Search NASA⌕ Search

SEARCH · Search NASA

Results for “Optimal Power Flow”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,783 records · Page 99

Innovating the next generation of commercial smart building software

Nearly 30% of commercial building energy use is wasted due to equipment faults and HVAC controls problems. The result is increased emissions, compromised comfort and productivity, and less reliable coordination of building power needs with a clean grid. The energy impact alone represents $17 billion in potential savings. Today’s smart building software provides a robust solution to address these operational deficiencies. Energy management and information systems (EMIS) are saving up to 9% on average, with two-year paybacks. They are being incorporated into energy management processes, commissioning services, and utility programs. As effective as they are, two barriers prevent even deeper benefits; limited personnel to fix problems once they are identified, and the expense and time to manually implement changes in control systems. In partnership with the research community, the EMIS industry is developing new capabilities to overcome these barriers. Moving beyond siloed products for either fault detection and diagnostics, or optimal control, these new capabilities empower users to not only automatically identify faults, but also to push corrective action, and control improvements to their buildings. In this paper, several areas for enhancements are documented: ‘one-time’ correction of faults such as setpoints, schedules, and economizer lockouts; short-term active testing for automated proportional integral derivative (PID) loop tuning and functional testing; and continuous supervisory control for demand flexibility and year-round efficiency. Results are presented from a pair of partner implementations out of a dozen providers integrating these enhancements into their products, including field tests from across the country, and insights into operator acceptance and integration into operations and maintenance practices.

Casillas, Armando↗

Diagnostic Cardiac Catheterization Using the MEDRAD Avanta™ Fluid Management System as Compared to the Traditional Manual Injection Method

Nearly 4 million patient procedures performed annually in US cardiac catheterization laboratories utilize contrast media to achieve vessel opacification. The amount of contrast media used is variable and depends on the complexity of the procedure, the method of contrast delivery as well as the skill-level of the operator. Since the total amount of contrast used for each procedure can have both patient safety and economic implications, it is essential for cardiologists to have the ability to control contrast delivery such that optimal angiographic image quality is achieved using the least amount of contrast. Although the complication rate associated with cardiac catheterization remains low, the most common serious complication, contrast-induced nephropathy (CIN), is associated with poor prognosis and a high mortality rate. Numerous interventional strategies for preventing and reducing the severity of CIN have demonstrated varying degrees of clinical benefit, but none has been shown to reliably prevent this serious complication. To date, the most effective approach for reducing the risk of CIN is to properly hydrate the patient and to minimize the amount of contrast media administered. Automated injection systems are intended for use in virtually all cardiac catheterization procedures and have numerous features which can provide potential advantages over traditional methods. With automated injection technology the operator is able to control and precisely monitor contrast delivery. Additionally, the MEDRAD Avanta Fluid Management Injection System utilizes a sterile contrast reservoir which eliminates the need to discard unused contrast in individual opened containers following each procedure. Considering that an average of 50% of opened contrast media is wasted using manual injection methods, this savings can provide a substantial economic benefit. Automated systems also facilitate the use of smaller (5 French) catheter sizes. Precise flow control and the use of smaller diameter catheters have both been shown to reduce the volume of contrast administered. The use of smaller size catheters also permits more rapid hemostasis, thus allowing shorter ambulation time without the need for costly wound closure devices. These factors can result in enhanced patient satisfaction as well as more efficient management of post-procedure rooms. The intent of this study was to demonstrate that using the MEDRAD Avanta™ Fluid Management Injection System (MEDRAD, INC., Pittsburgh, PA) for coronary diagnostic procedures can produce a reduction in the volume of contrast administered without loss of operational quality or efficiency. In addition, this study will explore procedure time and efficiency in an effort to minimize the amount of ionizing radiation delivered to the patient as well as the diagnostic team members. Study Design This is a post-market study designed to collect data during diagnostic cardiac catheterization when utilizing 5FR or 6FR catheters in conjunction with the Avanta Fluid Management System or a manual manifold injection method control group. A minimum of 420 patients scheduled for diagnostic cardiac catheterization will be enrolled in the study cohort. Patients will be assigned into the following two groups. Group 1: Catheterization with 5FR or 6FR catheters, using the traditional manual manifold injection method for contrast media delivery which is defined as manual hand injection of contrast media through a 3 or 4 port manifold and left ventriculography performed via standard fixed rate power injection. Group 2: Catheterization with 5FR or 6FR catheters, using the MEDRAD Avanta™ system for contrast media delivery. Study endpoints include volume of contrast media administered during diagnostic cardiac catheterization, volume of contrast media wasted post-procedure, procedure time (defined as the time from first catheter insertion to last diagnostic catheter removal), fluoroscopy time and angiographic image quality. The study demonstrated that use of the Advanta system reduced overall contrast utilization by decreasing the amount of contrast administered to the patient and reducing the amount of contrast wasted during preparation and post-procedure clean-up. The quality of the angiographic images and the radiation exposure to the patient were not affected.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The right conditions for high-precision dynamic temperature and heat capacity measurement via pyrometry and conductivity

The pursuit of accurate bulk temperature T under extreme conditions has been a long-standing goal of the high pressure science community, complicated by a lack of data to inform models. To reach these extremely high-pressure, high-temperature (high P − T) conditions, a combination of dynamic and heated static experiments (e.g., diamond or gem anvil cel experiments) are used. For example, in a diamond anvil cell (DAC) experiment, a sample placed in the DAC is first pressurized. Following pressurization, the sample T is increased either by heating the entire DAC (usually using resistive heating, and limited to ∼1000K) or by applying intense laser power to the sample surfaces. In a dynamic experiment, the process of pressurizing the sample also heats it. In the case of shock physics experiments, such heating is substantial, easily reaching thousands of Kelvin; in our work we have seen T ∼17000K. Most methods of measuring temperature at ambient are not compatible with experiments under these high-pressure, high-temperature conditions: thermocouples break, melt, or have conductivity properties that differ from ambient where they are calibrated; thermometers would melt; both are too slow. As a result most methods are based on non-contact techniques such as x-ray diffraction broadening, neutron scattering, or optical methods. Of these, optical methods using the visible and near-infrared region of the spectrum are the most commonly used as the sources and detectors are readily available. In the case of optical methods the optical depth, and therefore the measurement location, is limited to the surface. When a window or anvil material is used, heat flows from the sample into the window/anvil. Likewise, if the sample undergoes a change in thermodynamic state, such as expansion upon release, different T may be expected. As a result, the surface or apparent temperature T app measurement will differ from the bulk or interior temperature that is desired. This surface measurement must be related to the bulk measurement using thermal transport models and material models. While it is tempting to conclude that one should just use x-ray methods that directly probe the interior, even these methods have been shown to depend on thermal transport and material models. Regardless of the method used to create the high P − T condition, therefore, we must understand the role of thermal transport and material models upon our interpretation of the T measurement, as well as the errors and uncertainties associated with the choice of models used in the analysis. This is a substantial area of research and this paper is by no means a complete survey of the relevant sources of uncertainty. For example, we have yet to begin to address alternate transport models in a detailed manner (e.g., Tan-Ahrens), or the many models that use additional layers to approximate melting, turbulence, or epitaxial phenomena). Likewise, we have not explored the impact upon uncertainty of thermal models that use temperature-dependent thermal transport coefficients, or the wide range of material models that can be applied. Instead, this paper focuses on using one simple model, the Urtiew-Grover model, to understand the sources of error in T measurement so that we may identify how best to focus future research efforts to return the best improvements and avoid working on over-optimizing a single type of measurement. To this end, we work through some of the best and worst case scenarios for T measurement.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Evaluation of Hydrogen Production Feasibility for a Light Water Reactor in the Midwest

Increased electricity production from renewable energy resources coupled with low natural gas prices has caused existing light-water reactor (LWRs) to experience ever diminishing returns from the electricity market. Via partnership among Idaho National Laboratory (INL), The National Renewable Energy Laboratory (NREL), Argonne National Laboratory (ANL), Exelon, and Fuel Cell Energy a techno-economic analysis on the viability of retrofitting existing pressurized water reactors (PWRs) to produce hydrogen (H2) via high temperature steam electrolysis (HTSE) has been conducted. Such integration would allow nuclear facilities to expand into additional markets that may be more profitable in the long-term. To accommodate such an integration, a detailed analysis of HTSE process operation, requirements, and flexibility was conducted. Technical analysis includes proposed nuclear system control scheme modifications to allow dynamic operation of the HTSE via both thermal and electrical connection to the nuclear plant. High fidelity Modelica simulations showcase the viability of such control schemes. However, due to limited knowledge of solid oxide fuel cell (SOFC) stack degradation due to thermal gradients; thermal cycling of the HTSE was not included. Therefore, the control schemes proposed are only utilized to re-distribute steam at startup and only the portion of electricity utilized in the electrolyzers is cycled. From the detailed analysis of the nuclear integration and the HTSE process design, a comprehensive cost estimation was conducted in the APEA and H2A models to elucidate capital and operational costs associated with the production, compression, and distribution of hydrogen from a nuclear facility. Alongside this costing analysis, market analyses were conducted by NREL and ANL on the electric and hydrogen markets respectively in the PJM interconnect. Utilizing the electricity data market projections in the PJM interconnect from NREL and hydrogen demand/pricing projections from ANL a five variable sweep over component capacities, discount rates, and hydrogen pricing was completed using the stochastic framework RAVEN (Risk Analysis Virtual ENVironment) through its resource dispatch plugin HERON (Heuristic Energy Resource Optimization Network). Each combination of variables was evaluated stochastically four times over a seventeen year timespan from 2026-2042 (inclusive) to determine the most economically advantageous solution. Following the five variable sweep an optimization was conducted about the best sweep point to determine optimal component sizing and setpoints. Results suggest positive gain is achievable at all projected hydrogen market pricing levels and at all discount rates. However, exact component sizing and net returns vary based on these values and if incorrect sizing is selected; major net losses can occur. The optimal result occurred with set points as follows: high hydrogen prices, the largest possible HTSE unit in the sweep set at 7.47 kg/sec [645.4 tpd], a contractual hydrogen market agreement 7.29 kg/sec [629.8 tpd], and a hydrogen storage size 115,188 kg. The analysis suggested that with a discount rate of 8%, a ΔNPV = 1.2 billion over the seventeen year span can be achieved. The results illuminate that by operating in multiple markets the nuclear facility is capable of avoiding sale of electricity during times of low electricity market pricing, while maintaining the ability to capitalize on the high electricity market pricing. It should be noted that the analysis conducted in this report is a differential cash flow analysis and as such does not present profit levels. Instead it highlights the net benefit between building and competing in the hydrogen market utilizing nuclear facilities and conducting business as usual in the electricity markets. Additionally, results presented in this report exhibit conservatism due to four key assumptions: Given the limited knowledge on SOFC stack degradation due to thermal gradients the high temperature steam electrolysis plant is not allowed to thermally cycle. This limitation decreases electricity generation capacity in the nuclear plant, reducing capacity payments and the maximum output to the electrical grid. This analysis considers building a separate hydrogen pipeline for use in the nuclear facility. Research is currently being conducted to determine if existing natural gas pipelines can accommodate direct hydrogen injection. If hydrogen can be integrated into existing natural gas pipelines then a capital savings of ~$19,000,000 per kg/sec [1 kg/sec = 86.4 tpd] of installed HTSE capacity could be realized. Fast transients in the electric grid are typically served by flywheels and electric batteries. With electrolysis only operation the nuclear plant can flex its electricity just as quickly. However, for this analysis, the ancillary services market has been neglected. Should the nuclear plant have the ability to operate in the ancillary services market during periods when it is producing hydrogen, an additional substantial income stream that would increase overall system profitability could be considered. Subsidies for non-emitting generation technologies are not introduced in the cash flow analysis, but instead are completed assuming zero subsidies. Profitability is based solely on electricity pricing. Electric pricing is assumed to never go negative. Instead, it is assumed overall system curtailment by the Independent System Operator (ISO) will occur in such a manner that pricing remains at or above zero. This assumption inflates the “business as usual” scenario, thus decreasing the ΔNPV calculated. If negative pricing scenarios continue to occur as they do today, one would expect a further increase in ΔNPV. Overall, results advocate that, through market diversification, nuclear power plants have the potential to substantially increase current profit margins, increase market penetration, and ultimately solidify their place as a mainstay in energy production.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Enhancing Steam-Side Heat Transfer via Microdroplet Ejection using Inorganic Coatings

During condensation of water on a superhydrophobic nanostructured surfaces, droplets coalesce and jump (droplet ejection) due to the release of excess surface energy. Meticulously designed nanostructured surfaces or coatings capable of droplet ejection can enhance heat transfer performance by easy removal of droplets during condensation. In the present work, the capabilities of the Nelumbo droplet ejection coatings technology currently used in commercial heat exchangers are explored and optimized for materials and conditions relevant to steam condensers. Specifically, this includes (1) adapting and optimizing the procedures and chemistries to deposit droplet ejecting coatings on materials used in the steam condenser, (2) testing of the heat transfer, durability, and fouling of the fabricated coatings under a variety of steam condenser relevant conditions, and (3) modeling of the impact of droplet dynamics and interfacial properties on heat transfer in steam condensers. We experimentally demonstrated that at low supersaturation conditions (S~1.02), developed superhydrophobic nanostructured surface gives a 40% higher peak heat transfer flux and a 17% higher peak overall heat transfer coefficient (U) with droplet ejection mechanism compared to the dropwise condensation mechanism on the same nanostructured surface. Though the experimentally observed droplet ejection mechanism was short-lived (~3 min) due to the limitation of the chiller to maintain a constant supersaturation condition in fabricated steam condenser. And large variations in water inlet temperature (+ to - 2 degrees C) caused flooding of nanostructure (Wenzel state) at higher supersaturation (S > or = 1.12). This is an important finding because typical supersaturation levels in field operation are over 1.8 and as such, either the flooding potential for these materials should be improved or operation at lower supersaturation may be required to maximize heat transfer efficiency. If supersaturation conditions can be maintained reliably in the steam condenser in addition to droplet ejection mechanism during condensation, this could provide a potential 2% reduction in water flow rate which equates to a savings of over 3900 gallons of water per minute for a 500 MW steam turbine and over $0.3MM savings annually given a 0.02 cent marginal water withdrawal cost. It is also worth noting that these savings are based on improvement of droplet ejection coatings over coatings capable of performing consistent dropwise mechanism in in-field surface condensers. Savings due to the droplet ejections coatings when compared to bare substrates could be much higher. Additionally, the present work provides the importance of steam condenser operating conditions and insights into the challenges in modeling the condensing droplet dynamics on surfaces.

20 FOSSIL-FUELED POWER PLANTS↗

Monitoring system for the quality assessment in additive manufacturing

Additive Manufacturing (AM) refers to a process by which a set of digital data -representing a certain complex 3dim design - is used to grow the respective 3dim real structure equal to the corresponding design. For the powder-based EOS manufacturing process a variety of plastic and metal materials can be used. Thereby, AM is in many aspects a very powerful tool as it can help to overcome particular limitations in conventional manufacturing. AM enables more freedom of design, complex, hollow and/or lightweight structures as well as product individualisation and functional integration. As such it is a promising approach with respect to the future design and manufacturing of complex 3dim structures. On the other hand, it certainly calls for new methods and standards in view of quality assessment. In particular, when utilizing AM for the design of complex parts used in aviation and aerospace technologies, appropriate monitoring systems are mandatory. In this respect, recently, sustainable progress has been accomplished by joining the common efforts and concerns of a manufacturer Additive Manufacturing systems and respective materials (EOS), along with those of an operator of such systems (MTU Aero Engines) and experienced application engineers (Carl Metrology), using decent know how in the field of optical and infrared methods regarding non-destructive-examination (NDE). The newly developed technology is best described by a high-resolution layer by layer inspection technique, which allows for a 3D tomography-analysis of the complex part at any time during the manufacturing process. Thereby, inspection costs are kept rather low by using smart image-processing methods as well as CMOS sensors instead of infrared detectors. Moreover, results from conventional physical metallurgy may easily be correlated with the predictive results of the monitoring system which not only allows for improvements of the AM monitoring system, but finally leads to an optimisation of the quality and insurance of material security of the complex structure being manufactured. Both, our poster and our oral presentation will explain the data flow between the above mentioned parties involved. A suitable monitoring system for Additive Manufacturing will be introduced, along with a presentation of the respective high resolution data acquisition, as well as the image processing and the data analysis allowing for a precise control of the 3dim growth-process.

36 MATERIALS SCIENCE↗

CO{sub 2} Capture by Sub-ambient Membrane Operation

The main objective of the project was to develop a CO{sub 2} capture process based on sub-ambient temperature operation of a hollow fiber membrane. The program aims to reach the eventual DOE program goal of > 90% CO{sub 2} capture from existing PC fired power plants with < 35% increase in the cost of electricity. The project involves closed-loop testing of commercial fiber bundles under simulated process conditions to test the mechanical integrity and operability of membrane module structural component under sub ambient temperature. A commercial MEDAL 12” bundle exhibited excellent mechanical integrity for 2 months. However, selectivity was ~25% lower than expected at sub-ambient conditions. This could be attributed to a small feed to permeate leak or bundle non-ideality. To investigate further, and due to compressor flow limitations, the 12” bundle was replaced with a 6” bundle to conduct tests with lower permeate/feed ratios, as originally planned. The commercial 6” bundle was used for both parametric testing as well as long-term stability testing at sub-ambient conditions. Parametric studies were carried out both near the start and end of the long-term test. The parametric studies characterized membrane performance over a broad range of feed conditions: temperature (-25°C to -45°C), pressure (160 psig to 200 psig), and CO{sub 2} feed concentration (18% to 12%). Performance of the membrane bundle was markedly better at lower temperature (-45ºC), higher pressure (200 psig) and higher CO{sub 2} feed concentration (18%). The long-term test was conducted at these experimentally determined “optimum” feed conditions. Membrane performance was stable over 8 months at sub-ambient temperature operation. The experimentally measured high performance of the membrane bundle at sub-ambient operating conditions provides justification for interest in sub-ambient membrane processing of flue gas. In a parallel activity, the impact of contaminants (100 ppm SOx and NOx) on membrane performance was tested in the laboratory with membrane minipermeators. NO permeance is intermediate between CO{sub 2} and N{sub 2}; while both SO{sub 2} and NO{sub 2} are more permeable than CO{sub 2} at cold condition. This implies that SO{sub 2} and NO{sub 2} will be efficiently removed with CO{sub 2} into the membrane permeate in the proposed cold membrane process. Calculations were performed by Air Liquide Engineering (ALE) to estimate capture costs based on the proposed sub-ambient temperature membrane process for 90% CO{sub 2} capture from an air- fired coal power plant delivering 550 MW net electricity. Membrane performance in the process simulation was defined by the final parametric test results. This analysis involved refining the process simulation model, obtaining relevant capital cost estimates and using these to estimate a 20-year levelized cost of electricity (LCOE). A sensitivity analysis shows CO{sub 2} capture specific energy requirements of 216-242 kwh/T CO{sub 2} captured. The LCOE estimating methodology followed DOE/NETL study 2010/1397. This analysis indicates increases in LCOE between 48% and 53%. For most equipment, the budgetary capital cost estimates are expected to be valid within ± 20%. The most significant capital costs are due to the (i) feed compression and associated gas pretreatment and (ii) membrane system. For both items, there is a realistic chance for cost reductions in the immediate future (0-5 years) as well as long term reductions. The process continues to hold promise with anticipated cost reductions in compression and membrane operations. In particular, membrane costs could be reduced significantly by increased production volume (economy of scale) as well as optimization of bundle size and configuration for this application. PFD definition for a potential field test has been completed through (i) simulation work at DRTC, (ii) discussions with compressor manufacturers and (iii) a field visit to t e NCCC, Wilsonville, AL. The PC4 facility at the NCCC is a suitable site for a 0.1 MW scale test.

54 ENVIRONMENTAL SCIENCES↗

INTEGRATE - Inverse Network Transformations for Efficient Generation of Robust Airfoil and Turbine Enhancements

The INTEGRATE (Inverse Network Transformations for Efficient Generation of Robust Airfoil and Turbine Enhancements) project is developing a new inverse-design capability for the aerodynamic design of wind turbine rotors using invertible neural networks. This AI-based design technology can capture complex non-linear aerodynamic effects while being 100 times faster than design approaches based on computational fluid dynamics. This project enables innovation in wind turbine design by accelerating time to market through higher-accuracy early design iterations to reduce the levelized cost of energy. INVERTIBLE NEURAL NETWORKS Researchers are leveraging a specialized invertible neural network (INN) architecture along with the novel dimension-reduction methods and airfoil/blade shape representations developed by collaborators at the National Institute of Standards and Technology (NIST) learns complex relationships between airfoil or blade shapes and their associated aerodynamic and structural properties. This INN architecture will accelerate designs by providing a cost-effective alternative to current industrial aerodynamic design processes, including: - Blade element momentum (BEM) theory models: limited effectiveness for design of offshore rotors with large, flexible blades where nonlinear aerodynamic effects dominate - Direct design using computational fluid dynamics (CFD): cost-prohibitive - Inverse-design models based on deep neural networks (DNNs): attractive alternative to CFD for 2D design problems, but quickly overwhelmed by the increased number of design variables in 3D problems AUTOMATED COMPUTATIONAL FLUID DYNAMICS FOR TRAINING DATA GENERATION - MERCURY FRAMEWORK The INN is trained on data obtained using the University of Marylands (UMD) Mercury Framework, which has with robust automated mesh generation capabilities and advanced turbulence and transition models validated for wind energy applications. Mercury is a multi-mesh paradigm, heterogeneous CPU-GPU framework. The framework incorporates three flow solvers at UMD, 1) OverTURNS, a structured solver on CPUs, 2) HAMSTR, a line based unstructured solver on CPUs, and 3) GARFIELD, a structured solver on GPUs. The framework is based on Python, that is often used to wrap C or Fortran codes for interoperability with other solvers. Communication between multiple solvers is accomplished with a Topology Independent Overset Grid Assembler (TIOGA). NOVEL AIRFOIL SHAPE REPRESENTATIONS USING GRASSMAN SPACES We developed a novel representation of shapes which decouples affine-style deformations from a rich set of data-driven deformations over a submanifold of the Grassmannian. The Grassmannian representation as an analytic generative model, informed by a database of physically relevant airfoils, offers (i) a rich set of novel 2D airfoil deformations not previously captured in the data , (ii) improved low-dimensional parameter domain for inferential statistics informing design/manufacturing, and (iii) consistent 3D blade representation and perturbation over a sequence of nominal shapes. TECHNOLOGY TRANSFER DEMONSTRATION - COUPLING WITH NREL WISDEM Researchers have integrated the inverse-design tool for 2D airfoils (INN-Airfoil) into WISDEM (Wind Plant Integrated Systems Design and Engineering Model), a multidisciplinary design and optimization framework for assessing the cost of energy, as part of tech-transfer demonstration. The integration of INN-Airfoil into WISDEM allows for the design of airfoils along with the blades that meet the dynamic design constraints on cost of energy, annual energy production, and the capital costs. Through preliminary studies, researchers have shown that the coupled INN-Airfoil + WISDEM approach reduces the cost of energy by around 1% compared to the conventional design approach. This page will serve as a place to easily access all the publications from this work and the repositories for the software developed and released through this pr...

aerodynamics↗

Novel Carbon (C)-Boron (B)-Nitrogen (N)-Containing H2 Storage Materials

The following summarizes the research conducted for DOE project DE-EE0005658 “Novel Carbon(C)-Boron(B)-Nitrogen(N)-Containing H2 Storage Materials”. This work focused in part on the continued study of two materials identified from the preceding project DE-FG360GO18143 (“Hydrogen Storage by Novel CBN Heterocycle Materials”) as lead candidates to meet the DOE technical targets for either vehicular or non-automotive hydrogen storage applications. Specifically, a room-temperature liquid, 3-methyl-1,2-cyclopentane (B), and a high H2 capacity solid, 1,2-BN-cyclohexane (J), were selected for further characterization and performance optimization. In addition to these compounds, the current project also aimed to prepare several new materials predicted to be disposed towards direct reversibility of H2 release and uptake, a feature deemed critical to achieving efficient recycling of spent fuel end products. To assist in the rational design of these and other next-generation materials, this project undertook to investigate the mechanism of hydrogen release from established compounds (mainly B and J) using a combined experimental/computational approach. Among this project’s signature accomplishments, the preliminary synthetic route to B was optimized for production on decagram scale. With such quantities of material available, its performance in powering an actual 30 W proton exchange membrane (PEM) fuel cell stack was tested and found to be identical to that of facility H2. Despite this positive proof-of-concept achievement, however, further consideration of neat B as a potential hydrogen storage material was abandoned due to evidence of thermal instability. Specifically, mass spectrometry-coupled thermogravimetric analysis (TGA-MS) revealed significant H2 release from B to initiate at 50 °C, well below the 60 °C minimum threshold set by the DOE. This result prompted a more extensive investigation in the decomposition mechanism of B vis-à-vis that of J, which exhibited in neat form a substantially higher onset temperature for spontaneous H2 release (70 °C). Solution-phase kinetic experiments using ReactIR established a second-order dependence for the initial loss of H2 from both B and J; Arrhenius analysis, however, revealed the activation barrier for this reaction was lower for B than for J, which presumably contributes to the diminished thermal stability of the former. On the basis of these and other experimental results, extensive computational efforts yielded a reasonable mechanistic model for the dehydrogenation of 1,2-BN-cycloalkane materials. While the prospect of neat B as a suitable hydrogen storage material was discarded, it was proposed that the combination of B with more thermally stable amine-borane-based materials might afford mixtures with improved properties. Indeed, when B was combined with ammonia borane (AB) in a 2:1 molar ratio, the two materials formed a liquid. More significantly, this mixture remained liquid even after complete dehydrogenation, thus establishing the potential for a single-phase fuel cycle. (In contrast, the dehydrogenation product of neat B is a low melting solid (mp = 28-30 °C).) Another advantage conferred by the blend formulation was a dramatic reduction in the amount of borazine produced by AB. Borazine is a well-known contaminant of H2 produced by the thermal decomposition of neat AB, and exerts deleterious effects on fuel cell performance. Residual gas analysis (RGA) of the gas stream generated from the B-AB blend, however, detected just 0.01% borazine content when a Pt-Ni nanoparticle dehydrogenation catalyst was used. In all ii then, the 2:1 B-AB blend marks a major achievement in the effort to develop a suitable liquid amine-borane hydrogen storage material, and merits further investigation into the optimization for practical adoption. Similar realization of the potential of J as a high % wt. H2 material required a method to dehydrogenate the carbonaceous components of the molecule without the use of a sacrificial hydrogen acceptor, as had been reported in the previous project. Ultimately, this reaction was achieved for a B,N-disubstituted BN-cyclohexene model substrate using a gas flow system with a fixed Pd/C catalyst bed. Considerable work remains, however, to translate these initial results into a general protocol for complete dehydrogenation of fully saturated BN-cycloalkane materials such as J. With concrete confirmation of the possibility to perform both BN and CC dehydrogenation on a single theoretical substrate, COMSOL modeling was used to evaluate the effects of thermodynamically coupling the two reactions. It was hypothesized that the heat generated from exothermic BN dehydrogenation would partially drive the endothermic CC dehydrogenation reaction; this additional heat consumption was expected to in turn confer the benefit of lowering the maximum reactor temperature. A two-dimensional model of an axisymmetric reactor including experimental kinetic and calculated thermodynamic parameters for both reactions did indeed predict these outcomes. The extent to which the effects of thermodynamic coupling actually manifested, however, were also revealed to depend strongly on the relative rates of the two reactions, as well as the magnitude of the equilibrium constant governing the progress of the endothermic process. Given the evident complexity of attaining high effective % wt. H2 capacity with J, alternative systems were investigated for greater facility of extensive H2 release. Among those studied, 1,2,4,5-bis-BN-cyclohexane (H) demonstrated the most favorable properties, particularly with respect to thermal stability: rather than decompose, a neat sample instead sublimed when heated above 150 °C. Nevertheless, two commercially available catalytic systems were identified to effect release of two H2 equivalents from H. Release of further equivalents were apparently impeded by the formation of either polymeric material or one of two dimeric cage compounds depending on the catalyst used. Notably, a method to regenerate H from these product mixtures remains to be developed. Thus, while H may prove useful for certain long-term energy storage needs, it is currently less suited applications involving frequent fuel consumption. Similar difficulties were also encountered in attempts to realize the complete fuel cycle of 1,3-BN-cyclohexane (E) and B,N-substituted derivatives thereof. It had been initially proposed that E would provide for readily reversible BN dehydrogenation through a measure of frustrated Lewis pair-type character. Indeed, computations predicted this reaction would be essentially thermoneutral in solution. In the course of attempts to fully hydrogenate the spent fuel, however, dimeric species formed and proved resistant to further BN reduction. While a number of monomeric cyclic compounds were also successfully synthesized as formal boron-nitrogen frustrated Lewis pairs, none demonstrated any capacity to split H2 across the BN unit. The challenge of developing a practical amine-borane-based material for readily reversible hydrogen storage thus remains unresolved at this time. As such, it deserves consideration as a major objective of any future work.

08 HYDROGEN↗

A Microalgae-Based Platform for the Beneficial Re-use of Carbon Dioxide Emissions from Power Plants

This project sought to address the technical and economic barriers to carbon dioxide capture and utilization using microalgae. Operating data were collected in 2016 and 2017 during cultivation of Scenedesmus acutus at Duke Energy’s East Bend Station – a coal-fired power plant located in northern Kentucky – using flue gas as the CO 2 source. Algae were grown in a 1200 L “cyclic flow” photobioreactor (PBR) designed by the University of Kentucky. A key finding was that the harvested algae contained only very low concentrations of heavy metals (As, Cd, Hg, Se), consistent with heavy metals incorporation from the supplied nutrients. This indicates that algal biomass produced from coal-derived flue gas would be suitable for a variety of applications, including the production of bioplastics, use as fertilizer, etc. A lifecycle assessment showed that the UK-designed PBR employed in this work qualifies as a net CO 2 capture technology. Indeed, over a 30-year period, net CO 2 capture would equate to 43% of the targeted amount, i.e., the amount captured from the supplied flue gas. A techno-economic analysis indicated that the minimum production cost of Scenedesmus acutus biomass in the US is in the order of 875 USD/ton, excluding the cost of capital. While this figure is not too dissimilar to values reported for open raceway ponds in similar scenarios, it emphasizes that for current cultivation technology any pathway to economic viability will require applications for which algal boimass can be sold at prices in excess of 1,000 USD/ton. Currently, such applications represent relatively small markets, such as pigments (e.g., astaxanthin) and nutraceuticals (ω-3 unsaturated fatty acids), as well as nutritional supplements (whole algae) for human consumption and for use in pet food. Consequently, the commercialization of large-scale algae-based CO 2 capture and utilization will require the development of new technologies to reduce the cost of algae production and/or the development of new, high-value applications for algal biomass. One of the more promising applications for algal biomass is in the production of bioplastics. In this work, the potential for the algae grown in the East Bend PBR for the production of bioplastic with adequate mechanical properties was clearly shown. Positive features of the produced biomass included a high protein content and a composition that was generally more homogeneous than biomass grown in open ponds (in which many species may be present). The best candidate for further review, after incorporation into ethylene-vinyl acetate, was a lipid and sugar extracted material, which showed the highest extension values with comparable load values to other UK-derived samples. It also demonstrated extension benefits against the Algix Bloom product (currently offered commercially), even though it contained agglomerates which generally exert a negative effect on mechanical properties. This leads to speculation that with enhanced milling that exists on the commercial scale, the sugar and fat extracted product may be even more competitive. This, in turn, points to the need for additional work in order to assess the properties of such optimized algae-based plastics and the price point they can command.

09 BIOMASS FUELS↗

Integrated Experimental and Modeling Studies of Mineral Carbonation as a Mechanism for Permanent Carbon Sequestration in Mafic/Ultramafic Rocks

A program of laboratory experiments, modeling and fieldwork was carried out at Yale University, University of Maryland, and University of Hawai‘i, under a DOE Award (DE-FE0004375) to study mineral carbonation as a practical method of geologic carbon sequestration. Mineral carbonation, also called carbon mineralization, is the conversion of (fluid) carbon dioxide into (solid) carbonate minerals in rocks, by way of naturally occurring chemical reactions. Mafic and ultramafic rocks, such as volcanic basalt, are natural candidates for carbonation, because the magnesium and iron silicate minerals in these rocks react with brines of dissolved carbon dioxide to form carbonate minerals. By trapping carbon dioxide (CO 2 ) underground as a constituent of solid rock, carbonation of natural basalt formations would be a secure method of sequestering CO 2 captured at power plants in efforts to mitigate climate change. Geochemical laboratory experiments at Yale, carried out in a batch reactor at 200°C and 150 bar (15 MPa), studied carbonation of the olivine mineral forsterite (Mg 2 SiO 4 ) reacting with CO 2 brines in the form of sodium bicarbonate (NaHCO 3 ) solutions. The main carbonation product in these reactions is the carbonate mineral magnesite (MgCO 3 ). A series of 32 runs varied the reaction time, the reactive surface area of olivine grains and powders, the concentration of the reacting fluid, and the starting ratio of fluid to olivine mass. These experiments were the first to study the rate of olivine carbonation under passive conditions approaching equilibrium. The results show that, in a simple batch reaction, olivine carbonation is fastest during the first 24 hours and then slows significantly and even reverses. A natural measure of the extent of carbonation is a quantity called the carbonation fraction, which compares the amount of carbon removed from solution, during a run, to the maximum amount that could have been removed if the olivine initially present had fully dissolved and the cations released had subsequently precipitated in carbonate minerals. The carbonation fractions observed in batch experiments with olivine grains and powders varied significantly, from less than 0.01 (1%) to more than 0.5 (50%). Over time, the carbonation fractions reached an upper limit after about 24 to 72 hours of reaction, then stayed constant or decreased. The peak Final Scientific/Technical Report DE-FE0004275 | Mineral Carbonation | 4 coincided with the appearance of secondary magnesium-bearing silicate minerals, whose formation competes for magnesium ions in solution and can even promote conditions that dissolve magnesite. The highest carbonation fractions resulted from experiments with low ratios of concentrated solution to olivine, during which amorphous silica spheres or meshes formed, instead of secondary silicate minerals. The highest carbonation fractions appear to result from competing effects. Precipitation of silica layers on olivine reduces the reactive surface area and, thus, the rate of olivine dissolution (which ultimately limits the carbonation rate), but these same silica layers can also inhibit the formation of secondary silicate minerals that consume magnesite formed in earlier stages of carbonation. Simulation of these experiments with simple geochemical models using the software program EQ3/6 reproduces the general trends observed—especially the results for the carbonation fraction in short-run experiments. Although further experimentation and better models are needed, this study nevertheless provides a framework for understanding the optimal conditions for sequestering carbon dioxide by reacting CO 2 -bearing fluids with rocks containing olivine minerals. A series of experiments at the Rock Physics Laboratory at the University of Maryland studied the carbonation process during deformation of thermally cracked olivine-rich rock samples (dunite) saturated with CO 2 brines of varying compositions. A goal of these geomechanical experiments was to see if flow and deformation processes, which accompany natural carbonation reactions in underground settings, work to enhance or inhibit the reactions. The experiments involved hydrostatic compaction, followed by deformation at a constant rate of strain. Sample permeability was monitored during the reactions. Comparison of the samples’ volume changes to their axial strains (shortening) during deformation indicates that samples reacted with CO 2 -saturated brines accommodate more axial compaction, before the onset of dilation (a swelling that precedes rock failure), than samples reacted with distilled water. Analyses of the reacted samples with scanning electron microscope (SEM) images indicate, first, that dissolution of olivine occurring in the initial stages of carbonation can provide pathways to fluid flow that sustain the reaction, and, second, that carbonate minerals precipitated along existing fractures in the rocks may serve as asperities, or roughness on a crack’s surface that restricts its closure. Final Scientific/Technical Report DE-FE0004275 | Mineral Carbonation | 5 In a related study undertaken by one of the principal investigators as a spin-off of the main project, a simple model of (magnesite) crystal growth in the pore space of basalts undergoing carbonation was developed. The model suggests that, under a carefully controlled program of CO 2 injection, carbonate mineral growth can harden the rock formation against earthquakes that might otherwise be induced by the injection of large fluid volumes (Yarushina and Bercovici, 2013). The overall conclusion of the research project is that mineral carbonation of underground mafic and ultramafic rock formations is a viable candidate for long-term sequestration of man-made carbon dioxide. No results obtained during the project indicate that the method is inherently intractable in its implementation; moreover, enormous volumes of basalt near Earth’s surface are candidate locations for large-scale injection programs. The geochemical experiments do indicate, however, that there will be significant engineering challenges in maintaining high rates of carbonation, by delaying the onset of chemical conditions that promote formation of secondary silicate minerals and, therefore, slow down, or even reverse, the carbonation process. It remains an open question as to whether carbonation processes can be sustained for many years in an engineered system operating on a large scale—a scale capable of accommodating millions of tons of CO 2 annually. The development of realistic theoretical models that can systematically describe the combined effects of reactive flow, precipitation and geomechanical deformation is a major barrier to further understanding of the practical viability of mineral carbonation as large-scale method of carbon sequestration.

58 GEOSCIENCES↗

Integrated Heat Exchanger-Phase Change Material Thermal Energy Storage System

The purpose of this study is to experimentally investigate the thermal performance of an innovative thermal energy storage (TES) system that combines the advantages of the phase-change material (PCM)/graphite foam latent heat TES medium developed at Argonne National Laboratory (Argonne) and the internally supported plate-fin (ISPE) cell architecture heat transfer fluid (HTF) flow channels developed at Brayton Energy (Brayton). Several essential tasks were accomplished: (1) Thermal property characterization. Thermal properties of the graphite foam were characterized, providing necessary data for experimental result analysis and numerical simulation. (2) Design and optimization of lab-scale test module. Based on Brayton’s full-scale heat exchanger (HX)-TES system, the experimental test module was designed, optimized, and fabricated. (3) Thermal performance testing and data analysis. Five cycle tests were successfully conducted—including one with approximately 3.5 psig of pressure applied to the diaphragms—to investigate the thermal performance of the experimental test module for charging and discharging. Temperature profiles were generated for each charging test and discharging test as a function of time. The temperature profiles clearly show three TES stages: sensible heat (temperature increase), latent heat (melting), and sensible heat (temperature increase) for the charging process. Similarly, the temperature profiles clearly show three thermal energy release stages: sensible heat (temperature decrease), latent heat (solidification), and sensible heat (temperature decrease). Melting and solidification of the PCM generally occurred in relatively narrow temperature ranges, indicated by the flattened temperature regions in the temperature profiles. These phase changes ranged approximately 3°C for melting and 3.5°C for solidification. The charging and discharging temperature profiles were similar for similar experimental parameter tests whether or not pressure was applied to the diaphragm to eliminate the gap between the HX surface and the TES subsystem. This indicates that the effect of a small gap between the HX surface and the TES subsystem is insignificant for charging and discharging. (4) Comparison of experimental data and simulation results. We compared the experimental data to the numerical simulation results. Numerical simulations were conducted by using the ANSYS FLUENT 2019 R3 commercial computational fluid dynamics software. The predicted phase-change times agreed reasonably well with those from the experimental data. In most cases, the estimated time differences between the relative phase changes were within 16%. The predicted start and end times for the charging process agreed well with those from the experimental data. However, the simulation results showed earlier start and end times than the experimental data for the discharging process. Overall, the experimental data and its comparison with the simulation predictions verified the technical viability of the integrated ISPF HX-PCM/graphite foam latent-heat TES system.

25 ENERGY STORAGE↗

Light Material Interactions in Energy Conversion (Final Report)

The scientific vision of the “Light-Material Interactions in Energy Conversion” Energy Frontier Research Center (LMI-EFRC) is embodied in our mission statement: ‘to tailor the morphology, complex dielectric structure, and electronic properties of matter so as to sculpt the flow of sunlight and heat, enabling light conversion to electrical energy with unprecedented efficiency’. Founded in 2009, the LMI-EFRC has become a national resource for fundamental optical principles and phenomena relevant to solar energy conversion, addressing new scientific opportunities that enable efficient utilization of the entire visible and infrared solar resource. The LMI-EFRC is directed by Prof. Ralph Nuzzo and centered at its lead institution, the California Institute of Technology. The Center is an integrated and collaborative partnership of research leaders in photonics and photonic materials, comprising 14 faculty investigators that span six academic departments at five institutions, including Profs. Harry Atwater, Andrei Faraon, Nathan Lewis, and Austin Minnich at Caltech; Profs. Ralph Nuzzo, Paul Braun and John Rogers at the University of Illinois at Urbana-Champaign; Prof. Jennifer Lewis at Harvard University; Profs. Mark Brongersma, Jennifer Dionne, and Shanhui Fan at Stanford University; and Profs. Paul Alivisatos, Eli Yablonovitch, and Xiang Zhang at Lawrence Berkeley National Laboratory. The Center is organized into four research groups (RGs) that address scientific themes related to light-matter interactions, with each team spanning multiple institutional partners and designed to meet our scientific objectives. Notable project outcomes that address the LMI Mission and 2014-2018 goals include: (1) RG1 “New Light Management Mechanisms” demonstrated tunable and active nanostructured patterned surfaces (‘metasurfaces’) for control of light absorption, reflection, and propagation. (2) RG2 “Solar Spectrum Control and Conversion” developed colloidal nanocrystals with designer optical properties for fundamental studies of solar spectrum control and conversion. (3) RG3 “Thermal Photon Harvesting” established photonic design principles to harness and control thermal photons in novel conversion systems. (4) RG4 “Programmable Assembly of Photonic and Electronic Architectures” developed powerful new methods for light- and matter-based additive fabrication of electronic and photonic architectures.

14 SOLAR ENERGY↗

Final report of “A Detailed Study of the Physical Mechanisms Controlling CO2-Brine Capillary Trapping in the Subsurface” (University of Arizona, DE-SC0006696)

Carbon capture and storage (CCS) of carbon dioxide emissions generated by production or combustion of fossil fuels is a technologically viable means to reduce the build-up of CO2 in the atmosphere and oceans. Using advantages of scale and location, CCS is particularly suitable for large point sources near ubiquitous deep saline aquifers, depleted gas reservoirs, or at production reservoirs for enhanced oil recovery (EOR). In the BES-funded research project, Oregon State University (OSU) carried out capillary trapping experiments with proxy fluids that mimic the properties of the scCO2/brine system under ambient temperatures and pressures, and successfully developed a unique and novel x-ray compatible, high-pressure, elevated temperature setup to study the scCO2/brine system under challenging reservoir conditions. Both methodologies were applied to a variety of porous media, including synthetic (glass bead) and geologic (Bentheimer sandstone) materials. The University of Arizona (UA) developed pore-scale lattice Boltzmann (LB) models which are able to handle the experimental conditions for proxy fluids, as well as the scCO2/brine system, that are capable of simulating permeability in volumes of tens of millions of fluid elements. We reached the following summary findings (main institute indicated): 1. (OSU/UA) To understand capillary trapping in a multiphase fluid-porous medium system, the system must be analyzed from a pore-scale force balance perspective; trapping can be enhanced by manipulating wetting and nonwetting phase fluid properties. 2. (OSU) Pore-scale fluid connectivity and topology has a clear and direct effect on nonwetting phase capillary trapping efficiency. 3. (OSU) Rock type and flow regime also have a pronounced effects on capillary trapping. 4. (OSU/UA) There is a predictable relationship between NWP connectivity and NWP saturation, which allows for development of injection strategies that optimize trapping. The commonly used Land model (Land, 1968) does not predict amount of trapped NWP accurately. 5. (UA) There are ambiguities regarding the segmentation of large-volume gray-scale CT data into pore-volumes suitable for pore-scale modeling. Simulated permeabilities vary by three orders of magnitude and do not resemble observed values very well. Small-volume synchrotron-based CT data (such as produced by OSU) does not suffer significantly from segmentation ambiguities. 6. (UA) A standard properly parameterized Shan-Chen model LB model is useful for simulating porous media with proxy fluids as well as the scCO2/brine system and produces results that are consistent with tomographic observations. 7. (UA) A LB model with fluid-interactions defined by a (modified) Peng-Robinson Equation of State is able to handle the scCO2/brine system with variable solid phase wettability. This model is numerically stable at temperatures between 0 and 250 °C and pressures between 3 and 50 MPa, and produces appropriate densities above the critical point of CO2 and exhibits three-phase separation below. Based on above findings OSU and UA have proposed continued experimentation and pore-scale modeling of the scCO2/brine system. The reported research has extensively covered capillary trapping using proxy fluids, but due to limited beam-time availability we were unable to apply our high-pressure CO2 setup to sufficient variation in fluid properties, and initial scCO2 connectivity. New data will also allow us to test, calibrate and apply our LB models to reservoir conditions beyond those that are currently feasible experimentally. Such experiments and simulations will also allow us to provide information how suitable proxy fluids are for the scCO2/brine system. We believe it would be worthwhile to pursue the following new research questions: 1. What are the fundamental differences in the physics underlying capillary trapping at ambient vs. supercritical conditions? 2. Do newly developed pore-scale trapping interactions and relationships translate to continuum scales? A motivation for these questions was elaborated in “Capillary Trapping of Super-Critical CO2: Linking Pore and Continuum Scales to Verify new Relationships” that was submitted to DOE-BES in 2015.

20 FOSSIL-FUELED POWER PLANTS↗

Performance of Variable Capacity Heat Pumps in a Mixed Humid Climate

Variable capacity heat pumps represent the next wave of technology for heat pumps. In this report, the performance of two variable capacity heat pumps (HPs) is compared to that of a single or two stage baseline system. The units were installed in two existing research houses located in Knoxville, TN. These houses were instrumented to collect energy use and temperature data while both the baseline systems and variable capacity systems were installed. The homes had computer controlled simulated occupancy, which provided consistent schedules for hot water use and lighting. The temperature control and energy use of the systems were compared during both the heating and cooling seasons. Multiple linear regression models were used along with TMY3 data for Knoxville, TN in order to normalize the effect that the outdoor air temperature has on energy use. This enables a prediction of each system's energy use over a year with the same weather. The first system was a multi-split system consisting of 8 indoor units and a single outdoor unit. This system replaced a 16 SEER single stage HP with a zoning system, which served as the baseline. Data was collected on the baseline system from August 2009 to December 2010 and on the multi-split system from January 2011 to January 2012. Soon after the installation of the multi-split system, some of the smaller rooms began over-conditioning. This was determined to be caused by a small amount of continuous refrigerant flow to all of the indoor units when the outdoor unit was running regardless of whether they were calling for heat. This, coupled with the fact that the indoor fans run continuously, was providing enough heat in some rooms to exceed the set point. In order to address this, the indoor fans were disabled when not actively heating per the manufacturer's recommendation. Based on the measured data, the multi-split system was predicted to use 40% more energy in the heating season and 16% more energy in the cooling season than the baseline system, for the typical meteorological year weather data. The AHRI ratings indicated that the baseline system would perform slightly better than the multi-split system, but not by as large of a margin as seen in this study. The multi-split system was able to maintain more consistent temperature throughout the house than the baseline system, but it did allow relative humidity levels to increase above 60% in the summer. The second system was a split system with an inverter driven compressor and a single ducted air handler. This unit replaced a 16 SEER two stage HP with a zoning system. Data was collected on the baseline system from July 2009 to November 2010 and on the ducted inverter system from December 2010 to January 2012. The ducted inverter system did not offer a zone controller, so it functioned as a single zone system. Due to this fact, the registers had to be manually adjusted in order to better maintain consistent temperatures between the two levels of the house. The predicted heating season energy use for the ducted inverter system, based on the measured energy use, was 30% less than that of the baseline system for the typical meteorological year. However, the baseline system was unable to operate in its high stage due to a wiring issue with the zone controller. This resulted in additional resistance heat use during the winter and therefore higher energy use than would be expected in a properly performing unit. The AHRI ratings would indicate that the baseline system would use less energy than the ducted inverter system, which is opposite to the results of this study. During the cooling season, the ducted inverter system was predicted to use 23% more energy than the baseline system during the typical meteorological year. This is also opposite of the results expected by comparing the AHRI ratings. After a detailed comparison of the ducted inverter system's power use compared to that of a recently installed identical system at a retro-fit study house, there is concern that the unit is not operating as intended. The power use and cycles indicate that the unit is performing more like a single stage unit than a variable capacity unit. Analysis of the data indicates that a change in operating behavior occurred during a service call shortly after the installation of the unit. The logbook only indicates that refrigerant charge was added, but does not indicate any other change. This is being investigated further. While the energy comparison results of these two variable capacity heat pumps is generally underwhelming, it is difficult to draw any hard conclusions about the maximum attainable efficiency of these units when optimally installed. Both units appear to have undesirable conditions associated with the installation or operation, which could have had an adverse effect on their energy use.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Prototype Modeling for a Light-Trapping Planar-Cavity Enclosed Particle Solar Receiver

Concentrating solar thermal (CST) systems present a promising avenue for affordable and reliable energy production. Solar receivers are key components that determine the efficiency and longevity of these systems. Particle-based solar receivers have emerged as a compelling alternative to traditional technologies, offering several advantages that address limitations in current CST systems. This is especially true as next-generation CST technologies target applications including electricity generation, thermochemical processes, and industrial process heat, many of which necessitate higher operating temperatures than current commercial molten salt systems. Molten-salt thermal energy storage (TES) systems, commonly used in CSP, face challenges related to freezing and corrosion. Particle-based TES systems, in contrast, do not experience these issues, as particles are stable at high temperatures, exceeding 1000 degrees Celsius. This capability allows for a wider range of applications, including those requiring higher temperatures for industrial processes and efficient electricity generation. A novel innovation in particle-based solar receiver technology is the light-trapping planar cavity receiver (LTPCR) configuration developed by NREL. The LTPCR design consists of small cavity-like structures using opaque planar surfaces, enabling efficient capture and absorption of solar energy. A high incident flux concentration at the cavity aperture is absorbed on the receiver walls, and subsequently transferred to particles on the inside of cavities. The particles flow through the system, forming a fluidized bed inside of the receiver panels, effectively capturing the absorbed solar heat. Air is used as a fluidizing medium in this process to enhance particle heat transfer and mixing. The effectiveness of this design lies in its ability to manage solar flux conditions and ensure high solar-to-thermal receiver efficiency. A 100-kW prototype is currently being tested at the King Saud University in Saudi Arabia to assess the receiver performance. A range of modeling analyses for the optical, thermal, and mechanical effects were conducted to assess the performance of the receiver under on-sun conditions. The solar flux resulting from the KSU heliostat field was modeled using NREL SolTrace software and produced up to 600 kW/m2 at the receiver aperture. The solar flux absorbed on the receiver walls was then used within a computational fluid dynamics (CFD) model to predict wall temperature distributions along with radiation and convection loss. A two-phase CFD model was developed for the fluidized bed of silica sand inside the receiver panels to predict local wall-to-particle heat transfer coefficients, particle temperature distributions, and outlet temperature of the particles. We have also conducted analyses to understand the thermomechanical behavior of these innovative enclosed light-trapping solar receivers optimized for particle heating. We used finite element analysis (FEA) to predict the receiver's performance using temperature distributions obtained from CFD and based on the resulting stress profiles, evaluated creep-fatigue damage with a goal of achieving a 30-year service life. Analysis showed a significant impact of the particle-to-wall heat transfer coefficients (HTCs) on receiver performance, with higher HTCs resulting in reduced stress and increased lifespan. For instance, when using Inconel 740H, increasing the HTC from 800 W/m2 K to 1400 W/m2 K increased the creep life from 4,000 hours to over 100,000 hours. This highlights the importance of understanding and optimizing heat transfer in the design of high-efficiency receivers.

14 SOLAR ENERGY↗

Computational Analysis of the X-57 Maxwell Airplane at Unpowered Conditions (Preliminary Fuselage)

The X-57 Maxwell is an all-electric airplane that implements a distributed electric propulsion system to demonstrate that high-efficiency electric propulsion can be integrated with aerodynamics to increase the performance of an airplane. To this end, distributed electric fans were installed on the wing to provide increased flow over the wing at the low takeoff and landing speeds of the X-57. The low-speed lift augmentation allows for a reduction in wing area for cruise optimization. The X-57 wing area was reduced to 42 percent of the wing area of the baseline aircraft, a Tecnam P2006T. With this reduced wing area and the electric propulsion system, it is estimated that the X-57 will cruise on less than one-third the total energy compared to the baseline aircraft. To meet the cruise performance goal at a Mach number of 0.233 at an altitude of 8000 feet, the X-57 has a cruise lift coefficient of 0.7516 and needs to have a cruise drag coefficient of 0.05423 or less. The USM3D computational solver was used to investigate the X-57 performance, without the distributed electric propulsion high-lift system operating. The unpowered X-57 performance is of interest to quantify if the X-57 can meet the cruise drag performance goal, and to document the lift performance of the very small wing at takeoff and landing conditions. The primary configurations investigated in this paper include the cruise configuration with no flap deflection, a takeoff configuration with a 10◦ flap deflection, and a landing configuration with a 30◦ flap deflection. The conditions for the cruise configuration were a flight unit Reynolds number of 1.32E+06 per foot, an altitude of 8000 feet, a Mach number of 0.233, and angles of attack from −2° to 24° . At the cruise lift coefficient of 0.7516, the computed drag coefficient is 0.05275. This computed drag is less than the drag coefficient of 0.05423 that is required to meet the X-57 airplane performance goal. However, the computational airplane is a completely smooth geometry and does not account for protuberance drag, nor the drag from steps and gaps in the actual X-57 airplane. Therefore, based upon the CFD drag calculation there is a 10-percent margin to account for some of the differences between the as-built metal fuselage and empennage construction, and the smooth computational geometry. The computed cruise drag also does not account for an induced drag reduction due to the wing-tip propellers and a drag reduction due to laminar flow achieved on the wing. The computed lift to drag ratio is 14.14 at the cruise lift coefficient of 0.7516, and the maximum computed lift to drag ratio is 15.8. The maximum lift coefficient for the cruise configuration was 2.13 at an angle of attack of 15°. The conditions for the takeoff configuration with a 10° flap deflection were a flight unit Reynolds number of 0.986E+06 per foot, an altitude of 2500 feet, a Mach number of 0.149, and angles of attack from −2° to 22°. The maximum lift coefficient for the takeoff configuration was 2.21 at an angle of attack of 16°. The conditions for the landing configuration with a 30° flap deflection were a flight unit Reynolds number of 0.922E+06 per foot, an altitude of 2500 feet, a Mach number of 0.139, and angles of attack from −2° to 24°. The maximum lift coefficient for the landing configuration was 2.58 and occurred at two angles of attack, 10° and 14°. Based on the unpowered maximum lift coefficient of 2.58 for the 30° flap deflection, along with computations of the distributed electric propulsion lift augmentation (not shown in this paper), the X-57 Maxwell is estimated to meet its powered landing goal of a maximum lift coefficient of 4.0.

X-57 Maxwell Airplane↗

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗