Search NASA⌕ Search

SEARCH · Search NASA

Results for “Sensitivity Matrix”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,783 records · Page 99

Radionuclide Sensors for Environmental Monitoring: From Flow Injection Solid-Phase Absorptiometry to Equilibration-Based Preconcentrating Minicolumn Sensors with Radiometric Detection

The development of in situ sensors for ultratrace detection applications in process control and environmental monitoring remains a significant challenge. Such sensors must meet difficult detection limit requirements while selectively detecting the analyte of interest in complex or otherwise challenging sample matrixes. Nowhere are these requirements more daunting than in the field of radionuclide sensing. The detection limit requirements can be extremely low. Nevertheless, a promising approach to radionuclide sensing based on preconcentrating minicolumn sensors has been developed. In addition, a method of operating such sensors, which we call equilibration-based sensing, has been developed that provides substantial preconcentration and a signal that is proportional to analyte concentration, while eliminating the need for reagents to regenerate the sorbent medium following each measurement. While this equilibration-based sensing method was developed for radionuclide sensing, it can be applied to nonradioactive species as well, given a suitable on-column detection system. By replacing costly sampling and laboratory analysis procedures, in situ sensors could have a significant impact on monitoring and long term stewardship applications. The aim of this review is to cover radionuclide sensors that combine some form of selective sorption with a radiometric detection method, and­as a primary aim­to comprehensively review preconcentrating minicolumn sensors for radionuclide detection. As a secondary aim, we will cover radionuclide sensors that combine sorption and scintillation in formats other than minicolumn sensors. We are particularly concerned with the detection of alpha- and beta-emitting radionuclides, which present particular challenges for measurements in liquid media.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Accelerated panel methods using the fast multipole method

Panel methods are commonly used in computational fluid dynamics for the solution of potential flow problems. The methods are a numerical technique based on the surface distribution of singularity elements. The solution is the process of finding the strength of the singularity elements distributed over the body's surface. This process involves the solution of the matrix problem Pq = p' for a set of unknowns q. The Fast Multipole Method is used to directly compute q without using matrix solvers. The algorithm works in O(N) time for N points, a great improvement over standard matrix solvers. In panel methods, the surface of a body is divided into a series of quadrilateral panels. The methods involve the computation of the influence of all other panels on each individual panel. The influence is based on the surface distribution, though this can be approximated by the area for distant panels. An alternative approximation, though with arbitrary accuracy, is to develop a multipole expansion about the center of the panel to describe the effect of a given panel on distant points in space. The expansion is based on the moments of the panel, thus allow the use of various surface distributions without changing the basic algorithm, just the computation of the various moments. The expansions are then manipulated in a tree walk to develop Taylor series expansions about a point in space which describe the effect of all distant panels on any point within a volume of convergence. The effect of near panels then needs to be computed directly, but the effect of all distant panels can be computed by simply evaluating the resulting expansion. The Fast Multipole Method has been applied to panel methods for the solution of source and doublet distributions. A major feature of the algorithm is that the algorithm does not change to derive the potential and velocity for sources and doublets. The same expansions can be used for both sources and doublets. Since the velocity is related to the potential, and the doublet potential is related to the z-component of the source velocity, all values can be derived from the same expansion by taking a series of partial derivatives. This requires more expansion terms to be kept since terms are lost in the process of taking partial derivatives. Thus to maintain accuracy for the doublet computation, more terms are required than if just evaluating for sources. The resulting Fast Multipole code should then parallelize better than classical panel methods due to the locality of data dependencies found in the Fast Multipole Method. Theoretically the parallelized code should execute in O(log N) time with O(N) processors, though this is not practical. Ongoing work includes implementing the parallel accelerated panel method, including methods to improve the load balancing of the problem by taking advantage of the known geometry of panels, and to encorporate sensitivity analysis into the algorithm.

Leathrum, James F., Jr.↗

Characterization of imaging performance in differential phase contrast CT compared with the conventional CT: Spectrum of noise equivalent quanta NEQ(k)

Purpose: Differential phase contrast CT (DPC-CT) is emerging as a new technology to improve the contrast sensitivity of conventional attenuation-based CT. The noise equivalent quanta as a function over spatial frequency, i.e., the spectrum of noise equivalent quanta NEQ(k), is a decisive indicator of the signal and noise transfer properties of an imaging system. In this work, we derive the functional form of NEQ(k) in DPC-CT. Via system modeling, analysis, and computer simulation, we evaluate and verify the derived NEQ(k) and compare it with that of the conventional attenuation-based CT. Methods: The DPC-CT is implemented with x-ray tube and gratings. The x-ray propagation and data acquisition are modeled and simulated through Fresnel and Fourier analysis. A monochromatic x-ray source (30 keV) is assumed to exclude any system imperfection and interference caused by scatter and beam hardening, while a 360 Degree-Sign full scan is carried out in data acquisition to avoid any weighting scheme that may disrupt noise randomness. Adequate upsampling is implemented to simulate the x-ray beam's propagation through the gratings G{sub 1} and G{sub 2} with periods 8 and 4 {mu}m, respectively, while the intergrating distance is 193.6 mm (1/16 of the Talbot distance). The dimensions of the detector cell for data acquisition are 32 Multiplication-Sign 32, 64 Multiplication-Sign 64, 96 Multiplication-Sign 96, and 128 Multiplication-Sign 128 {mu}m{sup 2}, respectively, corresponding to a 40.96 Multiplication-Sign 40.96 mm{sup 2} field of view in data acquisition. An air phantom is employed to obtain the noise power spectrum NPS(k), spectrum of noise equivalent quanta NEQ(k), and detective quantum efficiency DQE(k). A cylindrical water phantom at 5.1 mm diameter and complex refraction coefficient n= 1 -{delta}+i{beta}= 1 -2.5604 Multiplication-Sign 10{sup -7}+i1.2353 Multiplication-Sign 10{sup -10} is placed in air to measure the edge transfer function, line spread function and then modulation transfer function MTF(k), of both DPC-CT and the conventional attenuation-based CT. The x-ray flux is set at 5 Multiplication-Sign 10{sup 6} photon/cm{sup 2} per projection and observes the Poisson distribution, which is consistent with that of a micro-CT for preclinical applications. Approximately 360 regions, each at 128 Multiplication-Sign 128 matrix, are used to calculate the NPS(k) via 2D Fourier transform, in which adequate zero padding is carried out to avoid aliasing in noise. Results: The preliminary data show that the DPC-CT possesses a signal transfer property [MTF(k)] comparable to that of the conventional attenuation-based CT. Meanwhile, though there exists a radical difference in their noise power spectrum NPS(k) (trait 1/|k| in DPC-CT but |k| in the conventional attenuation-based CT) the NEQ(k) and DQE(k) of DPC-CT and the conventional attenuation-based CT are in principle identical. Conclusions: Under the framework of ideal observer study, the joint signal and noise transfer property NEQ(k) and detective quantum efficiency DQE(k) of DPC-CT are essentially the same as those of the conventional attenuation-based CT. The findings reported in this paper may provide insightful guidelines on the research, development, and performance optimization of DPC-CT for extensive preclinical and clinical applications in the future.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Data-Driven Performance Optimization of Gamma Spectrometers With Many Channels

In gamma spectrometers with variable spectroscopic performance across many channels (e.g., many pixels or voxels), a tradeoff exists between including data from successively worse-performing readout channels and increasing efficiency. Brute-force calculation of the optimal set of included channels is exponentially infeasible as the number of channels grows, and approximate methods are required. In this work, we present a data-driven framework for attempting to find near-optimal sets of included detector channels. The framework leverages non-negative matrix factorization (NMF) to learn the behavior of gamma spectra across the detector and clusters similarly-performing detector channels together. Performance comparisons are then made between spectra with channel clusters removed, which is more feasible than brute force. The framework is general and can be applied to arbitrary, user-defined performance metrics depending on the application. We apply this framework to optimizing gamma spectra measured by H3D M400 CdZnTe (CZT) spectrometers, which exhibit variable performance across their crystal volumes. In particular, we show several examples optimizing various performance metrics for uranium and plutonium gamma spectra in non-destructive assay (NDA) for nuclear safeguards, and explore trends in performance versus parameters such as clustering algorithm type. We also compare the NMF + clustering pipeline to several non-machine-learning (ML) algorithms, including several greedy algorithms. Although, we find that the NMF + clustering pipeline tends to find the best-performing set of detector voxels, significantly improving over the unoptimized spectra, but that a greedy accumulation of spectra segmented by detector depth can, in some cases, give similar performance improvements in much less computation time.

Energy resolution↗

Measurement of CP violation observables and parameters for the decays B{sup {+-}}{yields}DK*{sup {+-}}

We study the decay B{sup -}{yields}DK*{sup -} using a sample of 379x10{sup 6} {upsilon}(4S){yields}BB events collected with the BABAR detector at the PEP-II B factory. We perform a Gronau-London-Wyler analysis where the D meson decays into either a CP-even (CP+) eigenstate (K{sup +}K{sup -}, {pi}{sup +}{pi}{sup -}), CP-odd (CP-) eigenstate (K{sub S}{sup 0}{pi}{sup 0}, K{sub S}{sup 0}{phi}, K{sub S}{sup 0}{omega}) or a non-CP state (K{sup -}{pi}{sup +}). We also analyze D meson decays into K{sup +}{pi}{sup -} from a Cabibbo-favored D{sup 0} decay or doubly suppressed D{sup 0} decay [Atwood-Dunietz-Soni (ADS) analysis]. We measure observables that are sensitive to the Cabibbo-Kobayashi-Maskawa angle {gamma}: the partial-rate charge asymmetries A{sub CP{+-}}, the ratios R{sub CP{+-}} of the B-decay branching fractions in CP{+-} and non-CP decay, the ratio R{sub ADS} of the charge-averaged branching fractions, and the charge asymmetry A{sub ADS} of the ADS decays: A{sub CP+}=0.09{+-}0.13{+-}0.06, A{sub CP-}=-0.23{+-}0.21{+-}0.07, R{sub CP+}=2.17{+-}0.35{+-}0.09, R{sub CP-}=1.03{+-}0.27{+-}0.13, R{sub ADS}=0.066{+-}0.031{+-}0.010, and A{sub ADS}=-0.34{+-}0.43{+-}0.16, where the first uncertainty is statistical and the second is systematic. Combining all the measurements and using a frequentist approach yields the magnitude of the ratio between the Cabibbo-suppressed and favored amplitudes, r{sub B}=0.31 with a one (two) sigma confidence level interval of [0.24, 0.38] ([0.17, 0.43]). The value r{sub B}=0 is excluded at the 3.3 sigma level. A similar analysis excludes values of {gamma} in the intervals [0, 7] deg., [55, 111] deg., and [175, 180] deg. ([85, 99] deg.) at the one (two) sigma confidence level.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Extrapolation of the Rainflow-Counted Load Ranges for Fatigue Assessment of the Wind Turbine's Blades

Wind turbine design standards recommend the use of statistical modeling coupled with extrapolation of the short-term load data to long-term periods for fatigue reliability assessment. However, statistical error and computational expense can limit the accuracy of such approaches. In the case of wind turbine blades, the errors are more significant because of the high material fatigue exponent that makes the damage estimations more sensitive to variations. In addition, due to different excitation sources, the flapwise load range histogram is not unimodal, and thus its statistical modeling is complex. In the present work, we provide three methods for statistical modeling of the flapwise bending moment ranges including a novel approach based on frequency-based separation of the modes. The first two methods are simplified approaches for modeling the most crucial load ranges using unimodal distributions and the third method involves multimodal distribution fitting. The research is based on 3600 10-minute aeroelastic simulations of DTU 10MW case study wind turbine from which a benchmark damage equivalent load (DEL) is calculated. The DEL calculated by each of the three proposed methods is compared to this reference. The results show that the conventional approach based on using 6 seeds as well as using mixture models fitted on the limited data lead to under-conservative results with errors up to 23%. On the other hand, the simplified unimodal approaches provided in this work can provide conservative estimations of the fatigue damage with mean values 5% and 12% higher than the benchmark. However, the variability of the DEL estimates is higher when using unimodal extrapolation of the load ranges, and the data can be conservative by 17.5%. The proposed unimodal fits suggested for modeling and extrapolation of the blade's load ranges provide less errors relatively and most importantly conservative DEL estimations while maintaining computational efficiency.

blade fatigue↗

Additional Trials & Tribulations in Synthesizing a Sulfide Standard

Well-characterized sulfide reference materials that can serve as matrix-matched calibrants for in-situ trace element analyses via laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) remain elusive. Here, we describe the creation an in-house sulfide standard at NASA JSC that will be used to measure siderophile and chalcophile trace elements in low pressure experimental products, specifically pentlandite ([FeNi]9S8) and pyrrhotite ([FeNi]1-xS), as well as natural sulfides in terrestrial and meteoritic mineral assemblages. Recent methods in creating a homogenous sulfide standard include pressed pellets, synthesized chips, or fused glass [e.g. 1-3]. Other studies, however, have had success in forming homogenous FeS standards via synthesization methods [e.g. 4-6]. We present a variation of the method described in [4], in which we create a pyrrhotite standard doped with a variety of trace elements (Zn, As, Se, Mo, Ru, Rh, Pd, Sn, Sb, Te, W, Os, Ir, Pt, Au) at ~10-40 ppm and Cu at ~200 ppm. Sulfide compositions were constructed using Fe and Ni metal and elemental sulfur powders. Trace elements were added to elemental sulfur from Atomic Absorption Spectroscopy (AAS) elemental standards as either nitrate or chloride solutions to prevent oxidation of the metal powders. The dried sulfur mixture was mixed with Fe and Ni powders and mechanically mixed before two aliquots were placed in separate SiO2 tubes. Each tube was held under vacuum for ~30 minutes, sealed under vacuum, and then heated at 800C for 48 hours. Like [4], the synthesis products were composed of pourous sulfide crystals. Major element analyses of both experimental aliquots, collected using an Electron Probe Microanalyser (EPMA), yield indistinguishable major element compositions (uncertainties in 2SE & 2RSE[%]), with an average of 57.90  0.09 (0.16 %), 4.95  0.03 (0.55 %), and 39.70  0.14 (0.34 %), for Fe, Ni, and S, respectively. Trace element data were measured using a Photon Machines 193nm laser ablation system coupled to a Thermo-Scientific Element-XR ICP-MS. Spot sizes were limited to 50 μm due to the porous nature of the sulfide target material. Trace element abundances, normalized to Fe as an internal standard, were also found to be homogenous between the two aliquots, with weighted mean 2RSE (%) values of <3.0 for all trace elements. Synthesized products were re-powdered and absolute concentrations measured via solution ICP-MS. Although the sulfide appears to be homogenous, sintering experiments will be performed to more closely match the standard density to natural sulfides and minimize differences in ablation behavior. Improved density also allows for higher sensitivity (i.e. more compact target material) and larger spot sizes or traverses, as void space is eliminated. Additional major and trace element analyses on the products of the sintering experiments will be undertaken.

Jacob B Setera↗

LET Spectrum Measurements In CR-39 PNTD With AFM

Energetic protons, neutrons, and heavy ions undergoing collisions with target nuclei of varying Z can produce residual heavy recoil fragments via intra-nuclear cascade/evaporation reactions. The particles produced in these non-elastic collisions generally have such extremely short range ({approx}<10 {mu}m) that they cannot be directly observed by conventional detection methods including CR-39 plastic nuclear track detector (PNTD) that has been chemically etched for analysis by standard visible light microscopy. However, high-LET recoil fragments having range on the order of several cell diameters can be produced in tissue during radiotherapy using proton and carbon beams. We have developed a method to analyze short-range, high-LET tracks in CR-39 plastic nuclear track detector (PNTD) using short duration chemical etching ({approx}<1 {mu}m) following by automated atomic force microscope (AFM) scanning. The post-scan data processing used in this work was based on semi-automated matrix analysis opposed to traditional grey-scale image analysis. This method takes advantage of the 3-D data obtained via AFM to achieve robust discrimination of nuclear tracks from other features inherently present in the post-etch detector surface. Through automation of AFM scanning, sufficient AFM scan frames were obtained to attain an LET spectrum spanning the LET range from 200-1500 keV/{mu}m. In addition to our experiments, simulations were carried out with the Monte Carlo transport code, FLUKA. To demonstrate this method, CR-39 PNTD was exposed to the proton therapy beam at Loma Linda University Medical Center (LLUMC) at 60 and 230 MeV. Additionally, detectors were exposed to 1 GeV protons at the NASA Space Radiation Laboratory (NSRL) at Brookhaven National Laboratory (BNL). For these exposures CR-39 PNTD, Al and Cu target foils were used between detector layers.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Rapidly Assessing the Quality of Targeted Proteomics Experiments through Monitoring Stable-Isotope Labeled Standards

Selected reaction monitoring (SRM), also known as multiple reaction monitoring (MRM), is a data acquisition technique used in targeted analysis of molecules, including targeted proteomic studies. It exploits the unique capability of triple-quadrupole (QQQ) mass spectrometers to monitor the predefined precursor and fragment ion pairs of specific molecules of interest throughout a liquid chromatography (LC) elution profile. Compared to shotgun proteomics, targeted proteomics using SRM has high selectivity, high sensitivity, and a wide linear dynamic range,(1-3) which makes it especially useful in the accurate and reproducible quantification of low-abundance proteins in highly complex biological samples. SRM has been widely used in the fields of biomarker discovery,(4-7) analysis of protein post-translational modifications(8) and characterization of biological protein networks.(4,9) In the recent years, multiple technical advances have greatly improved the throughput of SRM analyses, allowing for the quantification of hundreds of peptides in a single analysis.(6,7,10) For example, a single 800-plex SRM assay (e.g., 400 unlabeled and heavy-labeled peptide pairs and 2400 transitions with retention time scheduling) using ultrahigh-performance liquid chromatography (UHPLC) has been developed to quantify proteins in plasma.(11) Advanced labeling techniques utilizing in vitro proteome-assisted MRM for protein absolute quantification (iMPAQT) demonstrated the capability of SRM in genome-wide protein quantification of over 18?000 human proteins.(12) Moreover, the scan speed of QQQ instrumentation has been greatly improved in recent releases of commercial instrumentation. The newly developed TSQ Altis (released in 2017) can scan more than 600 transitions per second, which is 6 times more than a traditional QQQ scan speed of 100 transitions per second. The breadth of measurement enabled by these technological improvements to QQQ mass spectrometry has increased the feasibility and popularity of large scale targeted proteomics studies,(13) a major application of which will be in clinical studies in which up to hundreds of protein candidates need to be quantified in hundreds of clinical specimens.(14) Quantitative accuracy is a primary motivating factor for utilizing a targeted proteomics protocol. The precise and reproducible absolute quantification produced by SRM assays is essential to many clinical and laboratory experiments.(15,16) Because the abundance of an endogenous peptide is calculated from the measurement of the spiked-in reference standard, it is essential to assess the data quality of these references.(17) In early applications of targeted proteomics, when instrument speed greatly limited the number of transitions that could be monitored, much of this quality assessment was done manually. However, recent improvements in instrument performance and experimental design have enabled a dramatic increase in the number of target peptides and associated SRM transitions, which makes manual quality assessment an untenable and laborious task. A variety of computational tools assist in SRM experiment design and data analysis. The first task in creating an SRM experiment is the choice of proteins and representative peptides to monitor. Achieving a reliable protein abundance requires appropriately choosing peptides that have a strong signal and are free from interferences in the biological matrix. Numerous computational tools exist to facilitate assay design by identifying peptides and refining SRM transitions.(18-21) To help share these assays and eliminate time spent designing the same transitions at multiple institutions, community portals have begun to host well-designed and vetted assays.(22-24) Analyzing the experimental data requires significant computational effort to align files across replicates and experimental conditions, pick peaks and produce quantitative values, normalize data and perform statistical tests, etc.(25-27)

Gibbons, Bryson C.↗

IACMI Project 4.2: Thermoplastic Composite Development for Wind Turbine Blades

(Section 5.1) Composites made from Arkema’s Elium® thermoplastic resin and Johns Manville fiberglass were researched during this project for applications in wind blade manufacturing. A techno-economic model was developed to model this wind blade manufacturing process using these materials in place of traditional composites made with thermoset resin. This model was based on manufacturing a 61.5-meter wind blade, which showed a 4.7% reduction in wind blade cost as compared traditional thermoset materials. These cost savings were not from the thermoplastic material costing less than traditional thermoset materials, but rather from decreased capital costs, faster cycle times and reduced energy requirements and labor costs. (Section 5.2) An infusion and curing model was developed for thermoplastic composite wind blades using PAM-RTM. The primary goal was to demonstrate the infusion simulation for the Elium® resin system on a 13-meter wind blade. Additionally, the exotherm temperature was predicted and compared to measurements, which showed model results within 10% of actual measurements. (Section 5.3) Composite laminate panels and composite sandwich panels with a balsa core were produced; specimens were cut and characterized. Similar composite specimens were made with Elium® thermoplastic resin and Hexion thermoset epoxy (RIMR135/RIMH1366) to enable comparisons between these resin systems. The static test methods included: tensile, compression, in-plane shear, interlaminar shear, flexural, sandwich core shear flexure, and single cantilever beam tests for sandwich beams. Fatigue testing at room temperature was completed to composite laminate panels at a stress ratio of R=0.1 and R=10. In addition, fatigue testing to laminate panels was completed at -30°C, and at room temperature after conditioning specimens at 70°C and 90% relative humidity. Overall, mechanical test results from Elium® composites are similar to epoxy composites. (Section 5.4) Elium composite panels were produced with intentional defects such as voids and nonwetting of fibers to begin to understand performance sensitivity to defects. A thermal digital image correlation (TDIC) method provides high spatial resolution strain field at elevated temperatures and can be used to identify defective regions within composite panels. Flexural modulus differences of 21% were seen between defect and non-defect panels. Other Elium® composite panels were forced to be defective by boiling the resin after infusion, which created voids throughout the composite laminate. X-ray computed tomography scanning was used to view the internal structure of the defect panels. Defect panels had a significant reduction in fatigue life as compared to baseline panels produced without intentional defects. (Section 5.5) Lap shear specimens were fabricated to compare the lap shear strength of an off-the-shelf adhesive (Plexus MA590) and two new adhesives developed by Arkema (Bostik SAF30 90 and Bostik SAF30 120). ISO standard 4587:2003 was used to standardize the testing method and sample fabrication. Lap shear specimens were made at 1mm, 3mm, and 10mm thicknesses. The Bostik adhesive lap shear test results were similar to Plexus for all thicknesses. (Section 5.6) Fiber-reinforced polymer (FRP) composites are typically used in high-performance applications (e.g., aerospace), and their expansion into high-volume industries (e.g. consumer automotive and wind turbine blade manufacturer or similar) is hindered by their cost and a lack of efficient manufacturing techniques. Monitoring the curing process of these composites during manufacturing can improve the efficiency of the process, and therefore reduce the manufacturing cost. Cure monitoring techniques were developed that use probabilistic estimation methods and surface temperature measurements made using infrared cameras. These techniques enable real-time monitoring of the infusion process to locate manufacturing flaws, and they can, potentially, estimate residual stresses in the part. Their commercialization will help facilitate expansion of FRP composites in high-volume industries. (Section 5.7) A 13-meter composite wind blade was produced with Elium® resin and Johns Manville fiberglass; this blade was made with VARTM processing similar to how megawatt-scale wind blades are currently manufactured, but no post-mold heating was used for this thermoplastic composite blade. The wind blade underwent full-scale validation for static loading (4-different load orientations) and flapwise fatigue loading to simulate 20-years of operational loads. The thermoplastic composite wind blade withstood the loading without any noted issues and performed similar to results from a previous full-scale validation to an equivalent epoxy composite wind blade produced with the same blade molds. (Section 5.8) A study was conducted to determine the feasibility of recycling composite wind turbine blade components fabricated with glass fiber reinforced Elium® thermoplastic resin. Dissolution, which is a process unique to thermoplastic matrices, allows recovery of both the polymer matrix and full-length glass fibers, while maintaining their stiffness and strength throughout the recovery process. The economics of recycling is favorable if 50% of the glass fiber is recovered and resold for a process of $\$$ 0.28/kg, and 90% of the resin is recovered and resold at a price of $\$$ 2.50/kg.(Section 10) Recommendations are outlined for commercializing thermoplastic resin for composite wind blade production, in addition to recommended areas for future research.

17 WIND ENERGY↗

Modeling Background Attenuation by Sample Matrix in Gamma Spectrometric Analyses

In laboratory gamma spectrometric analyses, the procedures for estimating background usually overestimate it. If an empty container similar to that used to hold samples is measured, it does not consider the background attenuation by sample matrix. If a 'blank' sample is measured, the hypothesis that this sample will be free of radionuclides is generally not true. The activity of this 'blank' sample is frequently sufficient to mask or to overwhelm the effect of attenuation so that the background remains overestimated. In order to overcome this problem, a model was developed to obtain the attenuated background from the spectrum acquired with the empty container. Beyond reasonable hypotheses, the model presumes the knowledge of the linear attenuation coefficient of the samples and its dependence on photon energy and samples densities. An evaluation of the effects of this model on the Lowest Limit of Detection (LLD) is presented for geological samples placed in cylindrical containers that completely cover the top of an HPGe detector that has a 66% relative efficiency. The results are presented for energies in the range of 63 to 2614keV, for sample densities varying from 1.5 to 2.5 g{center_dot}cm{sup -3}, and for the height of the material on the detector of 2 cm and 5 cm. For a sample density of 2.0 g{center_dot}cm{sup -3} and with a 2cm height, the method allowed for a lowering of 3.4% of the LLD for the energy of 1460keV, from {sup 40}K, 3.9% for the energy of 911keV from {sup 228}Ac, 4.5% for the energy of 609keV from {sup 214}Bi, and8.3% for the energy of 92keV from {sup 234}Th. For a sample density of 1.75 g{center_dot}cm{sup -3} and a 5cm height, the method indicates a lowering of 6.5%, 7.4%, 8.3% and 12.9% of the LLD for the same respective energies.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Measurement of CP Violation in B Anti-B Mixing on the Recoil of Partially Reconstructed Anti-B0 to D* L- Anti-Nu/L Using Kaon Tags

After its formulation in 1960's the Standard Model of Fundamental Interactions has gone through an impressive series of successes, begun with the discovery of neutral weak currents [1] and the experimental observations of the massive carriers of weak interactions, the W ± and Z 0 bosons [2], [3]. High precision measurements performed at LEP and SLAC test the validity of the theory to an unprecedented level of accuracy and do not show any significant deviations with respect to the Standard Model predictions. One of the attractive features of the Standard Model is the description of the phenomena which violate the matter-antimatter symmetry (CP), and this violation uniquely depends (in the quark sector) on a weak phase in the matrix describing the couplings among different quark flavors. CP-violation was discovered in 1964 as a tiny effect in the mixing of the K 0 - $\bar{K}$ 0 system [12] but, after a few decades of study of the physics of K mesons, no strong confirmation of the Standard Model can be obtained on the mechanism which generates CP-violation. On the other hand the physics of B mesons is suitable for a pretty large number of measurements which can confirm or disprove this aspect of the theory. The main goal of the BABAR and Belle experiments physics program is to test the description of CP-violation and flavor physics mainly from the decays of B u and B d mesons. Soon after the beginning of data-taking in 1999, CP-violation was discovered in the interference between mixing and decay in the golden channel B 0 → J/Ψ}K 0 [17] [18], while in 2004 a large direct charge asymmetry was observed in the B 0 → K + π - channel [16]. There is a third kind of CP-violation which can be exhibited by the B d - $\bar{B}$ d system, the so called CP-violation in mixing. The Standard Model predicts this asymmetry to be small, possibly out of reach of current experiments, but several New Physics models contain new particles and couplings which can enhance it up to detectable levels. In this thesis we search for CP-violation in B d - $\bar{B}$ d mixing at the BABAR experiment. We reconstruct one of the two B mesons produced at the PEP-II electromagnetic collider using the partial reconstruction technique, while the flavor of the other B is inferred by the charge of a kaon identified among its decay products. Given the smallness of the physical asymmetry we want to measure, a crucial aspect of this analysis is the control of spurious charge asymmetries arising from the interaction of particles with the detector material. We accomplish this by using a control sample of charged kaons on the same data we use in our analysis. After a brief introduction of the theoretical framework and the phenomenology of the decays of B mesons at a B-factory (chapters 1 and 2), we will review in chapter 3 the current experimental results on this topic. We will then describe the characteristics of the collider and the experimental apparatus (chapter 4) used to perform our measurement. The available dataset and the event pre-selection techniques are treated in chapter 5, while the analysis method is discussed in detail in the following one. In chapters 7 and 8 the definitions of the probability density functions used to model each component of our sample are given and then they are tested in samples of simulated data. Toy and reweighted Monte Carlo data are used in chapter 9 to test the sensitivity of our fitting procedure to the physical parameters related to CP violation; chapter 10 discusses the possibility of modeling some of the components of our sample directly on the data. Finally the fit on the real data sample is described in chapter 11 and the treatment of systematic uncertainties is done in chapter 12, while the final result is given in chapter 13.

43 PARTICLE ACCELERATORS↗

Toward a lean analysis for waste to support the decommissioning operation - 15321

All over the world, several nuclear facilities have been shut down few years ago and are now under dismantling or will be dismantled in the future. - Dismantling project takes place according to three major phases: - Study and definition of the dismantling scenario - Dismantling site operations - Decommissioning and final state characterization. Each step is lead in agreement with safety, security and waste management. This requires analytical tools appropriate to the radiological environment and aims. In the field of security, fissile products, explosives... will be researched and quantified while occupational safety requires quantification of radiological, carcinogenic, mutagenic and reprotoxic elements such as As, Se, Cr(IV)... or even asbestos in order to follow more and more strengthened rules. For waste management, radiological and chemical quantification are necessary but must be completed by determining physical and chemical properties such as reactivity, stability or dissolution of the waste... Required level of knowledge, analytical deadline, uncertainties, limits of detection and matrix varieties depend on the decommissioning phase. Setting up a dismantling scenario requires the most possible accurate knowledge of the initial source term present in the facility, in order to establish waste management flow-sheets, define dismantling intervention modes, and prepare the associated safety demonstrations. As history is often not sufficient, in-situ investigations and off-site laboratories are necessary to assign an initial waste and radiological inventory and propose some strategy operations. When a first scenario is chosen, more detailed samplings and analyses are required to fully prepare estimates of waste volumes and categories, and define and validate the waste recovery system that would be used during the dismantling operation. As the definition of the dismantling plan takes shape, data must be more and more accurate and reliable in order to define the waste outlet. The scaling factors for the waste must be defined in order to assure the refunding of the waste. This includes complete characterizations of various matrixes, with high precision, low detection limit in a limited time of few months, as sketchy data could lead to fix inappropriate plan Once site operations begin, it is necessary to control the safety operational conditions and waste production. Measurements requirement is under the safety threshold. Matrixes are often limited to filter. The most important factor is deadline, because operations delay is costly. Finally at the end of dismantling operations, analyses must be performed to demonstrate the successful clean-up of the work site. Analytical methods with low detection limit are required. Thus, characterization appears as a graded and iterative process and is a key issue for decommissioning and dismantling operations in term of efficiency and cost. In order to face this huge analytical demand, a strategy for sampling and characterization must be developed regarding the real needs. On site measurements are usually performed with existing hand-held instruments. A basic first level of knowledge is obtained without delay, feeding the dismantling scenario. On these bases, a sampling strategy permits to select some representative specimens to be more precise, and accurate analysis is performed on off-site laboratories introducing an additional difficulty: the sampling on the site and sub-sampling in the laboratory itself. Whatever the level of sampling, aliquots are small considering the dimension of the dismantling area. This step is crucial. Sampling strategy must be optimized according to objectives (scaling factors measurement, waste level). But in the particular case of high radioactive level waste, due to security manipulation constraints, the number and mass of samples collected are limited. At the opposite for low level waste, large number of samples is collected meaning that large analytical method capacity is necessary. Optimization of the analytical plan is critical. The analytical strategy (including control of sub-sampling, analysis sequence according to analytical capability and performances, especially for pure beta emitters) developed for real case will be detailed. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Longitudinal analysis of host protein serum signatures of treatment and recovery in pulmonary tuberculosis

A better understanding of treatment progression and recovery in pulmonary tuberculosis (TB) infectious disease is crucial. This study analyzed longitudinal serum samples from pulmonary TB patients undergoing interventional treatment to identify surrogate markers for TB-related outcomes. Serum that was collected at baseline and 8, 17, 26, and 52 weeks from 30 TB patients experiencing durable cure were evaluated and compared using a sensitive LC-MS/MS proteomic platform for the detection and quantification of differential host protein signatures relative to timepoint. The global proteome signature was analyzed for statistical differences across the time course and between disease severity and treatment groups. A total of 676 proteins showed differential expression in the serum over these timepoints relative to baseline. Comparisons to understand serum protein dynamics at 8 weeks, treatment endpoints at 17 and 26 weeks, and post-treatment at 52 weeks were performed. The largest protein abundance changes were observed at 8 weeks as the initial effects of antibiotic treatment strongly impacted inflammatory and immune modulated responses. However, the largest number of proteome changes was observed at the end of treatment time points 17 and 26 weeks respectively. Post-treatment 52-week results showed an abatement of differential proteome signatures from end of treatment, though interestingly those proteins uniquely significant at post-treatment were almost exclusively downregulated. Patients were additionally stratified based upon disease severity and compared across all timepoints, identifying 461 discriminating proteome signatures. These proteome signatures collapsed into discrete expression profiles with distinct pathways across immune activation and signaling, hemostasis, and metabolism annotations. Insulin-like growth factor (IGF) and Integrin signaling maintained a severity signature through 52 weeks, implying an intrinsic disease severity signature well into the post-treatment timeframe. Previous proteome studies have primarily focused on the 8-week timepoint in relation to culture conversion status. While this study confirms previous observations, it also highlights some differences. The inclusion of additional end of treatment and post-treatment time points offers a more comprehensive assessment of treatment progression within the serum proteome. Examining the expression dynamics at these later time periods will help in the investigation of relapse patients and has provided indicative markers of response and recovery.

59 BASIC BIOLOGICAL SCIENCES↗

Control-structure-thermal interactions in analysis of lunar telescopes

The lunar telescope project was an excellent model for the CSTI study because a telescope is a very sensitive instrument, and thermal expansion or mechanical vibration of the mirror assemblies will rapidly degrade the resolution of the device. Consequently, the interactions are strongly coupled. The lunar surface experiences very large temperature variations that range from approximately -180 C to over 100 C. Although the optical assemblies of the telescopes will be well insulated, the temperature of the mirrors will inevitably fluctuate in a similar cycle, but of much smaller magnitude. In order to obtain images of high quality and clarity, allowable thermal deformations of any point on a mirror must be less than 1 micron. Initial estimates indicate that this corresponds to a temperature variation of much less than 1 deg through the thickness of the mirror. Therefore, a lunar telescope design will most probably include active thermal control, a means of controlling the shape of the mirrors, or a combination of both systems. Historically, the design of a complex vehicle was primarily a sequential process in which the basic structure was defined without concurrent detailed analyses or other subsystems. The basic configuration was then passed to the different teams responsible for each subsystem, and their task was to produce a workable solution without requiring major alterations to any principal components or subsystems. Consequently, the final design of the vehicle was not always the most efficient, owing to the fact that each subsystem design was partially constrained by the previous work. This procedure was necessary at the time because the analysis process was extremely time-consuming and had to be started over with each significant alteration of the vehicle. With recent advances in the power and capacity of small computers, and the parallel development of powerful software in structural, thermal, and control system analysis, it is now possible to produce very detailed analyses of intermediate designs in a much shorter period of time. The subsystems can thus be designed concurrently, and alterations in the overall design can be quickly adopted into each analysis; the design becomes an iterative process in which it is much easier to experiment with new ideas, configurations, and components. Concurrent engineering has the potential to produce efficient, highly capable designs because the effect of one subystem on another can be assessed in much more detail at a very early point in the program. The research program consisted of several tasks: scale a prototype telescope assembly to a 1 m aperture, develop a model of the telescope assembly by using finite element (FEM) codes that are available on site, determine structural deflections of the mirror surfaces due to the temperature variations, develop a prototype control system to maintain the proper shape of the optical elements, and most important of all, demonstrate the concurrent engineering approach with this example. In addition, the software used for the finite element models and thermal analysis was relatively new within the Program Development Office and had yet to be applied to systems this large or complex; understanding the software and modifying it for use with this project was also required. The I-DEAS software by Structural Dynamics Research Corporation (SDRC) was used to build the finite element models, and TMG developed by Maya Heat Transfer Technologies, Ltd. (which runs as an I-DEAS module) was used for the thermal model calculations. All control system development was accomplished with MATRIX(sub X) by Integrated Systems, Inc.

Thompson, Roger C.↗

Search for the 𝐾 𝐿 → 𝜋 0 ⁢$𝜈⁢\bar{𝜈}$ Decay at the J-PARC KOTO Experiment

We performed a search for the 𝐾 𝐿 → 𝜋 0 ⁢$𝜈⁢\bar{𝜈}$ decay using the data taken in 2021 at the J-PARC KOTO experiment. With newly installed counters and new analysis method, the expected background was suppressed to 0.252 ± 0.055 stat ⁢ $^{+0.052}_{{−0.067^{syst}}}$. With a single event sensitivity of (9.33 ± 0.0⁢6 stat ±0.8⁢4 syst ) × 10 −10 , no events were observed in the signal region. An upper limit on the branching fraction for the decay was set to be 2.2 ×10 −9 at the 90% confidence level (C.L.), which improved the previous upper limit from KOTO by a factor of 1.4. With the same data, a search for 𝐾 𝐿 → 𝜋 0 ⁢𝑋 0 was also performed, where 𝑋 0 is an invisible boson with a mass ranging from 1 to 260 MeV/𝑐 2 . For 𝑋 0 with a mass of 135 MeV/𝑐 2 , an upper limit on the branching fraction of 𝐾 𝐿 → 𝜋 0 ⁢𝑋 0 was set to be 1.6 ×10 −9 at the 90% C.L.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗