HTR-PROTEUS Pebble Bed Experimental Program Core 4: Random Packing With a 1:1 Moderator-to-Fuel Pebble Ratio

In its deployment as a pebble bed reactor (PBR) critical facility from 1992 to 1996, the PROTEUS facility was designated as HTR-PROTEUS. This experimental program was performed as part of an International Atomic Energy Agency (IAEA) Coordinated Research Project (CRP) on the Validation of Safety Related Physics Calculations for Low Enriched HTGRs. Within this project, critical experiments were conducted for graphite moderated LEU systems to determine core reactivity, flux and power profiles, reaction-rate ratios, the worth of control rods, both in-core and reflector based, the worth of burnable poisons, kinetic parameters, and the effects of moisture ingress on these parameters. One benchmark experiment was evaluated in this report: Core 4. Core 4 represents the only configuration with random pebble packing in the HTR-PROTEUS series of experiments, and has a moderator-to-fuel pebble ratio of 1:1. Three random configurations were performed. The initial configuration, Core 4.1, was rejected because the method for pebble loading, separate delivery tubes for the moderator and fuel pebbles, may not have been completely random; this core loading was rejected by the experimenters. Cores 4.2 and 4.3 were loaded using a single delivery tube, eliminating the possibility for systematic ordering effects. The second and third cores differed slightly in the quantity of pebbles loaded (40 each of moderator and fuel pebbles), stacked height of the pebbles in the core cavity (0.02 m), withdrawn distance of the stainless steel control rods (20 mm), and withdrawn distance of the autorod (30 mm). The 34 coolant channels in the upper axial reflector and the 33 coolant channels in the lower axial reflector were open. Additionally, the axial graphite fillers used in all other HTR-PROTEUS configurations to create a 12-sided core cavity were not used in the randomly packed cores. Instead, graphite fillers were placed on the cavity floor, creating a funnel-like base, to discourage ordering effects during pebble loading. Core 4 was determined to be acceptable benchmark experiment.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Statistical Coverage Concerns in a Revised k-Effective of the World Problem [Slides]

A revised version of k-Effective of the World is defined specifically to stress current Monte Carlo power iteration techniques. Results of numerous independent Monte Carlo calculations show that even for batch sizes that are typically considered reasonable (5-10K), incorrect results for k are obtained with non-trivial probability. The causes for what makes a problem prone to having these difficulties are identified and advice for criticality safety practitioners is provided.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Critical Configuration and Physics Measurements for Assemblies of U(93.15)O 2 Fuel Rods (1.506-cm Pitch)

A series of critical experiments were completed from 1962–1965 at Oak Ridge National Laboratory’s (ORNL’s) Critical Experiments Facility (CEF) in support of the Medium-Power Reactor Experiments (MPRE) program. In the late 1950s, efforts were made to study “power plants for the production of electrical power in space vehicles.”(a) The MPRE program was a part of those efforts and studied the feasibility of a stainless-steel system, boiling potassium 1 MW(t), or about 140 kW(e), reactor. The program was carried out in [fiscal years] 1964, 1965, and 1966. A summary of the program’s effort was compiled in 1967.a The delayed critical experiments were a mockup of a small, potassium-cooled space power reactor for validation of reactor calculations and reactor physics methods. Initial experiments, performed in November and December of 1962, consisted of a core of unmoderated stainless-steel tubes, each containing 26 UO 2 fuel pellets, surrounded by a graphite reflector. Measurements were performed to determine critical reflector arrangements, relative fission-rate distributions, and cadmium ratio distributions. Subsequent experiments used beryllium reflectors and also measured the reactivity for various materials placed in the core. “The [assemblies were built] on [a] vertical assembly machine so that the movable part was the core and bottom reflector” (see Reference 1). The experiment studied in this evaluation was the second of the series and had the fuel rods in a 1.506-cm-triangular pitch. One critical configuration was found (see Reference 3). Once the critical configuration had been achieved, various measurements of reactivity, relative axial and radial activation rates of 235U,bc and cadmium ratios were performed. The cadmium ratio, reactivity, and activation rate measurements performed on the critical configuration are described in Sections 1.3, 1.4, and 1.7, respectively.

1.506-cm pitch↗

Critical Configuration and Physics Measurements for Beryllium Reflected Assemblies of U(93.15)O 2 Fuel Rods (1.506-cm Pitch)

Cadmium ratios were measured with enriched uranium metal foils at various locations in the assembly with the fuel tube at the 1.506-cm spacing. They are described in the following subsections. The experiment configuration was the same as the first critical configuration described in HEU-COMP-FAST-004 (Case 1). The experimenter placed 0.75-cm-diameter × 0.010-cm-thick 93.15%-235U-enriched uranium metal foils with and without 0.051-cm-thick cadmium covers at various locations in the core and top reflector. One part of the cadmium cover was cupshape and contained the uranium foil. The other part was a lid that fit over the exposed side of the foil when it was in the cup shaped section of the cover. As can be seen in the logbook, two runs were required to obtain all the measurements necessary for the cadmium ratio. The bare foil measurements within the top reflector were run first as part of the axial foil activation measurements. The results of this run are used for both the axial activation results and the cadmium ratios. Cadmium covered foils were then placed at the same location through the top reflector in a different run. Three pairs of bare and cadmium covered foils were also placed through the core tank. One pair was placed at the axial center of a fuel tube 11.35 cm from the center of the core. Two pairs of foils were placed on top of fuel tubes 3.02 and 12.06 cm from the center of the core. The activation of the uranium metal foils was measured after removal from the assembly using two lead shielded NaI scintillation detectors as follows. The NaI scintillators were carefully matched and had detection efficiencies for counting delayed-fission-product gamma rays with energies above 250 KeV within 5%. In all foil activation measurements, one foil at a specific location was used as a normalizing foil to remove the effects of the decay of fission products during the counting measurements with the NaI detectors. The normalization foil was placed on one NaI scintillator and the other foil on the other NaI detector and the activities measured simultaneously. The activation of a particular foil was compared to that of the normalization foil by dividing the count rate for each foil by that of the normalization foil. To correct for the differing efficiencies of the two NaI detectors, the normalization foil was counted in Detector 1 simultaneously with the foil at position x in Detector 2, and then the normalization foil was counted simultaneously in Detector 2 with the foil from position x in Counter 1. The activity of the foil from position x was divided by the activity of the normalization foil counted simultaneously. This resulted in obtaining two values of the ratio that were then averaged. This procedure essentially removed the effect of the differing efficiencies of the two NaI detectors. Differing efficiencies of 10% resulted in errors in the ratios measured to less than 1%. The background counting rates obatined with the foils used for the measurements on the NaI detectors before their irradiation measurement were subtracted from all count rates. The results of the cadmium ratio measurements are given in Table 1.3-1 and Figure 1.3-1. “No correction has been made for self shielding in the foils” (Reference 3).

1.506-cm pitch↗

Quick-Start Guide to Low-Energy Photon/Electron Transport in MCNP6

A new feature of the particle transport code MCNP6 is the ability to transport photons and electrons below the traditional lower energy limit of 1 keV. Full discussions of this new capability, its supporting data, and its methods, especially the new single-event electron transport, a data-based method that replaces condensed-history in selected energy ranges, will appear in various publications in the near future. In this document, we present a few practical points that users of the new feature will need to know.

61 RADIATION PROTECTION AND DOSIMETRY↗

Lawrence Livermore National Laboratory: Laboratory Directed Research and Development (FY2012 Annual Report)

The LDRD annual report for fiscal year 2012 (FY12) provides a summary of LDRD funded projects for the fiscal year and consists of two parts: Overview: A broad description of the LDRD Program, highlights of accomplishments and awards for the year, program statistics, and the LDRD portfolio-management process. Project Summaries: A summary of each project, submitted by the principal investigator. Project summaries include the scope, motivation, goals, relevance to DOE/NNSA and LLNL mission areas, the technical progress achieved in FY12, and a list of publications that resulted from the research.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Bias and Uncertainty Under-Prediction in Monte Carlo Depletion [Slides]

Monte Carlo criticality calculations have well-known issues. – Bias in Results: Arises from renormalization with a small batch size. – Under-prediction of Uncertainties: Criticality calculations do not account for positive correlation between cycles. Previous work has focused on static calculations, no assessment on how depletion calculations are affected.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Flux and Reaction Rate Kernel Density Estimators in OpenMC

Current methods for obtaining flux and reaction rate profiles in a Monte Carlo simulation rely on histogram tallies that can suffer from large uncertainties when fine detail is required. Recently, another density estimation technique has been applied to Monte Carlo radiation transport sim ulations: the Kernel Density Estimator (KDE) [Banerjee, K.]. KDEs are capable of calculating the flux at a point without the necessity of tracking particles on a spatial mesh, making KDEs ideal tools for multi-physics problems. Furthermore, KDEs allow for one collision or track length to contribute to the estimate of the flux at multiple points, circumventing the large statistical uncertainties associated with fine-mesh histogram tallies. However, KDEs have only been proven to be capable of estimating flux values at a series of points; no work has been done to estimate reaction rates or other quantities of interest. Furthermore, little work has been done in optimizing the KDE bandwidth for the energy-dependence of neutron transport simulations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Final report on DOE ASCR Grant DESC0001862 (ER25894)

As was outlined in the proposal, the overall objective of this project is to investigate advanced optimization algorithms for solving entropy maximization problems. Entropy maximization is a general tool for reconstructing the least biased estimate of the state of a complex system, based on available information. In transport and kinetic theory, entropy maximization is used to derive closures for moment models in order to reduce the complexity of a kinetic description while maintaining many of its fundamental features. Application areas include gas dynamics, charged-particle transport, thermal radiative transfer, and neutron transport. Some such applications are of prime importance to the Department of Energy.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Gravity Gradiometry: A Novel Application for Compressed Sensing

During the past decade, compressed sensing (CS) has proven to be extremely useful for sparse signal reconstruction. Here the method of CS is applied to fast mass distribution determination based on cold atom gravity gradiometer measurements. Specifically we consider an array of M gradiometers placed around a 2D target area in order to determine the interior mass distribution in cases where the set of (M) sensor measurements under samples the distribution. This was done by assuming that the system’s sparsity comes from the mass distributions only having K non-zero masses, which led to a non-orthogonal basis dictionary. This lack of orthogonality caused interesting behaviors, including weakened noise performance, and breaking of the typical CS motivated logarithmic scaling of required M values for larger K values. However, for low K values M scaled as expected. Modifications to the gravity sensor model to promote orthogonality and test its impact on signal recovery postponed the onset of anomalous scaling; suggesting that lack of orthogonality is the primary cause. While CS works for this sparse, but intrinsically ill-posed problem, this sensor system displayed increased noise sensitivity and a smaller upper bound on the size of recoverable K sets. However, while these limitations decrease CS performance, significant improvements over traditional sensing approaches are still possible.

74 ATOMIC AND MOLECULAR PHYSICS↗

ORSphere: Critical, Bare, HEU(93.2)-Metal Sphere

In the early 1970’s Dr. John T. Mihalczo (team leader), J.J. Lynn, and J.R. Taylor performed experiments at the Oak Ridge Critical Experiments Facility (ORCEF) with highly enriched uranium (HEU) metal (called Oak Ridge Alloy or ORALLOY) in an attempt to recreate GODIVA I results with greater accuracy than those performed at Los Alamos National Laboratory in the 1950s (HEU-MET-FAST-001). The purpose of the Oak Ridge ORALLOY Sphere (ORSphere) experiments was to estimate the unreflected and unmoderated critical mass of an idealized sphere of uranium metal corrected to a density, purity, and enrichment such that it could be compared with the GODIVA I experiments. “The very accurate description of this sphere, as assembled, establishes it as an ideal benchmark for calculational methods and cross-section data files.” (Reference 1) While performing the ORSphere experiments care was taken to accurately document component dimensions (±0. 0001 in. for non-spherical parts), masses (±0.01 g), and material data The experiment was also set up to minimize the amount of structural material in the sphere proximity. A three part sphere was initially assembled with an average radius of 3.4665 in. and was then machined down to an average radius of 3.4420 in. (3.4425 in. nominal). These two spherical configurations were evaluated and judged to be acceptable benchmark experiments; however, the two experiments are highly correlated.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗