that is capable of collecting observations from file based evidence typically produced by distributed applications. To achieve this, file based evidence is extracted and transformed into an intermediate data format inspired in part by W3C CSV on the Web recommendations, called the Harvester Provenance Application Interface (HAPI) syntax. This syntax provides a general means to pre-stage provenance into messages that are both human readable and capable of being written to a provenance store, Provenance Environment (ProvEn). HAPI is being applied to harvest provenance from climate ensemble runs for Accelerated Climate Modeling for Energy (ACME) project funded under the U.S. Department of Energy’s Office of Biological and Environmental Research (BER) Earth System Modeling (ESM) program. ACME informally provides provenance in a native form through configuration files, directory structures, and log files that contain success/failure indicators, code traces, and performance measurements. Because of its generic format, HAPI is also being applied to harvest tabular job management provenance from Belle II DIRAC scheduler relational database tables as well as other scientific applications that log provenance related information.

Stephan, Eric G.↗

A Butterfly-Accelerated Volume Integral Equation Solver for Broad Permittivity and Large-Scale Electromagnetic Analysis

In this work, a butterfly-accelerated volume integral equation (VIE) solver is proposed for fast and accurate electromagnetic (EM) analysis of scattering from heterogeneous objects. The proposed solver leverages the hierarchical off-diagonal butterfly (HOD-BF) scheme to construct the system matrix and obtain its approximate inverse, used as a preconditioner. Complexity analysis and numerical experiments validate the O(N log 2 N) construction cost of the HOD-BF-compressed system matrix and O(N log 1.5 N) inversion cost for the preconditioner, where N is the number of unknowns in the high-frequency EM scattering problem. For many practical scenarios, the proposed VIE solver requires less memory and computational time to construct the system matrix and obtain its approximate inverse compared to a H matrix-accelerated VIE solver. The accuracy and efficiency of the proposed solver have been demonstrated via its application to the EM analysis of large-scale canonical and real-world structures comprising of broad permittivity values and involving millions of unknowns.

42 ENGINEERING↗

GraphCH: A Deep Framework for Assessing Cyber-Human Aspects in Insider Threat Detection

Insider threat is one of the most damaging cyber attacks that could cause the loss of intellectual property and enterprise data security breaches. Action sequence data such as host logs are used to investigate such threats and develop anomaly-based AI detectors. However, insider threat actions are similar to legitimate user activities, causing AI detectors to fail and suffer from high false alarm rates. Therefore, user cyber activity logs are inadequate to fully unfold insider threats. In this study, we adopt human psychological principles of risk-taking and impulsiveness along with host data to assess the influence and usefulness of human behavioral aspects in insider threat detection. Here, we hypothesize that individuals' impulsive and risk-taking behavior correlates with cyberspace activities. To validate our hypothesis, we conducted an IRB-approved study recruiting 35 participants who work in a large U.S. university and collected their cyber and psychological data for 90 days. Host and human-behavioral data analysis and mapping indicate that impulsive and risk-taking users trigger more system errors causing (un)intentional insider threats and are susceptible to attackers' social engineering and cognitive hacking. Utilizing cyber-human aspects, we introduce a Cyber-Human Graph Neural Network (GNN) based framework GraphCH to identify abnormal user behaviors and detect insider threats.

97 MATHEMATICS AND COMPUTING↗

Investigating the Effects of Individual Neutron-Induced Defects in Bipolar Junction Transistors

Here, this study investigates neutron-induced displacement damage in Bipolar Junction Transistors (BJTs) using TCAD models informed by Deep-Level-Transient-Spectroscopy (DLTS) data. These models are calibrated and validated against experimental measurements performed at various neutron fluences. Both npn and pnp transistor configurations are studied to analyze the effects of individual traps on carrier recombination and base leakage currents. In npn transistors, deep traps (0.42 eV from the conduction band) dominate at low voltages, while shallow traps (0.17 eV from the conduction band) become prominent at higher voltages. Conversely, pnp transistors have base leakage current predominantly due to deep-level traps. The study observes a notable trend in trap density versus fluence, characterized by a linear relationship on a log-log scale. These insights into defect evolution under radiation conditions are crucial for optimizing semiconductor device reliability and performance in radiation-prone environments.

42 ENGINEERING↗

HIDES: Hybrid Intrusion Detector for Energy Systems

The establishment of a resilient electric grid accompanied by a secure communications network is an ongoing battle as advanced persistent threats continue to exploit existing vulnerabilities in legacy supervisory control and data acquisition system (SCADA) infrastructure. Traditional intrusion detection systems (IDSs) lack consistent performance because of the continuously evolving attack surface of SCADA systems. These shortcomings can be overcome by integrating logical system behavior, protocol-specific knowledge, and data-based learning to develop a comprehensive IDS solution. In this paper, we present a Hybrid Intrusion Detector for Energy Systems by integrating a network-based IDS, state-of-the-art machine learning-based IDS, and model-based IDS to detect unknown and stealthy cyberattacks targeting the SCADA networks. The proposed IDS uses synchrophasor measurements and cyber logs to learn patterns of different scenarios based on spatiotemporal behaviors of power systems. As a proof of concept, we implement and validate the proposed IDS by leveraging resources available at the National Renewable Energy Laboratory's Energy Systems Integration Facility test bed. Experimental results show promising performance in detecting cyberattacks while providing realtime visualization of power system measurements and cyber logs.

machine-learning intrusion detection system↗

Melting temperature measurement of refractory oxide ceramics as a function of oxygen fugacity using containerless methods

An aerodynamic conical nozzle levitator (CNL) has been used to measure the melting temperatures of refractory ceramics. The well-established method of cooling traces has been adapted to allow measurements for air-sensitive samples using a controlled atmosphere, where the oxygen partial pressure can be adjusted and monitored in real time. In this study, we explain the details of a system that we developed for use at the Spallation Neutron Source (Oak Ridge National Laboratory). Measurements of the melting behavior of (Fe,Cr,Al) 3 O 4 spinels were made between log (PO 2 (atm)) of -0.7 and -5. The melting temperature of hercynite is found to be oxygen potential dependent, ranging between 1692 and 1767°C at log (PO 2 ) values from -4.42 to -0.70.

36 MATERIALS SCIENCE↗

HIV influences clustering and intracellular replication of hepatitis C virus

We report HCV and HIV coinfection is common and HIV leads to increased HCV viraemia and accelerated disease progression. However, the biological basis of this interaction remains poorly understood and little is known about the impact of HIV on HCV replication at the cellular level. We analysed HCV RNA, based on single-cell laser-capture microdissection, in liver biopsies from monoinfected (n = 4) and HCV/HIV-coinfected (n = 5) participants. HCV RNA was assayed in 3200 hepatocytes with information of spatial position. We compared HCV RNA levels and clustering properties of infection between mono- and coinfected participants, and developed a mathematical model of infection. Although the median plasma HCV RNA level and the fraction of infected cells were comparable in monoinfected (7.0 log 10 IU/mL and ~ 30%) and coinfected (7.3 log 10 IU/mL and ~ 40%) participants, the median HCV RNA per infected hepatocyte in monoinfected (2.8IU) was significantly lower than in coinfected (8.2IU) participants (p = .03). Clustering of infected cells was more prominent in monoinfected participants (91% of samples) than in coinfected participants (~48%), p = .0045, suggesting that spatial spread may be influenced by HIV coinfection. Interestingly, when clustering does occur, the size of clusters is similar in both types of infection. A mathematical model of infection suggested that HIV allows higher intracellular accumulation of HCV RNA by impeding the export of HCV RNA. Our observations show that HIV coinfection impacts intracellular accumulation of HCV RNA and the clustering of HCV-infected cells, but to a less extent the fraction of HCV-infected cells.

59 BASIC BIOLOGICAL SCIENCES↗

Some implications of linear-quadratic-linear radiation dose-response with regard to hypofractionation

Recent technological advances enable radiation therapy to be delivered in a highly conformal manner to targets located almost anywhere in the body. This capability has renewed the clinical interest in hypofractionation wherein the tumor is delivered a few fractions of very large dose per fraction. Extrapolating clinical experience from conventional regimens to fractions of high dose is important to designing hypofractionated treatments. The concept of biologically effective dose (BED) based on the linear-quadratic (LQ) formulation e{sup -({alpha}D+{beta}D{sup 2})} is a useful tool for intercomparing conventional fractionations but may be hampered if the value of {alpha}/{beta} is dose range dependent and/or when extrapolating to fractions of high dose because the LQ curve bends continuously on the log-linear plot. This does not coincide with what is observed experimentally in many clonogenic cell survival studies at high dose wherein radiation dose-response relationships more closely approximate a straight line. Intercomparison of conventional fractionations with hypofractionated regimens may benefit from BED calculations which instead use a dose range independent linear-quadratic-linear (LQ-L) formulation which better fits the experimental data across a wider range of dose. The dosimetric implications of LQ-L are explored using a simple model which requires only the specification of a dose D{sub T} at which the LQ curve transitions to final linearity and the log{sub e} cell kill per Gy in the final linear portion of the survival curve at high dose. It is shown that the line tangent to the LQ curve at transition dose D{sub T} can often be used to approximate the final slope of the dose response curve. When D{sub T}=2{alpha}/{beta} Gy, the line tangent to the LQ curve at D{sub T} intersects the e{sup -{alpha}}{sup D} and e{sup -{beta}}{sup D{sup 2}} curves at dose {alpha}/{beta} Gy and also closely fits the linear response in the high dose region of some classic in vitro cell survival curves for which the value of {alpha}/{beta} is low. It is hypothesized that D{sub T} will increase as the magnitude of {alpha}/{beta} increases. Examples are presented illustrating how to recognize LQ-L behavior in multifraction isoeffect studies of late responses such as spinal cord and lung. When planning hypofractionated regimens involving reactions with low {alpha}/{beta}, recognizing LQ-L behavior could be important because the dose-response is likely to transition to final linearity within the contemplated range of hypofractional doses.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A {gamma} dose distribution evaluation technique using the k-d tree for nearest neighbor searching

Purpose: The authors propose an algorithm based on the k-d tree for nearest neighbor searching to improve the {gamma} calculation time for 2D and 3D dose distributions. Methods: The {gamma} calculation method has been widely used for comparisons of dose distributions in clinical treatment plans and quality assurances. By specifying the acceptable dose and distance-to-agreement criteria, the method provides quantitative measurement of the agreement between the reference and evaluation dose distributions. The {gamma} value indicates the acceptability. In regions where {gamma}{<=}1, the predefined criterion is satisfied and thus the agreement is acceptable; otherwise, the agreement fails. Although the concept of the method is not complicated and a quick naieve implementation is straightforward, an efficient and robust implementation is not trivial. Recent algorithms based on exhaustive searching within a maximum radius, the geometric Euclidean distance, and the table lookup method have been proposed to improve the computational time for multidimensional dose distributions. Motivated by the fact that the least searching time for finding a nearest neighbor can be an O(log N) operation with a k-d tree, where N is the total number of the dose points, the authors propose an algorithm based on the k-d tree for the {gamma} evaluation in this work. Results: In the experiment, the authors found that the average k-d tree construction time per reference point is O(log N), while the nearest neighbor searching time per evaluation point is proportional to O(N{sup 1/k}), where k is between 2 and 3 for two-dimensional and three-dimensional dose distributions, respectively. Conclusions: Comparing with other algorithms such as exhaustive search and sorted list O(N), the k-d tree algorithm for {gamma} evaluation is much more efficient.

61 RADIATION PROTECTION AND DOSIMETRY↗

Reference air kerma and kerma-area product as estimators of peak skin dose for fluoroscopically guided interventions

Purpose: To determine more accurate regression formulas for estimating peak skin dose (PSD) from reference air kerma (RAK) or kerma-area product (KAP). Methods: After grouping of the data from 21 procedures into 13 clinically similar groups, assessments were made of optimal clustering using the Bayesian information criterion to obtain the optimal linear regressions of (log-transformed) PSD vs RAK, PSD vs KAP, and PSD vs RAK and KAP. Results: Three clusters of clinical groups were optimal in regression of PSD vs RAK, seven clusters of clinical groups were optimal in regression of PSD vs KAP, and six clusters of clinical groups were optimal in regression of PSD vs RAK and KAP. Prediction of PSD using both RAK and KAP is significantly better than prediction of PSD with either RAK or KAP alone. The regression of PSD vs RAK provided better predictions of PSD than the regression of PSD vs KAP. The partial-pooling (clustered) method yields smaller mean squared errors compared with the complete-pooling method.Conclusion: PSD distributions for interventional radiology procedures are log-normal. Estimates of PSD derived from RAK and KAP jointly are most accurate, followed closely by estimates derived from RAK alone. Estimates of PSD derived from KAP alone are the least accurate. Using a stochastic search approach, it is possible to cluster together certain dissimilar types of procedures to minimize the total error sum of squares.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

3D modeling of effects of increased oxygenation and activity concentration in tumors treated with radionuclides and antiangiogenic drugs

Purpose: Formation of new blood vessels (angiogenesis) in response to hypoxia is a fundamental event in the process of tumor growth and metastatic dissemination. However, abnormalities in tumor neovasculature often induce increased interstitial pressure (IP) and further reduce oxygenation (pO{sub 2}) of tumor cells. In radiotherapy, well-oxygenated tumors favor treatment. Antiangiogenic drugs may lower IP in the tumor, improving perfusion, pO{sub 2} and drug uptake, by reducing the number of malfunctioning vessels in the tissue. This study aims to create a model for quantifying the effects of altered pO{sub 2}-distribution due to antiangiogenic treatment in combination with radionuclide therapy. Methods: Based on experimental data, describing the effects of antiangiogenic agents on oxygenation of GlioblastomaMultiforme (GBM), a single cell based 3D model, including 10{sup 10} tumor cells, was developed, showing how radionuclide therapy response improves as tumor oxygenation approaches normal tissue levels. The nuclides studied were {sup 90}Y, {sup 131}I, {sup 177}Lu, and {sup 211}At. The absorbed dose levels required for a tumor control probability (TCP) of 0.990 are compared for three different log-normal pO{sub 2}-distributions: {mu}{sub 1} = 2.483, {sigma}{sub 1} = 0.711; {mu}{sub 2} = 2.946, {sigma}{sub 2} = 0.689; {mu}{sub 3} = 3.689, and {sigma}{sub 3} = 0.330. The normal tissue absorbed doses will, in turn, depend on this. These distributions were chosen to represent the expected oxygen levels in an untreated hypoxic tumor, a hypoxic tumor treated with an anti-VEGF agent, and in normal, fully-oxygenated tissue, respectively. The former two are fitted to experimental data. The geometric oxygen distributions are simulated using two different patterns: one Monte Carlo based and one radially increasing, while keeping the log-normal volumetric distributions intact. Oxygen and activity are distributed, according to the same pattern. Results: As tumor pO{sub 2} approaches normal tissue levels, the therapeutic effect is improved so that the normal tissue absorbed doses can be decreased by more than 95%, while retaining TCP, in the most favorable scenario and by up to about 80% with oxygen levels previously achieved in vivo, when the least favourable oxygenation case is used as starting point. The major difference occurs in poorly oxygenated cells. This is also where the pO{sub 2}-dependence of the oxygen enhancement ratio is maximal. Conclusions: Improved tumor oxygenation together with increased radionuclide uptake show great potential for optimising treatment strategies, leaving room for successive treatments, or lowering absorbed dose to normal tissues, due to increased tumor response. Further studies of the concomitant use of antiangiogenic drugs and radionuclide therapy therefore appear merited.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Optimized generation of high resolution breast anthropomorphic software phantoms

Purpose: The authors present an efficient method for generating anthropomorphic software breast phantoms with high spatial resolution. Employing the same region growing principles as in their previous algorithm for breast anatomy simulation, the present method has been optimized for computational complexity to allow for fast generation of the large number of phantoms required in virtual clinical trials of breast imaging. Methods: The new breast anatomy simulation method performs a direct calculation of the Cooper's ligaments (i.e., the borders between simulated adipose compartments). The calculation corresponds to quadratic decision boundaries of a maximum a posteriori classifier. The method is multiscale due to the use of octree-based recursive partitioning of the phantom volume. The method also provides user-control of the thickness of the simulated Cooper's ligaments and skin. Results: Using the proposed method, the authors have generated phantoms with voxel size in the range of (25-1000 {mu}m){sup 3}/voxel. The power regression of the simulation time as a function of the reciprocal voxel size yielded a log-log slope of 1.95 (compared to a slope of 4.53 of our previous region growing algorithm). Conclusions: A new algorithm for computer simulation of breast anatomy has been proposed that allows for fast generation of high resolution anthropomorphic software phantoms.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The relationship between anatomic noise and volumetric breast density for digital mammography

Purpose: The appearance of parenchymal/stromal patterns in mammography have been characterized as having a Wiener power spectrum with an inverse power-law shape described by the exponential parameter, {beta}. The amount of fibroglandular tissue, which can be quantified in terms of volumetric breast density (VBD), influences the texture and appearance of the patterns formed in a mammogram. Here, a large study is performed to investigate the variations in {beta} in a clinical population and to indicate the relationship between {beta} and breast density. Methods: From a set of 2686 cranio-caudal normal screening mammograms, the parameter {beta} was extracted from log-log fits to the Wiener spectrum over the range 0.15-1 mm{sup -1}. The Wiener spectrum was calculated from regions of interest in the compression paddle contact region of the breast. An in-house computer program, Cumulus V, was used to extract the volumetric breast density and identify the compression paddle contact regions of the breast. The Wiener spectra were calculated with and without modulation transfer function (MTF) correction to determine the impact of VBD on the intrinsic anatomic noise. Results: The mean volumetric breast density was 25.5% ({+-}12.6%) over all images. The mean {beta} following a MTF correction which decreased the {beta} slightly ( Almost-Equal-To -0.08) was found to be 2.87. Varying the maximum of the spatial frequency range of the fits from 0.7 to 1.0, 1.25 or 1.5 mm{sup -1} showing small decreases in the result, although the effect of the quantum noise power component on reducing {beta} was clearly observed at 1.5 mm{sup -1}. Conclusions: The texture parameter, {beta}, was found to increase with VBD at low volumetric breast densities with an apparent leveling off at higher densities. The relationship between {beta} and VBD measured here can be used to create probabilistic models for computer simulations of detectability. As breast density is a known risk predictor for breast cancer, the correlation between {beta} and VBD suggests that {beta} may provide predictive information and this will be investigated in the future.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-D-BRE-04: Evaluating the Dose Accuracy of a 2D Ion Chamber Array in High Dose Rate Pencil Beam Scanning Proton Beam

Purpose: To evaluate the absolute dose accuracy of the PTW Octavius 729 XDR 2D ion chamber array at a high dose rate pencil beam scanning proton therapy facility. Methods: A set of 18 plans were created in our treatment planning system, each of which comprising a unique combination of field sizes (FS), length of spread out of Bragg peaks (SOBP) and depths. The parameters used were: FS of 5×5cm{sup 2}, 10×10cm{sup 2} and 15×15cm{sup 2}; flat SOBP of 5cm and 10cm; and isocenter depths of 10cm, 15cm and 20cm, which coincides with the center of the SOBP. The 2D array detector was positioned at the machine isocenter and the appropriate amount of solid water was used to match the planned depths of 10, 15 and 20 cm water equivalent depth. Subsequently, we measured the absolute dose at isocenter using a CC04 ion chamber in a 1D water tank. Both 2D array and CC04 were previously cross calibrated. We also collected the MU rates used by our proton machine from the log files. Results: The relative differences between the CC04 and the 2D array can be summarized into two groups, one with 5 cm SOBP and another with 10 cm SOBP. Plotting these datasets against FS shows that the 2D array response for high dose rate fields (FS of 5×5cm{sup 2} and 5cm SOBP) can be up to 2% lower. Similarly, plotting them against isocenter depths reveals the detector's response can be up to 2% lower for higher energy beams (about 200MeV nominal). The MU rate found in the machine log files for 5cm SOBP's were as high as twice the MU rate for the 10cm SOBP. Conclusion: The 2D array dose response showed a dose rate effect in scanning pencil beam delivery, which needs to be corrected to achieve a better dose accuracy.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-T-100: Designing a QA Tool for Enhance Dynamic Wedges Based On Dynalog Files

Purpose: A robust quality assurance (QA) program for computer controlled enhanced dynamic wedge (EDW) has been designed and tested. Calculations to perform such QA test is based upon the EDW dynamic log files generated during dose delivery. Methods: Varian record and verify system generates dynamic log (dynalog) files during dynamic dose delivery. The system generated dynalog files contain information such as date and time of treatment, energy, monitor units, wedge orientation, and type of treatment. It also contains the expected calculated segmented treatment tables (STT) and the actual delivered STT for the treatment delivery as a verification record. These files can be used to assess the integrity and precision of the treatment plan delivery. The plans were delivered with a 6 MV beam from a Varian linear accelerator. For available EDW angles (10°, 15°, 20°, 25°, 30°, 45°, and 60°) Varian STT values were used to manually calculate monitor units for each segment. It can also be used to calculate the EDW factors. Independent verification of fractional MUs per segment was performed against those generated from dynalog files. The EDW factors used to calculate MUs in TPS were dosimetrically verified in solid water phantom with semiflex chamber on central axis. Results: EDW factors were generated from the STT provided by Varian and verified against practical measurements. The measurements were in agreement of the order of 1 % to the calculated EDW data. Variation between the MUs per segment obtained from dynalog files and those manually calculated was found to be less than 2%. Conclusion: An efficient and easy tool to perform routine QA procedure of EDW is suggested. The method can be easily implemented in any institution without a need for expensive QA equipment. An error of the order of ≥2% can be easily detected.

60 APPLIED LIFE SCIENCES↗

SU-E-T-406: Use of TrueBeam Developer Mode and API to Increase the Efficiency and Accuracy of Commissioning Measurements for the Varian EDGE Stereotactic Linac

Purpose: The Varian EDGE machine is a new stereotactic platform, combining Calypso and VisionRT localization systems with a stereotactic linac. The system includes TrueBeam DeveloperMode, making possible the use of XML-scripting for automation of linac-related tasks. This study details the use of DeveloperMode to automate commissioning tasks for Varian EDGE, thereby improving efficiency and measurement consistency. Methods: XML-scripting was used for various commissioning tasks,including couch model verification,beam-scanning,and isocenter verification. For couch measurements, point measurements were acquired for several field sizes (2×2,4×4,10×10cm{sup 2}) at 42 gantry angles for two couch-models. Measurements were acquired with variations in couch position(rails in/out,couch shifted in each of motion axes) compared to treatment planning system(TPS)-calculated values,which were logged automatically through advanced planning interface(API) scripting functionality. For beam scanning, XML-scripts were used to create custom MLC-apertures. For isocenter verification, XML-scripts were used to automate various Winston-Lutz-type tests. Results: For couch measurements, the time required for each set of angles was approximately 9 minutes. Without scripting, each set required approximately 12 minutes. Automated measurements required only one physicist, while manual measurements required at least two physicists to handle linac positions/beams and data recording. MLC apertures were generated outside of the TPS,and with the .xml file format, double-checking without use of TPS/operator console was possible. Similar time efficiency gains were found for isocenter verification measurements Conclusion: The use of XML scripting in TrueBeam DeveloperMode allows for efficient and accurate data acquisition during commissioning. The efficiency improvement is most pronounced for iterative measurements, exemplified by the time savings for couch modeling measurements(approximately 10 hours). The scripting also allowed for creation of the files in advance without requiring access to TPS. The API scripting functionality enabled efficient creation/mining of TPS data. Finally, automation reduces the potential for human error in entering linac values at the machine console,and the script provides a log of measurements acquired for each session. This research was supported in part by a grant from Varian Medical Systems, Palo Alto, CA.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗