Search NASA⌕ Search

SEARCH · Search NASA

Results for “Optical Probe”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,783 records · Page 99

INFERENCE OF INHOMOGENEOUS CLOUDS IN AN EXOPLANET ATMOSPHERE

We present new visible and infrared observations of the hot Jupiter Kepler-7b to determine its atmospheric properties. Our analysis allows us to (1) refine Kepler-7b's relatively large geometric albedo of Ag = 0.35 ± 0.02, (2) place upper limits on Kepler-7b thermal emission that remains undetected in both Spitzer bandpasses and (3) report a westward shift in the Kepler optical phase curve. We argue that Kepler-7b's visible flux cannot be due to thermal emission or Rayleigh scattering from H{sub 2} molecules. We therefore conclude that high altitude, optically reflective clouds located west from the substellar point are present in its atmosphere. We find that a silicate-based cloud composition is a possible candidate. Kepler-7b exhibits several properties that may make it particularly amenable to cloud formation in its upper atmosphere. These include a hot deep atmosphere that avoids a cloud cold trap, very low surface gravity to suppress cloud sedimentation, and a planetary equilibrium temperature in a range that allows for silicate clouds to potentially form in the visible atmosphere probed by Kepler. Our analysis does not only present evidence of optically thick clouds on Kepler-7b but also yields the first map of clouds in an exoplanet atmosphere.

79 ASTRONOMY AND ASTROPHYSICS↗

Time stamping of single optical photons with 10 ns resolution

High spatial and temporal resolution are key features for many modern applications, e.g. mass spectrometry, probing the structure of materials via neutron scattering, studying molecular structure, etc. Fast imaging also provides the capability of coincidence detection, and the further addition of sensitivity to single optical photons with the capability of timestamping them further broadens the field of potential applications. Here, photon counting is already widely used in X-ray imaging, where the high energy of the photons makes their detection easier.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Extra sub-Doppler lines in the vicinity of the third-resonance 6S-8P transition of atomic Cs attributed to optically induced Cs dimers

We report on the observation of additional sub-Doppler lines in a saturated absorption experiment when exploring the vicinity of the 6S{sub 1/2}-8P{sub 3/2} transition of Cs ({lambda}=388 nm). These additional lines are observed only under a relatively strong irradiation of both the pump and the probe beams. Extra narrow lines are also observed in copropagating nonlinear spectroscopy, and around the lines of the V-type three-level system 8P{sub 3/2}-6S{sub 1/2}-8P{sub 1/2} ({lambda}{sub 1}=388 nm, {lambda}{sub 2}=389 nm). We attribute theses additional lines to a probing of high-lying molecular cesium, produced as a result of the optical excitation of Cs atoms, as the low Cs atom density ({<=}10{sup 12}cm{sup -3}) is unable to populate significantly the dimer states in the condition of thermal equilibrium.

74 ATOMIC AND MOLECULAR PHYSICS↗

Nanoscale probing of resonant photonic modes in dielectric nanoparticles with focused electron beams

We report that understanding the optical responses of nanostructures with high spatial resolution is paramount in photonic engineering. The excitation of resonant optical-frequency geometric modes in oxide nanoparticles is explored using monochromated electron energy-loss spectroscopy in a scanning transmission electron microscope. These geometric or cavity modes are found to produce a progression of resonance peaks within the bandgap regions of the electron energy-loss spectra of CeO 2 , TiO 2 , and MgO nanoparticles. Complementary simulations of the electron probe combined with analytic Mie analysis are performed to interpret the complex spectral features and to understand their underlying physical origins. The factors that influence the energies, shapes, and strengths of these modes are also investigated and their dependence upon nanoparticle size, geometry, refractive index, aggregation, impact parameter, and electron kinetic energy are elucidated. Taken together, this work demonstrates the unique ability of fast electron spectroscopy to determine the photonic density of states in individual and complex assemblies of dielectric nanoparticles.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Hyperbolic enhancement of photocurrent patterns in minimally twisted bilayer graphene

Quasi-periodic moiré patterns and their effect on electronic properties of twisted bilayer graphene have been intensely studied. At small twist angle θ, due to atomic reconstruction, the moiré superlattice morphs into a network of narrow domain walls separating micron-scale AB and BA stacking regions. We use scanning probe photocurrent imaging to resolve nanoscale variations of the Seebeck coefficient occurring at these domain walls. The observed features become enhanced in a range of mid-infrared frequencies where the hexagonal boron nitride substrate is optically hyperbolic. Our results illustrate the capabilities of the nano-photocurrent technique for probing nanoscale electronic inhomogeneities in two-dimensional materials.

42 ENGINEERING↗

The Vector Electric Field Investigation on the C/NOFS Satellite

We provide an overview of the Vector Electric Field Investigation (VEFI) on the Air Force Communication/Navigation Outage Forecasting System (C/NOFS) satellite, a mission designed to understand, model, and forecast the presence of equatorial ionospheric irregularities. VEFI is a NASA/GSFC instrument funded by the Air Force Research Laboratory whose main objectives are to: 1) investigate the role of the ambient electric fields in initiating nighttime ionospheric density depletions and turbulence; 2) determine the quasi-DC electric fields associated with abrupt, large amplitude, density depletions, and 3) quantify the spectrum of the wave electric fields and plasma densities (irregularities) associated with density depletions typically referred to as equatorial spread-F. The VEFI instrument includes a vector electric field double probe detector, a fixed-bias Langmuir probe operating in the ion saturation regime, a flux-gate magnetometer, an optical lightning detector, and associated electronics. The heart of the instrument is the set of detectors designed to measure DC and AC electric fields using 6 identical booms that provide 3 axis, 20-m tip-to-tip orthogonal double probes. Each probe extends a 10 cm diameter sphere containing an embedded preamplifier. VEFI also includes a burst memory that enables snapshots of data from 1-8 channels of selected instruments to be sampled at rates of up to 32 kHz each. The bursts may be triggered by the detection of density depletions, intense electric field wave activity in a given band, lightning detector pulses, or an event at a pre-determined time or location. All VEFI instrument components are working exceptionally well. A description of the instrument, its sensors, and their sampling frequencies and sensitivities will be presented. Representative measurements will be shown.

Pfaff, R.↗

Optical calibration of the SuperCam instrument body unit spectrometers

The SuperCam remote sensing instrument on NASA’s Perseverance rover is capable of four spectroscopic techniques, remote micro-imaging, and audio recording. These analytical techniques provide details of the chemistry and mineralogy of the rocks and soils probed in the Jezero Crater on Mars. Here we present the methods used for optical calibration of the three spectrometers covering the 243–853 nm range used by three of the four spectroscopic techniques. We derive the instrument optical response, which characterizes the instrument sensitivity to incident radiation as a function of a wavelength. The instrument optical response function derived here is an essential step in the interpretation of the spectra returned by SuperCam as it converts the observed spectra, reported by the instrument as “digital counts” from an analog to digital converter, into physical values of spectral radiance.

Legett, Carey (ORCID:0000000247412841)↗

An organic dye with very large Stokes-shift and broad tunability of fluorescence: Potential two-photon probe for bioimaging and ultra-sensitive solid-state gas sensor

Light-emitting nonlinear optical molecules, especially those with large Stokes shifts and broad tunability of their emission wavelength, have attracted considerable attention for various applications including biomedical imaging and fluorescent sensors. However, most fluorescent chromophores have only limited potential for such applications due to small Stokes shifts, narrow tunability of fluorescence emissions, and small optical nonlinearity in highly polar solvents. In this work, we demonstrate that a two-photon absorbing stilbene chromophore exhibits a large two-photon absorption action cross-section (ηδ = 320 GM) in dimethylsulfoxide (DMSO) and shows broad fluorescence tunability (125 nm) by manipulating the polarity of the surrounding medium. Importantly, a very large Stokes shift of up to 227 nm is achieved in DMSO. Thanks to these features, this chromophore can be utilized as a two-photon probe for bioimaging applications and in an ultrasensitive solid-state gas detector.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Low-Frequency Oscillations in Optical Measurements of Metal-Nanoparticle Vibrations

Time-resolved optical measurements of vibrating metal nanoparticles have been used extensively to probe the ultrafast mechanical properties of the nanoparticles and of the surrounding liquid, but nearly all investigations so far have been limited to the linear regime. Herein, we report the observation of a low-frequency oscillating signal in transient-absorption measurements of nanoparticles with octahedral gold cores and cubic silver shells; the signal appears at the difference of two mechanical vibrational frequencies in the particles, suggesting a nonlinear mixing process. We tentatively attribute this proposed mixing to a nonlinear coupling between a vibrational mode of the nanoparticle and its optical-frequency plasmon resonance. The optimization of this nonlinear transduction may enable high-efficiency opto-mechanical frequency mixing in the GHz-THz frequency regime.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Optical absorption induced by small polaron formation in transition metal oxides: The case of Co 3 O 4

Small polarons (SPs) are known to exist in most important transition metal oxides; however, the nature of small polaron formation remains enigmatic, and a fundamental understanding of how SPs impact the intrinsic electronic structure and optical properties of these materials is largely lacking. In this work, we employ first-principles calculations to investigate SP formation in Co 3 O 4 , a highly promising material for a wide range of emerging energy applications, and we resolve the conflicting findings that have been reported on the electronic structure of the system. We confirm that the intrinsic band gap of Co 3 O 4 is 1.6 eV, and we show that the formation of small hole polarons significantly influences the optical absorption spectra, leading to a 0.8 eV transition that is often misinterpreted as the band edge that defines the fundamental gap. In addition, we discuss how uniaxial strain can be utilized to probe the Jahn-Teller distortion of SP states and, in turn, effect their optical transitions. Beyond Co 3 O 4 , our study suggests a general roadmap for establishing a first-principles computational approach that can simultaneously achieve an accurate description of SP states, electronic band structure, and optical transitions of polaronic magnetic oxides.

36 MATERIALS SCIENCE↗

Imaging of the magnetic field structure in megagauss plasmas by combining pulsed polarimetry with an optical Kerr effect shutter technique

Pulsed polarimetry in combination with a high speed photographic technique based on the optical Kerr effect is described. The backscatter in a pulsed polarimeter is directed through a scattering cell and photographed using an {approx}1 ps shutter, essentially freezing the intensity pattern. The image provides both the local electron density and magnetic field distributions along and transverse to the laser sightline. Submillimeter spatial resolution is possible for probing wavelengths in the visible due to the high densities and strong optical activity. Pulsed polarimetry is thereby extended to centimeter-sized plasmas with n{sub e}>10{sup 19}-10{sup 20} cm{sup -3} and B>20-100 T (MG) produced by multiterawatt, multimega-ampere electrical drivers, wire Z pinches, and liner imploded magnetized plasmas.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Proposed measurement of spin currents in a GaAs crystal using the electro-optical Pockels effect

A new method for measuring spin currents is proposed, based on the linear electro-optic (Pockels) effect caused by the additional second-order nonlinear electric susceptibility (electro-optic tensor) generated by the spin currents. The non-zero elements of electro-optic tensor induced by spin currents in GaAs crystal are calculated, and the wave coupling theory of linear electro-optic effect is used to analyze the polarization change of a probe beam. The numerical results show that, for a linearly polarized probe beam with a frequency close to the band gap of GaAs crystal, its polarization rotation can be as large as 14 μrad under an applied electric field of about 350 V/mm. This effect should offer an alternative detection method for spintronics.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Reimagining pH Measurement: Utilizing Raman Spectroscopy for Enhanced Accuracy in Phosphoric Acid Systems

Measurement of pH is an integral component of chemical studies and process control; however traditional pH probes are difficult to utilize in harsh or complex chemical systems. Optical spectroscopy-based on-line monitoring offers a powerful and novel route for characterizing system parameters, such as pH, and is well adapted to deployment in harsh environments or chemically complex systems. Specifically, Raman spectroscopy combined with chemometric analysis can provide an improved method of on-line pH measurement. Therefore, multivariate curve resolution analysis of Raman spectra can be utilized to determine speciation as a function of pH and subsequent chemometric modeling can be used to correlate spectral response to pH. This was demonstrated with phosphoric acid, a chemical system known to challenge traditional pH probes. Raman spectra exhibit clear changes with pH due to changing speciation, and chemometric modeling can be successfully utilized to correlate those fingerprints to pH. Using this approach, true pH of the phosphoric acid system can be measured with greater accuracy than with traditional pH probes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Time-resolved in vivo luminescence dosimetry for online error detection in pulsed dose-rate brachytherapy

Purpose: The purpose of this study is to present and evaluate a dose-verification protocol for pulsed dose-rate (PDR) brachytherapy based on in vivo time-resolved (1 s time resolution) fiber-coupled luminescence dosimetry. Methods: Five cervix cancer patients undergoing PDR brachytherapy (Varian GammaMed Plus with {sup 192}Ir) were monitored. The treatments comprised from 10 to 50 pulses (1 pulse/h) delivered by intracavitary/interstitial applicators (tandem-ring systems and/or needles). For each patient, one or two dosimetry probes were placed directly in or close to the tumor region using stainless steel or titanium needles. Each dosimeter probe consisted of a small aluminum oxide crystal attached to an optical fiber cable (1 mm outer diameter) that could guide radioluminescence (RL) and optically stimulated luminescence (OSL) from the crystal to special readout instrumentation. Positioning uncertainty and hypothetical dose-delivery errors (interchanged guide tubes or applicator movements from {+-}5 to {+-}15 mm) were simulated in software in order to assess the ability of the system to detect errors. Results: For three of the patients, the authors found no significant differences (P>0.01) for comparisons between in vivo measurements and calculated reference values at the level of dose per dwell position, dose per applicator, or total dose per pulse. The standard deviations of the dose per pulse were less than 3%, indicating a stable dose delivery and a highly stable geometry of applicators and dosimeter probes during the treatments. For the two other patients, the authors noted significant deviations for three individual pulses and for one dosimeter probe. These deviations could have been due to applicator movement during the treatment and one incorrectly positioned dosimeter probe, respectively. Computer simulations showed that the likelihood of detecting a pair of interchanged guide tubes increased by a factor of 10 or more for the considered patients when going from integrating to time-resolved dose verification. The likelihood of detecting a {+-}15 mm displacement error increased by a factor of 1.5 or more. Conclusions: In vivo fiber-coupled RL/OSL dosimetry based on detectors placed in standard brachytherapy needles was demonstrated. The time-resolved dose-rate measurements were found to provide a good way to visualize the progression and stability of PDR brachytherapy dose delivery, and time-resolved dose-rate measurements provided an increased sensitivity for detection of dose-delivery errors compared with time-integrated dosimetry.

61 RADIATION PROTECTION AND DOSIMETRY↗

Design and performance of high-temperature furnace and cell holder for in situ spectroscopic, electrochemical, and radiolytic investigations of molten salts

To facilitate the development of molten salt reactor technologies, a fundamental understanding of the physical and chemical properties of molten salts under the combined conditions of high temperature and intense radiation fields is necessary. Optical spectroscopic (UV–Vis–near IR) and electrochemical techniques are powerful analytical tools to probe molecular structure, speciation, thermodynamics, and kinetics of solution dynamics. In this paper, we report the design and fabrication of three custom-made apparatus: (i) a multi-port spectroelectrochemical furnace equipped with optical spectroscopic and electrochemical instrumentation, (ii) a high-temperature cell holder for time-resolved optical detection of radiolytic transients in molten salts, and (iii) a miniaturized spectroscopy furnace for the investigation of steady-state electron beam effects on molten salt speciation and composition by optical spectroscopy. Initial results obtained with the spectroelectrochemical furnace (i) and high-temperature cell holder (ii) are reported.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Spatially Resolved Mapping of Three-Dimensional Molecular Orientations with ~2 nm Spatial Resolution through Tip-Enhanced Raman Scattering

We record local optical field images of silver nanocubes (75 nm) using tip-enhanced Raman (TER) spectral imaging. The images that we observe are consistent with several recent reports from our group, but here, we demonstrate sub-2 nm spatial resolution in local optical field nanoimaging under ambient laboratory conditions. This is achieved by scanning the substrate (nanocube on Si) relative to a 4-thiobenzonitrile (TBN)-functionalized Ag-coated TER probe. The spatial resolution that we obtain necessitates that only a few molecules govern the recorded optical response; molecular orientation becomes an important consideration in such measurements. We model the orientation through geometry optimization of a TBN molecule chemisorbed onto an Ag79 cluster (sphere with a ~1 nm diameter). Using the computed orientation of the cluster-bound molecule, we then model the optical response using formalism that accounts for the orientation of the molecule relative to vector components of the local optical fields. We find optimal agreement between experiment and theory. In effect, this work reveals the parallels between single-molecule Raman scattering and high-spatial-resolution TER spectroscopy, even when the images themselves cannot be used to visualize a single molecule in real space.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Electromagnetically induced blazed grating at low light levels

We propose a scheme for inducing a blazed transmission grating in a four-level, N-type atomic medium under electromagnetically induced transparency (EIT). The blazed grating relies on the giant Kerr nonlinearity that the atomic medium exhibits under EIT. The grating is created using an intensity mask in one of the driving optical fields and only weak fields with intensities below saturation level are involved. Diffraction efficiencies of a resonant probe beam close to 100% are predicted.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Through thick and thin: how optical cavities control spin

When light interacts with matter by means of scattering and absorption, we observe the resulting color. Light also probes the symmetry of matter and the result is encoded in its polarization. In the special case of circularly-polarized light, which is especially relevant in nonlinear optics, quantum photonics, and physical chemistry, a critical dimension of symmetry is along the longitudinal direction. We examine recent advances in controlling circularly-polarized light and reveal that the commonality in these advances is in judicious control of longitudinal symmetry. In particular, in the use of high quality-factor modes in dielectric metasurfaces, the finite thickness can be used to tune the modal profile. These symmetry considerations can be applied in multiplexed optical communication schemes, deterministic control of quantum emitters, and sensitive detection of the asymmetry of small molecules.

36 MATERIALS SCIENCE↗