Search NASA⌕ Search

SEARCH · Search NASA

Results for “Particle detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,783 records · Page 99

Atmospheric tau neutrinos in a multikiloton liquid argon detector

An ultralarge liquid argon time projection chamber based neutrino detector will have the uncommon ability to detect atmospheric {nu}{sub {tau}}/{nu}{tau} events. This paper discusses the most promising modes for identifying charged current {nu}{sub {tau}}/{nu}{tau}, and shows that, with simple kinematic cuts, {approx}30 {nu}{sub {tau}}+{nu}{tau} interactions can be isolated in a 100 kt{center_dot}yr exposure, with greater than 4{sigma} significance. This sample is sufficient to perform flux-averaged total cross-section and cross-section shape parametrization measurements--the first steps toward using {nu}{sub {tau}}/{nu}{tau} to search for physics beyond the standard model.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The LUX direct dark matter search

As evidenced by the numerous contributions on the topic at this meeting, the IX International Conference on Interconnections between Particle Physics and Cosmology (PPC2015), the direct detection of dark matter remains as one of the highest priorities in both particle physics and cosmology. In 2013 the LUX direct dark matter search collaboration reported the most stringent constraints to-date on the spin-independent WIMP–nucleon interaction cross section. Here we present a summary of that work, describe recent technical improvements, and results from new calibrations. Prospects for the future of the LUX scientific program are reported, together with the outlook for its successor project, LZ.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Magnetic moment of {sup 104}Ag{sup m} and the hyperfine magnetic field of Ag in Fe using nuclear magnetic resonance on oriented nuclei

Nuclear magnetic resonance (NMR/ON) measurements with beta- and gamma-ray detection have been performed on oriented {sup 104}Ag{sup g,m} nuclei with the NICOLE {sup 3}He-{sup 4}He dilution refrigerator setup at ISOLDE/CERN. For {sup 104}Ag{sup g} (I{sup p}i=5{sup +}) the gamma-NMR/ON resonance signal was found at nu=266.70(5) MHz. Combining this result with the known magnetic moment for this isotope, the magnetic hyperfine field of Ag impurities in an Fe host at low temperature (<1 K) is found to be |B{sub hf}(AgFe)|=44.709(35) T. A detailed analysis of other relevant data available in the literature yields three more values for this hyperfine field. Averaging all four values yields a new and precise value for the hyperfine field of Ag in Fe; that is, |B{sub hf}(AgFe)|=44.692(30) T. For {sup 104}Ag{sup m} (I{sup p}i=2{sup +}), the anisotropy of the beta particles provided the NMR/ON resonance signal at nu=627.7(4) MHz. Using the new value for the hyperfine field of Ag in Fe, this frequency corresponds to the magnetic moment mu({sup 104m}Ag)=+3.691(3) mu{sub N}, which is significantly more precise than previous results. The magnetic moments of the even-A {sup 102-110}Ag isotopes are discussed in view of the competition between the (pig{sub 9/2}){sub 7/2}{sup +-3}(nud{sub 5/2}nug{sub 7/2}){sub 5/2}{sup +} and the (pig{sub 9/2}){sub 9/2}{sup +-3}(nud{sub 5/2}nug{sub 7/2}){sub 5/2}{sup +} configurations. The magnetic moments of the ground and isomeric states of {sup 104}Ag can be explained by an almost complete mixing of these two configurations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Parity violation in composite inelastic dark matter models

Recent experimental results indicate that the dark matter sector may have a nonminimal structure with a spectrum of states and interactions. Inelastic scattering has received particular attention in light of DAMA's annual modulation signal. Composite inelastic dark matter (CiDM) provides a dynamical origin for the mass splittings in inelastic dark matter models. We show that higher dimensional operators in the CiDM Lagrangian lead to an admixture of inelastic and elastic scattering in the presence of parity violation. This scenario is consistent with direct detection experiments, even when parity violation is nearly maximal. We present an effective field theory description of such models and discuss the constraints from direct detection experiments. The CiDM model with parity violation has nontrivial phenomenology because of the multiple scattering channels that are allowed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Cosmic-Ray Signatures of Dark Matter Decay

In light of recent observations of an anomalous excess of high-energy positrons and electrons by the PAMELA and Fermi LAT experiments, we investigate exotic cosmic-ray signatures in scenarios with unstable dark matter that decays with an extremely long lifetime. We identify decay modes capable of explaining the observed anomalies and mention constraints arising from measurements of antiprotons and gamma rays. We also discuss complementary tests by measurements of anisotropies in diffuse gamma rays which should be accessible to Fermi.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Internal Heterogeneous Processes in Aluminum Combustion

This paper discusses the aluminum particle combustion mechanism which has been expanded by inclusion of gas dissolution processes and ensuing internal phase transformations. This mechanism is proposed based on recent normal and microgravity experiments with particles formed and ignited in a pulsed micro-arc. Recent experimental findings on the three stages observed in Al particle combustion in air and shows the burning particle radiation, trajectory (streak), smoke cloud shapes, and quenched particle interiors are summarized. During stage I, the radiation trace is smooth and the particle flame is spherically symmetric. The temperature measured using a three-color pyrometer is close to 3000 K. Because it exceeds the aluminum boiling point (2730 K), this temperature most likely characterizes the vapor phase flame zone rather than the aluminum surface. The dissolved oxygen content within particles quenched during stage I was below the detection sensitivity (about 1 atomic %) for Wavelength Dispersive Spectroscopy (WDS). After an increase in the radiation intensity (and simultaneous decrease in the measured color temperature from about 3000 to 2800 K) indicative of the transition to stage II combustion, the internal compositions of the quenched particles change. Both oxygen-rich (approx. 10 atomic %) and oxygen-lean (< 1 %) regions are identified within the particles using back-scattered electron imaging and WDS. During stage II, oscillations are observed in particle radiation and the flame and smoke cloud are distorted from their original spherically-symmetric shape. In stage III, particle radiation continues to exhibit oscillations, but its radiation intensity drops and remains at a nearly constant level. The measured temperature decreases to about 2300 K. Also, larger changes in particle velocities are observed, and oxide caps are found on quenched particle surfaces. While these results showed the correlation between the aluminum particle combustion behavior and the evolution of its internal composition, the change from the spherically symmetric to asymmetric flame shape occurring upon the transition from stage I to stage II combustion could not be understood based only on the fact that dissolved oxygen is detected in the particles. The connection between the two phenomena appeared even less significant because in earlier aluminum combustion studies carried in O2/Ar mixtures, flame asymmetry was not observed as opposed to experiments in air or O2/CO mixtures. It has been proposed that the presence of other gases, i.e., hydrogen, or nitrogen causes the change in the combustion regime.

Dreizin, E. L.↗

Exploring the Potential of Residual Impurities in Germanium Detectors for MeV-Scale Dark Matter Detection

Abstract The direct detection of MeV-scale dark matter (DM) particles hinges on achieving an exceptionally low-energy detection threshold. Germanium (Ge) detectors, meticulously tailored with precise impurity compositions, hold the potential to enhance sensitivity to energy levels below the sub-electronvolt (sub-eV) range. This study explores the behavior of residual impurities inherent to Ge detectors at helium temperatures, unveiling a captivating freeze-out phenomenon leading to the formation of excited localized states known as dipole states. Using compelling evidence from relative capacitance measurements obtained from two detectors, we elucidate the transition of impurity atoms from free charge states to these dipole states as the temperature drops from 11 to 6.5 K. Our investigation comprehensively covers the intricate formation of these dipole states in bothn-type andp-type impurities. Furthermore, we shed light on the electric field generated by these dipole states, revealing their ability to trap charges and facilitate the creation of cluster dipole states. Confirming findings from previous measurements, we establish that these excited dipole states exhibit a binding energy of less than 10 meV, offering an exceptionally low detection threshold for MeV-scale DM. Building upon this concept, we propose the development of a 1-kg Ge detector with internal charge amplification—an innovative approach poised to surpass electrical noise and enable the detection of MeV-scale DM with unprecedented sensitivity.

Physics↗

Single-particle chemical analysis reveals organic-rich detonation soot products

The detonation of high explosives produces a wide variety of particulate matter (PM) with distinct properties, not all of which are traditionally studied for chemical composition, formation processes, and forensic applications. We report particle-resolved measurements of Composition B detonation soot using soot particle aerosol mass spectrometry (SP-AMS), identifying carbonaceous species and metals not previously characterized on a single-particle basis. Results are combined with scanning electron microscopy with energy dispersive X-ray spectroscopy (SEM-EDS) to enhance source-dependent signatures. Black carbon, including graphitic carbon and detonation nanodiamonds, contributed 50.5-71.4% of PM 2.5 mass, while 22.5-43.4% was non-refractory organic carbon, a previously overlooked component that exhibited a complex and varying composition. Detonations were performed with and without PMMA confinement and under steady and overdriven conditions. Distinct particles enriched with polycyclic aromatic hydrocarbons (PAHs) were observed in experiments utilizing confinement, with quantities dependent on manufacturing method. SEM-EDS validated SP-AMS findings of metals internally mixed with carbonaceous species and extended the particle size range to 100 µm. This work makes detecting non-refractory organics using single-particle techniques more feasible for detonation forensics and understanding high-energy soot formation. While this analysis uses offline sample collection, SP-AMS could be deployed for in-situ measurements of detonation PM 2.5 transported in the atmosphere.

36 MATERIALS SCIENCE↗

Forward Drift Chamber for the GlueX Experiment at the 12 GeV CEBAF Machine

The GlueX experiment will search for exotic mesons produced by 9 GeV linearly polarized photons from the upgraded CEBAF machine. It is critical to detect and measure the four-momenta of all the charged particles and photons resulting from the decays of the mesons. The solenoid-based detector system includes tracking detectors and calorimeters. The Forward Drift Chamber, FDC, consists of 24 circular planar drift chambers of 1m diameter. Additional cathode readout is required to achieve efficient pattern recognition. The detection of photons by the electromagnetic calorimeters imposes constraints on the amount of material used in the FDC. The specific features of the detector and the readout electronics will be described. Results from the tests of the full scale prototype will be presented, as well.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Improved Limits on Spin-Dependent WIMP-Proton Interactions from a Two Liter CF{sub 3}I Bubble Chamber

Data from the operation of a bubble chamber filled with 3.5 kg of CF{sub 3}I in a shallow underground site are reported. An analysis of ultrasound signals accompanying bubble nucleations confirms that alpha decays generate a significantly louder acoustic emission than single nuclear recoils, leading to an efficient background discrimination. Three dark matter candidate events were observed during an effective exposure of 28.1 kg day, consistent with a neutron background. This observation provides strong direct detection constraints on weakly interacting massive particle (WIMP)-proton spin-dependent scattering for WIMP masses >20 GeV/c{sup 2}.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dark matter annihilation rates with velocity-dependent annihilation cross sections

The detection of by-products from particle annihilations in galactic halos would provide important information about the nature of the dark matter. Observational evidence for a local excess of high-energy positrons has motivated recent models with an additional interaction between dark matter particles that can result in a Sommerfeld enhancement to the cross section. In such models, the cross section for annihilation becomes velocity-dependent and may enhance the dark matter annihilation rate in the solar neighborhood relative to the rate in the early Universe sufficiently to source observed fluxes of high-energy positrons. We demonstrate that, for particle interaction cross sections that increase with decreasing velocity, the kinematical structures of dark matter halos with interior density profiles shallower than isothermal, such as Navarro-Frenk-White or Einasto halos, may induce a further enhancement owing to the position-dependent velocity distribution. We provide specific examples for the increase in the annihilation rate with a cross section enhanced by the Sommerfeld effect. In dark matter halos like that of the Milky Way and Local Group dwarf galaxies, the effective cross section at the halo center can be significantly larger than its local value. The additional enhancement owing to halo kinematics depends upon the parameters of any model, but is a prediction of certain models aimed at explaining measured positron fluxes and can exceed an order of magnitude.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Detector Simulation and WIMP Search Analysis for the Cryogenic Dark Matter Search Experiment

Astrophysical and cosmological measurements on the scales of galaxies, galaxy clusters, and the universe indicate that 85% of the matter in the universe is composed of dark matter, made up of non-baryonic particles that interact with cross-sections on the weak scale or lower. Hypothetical Weakly Interacting Massive Particles, or WIMPs, represent a potential solution to the dark matter problem, and naturally arise in certain Standard Model extensions. The Cryogenic Dark Matter Search (CDMS) collaboration aims to detect the scattering of WIMP particles from nuclei in terrestrial detectors. Germanium and silicon particle detectors are deployed in the Soudan Underground Laboratory in Minnesota. These detectors are instrumented with phonon and ionization sensors, which allows for discrimination against electromagnetic backgrounds, which strike the detector at rates orders of magnitude higher than the expected WIMP signal. This dissertation presents the development of numerical models of the physics of the CDMS detectors, implemented in a computational package collectively known as the CDMS Detector Monte Carlo (DMC). After substantial validation of the models against data, the DMC is used to investigate potential backgrounds to the next iteration of the CDMS experiment, known as SuperCDMS. Finally, an investigation of using the DMC in a reverse Monte Carlo analysis of WIMP search data is presented.

79 ASTRONOMY AND ASTROPHYSICS↗

Sub-GLE Solar Particle Events and the Implications for Lightly-Shielded Systems Flown During an Era of Low Solar Activity

Many of the large space missions must be very rigorous in their designs to reduce risk from radiation damage as much as possible. Some ways of reducing this risk have been to build in multiple redundancies, purchase/develop radiation hardened electronics parts, and plan for worst case radiation environment scenarios. These methods work well for these ambitious missions that can afford the costs associated with these meticulous efforts. However, there have been more small spacecraft and CubeSats with smaller duration missions entering the space arena, which can take some additional risks, but cannot afford to implement all of these risk-reducing methods. Therefore, one way to quantify the radiation exposure risk for these smaller spacecraft would be to investigate the radiation environment pertinent to the mission to better understand these radiation exposures, rather than always designing to the infrequent, worst-case environment. In this study, we have investigated 34 historical solar particle events (1974-2010) that occurred during a time period when the sun spot number (SSN) was less than 30. These events contain Ground Level Events (GLE), sub-GLEs, and sub-sub-GLEs(sup 1-3). GLEs are extremely energetic solar particle events (SPEs) having proton energies often extending into the several GeV range and producing secondary particles in the atmosphere, mostly neutrons, observed with ground station neutron monitors. Sub-GLE events are less energetic, extending into the several hundred MeV range, but without producing detectable levels of secondary atmospheric particles. Sub-sub GLEs are even less energetic with an observable increase in protons at energies greater than 30 MeV, but no observable proton flux above 300 MeV. The spectra for these events were fitted using a double power law fit in particle rigidity, called the Band fit method. The differential spectra were then input into the NASA Langley Research Center HZETRN 2005, which is a high-energy particle transport/dose code, to determine the dose in various thicknesses of aluminum, representing the spacecraft. This paper will detail the absorbed dose results of each of these environments, as well as analyze the data to better understand the doses over small thicknesses that are more relevant to small spacecraft and satellites, such as CubeSats. In addition, we will discuss the implications of these data and provide some recommendations that may be useful to spacecraft designers of these smaller spacecraft/CubeSat-type missions.

Atwell, William↗

Recoil-Implantation Of Multiple Radioisotopes Towards Wear Rate Measurements And Particle Tracing In Prosthetic Joints

This study demonstrates a new method of radioisotope labeling of ultra-high molecular weight polyethylene inserts in prosthetic joints for wear studies. The radioisotopes {sup 97}Ru, {sup 100}Pd, {sup 100}Rh, and {sup 101m}Rh are produced in fusion evaporation reactions induced by {sup 12}C ions in a {sup 92}Zr target foil. The fusion products recoil-implant into ultra-high molecular weight polyethylene plugs, machined to fit into the surface of the inserts. During laboratory simulations of the joint motion, a wear rate of the labeled polyethylene may be measured and the pathways of wear debris particles can be traced by detecting characteristic gamma-rays. The concentration profiles of the radioisotopes extend effectively uniformly from the polyethylene surface to a depth of about 4 {mu}m. The multiplicity of labeling and the use of several gamma-ray lines aids with avoiding systematic measurement uncertainties. Two polyethylene plugs were labeled and one was fitted into the surface of the tibial insert of a knee prosthesis, which had been worn in. Actuation over close to 100,000 cycles with a 900 N axial load and a 24 deg. flexion angle removed (14{+-}1)% of the gamma-ray activity from the plug. Most of this activity dispersed into the serum lubricant identifying this as the important debris pathway. Less than 1% activity was transferred to the femoral component of the prosthesis and the measured activity on the tibial tray was insignificant. Assuming uniform wear across the superior surface of the insert, a wear rate of (12{+-}3) mm{sup 3}/Megacycle was determined. This is consistent with wear rate measurements under similar conditions using other techniques.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Detection of thermal neutrons with a CMOS pixel sensor for a future dosemeter

The RaMsEs group (Radioprotection et Mesures Environnementales) is developing a new compact device for operational neutron dosimetry. The electronic part of the detector is made of an integrated active pixel sensor, originally designed for tracking in particle physics. This device has useful features for neutrons, such as high detection efficiency for charged particles, good radiation resistance, high readout speed, low power consumption and high rejection of photon background. A good response of the device to fast neutrons has already been demonstrated [1]. In order to test the sensibility of the detector to thermal neutrons, experiments have been carried out with a 512 x 512 pixel CMOS sensor on a californium source moderated with heavy water (Cf.D{sub 2}O) on the Van Gogh irradiator at the LMDN, IRSN, Cadarache (France)). A thin boron converter is used to benefit from the significant cross section of the {sup 10}B (n,{alpha}) {sup 7}Li reaction. Results show a high detection efficiency (around 10{sup -3}) of the device to thermal neutrons. Our measurements are in good agreement with GEANT4 Monte Carlo simulations. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fermi and multifrequency observations of blazars

The Fermi Gamma-ray Space Telescope was successfully launched on June 11, 2008 and has already opened a new era for gamma-ray astronomy. The Large Area Telescope(LAT), the main instrument on board Fermi, with its large field of view and effective area, combined with its excellent timing capabilities, presents a significant improvement in sensitivity over its predecessor EGRET. The preliminary results of the Spectral Energy Distribution Analysis performed on a sample of bright blazars are presented. We have studied the quasi-simultaneous Spectral Energy Distributions (SED) of 48 blazars, detected within the three months of the Fermi LAT Bright AGN Sample (LBAS) data taking period, combining Fermi and Swift data with radio NIR-Optical and hard-X/gamma-ray data. We have used these SEDs to characterize the peak position and intensity of both the low and the high-energy features of blazar spectra. The results have been used to derive empirical relationships that estimate the position of the two peaks from the broad-band colors, i.e. the radio to optical (alpha{sub ro}) and optical to X-ray (alpha{sub ox}) spectral slopes, and from the gamma-ray spectral index. Our data show that the synchrotron peak frequency is positioned between 10{sup 12.5} and 10{sup 14.5} Hz in FSRQs and between 10{sup 13} and 10{sup 17} Hz in BL Lacertae objects. We find that the gamma-ray spectral slope is strongly correlated with the synchrotron peak energy, as expected at first order in synchrotron--inverse Compton scenarios. However, simple homogeneous, one-zone, Synchrotron Self Compton (SSC) models cannot explain most of our SEDs, especially in the case of FSRQs and low energy peaked (LBL) BL Lacs. More complex models involving External Compton Radiation or multiple SSC components are required to reproduce the overall SEDs and the observed spectral variability.

79 ASTRONOMY AND ASTROPHYSICS↗

Designs and Modeling of Architect Multi-material Scintillator System

We present a new conceptual radiation detector, the Architected Multimaterial Scintillator System, that utilizes a scintillator composed of multiple materials arranged in architected structures to enable new capabilities. By structuring differently-dyed materials, the wavelength of the scintillation light encodes additional information in radiation measurements. These structures can be realized through additive manufacture (3D-printing). Two classes of this concept are described and modelled using Monte Carlo simulations to evaluate their performance. The first detector design uses dye microstructures to encode particle tracking information, allowing for directional neutron detection and gamma/neutron discrimination. The second design uses a dye gradient to indicate the position of radiation along the gradient. The simulation results indicate this new concept in radiation detection can achieve strong performance in a variety of capabilities including particle identification, directionality and spectroscopy measurements, and particle position reconstruction.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗