Search NASA⌕ Search

SEARCH · Search NASA

Results for “MAGNETIC CONFINEMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,783 records · Page 99

Three-dimensional equilibria and island energy transport due to resonant magnetic perturbation edge localized mode suppression on DIII-D

In this research, we conducted experiments in the DIII-D tokamak that show that the plasma responds to resonant magnetic perturbations (RMPs) with toroidalmode numbers of n=2 and n=3 without field line reconnection, consistent with resistive magnetohydrodynamic predictions, while a strong nonlinear bifurcation is apparent when edge localized modes(ELMs) are suppressed. The magnetic response associated with this bifurcation is localized to the high field side of the machine and exhibits a dominant n=1 component despite the application of a constant amplitude, slowly toroidally rotating, n=2 applied field. The n=1 mode is born locked to the vacuum vessel wall, while the n=2 mode is entrained to the rotating field. Based on these magnetic response measurements and Thomson scattering measurements of flattening of the electron temperature profile, it is likely that these modes are magnetic island chains near the H-mode pedestal. The reduction in ∇Te occurs near the q=4 and 5 rational surfaces, suggesting five unique islands are possible (m=8, 9, or 10 for n=2) and (m=4 or 5 for n=1). In all cases, the island width is estimated to be 2–3 cm. The Chang-Callen calculated confinement degradation due to the presence of an individual island of this size is 8%–12%, which is close to the 13%–14% measured between the ELMs and suppressed states. In conclusion, this suggests that edge tearing modes may alter the pedestal causing peeling-ballooning stability during RMP induced ELM suppression.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Discriminating between two reformulations of SU(3) Yang-Mills theory on a lattice

In order to investigate quark confinement, we give a new reformulation of the SU (N) Yang-Mills theory on a lattice and present the results of the numerical simulations of the SU (3) Yang-Mills theory on a lattice. The numerical simulations include the derivation of the linear potential for static interquark potential, i.e., non-vanishing string tension, in which the “Abelian” dominance and magnetic monopole dominance are established, confirmation of the dual Meissner effect by measuring the chromoelectric flux tube between quark-antiquark pair, the induced magnetic-monopole current, and the type of dual superconductivity, etc.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Plasma physics effects on thermonuclear burn rate in the presence of hydrodynamic mix

Hydrodynamic mix can significantly degrade thermonuclear burn rate in an inertial confinement fusion (ICF) target. Successful mitigation requires a detailed understanding of the physical mechanisms by which mix affects burn. Here we summarize the roles of three distinct plasma physics effects on burn rate. The first is the well-known effect of enhanced thermal energy loss from the hot spot and the mitigating role of self-generated or externally-applied magnetic field. The second is the fuel ion separation via inter-species ion diffusion driven by the powerful thermodynamic forces exacerbated by mix during the implosion process. The third is the fusion reactivity modification by fast ion transport in a mix-dominated ICF target, where hot plasma is intermingled with cold fuel.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Predictive turbulence-driven flux model of scrape-off layer widths across confinement regimes in tokamaks

Reliable scrape-off layer (SOL) profile decay lengths predictions are needed to design and operate future tokamaks. The present manuscript describes a new model based on turbulent transport that is able to predict SOL widths for both L-mode and H-mode plasmas. The model is based upon the sheared-spectral filament paradigm (Peret et al (WEST Team) 2022 Phys. Plasmas 29 072306), however, incorporating the effects of thermal transport in order to calculate the parallel heat fluxes. The effects of magnetic shear and ExB shear on the cross-field transport are crucial to explain the shorter SOL decay lengths found in H-mode. The model is validated against a database of thousands of DIII-D L-mode and H-mode SOL profiles. We also calculate SOL decay length predictions in terms of plasma and engineer control parameters, which are in agreement with the multi-machine empirical H-mode scaling (Eich et al (ASDEX Upgrade Team and JET EFDA Contributors) 2013 Nucl. Fusion 53 093031), however, with an additional device geometry dependence. ITER SOL width predictions by the model are 3 times higher than the empirical scaling.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Correlation between antiferromagnetic and Mott states in spin orbit coupled Sr 2 Ir O 4 : A study of Sr 2 Ir 1 – x M x O 4 ( M = Fe or Co)

Sr 2 IrO 4 is an archetypal spin-orbit-coupled Mott insulator with an antiferromagnetic state below 240 K. Here we report results of our study on single crystals of Sr 2 Ir 1–x Fe x O 4 (0 ≤ x < 0.32) and Sr 2 Ir 1–x Co x O 4 (0 ≤ x < 0.22). Fe doping retains the antiferromagnetic state but simultaneously precipitates an emergent metallic state whereas Co doping causes a rapid collapse of both the antiferromagnetic and Mott states, giving rise to a confined metallic state featuring a pronounced linearity of the basal-plane resistivity up to 700 K. The results indicate tetravalent Fe 4+ (3d 4 ) ions in the intermediate spin state with S = 1 and Co 4+ (3d 5 ) ions in the high spin state with S = 5/2 substituting for Ir 4+ (5d 5 ) ions in Sr 2 IrO 4 , respectively. The effective magnetic moment closely tracks the Néel temperature as doping increases, suggesting that the spin state of the dopant predominately determines the magnetic properties in doped Sr 2 IrO 4 . Furthermore, all relevant properties including charge-carrier density (e.g., 10 28 /m 3 ), Sommerfeld coefficient (e.g., 19 mJ / mole K 2 ), and Wilson ratio (e.g., 2.6) consistently demonstrate an emergent metallic state that is both robust and highly correlated in the two systems, arising from the percolation of bound states and the weakening of structural distortions. Furthermore, this study strongly indicates that the antiferromagnetic and Mott states are correlated in an unconventional manner in Sr 2 IrO 4 .

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

MO-B-BRB-00: Three Dimensional Dosimetry

Full three-dimensional (3D) dosimetry using volumetric chemical dosimeters probed by 3D imaging systems has long been a promising technique for the radiation therapy clinic, since it provides a unique methodology for dose measurements in the volume irradiated using complex conformal delivery techniques such as IMRT and VMAT. To date true 3D dosimetry is still not widely practiced in the community; it has been confined to centres of specialized expertise especially for quality assurance or commissioning roles where other dosimetry techniques are difficult to implement. The potential for improved clinical applicability has been advanced considerably in the last decade by the development of improved 3D dosimeters (e.g., radiochromic plastics, radiochromic gel dosimeters and normoxic polymer gel systems) and by improved readout protocols using optical computed tomography or magnetic resonance imaging. In this session, established users of some current 3D chemical dosimeters will briefly review the current status of 3D dosimetry, describe several dosimeters and their appropriate imaging for dose readout, present workflow procedures required for good dosimetry, and analyze some limitations for applications in select settings. We will review the application of 3D dosimetry to various clinical situations describing how 3D approaches can complement other dose delivery validation approaches already available in the clinic. The applications presented will be selected to inform attendees of the unique features provided by full 3D techniques. Learning Objectives: L. John Schreiner: Background and Motivation Understand recent developments enabling clinically practical 3D dosimetry, Appreciate 3D dosimetry workflow and dosimetry procedures, and Observe select examples from the clinic. Sofie Ceberg: Application to dynamic radiotherapy Observe full dosimetry under dynamic radiotherapy during respiratory motion, and Understand how the measurement of high resolution dose data in an irradiated volume can help understand interplay effects during TomoTherapy or VMAT. Titania Juang: Special techniques in the clinic and research Understand the potential for 3D dosimetry in validating dose accumulation in deformable systems, and Observe the benefits of high resolution measurements for precision therapy in SRS and in MicroSBRT for small animal irradiators Geoffrey S. Ibbott: 3D Dosimetry in end-to-end dosimetry QA Understand the potential for 3D dosimetry for end-to-end radiation therapy process validation in the in-house and external credentialing setting. Canadian Institutes of Health Research; L. Schreiner, Modus QA, London, ON, Canada; T. Juang, NIH R01CA100835.

60 APPLIED LIFE SCIENCES↗

MO-B-BRB-01: 3D Dosimetry in the Clinic: Background and Motivation

Full three-dimensional (3D) dosimetry using volumetric chemical dosimeters probed by 3D imaging systems has long been a promising technique for the radiation therapy clinic, since it provides a unique methodology for dose measurements in the volume irradiated using complex conformal delivery techniques such as IMRT and VMAT. To date true 3D dosimetry is still not widely practiced in the community; it has been confined to centres of specialized expertise especially for quality assurance or commissioning roles where other dosimetry techniques are difficult to implement. The potential for improved clinical applicability has been advanced considerably in the last decade by the development of improved 3D dosimeters (e.g., radiochromic plastics, radiochromic gel dosimeters and normoxic polymer gel systems) and by improved readout protocols using optical computed tomography or magnetic resonance imaging. In this session, established users of some current 3D chemical dosimeters will briefly review the current status of 3D dosimetry, describe several dosimeters and their appropriate imaging for dose readout, present workflow procedures required for good dosimetry, and analyze some limitations for applications in select settings. We will review the application of 3D dosimetry to various clinical situations describing how 3D approaches can complement other dose delivery validation approaches already available in the clinic. The applications presented will be selected to inform attendees of the unique features provided by full 3D techniques. Learning Objectives: L. John Schreiner: Background and Motivation Understand recent developments enabling clinically practical 3D dosimetry, Appreciate 3D dosimetry workflow and dosimetry procedures, and Observe select examples from the clinic. Sofie Ceberg: Application to dynamic radiotherapy Observe full dosimetry under dynamic radiotherapy during respiratory motion, and Understand how the measurement of high resolution dose data in an irradiated volume can help understand interplay effects during TomoTherapy or VMAT. Titania Juang: Special techniques in the clinic and research Understand the potential for 3D dosimetry in validating dose accumulation in deformable systems, and Observe the benefits of high resolution measurements for precision therapy in SRS and in MicroSBRT for small animal irradiators Geoffrey S. Ibbott: 3D Dosimetry in end-to-end dosimetry QA Understand the potential for 3D dosimetry for end-to-end radiation therapy process validation in the in-house and external credentialing setting. Canadian Institutes of Health Research; L. Schreiner, Modus QA, London, ON, Canada; T. Juang, NIH R01CA100835.

60 APPLIED LIFE SCIENCES↗

MO-B-BRB-02: 3D Dosimetry in the Clinic: IMRT Technique Validation in Sweden

Full three-dimensional (3D) dosimetry using volumetric chemical dosimeters probed by 3D imaging systems has long been a promising technique for the radiation therapy clinic, since it provides a unique methodology for dose measurements in the volume irradiated using complex conformal delivery techniques such as IMRT and VMAT. To date true 3D dosimetry is still not widely practiced in the community; it has been confined to centres of specialized expertise especially for quality assurance or commissioning roles where other dosimetry techniques are difficult to implement. The potential for improved clinical applicability has been advanced considerably in the last decade by the development of improved 3D dosimeters (e.g., radiochromic plastics, radiochromic gel dosimeters and normoxic polymer gel systems) and by improved readout protocols using optical computed tomography or magnetic resonance imaging. In this session, established users of some current 3D chemical dosimeters will briefly review the current status of 3D dosimetry, describe several dosimeters and their appropriate imaging for dose readout, present workflow procedures required for good dosimetry, and analyze some limitations for applications in select settings. We will review the application of 3D dosimetry to various clinical situations describing how 3D approaches can complement other dose delivery validation approaches already available in the clinic. The applications presented will be selected to inform attendees of the unique features provided by full 3D techniques. Learning Objectives: L. John Schreiner: Background and Motivation Understand recent developments enabling clinically practical 3D dosimetry, Appreciate 3D dosimetry workflow and dosimetry procedures, and Observe select examples from the clinic. Sofie Ceberg: Application to dynamic radiotherapy Observe full dosimetry under dynamic radiotherapy during respiratory motion, and Understand how the measurement of high resolution dose data in an irradiated volume can help understand interplay effects during TomoTherapy or VMAT. Titania Juang: Special techniques in the clinic and research Understand the potential for 3D dosimetry in validating dose accumulation in deformable systems, and Observe the benefits of high resolution measurements for precision therapy in SRS and in MicroSBRT for small animal irradiators Geoffrey S. Ibbott: 3D Dosimetry in end-to-end dosimetry QA Understand the potential for 3D dosimetry for end-to-end radiation therapy process validation in the in-house and external credentialing setting. Canadian Institutes of Health Research; L. Schreiner, Modus QA, London, ON, Canada; T. Juang, NIH R01CA100835.

60 APPLIED LIFE SCIENCES↗

MO-B-BRB-03: 3D Dosimetry in the Clinic: Validating Special Techniques

Full three-dimensional (3D) dosimetry using volumetric chemical dosimeters probed by 3D imaging systems has long been a promising technique for the radiation therapy clinic, since it provides a unique methodology for dose measurements in the volume irradiated using complex conformal delivery techniques such as IMRT and VMAT. To date true 3D dosimetry is still not widely practiced in the community; it has been confined to centres of specialized expertise especially for quality assurance or commissioning roles where other dosimetry techniques are difficult to implement. The potential for improved clinical applicability has been advanced considerably in the last decade by the development of improved 3D dosimeters (e.g., radiochromic plastics, radiochromic gel dosimeters and normoxic polymer gel systems) and by improved readout protocols using optical computed tomography or magnetic resonance imaging. In this session, established users of some current 3D chemical dosimeters will briefly review the current status of 3D dosimetry, describe several dosimeters and their appropriate imaging for dose readout, present workflow procedures required for good dosimetry, and analyze some limitations for applications in select settings. We will review the application of 3D dosimetry to various clinical situations describing how 3D approaches can complement other dose delivery validation approaches already available in the clinic. The applications presented will be selected to inform attendees of the unique features provided by full 3D techniques. Learning Objectives: L. John Schreiner: Background and Motivation Understand recent developments enabling clinically practical 3D dosimetry, Appreciate 3D dosimetry workflow and dosimetry procedures, and Observe select examples from the clinic. Sofie Ceberg: Application to dynamic radiotherapy Observe full dosimetry under dynamic radiotherapy during respiratory motion, and Understand how the measurement of high resolution dose data in an irradiated volume can help understand interplay effects during TomoTherapy or VMAT. Titania Juang: Special techniques in the clinic and research Understand the potential for 3D dosimetry in validating dose accumulation in deformable systems, and Observe the benefits of high resolution measurements for precision therapy in SRS and in MicroSBRT for small animal irradiators Geoffrey S. Ibbott: 3D Dosimetry in end-to-end dosimetry QA Understand the potential for 3D dosimetry for end-to-end radiation therapy process validation in the in-house and external credentialing setting. Canadian Institutes of Health Research; L. Schreiner, Modus QA, London, ON, Canada; T. Juang, NIH R01CA100835.

60 APPLIED LIFE SCIENCES↗

MO-B-BRB-04: 3D Dosimetry in End-To-End Dosimetry QA

Full three-dimensional (3D) dosimetry using volumetric chemical dosimeters probed by 3D imaging systems has long been a promising technique for the radiation therapy clinic, since it provides a unique methodology for dose measurements in the volume irradiated using complex conformal delivery techniques such as IMRT and VMAT. To date true 3D dosimetry is still not widely practiced in the community; it has been confined to centres of specialized expertise especially for quality assurance or commissioning roles where other dosimetry techniques are difficult to implement. The potential for improved clinical applicability has been advanced considerably in the last decade by the development of improved 3D dosimeters (e.g., radiochromic plastics, radiochromic gel dosimeters and normoxic polymer gel systems) and by improved readout protocols using optical computed tomography or magnetic resonance imaging. In this session, established users of some current 3D chemical dosimeters will briefly review the current status of 3D dosimetry, describe several dosimeters and their appropriate imaging for dose readout, present workflow procedures required for good dosimetry, and analyze some limitations for applications in select settings. We will review the application of 3D dosimetry to various clinical situations describing how 3D approaches can complement other dose delivery validation approaches already available in the clinic. The applications presented will be selected to inform attendees of the unique features provided by full 3D techniques. Learning Objectives: L. John Schreiner: Background and Motivation Understand recent developments enabling clinically practical 3D dosimetry, Appreciate 3D dosimetry workflow and dosimetry procedures, and Observe select examples from the clinic. Sofie Ceberg: Application to dynamic radiotherapy Observe full dosimetry under dynamic radiotherapy during respiratory motion, and Understand how the measurement of high resolution dose data in an irradiated volume can help understand interplay effects during TomoTherapy or VMAT. Titania Juang: Special techniques in the clinic and research Understand the potential for 3D dosimetry in validating dose accumulation in deformable systems, and Observe the benefits of high resolution measurements for precision therapy in SRS and in MicroSBRT for small animal irradiators Geoffrey S. Ibbott: 3D Dosimetry in end-to-end dosimetry QA Understand the potential for 3D dosimetry for end-to-end radiation therapy process validation in the in-house and external credentialing setting. Canadian Institutes of Health Research; L. Schreiner, Modus QA, London, ON, Canada; T. Juang, NIH R01CA100835.

60 APPLIED LIFE SCIENCES↗

High Momentum Transfer Nucleon Elastic Electromagnetic Form Factor Measurements Using Super BigBite Spectrometer at Jefferson Lab

The nucleons - protons and neutrons - are the basic building blocks of atomic nuclei. We now know that the nucleon consists of fundamental particles called quarks and gluons. The quarks interact with each other by exchanging gluons via the strong interaction. Understanding the quark-gluon structure of the nucleon, especially the confinement of quarks within the nucleon in its ground state, remains one of the main unsolved puzzles of particle physics. The nucleon electromagnetic form factors are directly related to the internal structure of the nucleon. A new generation of high precision experiments, GEp-V, GEn-II, GEn-RP, and GMn, measuring the ground state nucleon space-like electro-magnetic form factor at high momentum transfer is underway at Jefferson Lab experimental Hall-A as part of the Super Bigbite Spectrometer (SBS) program. This series of experiments will provide a new level of understanding of the nucleon structure. These experiments are highly demanding due to the extremely fast drop off of the elastic cross section with the increasing four-momentum transfer squared(Q2). This thesis provides an overview of the SBS physics program and reports on the extensive R&D program carried out to achieve the high rate running conditions essential for carrying out the SBS experiments. SBS will provide an intermediate solid angle of approximately 35 msr, which is significantly larger than the solid angle of other dipole based spectrometers at Jefferson lab. Of course, there are much larger acceptance spectrometers at Jefferson Lab, CLAS12 for example. What is special about SBS is that it provides a sizable acceptance while operating at the highest possible luminosity at Jefferson Lab. With this combination of medium acceptance and the highest available luminosity, SBS provides an unparalleled opportunity to explore the nucleon in its ground state with unprecedented resolution. The relatively large acceptance of SBS is achieved by using a large gap dipole magnet and placing it close to the target. An unavoidable consequence of this is that the SBS GEM trackers and other detectors have a clear line-of-sight view of the target and a portion of the beam-line. As a result, the background hit rate in the SBS front GEM trackers is expected to be up to 500 kHz/cm2, over the entire active area of 6000 cm2. To the best of our knowledge, this extremely high rate over such a large area is unprecedented in any particle tracking system used anywhere in the world before. Correctly reconstructing the particle tracks of interest in this very high background environment is achieved by using especially adapted high rate techniques at every step of the tracking process: optimizing the GEM module and tracker design at the hardware level, using high bandwidth electronics and real time Field Programmable Gate Array (FPGA) based background suppression techniques at the Data Acquisition (DAQ) level, and developing highly specialized tracking algorithms to pick out the signal hits from among the vast amount of background hits. In order to ensure a smooth start and running of the SBS experiments, it is extremely crucial that these techniques are developed, implemented, and tested under realistic conditions well before the actual start of the SBS experimental program. A detailed Geant4 simulation of the experiment was combined with a digitization package to generate the detector level pseudodata similar to what is expected in the actual experiments. The digitization procedures were calibrated against actual GEM data from cosmic-ray runs, X-ray tests, beam test runs in experimental Hall-A, and the PRad experiment in Hall B. Then, optimized tracking algorithms were developed and implemented in an analysis program used to analyze these pseudo-data and to extract expected high-level parameters. These extracted quantities were then compared with the input parameters from the simulation to verify and determine the performance characteristics for the SBS tracker. From this work, a final tracking efficiency of 69% at 25% occupancy was achieved, with the required reconstruction accuracy, for the GMn experiment, the first experiment in the SBS program, with background level at 100 kHz/cm2. These demonstrated parameters are adequate for the successful running of not only the GMn experiment but as well as for GEn-RP and GEn-II experiments, the second and third experiments in the program. This work builds the solid ground to further improve the tracking performance for these experiments and achieve similar conditions for the running of the GEp-V experiment, the most demanding experiment in the SBS program, with an expected background level at 500 kHz/cm2.

Di, Danning↗

Optical Activity of Chiral Excitons

Recent activity in the area of chiroptical phenomena has been focused on the connection between structural asymmetry, electron spin configuration and light/matter interactions in chiral semiconductors. In these systems, spin‐splitting phenomena emerge due to inversion symmetry breaking and the presence of extended electronic states, yet the connection to chiroptical phenomena is lacking. Here, in this study, we develop an analytical effective mass model of chiral excitons, parameterized by density functional theory. The model accounts for parity mixing of the band edge Bloch functions resulting from polar distortions, resulting in allowed magnetic dipole transitions. Through the study of a prototypical chiral 2D hybrid perovskite semiconductor, we show that circular dichroism of the chiral exciton and its interband continuum emerges from spin‐splitting via cross‐coupling of Rashba‐like and chiral/helical spin‐texture components. To demonstrate the generality of our approach, and as a counterpoint, we apply our model to describe chiroptical properties of three‐dimensionally confined excitons in perovskite nanocrystals that occur without chiral lattice distortions.

14 SOLAR ENERGY↗

Hessian matrix approach for determining error field sensitivity to coil deviations.

The presence of error fields has been shown to degrade plasma confinement and drive instabilities. Error fields can arise from many sources, but are predominantly attributed to deviations in the coil geometry. In this paper, we introduce a Hessian matrix approach for determining error field sensitivity to coil deviations. A primary cost function used for designing stellarator coils, the surface integral of normalized normal field errors, was adopted to evaluate the deviation of the generated magnetic field from the desired magnetic field. The FOCUS code [Zhu et al., Nucl. Fusion 58(1):016008 (2018)] is utilized to provide fast and accurate calculations of the Hessian. The sensitivities of error fields to coil displacements are then determined by the eigenvalues of the Hessian matrix. A proof-of-principle example is given on a CNT-like configuration. We anticipate that this new method could provide information to avoid dominant coil misalignments and simplify coil designs for stellarators.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of high-performance long-pulse discharge in KSTAR

High-performance long-pulse plasma operation is essential for producing economically viable fusion energy in tokamak devices. To achieve such discharges in KSTAR, firstly, the rapid increase in the temperature of plasma-facing components was mitigated. The temperature increase of the poloidal limiter, especially, was associated with beam-driven fast ion orbit loss and the discrepancy of the equilibrium reconstructed with heated magnetic probes of signal drift. The fast ions lost to the poloidal limiter were reduced by optimizing the plasma shape and the composition of neutral beam injection (NBI). This nonlinear signal drift was successfully reduced by a new thermal shielding protector on the magnetic probes. Secondly, a lower loop voltage approach was implemented to reduce a poloidal flux consumption rate. A plasma current of 400 kA and a line-averaged electron density of ~2.0 × 10 19 m –3 were chosen by considering the L–H power threshold, fast ion orbit loss, and beam shine-through power loss for low loop voltage in KSTAR. In addition, the application of electron cyclotron heating also helped maintain the plasma with low loop voltage (~25 mV) by enhancing the NBI-driven current and achieving a high poloidal beta (β P ) state. KSTAR has achieved a long pulse (~90 s) operation with the high performance of β P $\leqslant$ 2.7, thermal energy confinement enhancement factor (H 98y2 ) ~ 1.1, and fraction of non-inductive current (f NI ) $\leqslant$ 0.96. Still, gradual degradation of the plasma performance has been observed over time in the discharges. In one of the long-pulse discharges, β P reduced by ~18% over the time of ~8τ R (current relaxation time, τ R ~5 s) and ~1067τ E,th (thermal energy confinement time, τ E,th ~45 ms). The degradation may be closely associated with weak, yet growing, and persistent toroidal Alfvén eigenmodes and their effect on fast ion confinement.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Data-driven model for divertor plasma detachment prediction

We present a fast and accurate data-driven surrogate model for divertor plasma detachment prediction leveraging the latent feature space concept in machine learning research. Our approach involves constructing and training two neural networks: an autoencoder that finds a proper latent space representation (LSR) of plasma state by compressing the multi-modal diagnostic measurements and a forward model using multi-layer perception (MLP) that projects a set of plasma control parameters to its corresponding LSR. By combining the forward model and the decoder network from autoencoder, this new data-driven surrogate model is able to predict a consistent set of diagnostic measurements based on a few plasma control parameters. In order to ensure that the crucial detachment physics is correctly captured, highly efficient 1D UEDGE model is used to generate training and validation data in this study. The benchmark between the data-driven surrogate model and UEDGE simulations shows that our surrogate model is capable of providing accurate detachment prediction (usually within a few per cent relative error margin) but with at least four orders of magnitude speed-up, indicating that performance-wise, it has the potential to facilitate integrated tokamak design and plasma control. Comparing with the widely used two-point model and/or two-point model formatting, the new data-driven model features additional detachment front prediction and can be easily extended to incorporate richer physics. This study demonstrates that the complicated divertor and scrape-off-layer plasma state has a low-dimensional representation in latent space. Understanding plasma dynamics in latent space and utilising this knowledge could open a new path for plasma control in magnetic fusion energy research.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Quantitative 3D electromagnetic field determination of 1D nanostructures from single projection

One-dimensional (1D) nanostructures have been regarded as the most promising building blocks for nanoelectronics and nanocomposite material systems as well as for alternative energy applications. Although they result in confinement of a material, their properties and interactions with other nanostructures are still very much three-dimensional (3D) in nature. In this work, we present a novel method for quantitative determination of the 3D electromagnetic fields in and around 1D nanostructures using a single electron wave phase image, thereby eliminating the cumbersome acquisition of tomographic data. Using symmetry arguments, we have reconstructed the 3D magnetic field of a nickel nanowire as well as the 3D electric field around a carbon nanotube field emitter, from one single projection. The accuracy of quantitative values determined here is shown to be a better fit to the physics at play than the value obtained by conventional analysis. Moreover the 3D reconstructions can then directly be visualized and used in the design of functional 3D architectures built using 1D nanostructures.

1D nanostructures↗

Study on structural, optical properties of solvothermally synthesized Ni doped CdS nanorods

Undoped and alkali metal i.e Ni doped CdS nanorods (Cd{sub x}Ni{sub 1-x}S) with (x = 0.0, 0.3,) has been synthesized by using a convenient solvothermal technique. In order to confirm the structure of the synthesized nanorods X-ray diffraction (XRD) has been done which reveals the formation of hexagonal phase of the dilute magnetic semiconducting nanorods having size of undoped 27.79nm and doped 17.49nm. Energy dispersive X-ray analysis depicts the presence of elements Cd, Ni and S in their stoichiometric ratio. Optical behavior of undoped and doped nanorods has been investigated. UV-visible spectra show the blue shift in the band gap, as compared to the bulk CdS which may be due the quantum confinement occurs in the nanostructures. Morphological analysis has been done with the help of Transmission electron microscope which confirms the polycrystalline nature of the synthesized nanorods.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Impact of toroidal magnetic field direction on integrated ELM-stable operation and divertor power exhaust via boron powder injection in EAST

We report the first in-depth comparison of the impact of toroidal magnetic field direction on solid boron injection used for Edge-Localized Mode (ELM) control, power exhaust, and core high-Z impurity control in the Experimental Advanced Superconducting Tokamak. With favorable ion ∇B drift towards the upper X-point in an upper-single-null configuration, boron injection effectively suppresses ELMs, produces a detachment of the inner divertor target, and leads to improved energy confinement. ELM suppression in this configuration is accompanied by the excitation of an Edge Harmonic Mode. In contrast, with unfavorable ion ∇B drift away from the upper X-point, boron injection also suppresses ELMs but leads to a more symmetric detachment state of both the inner and outer divertor targets, while plasma energy confinement is slightly degraded despite similar boron injection levels; a different low-frequency coherent mode without multiple harmonics is observed. Measurements from toroidally separated views show that the divertor response to boron injection is essentially toroidally symmetric, supporting the use of two-dimensional SOLPS-ITER modeling with a toroidally uniform impurity source. These experimental observations are qualitatively consistent with SOLPS-ITER simulations, which highlight the critical role of E × B drift effects in setting the Bt-dependent in–out asymmetry of detachment and in asymmetrically transporting particles and injected impurities within the scrape-off layer and private-flux region. These findings underscore the importance of drift physics and real-time wall conditioning in controlling low-Z impurity transport and optimizing edge solutions for integrated, ELM-stable, high-performance tokamak operation.

E × B drift↗