A magnetically shielded room with ultra low residual field and gradient

A versatile and portable magnetically shielded room with a field of (700 ± 200) pT within a central volume of 1 m × 1 m × 1 m and a field gradient less than 300 pT/m, achieved without any external field stabilization or compensation, is described. This performance represents more than a hundredfold improvement of the state of the art for a two-layer magnetic shield and provides an environment suitable for a next generation of precision experiments in fundamental physics at low energies; in particular, searches for electric dipole moments of fundamental systems and tests of Lorentz-invariance based on spin-precession experiments. Studies of the residual fields and their sources enable improved design of future ultra-low gradient environments and experimental apparatus. This has implications for developments of magnetometry beyond the femto-Tesla scale in, for example, biomagnetism, geosciences, and security applications and in general low-field nuclear magnetic resonance (NMR) measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electric field stimulation setup for photoemission electron microscopes

Manipulating magnetisation by the application of an electric field in magnetoelectric multiferroics represents a timely issue due to the potential applications in low power electronics and the novel physics involved. Thanks to its element sensitivity and high spatial resolution, X-ray photoemission electron microscopy is a uniquely suited technique for the investigation of magnetoelectric coupling in multiferroic materials. In this work, we present a setup that allows for the application of in situ electric and magnetic fields while the sample is analysed in the microscope. As an example of the performances of the setup, we present measurements on Ni/Pb(Mg{sub 0.66}Nb{sub 0.33})O{sub 3}-PbTiO{sub 3} and La{sub 0.7}Sr{sub 0.3}MnO{sub 3}/PMN-PT artificial multiferroic nanostructures.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Microcalorimeter measurement of x-ray spectra from a high-temperature magnetically confined plasma

A NASA-built x-ray microcalorimeter spectrometer has been installed on the MST facility at the Wisconsin Plasma Physics Laboratory and has recorded x-ray photons emitted by impurity ions of aluminum in a majority deuterium plasma. Much of the x-ray microcalorimeter development has been driven by the needs of astrophysics missions, where imaging arrays with few-eV spectral resolution are required. The goal of our project is to adapt these single-photon-counting microcalorimeters for magnetic fusion energy research and demonstrate the value of such measurements for fusion science. Microcalorimeter spectrometers combine the best characteristics of the x-ray instrumentation currently available on fusion devices: high spectral resolution similar to an x-ray crystal spectrometer and the broadband coverage of an x-ray pulse height analysis system. Fusion experiments are increasingly employing high-Z plasma-facing components and require measurement of the concentration of all impurity ion species in the plasma. This diagnostic has the capability to satisfy this need for multi-species impurity ion data and will also contribute to measurements of impurity ion temperature and flow velocity, Zeff, and electron density. Here, we introduce x-ray microcalorimeter detectors and discuss the diagnostic capability for magnetic fusion energy experiments. We describe our experimental setup and spectrometer operation approach at MST, and we present the results from an initial measurement campaign.

Eckart, M. E. (ORCID:0000000338945889)↗

First Observations from the SPICE EUV Spectrometer on Solar Orbiter

Aims. We present first science observations taken during the commissioning activities of the Spectral Imaging of the Coronal Environment (SPICE) instrument on the ESA/NASA Solar Orbiter mission. SPICE is a high-resolution imaging spectrometer operating at extreme ultraviolet (EUV) wavelengths. In this paper we illustrate the possible types of observations to give prospective users a better understanding of the science capabilities of SPICE. Methods. We have reviewed the data obtained by SPICE between April and June 2020 and selected representative results obtained with different slits and a range of exposure times between 5 s and 180 s. Standard instrumental corrections have been applied to the raw data. Results. The paper discusses the first observations of the Sun on different targets and presents an example of the full spectra from the quiet Sun, identifying over 40 spectral lines from neutral hydrogen and ions of carbon, oxygen, nitrogen, neon, sulphur, magnesium, and iron. These lines cover the temperature range between 20,000 K and 1 million K (10MK in flares), providing slices of the Sun’s atmosphere in narrow temperature intervals. We provide a list of count rates for the 23 brightest spectral lines. We show examples of raster images of the quiet Sun in several strong transition region lines, where we have found unusually bright, compact structures in the quiet Sun network, with extreme intensities up to 25 times greater than the average intensity across the image. The lifetimes of these structures can exceed 2.5 hours. We identify them as a transition region signature of coronal bright points and compare their areas and intensity enhancements. We also show the first above-limb measurements with SPICE above the polar limb in C III,O VI, and Ne VIII lines, and far off limb measurements in the equatorial plane in Mg IX, Ne VIII, and O VI lines. We discuss the potential to use abundance diagnostics methods to study the variability of the elemental composition that can be compared with in situ measurements to help confirm the magnetic connection between the spacecraft location and the Sun’s surface, and locate the sources of the solar wind. Conclusions. The SPICE instrument successfully performs measurements of EUV spectra and raster images that will make vital contributions to the scientific success of the Solar Orbiter mission

Sun: UV radiation↗

Neutron intensity modulation and time-focusing with integrated Larmor and resonant frequency techniques

The analysis of neutron diffraction experiments often assumes that neutrons are elastically scattered from the sample. However, there is growing evidence that a significant fraction of the detected neutrons is in fact inelastically scattered, especially from soft materials and aqueous samples. Ignoring these inelastic contributions gives rise to inaccurate experimental results. To date, there has been no simple method with broad applicability for inelastic signal separation in neutron diffraction experiments. Here, we present a simple and robust method that we believe could be suited for this purpose. We use two radio frequency resonant spin flippers integrated with a Larmor precession field to modulate the neutron intensity and to encode the inelastic scattering information into the neutron data. All three components contribute to the spin encoding. The Larmor field serves several additional purposes. Its usage facilitates neutron time-focusing, eliminates the need for stringent magnetic shielding, and allows for compact setups. The scheme is robust, simple, and flexible. We believe that, with further improvements, it has the potential of adding inelastic signal discrimination capabilities to many existing diffraction instruments in the future.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Parametric design of tri-axial nested Helmholtz coils

This paper provides an optimal parametric design for tri-axial nested Helmholtz coils, which are used to generate a uniform magnetic field with controllable magnitude and direction. Circular and square coils, both with square cross section, are considered. Practical considerations such as wire selection, wire-wrapping efficiency, wire bending radius, choice of power supply, and inductance and time response are included. Using the equations provided, a designer can quickly create an optimal set of custom coils to generate a specified field magnitude in the uniform-field region while maintaining specified accessibility to the central workspace. An example case study is included.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Note: Fiber optic transport probe for Hall measurements under light and magnetic field at low temperatures: Case study of a two dimensional electron gas

A fiber optic based probe is designed and developed for electrical transport measurements in presence of quasi-monochromatic (360–800 nm) light, varying temperature (T = 1.8–300 K), and magnetic field (B = 0–7 T). The probe is tested for the resistivity and Hall measurements performed on a LaAlO{sub 3}–SrTiO{sub 3} heterointerface system with a conducting two dimensional electron gas.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Gas Gun-Configured Magnetic Flux Compression Generator, NLV-013-17, Year 1 of 3

Presentation on project to explore the concept of achieving current amplification by principles of high-explosive magnetic compression generation but without high explosives and demonstrate that a gas gun or launcher could be configured to provide the input energy and action necessary for magnetic compression generation performance in a more controlled, cost-effective manner with improved safety.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The characteristic of evaporative cooling magnet for ECRIS

Compared with traditional de-ionized pressurized-water cooled magnet of ECRIS, evaporative cooling magnet has some special characteristics, such as high cooling efficiency, simple maintenance, and operation. The analysis is carried out according to the design and operation of LECR4 (Lanzhou Electron Cyclotron Resonance ion source No. 4, since July 2013), whose magnet is cooled by evaporative cooling technology. The insulation coolant replaces the de-ionized pressurized-water to absorb the heat of coils, and the physical and chemical properties of coolant remain stable for a long time with no need for purification or filtration. The coils of magnet are immersed in the liquid coolant. For the higher cooling efficiency of coolant, the current density of coils can be greatly improved. The heat transfer process executes under atmospheric pressure, and the temperature of coils is lower than 70 °C when the current density of coils is 12 A/mm{sup 2}. On the other hand, the heat transfer temperature of coolant is about 50 °C, and the heat can be transferred to fresh air which can save cost of water cooling system. Two years of LECR4 stable operation show that evaporative cooling technology can be used on magnet of ECRIS, and the application advantages are very obvious.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Magnetostrictive Ultrasonic Waveguide Transducer for In-Pile Thermometry

Real-time and reliable temperature measurement on nuclear fuels is crucial for the safe operation of existing pressurized-water reactors and future advanced nuclear reactors. Magnetostrictive materials deform when subjected to a magnetic field or exhibit magnetization variation when stressed. Here, based on these properties, this study prototyped an ultrasonic thermometer (UT) consisting of a magnetostrictive waveguide, a dc coil providing appropriate magnetic biasing, and an ac coil generating an acoustic impulse and detecting the resulting acoustic echoes. By tracking the time of flight between the excitation pulse and the echoes, the UT can potentially detect nuclear fuel cladding temperature from a long distance. In this study, magnetostrictive iron–gallium alloys, or Galfenol, were selected as the waveguide due to their large magnetostriction, superior temperature survivability, excellent radiation resilience, and high mechanical robustness. A multiphysics finite-element model considering electrical, magnetic, and mechanical dynamics in the magnetostrictive UT was then developed. The model exhibited an error of 0.24% in time-of-flight simulation and, therefore, enabled computer-aided design and guided signal processing. Between room temperature and 120 °C, the new Galfenol-based UT exhibits a linear sensitivity of 162.8×10 ₋6 °C ₋1 , which is 51.7% higher than a previous magnetostrictive UT based on iron–cobalt–vanadium alloys.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

On the analysis of inhomogeneous magnetic field spectrometer for laser-driven ion acceleration

We present a detailed study of the use of a non-parallel, inhomogeneous magnetic field spectrometer for the investigation of laser-accelerated ion beams. Employing a wedged yoke design, we demonstrate the feasibility of an in-situ self-calibration technique of the non-uniform magnetic field and show that high-precision measurements of ion energies are possible in a wide-angle configuration. We also discuss the implications of a stacked detector system for unambiguous identification of different ion species present in the ion beam and explore the feasibility of detection of high energy particles beyond 100 MeV/amu in radiation harsh environments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

THE GALACTIC PLANE INFRARED POLARIZATION SURVEY (GPIPS): DATA RELEASE 1

The Galactic Plane Infrared Polarization Survey (GPIPS) covers 76 deg{sup 2} of the first Galactic quadrant midplane, 18 Degree-Sign {<=} l {<=} 56 Degree-Sign and -1 Degree-Sign {<=} b {<=} +1 Degree-Sign , in H-band (1.6 {mu}m) linear polarimetry to reveal the plane-of-the-sky orientation of the magnetic field in diffuse and denser atomic and molecular clouds. The Survey consists of 3237 overlapping 10 Multiplication-Sign 10 arcmin fields observed using the Mimir instrument on the 1.8 m Perkins telescope. Here, the first community release of GPIPS data for 559 fields (17% of the Survey) is announced and basic characteristics are described. Data products consist of H-band stellar photometry and polarimetry as well as combined images. The formats and contents of the products are described and quality cuts are explored to provide insight into opportunities and limitations of the data. The Survey probes to distances as far as the Galactic bulge, revealing magnetic field properties that correlate with spiral arms and also show significant small-scale structure. The polarizations are classified into three 'usage' samples, based on stellar brightness and polarimetric uncertainty. The brightest, lowest uncertainty polarizations are suitable for individual use and direct magnetic field mapping. The next two fainter samples are useful, once averaged, for probing magnetic fields to greater distances, albeit with lower resolution. Based on this release, the full GPIPS data set will number about 5.6 million stars, with more than 1 million in the high-quality sample. This increases, by many orders of magnitude, the number of polarimetric probes of the Milky Way's magnetic field.

79 ASTRONOMY AND ASTROPHYSICS↗

The Polar Plasma Wave Instrument

The Plasma Wave Instrument on the Polar spacecraft is designed to provide measurements of plasma waves in the Earth's polar regions over the frequency range from 0.1 Hz to 800 kHz. Three orthogonal electric dipole antennas are used to detect electric fields, two in the spin plane and one aligned along the spacecraft spin axis. A magnetic loop antenna and a triaxial magnetic search coil antenna are used to detect magnetic fields. Signals from these antennas are processed by five receiver systems: a wideband receiver, a high-frequency waveform receiver, a low-frequency waveform receiver, two multichannel analyzers; and a pair of sweep frequency receivers. Compared to previous plasma wave instruments, the Polar plasma wave instrument has several new capabilities. These include (1) an expanded frequency range to improve coverage of both low- and high-frequency wave phenomena, (2) the ability to simultaneously capture signals from six orthogonal electric and magnetic field sensors, and (3) a digital wideband receiver with up to 8-bit resolution and sample rates as high as 249k samples s(exp -1).

Gurnett, D. A.↗

The mineralogy of global magnetic anomalies

The Curie Balance was brought to operational stage and is producing data of a preliminary nature. Substantial problems experienced in the assembly and initial operation of the instrument were, for the most part, rectified, but certain problems still exist. Relationships between the geology and the gravity and MAGSAT anomalies of West Africa are reexamined in the context of a partial reconstruction of Gondwanaland.

Haggerty, S. E.↗

A 31 T split-pair pulsed magnet for single crystal x-ray diffraction at low temperature

We have developed a pulsed magnet system with panoramic access for synchrotron x-ray diffraction in magnetic fields up to 31 T and at low temperature down to 1.5 K. The apparatus consists of a split-pair magnet, a liquid nitrogen bath to cool the pulsed coil, and a helium cryostat allowing sample temperatures from 1.5 up to 250 K. Using a 1.15 MJ mobile generator, magnetic field pulses of 60 ms length were generated in the magnet, with a rise time of 16.5 ms and a repetition rate of 2 pulses/h at 31 T. The setup was validated for single crystal diffraction on the ESRF beamline ID06.

43 PARTICLE ACCELERATORS↗

Modeling magnetic fields with helical solutions to Laplace’s equation

The series solution to Laplace's equation in a helical coordinate system is derived and refined using symmetry and chirality arguments. These functions and their more commonplace counterparts are used to model solenoidal magnetic fields via linear, multidimensional curve-fitting. A judicious choice of functional forms, a small number of free parameters and sparse input data can lead to highly accurate, fine-grained modeling of solenoidal magnetic fields, including helical features arising from the winding of the solenoid, with overall field accuracy at better than one part per million.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron resonance spin flippers: Static coils manufactured by electrical discharge machining

Radiofrequency spin flippers (RFSF) are key elements of Neutron Resonance Spin Echo (NRSE) spectrometers, which allow performing controlled manipulations of the beam polarization. We report on the design and test of a new type of RFSF which originality lies in the new manufacturing technique for the static coil. The largely automated procedure ensures reproducible construction as well as an excellent homogeneity of the neutron magnetic resonance condition over the coil volume. Two salient features of this concept are the large neutron window and the closure of the coil by a μ-metal yoke which prevents field leakage outside of the coil volume. These properties are essential for working with large beams and enable new applications with coils tilted with respect to the beam axis such as neutron Larmor diffraction or the study of dispersive excitations by inelastic NRSE.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

STANFORD IN-SITU HIGH RATE YBCO PROCESS: TRANSFER TO METAL TAPES AND PROCESS SCALE UP

Executive Summary The materials science understanding of high rate low cost processes for Coated Conductor will benefit the application to power utilities for low loss energy transportation and power generation as well for DOD applications. The research in this program investigated several materials processing approaches that are new and original, and are not being investigated elsewhere. This work added to the understanding of the material science of high rate PVD growth of HTSC YBCO assisted by a liquid phase. A new process discovered uses amorphous glassy precursors which can be made at high rate under flexible conditions of temperature and oxygen, and later brought to conditions of oxygen partial pressure and temperature for rapid conversion to YBCO superconductor. Good critical current densities were found, but further effort is needed to optimize the vortex pinning using known artificial inclusions. A new discovery of the physics and materials science of vortex pinning in the HTSC system using Sm in place of Y came at growth at unusually low oxygen pressure resulting in clusters of a low or non superconducting phase within the nominal high temperature phase. The driving force for this during growth is new physics, perhaps due to the low oxygen. This has the potential for high current in large magnetic fields at low cost, applicable to motors, generators and transformers. The technical demands of this project were the motivation for the development of instrumentation that could be essential to eventual process scale up. These include atomic absorption based on tunable diode lasers for remote monitoring and control of evaporation sources (developed under DARPA support), and the utility of Fourier Transform Infrared Reflectivity (FTIR) for aid in the synthesis of complex thin film materials (purchased by a DURIP-AFOSR grant).

24 POWER TRANSMISSION AND DISTRIBUTION↗