Search NASA⌕ Search

SEARCH · Search NASA

Results for “PROXIMITY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,783 records · Page 99

Advancing Environmental Flow Science: Developing Frameworks for Altered Landscapes and Integrating Efforts Across Disciplines

Environmental flows represent a legal mechanism to balance existing and future water uses and sustain non-use values. Here, we identify current challenges, provide examples where they are important, and suggest research advances that would benefit environmental flow science. Specifically, environmental flow science would benefit by (1) developing approaches to address streamflow needs in highly modified landscapes where historic flows do not provide reasonable comparisons, (2) integrating water quality needs where interactions are apparent with quantity but not necessarily the proximate factor of the ecological degradation, especially as frequency and magnitudes of inflows to bays and estuaries, (3) providing a better understanding of the ecological needs of native species to offset the often unintended consequences of benefiting non-native species or their impact on flows, (4) improving our understanding of the non-use economic value to balance consumptive economic values, and (5) increasing our understanding of the stakeholder socioeconomic spatial distribution of attitudes and perceptions across the landscape. Environmental flow science is still an emerging interdisciplinary field and by integrating socioeconomic disciplines and developing new frameworks to accommodate our altered landscapes, we should help advance environmental flow science and likely increase successful implementation of flow standards.

54 ENVIRONMENTAL SCIENCES↗

Successful Percutaneous Transluminal Angioplasty and Stenting in Acute Mesenteric Ischemia

Acute mesenteric ischemia (AMI) is a life-threatening emergency. The complications are high by the time of diagnosis in most cases and therefore only few data on primary percutaneous intervention with percutaneous transluminal angioplasty (PTA) and stenting in AMI are available. We present the case of an 84-year-old woman who presented to our emergency department complaining of an acute worsening of pre-existing abdominal periumbilical pain, nausea, vomiting, and diarrhea. She had previously undergone percutaneous transluminal embolectomy for an acute occlusion of the left common femoral artery. Due to suspicion of intestinal infarction, conventional angiography of the aorta and the superior mesenteric artery (SMA) was performed and confirmed a proximal occlusion of the SMA. Percutaneous SMA recanalization with balloon dilation and subsequent stent implantation was carried out successfully. The abdominal symptoms subsided after this procedure. In AMI that is diagnosed early, endovascular stenting should be considered as an alternative treatment to the surgical approach that avoids the need for surgical bowel resection.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Endovascular Treatment of Anastomotic Pseudoaneurysms after Aorto-iliac Surgical Reconstruction

Purpose. To assess the effectiveness of endovascular treatment of anastomotic pseudoaneurysms (APAs) following aorto-iliac surgical reconstruction. Materials. We retrospectively evaluated 21 men who, between July 2000 and March 2006, were observed with 30 APAs, 13 to the proximal anastomosis and 17 to the distal anastomosis. The patients had had previous aorto-iliac reconstructive surgery with a bypass due to aneurysm (15/21) or obstructive disease (6/21). The following devices were used: 12 bifurcated endoprostheses, 2 aorto-monoiliac, 4 aortic extenders, 1 stent-graft leg, and 2 covered stents. Follow-up was performed with CT angiography at 1, 3, and 6 months after the procedure and yearly thereafter. Results. Immediate technical success was 100%. No periprocedural complications occurred. Four patients died during follow-up from causes not related to APA, and 1 (treated for prosthetic-enteric fistula) from sepsis 3 months after the procedure. During a mean follow-up of 19.7 months (range 1-72 months), 2 of 21 occlusions of stent-graft legs occurred 3 and 24 months after the procedure (treated with thrombolysis and percutaneous transluminal angioplasty and femorofemoral bypass, respectively) and 1 type I endoleak. Primary clinical success rate was 81% and secondary clinical success was 91%. Conclusion. Endovascular treatment is a valid alternative to open surgery and can be proposed as the treatment of choice for APAs, especially in patients who are a high surgical risk. Further studies with larger series and longer follow-up are necessary to confirm the long-term effectiveness of this approach.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Early Results of Endovascular Treatment of the Thoracic Aorta Using the Valiant Endograft

Endovascular repair of the thoracic aorta has been adopted as the first-line therapy for much pathology. Initial results from the early-generation endografts have highlighted the potential of this technique. Newer-generation endografts have now been introduced into clinical practice and careful assessment of their performance should be mandatory. This study describes the initial experience with the Valiant endograft and makes comparisons with similar series documenting previous-generation endografts. Data were retrospectively collected on 180 patients treated with the Valiant endograft at seven European centers between March 2005 and October 2006. The patient cohort consisted of 66 patients with thoracic aneurysms, 22 with thoracoabdominal aneurysms, 19 with an acute aortic syndrome, 52 with aneurysmal degeneration of a chronic dissection, and 21 patients with traumatic aortic transection. The overall 30-day mortality for the series was 7.2%, with a stroke rate of 3.8% and a paraplegia rate of 3.3%. Subgroup analysis demonstrated that mortality differed significantly between different indications; thoracic aneurysms (6.1%), thoracoabdominal aneurysms (27.3%), acute aortic syndrome (10.5%), chronic dissections (1.9%), and acute transections (0%). Adjunctive surgical procedures were required in 63 patients, and 51% of patients had grafts deployed proximal to the left subclavian artery. Comparison with a series of earlier-generation grafts demonstrated a significant increase in complexity of procedure as assessed by graft implantation site, number of grafts and patient comorbidity. The data demonstrate acceptable results for a new-generation endograft in series of patients with diverse thoracic aortic pathology. Comparison of clinical outcomes between different endografts poses considerable challenges due to differing case complexity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Long-Term Follow-Up After Endovascular Treatment of Acute Aortic Emergencies

Purpose. To investigate the long-term outcome and efficacy of emergency treatment of acute aortic diseases with endovascular stent-grafts. Methods. From September 1995 to April 2007, 37 patients (21 men, 16 women; age 53.9 {+-} 19.2 years, range 18-85 years) with acute complications of diseases of the descending thoracic aorta were treated by endovascular stent-grafts: traumatic aortic ruptures (n = 9), aortobronchial fistulas due to penetrating ulcer or hematothorax (n = 6), acute type B dissections with aortic wall hematoma, penetration, or ischemia (n = 13), and symptomatic aneurysm of the thoracic aorta (n = 9) with pain, penetration, or rupture. Diagnosis was confirmed by contrast-enhanced CT. Multiplanar reformations were used for measurement of the landing zones of the stent-grafts. Stent-grafts were inserted via femoral or iliac cut-down. Two procedures required aortofemoral bypass grafting prior to stent-grafting due to extensive arteriosclerotic stenosis of the iliac arteries. In this case the bypass graft was used for introduction of the stent-graft. Results. A total of 46 stent-grafts were implanted: Vanguard/Stentor (n = 4), Talent (n = 31), and Valiant (n = 11). Stent-graft extension was necessary in 7 cases. In 3 cases primary graft extension was done during the initial procedure (in 1 case due to distal migration of the graft during stent release, in 2 cases due to the total length of the aortic aneurysm). In 4 cases secondary graft extensions were performed-for new aortic ulcers at the proximal stent struts (after 5 days) and distal to the graft (after 8 months) and recurrent aortobronchial fistulas 5 months and 9 years after the initial procedure-resulting in a total of 41 endovascular procedures. The 30-day mortality rate was 8% (3 of 37) and the overall follow-up was 29.9 {+-} 36.6 months (range 0-139 months). All patients with traumatic ruptures demonstrated an immediate sealing of bleeding. Patients with aortobronchial fistulas also demonstrated a satisfactory follow-up despite the necessity for reintervention and graft extension in 3 of 6 cases (50%). Two patients with type B dissection died due to mesenteric ischemia despite sufficient mesenteric blood flow being restored (but too late). Two suffered from neurologic complications, 1 from paraplegia and 1 from cerebral ischemia (probably embolic), 1 from penetrating ulcer, and 1 from persistent ischemia of the kidney. Five of 9 (56%) patients with symptomatic thoracic aneurysm demonstrated endoleaks during follow-up and there was an increase in the aneurysm in 1. Conclusion. Endovascular treatment is safe and effective for emergency treatment of life-threatening acute thoracic aortic syndromes. Results are encouraging, particularly for traumatic aortic ruptures. However, regular follow-up is mandatory, particularly in the other pathologies, to identify late complications of the stent-graft and to perform appropriate additional corrections as required.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Direct Percutaneous Jejunostomy-An Underutilized Interventional Technique?

Our aim in this study was to report our single-center experience with direct percutaneous jejunostomy over a 4-year period with regard to technical success rate, immediate and late complications, and patient tolerance of the procedure. Institutional records of 22 consecutive patients who underwent radiological insertion of a percutaneous jejunostomy for a variety of indications were reviewed. The proximal jejunum was punctured under either fluoroscopic or ultrasonic guidance, and following placement of retention sutures, a 10- to 12-Fr catheter inserted. There was a 100% technical success rate in placement involving a total of seven operators. The indications for placement were prior gastric resection, newly diagnosed resectable esophageal or gastric carcinoma, unresectable gastric carcinoma with outlet obstruction, and palliative drainage of bowel obstruction. Mean duration of follow-up was 100 days, and catheter placement 57.7 days. There were six minor early complications, consisting of loss of two retention anchors requiring repuncture, three cases of localized excessive postprocedural pain, and one failed relief of symptoms of small bowel obstruction. Four tubes developed late complications (two blocked, one catheter cracked, and one inadvertently pulled out). Three of the four were successfully replaced through the existing tracts. One patient subsequently developed a minor skin infection, while another developed late pericatheter leakage from ascites. We conclude that direct percutaneous jejunostomy is a valuable treatment modality applicable to a number of clinical scenarios, with a high technical success rate and low serious complication rate.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

How Safe is Bilateral Internal Iliac Artery Embolization Prior to EVAR?

Purpose. To assess the outcomes of patients after bilateral internal iliac artery (IIA) embolization prior to endovascular aneurysm repair (EVAR). Methods. Thirty-nine patients (age range 55-88 years, mean 72.5 years; 2 women) underwent IIA embolization/occlusion before EVAR. There were 28 patients with aorto-biiliac aneurysms and 6 with bilateral common iliac artery (CIA) aneurysms. Five patients with unilateral CIA aneurysms had previous surgical ligation of the contralateral IIA or inadvertent covering by the stent-graft of the contralateral IIA origin. Outcomes were assessed by clinical follow-up. Results. Severe ischemic complications were limited to spinal cord ischemia in 1 patient (3%) who developed paraparesis following EVAR. No other severe ischemic complications such as buttock necrosis, or bowel or bladder ischemia, occurred. Buttock and/or thigh claudication occurred in 12 patients (31%) and persisted beyond 1 year in 3 patients (9%). Sexual dysfunction occurred in 2 patients (5%). Patients who underwent simultaneous embolization had a 25% (3/12) ischemic complication rate versus 41% (11/27) in those with sequential embolization (p = 0.48). Embolization limited to the main trunk of the IIA resulted in a significantly reduced ischemic complication rate of 16% (3/19) versus 55% (11/20) of patients who had a more distal embolization of the IIA (p = 0.019, Fisher's exact test). Conclusion. Severe complications after bilateral IIA embolization are uncommon. Although buttock/thigh claudication occurs in around 30% of patients soon after the procedure, this resolves in the majority after 1 year. There is no obvious benefit for sequential versus simultaneous IIA embolization in our series. Occlusion of the proximal IIA trunk is associated with reduced complications compared with occlusion of the distal IIA.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Modified Metallic Coil Embolization Technique for Pulmonary Arteriovenous Malformations Using Coil Anchors and Occlusion Balloon Catheters

Purpose. To evaluate the feasibility and efficacy of a modified metallic coil embolization technique for pulmonary arteriovenous malformations (PAVMs) using coil anchors and occlusion balloon catheters. Methods. Five consecutive female patients with 6 PAVMs were included in the present study. One of the 6 PAVMs was of the complex type with four feeding arteries. An occlusion balloon catheter was inserted into the feeding artery as close to the venous sac as possible. The coil anchor, which was a simple W-shaped bent stainless steel wire with two markers at each end, was deployed prior to embolization to prevent the systemic migration of embolic materials. Then, metallic coils were deployed around the coil anchors under inflow stoppage using the inflated occlusion balloon catheter. In the complex-type PAVM, the main feeder was occluded by this technique and the other three small feeders were embolized with metallic coils only. Results. In all 5 cases, occlusion balloon catheters could be inserted into the feeding arteries just proximal to the venous sacs, coil anchors were easily deployed, and complete occlusion was achieved without any migration of metallic coils or paradoxical embolism during the procedure. Conclusions. The modified metallic coil embolization technique with coil anchors and occlusion balloon catheters was feasible and considered to be useful in preventing procedure-related complications.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Transcatheter Coil Embolization of Splenic Artery Aneurysm

The purpose of this study was to evaluate clinical results and technical problems of transcatheter coil embolization for splenic artery aneurysm. Subjects were 16 patients (8 men, 8 women; age range, 40-80 years) who underwent transcatheter embolization for splenic artery aneurysm (14 true aneurysms, 2 false aneurysms) at one of our hospitals during the period January 1997 through July 2005. Two aneurysms (12.5%) were diagnosed at the time of rupture. Multiple splenic aneurysms were found in seven patients. Aneurysms were classified by site as proximal (or strictly ostial) (n = 3), middle (n = 3), or hilar (n = 10). The indication for transcatheter arterial embolization was a false or true aneurysm 20 mm in diameter. Embolic materials were fibered coils and interlocking detachable coils. Embolization was performed by the isolation technique, the packing technique, or both. Technically, all aneurysms were devascularized without severe complications. Embolized aneurysms were 6-40 mm in diameter (mean, 25 mm). Overall, the primary technical success rate was 88% (14 of 16 patients). In the remaining 2 patients (12.5%), partial recanalization occurred, and re-embolization was performed. The secondary technical success rate was 100%. Seven (44%) of the 16 study patients suffered partial splenic infarction. Intrasplenic branching originating from the aneurysm was observed in five patients. We conclude that transcatheter coil embolization should be the initial treatment of choice for splenic artery aneurysm.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Use of a Re-Entry Catheter in Recanalization of Chronic Inflow Occlusions of the Common Iliac Artery

Endovascular treatment of iliac artery occlusions can be unsuccessful due to a failure to break back into the true lumen, and lesions without a proximal stump can be particularly problematic. True lumen re-entry catheters have not been previously used for this type of lesion. The authors report eight patients, five males and three females, with lifestyle-limiting intermittent claudication referred for endovascular treatment. Imaging demonstrated unilateral chronic total occlusion of the common iliac artery in six patients and two patients with short patent stumps at the origin of the occluded common iliac artery. Endovascular therapy was initially unsuccessful due to an inability to re-enter the true lumen after crossing the occlusion in the subintimal plane. With the assistance of the Outback LTD catheter it was possible to achieve continuity of the dissecting tract with the true lumen, thus facilitating successful primary stenting in all eight patients. To our knowledge this is the first report of the use of the Outback LTD catheter in this type of lesion.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A New Ischemic Model Using a Radiofrequency Wire Electrode in a Rabbit Hindlimb

The purpose of this study was to establish an ischemic rabbit hindlimb model using a radiofrequency (RF) wire electrode. We inserted a polytetrafluoroethylene-coated wire with a 2-cm exposed tip into the left superficial femoral artery of seven New Zealand white rabbits and performed RF ablation (RFA) while pulling the wire back. We assessed the clinical findings, angiography, computed tomography perfusion, and permeability surface until 6 weeks after RFA. The angiography demonstrated complete obstruction from the proximal external iliac artery to the distal superficial femoral artery and showed a gradual increment in the angiogenic score, which represents the degree of angiogenesis (r = 0.86, p < 0.0001). The left-to-right ratios of the computed tomography perfusion and permeability surface were significantly reduced after 4 days (p < 0.05), and then they gradually increased with time. We conclude that endovascular RFA using an RF wire electrode is a reproducible and measurable way to create an ischemic rabbit hindlimb model.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Intraoperative DynaCT Detection and Immediate Correction of a Type 1a Endoleak Following Endovascular Repair of Abdominal Aortic Aneurysm

Reintervention following endovascular aneurysm repair (EVAR) is required in up to 10% of patients at 30 days and is associated with a demonstrable risk of increased mortality. Completion angiography cannot detect all graft-related anomalies and computed tomographic angiography is therefore mandatory to ensure clinical success. Intraoperative angiographic computed tomography (DynaCT; Siemens, Germany) utilizes cone beam reconstruction software and flat-panel detectors to generate CT-like images from rotational angiographic acquisitions. We report the intraoperative use of this novel technology in detecting and immediately treating a proximal anterior type Ia endoleak, following an endovascular abdominal aortic repair, which was not seen on completion angiography. Immediate evaluation of cross-sectional imaging following endograft deployment may allow for on-table correction of clinically significant stent-related complications. This should both improve technical success and minimize the need for early secondary intervention following EVAR.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Coronary Events and Anatomy After Arterial Switch Operation for Transposition of the Great Arteries: Detection by 16-Row Multislice Computed Tomography Angiography in Pediatric Patients

The purpose of this study was to evaluate the feasibility of multislice computed tomographic (MSCT) angiography as a noninvasive method for detecting ostial, proximal, and middle segment coronary stenosis or occlusion and anatomy in patients with transposition of the great arteries who had undergone arterial switch operation (ASO). Sixteen-detector-row MSCT angiography was performed in 16 patients treated with ASO for transposition of the great arteries. The median age was 10.3 years (range, 6.2-16.3 years). Sixteen-detector-row MSCT angiography was performed in 16 patients who had undergone ASO. CT imaging was performed in the craniocaudal direction from 2 cm above the carina up to the heart basis. Noninvasive assessment of coronary artery stenosis and anatomy were investigated by MSCT angiography. Two patients were excluded from the study because of artifacts. Of 14 evaluated patients, 1 patient had ostial stenosis (7.1%). A coronary artery anatomy variant was present in six patients: left main artery (LMA) and right coronary artery (RCA) originating from the right sinus as a single orifice (n = 2); left circumflex artery (LCX) originating from the RCA (n = 1); LMA and RCA, after branching to the LCX, originating separately from the right sinus (n = 1); and LMA (n = 1) and left anterior descending artery (LADA; n = 1) originating directly from the right sinus. Intramural bridging in the LAD (n = 2) was detected. Five patients were normal. In conclusion, MSCT angiography, as a noninvasive, feasible technique for assessing coronary stenosis or occlusion and anatomy, can be used in the follow-up of patients who have undergone ASO.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Portal Vein Embolization Using a Nitinol Plug (Amplatzer Vascular Plug) in Combination with Histoacryl Glue and Iodinized Oil: Adequate Hypertrophy with a Reduced Risk of Nontarget Embolization

The purpose of this study was to assess whether portal vein embolization (PVE) using a nitinol vascular plug in combination with histoacryl glue and iodinized oil minimizes the risk of nontarget embolization while obtaining good levels of future liver remnant (FLR) hypertrophy. Between November 2005 and August 2008, 16 patients (8 females, 8 males; mean age, 63 {+-} 3.6 years), each with a small FLR, underwent right ipsilateral transhepatic PVE prior to major hepatectomy. Proximal PVE was initially performed by placement of a nitinol vascular plug, followed by distal embolization using a mixture of histoacryl glue and iodinized oil. Pre- and 6 weeks postprocedural FLR volumes were calculated using computed tomographic imaging. Selection for surgery required an FLR of 0.5% of the patient's body mass. Clinical course and outcome of surgical resection for all patients were recorded. At surgery, the ease of hepatectomy was subjectively assessed in comparison to previous experience following PVE with alternative embolic agents. PVE was successful in all patients. Mean procedure time was 30.4 {+-} 2.5 min. Mean absolute increase in FLR volume was 68.9% {+-} 12.0% (p = 0.00005). There was no evidence of nontarget embolization during the procedure or on subsequent imaging. Nine patients proceeded to extended hepatectomy. Six patients demonstrated disease progression. One patient did not achieve sufficient hypertrophy in relation to body mass to undergo hepatic resection. At surgery, the hepatobiliary surgeons observed less periportal inflammation compared to previous experience with alternative embolic agents, facilitating dissection at extended hepatectomy. In conclusion, ipsilateral transhepatic PVE using a single nitinol plug in combination with histoacryl glue and iodinized oil simplifies the procedure, offering short procedural times with minimal risk of nontarget embolization. Excellent levels of FLR hypertrophy are achieved enabling safe extended hepatectomy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Bifurcated Endograft (Excluder) in the Treatment of Isolated Iliac Artery Aneurysm: Preliminary Report

The aim of this study was to evaluate the effectiveness of endovascular repair in the treatment of isolated iliac artery aneurysm (IAA) using Excluder bifurcated endograft. Eight consecutive patients with IAA were treated during a period of 45 months using Excluder bifurcated endograft. Two patients presented with isolated IAA rupture and were treated emergently, whereas the other six patients underwent elective treatment. All aneurysms lacked sufficient proximal necks and therefore were not suitable for tubular-shaped endograft. Follow-up imaging was performed at 1 week, at every 3 months during the first year, semiannually until 2 years, and annually afterward using angio-computed axial tomography and plain films. Technical success was achieved in all patients. No mortality was seen despite two patients having IAA rupture. Follow-up (12 to 60 months) was done in all but one patient. During this period, complications were observed in three patients. One patient developed sexual impotence at 3-month follow up; one patient presented unilateral gluteal claudication after the procedure, which resolved at 3 months; and one patient developed a graft porosity-related endoleak, which was successfully managed with placement of an additional ipsilateral iliac extension. Endovascular treatment of isolated IAA using bifurcated endograft is safe and can be an alternative to surgical treatment. The benefits from decreased morbidity and mortality of endoluminal treatment of isolated IAA using bifurcated endograft outweigh the minor complications associated with this technique, which are mostly related to occlusion of hypogastric arteries.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Hepatocellular Carcinoma Supplied by the Right Lumbar Artery

This study evaluated the clinical features of hepatocellular carcinoma (HCC) supplied by the right lumbar artery. Eleven patients with HCC supplied by the right lumbar artery were treated with chemoembolization. The patients' medical records were retrospectively analyzed. All patients underwent 6.7 {+-} 3.7 (mean {+-} SD) chemoembolization sessions, and the hepatic arterial branches were noted as being attenuated. The right inferior phrenic artery (IPA) was also embolized in 10 patients. The interval between initial chemoembolization and chemoembolization of the lumbar artery supply was 53.2 {+-} 26.9 months. Mean tumor diameter was 3.1 {+-} 2.4 cm and was located at the surface of S7 and S6. The feeding-branch arose proximal to the bifurcation of the dorsal ramus and muscular branches (n = 8) or from the muscular branches (n = 3) of the right first (n = 10) or second lumbar artery (n = 1). The anterior spinal artery originated from the tumor-feeding lumbar artery in one patient. All feeders were selected, and embolization was performed after injection of iodized oil and anticancer drugs (n = 10) or gelatin sponge alone in a patient with anterior spinal artery branching (n = 1). Eight patients died from tumor progression 10.1 {+-} 4.6 months later, and two patients survived 2 and 26 months, respectively. The remaining patient died of bone metastases after 32 months despite liver transplantation 10 months after chemoembolization. The right lumbar artery supplies HCC located in the bare area of the liver, especially in patients who undergo repeated chemoembolization, including chemoembolization by way of the right IPA. Chemoembolization by way of the right lumbar artery may be safe when the feeder is well selected.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiocephalic Fistula Complicated by Distal Ischemia: Treatment by Ulnar Artery Dilatation

Hand ischemic steal syndrome due to a forearm arteriovenous fistula is a rare occurrence. However, its frequency is increasing with the rise in numbers of elderly and diabetic patients. This complication, which is more common for proximal than for distal accesses, can be very severe and may cause loss of hand function, damage to fingers, and even amputation of fingers or the hand. Its treatment is difficult and often leads to access loss. We report here a case of severe hand ischemia related to a radiocephalic fistula successfully treated by ulnar artery dilatation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Case of Late Femoral Pseudoaneurysm Caused by Stent Disconnection

We present the case of a late superficial femoral artery stent disconnection causing an asymptomatic pseudoaneurysm successfully treated with a stent-graft. A 67-year-old female was referred to our department for evaluation of claudication of the left lower limb and was diagnosed to have a total occlusion of the superficial femoral artery. Three nitinol stents were used to revascularize this artery. At 48 months, duplex-ultrasonography control revealed the presence of a 45-mm saccular femoral dilatation; X-rays and CT angiography showed fractures of the proximal stents and the presence of a pseudoaneurysm at the site of the distal stents disconnection. The pseudoaneurysm was excluded using two stent-grafts. We conclude that patients and surgeons should be aware of structural complications with all stents. Rigorous follow-up controls should be mandatory. Endovascular repair proved to be feasible and durable to manage a previous endovascular procedure.

62 RADIOLOGY AND NUCLEAR MEDICINE↗